Loading...
BLD2024-0557_Manufacturer_Specifications_and_Installation_Instructions_4.17.2024_11.53.27_AM_4202401Job Name: System Reference: Date: MITSUBISHI AF_ ELECTRIC �1111111111111111111111111111111111111111111111' .''Illlllllllllllllllilllllllllllllllllllll''� FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 52 dB(A) • High-pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTMI B117 Standard Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) H Ducted (High -static)) Maximum Capacity BTU/H 28,400 H 28,400 // 28,400 28,400 // 28,400 Rated Capacity BTU/H BTU/H W 28,400 // 27,900 // 27,400 27,900 // 27,400 11,600 // 11,300 H 11,000 11,900 H 12,200 4,040 // 4,000 H 3,960 4,045 // 4,050 Minimum Capacity Maximum Power Input Rated Power Input W % 2,670 // 2,755 H 2,840 2,762 H 2,854 99.0, 99.0 H 99.0, 99.0 H 99.0, 99.0 199.0, 99.0 H 99.0, 99.0 Power Factor (208V, 230V) Heating at 47°F (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) H Ducted (High -static)) Maximum Capacity BTU/H 36,000 H 36,000 H 36,000 36,000 // 36,000 Rated Capacity BTU/H BTU/H 28,600 H 28,100 // 27,600 28,100 // 27,600 18,100 H 18,300 H 18,500 117,150 H 16,200 Minimum Capacity Maximum Power Input W 3,700 H 3,900 H 4,100 3,900 H 4,100 Rated Power Input W 2,149 H 2,185 H 2,220 2,198 // 2,247 Power Factor (208V, 230V) % 99.0, 99.0 H 99.0, 99.0 H 99.0, 99.0 199.0, 99.0 H 99.0, 99.0 Heating at 17°F' (Non -Ducted // Mix (Low -static) H Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 21,000 H 21,000 H 21,000121,000 H 21,000 Rated Capacity BTU/H 18,600 // 18,200 H 17,800 118,200 H 17,800 Maximum Power Input W 2,860 H 2,910 // 2,960 12,910 H 2,960 Rated Power Input W 1,820 // 1,860 // 1,900 11,876 H 1,932 Heating at 5°F4 (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 19,800 H 19,800 H 19,800 119,800 // 19,800 Maximum Power Input W 3,100 H 3,205 H 3,310 13,205 // 3,310 Efficiency (Non -Ducted H Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) SEER2 19.0 // 17.6 H 16.2 117.6 // 16.2 EER21 10.6 H 10. 1119.6 10.1H9.6 HSPF2 (IV) 10.0 H 9.4 H 8.8 9.4 H 8.8 COP at 47°F' 3.9 // 3.75 // 3.6 3.75 // 3.6 COP at 17°F at Maximum Capacity' 2.15 H 2.11 H 2.07 2.12 H 2.08 COP at 5°F at Maximum Capacity4 1.87 H 1.81 H 1.75 11.81 H 1.75 ENERGY STAR® Certified No H No H No No H No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor - Outdoor) AWG 14 Minimum Circuit Ampacity A 22.1 Maximum Overcurrent Protection A 25 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,133 / 2,243 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 52 Sound Pressure Level, Heating2 dB(A) 56 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB220FCGMC Compressor Rated Load Amps A 12 Compressor Locked Rotor Amps A 13.7 Compressor Oil Type // Charge oz. FV50S // 23.7 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 31-11/32 [796] 41-11132 [1,0501 Package Dimensions W: In. [mm] D: In. [mm] 17-5/16 [440] H: In. [mm] 38-31/32 [990] Unit Weight Lbs.[kg] 142 [64.3] Package Weight Lbs.[kg] 174 [78.9] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.4 / 5 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 'Heating at 5°F (Indoor // Outdoor) °F 70 IDS, 60 WB // 5 DB, 4 WB `Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. `" 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according toAHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. • ' 1 I SPECIFICATIONS: Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 6.0, 13.0 Maximum Pre -Charged Piping Length Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] Indoor unit connection Maximum Number of Connected IDU 3 Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 36,000 Piping Liquid Pipe Size O.D. (Flared) In.[mm] A,B,C: 1/4 [A,B,C: 6.35] Gas Pipe Size O.D. (Flared) In.[mm] A: 1/2; B,C: 3/8 [A: 12.72: B,C: 9.52] Total Piping Length Ft. [m] 230 [70] Maximum Height Difference, ODU above IDU Ft. [m] 49 [15] Maximum Height Difference, ODU below IDU Ft. [m] 49 [15] Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends for IDU 70 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 IDS, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 IDS, 60 WB // 17 DB, 15 WB Conditions 41-leating at YF (Indoor // Outdoor) °F 70 IDS, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. " 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according toAHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Refrigeration Ball Valve -1/2" ❑ PAC-SH96SG-E ❑ BV12FFS12 Refrigeration Ball Valve -1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 ontrol Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Drain Socket Drain Socket ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-A9 M-NET Converter M-NET Converter ❑ PAC-IF01 MNT-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adaptor Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801M 24" Single Fan Stand ❑ QSMS2401M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1201M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. (Foundation Bolt M10) rsrar min, 1.FREE SPACE Unit: inch (mm) LIO 1/4'(06.35)FLARE GAS 3/8'(09.52)FLARE LIO 1/4'(06.35FLARE GAS 1/2'1012.7)FLARE 2.SERVICE SPACE o E `o E Conduit plates a Conduit connector 3-15/16° Of more SERVICE SPACE 13-25/32' ❑r more 13-25/32" or more Lock nut 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ' C EtI OS FORM# MXZ-3C30NA4 - 202311 Intertek Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.