APPROVED PLN BLD2024-0336+Building_Elevations+3.12.2024_7.23.22_AM+4120635ABBREVIATIONS GENERAL -LEGEND 0 DIAMETER RTU EQUIPMENT TAG TYPE ABV ABOVE 2 EQUIPMENT TAG NUMBER ACH AIR CHANGES PER HOUR AD ACCESS DOOR 1 DETAIL OR DIAGRAM NUMBER AFF ABOVE FINISHED FLOOR M2.1 SHEET NUMBER WHERE DETAIL SHOWN AFG AVERAGE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY 1 SECTION LETTER AHU AIR HANDLING UNIT M2.1 SHEET NUMBER WHERE SECTION SHOWN AHRI AIR CONDITIONING, HEATING REFRIGERATION INSTITUTE AP ACCESS PANEL Al REVISION CLOUD AND CHRONOLOGICAL NUMBER ARI AMERICAN REFRIGERATION INSTITUTE BHP BRAKE HORSEPOWER DETAIL REFERENCE OUTLINE BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT POINT OF CONNECTION TO EXISTING OR TO BF BELOW FLOOR OTHERS' WORK BOT BOTTOM BTU(H) BRITISH THERMAL UNIT (HOUR) 01 KEY NOTE CALLOUT CD CONDENSATE CFM CUBIC FEET PER MINUTE 1Q PHOTO ID CALLOUT CONN CONNECTION COP COEFFICIENT OF PERFORMANCE WORK TO BE REMOVED DB DRY BULB/DECIBELS BELS HVAC-LEGEND DIBFF DIFFERENTIAL DN DOWN DR DRAIN �► AIR FLOW DIRECTION E EXISTING EA EACH OR EXHAUST AIR SUPPLY OR OSA DUCT SECTION UP, ROUND OR EAT ENTERING AIR TEMPERATURE 0 RECTANGULAR EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO RETURN, RELIEF OR EXHAUST DUCT SECTION UP, EF EXHAUST FAN 0 ROUND OR RECTANGULAR EFF EFFICIENCY EG ELEV EXHAUST GRILLE ELEVATION SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR EQUIP EQUIPMENT ESP EXH EXTERNAL STATIC PRESSURE EXHAUST RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR EXIST EXISTING F FURNACE EXISTING DUCTWORK °F FAHRENHEIT FF FINISHED FLOOR SLSM SOUND LINED SHEET METAL FLA FULL LOAD AMPERAGE FPM FEET PER MINUTE FC FLEXIBLE EQUIPMENT CONNECTION FREQ FREQUENCY FT FOOT OR FEET SFD COMBINATION FIRE AND SMOKE DAMPER G NATURAL GAS HP HORSEPOWER OR HEAT PUMP T FD FIRE DAMPER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR SD SMOKE DAMPER HT HEIGHT HVAC HEATING, VENTILATING, AIR-CONDITIONING EVADE VOLUME DAMPER HZ HERTZ IBC INTERNATIONAL BUILDING CODE M MD MOTORIZED DAMPER ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IFC INTERNATIONAL FIRE CODE TURNING VANES IFGC INTERNATIONAL FUEL GAS CODE IMC INTERNATIONAL MECHANICAL CODE IN INCHES ROUND TO ROUND 45° FITTING IN WG INCHES WATER GAUGE KW K I LOWATT LAT LEAVING AIR TEMPERATURE/LATITUDE SQUARE TO SQUARE 45° FITTING LBS POUNDS LIN FT LINEAR FOOT OR FEET LRA LOCKED ROTOR AMPS SQUARE TO ROUND 45' FITTING MAX MAXIMUM MBH 1,000 BTU PER HOUR MCA MINIMUM CURRENT AMPS VD 45° FITTING FOR DUCTWORK MFR MANUFACTURER MIN MINIMUM GAS PIPING MOCP MAX OVER CURRENT PROTECTION NEC NATIONAL ELECTRICAL CODE Oc CARBON MONOXIDE SENSOR NIC NOT IN CONTRACT NOM NOMINAL O COORDINATED POWER LOCATION OD OUTSIDE DIAMETER/DIMENSION OPTS OPTIONS O REMOTE SENSOR OSA OUTSIDE AIR PH ELEC POWER PHASE (1 0 OR 30) O THERMOSTAT PN PROJECT NORTH (REFERENCE) POC POINT OF CONNECTION PRESS PRESSURE COMMISSIONING PSI POUNDS PER SQUARE INCH RA RETURN AIR OR RELIEF AIR MECHANICAL SYSTEMS RD ROOF DRAIN REF REFERENCE COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT DATA, AS WELL AS RPM REVOLUTIONS PER MINUTE PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE RTU ROOFTOP UNIT OWNER AND MADE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ) SA SUPPLY AIR WITHIN 90 DAYS OF PROJECT COMPLETION AND IN ACCORDANCE WITH 2O15 SEER SEASONAL ENERGY EFFICIENCY RATIO WSEC SECTION C408.1, INCLUDING: SF SUPPLY FAN OR SQUARE FOOT OR FEET SMACNA SHEET METAL NATIONAL ASSOCIATION 1. PRELIMINARY COMMISSIONING REPORT AND OTHER RELATED REPORTS T TON (1 TON = 12,000 BTUH) SUCH AS AIR BALANCING, START-UP AND/OR PRESSURE TESTING DATA. TN TRUE NORTH (REFERENCE) T-STAT THERMOSTAT 2. RECORD DRAWINGS DEPICTING FINAL INSTALLATION CONFIGURATIONS OF TYP TYPICAL SYSTEMS AND EQUIPMENT. U LL ULTRA LOW LEAK DAMPER UNO UNLESS NOTED OTHERWISE 3. OPERATION AND MAINTENANCE EQUIPMENT MANUALS INCLUDING: UPC UNIFORM PLUMBING CODE MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS AND W WATTS/WIDTH/WINDOW OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND SET WB WET BULB POINT INFORMATION, AND A SIMPLE NARRATIVE DESCRIPTION OF EACH WSEC WASHINGTON STATE ENERGY CODE SYSTEM. COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC PROJECT DESCRIPTION THE PROJECT IS A LIKE -FOR -LIKE, ONE (1) SPLIT SYSTEM HEAT PUMP REPLACEMENT FOR A RESIDENTIAL SPACE, WITHIN A THREE-STORY ASSISTED LIVING BUILDING. THE BUILDING IS SITED WITHIN THE CITY OF EDMONDS (JURISDICTION), SNOHOMISH COUNTY, WASHINGTON. MECHANICAL PERMIT: UNDER APPLICATION RELATED ELECTRICAL PERMIT: UNDER SEPARATE PERMIT GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE INSTALLED BY AN LICENSED COMMERCIAL ELECTRICIAN. 4. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2018 WSEC, IBC AND IMC. 5. ALL RIGGING AND LIFTING TO BE COORDINATED WITH THE BUILDING OWNERSHIP AND ANY OTHER CITY AND LOCAL JURISDICTIONS. APPLICABLE CODES 1. 2018 WASHINGTON STATE ENERGY CODE (WAC) CHAPTER 51-11) 2. 2018 INTERNATIONAL BUILDING CODE (WAC CHAPTER 51-50) 3. 2018 INTERNATIONAL MECHANICAL CODE (WAC CHAPTER 51-52) 4. 2018 INTERNATIONAL FUEL GAS CODE (WAC CHAPTER 51-52) 5. 2018 UNIFORM PLUMBING CODE (WAC CHAPTER 51-56) 6. NATIONAL ELECTRICAL CODE (NFPA 70 - WAC CHAPTER 296-46B) CODE COMPLIANCE NOTES 1. PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2018 WSEC SECTION C403.2.4.1.2. CONTROLS SHALL ALSO BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2018 WSEC SECTION C403.2.4.2 (OFF -HOUR CONTROLS). CONTROLS SHALL BE CONFIGURED TO PREVENT SIMULTANEOUS HEATING AND COOLING. 2. REPLACEMENT SPLIT SYSTEM AIR CONDITIONER IS OF THE SAME TYPE AND OUTPUT CAPACITY. 3. THIS PROJECT MEETS THE 2018 WSEC MINIMUM EFFICIENCY REQUIREMENTS FOR COOLING PROVIDED BY ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS PER TABLE C403.2.3(2)A WITH A SEER OF 12.2, WHICH MATCHES THE MINIMUM REQUIREMENT OF 11.2 SEER FOR EQUIPMENT SIZE CATEGORY <65 MBH (UNITARY AIR CONDITIONERS, SPLIT SYSTEM). MECHANICAL SCOPE THE PROJECT IS FOR THE REPLACEMENT OF ONE (1) EXISTING SPLIT SYSTEM HEAT PUMP HVAC UNIT. THE EXISTING SYSTEM HAS REACHED THE END OF IT'S USEFUL LIFE. THE NEW SYSTEM IS THE SAME TYPE AND SAME NOMINAL OUTPUT CAPACITY: 1. DEMO THE (1) OAC-1 EXISTING ROOFTOP HVAC UNIT & HEAT PUMP SERVING ROOM 304. 2. THE REMOVAL AND DISPOSAL OF THE EXISTING UNITS FROM BUILDING SHALL BE IN A LAWFUL MANNER. RECLAIM EXISTING REFRIGERANT PER EPA STANDARDS; R-22 IS EXISTING REFRIGERANT PER EQUIPMENT NAME PLATE DATA. 3. PROVIDE AND INSTALL ONE (1) ROOFTOP HP UNIT & (1) FAN COIL IN PLACE OF THE EXISTING UNITS PER PLAN. NEW EQUIPMENT INCLUDES ELECTRIC DX COOLING, & BASIC ELECTRO-MECHANICAL CONTROLS. 4. DISCONNECT AND RE -CONNECT REPLACEMENT OAC & IFCU TO EXISTING ELECTRICAL SERVICES. RE -USE EXISTING ELECTRICAL DISCONNECT WHERE PRACTICABLE. LINE VOLTAGE WORK SHALL BE BY LICENSED COMMERCIAL ELECTRICIAN (UNDER SEPARATE PERMIT). 5. REUSE EXISTING THERMOSTAT AND CONTROL WIRING. 6. EQUIPMENT AND SYSTEM START-UP, TEST AND BALANCE, PROGRAMMING AND OWNER TRAINING FOR NEW EQUIPMENT, 0&M MANUALS AND RECORD DRAWINGS. 7. THERE IS AN EXISTING ±48" HIGH PERIMETER PARAPET WALL SURROUNDING ALL OF THE MECHANICAL EQUIPMENT ON THE ROOF. NO SCREENING IS NECESSARY. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work MECHANICAL- RTU Address 750 EDMONDS WAY #340 ----------------------------------------- Owner SUNRISE OF EDMONDS Approved Date 03/27/2024 ------------------------- Building Official Eire C'G 4 f PX Permit Number BLD2024-0336 APPROVED PLANS MUST BE VICINITY MAP (BY GOOGLE MAPS, NOT TO SCALE) PROJECT LOCATION - 750 EDMONDS WAY, EDMONDS R ,`' , -{. a y r L »r i W dk 7 4 r T j f r � r - ✓O �� � r - � i� 4rt - SITE MAP (BY GOOGLE MAPS, NOT TO SCALE) r • r Y- lk 4 + dj IL .0 .4-d NORTH N '.,'. 1 - _ •, r _ 1. 'i L ` - .' .. ` /a � �^ Y •��' ` • war. ..�,. -. �� kr_� •� - - y RTH PROJECT LOCATION - (1) ROOFTOP UNIT TO BE REPLACED BUILDING INFORMATION LEGAL DESCRIPTION PROJECT ADDRESS: SUNRISE OF EDMONDS 750 EDMONDS WAY, EDMONDS, WA. 98020-5126 SITE CONTACT: RICHARD (425) 673-9700 PROPERTY OWNER: HCP SUN1 EDMONDS WA LLC., 2235 FARADAY AVE, SUITE #0, CARLSBAD, CA. 92009 TAX PARCEL NUMBER: 27032500306200 CONSTRUCTION TYPES: 11 - 1 HR FULLY SPRINKLERED PRIMARY OCCUPANCIES: CONVALESCENT CENTER ORIGINAL CONSTRUCT: 2004 TOTAL BUILDING AREA: 60,052 SF CLIMATE ZONE: 4C-SNOHOMISH THIS ASSISTED LIVING RESIDENTIAL PROPERTY HAS A SINGLE INSTUTUTIONAL RELATED OCCUPANCY AND BUILDING IDENTIFICATION ASSOCIATED WITH IT. ADDITIONAL PROPERTY AND BUILDING DATA CAN BE FOUND FROM THE CITY OF EDMONDS AND SNOHOMISH COUNTY ASSESSORS MAPS. DRAWING INDEX PAGE # SHEET # SHEET TITLE SCALE 1 MO.1 COVER SHEET, LEGEND AND NOTES N/A 2 MO.2 EQUIPMENT SCHEDULES & DATA N/A 3 MO.3 EQUIPMENT DATA N/A 4 M1.1 ROOF PLAN - MECHANICAL 1/8" = 1'-0" SEC 25 TWP 27 RGE 03 TH PTN SW1/4 SE1 /4 SW1 /4 DAF: BEG SW COR SD SUB;TH N01 *00 36E ALG W LN 60.6FT TH N60*11 41 E 358.30 FT TO SWLY MGN OF SR-104 (EDMONDS WAY) AS CONVD PER DEED REC AF2180193; THS39*05 51 E PLW & 40FT SWLY C/L SR-104 ALG SWLY MGN AS CONVD TO ST OF WA BY DEEDS REC AFN'S 2180193, 2181901 & 2185476 DIST OF 201.69FT TAP OPST HWY ENGR STA 97+85; TH S01 *05 34W ALG SD MGN DIST OF46.49FT TAP 30FT NWLY & OPST HES 0-70; TH N88*29 44W DIST OF 382.17FT TO POB; PER CITY OF EDM LL-2000-134 REC AFN200303175004 APPROVED BY PLANNING Mar 28 2024 Noise generated by mechanical equipment must meet the standards in ECC 5.30 0 4' 8' 16' SCALE: 1/8" = 1'-0" ON CD � F w � C L Z co C m _ N F 0') 00 00 Q z C O O N Qzrn C 0 �N w Q °O U C L u Ln N W C J 2: Z C p W � w UF ` 0 ~ Oz m Q L C �N s o p> 00 0 - UM Z :. �FWASy�^.; 145�� O FGIS PR •p '' O 0000OSaoN000�o0 03- EXPIRES: 1 0/25/24 RECEIVED Mar 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M001 COVER SHEET LEGEND AND NOTES PROJECT NO. 020-092 3/ 11 /24 OUTDOOR HEAT PUMP EQUIP NO. SERM E CONNECTED NOMINAL TOTAL COOLING SEER SOUND ELECTRICAL. DATAIPOWER,ILBS WEIGHT, BASIS OF DESIGN I INDOOR CAPACITY, CAPACITY, VOLTAGE MOCP {1 j (2) (3) (4) UNIT TONS BTUH DBA OHP-304 RM 304 FCU-30 1.5 18,00C 15 233Vi1P 20 71 140 CARRIER 25SCA51SAO03 OHP (1) ARI LISTED WITH STANDARD FEATURES. INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING 304 PROTECTION. FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE AND SAFETY PRESSURE SWFFCHES. IN TAIL RETFRIGERAN T TUBING AND LE NGTH IN STRICT ACCORDANCE WITH MANUFACT U R E RESRECC0MEND ATION . {} WITH FACTORY OPTION! DISCONNECT. () PROVDE ALL REQUIRED ACCESSORIES FOR LONG -LINE AND LOW -AMBIENT APPLICATIONS. (4) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS_ CONTRACTOR TO FIELD COORDINATE ROUTING. HEAT PUMP COIL 1 EQUIP NO. SERVILE COIL CONFGURATION SUPPLY FAIL COOLING CAPACITY. TONS AUX ELEO HEAT K (30 V) ELECTRICAL DATA WEIGHT, LB BASIS OF DESIGN AIRFLOW, CFM ESP, IN VVC MIN OSA (CFM) MOTOR HP VOLTAGE MOCP FCU-804 R 4 304 VERTICAL 600 0.5 75 113 1. _3 1208VIlP 20 120 CARRIER FJ4DN A18L00 NOTES: (1) PROVIDE CONDENSATE DRAIN TO NEAREST APPROVED RECEPTOR. PROVIDE CONDENSATE PUMP IF REQUIRED, Unit Report For 1.5T SS HP -SEER 'roject- Sunrise Edmonds-1,5T SS HIP 05,15�202: :'Fepared B ; Performance Summary For 1.5T SS HP- EER 'roject- Sunrise Edmonds-15T SS HP 0511 2= 'repared By, System Performance system: 25$[:AfFJ40 Actual Gig Airflow' 600,0 CFM System Quantity' 1 Standard Clg Airflow: 600.0 CFM Altitude. 0A ft Total Net Clg Capacity: 17.20 MSH Linear Plpe Length: 0.0 ft Net Sensible Clg Capacity' 13,10 MBH COP @ 47 F: 3.56 Htg HP Cspadty: 17.50 MBH COP @ 17 F: 2.42 Htg HP Integrated Capacity; 17.50 MBH SEER2 @ ARI Conditlons= 14.3 Total System Power. 11,41 kW EER2 @ AR1 Condition$: 12.0 HSPF2 a ARI Conditions: 7.5 System Palrarrreters Outdoor Unit Parameters Indoor Coil Parameters Unit fulode.l; 25SCA Unit Model: FJ4D Outdoor Unit Parameters Indoor Coll Parameters Unit 12E: 1.5 Tans (Size 18) Unit Size: 18,000 St�uh (size 18} Unit tti+lodel; 25SGA!i18A003 Unit Model: F,l4DNXA1 BE00 Voltage: 208l230-1-60 V-Ph-Hz Cabinet Width: TXVI 14 Inches Cabinet Unit Size (Nominal); 1.5 Tons (9izi� 18) Unit Size (Norninal). 18,000 Stuh {Size 18) VOltage: 20S-1-60 V-Ph-Hz Voltage: 2081230-1.-60 'V-Ph-Hz Voltage: 208-1-60 V-Ph-Hz Heating Size; No Heat CIg Ent Air DI3 Ambient: 95.0 OF Ent Air DB: 80.00 OF Ktg Ent Air DS Ambient. 47A °F Ent Air W& 87.00 °F Outdoor Unit Dimensions and Weight Indoor Call Dimensions and Weight Ent Enthalpy' 31,44 BTUilb Unft Length; 31.1875 in Unit Length' 22.0625 in Lvg Air 08: 59.78 OF Unit Width-. 31.1875 in Unit Width; 14.3125 In Lvg Air WB; 58.06 OF Unit Height: 28.6875 in Unit Height: 42,6075 in Lvg Enthalpy, 25.07 BTUIlb Unit Shipping Weight; 174. lb Unit Shipping Weight: 120. 1b Htg Ent Air DB: 70.0 OF Htg Lvg Air DR. 97,1) OF RESIDENTIALAPPLICATIONS Heating Size (Nominal): No Heat This warranty is to the ortgInal (purchasing owner and subsequent owners only to the extent and as taaiad in the warranty Condition& snot Tvlal External Static Pressure: 0.50 in wg Wow The itmlted warranty period In years, deperidIng an the part and the cialmant. Is As shown in thin sable bErlow. Limited Warranty Years Item "Inal Owner _Subsequent Owner Parts 10- or 5 5 Compressor 10' (or 5) 5 "If woPeriy rogI$ter" within 90 days of origIrial installation, olh¢rwise 5 years (except In CaIIfern ta and Quehoc and nth4!r Iudsdiction!� Ihat prohlbit warranty benefits corkditloned on registration). Sae Warranty Conditions below_ OTHERAPPLICATIONS The warranty period Is five (5) years on the compressor. and one (1 ) year on atl ocher parts_ The warranty is the orlginaI owner only arfd is not available for subsequenl owners. Ordering Information Part Number Description QuBtxti Outdoor Unit 25SCA518AO03 25SCA Comfort Single Stage Real Pump with Puron Refrigerant 1.5 Tons Coolin t 15 SEER ARI Conditions Accessorles KAACH1701AAA Crankcase Heater for Outdoor Unit 1 KSAFT0101AAA Evaporator Freeze Thermostat for Outdoor Unit 1 Indoor Coil FJ40NXA18L00 FJ4D Base Series Fan Coil with Puron 18000 BTU Cooling 208l230-1- 64 1 TXVI 14 fnches Cabinet Aluminum Accessories Residential Carrier Products 81dr 1.37 Page ) r,= ' Electrical Data O+jtdoor Electrical Data Indoor Electrical Data Unit Voltage: 20B1230-1-60 V-Ph-Hz Unit Voltage; 208-1-60 V-Ph-Hz Fan Motor FLA: 0.50 Amps Motor HP: 113 HP MCA' 13.4 Amps MotorFLA' 2.9 Amps Max Fuse. 20 Amps Operating Range Mln; 197 V Accessory Electric Heater Data Operating Range Max: 253 V EH Part Nurnber_ KFFEH8401NO3 Compressor RLA: 10.3 Amps Efectric Heater kW; 2.3 kW Compressor LRA; 45.7 Amps For 2 wire operation {single circuit): Heater Amps; 10.7 Amps Heater + Motor MCA: 17 Amps Healer + Motor MOCP: 20 Amps Accessory Voltage' 208-1-60 V-Ph-Hz The Product and Ratings Data In this program is subjec-t to change at any time and wlthout noil ce, Please refer to the latest product literature and the AHRI direMary at www.ahridiredofy,org #or the most up-to-date information. Residential Canter Products Sldr UNIT DATA Page 5 of 11 GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM IS REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING POWER SUPPLY AND DUCTWORK. 4. NEW OUTDOOR HEAT PUMP IS SAME WEIGHT AS EXISTING. Acoustic Summary For 1.5T SS HP -SEER 'roject: Sunrise Edmonds-1.5T SS HP 0511,rd20Z 'repared By; Outdoor Unit Parameters: Unit Model; Unit Size: Variations: 25SCA 1.5 Tans (Size 10) Standard Octave Sand Center Frequeopy, Hz 1 125 1 250 1 500 1 1k tic I 4k I 8k dBA Sound Power dl 70.2 1 66.4 1 65.1 67.4 1 62.8 1 59.2 1 52.5 A -Wei hted Sound Power. dBA I I I I 1 1 71.0 Indoor Gail Parameters: Unil Model: Unit Size - Cabinet Width FJ40 15,000 S#uh (Size 18) TXVI 14 Inches Cabinet Octave Sand Canter Fraquen!cY,Hz 63 125 250 500 1 1 k I 2k I 4k Sound Power.dB 70.8 66.9 62,8 59.6 57.5 55.8 51.8 The Product and Ratings Data in this program is subject to chan9* at any time and wlthout noil crr_ Pteaso refer to the latest producl literature and the AHRI directofy at www_ahridirectary.org for the most up-to-date information, Residential Canter Products I31dr 1.37 Page 6 of 11 111 A •. �F 45976 �O .•` O oo�oF .•c�sTE�?... ��000 ����SOalloaoN00003- EXPIRES: 10/25/24 RECEIVED Mar 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. MOm2 EQUIPMENT SCHEDULES & DATA SHEETS PROJECT NO. 020-092 COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC 0 4' 8' 16' SCALE: 1/8" 3/11/24 Certified Drawing For 1.5T SS HP-EEF Project: Sunrise Edmonds-155T SS HP 05�1512023 Prepared By: H Outdoor Model Unit Model: Unit Size, voilage: SEER. PartNumber: He 019"M I FIELD FOKK 51FOLT EM -5EMIra '[ 2,41 W; 4.14 1 Ir - AIJ J*H js ■E ■kwx onT rltLrF11Ecs :7k?ll C�i- T�#'LOJaa 1 PRE Fd I �jtl•1�} i 41911J 111E C011, K ! !re 11�11 II'IF •- $IiX0011 LINE Ca41-I - Y>� NSF ' Il +�• r rlt)TO a�� 1 ALUM 2rime}Q£ARAMM IDMRvPM UZOF LWT. 4 ' 1124"Addl1 MT. 2. CENTER OF C.RAWRY 111p, E asria�<roworacSOE L�[]4+a11�41rE��36�E,Ar10+'+`A1Ef7ti+'E#+ 114�11 %mm FOR PIEWER .iN3AW 7 SER S 0FL5 frir,TkQk 13 TM I" 4KNIONI OF THE UMT MOOS L KILIMEER 25SCA 1.5 Tons (Slxe 18) 2081230-1-60 V-Ph•Hz 15 25SGA51SA003 Shipping DiirnenBlonS and Weights Outdoor Una! Heaaht 33.94 in I Operating Weight Shipping Welghl Dimensions A 8 C D E F C F# I J 31.19 inj 28.69 in 1 0.63 in 6-56 in 24.79 in 9.13 in 1-13 inj 3,81 OL 14.75 in 15 25 in 13.50 in 140L 170L The Product and Ratings Data In this program Is subject to change at any time and without notice, Please refer to Rho latest pruducl literature and the AHR1 directory at '".ahridirectory-org for the mG&.1 Lap -to -data InfarmrTation- ResIdenftal Carrier Products Bldr 1.37 Page 7 of 11 Certified Drawing For 1.5T SS HP-EER2 Project: Sunrise Edmonds-1.5T SS HP 05115/2023 Prepared By: �crri: 1. =WTE Pik DOII Im WT sM I'm CU91TI 2 Ill 31sasim Atf 1% 11KV mm IGTD Indoor Call Unit Model: Unit size, Voltage: PartNumber., N 11411 Dell $ic 011IAAll- RON, LEFT .' (AS HIPPED) TElultr MI Iti0a D"I Nil I IdIl{' Tlr.l �T�rii I ffl 501, 1 [Jim i! for ? I'lP 5 114' (AS HIPPED] FJ4D 18.000 Btuh (Size 18) 208-1-W V-Ph-H7 rJ4DNXA181-90 SLOPE C011 i11O1 Tie, OWN rI ftQi& 1 P1.111 k4 Ili' 0 1 10i' tEi41G a btli' TIP i 5iC4Apolt till "IMP }ill -4 l Till fiCE-_ - I, Ter. TT IV T1' Olin q PLAZIF li ltraCEiIF I Jlrll* DOWNFLN TTk.i � IELD CONVERTED) HOR11. RIGHT (FIELD CONVERTED) The Product and Ratings Data in this Program is subjectto change at any time and without natlee, Please refer to than latest product literature and the AHRi directory at "'.ahriCIJrectory,orgfor the most up-twdato Informallon- Residential Carrier Products Bldr 1-37 Page 9 of I Certified Drawing For 1.5T SS HP- EER2 Project: Sunrise Edrrlonds-155T SS HP 0511512023 Prepared By: 1LMiT CBkN{CT]4K S]�t:S txT pm 04S a VA �11. 4 a Opr 47s - 7f+' G UP Li44 LP. a0 '14 �l I.P. asi LT r{nalirs.ir War rrT 9 C claolr ■sour■ 1 i Lxa�OOerrw 88�L ■ FiErtYIt k[+11fY }�-� Y[i■5 RiYr44 ■i°riL-Crru e irf• a TTa■� Iwla LI■r UNNUTICY ri■fL merlon LI■t Cumn- iN 11 S' �arurt4r rrk.{!Ys rrriwl ■i ■• 0 idler Afi FRONT Y(EW YTl's "F• {ODIC YCTaL�rL {OYY [T rU1I kQ[Al 8H F81 ch-5 dA NOIit M# 1C+tWe# Indoor Gail Unit Model: FJ4D Unit SixE'i_ 16.000 Btu (Size 18) Voltage, 208-1-60 V-Ph-Hz Cabinet Insulation: TXV1 14 Inches Cabinet ParINLrmber, FJ4DNXA18L00 TOP VIEW 5LOPr[t COS tIL DEIAtL caYFerT,l sortieI1r0�a�,,41 s Llr mE . Sru1s OWC■i IA r$ TIC 1614 In74 NS IV NTr R■OOU4 n■Ir■ PLL v1s"ilms of A *IK11t+ 44t1si w4tO #rLiT +IS MOT CO15 Li y r4 IeYra►klTc 19. "A1 aCOLLS ur;LCW arrL[t■T]A■s mot ;goo IS1JAM rgar J'r 1140 I. Its Y- 17* Iri' 11 nor to ,, fVgLTMIEU. L.o. 1 ' ra Irs{.x aolrur YYE's 1ZLLLi dart Mti 7aor a I.o-r#get IS�j1pFr��L�[ �p pry[ [ Ce6L■rT #ROTE €OIL1EIWF Or4+1 hi row 1 sea- 13 t ■ei•--- -111 !SIDE VIEW r Ira• illlfr +Q n5 and Weights. Heijf t - Width Indoor Coil 42,69 in 14r31 In 22,06 in 120- lb Dimensions A C D E F G F# J 42L69inj 14.31 in 12.44 inj 12.31 ini 10.44 in 18.13 Ini 18.63 in -1 12-00 in The Product and Ratings Data In this program Is subject to change at any time and without natloe. Please refer to the latest product literature and the AHRI direr" at "'.ahrldirectory.org kw the most up-to-date Information. Residential Carrier Products 81dr 1-37 Page 8 of 11 25SCA5 Comfort Series Single -Stage Air Conditioner rAWN 11 f with Purowt - Refrigerant 1.112 To 5 Tans Turn to the exper-ts Product Data :-�U: -'' - Tins =T hm btm desLgied atillany C ar.w's mIl-4mnt depiemuff rPWOUS refanetaar flair pwith Putaat te57ger= prvmaie 2 coilecum of inures un=dwd by Emu oih,et f■ Ay of egop=*a1 NOTE: F lump commaed m Thu 3o4ment am subjto w c5angt al any, aml Always refer ro the AHM daacCory (WurwAtirwia@aOry erg) for da mas c up-w-da ce r2imp mfarm t*L Industry leading Features i Benefits Efficiency 14 3 • 1; a SEER: 110 • 123 EER 7 3 - 2.1 HSPF2 tdepend�u on nn�a uxa and uldow comhu r tran yuTstled; �Gcroru6r tecbna$o�Y tefuruanou sysrM ludao: *Z gaaLi Zc<emrlls gm-sdawe Sound 5osmd In ele as lose n IrP d13A tinlb acc&wTv mmd bUnke[ CCll foo • Sy%mm supporrs ptogsiamibleor snndud Tbl:ea, AT COCO Oil Reliability tialt-�se deple n.r Pumml refs-garmt - Sgall cpmpreaaoT Inu M4 pressure reliefv3pve Loss ofcJtuaTp %%tech • F ilea dtils Ealanred refrq on sp rem for max im,mr rrLabdiry Durability R'aat ol[� pmecocn Package- - Soli& diarble sb w m&lsl cons:xvoa - nense vnm colt ±weed Applications • T cag•lme - lip ur 250 be {76.20 m) Tarsi *gms"altnrltngk up So 200 fees �60 1�6 m) toadlrtim abom tvIpamauar, of up W 20 a C:4.38 m} esapatarac abase coadmias (See Len&s,r Crulde for =e t+ u0ifa>WTW1L ) Lase unbitw tool.* (darer% to O'F -172T) wick approv@d loon smbumtucessa yk#ts Residential Carrier Products Bldr 1-37 Page 10 of 11 UNIT DATA 3VBJECTTO CHAFI'GE VWITHOUT NOTICE • Multi -tap ECM (electronic commutating motor) motors - all sizes • Integrated motor controlsr with 90-sec off TDR function. have replaced integrated circuit board ■ Fire available speed tags to meet a wide range of appIitationr, ` Larger grooved tube, louver" fin coils I • Efficient, quiet, time -tested blower housings and diffuser; Sturdy, drain be oondensate pans I • Cabinet construction features innovations designed t1D prevent cabinet sweating • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements • Super-thlt* R-4,2 insulation with vapor barrier * Pre -painted gatwan¢ed steel cabinet (taupe rrletallkc) • Cabinet air leakage of less then 2% at 0-5 in,W-C- and cabinet air • leakage less than 1-4% at 0-5 in- W,Cr when tested in accordance with ASHRAE 193 WAndard- - • lmtalllatlon-flexit>•le, mtttlpoise units • Horimxtal hanging provisions on cabinet • No tools required to access filter - Newly improved filter rack area filter door insulation w�al�raiwsrlerr I'dron W"Mendhoom added for improved air seal mmobdopwo - Factor7r4nstalled healer packages availtibte on select models (5- through 15 kW) 3- through 313AW accessory heaters • field installed * Factory-aupplied pourer plug Easy p"-4n proysions #or t►eater Installation - Entry options for high and low voltage vAring hook --up Leah -prevent ng sweet connections '°' ` us * Thermostatic expanwri valve. TXV, on all sues * De* nod for manufactured houlaingapplications LIMfrED WARRAIJTY' �+ • 10 year parts to original purchaser upon timely registration. otherwise 5 years ' Far rMJe''TW 3i PXJC*F* yft WWrdM t f rd delAII.. T'41 dC57I1T'alrC *X* W e xUrk *d 7wa d= OP'l"No Cjr Tee EX R W ITAK Residential Carrier Products Bldr 1.37 Page 11 of 11 0 4' 8' 16' SCALE: 1/8" = 1'-01, o E LU C L m (n 00 CS) F CV00 00 -.l- . ry U rn c Z a = � p c o U Lu Q LU LU F C cn U J (n Z C. pLij� W � LU U ` LL H � �~ O a� O 0> 4-0 - < O - Z Oa000a003- 0 EXPIRES: 10/25/24 RECEIVED Mar 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. MOm3i EQUIPMENT DATA SHEETS PROJECT NO. 020-092 COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC 3/11/24 a COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC TN�ROOF PLAN -MECHANICAL SCALE: 1/8" = 1'-0" / / GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM UNITS ARE REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. PLAN NOTES 01 STAGING OF EQUIPMENT AND CRANE LOCATIONS TO BE COORDINATED AND APPROVED PRIOR TO CONSTRUCTION. O2 NEW UNIT SHALL BE INSTALLED IN SAME LOCATION AS EXISTING O3 EXISTING ROOFTOP HVAC EQUIPMENT NOT IN SCOPE OF WORK (EXISTING TO REMAIN). ® NEW OHP-304 REPLACEMENT 1.5—TON UNIT IS THE SAME TYPE, WEIGHT AND OUTPUT CAPACITY AS EXISTING. NO NEW ROOF PENETRATIONS ARE REQUIRED FOR THIS WORK. RE —USE THE EXISTING ELECTRICAL DISCONNECT SWITCH AS APPLICABLE. RE —USE EXISTING CONTROL WIRING. 0 4' 8' 16' I SCALE: 1/8" = 1'-0" 3/11/24 m CN co co 0 LL 75 0 0 w U) z w U_ J � 2`k 3 �L )92