Loading...
APPROVED PLN BLD-RESUB 1 BLD2022-1742+Architectural_Plan+3.7.2023_11.35.09_PM+3407889TSEHAY RES. INTERIOR ALTERATION FOR AFH CONVERSION v, ifA I D NOTES GENERAL NOTES SYMBOL NOTATION PROJECT NOTE: OWNER: 2018 IRC R310.1 Emergency Escape and Rescue 1. THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT TESEHAY GHEBRESILASSIE Opening Required DOCUMENTS. � we nfa+ru�r. 8907 192ND ST SW, EDMONDS, WA 98026 Basements, habitable attics and every sleeping room 2. THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT, ra. ':1iaROw (t .HMw,�) - - shall have not less than one operable emergency THE CONDITIONS OF CONTRACT GENERAL, SUPPLEMENTARY, AND OTHER w4an�c ARCH. DESIGNER: p g y ( SATTNSi1tAT1gl9 eMD DESIGN PRACTICE escape and rescue opening. CONDITIONS), THE DRAWINGS, THE SPECIFICATIONS, AND ALL ADDENDA ISSUED PRIOR oaoQEllrr ANT�AIU1aEM9tP1 04151 TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. FF_ `°CEUM `° B�` ermias@eMDdesignpractice.com 2018 IRC R310.2.1 Minimum Opening Area 3. eMD IS THE AUTHOR OF THESE PLANS AND CLAIMS A COPYRIGHT IN THESE PLANS • ¢ ru'CMUBLOU Emergency and escape rescue openings shall have a AND THE DESIGNS CONTAINED IN THESE PLANS. THIS CLAIM IS MADE UNDER TITLE 17 �E�+ FIRAT _ � RDOr5M)PE STRUCT. ENGINEER T net clear opening of not less than 5.7 square feet. OF THE UNITED STATES CODE AND ALL APPLICABLE TREATIES AND FOREIGN LAWS. HDOFU PEPLM �--- Eor r> AM ENGINEERING The net clear opening dimensions required b this THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY. eMD asrade@amengineering.works p g q Y a� s�T>ox is =1a : UODp sm3t ELFs _ - section shall be obtained by the normal operation of WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY M 4* the emergency escape and rescue opening from the ANOTHER PARTY AND NO LICENSE IS GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO Y4UY? RIVIM inside. The net clear height opening shall be not less ANOTHER PARTY. '� PROPERTY INFO than 24 inches and the net clear width shall be not 4. THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY THE „ WALL`"0"`T`� ac YWWAX �_ 1_ °6"1'a less than 20 inches. CONTRACT DOCUMENTS AND INCLUDES ALL LABOR NECESSARY TO PRODUCE SUCH WopMM Cif lJ 9 iFi? ADDRESS: 8907 192ND ST SW, Exception: Grade floor or below grade openings shall CONSTRUCTION, AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE UEFAKCALLOUT COKMURDINr EDMONDS, WA, 98026 ha net cle ening of less 5 squ eet INCORPORATED IN SUCH CONSTRUCTION. ti 7) �rwSWSHE►NNC, 5. SHOP DRAWINGS, PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE UJNT9lA ME APN: 00434600002811 -�� CONTRACT DOCUMENTS. THE DESIGNER WILL REVIEW THEM, BUT ONLY FOR °glur"ur+ LOT: N/A LL _ I A� F:fVATtaFi91J81}SE 2018 IRC R310.2.2 Window Sill Height CONFORMANCE WITH THE DESIGN CONCEPT OF THE WORK AND WITH THE AufOEr11ex + MATCH LW ZONE: RS-12 Where a window is provided as the emergency INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT �+` e escape and rescue opening, it shall have a sill height BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM THE REQUIREMENTS OF NAME -- arrrrrAR& AIG+ l%UL+1TkM of not more than 44 inches above the floor; where the THE CONTRACT DOCUMENTS BY THE DESIGNER REVIEW OF SHOP DRAWINGS, b MMSER-_ -. so.Em: MO uv sill height is below grade, it shall be provided with a PRODUCT DATA OR SAMPLES. aHD u� PL r SHEET INDEX t .1 window well in accordance with Section R310.2.3. 6. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT w1 a+ - - - �5„� s�Ea 0 DOCUMENTS AND SHALL AT ONCE REPORT TO THE DESIGNER ANY ERROR, (V I! 8 IRC ion R3 dult Fa Homes 1 INCONSISTENCY OR OMISSIONS HE MAY DISCOVER. THE CONTRACTOR SHALL 1; rT y,°�p �LOq� -� -t - {'� °�'� ARCHITECTRURAL STRUCTRUAL 0 2018 IRC R330.6 Escape Windows and Doors PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS -x -x - EWE UK TECTW co Every sleeping room shall be provided with OR, WHERE REQUIRED, APPROVED SHOP DRAWINGS, PRODUCT DATA OR SAMPLES A0.1 TITLE SHEET S1.1 WOOD DETAILS Z emergency escape and rescue windows as required FOR SUCH PORTION OF THE WORK. 5+ul MSEWR T w a°aril r A1.0 SITE PLAN S1.2 WOOD DETAILS O by Section R310. No alternatives to the sill height 7. ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS. DRAWINGS ARE NOT A2.1 DEMO PLAN S2.1 FOUND. PLAN _ such as steps, raised platforms or other devices TO BE SCALED FOR INFORMATION IF UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF r.+r►k+FS -n'�v - r[vi�ne A2.2 FLOOR PLAN Q p p �,r,�� S2.2 UPPER FRAMING placed by the openings will be approved as meeting this WORK, CONSULT WITH THE DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. _ w,ATSIM F1 A3.1 ELEVATION S2.3 ROOF FRAMING requirement. 8. IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN -'- A9.1 DETAIL Q ON THE CONTRACT DOCUMENTS, THEN THEIR CONSTRUCTION SHALL BE OF THE SAME Note: CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR AND CODES 0. C� All grabbars should be installed on H. SHALL BE REVIEWED BY THE DESIGNER. blocking w/ capable of risisting a 2501b 9. ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM load R301.5 STANDARDS OF THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE AND BASED ON THE 2018 I.R.C, 2018 UPC, 2018 WA 0 I ALL APPLICABLE NATIONAL, STATE, AND LOCAL LAWS, REGULATIONS AND ORDINANCES. '- - E R D C -' -' TE - -' STATE ENERGY CODE, AND 2018 WA STATE NOTE: 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING I DRYER DUCTS AND EXTERIOR I Q Z ' 907.2.10.5 Interconnection CONSTRUCTION, AND ALL WORK SHALL CONFORM TO PERTINENT SAFETY � VENT CAPS ARE NOT PERMITTED AMENDMENTS 0 Where more than one smoke alarm is required to be installed REGULATIONS. I TO BE INSTALLED IN THE I OCCUPANCY GROUP R C within an idividual dwelling unit or sleeping unit 11. THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL, DWELLING G in Group r or 1-1 occupancies, the smoke alarms shall be TELEPHONE, ELECTRICAL, LIGHTING AND PLUMBING INCLUDING ALL PIPING, DUCT _ _ _ _ _ _ J CONSTRUCTION TYPE VB 0 Q interconnected in such a manner that the activation WORK AND CONDUIT. COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION T of one alarm will activete all of the alarms in the individual AND MAINTENANCE OF THE ABOVE EQUIPMENT. FLOOR AREA (SF) LIVING GARAGE W unit. Physical interconnection of smoke alarms shall 12. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST not be required where listed wireless alarms are installed and SKILL AND ATTENTION, HE/SHE SHALL BE SOLELY RESPONSIBLE FOR ALL I EXISTING UPPER LEVEL 2,208SF W all alarms sound upon activation of one alarm. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND EXISTING BASEMENT LEVEL 1,716SF The alarm shall be clearly audible in the all bedrooms over FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. EXISTING ATTCHED GARAGE 780SF background noise levels with all interventing door 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF (142SF) Z closed. HIS/HER EMPLOYEES, SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES, AND GARAGE CONV. 142SF I - OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACT WITH THE CONTRACTOR. ` TOTAL LIVING AREA 4,066SF 638SF ^ V ) 14. THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER V J TO INSURE TIMELY COMPLETION OF THE PROJECT. VICINITY MAP REQUIRED SEPARATION NO W Q - 15. THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM 7 ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS/HER OPERATIONS. ` #OF STORIES 2 L AT THE COMPLETION OF THE WORK, HE/SHE SHALL REMOVE ALL HIS/HER WASTE ` �- MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HIS/HER Sea lL �.rk `� FULL INKL r N '- TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY, AND SURPLUS MATERIALS. H..unPark �� Q 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR r PROTECTION OF ALL EXISTING AND PROPOSED PIPING, UTILITIES, STRUCTURES, I'EI AI VILE ` lath 5iSW ENERGY NOTES = - - -� - ADJACENT STREETS, AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION. LYnp�dale.Pac 17. UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR E907 n Edmonds, St 80SVVPitnk. SheJtes Costc° S" I Edmonds, � g8t326 ` ENERGY CODE COMPLIANCE SHALL BE AS PER ��^ O SHALL PROVIDE AND PAY FOR ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, THE WASHINGTON STATE ENERGYCODE 2018. V ) CONSTRUCTION EQUIPMENT, MACHINERY, WATER, HEAT, UTILITIES, TRANSPORTATION, ` MINIMUM INSULATION (R) VALUES OR U-VALUES AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND m OF COMPONENTS SHALL BE AS FOLLOWS: co COMPLETION OF THE WORK. 18. WHERE CONFLICTS OCCUR, COORDINATE THE LAYOUT AND EXACT LOCATION OF ` 28 MIN. 0. t ALL PARTITIONS, DOORS, TELEPHONES AND ELECTRICAL/COMMUNICATION OUTLETS * 524 GLAZING, VERTICAL (U-VALUE) by DOOR, ENTRANCE (U-VALUE)0. MIN. - _ AND SWITCHES WITH DESIGNER IN THE FIELD BEFORE PROCEEDING WITH CEILING INSULATION (ATTIC) R-49 MIN. I CONSTRUCTION. CEILING INSULATION (VAULTED) R-38 MIN. 1 �li 11 19. WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT INSULATED WALLS R-21 MIN. 4 Lynfw. r = WILL MATERIALLY AFFECT THE QUALITY OR EXTENT OF THE WORK, SUCH CONFLICT SLAB EDGE AL SLEEPER: R-7.5 SHALL BE RESOLVED TO THE SATISFACTION OF THE DESIGNER BEFORE THE AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED, FABRICATED AND/OR INSTALLED. PROJECT LOCATION FLOOR R-38 MIN. 20. WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE -' TO BE INSTALLED -THE CONTRACTOR SHALL VERIFY ROUGH OR FINISHED DIMENSIONS ENERGY CREDIT NOTES (1.5 CREDITS NEEDED): IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. ` 1.OPTION 3.1 (CREDIT 1.0) HIGH EFFICIENCY HVAC co 21. THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE EQUIPMENT: ENERGY STAR RATED GAS OR N I cn FROM DEFECTS FOR A MINIMUM OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND F F z0 co PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED BY THE ,„-............-LE.HFICH T _ 2.OPTION 7.1(CREDIT 0.5) APPLIANCE PACKAGE: c) o DEFECTS OR REPAIR THEREOF, AT NO EXPENSE TO THE OWNER. GUARANTEE ALL FO THE FOLLOWING APPLIANCES SHALL BE > PERIODS OF GREATER THAN ONE YEAR MAY BE REQUIRED AND CONTAINED WITHIN NEW AND INSTALLED IN THE DWELLING UNIT AN Lu a THE CONTRACT DOCUMENTS. Edmonds-Woodway SHALL MEET THE FOLLOWING STANDARDS: F_ 22. UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR High School 212eh � SW DISHWASHER,REFRIGERATOR, WASHING w CityOf Edmonds I SHALL SECURE AND PAY FOR THE BUILDING PERMIT AND FOR ALL OTHER PERMITS AND CarMax• MACHINE (ENERGY STAR) VENTLESS DRYER W/ _ Building Department GOVERNMENTAL FEES, LICENSES AND INSPECTIONS NECESSARY FOR THE PROPER 8°+4 r�r� MINI. CEF RATING OF 5.2 (ENERGY STAR) Work REMODEL-AFH EXECUTION AND COMPLETION OF THE WORK. R SediSi` 23. WHERE ANY ITEM AND/OR MATERIAL IS INDICATED IN THE CONTRACT DOCUMENTS, Address 8so�1g2NDSTsw - AND NOT NECESSARILY DETAILED IN EACH SPECIFIC CASE, BUT IS REQUIRED FOR A ` Emi*d.Cams PROJECT DESCRIPTION Owner TSEHAYGHEBRESILAssIE COMPLETE AND PROFESSIONAL INSTALLATION SUCH ITEM AND/OR MATERIAL SHALL BE WmCD Foods Approved Date 4/6/2023 PROVIDED AS IF SHOWN AND DETAILED IN FULL. PROVIDE MEANS TO FURNISH AND , .+' RESU B v 0o oo INSTALL. Interior work (Lower level only includes): To modify and remodel the Building Official /I etH!( BG00lH�ZGci Mih $z Dt existing house (lower level) to convert it for the purpose used for AFH. Mar 08 2023 The work will consist of modification and remodeling of all the existing Permit Number) BLD2023-0245 bedrooms and bathrooms, To add a new bathroom, modifying the 1 CITY OF EDMONDS existing bar sink area by expanding the space. DEVELOPMENT SERVICES M I v, DEPARTMENT r Interior work (Upper level only includes): To remove walls in the living i 94 Ranch Iar4e room, kitchen, and dining area (if possible, per structural engineer). To ALL WORK SUBJECT relocate the existing kitchen area, close off the existing stair access, and OBTAIN ELECTRICAL APPROVED �:' relocate. To modify and remodel existing bathrooms and add a new PERMIT FROM TO FIELD Q fBRC If laundry closet /1/2 bath, lastly expand the existing master bathroom and PLANS MUST BE IQTE i I- closet. STATE LABOR & INSPECTION FOR ,=Ktr, SWINDUSTRIES CODE COMPLIANCE ON JOB SITE new backyard )patio.remove the existing stair for the front upper entry& Lu F_ ■ U WHERE ADDITIONS OR ALTERATIONS REQUIRE A r , AEARMANDCODETEDC ORS INTERCONNECTED II SEPARATE PLUMBING PERMIT C) CL DWELLING ARE REQUIRED. REFER T02018IRC REQUIRED FOR THIS PROJECT. Z z I L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ (D 0 R314 AND R315 FOR MORE INFORMATION. B L D2022-1742 ALL MACHANICAL FIXTURE ENT, o w o 0 I- o 19'-8" 2 UF'F'tF� LEVEL. 1/4" = 1'-0" (E) F (E) WIND, (E) WALL 3 Section 1 1/2111-011 WALL LEGEND EXISTING TO REMAIN NEW EXTERIOR STUD WALL- 2X6 @16"OC W/ SIDINGO/ HOUSE WRAP O/PLYW'D ON EXT. FACE, 1/2" GYP. BD. O/VAPOR BARRIER AT INSIDE FACE AND R-21 BATTS BTWN, U.N.O NEW 4" INTERIOR STUD WALL - 2X4 @ 16"OC W/ 1/2" GYP. BD. EA. SIDE AND SOUND BATT INSUL. BTWN.USE 2X6 WHERE NEC. FOR PLUMBING U.N.O. EXIST 6" STUDWALL W/ R-21 INSU FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE FROM FACE -OF -STUD TO FACE -OF - STUD, AND FACE -OF -BLOCK TO FACE -OF -BLOCK. 21UMBER TO BE FOREST STEWARDSHIP COUNCIL CERTIFIED DOUGLAS FIR#2 OR BETTER. &FINISH MATERIALS NOT SPECIFIED TO BE COORDINATED WITH OWNER. 4. PROVIDE SOLID BLOCKING BEHIND ALL FIXTURES AND WALL MOUNTED ACCESSORIES. 5. PROVIDE WALL & FLOOR STOPS AT DOORS AS REQUIRED. 6.INTERIOR DOOR HARDWARE TO BE LEVER TYPE AND OPERABLE WITH ONE HAND. FORCE REQUIRED TO ACTIVATE DOOR AND HARDWARE SHALL BE 5.0 LBS. MAX. REQUIRED EXIT DOOR HARDWARE SHALL UNLOCK INSIDE AND OUTSIDE MECHANISMS WHEN EXITING THE BUILDING ALLOWING REENTRY INTO THE AFH WITHOUT THE USE OF A KEY, TOOL OR SPECIAL KNOWLEDGE. 7. ALL SLEEPING ROOM WINDOWS SHALL BE AS PER IRC REQ. (N)PATIO 196SF PER STRUCT. (N) 3'0" X6'0" FI) (N) 5'0"X6'8" FR W/ TEMP GL SAFTY, GLASS NOTE: 2018 IRC R310.2.2 Window Sill Height Where a window is provided as the emergency escape and rescue opening, it shall have a sill heigl of not more than 44" inches above the floor; where sill height is below grade, it shall be provided with a window,well in accordance with Section R310.2.3 (E) FMAILY ROOM (N) POST PER STRUCT. (E) I I I I APPROVED FIVE POUND 2A:10B-C RATED FIRE EXTINGUISHER ON EACH FLOOR OF THE HOME (WAC 388-76-10810) (E) BEDROOM D 95.00S F NS1 (N) BEDROOM E _j 118.10SF 0 � NS1 Wil _ oc Iow z (N)3'0"X6'8" 2'-8" 6'-6" 00 _ J I (N) BEDROOM F (N)3'o°x6's° (o w POCKET o 107.89SF 00 2' - 4" ;0 w NS1 w (N) EQUIP. ER LEVEL. _ STORAGE 9' _ 00 o" X APPROVED FIVE POUND 2A:10B-C RATED FIRE EXTINGUISHER ON EACH ? FLOOR OF THE HOME (WAC 388-76-10810) (E) OC) E ER LE L. 0'-0" JC. SLAB 1ND PARKING (N)3'0"X6'8" 00 2'-4 X i b Z 2'-4" 00 (N)3'0"X6'8" rn u (E)5'0"X6'8" SL EGRESS SAFTY GLASS PE ACC. R308.42 (E) BEDROOM A 95.49S F NS1 4'-4" (N)3'0"X6'8" (N)3'0"X6'8" (E) BEDROOM B � u g 82.42SF 3 :X,. M A2.2 NS1 w OO CAREGIVER w 00 X o , z � (E) BEDROOM C BNSSF - v) Xwrn 00 00 O � in W W XY W o 0 [:�C-) z CL (N)3'0"X6'8" 0 (N)/ H �50CMF f 2'-7" ( BATH 5'-4" (N)3'0"X6'8" 2 9" (E) POST & BEAM TO REMAIN /EATING AREA 2'- 5'-3" U z U W w 2'-9" 2'-4" 5'-3" VERIFY 1/2" MAX ELEV. C/H @ OPENING OR ADD TRANSITION COVER. FINISH OPEN 3'WIDE MIN (N) ENTRY (E) POST STA. (N) BAR SINK REMIAN W/D ° (FOR PREP. AREA ONLY) 0 u (N) 50"X68" FR W/ TEMP GL (E) GARAGE X - o z EXIST. WALL INSTALL ADD 1 HR WALL z � _ R-21 INSUL AS NEEDED ASSEMBLY. 2X4 WOOD N (VERFY)'- STUDS @ 16" OC. 1 HR 10' - 4" FIRE RATED WALL Of DETAL (SEE 7/A9.1) 13 ' A9.1 (E)WALKWAY,,, (E) (E) LOWER LEVEL. 1/4" = 1,_0„ 24" W. HORIZ. GRAB BAR TO BE INSTALLED AT CONTROL END AND HEAD END WALL OF SHOWER W/IN 6"OF FACE. BOT @ +33"-36" 24" W. HORIZ. GRAB BAR TO BE INSTALLED AT BACK WALL OF SHOWER @ +33"-36" 36" W. HORIZ. GRAB BAR TO BE INSTALLED AT BACK WALL OF SHOWER @ +33"-36" 18" H. VERT. GRAB BAR TO BE INSTALLED AT CONTROL END AND HEAD WALL OF SHOWER W/IN 4" OF FACE. BOT @ +36"-42" AFF FOLDING DOWN GRAB BAR TO BE INSTALLED ON BOTH SIDE OF W/C @+33+36" CENTERALINE EXTENDING 28" FROM WALL, TYP.DISTANCE BETWEEN GRAB BARSSHALL BE BETWEEN 25" MIN. + 30" MAX PERMFD. METAL IRC COMPLIANT STAIR; STAIR MANUFACTURER TO PROVIDE SHOP DRAWINGS It is apparent a spiral staircase is being installed. All welding on site or in a facility shall be done by a WABO certified welder or WABO certified facility. i LL Q 0 LL z 0 I— Uj I- 0 LLJ z U) Uj Q �Uj U) L7 LU W a F_ w w 2 U) RESUB Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N MAX ELEV. MAX RIDGE= 119 25' - 00"" WEST ELEVATION 1/4" = 1'-0" (N) HANDRAII MAX ELEV. I� 25' - 0" NORTH ELEVATION 1/4" = 1'-0" J(E IN -FILL WALI TO MATCHE EXIST. FINIS PAIN i„„ 25' - 0" OOF TOP IL 22' - 55" 'OT PLAT I� 17' - 0'f R LEVEL. t 9'-0" - LOWER LEVE.L. 0'-0" MN EAST ELEVATION 1/4" = 1'-0" (E) ROOF ROOF TOP OIL 22' - 5" POT PLA IT 17'-0" 'PER LEVEL. AU 9'-0" LOWER LE � 0'-0" � PER EMAIL USE THIS PAGE - REMOVED OLD SHEET AND SLIP SHEETED THIS ONE IN O c0 L.L N z � 00 O 0') I- Q Q Lu cn o z Q O 0C 5 O o Lu Lu 3: I" z U) Cfi U) Lu Q z N Q � T Lu p U) 0') 1­ 00 Luw z O >a a U_ w w co U Q LD2022-174 r z (D Co U) Luw U U Q 0 z RESUB z w Mar 08 2023 w A Q w QDEPARTMENT CITY OF EDMONDS DEVELOPMENT SERVICES Q N Q N DUAL GLAZED VINYL SOLID WALL SHEATHING DBL. 2x FRAMING @ WINDOW WINDOW SYSTEM (SEE JAMB. SIDING TO MATCH EXIST. CORNERBEAD STRUCT.) CORNER BEAD 1/2" GYP. BD. SHIM AS REQ'D. NEW OR EXIST. SHIM AS REQ'D. WINDOW SOLID WALL TJI'S OR 2X HEADERt SHEATHING JOIST OR SEALANT W/ SILL (SEE (SEE STRUCT.) STRUCT.) RAFTER, TYP. BACKER ROD BELOW 2x4 FLAT @ 4' -0" 2x4 STUD WALL @ 16" O.C. 2x DF STUD BUTYL RUBBER FLASHING O.0 DBL. 2x FRAMING WALL W/ BATT 1/2" GYP. BD. W/ SELF -ADHESIVE GYPSUM BOARD @ WINDOW JAMB. INSULATION. BACKING. APPLY OVER INFILTRATION BARRIER NAILING AS REQUIRED BUTYL RUBBER FLASHING W/ SELF - R=10 RIGID A AS SHOWN. INSUL. 2x4 BOTTOM PLATE ADHESIVE BACKING. APPLY OVER SEALANT AS REQ'D. INFILTRATION BARRIER AS SHOWN. 26 GA. GALV. 5/8" TYPE "X" GYP. 0 HEAD BD. CEIL., TYP. 1/2" GYP. BD. FLASHING SOLID WALL SHEATHING (SEE 101 SIDING TO MATCH EXIST. CORNER SHIM AS NECESSARY BEAD DUAL GLAZED SEE PLAN FOR WALL TYPE 3/4" SUB FLOOR �►: STRUCT.) VINYL '' -- 2x DF STUD WALL W/ BUTYL RUBBER DUAL GLAZED W NDOW SYSTEM BATT INSULATION. FLASHING VINYL ------------------- MATCH SIDING TO EXIST. W/ SELF -ADHESIVE WINDOW SYSTEM BACKING. APPLY OVER INFILTRATION BARRIER SEALANT W/ BACKER AS SHOWN. ROD WALL AT FLOOR I D WINDOW SILL 1 3" = V-0" 2 WINDOW JAMB qy 3" = V-0" WINDOW HEAD 3 3" = V-0" 4 WALL TO PRARALLE 1"= V-0" 11 11/2"=1'-0"LVA A SOUND BATT INSUL. WHERE OCCURS 2X4 WOOD STUD WOOD STUDS WALL @16"O.0 PER WALL LEGEND 1 1/1 DIA 1/2" GYP. BD. TOP PLATES STAINLESS STEEL GRAB BAR I 1 1 /4" MAX DIA STAINLESS STEEL GRAB EA. PROVIDED 2X BLOCKINGI INWALLATPROVIDED BAR 2X SIDE CONTACT PAOINTS BLOCKING INW L AT CONTACT PAOINTS BASE EA. SIDE, TYP. z STUD u PRIES. �ET�60 PFERCENT TREATED2X OF STUD DEPTH 0'-6" a o'-6^ 0'-6" X 0'-6" PLATE 2"X4" WOOD STUDS 16" ON CENTER WITH 5/8" TYP X GYP SUM A WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED s fg IN. MIN,TQ EDQE O MAX. o - MAX. o m .145" DIA. POWDER WITH 6d COOLER OR WALLBOARD NAILS AT 7" ON CENTER WITH IN. MIN. TO EDGE z O n DRIVEN PINS @ 18" END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACHSIDE. 210 ? z O.C. ^^ m IBC TABLE 721.1(2) ITEM NUMBER 14-1.3 M CONC. SLAB, TYP. GRAB BARS AT SHOWER LOCATIONS U- 1 H R —TYP NOTCH MUST NOT DCE 49 PERCENT 4F STUD DEPTH C`I 7 .WALL WALL —SLAB DET. HOLES SHALL NOT BE IN 1 O LOCATED IN THE SAME GROSS SECTION OF CUT OFt NaT�CH IN STUD O O co 3" = 1'-0" ILL m z 1 1/2" BETWEEN 1 1/4" MAX DIA Q GRAB AND WALL 2. STAINLESS STEEL GRAB O STEP 1 - WCORNER STEP 2 - SAF TABS STEP 3 - SAF SILL STEP 4 - SAF JAMB STEP 5 - WINDOW TYP. INTERIOR WALL FRAMING 25"MIN.30"MAX. 30" 2' - 4" BAR PROVIINGPIN ALA BLOCKING IN WAL AT SAF SILL FLASHING 12 1'-3" 28" MAX. CONTACTPAOINTS < � /1 V � GRACE "VYCORNER" SELF ADHESIVE L 1s" MAX. Q OR SIMILIAR FLASHING (SAF) Lu z J Q LEAVE 4" OF PAPER W ON BOTTOM OF SILL FLASHING (TO BE GRAB BARS AT TOILETS )„ ADHERED TO BUILDILNG WRAP) w z \ w z Q � = I� ADD 1HR WALL 0 tW Ln ASSEMBLY. 2X4 WOOD 3/4 PLYWOOD m STEP 6 - SECOND SAF JAMB STEP 7 - METAL HEAD FLASHING STEP 8 - BUILDING WRAP STEP 9 - SAF HEAD FLASHING STUDS @ 16" OC. 1 HR SUBFLOOR FIRE RATED WALL DETAL (SEE 7/A9.1) R -7.5 RIGID INSUL. LEAVE 4" OF PAPER ON SIDE METAL HEAD FLASHING BETWEEN THE OF JAMB FLASHING (TO BE ADHERED TO BUILDING WRAP) SLEEPERS (E) CONC. SLAB ° \ - LOWER LEVEL. u o 2X4 PT. SLEEPLER�n_ @24" O.0 MAX. 01 _ oii F.- Lu V _ <It= ui 6 MIL VAPOR BARRIER N . REQUIRED ON TOP OF SLAB. m LAP SPLICES 12" MIN AND RUN z 6" MIN UP THE SIDES. V RESUB \ \ W Mar 08 2023Lu \ \ \ \ Q CITY OF DEVELOPME_�ES vQ \ ADHERE SILL &JAMB \ \ 13 S U B F LOO R ON S L E E P E RS DEPARTMENT • < z LAP ONTO SIDE FLASHING TO BUILDING WRAP \ \ Q Lu w OF WINDOW C L ^c1 W w � w NOTE: HOSE TEST FIRST WINDOW INSTALLED TO TEST FOR WATER INFILTRATION v o TYPICAL WINDOW FLASHING 8 3" = 1'-0" STRUCTURAL NOTES DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE (IBC). CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURAL COMPONENTS OF THE NEW AND EXISTING STRUCTURE UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. (E) FLOOR PLYWOOD (N) SIMP LUS HANGER (E) BEAM TO REMAIN, - CONTRACTOR TO VFY (N) ECCQ CAP r (N) POST PER PLAN (N) SIMP ABU46 BASE W/ 58" 0 EXP ANCHOR (4" EMBED) (E) FOOTING----,, #4x1'-4" @ 48" oc EACH SIDE STAGGERED SET IN EPDXY (4" EMBED) INTO (E) SLAB— ON—GRADE/(E)FTG so. (E) SLAB —ON —GRADE ROOF SNOW 25 PSF ROOF DL 12 PSF (N) GL HEADER BEAM PER PLAN =III=III=III=11I I11=III=III=III= (E) FLOOR BEAM (N) 2x FLOOR JOISTS (N) SIMP LCE4 CAP OR SIMILAR=1 I1=1I1=1 I1=-1I1=1I 1=1I1=1 i' FLOOR ILL 40 PSF @STAIR INFILL (N) POST PER PLAN SAWCUT (E) SLAB, TYP. FLOOR DL 15 PSF (E) 2x FLOOR JOISTS U (N) HEADER BEAM III=1 I=1 I=1 11= PER PLAN -III—III=III=1i' (N) FOOTING & REINFORCING DECK LL 60 PSF PER PLAN PER PLAN DECK DL 12 PSF SOIL BEARING 1500 PSF (ASSUMED) CARPENTRY POST - 6X, 8X DOUG-FIR #1, Fb =1200 PSI FRAMING - 2X, 4X HEM -FIR #2, Fb = 850 PSI GLU-LAM 24F-V4 LSL Fb = 2325 PSI, E = 1.55E6 FRAMING HARDWARE DESIGNATIONS ARE SIMPSON STRONG -TIE. USE FULL AMOUNT OF FASTENERS SPECIFIED BY MFR. HARDWARE IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE Z-MAX OR HOT -DIPPED GALVANIZED. FRAMING NAILING SHALL CONFORM TO TABLE 2304.10.1 OF THE 2018 IBC LINO. HEADERS SHALL BEAR ON (2) 2X TRIM STUDS. WALL: 15/32" THICK PLYWOOD OR OSB, 32/16, OR 1/2" THICK, 24/0. SHEATHING MAY BE LAID UP HORIZONTALLY OR VERTICALLY, UNSUPPORTED EDGES SHALL BE BLOCKED AND ALL EDGES SHALL BE NAILED WITH 8d @ 6"oc, NAIL WITH 8d @ 12"oc AT INTERMEDIATE SUPPORTS. NAIL SHEAR WALL SHEATHING TO ALL HOLDOWN STUDS USING EDGE NAIL SPACING WHEN HOLDOWN STUD DOES NOT OCCUR AT PANEL EDGES. FLOOR SHEATHING: 3/4" PLYWOOD OR OSB, T&G, 48/24 EXT GRADE NAIL FLOOR SHEATHING WITH 8d COMMON (.131 x 2-1/2" DIA) @ 6" O.C. AT PANEL EDGES AND 10" O.C. AT INTERMEDIATE SUPPORTS. CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS = 2500 PSI. PROVIDE A MINIMUM OF 51/2 SACKS CEMENT PER CUBIC YARD. CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60. MINIMUM CONCRETE COVER: CONCRETE CAST AGAINST EARTH - 3" CONCRETE EXPOSED TO EARTH OR WEATHER-1-1/2" REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 318 (LATEST EDITION). LAP ALL CONTINUOUS REINFORCEMENT 32". PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. ALL HOOKS SHALL BE "STANDARD" IN ACCORDANCE WITH ACI 318. FOUNDATIONS SHALL BEAR ON FIRM NATIVE SOILS OR COMPACTED STRUCTURAL FILL. CLEAN EXCAVATIONS OF LOOSE SOIL PRIOR TO PLACING CONCRETE. (N) FLOOR INFILL DETAIL 1"=1'-0"� 7 (N) HEADER BEAM DETAIL 1"=1'-0"I 4 (N) FOOTING DETAIL 2x4 STU 2x4 PL 48 HEA., UNO PER PLAN 2x6 STUDS 2x6 PL 6x8 HEADER, L] LINO PER PLAN 5V (E) UPPER FLOOI WALL TO REMAIN (E) PLYWOOD --- & FLOOR FINISH (N) FLOOR JOIST PER PLAN, EXTEND TO EXTERIOR WALL (E) BASEMENT WALL TO REMAIN (N) SPIRAL STAIR MAIN COLUMN BY OTHERS (N) STEEL BASEPLATE BY OTHERS W/ MIN (4)%"O EXP ANCHOR (6" EMBED) (E) FOOTING----,, #4x1'-4" @ 48" oc EACH SIDE STAGGERED SET IN EPDXY (4" EMBED) INTO (E) SLAB— ON— GRADE/(E)FTG (E) SLAB—ON—GRADE--� ,� \---SAWCUT (E) SLAB, TYP. U (N) FOOTING & REINFORCING tPER PLAN (N) HEADER BEAM DETAIL 18 1 (N) FLOOR INFILL DETAIL 1"=1'-0" 5 (N) FOOTING DETAIL @ SPIRAL STAIR 1"=1'-0" 21 SIMPSON ST2215 — TOP @ EACH END HEADER OR BEAM PER PLAN SOLID BLOCKING @ MID —HEIGHT, WHERE WALL HEIGHT EXCEEDS 8'-0" (2) 10d @ EA END (4) 10d TOENAILS, FLUSH HEADER OR BEAM PER PLAN SIMPSON ST2215 BUILT—UP COLUMN (2) STUDS MIN 2x4 OR 2x6 STUDS @ 16"oc 16d @ 12"oc, TYP @ BUILT—UP COLUMNS HOLDOWN PER PLAN ENGINEERING AM ENGINEERING PLLC 4311 11th Avenue NE, Suite 500 Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineering.works STAMP �S o� waste G1�_11 46161 �FGIS.I.Eg� 'to �PROJEC W V Z Z �_ tto V CD � H O pj UA Z N �p V 0)o Z Q ti O O W U. 0000 (n Q W PREVISIONS NO. DATE 12/5/22 22-220 DATE JOB # AM AM DESIGN CHECKED AM AS NOTED DRAWN SCALE JURISDICTION STAMP SHEET TITLE W B D ETAE R DEPARTMENT NOTES SHEET NO. � GENERAL STRUCTURAL NOTES �121 TYPICAL STUD FRAMING DETAIL 191 3 Simi (E) PLYWOOD (E) PLYWOOD (N) GL BEAM PER PLAN a (E) 2x ROOF L(E) 4x BEAM, SHORE & CUT AS NENE NEEDED & L(N) RAFTERS PER PLAN ATTACH GL BEAM T(N) 2x BLOCKING (N) SIMP HANGER PER PLAN JOISTS @ 4'-0"oc EACH SIDE GL BEAM PER PLAN PER PLAN, TYP �10 7 (N) ROOF BEAM DETAIL 1"=1'-0" 4 (N) BEAM DETAIL (E) ROOF PLY TO REMAIN (E) FLOOR PLYWOOD CUT (E) FLOOR JOISTS HERE TO L(E) ROOF BEAM PER PLAN ACCOMMODATE (N) SPIRAL STAIR (N) SIMP LCE4 CAP (N) KING POST PER PLAN .o. (N) BC40 BASE (N) FLOOR HEADER BEAM (N) 2x FLOOR JOISTS (N) SIMP LUS HANGER @ STAIR INFILL \\,— (E) TRUSSES (N) GL BEAM PER PLAN TO REMAIN 11 8 (N) ROOF DETAIL 1"=1'-0" 5 (N) FLOOR DETAIL @ SPIRAL STAIR (N) 4x RIDGE BEAM PER PLAN (N) ECCQ CAP NOTE: ROOF RAFTERS NOT SHOWN FOR CLARITY (N) PLYWOOD (N) DBL BEVELED TOP PL TO REMAIN (N) SLOPED SEAT (N) POST °' PER PLAN SIMP LUS28, TYP �El SHOP (N) 4x RIDGE BEAM PER PLAN (E) 2x ROOF RAFTERS PER PLAN, SHORE & CUT AS NEEDED TO INSERT (N) GL BM (N) GLULAM BEAM PER PLAN _V_(N) HANGER PER PLAN �12 9 (N) ROOF DETAIL 1"=1'-0" g (N) RIDGE BEAM DETAIL 1"=1'-0" 3 ENGINEERING AM ENGINEERING PLLC 4311 11th Avenue NE, Suite 500 Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineering.works STAMP 46161 I�NALv1 �PROJEC Uj V Z Z O N o w — w> cn Q Z N �0 V �o Z Q ti O 0 p W IL 00 (n Q W PREVISIONS NO. DATE 12/5/22 DATE 22-220 JOB # AM AM DESIGN CHECKED Eaa, DRAWN AS NOTED SCALE � JURISDICTION STAMP � SHEET TITLE W B Mar 08D ET, 6N DEPARTMENT NOTES SHEET NO. S1m2 (E) FOOTING (E) FOOTING (E) FIREPLACE I— L (E) FTG (E) FTG I J L— (N) CONCRETE SLAB PER ARCH (E) CONCRETE SLAB -ON -GRADE (E) POST & FOOTING, CONTRACTORTO VERIFY KEEP (E) WALL-----"' (E) FOOTING 1 /S1.1 �S J (E) CONCRETE SLAB -ON -GRADE 0 sT (E) FOOTING (E) CONCRETE SLAB -ON -GRADE (E) FOOTING A° S (E) FOOTING UP I — I I I I I I (E) FOOTING, CONTRACTOR TO VERIFY N �6' FTG 1 I � I lC:� C4 _ I (E) FOOTING, CONTRACTOR TO VERIFY (E) CONCRETE SLAB -ON -GRADE L S Cps N F2�01\ �r 2/S1.1 n I (E) FOOTING F ts0 (N) SPIRAL STAIRCASE BY OTHERS 1. FOOTING SCHEDULE: F2.0 IS 2'-0"x2'-0"x10" DEEP W/ (4) #5 BARS EA WAY; SEE ARCH FOR DIMENSIONS. 2. SEE SHEETS S1.X FOR DETAILS. 3. WALLS SHOWN ARE IN LOWER FLOOR. 4. SEE ARCH FOR EXTENT OF REMODEL WORK; CONTRACTOR TO VERIFY (E) STRUCTURE IS AS SHOWN. ENGINEERING AM ENGINEERING PLLC 4311 11th Avenue NE, Suite 500 Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineering.works IIIIIIIIIIIIIIIIIIIIISTAMP �PROJ W V Z Z O N O oW 0) w> o� Z N In � p V CDIn Z Q ti O O W U. 00 p V) Q W PREVISIONS NO. DATE 12/5/22 22-220 DATE JOB # AM AM DESIGN CHECKED AM AS NOTED DRAWN SCALE JURISDICTION STAMP IIIIIIIIIIIIIIIIIIIIISHEET TITLE F0UN13FkEh@N PaL 2023 MONDS E SERVICES DEPARTMENT SHEET NO. FOUNDATION PLAN i4"=1'-0" 3 S11 (E) DECK �F------ ------ 1 1JF -II I IIII� —I— III IIII I III L � (N) OUTSIDE PATIO 11I11 III II L — -L -L - (E) DECK STAIR III II� III--�1� II� III I� �11 SPIRAL STAIRCASE THEIRS FLOOR JOISTS AS IN TO ACCOMMODATE ;TAIR 'CH FOR DIMENSIONS. EET S1.1 FOR DETAILS. BELOW FRAMING ARE SHOWN IN HIDDEN LINES (LOWER FLOOR WALLS). ABOVE FRAMING ARE SHOWN IN SOLID LINES (MAIN FLOOR WALLS). 'CH FOR EXTENT OF REMODEL WORK; CONTRACTOR TO VERIFY (E) STRUCTURE IS AS SHOWN. AM ENGINEERING AM ENGINEERING PLLC 4311 11th Avenue NE, Suite 500 Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineering.works IIIIIIIIIIIIIIIIIIIIISTAMP �E MENG llz�S �oF wASg4 "rzt,�- r1d 46161 ��GISTER�� SI�NALEl` IIIIIIIIIIIIIIIIIII11PROJ W C Z Z O N o w> o� OC Z Ncjj �p V CD in Z Q ti O 0 0 W IL 000 V) Q W PREVISIONS NO. DATE 12/5/22 22-220 DATE JOB # AM AM DESIGN CHECKED AM AS NOTED DRAWN SCALE JURISDICTION STAMP IIIIIIIIIIIIIIIIIIIIISHEET TITLE UPPERF@?JbR FRAMI E &OEOs S N DEPARTMENT SHEET NO. S12 a Ef> a 0 UPPER FLOOR FRAMING PLAN i4"=1'-0" 1 3 1 DN (E) FIREPLACE W —(EJ HDR BM TYP— 2x ROOF RAFTERS z(E) 2x ROOF RAFTERS L� KEEP (E) POST, CONTRACTOR TO w VERIFY m PROVIDE (N) RIDGE w BEAM WHERE LOAD BEARING WALL TO BE REMOVED, CONTRACTOR TO ^ VERIFY = 3/S1.2 m 0 J J 2x ROOF RAFTERS 2x ROOF RAFTER rl r� II II II II II II II II II (E) 2x ROOF RAFTERS I (N) I-Ub4b—�< C'� HGR 'r SLOPING (N) GL 3Yx9 (N) LSSR41OZ I HGR (E) 2x ROOF RAFTERS f� N 6/S1.2 N °sue < Ln v (N) GL 3Yx9 N F F (N) HUCQ410 000 HGR � II (E) ROOF TRUSSES II III - III °II I ILL J� III ------------- I �I II II II II II (E) ROOF TRUSSES I Ir F II I L�F L � II I ca— cn II I I� I0 = l II I� II II \ I �I L II (E) ROOF TRUSSES II II II II II II II II I L---� �E) BEAM (E) 2x ROOF RAFTERS (E) ROOF ACCESS HATCH -C) BEAM > N (E) 2x ROOF RAFTERS M Q W I' I �\ 0 uP��l I� I I� I I� I I� H ;E) 2x ROOF RAFTERS CL—=J j Q W m (E) DECK BELOW (E)I SKYLIGHT NOTES: 1. SEE ARCH FOR DIMENSIONS. 2. SEE SHEETS S1.X FOR DETAILS. 3. WALLS SHOWN IN HIDDEN ARE ON UPPER FLOOR. 4. SEE ARCH FOR EXTENT OF REMODEL WORK; CONTRACTOR TO VERIFY (E) STRUCTURE IS AS SHOWN. /AM\/\/\ ENGINEERING AM ENGINEERING PLLC 4311 11th Avenue NE, Suite 500 Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineering.works STAMP �PROJ W C Z Z O N o W > o OC Z Ncjj �p V CD in Z Q ti O V) Q LJJ PREVISIONS NO. DATE 12/5/22 22-220 DATE JOB # AM AM DESIGN CHECKED AM AS NOTED DRAWN SCALE � JURISDICTION STAMP � SHEET TITLE ROOF a g" - G RM ME CNRNM EV SERVICES D ENT � SHEET NO. ROOF FRAMING PLAN Y411=1 1-011 1 3 S23