REVIEWED RESUB2 BLD2023-0562+Structural_Calculations+9.12.2023_4.03.55_PM+3778932Exceptional %-Enqineerinf� CS2018 Ver 2021.03.22 JOB TITLE Pernack Crystal Falls JOB NO. 220072 SHEET NO. CALCULATED BY Karen M. Stoner DATE 9/7/23 CHECKED BY ADDITIONAL STRUCTURAL CALCULATIONS FOR Pernack Crystal Falls SINGLE FAMILY DWELLING ADDITION '.3 Karen M Stoner wc�''°11,1.11.s I17-11%9:1 I F O R T E W E R JOB SUMMARY REPORT 220072 Pernack Crystal Falls Level Member Name Results Current Solution Comments Typical Header Passed 2 piece(s) 2 x 8 DF No.2 Ridge Beam Passed 2 piece(s) 2 x 12 DF No.2 Beam at edge of (E) Structure Passed 2 piece(s) 2 x 12 DF No.2 ForteWEB Software Operator Job Notes Karen Stoner E2# 220072 Exceptional Engineering Pernack - Crystal Falls (425) 444-6901 karen@exceptionalengineering.com 9/8/2023 1:46:52 AM UTC ForteWEB v3.6 Weyerhaeuser File Name: 220072 Pernack Crystal Falls Page 1 / 4 -iAI FQRTEW EB MEMBER REPORT PASSED Level, Typical Header 2 piece(s) 2 x 8 DF No.2 Overall Length: 6' 9" L 6' 6" 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 586 @ 0 2813 (1.50") Passed (21%) 1.0 D + 1.0 S (All Spans) Shear(lbs) 459 @ 8 3/4" 3002 Passed (15%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 988 @ T 4 1/2" 2576 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl.(in) 0.023 @ T 4 1/2" 0.225 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl.(in) 0.053 @ T 4 1/2" 0.313 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • A 5.3% decrease in the moment capacity has been added to account for lateral stability. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - DF 1.50" 1.50" 1.50" 332 253 586 None 2 - Trimmer - DF 1.50" 1.50" 1 1.50" 332 253 586 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) End Bearing Points Bottom Edge (Lu) End Bearing Points Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 9" N/A 5.5 1 - Uniform (PSF) 0 to 6' 9" 3' 12.0 - Typical Wall 2 - Uniform (PSF) 0 to 6' 9" 3' 19.0 25.0 Roof Load Member Notes Typical Header System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Karen M. Stoner, P.E. ForteWEB Software Operator Job Notes Karen Stoner E2# 220072 Exceptional Engineering Pernack - Crystal Falls (425) 444-6901 karen@exceptionalengineering.com 9/8/2023 1:46:52 AM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Weyerhaeuser File Name: 220072 Pernack Crystal Falls Paget/4 -iAI FQRTEW EB MEMBER REPORT PASSED Level, Ridge Beam 2 piece(s) 2 x 12 DF No.2 Overall Length: 8' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1878 @ 7' 10" 4219 (2.25") Passed (45%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1324 @ 1' 4 3/4" 4658 Passed (28%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3463 @ 4' 1" 5458 Passed (63%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.034 @ 4' 1" 0.375 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.062 @ 4' 1" 0.500 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Stud wall - DF 5.50" 4.25" 1.50" 887 1123 2010 1 1/4" Rim Board 2 - Stud wall - DF 3.50" 2.25" 1 1.50" 851 1077 1928 1 1/4" Rim Board • Kim Boara is assumes to carry all ioaas appl eo oirectiy above it, Dypassng the merroer Deng aesignea. Lateral Bracing Bracing Intervals Comme Top Edge (Lu) 7' 10" o/c Bottom Edge (Lu) 7' 10" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 1 1/4" to 7' 10 3/4" N/A 8.6 1 - Uniform (PSF) 0 to 8' (Front) 11' 19.0 25.0 Roof Load Member Notes Ridge Beam 0 System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Neyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Neyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to qww.weyerhaeuser.com/woodproducts/document-library. the product application, input design loads, dimensions and support information have been provided by Karen M. Stoner, P.E. ForteWEB Software Operator Job Notes Karen Stoner E2# 220072 Exceptional Engineering Pernack - Crystal Falls (425) 444-6901 karen@exceptionalengineering.com 9/8/2023 1:46:52 AM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Weyerhaeuser File Name: 220072 Pernack Crystal Falls Page 3/4 -iAIFORTEWEB MEMBER REPORT Level, Beam at edge of (E) Structure 2 piece(s) 2 x 12 DF No.2 PASSED Overall Length: 11' 1' 10 6' I 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1828 @ 2" 4463 (3.50") Passed (41%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 1266 @ 1' 2 3/4" 4050 Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 4240 @ 5' 6 1/2" 4746 Passed (89%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.061 @ 5' 6 1/2" 0.358 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 1 0.174 @ 5' 6 1/2" 1 0.538 1 Passed (L/741) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Stud wall - SPF 3.50" 3.50" 1.50" 1183 443 416 1828 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 1183 443 416 1828 Blocking • tsiocKmg Naneis are assumeo to carry no ioaas appnea airecay anove tnem ano the run ioao is appnea to the memner Ding oesigneo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 77 o/c Bottom Edge (Lu) 11' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 11' 1" N/A 8.6 1 - Uniform (PSF) 0 to 11' 1" (Front) 2' 17.0 40.0 Floor Load 2 - Uniform (PSF) 0 to 11' 1" (Top) 10' 12.0 - Typical Wall 3 - Uniform (PSF) 0 to 11' 1" (Top) 3' 17.0 25.0 Roof Load Member Notes Beam at edge of (E) Structure System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Karen M. Stoner, P.E. ForteWEB Software Operator Job Notes Karen Stoner E2# 220072 Exceptional Engineering Pernack - Crystal Falls (425) 444-6901 karen@exceptionalengineering.com 9/8/2023 1:46:52 AM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Weyerhaeuser File Name: 220072 Pernack Crystal Falls Page 4/4 Exceptional Engineering 1730 Labounty Drive, Ste 9-63 Ferndale, WA 98248 (425) 444-6901 Wind Loads: Ultimate Wind Speed Nominal Wind Speed Risk Category Exposure Category Enclosure Classif. Internal pressure Directionality (Kd) Kh case 1 Kh case 2 Type of roof ASCE 7- 16 98 mph 75.9 mph B Enclosed Building +/-0.18 0.85 0.701 0.665 Monoslope Topographic Factor (Kzt) Topography Flat Hill Height (H) 80.0 ft Half Hill Length (Lh) 100.0 ft Actual H/Lh = 0.80 Use H/Lh = 0.50 Modified Lh = 160.0 ft From top of crest: x = 50.0 ft Bldg up/down wind? downwind H/Lh= 0.50 K, = 0.000 x/Lh = 0.31 K2 = 0.792 z/Lh = 0.16 K3 = 1.000 At Mean Roof Ht: Kzt = (1+KjK2K3)^2 = 1.00 JOB TITLE Pernack Crystal Falls JOB NO. 220072 SHEET NO. CALCULATED BY Karen M.Stoner DATE 3/9/22 CHECKED BY DATE Resubmitted for clarity, no revisions ESCARPMENT V(z) Z - Speed-up V(z) X(UU*nd) x(dowmvind) HI2 H 2D RIDGE or 3D AXISYMMETRICAL HILL Gust Effect Factor Flexible structure if natural frequency < 1 Hz (T > 1 second). h = 25.0 ft If building h/B>4 then may be flexible and should be investigated. B = 35.0 ft h/B = 0.71 Rigid structure (low rise bldg) /z (0.6h) = 30.0 ft G = 0.85 Using rigid structure default Rigid Structure Flexible or Dynamically Sensitive Structure e = 0.33 34icy (n,) = 0.0 Hz f = 320 ft Damping ratio ((3) = 0 Zmin = 30 ft /b = 0.45 c = 0.30 /a = 0.25 go, 9v = 3.4 Vz = 63.2 Lz = 310.0 ft Nj = 0.00 Q = 0.90 Rn = 0.000 lz = 0.30 Rh = 28.282 n = 0.000 h = 25.0 ft G = 0.87 use G = 0.85 RB = 28.282 q = 0.000 RL = 28.282 q = 0.000 9R = 0.000 R = 0.000 Gf = 0.000 Exceptional Engineering JOB TITLE Pernack Crystal Falls 1730 Labounty Drive, Ste 9-63 Ferndale, WA 98248 JOB NO. 220072 SHEET NO. (425) 444-6901 CALCULATED BY Karen M. Stoner DATE 3/9/22 CHECKED BY DATE Resubmitted for clarity, Enclosure Classification no revisions Test for Enclosed Building: Ao < 0.01Ag or 4 sf, whichever is smaller Test for Open Building: All walls are at least 80% open. Ao >_ 0.8Ag Test for Partially Enclosed Building: Predominately open on one side only Input Test Ao 500.0 sf Ao >_ 1.1Aoi NO Ag 600.0 sf Ao > 4' or 0.01Ag YES Aoi 1000.0 sf Aoi / Agi <_ 0.20 YES Building is NOT Agi 10000.0 sf Partially Enclosed Conditions to qualify as Partially Enclosed Building. Must satisfy all of the following: Ao >_ 1.1Aoi Ao > smaller of 4' or 0.01 Ag Aoi / Agi <_ 0.20 Where: Ao = the total area of openings in a wall that receives positive external pressure. Ag = the gross area of that wall in which Ao is identified. Aoi = the sum of the areas of openings in the building envelope (walls and roof) not including Ao. Agi = the sum of the gross surface areas of the building envelope (walls and roof) not including Ag. Test for Partially Open Building: A building that does not qualify as open, enclosed or partially enclosed. (This type building will have same wind pressures as an enclosed building. Reduction Factor for large volume partially enclosed buildings (Ri) If the partially enclosed building contains a single room that is unpartitioned , the internal pressure coefficient may be multiplied by the reduction factor Ri. Total area of all wall & roof openings (Aog): Unpartitioned internal volume (Vi) : Ground Elevation Factor Me) 0 sf 0 cf Ri = 1.00 Grd level above sea level = 0.0 ft Ke = 1.0000 Constant = 0.00256 Adj Constant = 0.00256 Exceptional Engineering 1730 Labounty Drive, Ste 9-63 Ferndale, WA 98248 (425) 444-6901 Seismic Loads: IBC 2018 Risk Category : II Importance Factor (1) : 1.00 Site Class : D - code default JOB TITLE Pernack Crystal Falls JOB No. 220072 SHEET NO. CALCULATED BY Karen M.Stoner DATE 3/9/22 CHECKED BY DATE Strength Level Forces Resubmitted for clarity, no revisions Ss (0.2 sec) = 129.60 %g S1 (1.0 sec) = 45.80 %g A site specific ground motion analysis is required for seismically isolated structures or with damping systems, see ASCE7 11.4.8 Fa = 1.200 Sms = 1.555 SDS = 1.037 Design Category = D Fv = 1.842 Sm1 = 0.844 Sol = 0.562 Design Category = D Seismic Design Category = D Redundancy Coefficient p = 1.30 Number of Stories: 2 Structure Type All other building system: Horizontal Struct Irregularities:No plan Irregularity Vertical Structural Irregularities:No vertical Irregularity Flexible Diaphragms: Yes Building System: Bearing Wall Systems Seismic resisting system: Light frame (wood) walls with structural wood shear panels System Structural Height Limit: 65 ft Actual Structural Height (hn) =30.0 ft See ASCE7 Section 12.2.5 for exceptions and other system limitations DESIGN COEFFICIENTS AND FACTOR Response Modification Coefficient (R) = 6.5 Over -Strength Factor (no) = 2.5 Deflection Amplification Factor (Cd) : 4 SDs = 1.037 Sol = 0.562 Seismic Load Effect (E) = Eh +/-Ev = p GE +/- 0.2SDs D Special Seismic Load Effect (Em) : Emh +/- Ev = DO CE +/- 0.2SDs D PERMITTED ANALYTICAL PROCEDURE Simplified Analysis - Use Equivalent Lateral Force Analysis Equivalent Lateral -Force Analysis Permittec Building period coef. ((T) = 0.020 Approx fundamental period (Ta) CThn,. = 0.256 sec x= 0.75 User calculated fundamental period (T) = sec Long Period Transition Period (TL) = ASCE7 map = 8 = 1.3Qe +/ 0.207D QE = horizontal seismic force = 2.5Qe +/ 0.207D D = dead loac Cu = 1.40 Tmax = CuTa = 0.359 Use T = 0.256 Seismic response coef. (Cs) = Sdsl/R = 0.160 ASCE7 11.4.8 exception 2 equations used but not less than Cs = 0.044Sdsl = 0.046 USE Cs = 0.160 Design Base Shear V = 0.160W Model & Seismic Response Analysis - Permitted (see code for procedure) ALLOWABLE STORY DRIFT Structure Type: All other structures Allowable story drift Da = 0.020hsx where hsx is the story height below level x Resubmitted for clarity, no revisions E2 #: 220072 PROJECT: Pernack Crystal Falls Cs: 0.160 k = 1.00 (ASCE E . 12.8-12 VtKI I(:AL JtIJMI(: I-UK(:t UI51 KIt3U I IUN (ASCE 12.8.3) Level Height DL PL Floor Area Weight whk Cv Story Shear % Total ft) (psf) (psf) (sq.ft.) (Ibs) (k-ft (12.8-12) (Ibs) psf Roof 30.0 30.0 5.0 3538 123830 3714.9 0.772 26598 7.5 77.2% (E) 2nd/lwI 12.0 17.0 10.0 3068 82836 994.0 0.206 7117 2.3 20.6% (N) Iwr roo- 12.0 30.0 5.0 250 8750 105.0 0.022 752 3.0 2.2% 215416 4813.9 1.0 34467 12.8 E2 #: 220072 PROJECT: Pernack Crystal Falls 2015 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC Upper Floor Shear Walls Letter p = 1.3 Number p = shearwall total wall wall perf. wall sum of wall max. opening shear factor .6Fx wind .7Fx seismic p p max *.7Fx seismic Effective* unit wall Critical Wall Segment Wall L = total L at force transfer/perforated walls segment uniform overtrng. holdown label length height length segments height Co force force factor' force shear type length DL force type (ft) (ft) (ft) (ft) (ft) (lb) (lb) (lb) (plf) (ft) (plf) (lb) 2 (E) to remain 1.00 3 (E) to remain 1.00 A (E) to remain 1.00 B (E) to remain 1.00 Main Floor Shear Walls Number p - Letter p - shearwall total wall wall perf. wall sum of wall max. opening shear factor .6Fx wind .7Fx seismic p p max *.7Fx seismic Effective* unit wall Critical Wall Segment Wall L = total L at force transfer/ erforated walls segment uniform overtrng. holdown label length height length segments height Co force force factor' force shear type length DL force type ft ft ft ft ft(lb) (lb) (lb) If ft If(lb) 1 4 9 1.00 720 752 1.30 977 252 P4 141 2075 A (HDU5) 2 (E) 1.00 0 16857 1.30 21915 2 (E) w/ increase 0 17233 1.30 22403 2% increase, OK per IEBC 502.5 3 (E) to remain 1.00 A (E) to remain 1.00 1680 16857 1.30 21915 A (E) w/ increase 1680� 17233 1.30 22403 2% increase, OK per IEBC 502.5 B (E) to remain 1.00 497 16857 1.30 21915 B (E) w/ increase 1666 17233 1.30 22403 2% increase, OK per IEBC 502.5 102% OK per IEBC 502.5 * Note: Effective unit shear includes magnification of force to account for reduction in wall capacity due to perforated wall or Aspect Ratio Factor < 1.0 ( example: .7*capacity = force/.7)