Loading...
APPROVED PLN FIR BLD BLD2022-1067+Site and Architectural Plans+8.9.2022_12.16.10_PM+3040391JURISDICTIONAL APPROVAL: VERIZON SITE NUMBER: VERIZON SITE NAME: SITE TYPE: TOWER HEIGHT: SITE INFORMATION CROWN CASTLE USA INC. N FIRDALE VILLAG/DENTAL SITE NAME: SITE ADDRESS: 10014 238TH STREET SW EDMONDS, WA 98020 COUNTY: SNOHOMISH MAP/PARCEL #: 00165800000100 AREA OF CONSTRUCTION: EXISTING LATITUDE: 47.78305556 / 47° 46' 59.0" N LONGITUDE: -122.36676389 / 122° 22' 0.35" W LAT/LONG TYPE: NAD83 GROUND ELEVATION: 356 FT CURRENT ZONING: BN ZONE JURISDICTION: CITY OF EDMONDS, WA OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: I113 A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: TBD TBD TOWER OWNER: CARRIER/APPLICANT: ELECTRIC PROVIDER: TELCO PROVIDER: MONOPOLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 VERIZON WIRELESS 3245 158TH AVENUE MS 231 BELLEVUE, WA 98008 SNOHOMISH PUD VERIZON TELECOM PROJECT TEAM A&E FIRM: CROWN CASTLE USA INC. 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CRO WNAE.APPROVAL@CROWNCASTLE.COM CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 USA INC. DISTRICT SEATTLE, WA 98109 CONTACTS: TBD - PROJECT MANAGER TBD- CONSTRUCTION MANAGER ALL WORK SUBJECT APPROVED TO FIELD INSPECTION FOR PLANS MUST BE verizon CODE COMPLIANCE i ON JOB SITE 288879 BUSINESS UNIT #: HICKMAN PARK—ALT1 SITE ADDRESS: MONOPOLE COUNTY: 75,-0„ JU ISDICTIO Approved by Fire VERIZON16226428 08/22/2022 AFM kF�tteYeY DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1.1 OVERALL SITE PLAN C-1.2 SITE PLAN C-2 EXISTING & NEW ELEVATION C-3 ANTENNA PLANS & CABLE SCHEDULE C-4 EQUIPMENT SPECS C-5 RFDS C-6 CONFIGURATION DIAGRAM G-1 GROUNDING PLAN G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 1X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK: • REMOVE (6) ANTENNAS • REMOVE (6) DIPLEXERS • REMOVE (3) BIAS-T • INSTALL (9) ANTENNAS • INSTALL (3) RRHS • INSTALL (1) OVP • INSTALL (1) 12X24 HYBRID CABLE • INSTALL (6) TRIPLEXERS • INSTALL (1) VENTED SHROUD GROUND SCOPE OF WORK: • INSTALL (1) OVP NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER APPROVALS APPROVAL SIGNATURE DATE SITE ACQUISITION CONSTRUCTION RADIO MICROWAVE TELCO EQUIPMENT PROJECT ADMINISTRATOR WO ADMINISTRATOR CROWN CASTLE USA INC. SIGNATURE BLOCK APPROVAL SIGNATURE DATE SITE ACQUISITION PLANNER CONSTRUCTION PROJECT MANAGER UTILITY MANAGER LANDLORD I CONTRACTOR PMI REQUIREMENTS 1 PMI ACCESSED AT https://pmi.v smart.com SMART TOOL VENDOR PROJECT NUMBER --- VzW LOCATION CODE (PSLC) 288879 *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT ANALYSIS REPORT 1 MOUNT MODIFICATION REQUIRED N VzW APPROVED SMART KIT VENDORS REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR VzW SMART KIT APPROVED VENDORS 826146 10014 238TH STREET SW EDMONDS, WA 98020 SNOHOMISH CITY OF EDMONDS, WA LOCATION MAP Lynnwood \ Edmonds /% Alderwood Manor ii NJoodway flperwce 1� Mountlake! ah errace tOd I � Q Lake Shoreline /� Forest Park�--Kenmore_ NO SCALE DRIVING DIRECTIONS FROM VERIZON LOCAL OFFICE (3245 158TH AVENUE MS 231, BELLEVUE, WA 98008): HEAD EAST TOWARD 158TH AVE SE, TURN RIGHT ONTO 158TH AVE SE, TURN RIGHT ONTO SE EASTGATE WAY, TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE, KEEP LEFT AND MERGE ONTO 1-90 W, USE THE RIGHT 2 LANES TO TAKE EXIT 2C TO MERGE ONTO I-5 N, TAKE EXIT 177 TO MERGE ONTO WA-104 W/NE 205TH ST/LAKE BALLINGER WAY, MERGE ONTO WA-104 W/NE 205TH ST/LAKE BALLINGER WAY, TURN LEFT ONTO 232ND ST SW, TURN LEFT ONTO 100TH AVE W, TURN RIGHT. APPLICABLE CODES/REFERENCE I DOCUMENTS ALL WORK SHALL BE PERFORMED A THE CURRENT EDITIONS OF THE FC GOVERNING AUTHORITIES. NOTHIr WORK NOT CONFORMING TO THES] CODE TYPE CC BUILDING 201 MECHANICAL 201 ELECTRICAL 202 REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: DATED: MOUNT ANALYSIS: DATED: RFDS REVISION: DATED: ORDER ID: REVISION: RECEIVED 8/9122 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 T r y I o n tom. 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT LREV 0 01/14/22 PIO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 -7/28/22 PRI FINAL AMT OWING C IN THESE TO O CODES: Building Department jF ]&,ork ; ON EFR - CELL MODIFICATI NEC r Address 10014 238TH ST SW ---------------- 9M$RS VERIZON nAv BY-Pffiq ate;-----------08/]8L2U2__ :-------------------- BUilding Official Eris Corfer 'e"UINumber --------------------------- BLD2022-1067 597868 APPROVED BY PLANNING CALL WASHINGTON ONE CALL �A - (800) 424-5555 p Aug 22 2022 CALL 3 WORKING DAYS BEFORE YOU DIG! o wE���� R °�o 52593 q� �SSIONAL� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 1 2 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: JURISDICTIONAL APPROVAL: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI ASSE A10.48 ( LATEST EDITION AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIREDINVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF MOUNTS AND APPURTENANCES " AND LATEST VERSION OF ANSI/ TIA-1019-A-2012 "STANDARD FOR INSTALLATION ALTERATION AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES ORDINANCES AND APPLICABLE REGULATIONS. S. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES, 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNALS REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: VERIZON TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS OR CAN BE EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS MEASUREMENTS AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES RULES REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12, THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE FOUNDATIONS AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 Psf, 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER.................................................................................... 40 ksi #5 BARS AND LARGER...................................................................................... 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ....................... 3" CONCRETE EXPOSED TO EARTH OR WEATHER: 6 BARS AND LARGER.....................................................................................2" # w #5 BARS AND SMALLER....- ............... -................... ___ .......................... 1-1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABAND WALLS......................................................................................... 3/4„ BEAMS AND COLUMNS... 1 -1/2' 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE ILL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. S. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 It OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR SUCH AS METALLIC CONDUITS METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW THWN THWN-2 XHHW XHHW-2 THW THW-2 RHW OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED, 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SCOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TO CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING EMT INTERMEDIATE METAL CONDUIT IMC OR RIGID METAL CONDUIT RMC SHALL BE USED FOR (EMT), ( ), ) EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90. AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND THE NEC. 21, WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22, SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION'TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED ILL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WE OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29, INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW 'VERIZON". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/24OV, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/48OV, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEE (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT CITY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYR TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHRE PROPOSED EXCAVATION ® TEMPORARY SURVEY MARKINGS ®ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS ® POTABLE WATER ®RECLAIMED WATER, IRRIGATION, AND SLURRY LINES ® SEWERS AND DRAIN LINES RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ve o riz n J 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 i� Try Ion 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT ERtVqr�� � (3 r 52593 4 SS%NAL Cs IT IS A VIOLATION OF LAW FOR ANY PERSON, I IT THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. I SHEET NUMBER: REVISION: T-221 � J (E) SHELTER (E) SHELTER 238TH ST SW 1 D G FT] E APPROXIMATE LOCATION OF PROPERTY LINE APN: 00165800000100 (E) 75'-0" MONOPOLE z ZONING: BN ZONE i �I �I 0 O. zl 0 UI 0 x OI al a L-- rF(E) VERIZON PLATFORM oe f } / QUO APPROXIMATE LOCATION OF PROPERTY LINE (E) SHELTER OVERALL SITE PLAN SCALE: 1/16"=1'-0" (FULL SIZE) n\ SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS. CROWN CASTLE USA INC. HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. JURISDICTIONAL APPROVAL: RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q-A A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT p,BERtV4 0 Q 52593 4 SSIGNAL PCs IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEEK TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-1.1[ 2 JURISDICTIONAL APPROVAL: (E) 75'-0" MONOPOLE (N) VERIZON FEEDLINES (1) 12x24 HYBRID CABLE (E) VERIZON FEEDLINES (12) COAX CABLES (E) VERIZON ICE BRIDGE t 12'—O" (E) VERIZON EQUIPMENT PLATFORM NEW VERIZON EQUIPMENT (1) RAYCAP — OVP-12 (E) VERIZON EQUIPMENT ( 6 ) 2212 B13 RRHs (6) 2212 B5 RRHs (3) RPUS 32 B2 RRHs (3) RRUS32 B66A RRHs (12) QBC-67—C—A—P—lSF QUADPLEXERS (E) SHELTER (E) DOOR PAD SITE PLAN �JSCALE: 1/4"=r'-o" (FULL SIZE) n` 4' 3' 2' 1' 0 4' 1/8"=1'-0" (11 x17) \v RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 . . • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/26/22 PRI FINAL AMT p,B � W E�q Q r 52593 q SSIGNALCs IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-1.2 2 / JURISDICTIONAL APPROVAL: TOP OF TOWER MONOPOLE NEW VERIZON EQUIPMENT (E) VERIZON EQUIPMENT TO BE REMOVED (9) ANTENNAS (6) ANTENNAS ELEV. = 75'-0" (1) OVP (6) DIPLEXERS EXISTING ANTENNA TIP HEIGHT (6) TRIPLEXERS (3) BIAS-T ELEV. INSTALLED ON EXISTING MOUNTS = 75'-0" INSTALLED ON EXISTING MOUNTS EXISTING VERIZON RAID CENTER ELEV. = 71'-0" EXISTING VERIZON MCL NEW VERIZON 5'-0"0 VERIZON EQUIPMENT ELEV. = 71'-0" VENTED SHROUD VER20N EOUIPMENT ANTENNA CL: 61'-0" EXISTING ANTENNA TIP HEIGHT h ANTENNA CL: 61'-10" (E) VERIZON EQUIPMENT 71 -0" ELEV. = 65'-0" 70 -5" (3) BIAS-T MOUNT CL: 61'-0" 73'-4" INSTALLED ON EXISTING MOUNTS 71'-0" EXISTING VERIZON RAD CENTER MOUNT CL: 61'-0" ELEV. = 61 •-0" 71'-0" (E) VERIZON EQUIPMENT TO REMAIN EXISTING VERIZON MCL (3) BIAS-T ELEV. = 61'-0" INSTALLED ON EXISTING MOUNTS EXISTING ANTENNA TIP HEIGHT h ELE %55'-0" (E) 75'-0" MONOPOLE (E) VERIZON FEEDLINES TO REMAIN (12) COAX CABLES (7/6") EXISTING NORTH ELEVATION SCALE: NOT TO SCALE 2 FINAL NORTH ELEVATION SCALE: NOT TO SCALE fF TOWER MONOPOLE ELEV. = 75-0" ANTENNA TIP HEIGHT ELEV. = 7I NEW VERIZON RAD CENTER ELEV.- 73'-4" EXISTING VERIZON MCL ELEV. NEW ANTENNA TIP HEIGHT ELEV. = 71'-6" NEW VERIZON RAD CEMER ELEV. = 70'-5" NEW VERIZON OVP ELEV. NEW ANTENNA TIP HEIGHT ELEV. = 64'-10" EXISTING VERIZON MCL ELEV. = 61'-0" NEW VERIZON RAD CEMER ELEV. = 61-10" EXISTING ANTENNA TIP HEIGHT ELEV.=55'-O" (E) 75'-0" MONOPOLE (E) VERIZON FEEDLNES (12) COAX CABLES (7/8") NEW VERIZON FEEDLINE (1) 12X24 HYBRID CABLE RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/26/22 PRI FINAL AMT p,BERtV4 0 (3 r 52593 4 SSIGNALCs IT IS A VIOLATION OF LAW FOR ANY PERSON, IT THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-2 2 J ANTENNA SCHEDULE @ 73'-4" SECTOR POS. TECHNOLOGY RAO CENTER AZIMUTH ANTENNA MANUFACTURER ANTENNA MODEL MECH. TILT ELECT. TILT TOWER MOUNTED EQUIPMENT FEEDLINE TYPE ALPHA Al L—Sub6 73'-4" 30' ERICSSON AIR6449 0' 6' (2) JMA — TBC-67C—A—P-2SF TRIPLEXER HYBRID BETA B1 L—Sub6 73'-4" 150' ERICSSON AIR6449 0' 6' (2) JMA — TBC-67C—A—P-2SF TRIPLEXER COAX GAMMA C1 L—Sub6 73'-4" 270' ERICSSON AIR6449 0' 6' (2) JMA — TBC-67C—A—P-2SF TRIPLEXER COAX ANTENNA SCHEDULE @ 70'-5" SECTOR POS. TECHNOLOGY FAD CENTER AZIMUTH ANTENNA MANUFACTURER ANTENNA MODEL MECH. TILT ELECT. TILT TOWER MOUNTED EQUIPMENT FEEDLINE TYPE ALPHA Al CBRS 70'-5" 30' ERICSSON KRE105281/1 0' 8' (1) ERICSSON — 4408 848 DC(STACKED) COAX BETA B1 CBRS 70'-5" 150' ERICSSON KRE105281/1 0' 8' (1) ERICSSON — 4408 848 DC(STACKED) COAX GAMMA C1 CBRS 70'-5" 270' ERICSSON KRE105281/1 0' 8° (1) RAYCAP — OVP-12 (1) ERICSSON — 4408 848 DC(STACKED) COAX ANTENNA SCHEDULE @ 61'-10" SECTOR POS. TECHNOLOGY RAO CENTER AZIMUTH ANTENNA MANUFACTURER ANTENNA MODEL MECH. TILT ELECT. TILT TOWER MOUNTED EQUIPMENT FEEDLINE TYPE ALPHA Al LTE/AWS/AWS3 61'-10" 30' COMMSCOPE NNH4-656—R6 0' 2' (1) ANTEL BIAS—T — MODEM 200 BIAST COAX BETA B1 LTE/AWS/AWS3 61'-10" 150' COMMSCOPE NNH4-65B—R6 0' 2' (1) ANTEL BIAS—T — MODEM 200 BAST COAX GAMMA C1 LTE/AWS/AWS3 61'-10" 270' COMMSCOPE NNH4-65B—R6 0' 2' (1) ANTEL BIAS—T — MODEM 200 BAST COAX (ALPHA) /330' AZIMUTH (E) 75'-0" MONOPOLE Al (E) VERIZON ANTENNA TO BE REMOVED (3 TOTAL, 1 PER SECTOR)(GAMMA) C1270' AZIMUTHl \\\ (BETA) 150' AZIMUTH (E) 75'-0" MONOPOLE (E) VERIZON ANTENNA TO BE REMOVED (3 TOTAL, 1 PER SECTOR) (GAM 270' A: @ 71'-0" AGL (ALPHA) 30' AZIMUTH (BETA) 150' AZIMUTH @ 61'-0" AGL ANTENNA AND CABLE SCHEDULE SCALE: NOT TO SCALE (ALPHA) (E) 75'-0" MONOPOLE / 30' AZIMUTH NEW VERIZON ANTENNA (3 TOTAL, 1 PER SECTOR) (GAMMA) 270' AZIMUTH I NEW VERIZON 5'-0"0 VENTED SHROUD (1 TOTAL) NEW VERIZON TRIPLEXER (6 TOTAL, 2 PER SECTOR) Al \ C1 0 I 61 /(BETA) 150' AZIMUTH/ @ 73'-4" AGL (E) 75'-0" MONOPOLE NEW VERIZON OVP-12 I (1 TOTAL I I 1 I NEW VERIZON 5'-0"0 / VENTED SHROUD (1 TOTAL) \ @ 67'-6" AGL CABLE SCHEDULE STATUS CABLE TYPE SIZE QUANTITY EXISTING COAX 7/8" 12 NEW HYBRID 12X24 1 FINAL CABLE QUANTITY 13 (E) 75'-0" MONOPOLE (ALPHA) \ NEW VERIZON ANTENNA / 30' AZIMUTH \ (3 TOTAL, 1 PER SECTOR) / Al \ I(GAMMA) C1 0 I �I 270' AZIMUTH Bi NEW VERIZON RRH 150' (BETA) / AZIMUTH (3 TOTAL, 1 PER SECTOR) NEW VERIZON 5'-0"0 \ VENTED SHROUD 0 TOTAL) @ 70'-5" AGL I / (ALPHA) (E) 75'-0" MONOPOLE / 30° AZIMUTH / Al \ NEW VERIZON ANTENNA \ (3 TOTAL, 1 PER SECTOR) I (GAMMA) C1 O �— 270' AZIMUTH I I B1 / NEW VERIZON 5'-0"0 \ (BETA) VENTED SHROUD 150' AZIMUTH (1 TOTAL) (E) BIAS—T (3 TOTAL, 1 PER SECTOR) @ 61'-10" AGL JURISDICTIONAL APPROVAL: RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonN/ 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT ERtVqr�� � (3 r 52593 q S`SIGNALCs IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. —14 SHEET NUMBER: REVISION: EXISTING ANTENNA PLAN FINAL ANTENNA PLAN 2 SCALE: NOT TO SCALE N 3 SCALE: NOT TO SCALE NC-3 2 JURISDICTIONAL APPROVAL: MANUFACTURER:ERICSSON MODEL: AIR6449 WEIGHT: 81.6 LBS DIMENSIONS: 30.4" X 15.9" X 8.1" FREQUENCY: REFER TO RF DATA SHEET FRONT SIDE ERICSSON AIR6449 I SCALE: NOT TO SCALE 141i1151IAj1-1K919=041dil1I401*4d»1.3 Specifications Documents General Specifications Dimensions (L x W It H) 35in. x 21in. x 18in. Weight 45.15 Ibs ,--,� RAYCAP — RCMDC-6627—PF-48 Q SCALE: NOT TO SCALE MANUFACTURER:ERICSSON MODEL: KRE_105 281 /1 WEIGHT: 1.8 LBS DIMENSIONS: 8" X 8" X 1" 0 eo TOP 8.0" FRONT SIDE ,/'�ERICSSON KRE105281/1 WITH 4408 B48 L SCALE: NOT TO SCALE TBC-67C-A-P-W Tri-band combiner (LOW,AWS,PCS) 550-894119001A WS (A WS-3 compatible) DCIAISG sensing Twin unit 4.3-10 connectors nwAv • Combines 3 wireless bands: AWS. PCS 1900, and all low -band wireless frequencies including 6001MHz spectrum • Very low insertion loss and high isolation for optimized system performance • Automatic DC sense for easy installation and site evolution • Industry -leading connector technology for lasting performance • Compatible with JMA WPS weatherproofing solution Mechanical speciflutions Connectors RF Ground swd Connectors quantity Dimenswr5, extluomg orazkel5 and connectors L.wxHmmUn.) 4.3-10IF) e 189 x 184 x!D(7.72 x 771 x 3.15) Weg6c k9 Ob.) 15.1(11.19) M-1l PoleMall hacker stypked. inciWing two meal clamps fw 45-17a min diameter poles �-�ERICSSON KRE105281/1 WITH 4408 B48 �,SCALE: NOT TO SCALE MANUFACTURER: COMMSCOPE MODEL NO.: NNH4-65B-R6 DIMENSIONS: TOTAL WEIGHT: H 72" W 19.6" 83.114 LBS D 7.8" TOP VIEW FRONT VIEW � COMMSCOPE — NNH4-65B—R6 `� SCALE: NOT TO SCALE MOUNTING BRACKET (SUPPLIED W/ ANTENNA) ANTENNA MOUNTING PIPE INSTALLER NOTE: 1. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS NOTED OTHERWISE. ��ANTENNA MOUNTING DETAIL � SCALE: NOT TO SCALE NEW ANTENNA RACKET V/ ANTENNA) SIDE VIEW RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCASTLE CROWN 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 4 • Try Ion 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT Gyp P,BERtV4 O a r 52593 q o� ��OISTEtt"" SSfONALCs IT IS A VIOLATION OF LAW FOR ANY PERSON, IT THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SHEET NUMBER: 14 REVISION: C-4 2 JURISDICTIONAL APPROVAL: 1 Antenna Summary Added 700 850 1900 AWS AWS3 CRRS L-Sub6 Make Model Centerline Tip Height Azimuth RET 4xRx Imt. Type Quantity ItemID 30(0001) 3D(01) COMMSCOPE NNH 4-658-R6 61.9 64.8 150(0002)150(02) false false PHYSICAL 3 270(0003) 270(03) 30(0001) 5G ERICSSON AIR6449 73.3 74.6 150(0002) false false PHYSICAL 3 270(0003) 150(DI) E ERICSSON KRE105281/1 70.4 70.7 270105) false false PHYSICAL 3 30(09) Removed 700 650 1900 AWS AWS3 CBRS L-Sub6 Make LTE AMPHENOL LTE LTE AMPHENOL Retained 700 B50 1900 AWS AWS3 CRRS L-Sub6 Make Model Centerline Tip Height Azimuth CWx063x19x00-T00- 30(01) 1900-(+45) 61 64.1 150(02) 270(03) CWX063X19X00-TOO- 31)(01) 21004-45) 71 74.1 150(02) 270(03) Model Centerline Tip Height Azimuth No data available. Added:9 Removed:6 Equipment Summary Added Equipment Type Location 700 850 1900 AWS AWS3 CBRS L-Sub6 Make Model RRU Tower LTE Ericsson 4408 B48 DC Hybrid Cable Tower Hybrid Cable 12x24 Triplexer Tower JMAWIRELESS TBC-67C-A-P-2SF OVP Box Tower RAYCAP OVP-12 OVP Box Shelter RAYCAP OVP-12 Removed Equipment Type Location 700 850 1900 AWS AWS3 CBRS L-Sub6 Make Model Diplexer Tower N/A DBC-67C-U-2SF BAST Tower N/A MODEM 200 Retained Equipment Type Location 700 850 1900 AWS AWS3 CBRS L-Sub6 Make Model Coaxial Cables Tower N/A 718" BAIST Tower N/A MODEM 200 RRU Shelter LTE Ericsson 2212 B13 RRU Shelter LTE Ericsson 2212 135 50 RRU Shelter LTE Ericsson RRUS32 B2 RRU Shelter LTE LTE Ericsson RRUS32 B66A Quadplexer Shelter JMAWIRELESS OBC 67-C-A-P-1SF RET 4xRx Inst. Type Quantity Item ID false false PHYSICAL 3 false false PHYSICAL 3 RET 4xRx Imt. Type Quantity Item ID :TSF.11i6T.ltl Cable Length Cable Size Install Type Quantity Item ID PHYSICAL 3 KRG161746/1 , PHYSICAL 1 PHYSICAL 6 PHYSICAL 1 PHYSICAL 1 Cable Length Cable Sizo Install Type Quantity Item ID PHYSICAL 6 PHYSICAL 3 Cable Length Cable Size Install Type Quantity Item ID PHYSICAL 12 PHYSICAL 3 PHYSICAL 6 PHYSICAL 6 PHYSICAL 3 PHYSICAL 3 PHYSICAL 12 RFDS SCALE: NOT TO SCALE RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE NIS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTTON DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT O �E�q Q d¢ 52593 q� O,o FcrsTa$� �SSIONALE�� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-5 2 JURISDICTIONAL APPROVAL: SECTOR 1 D[ e•me •M rauun• agciiutiana Irpu1 aonaoe, ocv ma. DC WWI mono amps C=PauoSly AEG Trlpb-- eoao111(aanblt•d Oc m 530-mo, 650. Aws, o.PCB pan lh- also)1 P. R DC Oa)at16o Pod P�ItY (Dc m mullple WPA Pa11s) Tdolaosa," lop stall DC an CAM 43@da6 Bmareman ar pan is anMSG ocrlrn 16.23J 1149m 2�L eat Aav p.,A to3%[Ulpmll 120 port& to �lLl polt2 IID B13 83 '_1 1a 16Bl4 ; p-IID m20 p— D Sm4.d•h. IO :D p.„E is art a F --------------------------------------- rem Aea• 360 OCJYSGca.1laEa t0 cord Or• Dart x saleaa0. Sae Par p My WloB, Pt Al ,P2600-7M P3 PC3 5—GA.—SG rouled le port—T. MSG De — One oon a 4aeatep. see Port pDaPY— RAFF me M%f12I AB\1' o XMIJ 1 1 10 Bfllpv A U0 15 ADO Ap6 3 Lma Rne 1� IJ 13 850 opM 2 to BBIP.a8 120 12 1001— 9 ID 9 t30bn. '.RBl Pmt[ 120 '00 P— LAB- '3 6 8 0lamm4 SECTOR 2 AVYJ-w ---- banD mA CBRS------Band48 LAA------$and 46 RET N me The RET (AISG) signal All be provided by the 4449 RFI AISG port' A, marked by orange color. The 75OM50 diplexers and 700/PCSIAM tdpLxers should pass he AISG signal via through bias-T module and AISG cable b AISG "IN" condor al the boDam 41i thP_ableooa------- SECTOR 3 intenna • • ., � .. - Est. � �x„ A6f. � N b.... ■ �Q ;� • . 6 s A i O 'al LIB 4a•2a1.•u .�,. 4tilR1.1. R, a P8 • ® 4 • iron bas-T ----------------------------------------- •nchas I Cells Bill ABW cord con[ port A A115Mph. 80 4 see colt 1 see cants i 6UW4-3-2 V�01 Pon B PCS.lpka 80 4 1 Asw 2R I 066 e2LS6 port C LS6 Aph. CPRI I 0 0 #DNlol i 4O 25 ( Y t0 3$ to 20 u t0100 Ixat D I. atpk. CPR: 0 O #On/!0: 1 BandRidth 20 20 100 ponE Atcs h3. 80 4 see cord 1 sae Conti Tx or Rx 3 5 at. 80 pun F PCs b 4 1 1 80 3 1 port G LS6beb CPR]I 0 0 #DrVIDI 40 2.3 port H 856Qa CPM 0 0 Iawtol 1 pod J AWS p— 80 4 see corn 1 sae cant! ao 5 i pod K PCs S— 80 4 1 ! 11 231 port L L56 pmm. CPRD 0 0 #DN/01 ! CONFIGURATION DIAGRAM SCALE: NOT TO SCALE 95MOMI-I-y-2: is Cells sappoftM4406 supports up to 6 ce115. reMB,er design to 3 �Brenches ,C mi-t -z Boa u to 100 BandwiApl MHzI 00 Tx ar Po[ 4 port A port B CBas node) 240 12 port C de CBRSm2 240 12 pod D port E Cull node 3 240 12 pod F 240 12 Pon G pod H 240 12 P. rt 3 240 12 port K port L P. d U port N port P RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • • •; Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 1 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/26/22 PRI FINAL AMT p,BERtV4 0 O r 525933 q `r�iilsTiY'" sSfONAL� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIR! OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-6 1 2 JURISDICTIONAL APPROVAL: / / I� (GAMMA) 270, AZIMUTH Cl I 11 I I I 11 GROUNDING LEGEND #6 STRANDED & INSULATED • • • • • • GROUND BUS BAR MECHANICAL CONNECTION (BETA) / 150' AZIMUTH NEW SECTOR GROUND BAR (TYR) NEW #6 GROUND FROM EQUIPMENT TO GROUND BAR (TYP) NEW #6 GROUND FROM EQUIPMENT TO GROUND BAR (TYR) NEW SECTOR GROUND BAR (NP) ANTENNA GROUNDING PLAN SCALE: NOT TO SCALE / / I(GAMMA) 270' AZIMUTH 11 / (ALPHA) I c1 (GAMMA) 270' AZIMUTH \ \ 150° AZIMUUTH / i NEW SECTOR GROUND BAR (TYR) NEW #6 GROUND FROM EQUIPMENT TO GROUND BAR (TYP) NEW SECTOR GROUND BAR (TYP) NEW #6 GROUND FROM EQUIPMENT TO GROUND BAR (TYR) RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q-A A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT GS'� p,BERtV4 p (3 r is re3R� sSfONAL� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-1 1 2 TO ANTENNA COAX TO ANTENNA COAX T/FINISH GRADE 8" PVC PLUG /--- 8" PVC PLUG CPLG. (THRD.) JURISDICTIONAL APPROVAL: COPPER/GALVANIZED GROUND BAR 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000000000000 �000 0000000000000000@ TWO HOLE LONG BARREL COMPRESSION LUG (TYP) NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. �� ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOT TO SCALE TO TOWER MOUNTED EQUIPMENT (TYP) TO ANTENNA — STANDARD COAX — CABLE GROUND KIT (TYP) #6 STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION (OR AS PROVIDED WITH GROUND KIT) (TYP) COAX CABLE (TYP FOR ALL) TO BTS EQUIPMENT VIA TRAY OR ICE BRIDGE MONOPOLE CL ANTENNA GROUND BAR LOCATED AT MCL (BONDED TO TOWER STEEL) 2 HOLE LUG (TYP) MECHANICAL CONNECTION (TYP) COAX GROUND BAR WITH INSULATORS, CONNECTED DIRECTLY TO THE BOTTOM OF MONOPOLE. SEE NOTE 1 2/0 TINNED BARE COPPER WIRE MONOPOLE PIER GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 \ INSPECTION WELL it EXOTHERMIC WELD (TYP) NOTES: 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. 4SCALETYPICAL ANTENNA CABLE GROUNDING : NOT TO SCALE COPPER/GALVANIZED GROUND BAR O O 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0000000000000 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Q 02 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER TWO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYP. FOR (T,P) BOTTOM GROUND BAR ONLY) NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. --\ TOWER/SHELTER GROUND BAR DETAIL L SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYP) STAINLESS STEEL FLAT WASHER 2-HOLE CRIMP/ (TYP) COMPRESSION CONNECTOR GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYP) BELLVILLE WASHER AW STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYP) STEEL 2-HOLE CRIMP/ COMPRESSION J::�— STAINLESS STEEL CONNECTOR FLAT WASHER (T P) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYP) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF -DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYP) (TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS 5SCAHARDWARE DETAIL FOR EXTERIOR CONNECTIONS LE: NOT TO SCALE w 0 0 z 0 EXOTHERMIC WELD SUBGRADE #2 SOLID (TEST LOOP) — NOTCH SIDES OF 8" PVC SON 40 PIPE TO ALLOW EXIT/ENTRANCE OF GROUND RING WIRE II I hLII— TRENCH BOTTOM 2/0 TINNED CU EXTERNAL CADWELD TEST LOOP TO TOWER GROUND RING WIRE GROUND RING WIRE NOTES: 5/8" 4 x 10'-0" LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) ��� INSPECTION WELL DETAIL `� SCALE: NOT TO SCALE 6" WIDE METALLIC HTEL GRADE WARNING/LOCATOR TAPE AT 12' DEPTH N 0 z z EXOTHERMIC WELD 0 w GROUND RING #2 COPPER WIRE SOLID, TINNED FOR CARRIER AND ICE BRIDGE GROUND LOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 4 x 10'-0" LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) 6 GROUND ROD DETAIL SCALE: NOT TO SCALE RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 2888791 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT p,BERtV4 0 52593 q o ISTER"" SSIGNALCs IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: 14 REVISION: G-212 WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 INC S 2 BOLT TYPE HIS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 INC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" - 16 INC S 2 BOLT #2/0 AWG STRANDED #4/0 AWG STRANDED YA26-2TC38 3/8" - 16 INC S 2 BOLT YA28-2N 1/2" - 16 INC S 2 BOLT TYPE W TYPE VN TYPE NC TYPE SS TYPE GR BURNDY GROUND LUG W/ LONG BARREL (SEE CHART) HEAT SHRINK `(CLEAR) NUT*ARBOLT GROUNDING VVV (TYP)CONDUCTOR LOCK WA TYPE VS TYPE VB TYPE PT TYPE GT' r:"" NOTE: GROUN1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC ART) MOLDS TO BE USED FOR THIS PROJECT. (TYP) 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. BURNDY TWO HOLE LUG W/ LONG BARREL (SEE CHART) CADWELD GROUNDING CONNECTIONS 1 BARE WIRE TO BE SCALE: NOT TO SCALE NO-OX AT BOTH ENDS (TYPICALLY) 12' TO 24" 120" MAX. 1 #6 AWG STRANDED COPPER GROUND WIRE < (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 No CABLE GROUND KIT CABLE CONNECTOR NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. (,--,-,,CABLE GROUND KIT CONNECTION SCALE: NOT TO SCALE 3/8-11x1" TAMPER RESISTANT BOLT (TYR) INSULATORS SEE NOTE 2. (TYP) TO ANTENNAS COAX JUMPER (TYF CONN WEATHERPROOFIf (TYP. SEE N( ANTENNA TO BTS EQUIPMENT NOTES STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) WEATHERPROOFING KIT (TYR) NOTES: GROUND KIT 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. (TYR) ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. N AWG MECHANICAL LUG CONNECTION 2 COPPER/GALVANIZED SCALE' NOT TO SCALE COAX GROUND BAR 3ONDED DIRECTLY TOWER 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. ,/-�GROUND CABLE CONNECTION � SCALE: NOT TO SCALE WALL BRACKET (TYR) ® ® NOTE: MINIMUM OF S/S NUT ® ® 3 THREADS TO BE (TYP) 0 0 0 ® VISIBLE ® ® S/S SPLIT ® 0 2 HOLE LONG WASHER ® ® BARREL TINNED (TYR) UNIVERSAL COPPER SOLID COPPER J0 GROUND BAR (4"x20") LUG S/S FLAT LOCK WASHER ® (TYP) WASHER P/N M10 (TYR) (TYP) TWO -HOLE COMPRESSION LUG NOTES 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY OAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL 6 SCALE: NOT TO SCALE TIN COATED SOLID COPPER BUS BAR S/S FLAT WASHER CHERRY INSULATOR (TYR) INSTALLED IF REQUIRED S/S BOLT (TYR) 7 LUG DETAIL SCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. BRIDGE, OR ON ANTENNA TON *TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING ���GROUNDWIRE INSTALLATION `� SCALE: NOT TO SCALE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. CADWELD (TYP) TIE INTO EXISTING GROUND RII' 8 LE: TRANSITION ING GROUND DETAIL SCANOT TO SCALE PE GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER JURISDICTIONAL APPROVAL: RECEIVED 8/9/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT verizonv 3245 158TH AVENUE MS 231 BELLEVUE WA 98008 Co-f"%CROWN v CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 • Trylon 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 288879 1 BU #: 826146 N FIRDALE VILLAG/DENTAL 10014 238TH STREET SW EDMONDS, WA 98020 EXISTING 75'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 12/15/21 JAM PRELIMINARY AMT 0 01/14/22 PJO FINAL AMT 1 03/11/22 JAM FINAL AMT 2 07/28/22 PRI FINAL AMT p,BERtV4 0 (3 r 52593 q o� ��f37STE� sSfONAL� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIR! OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: G-312 14 REVISION: