Loading...
APPROVED FIR FIR2023-0070+Fire_Sprinkler_Plan+8.3.2023_1.26.37_PM+370586711" IAIr(1MIAI(2 I4n'1 SITE PLAN N.T.S 425.00' 416.00' 407.50' 405.00' 395.00' SECTION N.T.S N W S S LIMITS OF AREA NOTES FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT BUT WILL MAINTAIN LISTED HEAD SPACING. E ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL REV I BY ICHK'DI DATE I DESCRIPTION LIMITS OF AREA OF DISTURBANCE EROSION CONTROL SETBACKS HEAD LAYOUT MAY BE DIFFERENT THEN PRINT DUE TO LIGHT AND/OR HEAT REGISTER LOCATIONS BUT WILL MAINTAIN LISTED HEAD SPACINGS Main control valve Rubber -faced check valve Drain and test connection FLOW TF,5-r 5UMMMY Static 82 PSI Residual 20 PSI Flow 1000 GPM _ Pro ert Line :IN 1" Water Meter Pressure au e 2y '---,Water flow detector i" "� Pressure To automatic sprinkler system Approved * Rubber -faced check valves are optional. DFM Chas gust South County Fire RISER SCHEMATIC Date: 08/10/2023 N.T.S 08-10-2023 PLAN REVIEW NOTES: APPROVED WITH CONDITIONS: 1. Approved set of plans must be on site at the time of inspection. Failure to provide the approved plan may result in a re -inspection fee. System drain(s): SEE CONDITION NOTED AT RISER. If riser is above lowest grade, 2nd drain required and signage at riser indicating location is required. Systems required signage IAW NFPA 13D. 2. Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater than 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area.. All fuel fired appliances except attics if above all living areas. DFM Burt HYDRAULIC CALCULATION SUMMARY FIRE SUPPRESSION DESIGN NOTES 1. CODES, STANDARDS AND APPROVALS DESIGN, INSTALLATION, AND TESTING SHALL CONFORM TO THE FOLLOWING 1.1 NFPA-13D (NFPA 2016 EDITION) 1.2 NATIONAL FIRE PROTECTION ASSOCIATION #13D 2.0 DESCRIPTION OF WORK THE FOLLOWING FIRE PROTECTION SYSTEMS ARE INCLUDED IN THIS SECTION OF 2.1 NEW FLOW -THROUGH SPRINKLER SYSTEM 2.2 RESIDENTIAL LEVEL'S DESIGN DENSITY OF 0.05 USGPM/SQFT 2 HEAD CALC (16'x16') DESIGN DENSITY OF 0.05 USGPM/SQFT 1 HEAD CALC (20'x20') 3.0 WATER SUPPLY INFORMATION STATIC PRESSURE: 82 PSI RESIDUAL PRESSURE: 20 PSI @ 1000 USGPM 4.0 MATERIALS & EQUIPMENT ALL FIRE PROTECTION MATERIALS AND EQUIPMENT INSTALLED AS PART OF THIS CONTRACT SHALL BE BE CUL LISTED AND FULLY CONFORM TO NFPA STANDARDS 4.1 CPVC FOR SIZES 34" - 2" UNLESS NOTED FITTING'S GLUED OR GROOVED 4.2 HANGERS AND SUPPORTS ALL HANGERS AND SUPPORTS SHALL BE CUL LISTED FOR FIRE PROTECTION USE AND MEET THE NFPA REQUIREMENTS. ALL HANGER AND SUPPORTS TO BE INSTALLED IN ACCORDANCE WITH NFPA AND THE MANUFACTURER'S SPECIFICATIONS. .0 D4 REQUIRE PROTECTION P3 18 D 8.2.3.Ia�S F DO NOT REQUIRE PROTECTION NFPA- 3. SPRINKLERS ARE SPACED TO A MAX OF 16'x16' (256 SQ.FT.) 4. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE PER NFPA-13D 8.3.5. DENSITY LOCATION REQ'D FLOW AT REQ'D PRESSURE EXCESS RESIDUAL CALCULATION USGPM/SQ.FT. INFLOW NODE AT INFLOW NODE AT INFLOW NODE SAFETY FACTOR 16'xl6' L.H 0.05 USGPM/SQ.FT. / 2 HEAD CALC UPPER FLOOR 33.14 US GPM 51.27 PSI 30.62 PSI 37.3% 20'x20' L.H 0.05 USGPM/SQ.FT. / 1 HEAD CALC UPPER FLOOR 26.91 US GPM 58.55 PSI 23.38 PSI 28.5% NMI AFCON 515 DOUBLE OFFSET HANGER INSULATION CVPC PIPE BY OTHERS HARDENED HEX HEAD SELF THREADING SCREW STAPLE IS FURNISHED WITH THE HANGER. LAIR GARGCO #2530180 OFFSET CPVC HANGER tv� IQW6d (UPPER FLOOR ONLY) L CEILING HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. INSULATION DETAIL N.T.S WASHINGTON STATE 1 CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS i John Shakespeare j 7566-0908-A*-H Level 1 Eclipse Fire Sprinklers, LLC r ECLIPFS783DP 1I i i Jah, 9 .fha*ospaty Expires i Signature DEC 31, 23 ; i========== =======A HEX HEAD SELF TAPPING SCREW CPVC DOUBLE FASTENER STRAP TOLCO FIG. #24 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. HANGER DETAILS N.T.S ECLIPSE FIRE SPRINKLERS SINGLE FAMILY FLOW -THROUGH SPRINKLER SYSTEM FIR2023-0070 RECEIVED Aug 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: PROJECT: JS ECLIPSE FIRE SPRINKLERS, LLC DRAWN BY: VA I SV I LA RESIDENCE JS 111 8TH AVE N ALGONA, WA 98001 CHECKED BY: 17125 69TH P 1 WEST, E D M O N DS, WA 98026 HELLO@ECLIPSEFIRE.COM 206-747-3105 DATE: JOB# DRAWING SHEET: REV: 31JULY,2023 FIRE PROTECTION SCALE: PLAN 10 F 2 1 AS SPECIFIED I 65'-0" 1 I 9'-9" 12'-6- I 3'-0- 12'-6- I 5'-3" N LOWER FLOOR PLAN SCALE: 1118 ==1'-0" N MAIN FLOOR PLAN SCALE: 111r HYDRAULIC NOTES NO. OF SPRINKLERS: DESIGN DENSITY: Q Qrj AREA OF DISCHARGE: 400 SQ.F SYSTEM DEMAND: 21.91 GPM RESIDUAL PRESSURE 0 BASE OF RISER: 51.84 PSI HYDRAULIC NOTES NO. OF SPRINKLERS: DESIGN DENSITY: Q Qj AREA OF DISCHARGE: 51 2 SQ. FT SYSTEM DEMAND: 28.14 GPM RESIDUAL PRESSURE © BASE OF RISER: 43.52 PSI II L — L — BATH BEDROOM I BATH INSPECTOR NOTE: AT THE TIME OF THIS PLAN REVIEW OUR STANDARD WAS NOT ACTIVE PER OUR ADMIN. COVERED DECKS SO NOT REQUIRE PROTECTION PER NFPA 13D. DFM BURT I I I I COVERED DECK TREx : © OeD \ 5 10 -3 �.. O 1" DN- : -3 4 -5 BEDROOM 3 6 1" RISER RDN INSPECTOR NOTE: BUCKET TEST HEADS. INSPECTOR NOTE: BUCKET TEST HEAD GPM. N UPPER FLOOR PLAN SCALE: 1118" =1'-0" COVERED DECK 5'-9 20 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS st John Shakespeare 7566-0908-A*-H Level 1 ; RECEIVED Eclipse Fire Sprinklers, LLC a � ECLIPFS783I]P a i Aug 08 2023 i . oho Sha*ospeww Expires iCITY OF DEC i , a3 DEVELOPMENT SERVICES � Slgnatura � `mmmmam=kmmmmmmmmm DEPARTMENT NOTES REV BY CHK'D DATE DESCRIPTION c �T�I �T r�r �T E S � ��JL� JC1�� � �JLV �� � JL � JL� FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT SYM CNT TYPE METAL TEMP K NPT MFG. MODEL# ESCUTCHEON BUT WILL MAINTAIN LISTED HEAD SPACING. ® 32 PENDENT (16'x16') BRASS 1620 4.9 1/2" SENJU SS8464 CONC. O S ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED O 03 PENDENT (20'x2O')l BRASS 1620 4.9 1/2" SENJU SS8464 CONC. DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD 35 TOTAL HEADS COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... W ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL ECLIPSE FIRE SPRINKLERS ECLIPSE FIRE SPRINKLERS, LLC 111 8TH AVE N ALGONA, WA 98001 H ELLO@ ECLI PSEFI RE.COM 206-747-3105 DESIGNED BY: PROJECT: JS DRAWN BY: JS CHECKED BY: DATE: 31 J U LY, 2023 SCALE: AS SPECIFIED VAISVI LA RESIDENCE 17125 69TH PI WEST, EDMONDS, WA 98026 FIRE PROTECTION JOB# DRAWING SHEET: REV: PLAN 2 of 2 1