Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-0529_Manufacturer_Specifications_and_Installation_Instructions_4.22.2024_11.00.18_AM_4210603
126S Preferred Series Single -Stage Air Conditioner with Puron® Refrigerant 1-1/2To5Tons Product Data This unit has been designed utilizing Bryant's Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. STANDARD FEATURES Bryant Industry leading Features / Benefits Efficiency • 13.8 - 16.0 SEER2 (14 - 16.5 SEER) / 11.2 —13.0 EER2 (11.2 - 13.0 EER) • Microtube Technology refrigeration system • Indoor air quality accessories available Reliability • Puron refrigerant - environmentally sound, layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Filter drier Durability DuraGuard P1usTM Protection Package: won't deplete the ozone • Solid, Durable sheet metal construction • Steel louver coil guard • Baked -on, complete outer coverage, powder paint Applications • Long line — up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.) • Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits. Features 18 24 30 36 42 48 49 60 61 Puron Refrigerant X X X X X X X X X SEER2 (Range depending on indoor combination) 14.3 - 16 14.3 - 16 14.3 - 16 14.3 - 16 13.8 - 15 13.8 - 15 14 - 16 13.8-15 14 - 16 Scroll Compressor X X X X X X X X X Field Installed Filter Drier X X X X X X X X X Front Seating Service Valves X X X X X X X X X Internal Pressure Relief Valve X X X X X X X X X Internal Thermal Overload X X X X X X X X X Long Line Capability X X X X X X X X X Low Ambient Capability with Kit X X X X X X X X X High Pressure Switch X X X X X X X X X Low Pressure Switch X X X X X X X X X Compressor Sound Blanket X X X X X X X X X Louvered Coil Guard X X X X X X X X X 126S: Product Data MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8,9 10 11 12 1 2 6 S A Major Series t N Voltage g 0 Open 18 Cooling Capacity 9 p y 0 0 W Product Tier & SEER2 OD Design Type 9 yp Feature Special Region g Family Refrigerant Feature 1=AC 2 = Preferred 6 = 16 S = Single Stage A-Z=Major Series N = 20-230-1 018 = 18,000 BTUH (1.5 Tons) 0 = Standard 0 = Standard W=Standard R410A SEER2 or 208/230-1 024 = 24,000 BTUH (2 Tons) SW AC 030 = 30,000 BTUH (2.5 Tons) 036 = 36,000 BTUH (3 Tons) 042 = 42,000 BTUH (2 Tons) 048 = 48,000 BTUH (4 Tons) 049 = 48,000 BTUH (4 Tons) 060 = 60,000 BTUH (5 Tons) 061 = 60,000 BTUH (5 Tons) CATALOG ORDERING NUMBERS Size Model Number 18 126SAN0180OW 24 126SAN0240OW 30 126SAN03000W 36 126SAN0360OW 42 126SAN0420OW 48 126SAN0480OW 49 126SAN0490OW 60 126SAN06000W 61 126SAN06100W Peron.TM �L Ufa of :fw AI1RI CeniraE Marty mdi's e _ C US maNvei a manact partkipation in ti,o Quality poropam Fa vednCatwn 1509001 1 difi—on larmd.duai proaa<rc. go to �woion�. *wx.arlddiraelary.ary. Physical Data Unit Size 18 24 30 36 42 48 49 60 61 Compressor Type Scroll REFRIGERANT Puron (R-410A) Control TXV (Puron Hard Shutoff) Factory Charge lb (kg)' 4.70 (2.13) 5.60 (2.54) 6.60 (2.99) 6.80 (3.08) 8.10 (3.67) 8.10 (3.67) 12.40 (5.62) 10.10 (4.58) 14.50 (6.58) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2050 2600 2575 3700 3890 3890 4090 4260 4320 Motor HP 1/12 1/10 1/10 1/4 114 1/4 1/3 1/4 1/3 Motor RPM 1100 1100 1100 1100 1100 1100 800 1100 800 COND COIL Face Area (Sq ft) 11.5 14.7 19.4 21.5 17.2 17.2 30.1 21.5 30.1 Fins per In. 25 25 25 25 20 20 20 20 20 Rows 1 1 1 1 2 2 2 2 2 Circuits 3 4 5 6 8 8 10 9 12 VALVE CONNECT. (In. ID) Vapor 314 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Liquid 3/8" REFRIGERANT TUBES* (In. OD) Rated Vaport 3/4 3/4 3/4 7/8 7/8 7/8 7/8 1 1/8 1 1/8 Rated Liquid Line$ 3/8" *. For 15 ft. Line Set t.Units are rated with 25 ft. (7.6m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. $.See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron® Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Table 1— Maximum Total Equivalent Length* Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid LineDiam. ne Dia AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit BELOW Indoor Vertical Se partition ft (m) 0-56-10 (0-1.5) (1.83.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-1 5.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 1/4 150 150 125 100 100 75 — — - 18000 3/8 5116 250* 250* 250* 250* 250* 250* 250* 225* 150 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 75 75 75 50 50 -- — — -- 24000 3/8 5/16 250* 250* 250* 250* 1 250* 225* 175 1 125 100 3/8 1 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- — 30000 3/8 5/16 175 225* 200 175 125 100 75 — -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 36000 3/8 5/16 175 150 150 100 100 100 75 — -- 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 42000 3/8 5116 125 100 100 75 75 50 — — -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 150 48000 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- 60000 3/8 3/8 250* 250* 250* 225* 190 150 110 — *.Maximum actual length not to exceed 200 ft (61 m) t.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Table 2 — Maximum* Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Dlam. w/TXV AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.6) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 1/4 175 250* 250* 250* 250* 250* 250* 250* 18000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 100 125 175 200 225* 250* 250* 250* 24000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- — -- -- -- -- -- 30000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 36000 3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 42000 318 5/16 175 200 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 48000 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 60000 318 3/8 250* 250* 250* 250* 250* 250* 250* 250* *.Maximum actual length not to exceed 200 ft (61 m) t.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data Table 3 — Refrigerant Charge Adjustments Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft X total length) — (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of lineset* using existing 1/4" liquid line. What charge adjustment is required? Formula:(.27 oz/ft X 15ft) — (9 oz) = (495) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment? Formula:(.40 oz/ft. X 45ft) — (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method. * When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information. Long Line Applications An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. Table 4 — AC with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m) Table 5 — AC with Puron® Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Residential Piping and Long Line Guideline for details Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron® refrigerant: Table 6 — Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1-Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (in. OD) 1/2 Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 1-Stage AC with Puron® 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 1 2 3 5 6 7 8 9 11 18 3/8 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 5/8 0 1 2 2 3 3 4 5 5 24 3/8 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 30 3/8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 8 9 10 12 36 3/8 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 3 4 4 5 6 42 3/8 7/8 0 0 1 1 1 2 2 2 3 11/8 0 0 0 0 0 0 0 0 0 3/4 0 1 2 3 4 5 5 6 7 48,49 3/8 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 60,61 3/8 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data ACCESSORIES KIT NUMBER KIT NAME 18 24 30 36 42 48 49 60 61 KSAFT0101AAA FRZ THERM KIT X X X X X X X X X KAATD0101TDR TIME DELAY KIT (90 second TDR) X X X X X X X X X KAATD0201TDR TIME DELAY KIT (30 second TDR) X X X X X X X X X KSALA0301410 LOW AMBIENT COOLING KIT X X X X X X X X X HC40GQ236 MOTOR, FAN' X X LA01RA339 FAN. X X KSALA1001AAA MOTORMASTER KIT X X X X X X X X X KSAHS2501AAA HARD START KIT X X X X X X X X X KSACY0101AAA CYCLE PROTR KIT X X X X X X X X X KSASF0201AAA SPRT FEET KIT X X X X X X X X X KAALS0201 LLS SOL VALVE KIT X X X X X X X X X KAAWS0101AAA WINTER ST KIT X X X X X X X X X KAACH1701AAA CRKC HTR KIT X X X X KAACH1601AAA CRKC HTR KIT X X X KSATX0201 PUR TXV KIT (For use with copper coils) X X X KSATX0301 PUR TXV KIT (For use with copper coils) X X KSATX0401 PUR TXV KIT (For use with copper coils) X X X X KSBTX0201 PUR TXV KIT (For use with aluminum coils) X X X KSBTX0301PUR TXV KIT (For use with aluminum coils) X X KSBTX0401PUR TXV KIT (For use with aluminum coils) X X X X *.Required for use with low ambient or MotorMaster kits. Rated efficiency will not be met with this accessory installed. X = Accessory Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LOW -AMBIENT COOLING REQUIRED FOR LONG SEA COAST ACCESSORY APPLICATIONS LINE APPLICATIONS APPLICATIONS (Below 55°F/12.8°C) Standard Yes Yes Standard (Within 2 miles/3.22 km) Ball Bearing Fan Motor Standard No Compressor Start Assist Capacitor and Relay Yes Crankcase Heater Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long Line Guideline No MotorMaster® Control or Yest No No Low -ambient Pressure Switch Winter Start Control I Yes$ I No I No *.For tubing set lengths between 80 and 200 ft. (24 and 61 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Residential Split -System Long Line Application Guideline. j .ln units equipped with ECM OD motor, motor and fan needs to be replaced per unit accessory guide to work properly. Unit will not meet AHRI rated efficiency once motor and fan are replaced to use this accessory. $.Required if Low Pressure Switch is factory or field installed. Accessory Description and Usage (Listed Alphabetically) 1. Ball -Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster'5 is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 5. Evaporator Freeze Thermostat An SPST temperature -actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. o. Low -Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0°F (-18°C) when properly installed and also using wind baffles. Instructions provided in accessory kit. Usage Guideline: A Low -Ambient Pressure Switch or MotorMaster® Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). 7. MotorMaster® Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to—10°F/-23.3°C), it maintains condensing temperature at 100°F f10°F (37.8°C f5.5°C). Usage Guideline: A MotorMaster Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. 8.Outdoor Air Temperature Sensor This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for use with compatible Bryant thermostats. 9. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data Accessory Description and Usage (Listed Alphabetically) Continued 10. Support Feet Four or five stick -on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 11. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 12. Time -Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory). When a Time -Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units. 13. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 126S: Product Data AHRI RATINGS For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: wMyBryantRatings Electrical Data UNIT SIZE V/PH OPER VOLTS COMPR FAN MCA MAX FUSET or CKT BRK AMPS MAX MIN LRA RLA FLA 18 208/230/1 253 197 42.6 8.8 0.4 11.4 20.0 24 49.7 9.3 0.6 12.2 20.0 30 71.3 11.7 0.6 15.2 25.0 36 80.1 12.2 1.4 16.7 25.0 42 120.0 25.0 1.52 32.8 50.0 48 120.0 25.0 1.52 32.8 50.0 49 124.0 18.5 2.80 25.9 40.0 60 150.0 25.6 1.40 33.4 50.0 61 140.6 26.3 2.80 35.7 50.0 *.Permissible limits of the voltage range at which the unit will operate satisfactorily f.Time-Delay fuse. FLA- Full Load Amps LRA - Locked Rotor Amps MCA- Minimum Circuit Amps RLA- Rated Load Amps NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1 A -Weighted Sound Power (dBA) UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) RATING 125 250 500 1000 2000 4000 8000 18 74 65.7 66.5 66.5 66.0 62.2 59.6 55.2 24 72 66.9 66.7 69.2 68.4 62.1 59.8 56.8 30 72 68.0 67.4 68.1 68.8 63.5 60.2 55.1 36 74 70.2 70.7 69.3 66.2 61.4 58.8 52.9 42 74 73.6 72.9 71.3 70.0 63.4 60.1 55.1 48 74 73.6 72.9 71.3 70.0 63.4 60.1 55.1 49 72 67.5 64.3 67.8 66.2 59.8 56.7 51.8 60 74 69.9 72.5 71.1 68.9 63.6 59.9 59.0 61 72 64.9 71.5 68.4 69.9 60.3 57.4 54.1 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Charging Subcooling (TXV-Type Expansion Device) UNIT SIZE REQUIRED SL 18 24 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. DIMENSIONS OPERATING SHIPPING SHIPPING SHIPPING UNIT SERIES ELECTRICAL A B C D E F G H I d K WEIGHT WEIGHT LENGTH / WIDTH HEIGHT CHARACTERISTICS (54) INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCHF457.2 INCH MM INCH MM Lbs s Lbs s INCH MM INCH MM 126SA'018'OW A Y N N N 25 3/4 654.0 2811/16 728.7 3/4 19.1 4 7/16 113.0 21 1/4 539.9 9 1/8 231.3 5/16 7.9 3 76.2 12 1/2 12 304.8 11 279.4 127 57.6 141 64.0 28 3/4 730.0 3315/16 862.1 126SA'024'OW A Y N N N 25 3/4 654.0 35 1/2 901.4 3/4 19.1 4 7/16 113.0 21 1/4 539.9 9 1/8 231.3 5/16 7.9 3 76.2 10 1/211 1/2 292.1 15 1/2 393.7 140 63.5 146 66.2 28 3/4 730.0 40 3/4 1034.8 126SW030'OW A Y N N N 31 3/16 792.5 35 1/2 901.4 3/4 19.1 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 15 381.0 16 1/2 419.1 162 73.5 180 81.6 34 1/4 870.0 40 3/4 1034.3 126SA7036'0W A Y N N N 31 3/16 792.5 38 7/8 987.8 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 16 15 381.0 18 112 469.9 177 80.3 198 89.8 34 114 870.0 44 1/8 1120.7 126SA'042'OW A Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 15 381.0 13 112 342.9 201 91.2 221 100.2 34 1/4 870.0 37 5/16 947.9 126SR048'0W A Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 15 381.0 13 1/2 342.9 201 91.2 221 100.2 34 1/4 870.0 37 5/16 947.9 126SA'049.OW A Y N N N 35 889.0 45 11/16 1160.5 7/8 22.2 6 9/16 166.1 28 7/16 722.8 9 1/8 231.3 5116 7.9 3 76.2 18 18 45Z2 19 1/2 495.3 278 126.1 302 137.0 37 13/16 960.0 50 15116 1293.4 126SA'O60'OW A Y N N N 31 3/16 792.5 38 7/8 987.8 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5111 7.9 3 76.2 1515 1/2 393.7 20 508.0 222 100.7 242 1C9.8 34 1/4 870.0 44 1/8 1120.7 126SW061'OW A Y N N N 35 889.0 4511/16 1160.5 7/6 22.2 6 9116 166.1 28 7/16 722.8 9 1/8 231.3 5/16 7.9 3 76.2 17 1/2 444.5 16 1/2 419.1 24 609.6 282 127.9 306 138.8 3713/16 960.0 5015/16 1293.4 W m Y=YES NOTES: N=NO 1. CENTER OF GRAVITY � A so. AIR DISCHARGE ` \ f / AIR IN AIR DISCHARGE F � FIELD POWER SUPPLY CONN. Emil I B 7/8'(022.21 HOLE WITH fl AIR IN -AIR IN 11/8(028.6) KNOCKOUT FIELD CONTROL SUPPLY CONN. OT/8'(022.2) HOLE E LIOU D L/ NE000NN. K J 3 3/4' (96.0) (88.9) I H D Y O C,VAPOR LINE CONN.I so. 1 13/18" r X (d6.71 1/8" C7 S0. (3.2) f 3/ 5) TIE DOWN KNOCKOUTS L PLACES (21 PLACES 2 3/16 AIR IN ..X.. ..Y.. ( 55.61 UNIT SIZE MINIMUM GROUND MOUNTING MINIMUM ROOF -TOP MOUNTING PAD APPLICATION DIMENSIONS PAD APPLICATION DIMENSIONS 23 1/8 587.3 17 7/8 454.6 18.24 25 3/4 654.0 20 7/16 518.5 30,349,618,60 31 3/16 22 1314 583.2 NOTE: ALL DIMENSIONS IN INCH (MM) U.S. ECCN: Not Subject to Regulation (N.S.R.) 49,61 889.5 35 889.0 26 3/4 679.7 SD57024 REV. c CLEARANCES N Clearances (various examples) 0 v v Wall Wall 6" (152.4 mm) ' (609.6) Service 12" (304.8) 24" (609.6) 18" (457.2) ' (304.8) 18" (457.2) U��F1 I 24" (609.6) Service 1213 (304.8) 18" (457.2) 24" Service 52'.4)I 2 12" (304.8) 24" (609.6) Service J Note: Numbers in () = mm Allow 48" above unit IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. DETAILED COOLING CAPACITIES# EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Capacity MBtuh Total System Capacity MBtuh Total System Capacity MBtuh Total System Capac=MBtuhTotal System Capacity MBtuh Total System Capacity MBtuh Total System Total Sens#CFM Total Sens# kW** Total Sens# kW** Total kW** To Sens# kW** Total Sens# kW** 126SAN01 80OW Outdoor EWBkW** 72 (22.2) 21.31 10.36 1.20 20.40 10.07 1.34 19.20 9.59 1.50 18.03 9.23 1.67 17.29 8.89 1.89 15.97 8.46 2.12 67 (19.4) 19.30 12.60 1.21 18.62 12.33 1.35 17.67 11.97 1.51 16.59 11.49 1.68 15.63 11.13 1.89 14.49 10.63 2.13 525 63 (17.2)tt 17.95 12.18 1.22 17.16 11.85 1.36 16.33 11.48 1.51 15.42 11.08 1.69 14.43 10.64 1.90 13.23 10.12 2.13 62 (16.7) 17.67 14.88 1.22 16.88 14.54 1.36 16.04 14.13 1.52 15.12 13.72 1.70 14.42 12.67 1.90 13.44 13.44 2.13 57 (13.9) 17.17 17.17 1.22 16.48 16.48 1.36 15.81 15.81 1.52 15.08 15.08 1.69 14.26 14.26 1.89 13.40 13.40 2.13 72 (22.2) 21.60 10.64 1.22 20.65 10.35 1.36 19.26 9.79 1.52 18.21 9.48 1.70 17.48 9.16 1.91 16.13 8.73 2.15 67 (19.4) 19.59 13.05 1.23 18.80 12.78 1.37 17.90 12.42 1.53 16.77 11.92 1.71 15.82 11.57 1.92 14.63 11.05 2.15 575 63 (17.2)tt 18.20 12.59 1.24 17.41 12.28 1.38 16.56 11.90 1.54 15.61 11.48 1.72 14.59 11.05 1.92 13.46 10.56 2.16 62 (16.7) 17.96 15.52 1.24 17.12 15.18 1.38 16.26 14.76 1.54 15.60 13.72 1.72 14.71 14.71 1.92 13.73 13.73 2.16 57 (13.9) 17.67 17.67 1.25 16.96 16.96 1.38 16.25 16.25 1.54 15.48 15.48 1.72 14.63 14.63 1.92 13.69 13.69 2.15 72 (22.2) 22.07 11.15 1.27 20.94 10.81 1.41 20.10 10.46 1.57 18.61 9.93 1.74 17.76 9.63 1.96 16.36 9.20 2.19 67 (19.4) 20.09 13.92 1.28 19.21 13.65 1.42 18.10 13.12 1.57 16.94 12.73 1.75 16.08 12.40 1.96 14.81 11.92 2.20 675 63 (17.2)tt 18.67 13.40 1.29 17.80 13.07 1.43 16.96 12.68 1.58 15.81 12.17 1.76 14.82 11.80 1.97 13.65 11.31 2.21 62 (16.7) 19.11 16.31 1.29 17.80 17.80 1.43 17.00 17.00 1.58 16.19 16.19 1.76 15.24 15.24 1.97 14.24 14.24 2.20 57 (13.9) 18.48 18.48 1.29 17.71 17.71 1.43 126SAN0240OW 16.95 Outdoor 16.95 1.58 16.12 16.12 1.76 15.21 15.21 1.97 14.23 14.23 2.21 72 (22.2) 27.57 13.26 1.57 26.18 12.90 1.75 25.05 12.32 1.94 23.54 11.77 2.17 22.18 11.36 2.43 20.57 10.75 2.71 67 (19.4) 25.05 16.09 1.59 24.07 15.63 1.76 22.80 15.16 1.95 21.54 14.50 2.17 20.27 14.05 2.42 18.78 13.43 2.71 650 63 (17.2)tt 23.34 15.54 1.60 22.22 15.10 1.76 21.12 14.57 1.95 20.07 14.00 2.17 18.69 13.47 2.42 17.38 12.84 2.70 62 (16.7) 22.92 18.72 1.60 21.85 18.27 1.76 20.78 17.76 1.95 19.71 17.15 2.17 18.41 16.65 2.41 17.08 15.99 2.70 57 (13.9) 21.94 21.94 1.61 21.04 21.04 1.77 20.20 20.20 1.95 19.35 19.35 2.17 18.24 18.24 2.42 17.18 17.18 2.70 72 (22.2) 28.32 14.10 1.63 27.18 13.57 1.81 25.82 13.05 2.02 24.14 12.44 2.24 22.78 11.97 2.50 21.07 11.35 2.78 67 (19.4) 26.04 17.31 1.65 24.86 16.80 1.82 23.60 16.28 2.02 22.13 15.67 2.24 20.82 15.14 2.49 19.23 14.51 2.78 800 63 (17.2)tt 24.28 16.67 1.66 23.09 16.19 1.83 21.91 15.70 2.02 20.61 15.08 2.24 19.27 14.48 2.49 17.78 13.93 2.78 62 (16.7) 23.75 20.45 1.66 22.67 20.01 1.83 21.51 19.43 2.02 20.35 18.67 2.24 18.90 18.89 2.49 18.08 18.08 2.78 57 (13.9) 23.26 23.26 1.67 22.35 22.35 1.83 21.41 21.41 2.02 20.30 20.30 2.24 19.25 19.25 2.49 18.09 18.09 2.78 72 (22.2) 28.69 14.55 1.67 27.56 14.00 1.86 26.18 13.49 2.06 24.28 12.82 2.28 23.01 12.38 2.55 21.28 11.74 2.83 67 (19.4) 26.40 17.98 1.69 25.21 17.54 1.87 23.91 17.00 2.07 22.37 16.37 2.29 21.04 15.86 2.54 19.39 15.18 2.83 900 63 (17.2)tt 24.48 17.42 1.71 23.43 16.92 1.88 22.17 16.32 2.07 20.81 15.72 2.29 19.49 15.20 2.53 17.94 14.48 2.82 62 (16.7) 24.13 21.47 1.71 23.00 21.03 1.88 21.99 20.46 2.07 21.04 21.03 2.29 19.79 19.79 2.54 18.50 18.50 2.83 57 (13.9) 24.06 24.06 1.71 23.10 23.10 1.88 22.12 22.12 2.07 20.89 20.89 2.29 19.81 19.81 2.54 18.49 18.49 2.83 DETAILED COOLING CAPACITIES# CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) Capacity MBtuh Total System Total Sens# kW" 126SAN0300OW 95 (35) 105 (40.6) 115 (46.1) Capacity MBtuh Total System Total Sens# kW** 125 (51.7) CFM EWB Capacity MBtuh Total System kW+ Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Total Sens# Total Outdoor Sens# Total Sens# Total Sens# 72 (22.2) 34.76 16.74 1.98 32.77 16.17 2.19 30.95 15.49 2.42 29.32 14.83 2.70 27.38 14.05 3.00 25.34 13.44 3.36 67 (19.4) 31.61 20.37 1.97 29.89 19.61 2.17 28.37 19.09 2.41 26.81 18.36 2.67 25.00 17.57 2.97 23.16 16.94 3.34 875 63 (17.2)tt 29.29 19.65 1.96 27.62 18.98 2.16 26.31 18.37 2.39 24.85 17.66 2.66 23.15 16.86 2.95 21.49 16.12 3.31 62 (16.7) 28.84 23.81 1.96 27.16 23.16 2.16 25.90 22.56 2.39 24.41 21.83 2.65 22.76 21.00 2.95 21.53 21.53 3.31 57 (13.9) 27.77 27.77 1.96 26.46 26.46 2.16 25.43 25.43 2.39 24.24 24.24 2.65 22.79 22.78 2.96 21.42 21.42 3.31 72 (22.2) 35.51 17.32 2.04 33.61 16.71 2.25 31.63 15.97 2.48 29.74 15.38 2.76 27.77 14.57 3.06 25.70 13.83 3.42 67 (19.4) 32.26 21.30 2.03 30.43 20.51 2.23 28.80 19.98 2.46 27.22 19.25 2.73 25.37 18.43 3.03 23.51 17.69 3.40 990 63 (17.2)tt 29.98 20.55 2.02 28.11 19.83 2.22 26.76 19.21 2.45 25.25 18.49 2.71 23.50 17.66 3.01 21.75 16.90 3.37 62 (16.7) 29.46 25.16 2.02 27.65 24.47 2.22 26.32 23.84 2.45 24.80 23.13 2.71 23.60 23.60 3.01 22.06 22.06 3.38 57 (13.9) 28.86 28.86 2.02 27.37 27.37 2.21 26.29 26.28 2.45 25.04 25.04 2.71 23.48 23.48 3.02 22.10 22.10 3.37 72 (22.2) 35.99 17.93 2.10 34.08 17.27 2.32 32.09 16.50 2.55 30.17 15.86 2.82 28.10 15.11 3.13 25.97 14.36 3.49 67 (19.4) 32.82 22.27 2.09 31.09 21.74 2.30 29.23 20.99 2.53 27.56 20.25 2.79 25.65 19.37 3.10 23.65 18.57 3.45 1125 63 (17.2)tt 30.52 21.46 2.08 28.72 20.67 2.29 27.15 20.12 2.51 25.58 19.39 2.78 23.77 18.53 3.08 21.95 17.75 3.44 62 (16.7) 29.97 26.60 2.08 28.23 25.77 2.28 26.65 25.40 2.51 25.81 25.81 2.78 24.16 24.15 3.09 22.68 22.68 3.44 57 (13.9) 29.84 29.84 2.08 28.35 28.35 2.28 126SAN0360OW 27.09 Outdoor 27.09 2.52 25.78 25.78 2.78 24.14 24.14 3.09 22.41 22.41 3.43 72 (22.2) 40.80 19.67 2.33 38.77 19.12 2.58 36.76 18.39 2.85 34.74 17.49 3.15 32.37 16.64 3.51 29.86 15.74 3.92 67 (19.4) 37.10 24.07 2.34 35.57 23.40 2.60 33.72 22.64 2.87 31.71 21.81 3.17 29.58 20.95 3.52 27.26 20.02 3.93 1050 63 (17.2)tt 34.33 23.13 2.35 32.75 22.59 2.60 31.24 21.87 2.87 29.40 20.96 3.17 27.47 20.13 3.52 25.29 19.19 3.93 62 (16.7) 33.82 28.48 2.35 32.19 27.68 2.60 30.66 26.86 2.87 28.91 26.07 3.17 28.63 23.07 3.52 25.57 25.57 3.92 57 (13.9) 32.88 32.88 2.35 31.55 31.55 2.61 30.35 30.35 2.88 28.92 28.92 3.17 27.25 27.25 3.53 25.50 25.50 3.93 72 (22.2) 41.48 20.31 2.39 39.51 19.64 2.64 37.41 18.87 2.91 35.21 18.07 3.21 32.86 17.37 3.56 30.11 16.28 3.97 67 (19.4) 37.78 25.05 2.40 36.05 24.38 2.65 34.20 23.63 2.92 32.17 22.81 3.22 29.88 21.89 3.57 27.51 20.95 3.98 1175 63 (17.2)tt 34.97 24.09 2.40 33.30 23.54 2.66 31.58 22.78 2.93 29.84 21.98 3.23 27.79 21.02 3.58 25.55 20.05 3.98 62 (16.7) 34.41 29.88 2.41 32.71 29.09 2.66 31.07 28.26 2.93 29.81 29.80 3.23 28.13 28.13 3.58 26.15 26.15 3.99 57 (13.9) 33.88 33.88 2.41 32.53 32.53 2.66 31.25 31.25 2.93 29.73 29.73 3.23 28.06 28.06 3.58 26.12 26.12 3.99 72 (22.2) 42.22 21.12 2.47 40.15 20.42 2.72 38.02 19.64 2.99 35.69 18.80 3.29 33.09 17.90 3.64 30.36 16.98 4.05 67 (19.4) 38.45 26.31 2.48 36.67 25.70 2.73 34.71 24.96 3.00 32.51 24.04 3.30 30.29 23.17 3.65 27.74 22.17 4.06 1350 63 (17.2)tt 35.66 25.36 2.49 34.00 24.68 2.74 32.19 23.91 3.01 30.22 23.03 3.31 28.09 22.16 3.66 25.76 21.17 4.07 62 (16.7) 35.06 31.68 2.49 33.35 30.89 2.74 32.75 30.22 3.01 30.62 30.62 3.31 28.89 28.89 3.66 26.76 26.76 4.06 57 (13.9) 35.13 35.13 2.48 33.67 33.67 2.74 32.29 32.29 3.01 30.56 30.56 3.32 28.84 28.84 3.66 26.79 26.79 4.06 DETAILED COOLING CAPACITIES# CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) Capacity MBtuh Total System Total Sens# kW" 126SAN0420OW 95 (35) 105 (40.6) 115 (46.1) Capacity MBtuh Total System Total Sens# kW** 125 (51.7) CFM EWB Capacity MBtuh Total System kW+ Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Total Sens# Total Outdoor Sens# Total Sens# Total Sens# 72 (22.2) 54.36 27.88 3.35 51.35 26.59 3.66 49.38 25.80 4.04 46.63 24.67 4.45 43.51 23.47 4.92 40.21 22.23 5.43 67 (19.4) 49.18 33.77 3.33 47.11 32.66 3.65 45.00 31.71 4.02 42.37 30.53 4.43 39.68 29.35 4.90 36.67 28.01 5.42 1435 63 (17.2)tt 45.69 32.61 3.32 43.30 31.36 3.63 41.50 30.50 4.00 39.29 29.44 4.41 36.77 28.22 4.88 33.96 26.88 5.40 62 (16.7) 44.89 39.50 3.32 42.85 38.34 3.64 40.73 37.32 4.00 38.60 36.26 4.41 36.10 35.03 4.87 33.93 33.93 5.40 57 (13.9) 43.09 43.09 3.32 41.43 41.43 3.63 40.12 40.12 4.00 38.04 38.04 4.41 36.15 36.15 4.88 33.80 33.80 5.40 72 (22.2) 54.91 28.76 3.43 52.82 27.61 3.75 50.09 26.58 4.12 47.19 25.44 4.53 44.06 24.20 5.00 40.61 22.92 5.51 67 (19.4) 50.05 35.04 3.41 47.87 33.89 3.73 45.68 32.92 4.10 42.88 31.69 4.51 40.16 30.55 4.98 37.04 29.17 5.49 1600 63 (17.2)tt 46.56 33.82 3.40 44.37 32.70 3.72 41.91 31.52 4.08 39.86 30.58 4.49 36.99 29.22 4.95 34.34 27.97 5.48 62 (16.7) 45.72 41.26 3.40 43.20 39.97 3.71 41.30 39.06 4.08 39.13 37.98 4.49 37.07 37.74 4.96 34.78 34.76 5.48 57 (13.9) 44.46 44.46 3.39 42.54 42.54 3.71 40.93 40.92 4.07 39.09 39.08 4.49 37.09 37.09 4.96 34.59 34.59 5.48 72 (22.2) 56.23 29.60 3.52 53.65 28.51 3.85 50.78 27.46 4.21 47.78 26.30 4.63 44.50 25.02 5.09 40.98 23.72 5.61 67 (19.4) 51.04 36.52 3.51 48.82 35.49 3.83 46.31 34.35 4.19 43.37 33.05 4.60 40.59 31.93 5.07 37.36 30.52 5.59 1800 63 (17.2)tt 47.36 35.19 3.50 45.24 34.16 3.82 42.31 32.72 4.17 40.38 31.90 4.59 37.65 30.62 5.05 34.65 29.22 5.57 62 (16.7) 46.52 43.35 3.50 44.21 42.15 3.81 42.88 37.24 4.18 40.43 40.43 4.59 38.20 37.92 5.06 35.47 35.47 5.58 57 (13.9) 45.81 45.80 3.49 44.11 44.11 3.81 126SAN0480OW 42.01 Outdoor 42.01 4.17 40.18 40.18 4.59 38.03 38.03 5.06 35.43 35.43 5.58 72 (22.2) 56.17 27.88 3.46 53.06 26.59 3.79 51.03 25.80 4.17 48.19 24.67 4.60 44.96 23.47 5.08 41.55 22.23 5.62 67 (19.4) 50.82 33.77 3.45 48.68 32.66 3.78 46.50 31.71 4.15 43.79 30.53 4.58 41.00 29.35 5.06 37.89 28.01 5.60 1435 63 (17.2)tt 47.21 32.61 3.43 44.75 31.36 3.76 42.88 30.50 4.13 40.60 29.44 4.56 38.00 28.22 5.04 35.09 26.88 5.58 62 (16.7) 46.39 39.50 3.43 44.28 38.34 3.76 42.08 37.32 4.13 39.88 36.26 4.56 37.31 35.03 5.04 35.06 35.06 5.58 57 (13.9) 44.53 44.52 3.43 42.81 42.81 3.75 41.46 41.46 4.13 39.31 39.31 4.55 37.35 37.35 5.04 34.93 34.93 5.58 72 (22.2) 56.74 28.76 3.54 54.58 27.61 3.88 51.76 26.58 4.25 48.77 25.44 4.68 45.53 24.20 5.16 41.97 22.92 5.70 67 (19.4) 51.72 35.04 3.53 49.46 33.89 3.86 47.20 32.92 4.23 44.31 31.69 4.66 41.49 30.55 5.14 38.27 29.17 5.68 1600 63 (17.2)tt 48.11 33.82 3.52 45.85 32.70 3.84 43.31 31.52 4.21 41.18 30.58 4.64 38.23 29.22 5.12 35.48 27.97 5.66 62 (16.7) 47.25 41.26 3.51 44.64 39.97 3.84 42.68 39.06 4.21 40.43 37.98 4.64 38.31 37.74 5.12 35.94 35.92 5.67 57 (13.9) 45.94 45.94 3.51 43.96 43.96 3.83 42.29 42.29 4.21 40.39 40.39 4.64 38.32 38.32 5.13 35.75 35.74 5.66 72 (22.2) 58.10 29.60 3.64 55.44 28.51 3.98 52.47 27.46 4.35 49.38 26.30 4.78 45.99 25.02 5.26 42.34 23.72 5.80 67 (19.4) 52.74 36.52 3.63 50.45 35.49 3.96 47.85 34.35 4.33 44.82 33.05 4.75 41.94 31.93 5.24 38.60 30.52 5.78 1800 63 (17.2)tt 48.94 35.19 3.61 46.74 34.16 3.94 43.72 32.72 4.31 41.73 31.90 4.74 38.90 30.62 5.22 35.80 29.22 5.76 62 (16.7) 48.07 43.35 3.61 45.68 42.15 3.94 44.31 37.24 4.32 41.78 41.78 4.74 39.47 39.19 5.23 36.65 36.65 5.77 57 (13.9) 47.33 47.33 3.61 45.58 45.58 3.94 43.41 43.41 4.31 41.52 41.52 4.74 39.30 39.30 5.23 36.61 36.61 5.77 DETAILED COOLING CAPACITIES# CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) Capacity MBtuh Total System Total Sens# kW" 126SAN0490OW 95 (35) 105 (40.6) 115 (46.1) Capacity MBtuh Total System Total Sens# kW** 125 (51.7) CFM EWB Capacity MBtuh Total System kW+ Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Total Sens# Total Sens# Outdoor Total Sens# Total Sens# 72 (22.2) 55.67 28.40 3.17 53.33 27.55 3.48 50.86 26.68 3.85 48.24 25.75 4.26 45.42 24.79 4.74 82.31 38.78 5.38 67 (19.4) 50.38 34.86 3.17 48.24 34.01 3.48 46.00 33.13 3.83 43.61 32.20 4.25 41.04 31.21 4.72 38.24 30.13 5.25 1765 63 (17.2)tt 46.63 33.46 3.17 44.64 32.61 3.47 42.55 31.73 3.82 40.33 30.80 4.23 37.92 29.80 4.70 81.76 50.33 5.61 62 (16.7) 46.02 41.24 3.17 44.12 40.35 3.47 42.16 39.38 3.82 40.12 40.12 4.23 38.20 38.20 4.70 36.07 36.07 5.23 57 (13.9) 45.05 45.05 3.17 43.50 43.50 3.47 41.85 41.85 3.82 40.08 40.08 4.23 38.14 38.14 4.70 36.01 36.01 5.23 72 (22.2) 56.59 29.77 3.26 54.15 28.91 3.57 51.58 28.02 3.94 48.86 27.08 4.36 45.97 26.10 4.83 92.97 43.83 5.65 67 (19.4) 51.23 37.05 3.26 49.00 36.19 3.57 46.67 35.29 3.92 44.20 34.33 4.34 41.55 33.31 4.81 38.80 32.15 5.34 2000 63 (17.2)tt 47.42 35.49 3.26 45.36 34.63 3.56 43.19 33.72 3.92 40.99 32.76 4.33 38.41 31.74 4.79 80.91 50.55 5.66 62 (16.7) 47.09 44.07 3.26 45.35 42.74 3.56 43.44 43.44 3.92 41.54 41.54 4.33 39.49 39.49 4.80 37.22 37.22 5.33 57 (13.9) 46.80 46.80 3.26 45.14 45.14 3.56 43.37 43.37 3.92 41.48 41.48 4.33 39.43 39.43 4.80 37.17 37.17 5.33 72 (22.2) 57.30 31.14 3.35 54.77 30.27 3.67 52.12 29.37 4.03 49.32 28.42 4.45 46.34 27.41 4.93 43.10 26.34 5.46 67 (19.4) 51.89 39.26 3.35 49.60 38.37 3.66 47.19 37.44 4.02 44.69 36.48 4.44 41.98 35.43 4.91 39.07 34.27 5.44 2250 63 (17.2)tt 48.05 37.53 3.35 45.92 36.64 3.66 43.69 35.71 4.01 41.33 34.72 4.42 38.80 33.65 4.89 36.10 32.48 5.42 62 (16.7) 48.38 48.38 3.35 46.61 46.61 3.66 44.75 44.75 4.01 42.75 42.75 4.43 40.58 40.58 4.90 78.01 61.13 5.68 57 (13.9) 48.31 48.31 3.35 46.55 46.55 3.66 126SAN0600OW 44.69 Outdoor 44.69 4.01 42.70 42.70 4.43 40.53 40.53 4.90 38.16 38.16 5.43 72 (22.2) 68.32 33.70 4.22 65.36 32.54 4.62 62.00 31.31 5.08 58.66 30.05 5.60 54.86 28.70 6.20 50.75 27.23 6.86 67 (19.4) 62.01 41.32 4.20 59.07 40.36 4.59 56.50 38.85 5.04 53.37 37.53 5.57 49.89 36.04 6.16 46.16 34.58 6.82 1765 63 (17.2)tt 57.40 39.80 4.18 54.38 38.69 4.56 51.79 37.47 5.01 49.30 36.03 5.53 46.18 34.65 6.12 42.69 33.10 6.79 62 (16.7) 56.24 48.57 4.18 53.56 47.44 4.56 50.87 46.18 5.00 48.29 44.74 5.53 46.44 44.13 6.13 43.08 43.08 6.79 57 (13.9) 54.82 54.82 4.17 52.62 52.62 4.55 50.48 50.47 5.00 48.15 48.14 5.53 45.69 45.69 6.12 42.84 42.84 6.79 72 (22.2) 69.65 34.98 4.33 66.51 33.83 4.73 63.25 32.56 5.20 59.62 31.27 5.72 55.67 29.85 6.32 51.42 28.33 6.98 67 (19.4) 63.30 43.23 4.32 60.49 42.09 4.71 57.43 40.74 5.17 54.11 39.44 5.69 50.54 37.98 6.28 46.70 36.38 6.94 2000 63 (17.2)tt 58.59 41.65 4.30 55.93 40.46 4.69 53.04 39.11 5.14 50.00 37.76 5.65 46.77 36.36 6.25 43.18 34.79 6.91 62 (16.7) 57.56 51.23 4.30 54.86 50.08 4.68 52.11 49.07 5.13 50.02 45.77 5.66 47.28 47.28 6.26 44.25 44.25 6.92 57 (13.9) 56.82 56.82 4.29 54.73 54.73 4.68 52.25 52.25 5.13 49.52 49.52 5.65 47.12 47.12 6.25 44.23 44.23 6.92 72 (22.2) 70.90 36.21 4.46 67.56 35.02 4.86 64.07 33.76 5.32 60.32 32.38 5.85 56.25 30.97 6.44 51.83 29.40 7.10 67 (19.4) 64.31 45.21 4.44 61.36 44.04 4.84 58.18 42.68 5.29 54.74 41.32 5.82 51.04 39.82 6.41 47.05 38.25 7.07 2250 63 (17.2)tt 59.47 43.38 4.43 56.79 42.26 4.81 53.85 40.90 5.27 50.52 39.45 5.78 47.26 38.05 6.37 43.52 36.46 7.03 62 (16.7) 58.28 54.13 4.42 56.78 52.87 4.82 54.15 54.15 5.27 51.34 51.34 5.79 48.49 48.49 6.39 45.47 45.47 7.05 57 (13.9) 58.56 58.56 4.42 56.16 56.15 4.81 53.89 53.89 5.27 51.28 51.28 5.79 48.47 48.47 6.39 45.32 45.32 7.06 DETAILED COOLING CAPACITIES# CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) Capacity MBtuh Total System Total Sens# kW" 126SAN061 95 (35) 105 (40.6) 115 (46.1) Capacity MBtuh Total System Total Sens# kW** 125 (51.7) CFM EWB Capacity MBtuh Total System kW+ Capacity MBtuh Total System kW** With CVPVA6124XMC* Capacity MBtuh Total System kW** Capacity MBtuh Total System kW** Total Sens# Total OOW Outdoor Sens# Section Total Indoor Sens# Section Total Sens# 72 (22.2) 67.32 34.67 3.83 64.20 33.48 4.22 60.99 32.28 4.66 57.90 31.00 5.15 54.34 29.68 5.72 50.64 28.27 6.35 67 (19.4) 60.90 42.50 3.80 58.64 41.14 4.19 55.50 40.08 4.62 52.42 38.75 5.12 49.21 37.39 5.68 45.62 35.84 6.32 1800 63 (17.2)tt 56.36 40.94 3.78 54.06 39.62 4.17 51.28 38.52 4.59 48.35 37.20 5.09 45.29 35.88 5.65 42.13 34.30 6.28 62 (16.7) 55.24 50.04 3.78 52.84 48.82 4.16 50.32 47.80 4.59 47.69 46.92 5.08 45.54 45.54 5.65 42.78 42.78 6.29 57 (13.9) 54.18 54.18 3.78 52.35 52.35 4.16 50.05 50.05 4.59 47.86 47.86 5.08 45.41 45.41 5.65 42.67 42.67 6.29 72 (22.2) 68.30 35.79 3.93 65.12 34.59 4.31 61.99 33.35 4.75 58.61 32.05 5.25 55.02 30.70 5.82 51.12 29.27 6.45 67 (19.4) 61.98 44.30 3.90 59.29 43.17 4.28 56.24 41.80 4.72 53.07 40.45 5.21 49.71 39.07 5.77 46.11 37.51 6.41 2000 63 (17.2)tt 57.27 42.55 3.88 54.74 41.37 4.26 51.98 40.09 4.69 48.88 38.72 5.18 45.89 37.29 5.74 42.54 35.82 6.37 62 (16.7) 56.17 52.45 3.88 53.64 51.38 4.25 51.47 51.12 4.69 49.23 49.23 5.19 46.64 46.64 5.76 43.88 43.88 6.39 57 (13.9) 55.82 55.82 3.88 53.85 53.85 4.26 51.55 51.55 4.69 49.18 49.18 5.19 46.61 46.61 5.75 43.03 43.03 6.38 72 (22.2) 69.32 37.07 4.05 66.00 35.83 4.43 62.79 34.57 4.87 59.31 33.25 5.37 55.63 31.88 5.94 51.58 30.40 6.57 67 (19.4) 62.95 46.32 4.02 60.02 45.07 4.40 56.97 43.78 4.84 53.68 42.40 5.33 50.22 40.98 5.90 46.52 39.45 6.53 2250 63 (17.2)tt 58.15 44.42 4.00 55.51 43.23 4.38 52.64 41.90 4.81 49.61 40.53 5.30 46.39 39.10 5.86 42.91 37.53 6.49 62 (16.7) 57.14 55.48 3.99 56.05 55.64 4.38 53.03 53.03 4.81 50.69 50.69 5.31 47.85 47.85 5.88 44.94 44.94 6.52 57 (13.9) 57.55 57.55 4.00 55.45 55.45 4.38 53.13 53.13 4.81 50.50 50.50 5.31 47.86 47.86 5.88 44.77 44.77 6.52 t Total and sensible capacities are net capacities based on 25 feet line set at DOE Appendix Ml test levels. t Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air per degree above 80 °F (27°C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation perAHRI standard 210/240-2023. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. rr System kW is total of indoor and outdoor unit kilowatts. tt At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB - Entering Wet Bulb 126S: Product Data Condenser Only Ratings SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55.0 (12.8) 65.0 (18.3) 1 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) :0O 30.0 TCG 15.24 14.30 13.41 12.55 11.69 10.81 9.87 SDT 67.45 76.93 86.47 96.03 105.60 115.15 124.72 KW 0.76 0.88 1.00 1.14 1.29 1.46 1.66 35.0 TCG 16.81 15.81 14.87 13.94 13.00 12.03 11.02 SDT 68.44 77.89 87.39 96.91 106.44 115.99 125.45 (1.7) KW 0.75 0.87 0.99 1.13 1.29 1.46 1.66 40.0 TCG 18.52 17.46 16.44 15.44 14.42 13.36 12.26 SDT 69.49 78.90 88.37 97.85 107.33 116.85 126.25 (4.4) KW 0.75 0.86 0.99 1.13 1.28 1.46 1.66 45.0 TCG 20.36 19.24 18.15 17.07 15.95 14.81 13.60 SDT 70.65 79.98 89.40 98.84 108.35 117.74 127.16 (7.2) KW 0.74 0.85 0.98 1.12 1.28 1.46 1.66 50.0 TCG 22.36 21.17 20.00 18.83 17.62 16.38 15.07 SDT 71.84 81.13 90.49 99.89 109.37 118.73 128.05 (10.0) KW 0.73 0.85 0.97 1.11 1.28 1.46 1.66 55.0 TCG 24.53 23.24 22.00 20.73 19.42 18.07 16.64 SDT 73.10 82.46 91.69 101.10 110.44 119.75 129.07 KW 0.72 0.84 0.96 1.11 1.27 1.45 1.66 40O 30.0 TCG 20.50 19.35 18.23 17.10 15.95 14.76 13.48 SDT 68.26 77.72 87.21 96.70 106.23 115.73 125.24 KW 1.06 1.18 1.32 1.47 1.65 1.86 2.10 35.0 TCG 22.57 21.33 20.11 18.89 17.64 16.38 15.02 SDT 69.29 78.72 88.17 97.62 107.10 116.42 125.96 (1.7) KW 1.04 1.17 1.31 1.47 1.65 1.86 2.11 40.0 TCG 24.77 23.45 22.13 20.80 19.45 18.05 16.63 SDT 70.46 79.76 89.16 98.57 108.00 117.40 126.66 (4.4) KW 1.03 1.16 1.31 1.47 1.66 1.87 2.11 45.0 TCG 27.14 25.71 24.28 22.84 21.35 19.86 18.30 SDT 71.55 80.84 90.20 99.56 109.07 118.31 127.60 (7.2) KW 1.00 1.14 1.30 1.47 1.66 1.88 2.12 50.0 TCG 29.66 28.11 26.57 24.99 23.40 21.78 20.09 SDT 72.74 81.96 91.27 100.69 110.06 119.25 128.49 (10.0) KW 0.97 1.12 1.29 1.47 1.66 1.88 2.13 55.0 TCG 32.33 30.65 28.99 27.30 25.57 23.81 21.98 SDT 73.95 83.22 92.43 101.76 111.08 120.23 129.40 (12.8) KW 0.93 1.10 1.27 1.46 1.66 1.89 2.14 00O 30.0 TCG 25.87 24.58 23.14 21.61 20.02 18.41 16.75 SDT 70.63 80.16 89.60 98.97 108.29 117.58 126.79 KW 1.15 1.35 1.55 1.75 1.96 2.19 2.46 35.0 TCG 28.58 27.14 25.55 23.86 22.15 20.44 18.68 SDT 71.99 81.41 90.78 100.21 109.36 118.45 127.76 (1.7) KW 1.16 1.36 1.56 1.76 1.97 2.21 2.49 40.0 TCG 31.45 29.85 28.11 26.29 24.41 22.55 20.67 SDT 73.39 82.70 92.06 101.34 110.58 119.66 128.79 (4.4) KW 1.17 1.37 1.57 1.77 1.99 2.23 2.52 45.0 TCG 34.50 32.73 30.84 28.87 26.85 24.83 22.80 SDT 74.83 84.13 93.32 102.52 111.71 120.78 129.93 (7.2) KW 1.19 1.39 1.58 1.78 2.01 2.25 2.55 50.0 TCG 37.72 35.77 33.72 31.60 29.43 27.25 25.07 SDT 76.28 85.55 94.71 103.79 112.90 121.93 131.01 (10.0) KW 1.20 1.40 1.60 1.80 2.03 2.28 2.58 55.0 TCG 41.09 38.97 36.75 34.46 32.14 29.80 27.47 SDT 77.77 87.02 96.14 105.18 114.14 123.18 132.12 KW 1.22 1.42 1.61 1.82 2.05 2.31 2.61 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 126S: Product Data Condenser Only Ratings (Continued) SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55.0 (12.8) 65.0 (18.3) 1 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) .0O 30.0 TCG 29.51 27.83 26.26 24.71 23.13 21.48 19.72 SDT 68.00 77.50 86.97 96.46 105.99 115.44 124.84 KW 1.28 1.59 1.87 2.12 2.38 2.65 2.96 35.0 TCG 32.53 30.73 29.02 27.33 25.60 23.82 21.97 SDT 69.08 78.52 87.98 97.41 106.85 116.13 125.19 (1.7) KW 1.29 1.60 1.88 2.13 2.39 2.67 2.97 40.0 TCG 35.75 33.84 31.98 30.13 28.22 26.24 24.14 SDT 70.32 79.61 89.00 98.42 107.83 117.10 126.38 (4.4) KW 1.31 1.61 1.88 2.14 2.40 2.68 3.01 45.0 TCG 39.23 37.17 35.15 33.12 31.04 28.87 26.55 SDT 71.49 80.75 90.09 99.44 108.75 118.00 127.28 (7.2) KW 1.32 1.61 1.88 2.13 2.40 2.69 3.02 50.0 TCG 42.95 40.71 38.53 36.28 34.00 31.66 29.13 SDT 72.76 82.03 91.21 100.64 109.89 118.74 128.03 (10.0) KW 1.33 1.61 1.87 2.13 2.40 2.68 3.02 55.0 TCG 46.92 44.49 42.10 39.67 37.17 34.58 31.83 SDT 74.03 83.29 92.50 101.77 110.97 119.96 129.03 KW 1.33 1.61 2.12 2.38 2.68 3.02 1.86 0- 0O 30.0 TCG 40.38 38.28 36.23 34.16 31.99 29.73 27.24 SDT 69.06 78.37 87.73 97.09 106.44 115.76 125.05 KW 2.13 2.38 2.65 2.96 3.32 3.72 4.17 35.0 TCG 44.47 42.19 39.96 37.69 35.34 32.88 30.23 SDT 70.37 79.61 88.90 98.20 107.48 116.73 125.97 (1.7) KW 2.15 2.39 2.66 2.98 3.33 3.74 4.20 40.0 TCG 48.89 46.41 43.97 41.49 38.93 36.25 33.38 SDT 71.77 80.94 90.15 99.39 108.60 117.78 126.97 (4.4) KW 216 2.40 2.68 2.99 3.35 3.76 4.22 45.0 TCG 53.64 50.94 48.27 45.57 42.77 39.83 36.72 SDT 73.28 82.37 91.51 100.66 109.81 118.92 128.03 (7.2) KW 2.17 2.42 2.69 3.01 3.37 3.78 4.25 50.0 TCG 58.72 55.78 52.88 49.91 46.86 43.66 40.28 SDT 74.91 83.91 92.97 102.05 111.11 120.12 129.14 (10.0) KW 2.19 2.43 2.71 3.03 3.40 3.81 4.27 55.0 TCG 64.15 60.95 57.77 54.54 51.20 47.72 44.01 SDT 76.66 85.58 94.55 103.53 112.49 121.41 130.32 KW 2.20 2.45 2.73 3.05 3.42 3.83 4.30 0O 30.0 TCG 41.73 39.56 37.44 35.30 33.06 30.72 28.03 SDT 69.10 78.41 87.76 97.12 106.47 115.79 125.05 KW 2.22 2.47 2.76 3.08 3.45 3.87 4.33 35.0 TCG 45.96 43.60 41.29 38.95 36.52 33.97 31.24 SDT 70.40 79.64 88.93 98.23 107.52 116.76 126.00 (1.7) KW 2.23 2.48 2.77 3.10 3.47 3.89 4.36 40.0 TCG 50.52 47.96 45.43 42.88 40.23 37.46 34.49 SDT 71.81 80.98 90.19 99.43 108.64 117.82 127.00 (4.4) KW 2.24 2.50 2.78 3.11 3.48 3.91 4.39 45.0 TCG 55.43 52.64 49.88 47.09 44.20 41.16 37.95 SDT 73.33 82.41 91.55 100.70 109.85 118.96 128.06 (7.2) KW 2.26 2.51 2.80 3.13 3.51 3.93 4.41 50.0 TCG 60.68 57.65 54.64 51.58 48.42 45.11 41.62 SDT 74.96 83.96 93.02 102.09 111.15 120.17 129.19 (10.0) KW 2.27 2.53 2.82 3.15 3.53 3.96 4.44 55.0 TCG 66.29 62.99 59.70 56.36 52.91 49.30 45.47 SDT 76.71 85.63 94.61 103.58 112.53 121.45 130.36 (12.8) KW 2.29 2.55 2.84 3.18 3.56 3.98 4.47 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 126S: Product Data Condenser Only Ratings (Continued) SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55.0 (12.8) 65.0 (18.3) 1 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) 04•0O 30.0 TUG 39.56 37.52 35.53 33.51 31.44 29.27 26.98 SDT 68.73 78.29 87.88 97.50 107.13 116.77 126.41 (-1.1) KW 2.06 2.26 2.50 2.80 3.14 3.54 4.00 35.0 TCG 43.54 41.34 39.17 36.98 34.72 32.39 29.90 SDT 69.91 79.42 88.98 98.55 108.17 117.72 127.34 (1.7) KW 2.06 2.26 2.51 2.81 3.16 3.56 4.03 40.0 TCG 47.86 45.46 43.11 40.73 38.27 35.74 33.06 SDT 71.21 80.65 90.16 99.61 109.25 118.76 128.31 (4.4) KW 2.06 2.27 2.52 2.82 3.18 3.59 4.05 45.0 TCG 52.52 49.93 47.37 44.78 42.11 39.36 36.46 SDT 72.56 82.00 91.43 100.90 110.41 119.87 129.36 (7.2) KW 2.06 2.27 2.53 2.83 3.19 3.61 4.08 50.0 TCG 57.56 54.75 51.96 49.10 46.26 43.27 40.12 SDT 74.05 83.40 92.80 102.31 111.64 121.05 130.48 (10.0) KW 2.06 2.27 2.53 2.85 3.21 3.63 4.11 55.0 TCG 63.00 59.96 56.92 53.86 50.72 47.47 44.07 SDT 75.66 84.93 1 94.27 103.62 112.97 122.31 131.67 (12.8) KW 2.05 2.27 1 2.54 2.86 3.23 3.65 4.13 0.00O 30.0 TCG 50.80 48.21 45.65 43.05 40.34 37.49 34.43 SDT 70.45 79.72 89.03 98.37 107.69 116.98 126.21 (-1.1) KW 2.75 3.01 3.33 3.70 4.14 4.64 5.22 35.0 TCG 55.93 53.14 50.36 47.53 44.58 41.49 38.19 SDT 71.88 81.09 90.34 99.61 108.86 118.08 127.26 (1.7) KW 2.77 3.04 3.36 3.74 4.18 4.69 5.27 40.0 TCG 61.47 58.45 55.43 52.35 49.15 45.79 42.19 SDT 73.42 82.56 91.74 100.93 110.12 119.28 128.37 (4.4) KW 2.79 3.06 3.39 3.77 4.22 4.73 5.32 45.0 TCG 67.45 64.16 60.88 57.35 54.05 50.40 46.54 SDT 75.10 84.15 93.24 102.31 111.49 120.56 129.58 (7.2) KW 2.80 3.08 3.41 3.80 4.26 4.78 5.37 50.0 TCG 73.86 70.30 66.73 62.97 59.29 55.32 51.15 SDT 76.91 85.87 94.90 103.89 112.95 121.92 130.85 (10.0) KW 2.81 3.10 3.44 3.83 4.30 4.82 5.42 55.0 TCG 80.72 76.86 72.98 68.99 64.89 60.59 56.06 SDT 78.86 87.74 96.66 105.60 114.52 123.38 132.17 KW 2.81 3.11 3.46 3.87 4.34 4.87 5.47 0. 0O 30.0 TCG 48.32 45.96 43.56 41.07 38.45 35.71 32.78 SDT 70.94 80.43 89.94 99.46 109.03 118.48 127.95 KW 2.30 2.60 2.92 3.29 3.71 4.18 4.72 35.0 TCG 53.32 50.68 48.03 45.33 42.49 39.54 36.39 SDT 72.28 81.74 91.23 100.67 110.18 119.59 129.01 (1.7) KW 2.32 2.62 2.95 3.31 3.74 4.22 4.76 40.0 TCG 58.65 55.73 52.85 49.91 46.82 43.63 40.25 SDT 73.79 83.21 92.59 101.97 111.45 120.76 130.12 (4.4) KW 2.34 2.64 2.97 3.34 3.77 4.25 4.80 45.0 TCG 64.35 61.21 58.03 54.81 51.50 48.00 44.37 SDT 75.43 84.69 94.02 103.34 112.65 122.05 131.30 (7.2) KW 2.36 2.66 3.00 3.37 3.80 4.29 4.84 50.0 TCG 70.48 67.02 63.56 60.04 56.43 52.69 48.80 SDT 77.10 86.32 95.56 104.82 114.10 123.32 132.52 (10.0) KW 2.38 2.69 3.03 3.41 3.84 4.33 4.88 55.0 TCG 76.97 73.22 69.45 65.61 61.71 57.68 53.47 SDT 79.02 88.06 97.22 106.41 115.57 124.70 133.74 (12.8) KW 2.41 2.72 3.06 3.44 3.88 4.37 4.93 KW - Outdoor Unit Kilowatts Only. SDT -Saturated Temperature Leaving Compressor (°F) SST -Saturated Temperature Entering Compressor (°F/°C) TCG -Gross Cooling Capacity (1000 Btuh) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 19 126S: Product Data GUIDE SPECIFICATIONS GENERAL System Description Outdoor -mounted, air-cooled, split -system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210/240. — Unit will be certified for capacity and efficiency, and listed in AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 470 psig. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron@ (R-410A), and special features required prior to field start-up. Unit Cabinet — Unit cabinet, including louvers, will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Fans — Condenser fan will be direct -drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Air-cooled, split -system air conditioner 126S 1-1/2 to 5 nominal tons Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed. Refrigeration Com op nents — Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of Puron (R-410A) refrigerant, and compressor oil. — Unit will be equipped with low and high pressure switches and shipped with filter drier for Puron (R-410A) refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °FPC wet bulb and °FPC dry bulb, and air entering the unit at °F/°C. — The system will have a SEER2 of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Nominal unit electrical characteristics will be v, three phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. © 2022 Carrier. All rights reserved. Edition Date: 05/22 7Catalog No: PDS126S-01 Carrier Company Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 20