SEE REV1 REVIEWED-RESUB 1 BLD2023-0247+Structural_Analysis_or_Calculations+3.24.2023_8.01.34_AM+3440721RESUB RIGHT Mar 24 2023 BLD2023-0247 engineer s CITY OF EDMONDS......................... ....................... DEVELOPMENT SERVICES REVIEWED DEPARTMENT BY Las Vegas CITY OF EDMONDS 1645 Village Center Cir. Suite 10 BUILDING DEPARTMENT' Las Vegas, NV 89134 702.933.7000 NV@wrightengineers.com wrightengineers.com STRUCTURAL CALCULATIONS PROJECT: KAPPEN REMODEL 22317 93rd PL WEST EDMONDS, WA 98020 PROJECT No: SNL2301 19 CLIENT: SMITH CO. PREPARED BY: EA DATE: March 23, 2023 SHEET INDEX BASIS FOR DESIGN DESIGN LOADS GRAVITY ANALYSIS ENGINEERED These calculations are the sole property of WRIGHT ENGINEERS and :_' ............................... may not be reproduced in whole or part without written permission. ................................. . Calculations are valid only for the above named project and are not IN THE USA valid unless engineer's authorized seal and signature are affixed. 1 2 4 RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BASIS FOR DESIGN RIGHT STRUCTURAL ENGINEERS 1.1 BUILDING CODE: INTERNATIONAL BUILDING CODE 2018 1.2 ROOF LIVE LOAD: 20 PSF (REDUCIBLE) 1.3 FLOOR LIVE LOAD: 40 PSF TYP. FLOOR AND DECK 60 PSF CANTILEVERED BALCONY OR DECK 1.4 WIND LOAD: 98 MPH BASIC WIND SPEED IMPORTANCE FACTOR, Iw = 1.0 EXPOSURE B 1.5 SEISMIC LOAD: SEISMIC DESIGN CATEGORY D IMPORTANCE FACTOR, IE = 1.0 SITE CLASS D 1.6 SNOW LOAD: 25 PSF 2.1 FOUNDATION: DESIGNED PER RECOMMENDATIONS BY INTERNATIONAL BUILDING CODE 2018 CODE MINIMUMS. ALL FOOTINGS SHALL EXTEND A MINIMUM OF 18 INCHES BELOW PAD GRADE. ALLOWABLE DEAD PLUS LIVE LOAD SOIL PRESSURE = 1500 PSF. 3.1 CONCRETE: ALL CONCRETE SHALL BE NORMAL WEIGHT OF 145 PCF USING HARDROCK AGGREGATES. MINIMUM 28-DAY COMPRESSIVE STRENGTH, fc, USED FOR DESIGN = 2500 PSI. 4.1 REINFORCING STEEL: REBAR SHALL CONFORM TO ASTM A615 OR ASTM A706 (A706 REQ'D. FOR ALL REINFORCING TO BE WELDED) AND SHALL BE GRADE 60 (fy = 60 KSI) DEFORMED BARS U.N.O. REINFORCING IN SLABS ON GRADE MAY BE GRADE 40 (fy = 40 KSI) DEFORMED BARS FOR ALL BARS #4 AND SMALLER U.N.O. ON PLANS OR DETAILS. 5.1 STRUCTURAL STEEL: STANDARD AND YIELD STRENGTH SHALL BE AS FOLLOWS U.N.O.: SHAPE: STANDARD: ROLLED WIDE FLANGE SECTIONS ASTM A992 OTHER STANDARD STEEL SHAPES AND ROLLED SECTIONS ASTM A36 BARS AND PLATES ASTM A36 PIPES ASTM A501 HOLLOW STRUCT. SECTIONS (RECT.) HOLLOW STRUCT. SECTIONS (ROUND) BOLTS (EXCEPT IN WOOD CONNECTIONS) NUTS WASHERS ANCHOR RODS OR ASTM A53 TYPE E OR S, GRADE B ASTM A500, GRADE C ASTM A500, GRADE C ASTM A325X ASTM A563 ASTM F436 ASTM F1554, GRADE 36 OR GRADE 55 WHERE NOTED (GRADE 55 RODS SHALL COMPLY WITH WELDABILITY SUPPLEMENT S1) Fy: 50 KSI 36 KSI 36 KSI 36 KSI 35 KSI 50 KSI 46 KSI 36 KSI 55 KSI WELDS E-70 SERIES --- THREADED ROD, EPDXY BOLTS, STUDS AND BOLTS IN WOOD CONNECTIONS ASTM A307 --- 6.1 SAWN LUMBER: SPECIES AND MINIMUM GRADE SHALL BE AS FOLLOWS U.N.O.: USE: SPECIES AND GRADE: 2X4 TOP PLATES DOUGLAS FIR STANDARD 2X4 STUDS (UP TO 10'-0"), BLOCKING DOUGLAS FIR STUD 2X4 STUDS (OVER 10'-0") DOUGLAS FIR No. 2 2X6 TOP PLATES DOUGLAS FIR No. 2 2X6 STUDS (OVER 10'-0") DOUGLAS FIR No. 2 2X6 STUDS (UP TO 10'-0"), BLOCKING DOUGLAS FIR STUD 6X BEAMS AND 6X POSTS DOUGLAS FIR No. 1 JOISTS, AND ALL OTHER SAWN LUMBER DOUGLAS FIR No. 2 6.2 GLB: GLULAM BEAMS (GLB) SHALL BE DOUGLAS FIR COMBINATION 24F-V4 U.N.O. 6.3 PLYWOOD: C-D OR C-C SHEATHING CONFORMING TO THE FOLLOWING NOMINAL THICKNESS, SPAN RATING AND NAILING PATTERN U.N.O. NAILING IS ON CENTER SPACING: THICKNESS: SPAN RATING: EDGE NAILING: FIELD NAILING: THICKNESS: SPAN RATING: EDGE NAILING: FIELD NAILING: 3/8" 24/0 8d AT 6" 8d AT 12" 3/4" 48/24 1 Od AT 6" 10d AT 12" 7/16" 24/16 8d AT 6" 8d AT 12" 1" 60/48 1 Od AT 6" 10d AT 12" 15/32" 32/16 8d AT 6" 8d AT 12" 1 1/8" 60/48 1 Od AT 6" 10d AT 12" 6.4 NAILS: ALL NAILS EXCEPT 16d NAILS SHALL BE COMMON NAILS U.N.O. 16d NAILS MAY BE 16d SINKER, 16d BOX OR 12d COMMON U.N.O. PROJECT: No: SHEET: RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGN DEAD LOADS SLOPED ROOF: ASPHALT SHINGLES 2.5 1/2" PLYWD 1.5 TRUSSES OR RAFTERS AT 24" O.C. 3.0 INSULATION 1.0 1/2" GYPBD CEILING 2.0 MECH & MISC 4.0 DL (PSF) : 14.0 FLOOR: FLOOR COVERING 1.5 3/4" PLYWD SHEATHING 2.5 TRUSSES OR JOISTS AT 24" O.C. 3.5 1/2" GYPBD CEILING 2.0 MECH & MISC 4.5 DL (PSF) : 14.0 EXTERIOR WALLS: 3/8" STUCCO 6.0 WALL SHEATHING 0.5 2x4 STUDS AT 16" O.C. 1.1 1/2" GYPBD 2.0 INSULATION 0.7 MISC. 1.7 DL (PSF) : 12.0 STONE VENEER ADD (PSF DL) : 6 INTERIOR WALLS: 1/2" GYPBD 2.0 2x4 STUDS AT 16" O.C. 1.1 1/2" GYPBD 2.0 MISC. 1.9 DL (PSF) : 7.0 230119 LOADS v20220922 RESIDENTIAL Copyright WRIGHT ENGINEERS RIGHT STRUCTURAL ENGINEERS UPDATE 02-12-03 PROJECT: No: SHEET: RES U B Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SNOW DRIFT LOADS AT LOWER ROOFS AND PROJECTIONS ASCE 7 SECTION 7.7, 7.8 y (pcf) : 16.6 hb (ft): 1.20 LENGTH OF LOWER LENGTH ROOF OR CONTROLLING DRIFT OF UPPER PROJECTION PEAK PRESSURE ROOF / PARAPET WINDWARD LEEWARD AND WIDTH h, (ft) I, (ft) I, (ft) hd (ft) Pd (psf) hd (ft) Pd (psf) Pd (psf) W (ft) DESIGN SNOW LOADS ASCE7-16 CHAPTER 7 RISK CAT: II I: 1 Ce : 1.0 Ct : 1.0 CS: 1.0 LOCATION hl (ft) RIGHT STRUCTURAL ENGINEERS P. (psf): 20 Pf (psf): 20 Ps (psf): 20 Suroharge Load Due to Drifting Balanced Snow Load FIGURE 7-8 CONFIGURATION OF SNOW DRIFTS ON LOWER ROOFS UNBALANCED SNOW LOAD WINDWARD LEEWARD (HIP & GABLE ROOFS) ASCE 7 SECTION 7.6.1 W (ft) (ft) Ps (psf) hd (ft) P. (psf) W (ft) ROOF PITCH= 0:12 0 0.00 0.00 0.00 0.00 0.00 SLIDING SNOW ASCE 7 SECTION 7.9 W (ft) Psllde (PS0 Wslide(ft) 10 5.33 15.00 PROJECT: No: SHEET: RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT RIGHT STRUCTURAL ENGINEERS I I I I 13'-2" J / / / 4'-0" 3'-10" 3'-4" 2'-0" / i 10" 2'-0" i / Z coEE J, - U _11 o � o co N ro > 13'-8 1 /21 E l< II Le � I u 1 j of II 1 _� --11----- -- - - --- ---- , F1 F1 c1 ;KITCHEN B1 a; Ir----------------------- --� I , EE 04 I I I �I I II II I 1 II I I ILI III II C� - EE LL 1H II w p i l l III II I II�II II w y, I Z -4- - -��-- DI 3X5SKYLIGHT -J JG l CENTERED ABOVE ISLAND N I I I I ; I 0 I I , J I I -------------------------------- --J 13'-2" KITCHEN FLOOR PLAN SCALE: 1/8"=1'-0" 08.29.22 e PROJECT: No: SHEET: RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BEAM: B1 REDUCED SPAN (FT) : 14.00 UL (PSF) LL (PSF) LL (PSF) I KItS (FT) WTL (PLF) WILL (PLF) UNBRACED L (FT): 14.00 ROOF 14 20 25 16 624 400 D OTL < L/ 240 FLOOR 14 40 40 10 540 400 S ALL < L/ 360 WALL 10 ---- ---- 10 100 ---- LL SNOW? [PSF] : 25 MISC 20 ---- ---- 1 20 ---- UP ROOF SLOPE: 2:12 UNIFORM LOAD (PLF) : 1284 800 DN ARTRIB (SO FT) : 0 TYPE AFTRIB (SO FT) : 140 AT X LOAD COMBINATION REACTIONS END REACTIONS BY CASE: INITIAL DIR. LEFT (K) RIGHT (K) MOMENT (K-FT) LEFT (LB) RIGHT (LB) D-1 3.39 3.39 11.86 D 3388 3388 CONTROLLING LC: LC - 4 1 LC - 4 1 LC - 8 DL ONLY D+L-2 6.19 6.19 21.66 S 2800 2800 OPTIONS N (PSI) fb (PSI) A (IN) I SPAN /A A (IN) % CAF D+(Lr or S)-3 6.19 6.19 21.66 LL 2800 2800 D+0.75(L+Lr or S) -4 7.59 7.59 26.56 (ASD) SEISMIC UP -308 -308 D+(0.6W or 0.7E)-5 3.70 3.70 12.94 (ASD) SEISMIC DN 308 308 3 1/8 x 21 GLB 130 1388 0.16 1055 0.10 97.4 D+0.75(L+(Lr/S)+(0.6W/0.7E))-6 7.82 7.82 27_37 (ASD) WIND UP 0 0 5 1/8 x 13 1/2 GLB 138 2047 0.37 460 0.22 93.5 0.6D+(0.7E or 0.6W)-7 1.72 1.72 7.11 (ASD) WIND DN 0 0 8 3/4 x 10 1/2 GLB 109 1982 0.46 369 0.28 99.2 (Deflection Only) L+Lr-8 5.60 5.60 19.60 RIGHT STRUCTURAL ENGINEERS POINT LOADS (LBS): 1 2 3 4 5 6 'ROJECT: No: SHEET: C1L C1R -11110. RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT CD: 1.00 WOOD POST AXIAL LOAD CAPACITY (KIPS) * ASSUMES POST IS BRACED IN WEAK DIRECTION DF SOLE PLATE MAX POST REACTION = 7.82K RIGHT STRUCTURAL ENGINEERS POST SOLE PLATE CRUSHING 6 7 7.71 8 POST HEIGHT (FT) 8.71 9 10 11 12 13 20 2 x 4 DF STUD * 3.28 3.40 2.89 2.54 2.41 2.12 2.01 1.68 1.42 1.22 1.05 --- 2 x 4 DF No.2 * 3.28 4.67 3.72 3.18 2.98 2.57 2.42 2.00 1.67 1.42 1.22 --- 4 x 4 DF No 2 7.66 10.89 8.68 7.41 6.96 6.00 5.66 4.67 3.90 3.31 2.84 --- 4 x 6 DF No 2 12.03 16.85 13.51 11.56 10.87 9.38 8.85 7.31 6.12 5.19 4.46 --- 4 x 8 DF No 2 15.86 21.84 17.62 15.12 14.22 12.29 11.60 9.60 8.04 6.83 5.86 --- 4 x 10 OF No 2 20.24 27.34 22.21 19.12 18.00 15.58 14.72 12.19 10.23 8.69 7.46 --- 4 x 12 OF No 2 24.61 33.26 27.01 23.25 21.89 18.95 17.90 14.83 12.44 10.57 9.08 --- 2 x 6 DF STUD * 5.16 6.41 6.14 5.91 5.80 5.51 5.39 4.93 4.45 3.99 3.56 1.71 2 x 6 DF No 2 * 5.16 10.49 9.66 8.98 8.68 7.95 7.65 6.67 5.79 5.04 4.40 1.99 6 x 6 DF No 1 18.91 27.56 26.34 25.28 24.80 23.51 22.96 20.92 18.83 16.82 14.98 7.13 6 x 8 DF No 1 25.78 37.59 35.92 34.47 33.81 32.07 31.30 28.52 25.68 22.94 20.43 9.73 6 x 10 OF No 1 32.66 44.42 42.66 41.12 40.43 38.56 37.73 34.69 31.48 28.32 25.36 12.25 6 x 12 OF No 1 39.53 53.77 51.64 49.78 48.94 46.67 45.68 41.99 38.11 34.28 30.70 14.83 8 x 8 DF No 1 35.16 53.81 52.79 51.91 51.52 50.44 49.96 48.09 45.89 43.41 40.69 23.01 CD : 1.15 POST SOLE PLATE CRUSHING 6 7 7.71 8 POST HEIGHT (FT) 8.71 9 10 11 12 13 20 2 x 4 DF STUD * 3.28 3.66 3.04 2.64 2.50 2.17 2.06 1.71 1.44 1.23 1.06 --- 2 x 4 DF No.2 * 3.28 4.86 3.82 3.24 3.04 2.61 2.45 2.02 1.69 1.43 1.22 --- 4 x 4 DF No 2 7.66 11.35 8.91 7.56 7.08 6.08 5.73 4.71 3.93 3.33 2.85 --- 4 x 6 DF No 2 12.03 17.62 13.90 11.81 11.07 9.52 8.97 7.38 6.17 5.22 4.48 --- 4 x 8 DF No 2 15.86 22.91 18.16 15.47 14.51 12.49 11.77 9.70 8.11 6.87 5.89 --- 4 x 10 DF No 2 20.24 28.78 22.95 19.59 18.40 15.85 14.95 12.33 10.32 8.75 7.51 --- 4 x 12 OF No 2 24.61 35.00 27.91 23.83 22.37 19.28 18.18 15.00 12.55 10.64 9.13 --- 2 x 6 DF STUD * 5.16 7.25 6.88 6.55 6.41 6.02 5.86 5.27 4.70 4.16 3.68 1.72 2 x 6 DF No 2 * 5.16 11.67 10.56 9.67 9.30 8.41 8.05 6.92 5.96 5.15 4.47 2.00 6 x 6 DF No 1 18.91 31.13 29.44 27.98 27.33 25.62 24.89 22.31 19.80 17.50 15.46 7.20 6 x 8 DF No 1 25.78 42.45 40.14 38.15 37.26 34.93 33.94 30.43 27.00 23.86 21.08 9.82 6 x 10 DF No 1 32.66 50.27 47.82 45.71 44.76 42.24 41.15 37.23 33.30 29.60 26.26 12.37 6 x 12 OF No 1 39.53 60.85 57.89 55.33 54.18 51.13 49.81 45.06 40.31 35.83 31.79 14.98 8 x 8 DF No 1 35.16 61.40 60.00 58.80 58.25 56.76 56.09 53.51 50.53 47.22 43.73 23.51 CID: 1.60 POST SOLE PLATE CRUSHING 6 7 7.71 8 POST HEIGHT (FT) 8.71 9 10 11 12 13 20 2 x 4 DF STUD * 3.28 4.16 3.30 2.81 2.64 2.27 2.14 1.76 1.48 1.25 1.07 --- 2 x 4 DF No.2 * 3.28 5.22 3.99 3.35 3.13 2.67 2.51 2.05 1.71 1.44 1.23 --- 4 x 4 DF No 2 7.66 12.18 9.32 7.82 7.30 6.23 5.85 4.79 3.99 3.37 2.88 --- 4 x 6 DF No 2 12.03 18.99 14.57 12.24 11.44 9.76 9.18 7.51 6.25 5.28 4.52 --- 4 x 8 DF No 2 15.86 24.83 19.11 16.07 15.02 12.83 12.07 9.88 8.23 6.96 5.95 --- 4 x 10 DF No 2 20.24 31.37 24.23 20.41 19.09 16.32 15.35 12.58 10.48 8.86 7.59 --- 4 x 12 OF No 2 24.61 38.16 29.47 24.82 23.21 19.85 18.67 15.30 12.75 10.78 9.23 --- 2 x 6 DF STUD * 5.16 9.52 8.73 8.08 7.80 7.11 6.84 5.93 5.14 4.46 3.89 1.75 2 x 6 DF No 2 * 5.16 14.56 12.48 11.05 10.49 9.24 8.78 7.37 6.24 5.34 4.61 2.02 6 x 6 DF No 1 18.91 40.75 37.18 34.29 33.07 30.07 28.87 24.97 21.57 18.69 16.28 7.31 6 x 8 DF No 1 25.78 55.57 50.70 46.76 45.10 41.00 39.37 34.05 29.41 25.48 22.20 9.97 6 x 10 DF No 1 32.66 66.24 61.04 56.75 54.90 50.28 48.40 42.20 36.65 31.87 27.83 12.59 6 x 12 OF No 1 39.53 80.18 73.89 68.69 66.45 60.87 58.59 51.08 44.36 38.58 33.69 15.24 8 x 8 DF No 1 35.16 83.32 80.33 77.73 76.55 73.37 71.95 66.67 60.97 55.22 49.72 24.38 PROJECT: No: SHEET: RESUB Mar 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Description: FF11 fc (psi): 2500 Conc. Wt. (pcf): 145 Fy (ksi): 60 Clr Cvr. Bot (in): 3 Allow. Soil Bearing (psf): 1500 Surcharge (psf): 0 Snow (Y/N): Y f1 (IBC 1605.2.1): 0.5 Light Wt. Conc. Ir : 1 LOADING DL (k): 3.40 LL (k): 2.80 RLL (k): 0.00 SL(k): 2.80 FOOTING GEOMETRY Min Dim. For Sq. Ftg. (ft): 2.37 Length X-Dir. (ft): 2.50 Width Y-Dir. (ft): 2.50 Thickness (in): 12.00 Min Ftg. Thickness (in): 5.49 Spread Footing Design (Design based on ACI 318-14) Column Type: Wood Column Column Length (in): 6 Column Width (in): 6 Flexure: 0.90 � Shear: 0.75 Bearing: 0.65 REINFORCING DEVELOPMENT Yc = 1.0 Ye= 1.0 Ys = 0.8 Id = 18.0 FOOTING REINFORCING X-Dir. Reinf.: (3) # 5 Y-Dir. Reinf.: (3) # 5 SOIL BEARING Max Load Combination Bearing (psf) Max/Allow. 1DL 689 0.46 1DL+1LL 1137 0.76 1DL+1SL 1137 0.76 1DL+0.75LL+0.75SL 1361 0.91 FOOTING FLEXURE DESIGN Critical Section from Column Center X - Dir. (in): 3 Critical Section from Column Center Y - Dir. (in): 3 pT&S: 0.0018 pmax: 0.0134 01: 0.85 d (in): 8.38 I �w I `3 I � I � � I 3 I I Q I y I I COLIIM"ASE PLATE LENGTH I I -------------� FOOTING LENGTH j RIGHT STRUCTURAL ENGINEERS X-Dir. X-Dir. Y-Dir. Y-Dir. As Req'd - As Req'd - X-Dir. As As Req'd - As Req'd - Y-Dir. As Ultimate Mu - YY Strength T & S Provided Mu - XX Strength T & S Provided Load Combination Bearing (psf) (k-ft) (in^2) (in^2) (in^2) (k-ft) (in^2) (in^2) (in^2) 1ADL 761.60 0.95 0.03 0.65 0.92 0.95 0.03 0.65 0.92 1.2DL+1.6LL+0.5SL 1593.60 1.99 0.05 0.65 0.92 1.99 0.05 0.65 0.92 1.2DL+0.5LL+1.6SL 1593.60 1.99 0.05 0.65 0.92 1.99 0.05 0.65 0.92 FOOTING SHEAR CHECK Column as : 40 D:1 Two Way (Punching) �Vc (k): 72.2 One Way (X-Dir. Cut) �Vc (k): 18.8 Critical Section from Column Center X - Dir. (in): 11.375 One Way (Y-Dir. Cut) OVc (k): 18.8 Critical Section from Column Center Y - Dir. (in): 11.375 Punching X-Dir. Cut Y-Dir. Cut Load Combination Vu (k) Vu/�Vc Vu (k) Vu/�Vc Vu (k) Vu/�Vc 1ADL 3.67 0.051 0.58 0.031 0.58 0.031 1.2DL+1.6LL+0.5SL 7.67 0.106 1.20 0.064 1.20 0.064 1.2DL+0.5LL+1.6SL 7.67 0.106 1.20 0.064 1.20 0.064 CONCRETE BEARING CHECK Az/Al: 2.00 Bearing Capacity �Bn (k): 99.5 Load Combination Bu (k) Bu/�Bn 1ADL 4.76 0.048 1.2DL+1.6LL+0.5SL 9.96 0.100 1.2DL+0.5LL+1.6SL 9.96 0.100 230119 FOOTINGS 20220211Spread Ftg Copyright Wright Engineers Update 08-27-19 PROJECT: No: SHEET: