BLD2024-0564_Manufacturer_Specifications_and_Installation_Instructions_4.26.2024_9.40.44_AM_4220783
Submittal Split System Air Conditioner A4AC4030D1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " July 2022 AM-PRO-A4AC4030D-1 B-EN Product Specifications OUTDOOR UNIT (a) (b) A4AC4030D1000A POWER CON NS. — WPH/HZ M 208/230/1/60 MIN. CIR. AMPACITY 17 MAX. OVERCURRENT PROTECTION 25 COMPRESSOR SCROLL NO. USED — NO. STAGES 1— 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 12.8 — 67.8 FACTORY INSTALLED YES/NO START COMPONENTS (e) NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN ;PROPELLER DIA. (IN.) — NO. USED 23 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 2900 NO. MOTORS — HP 1-1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL -;TYPE All Aluminum ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 21.25 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) (9) 5 LBS., 8 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h)Q) 3/4 LINE SIZE — IN. O.D. LIQ. ., 3/8 CHARGING SPECIFICATIONS SUBCOOLING 8°F DIMENSIONS H X W X D CRATED (IN.) 31.7 x 31 x 31 WEIGHT SHIPPING (LBS.) 220 NET (LBS.) 184 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. M Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. Optional authorized kits include KIT07689 for RunTru or BAYKSKT267. (0 Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). 0) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. AM-PRQ-A4AC4030D-1 B-EN About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com. C VL US LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. AM-PRQ-A4AC4030D-1 B-EN 22 Jul 2022 Supersedes AM-PRQ-A4AC4030D-1A-EN (March 2022) ©2022