Loading...
APPROVED BLD BLD2020-1000+Architectural_Plan+9.28.2020_8.54.28_AMCOVER SKEET & PROJECT I BUILDING DATA ADDRESS: 9611 FIRDALE AVE, EDMONDS, WA W20 PARCEL NO: 00449900000100 LEGAL DESCRIPTION: SEC 36 TWN 21 R 03 QTR SE - FORSHEES FIRDALE VILLAGE BLK 000 D-00 - COMB FOR TAX PURP ONLY - LOT I PLUS PTN VAC CUL-DE-SAC TGW LOTS 2-3 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN WHNFORSHEE FIRDALE VILLAGE 5 ALSO LESS TH PTN LOT 3DAF - BEG AT NE COR OF 51/2 N1/2 OF 6WI/4 6El/4 TH 501;42 29W ALG E LN OF SD 5WI/4 SE1/4 510FT TH N88;26 50W 15FT TPBTH CONT N88;26 50W 104.06FT THS12;21 54E 10830FT TH N01;33 10E 30FT TPB TGW LOT 4 PLUS ADJ PTN VAC CUL-DE-SAC LESS PTN WHN FORSHEE FIRDALE VILLAGE 5 TGW LOT 5 PLUS PTN VAC CUL-DE-SAC 4 LESS PTN PROP PLAT FORSHEES FIRDALEVILLAGE NO 5 TGW LOT 12 TGW LOT 13 4 NWLY 8FT LOT 14 TGW SELY 52FT LOT 14 BUILDING: TYPE V-A OCCUPANCY: M / A-2 ZONING: FVMU 15T FLOOR: 6,406 SgFt 2ND FLOOR: 2,190 SgFt BASEMENT: 2,190 SgFt TOTAL SF.: 15,606 SgFt LOT: 3.12 Acres YEAR BUILT: 1942 SEE THIS SHEET 4 PLANS FOR ADDITIONAL CODE ANALYSIS Approved by Fire 10/13/2020 AFM fCFI tterer Fire Comments 1.Fire alarm is required to be retrofitted throughout building 2.Fire alarm panel or annunciator required to be within 10 feet of an outside door and key box entry supplied. 3.Type 1 hood is required to be integrated into the fire alarm 4.Exit signs, fire extinguishers and emergency lighting at final AREA OF WORK: UNIT 9631 UNITS 9619 4 9631 NOT THIS SUBMITTAL 2ND FLOOR AREA OF WORK: UNIT 9623: NOT THIS WDMITT>L IST FLOOR AREA OF WORK: UNITS %23 4 9623: NOT THIS SUBMITTAL BASEMENT UNIT KEY PLAN NTS 1-STORY NORTH WING TRUE NORTH PROJECT NORTH ® I -STORY SOUTH WING DESCRIPTION OF DAMAGE /SCOPE (SCOPE OF WOPoC APPLICABLE TO THIS PLAN SET 15 CLOUDED) I. FIRE DAMAGE AS FOLLOWS: a. UNIT 9623 (COLONIAL PANTRY) L ALL INTERIOR FINISHES 4 FIXTURES, INCLUDING KITCHEN EQUIPMENT 4 DINING/RECEPTION ii. ALL INTERIOR FINISHES 4 FIXTURES FOR BASEMENT OFFICE b. UNIT 9625 (SOUND PARTNERS REAL ESTATE) - ABOVE KITCHEN i. ALL INTERIOR FINISHES 4 FIXTURES c. UNIT 9623 (BROWER SALON) - BELOW KITCHEN i. ALL CEILINGS rd.UNIT631 (RAINBOW SPA) LATED CEILING 4 WALL FINISHES OKE/ODOR e. i. SMOKE/ODOR ONLY f. ROOF FRAMING 4 SHEATHING • UNIT %23 KITCHEN HOOD EXHAUST DUCT ATTIC/ROOF PENETRATION g. ROOFING AROUND DUCT ATTIC/ROOF PENETRATION 2. REPAIR SCOPE AS FOLLOWS: a. UNIT 9623 (COLONIA PANTRY) I. (N) INTERIOR FINISHES 4 FIXTURES ii. (N) KITCHEN EQUIPMENT (BY RESTAURANT DESIGNER SEPARATE SUBMITTAL) iii. (N) DINING/RECEPTION (BY RESTAURANT DESIGNER SEPARATE SUBMITTAL) b. UNIT 9625 (SOUND PARTNERS REAL ESTATE) - ABOVE KITCHEN I. (N) INTERIOR FINISHES 4 FIXTURES ii. (N) UNIT 9623 KITCHEN HOOD EXHAUST DUCT CHASE THROUGH UNIT TO ATTIC ABOVE c. UNIT 9623 (BRONZER SALON) - BELOW KITCHEN I. ALL (N) CEILINGS ii. SMOKE SEAL 4 PAINT AS REQUIRED d. UNIT 9631 (RAINBOW SPA) i. (N) CEILING 4 WALL FINISHES AS REQUIRED ii. SMOKE SEAL 4 PAINT AS REQUIRED e. UNIT 9619 (VACANT) L SMOKE SEAL 4 PAINT - NO PERMIT REQUIRED PER CITY f. (N) ROOF STRUCTURE • UNIT 9623 HOOD DUCT g. ALL (N) ROOFING N ABBREVIATIONS O AB(s) ANCHOR BOLT(s) FT FOOT, FEET PNL PANEL N ADEQ ADEQUATE FTG FOOTING PT POINT 00 ADD'L ADDITIONAL GA GAUGE PWD PLYWOOD N ALUM ALUMINUM GALV GALVANIZED REINF REINFORCEMENT °' BLDG BUILDING GCB GYPSUM CEILING BOARD RQD REQUIRED BLKG BLOCKING GLB GLULAM BEAM SI SQUARE INCHES _o BM BEAM GWB GYPSUM WALL BOARD SC SOLID CORE 0- BOT BOTTOM HC HOLLOW CORE SHT SHEET BRG BEARING HD(s) HOLDOWN(s) SHTG SHEATHING BTWN BETWEEN HDR(s) HEADER(s) SIM SIMILAR U 't CENTER LINE HDWR HARDWARE 5OG SLAB ON GRADE o CTR(d) CENTER, CENTERED HF HEM FIR SPCG SPACING O CLG CEILING HORIZ HORIZONTAL $Q SQUARE _w CLR CLEAR IBC INTERNATIONAL BUILDING CODE SgFt SQUARE FEET Z COL COLUMN I/F INSIDE FACE STRUCT STRUCTURAL V) COMP COMPOSITION, COMPOSITE INSUL INSULATION SW SHEAR WELL Z CONIC CONCRETE INT INTERIOR T4G TOUNGE 4 GROOVE a CONT CONTINUOUS IRC INTERNATIONAL RESIDENTIAL CODE TYP TYPICAL o CONTR CONTRACTOR JT JOINT UNO UNLESS NOTED OTHERWISE o CTV CONTRACTOR TO VERIFY LAM(s) LAMINATION(s) VERT VERTICAL V) DEMO DEMOLISH, DEMOLITION Ibs POUNDS W/ WITH J DF DOUGLAR FIR MAX MAXIMUM W/0 WITHOUT 0- DIA, ll� DIAMETER MFR MANUFACTURER WIN WINDOW o DIST DISTANCE MIN MINIMUM WSEC WASHINGTON STATE ENERGY CODE N DTL DETAIL (N) NEW XFR TRANSFER (E) EXISTING NOM NOMINAL o o EA EACH O.C. ON CENTER EQ EQUAL O/F OUTSIDE FACE g ES EA SIDE OSB ORIENTED STRAND BOARD EW EACH WAY OH OVERHANG X EXT EXTERIOR PE PRE ENGINEERED FF FLUSHED FRAMED, FINISHED FLOOR fe PLATE E O FLR FLOOR PLCS PLACES FND FOUNDATION P-NAILS PNEUMATIC NAILS Lr_ LEGEND • ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work FIRE DAMAGE Address 9617 FIRDALE AVE # 9631 ----------------------------------------- ---------------------------------------- Owner FIRDALE VILLAGE ------------------------------------ Approved Date 12-2-2020 Building Official Erg Permit Number BLD2020-1000 3. CODE UPGRADES AS FOLLOWS (NOT INCLUSIVE): a. (N) SOLID ROOF SHEATHING OVER (E) ROOF BOARDS b. (N) COLLAR TIES FOR RAFTERS c. ALTERATIONS TO (E) CRIPPLE WALLS BELOW RAFTERS d. ALTERATIONS TO (E) 2ND FLOOR FRAMING • UNIT 9623 HOOD DUCT e. FIRE -RATED CONSTRUCTION i. 2-HR SEPARATION AT UNIT %23 ii. 2-HR HOOD DUCT CHASE (CEILING TO ROOF) iii. 1-HR RATED CEILINGS UNITS 9625 4 9623 SEE PLANS FOR ADD'L INFO ARCHITECTURAL/STRUCTURAL REPAIRS PROVIDE (N) INTERIOR 4 EXTERIOR ARCHITECTURAL 4 STRUCTURAL CONSTRUCTION AS NOTED PER THE PLANS. ALL (N) CONSTRUCTION SHALL COMPLY WITH THE 2015 IBC AS AMENDED 4 ADOPTED BY THE LOCAL JURISDICTION. ELECTRICAL, MECHANICAL, 4 PLUMBING: PROVIDE (N) ELECTRICAL, MECHANICAL, 4 PLUMBING FIXTURES 4 SERVICES WITHIN THE DAMAGED AREAS AND AS OTHERWISE NOTED PER THE PLANS. ALL (N) CONSTRUCTION WILL BE BACK TO THE (E) ROUGH -INS. PLAN TITLE Wl = SW DESIGNATION PER SCALE: 1'=10'-0' PLAN TITLE UNDERLINE WI SW TABLE ON SID QI I = REVISION NUMBER a NORTH ARROW 0 INDICATES AREA WITH A REVISION A DETAIL TITLE DETAIL/SECTION TITLE UNDERLINE SMOKE DETECTOR SXX SCALE: 1'=1'-0' SXX =SHEET WHERE DETAIL/SECTION 5D No New E a EXIST IS DRAWN N 8CMCARBON MONOXIDE ALARM 1 = DETAIL NUMBER N N= NEW E =EXIST 1 SX,X = REFERENCE WHERE DETAIL SX X IS TAKEN ON EXHAUST FAN 50cfm BATH No NEW E a EXIST 100cfm KITCHEN 1 = SECTION NUMBER gnu HOT WATER HEATER 1 SX.X = REFERENCE WHERE SECTION SXx IS TAKEN N No NEW E =EXIST EXISTING WALLS TO REMAIN 1 1 = ELEVATION NUMBER SXX SX.X = REFERENCE WHERE ELEVATION EXISTING WALLS TO BE REMOVED IS TAKEN QQ DOOR MARK PER SCHEDULE NEW 2x4/2x6 WALLS/SHEAR WALLS < WINDOW MARK PER SCHEDULE p DEDICATED EXHAUST ROOF VENTS APPROVED PLANS MUST BE ON JOB SITE CODES USE FOR TNIS PROJECT: 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 INTERNATIONAL BUILDING CODE 2015 WASHINGTON STATE ENERGY CODE ;;AS AMENDED 4 ADOPTED BY THE CITY OF EDMONDS STATEMENT OF USE 4 LIABILITY THESE PLANS ARE FOR THE EXCLUSIVE USE OF STATEWIDE RESTORATION BCIE ASSUMES NO RESPONSIBILITY OR LIABILITY FOR USE OF THESE PLANS BY OTHERS. ALL INFORMATION ON THESE PLANS IS THE EXCLUSIVE PROPERTY OF BCIE AND DOES NOT EXPRESS NOR IMPLY ANY WARRANTY OF THE INFORMATION ON THESE PLANS. BUILDING DESIGN NOTES ARCHITECTURAL THE CONTRACTOR AND SUBCONTRACTORS PERFORMING THE ARCHITECTURAL WORK, WHICH INCLUDES: EXTERIOR AND INTERIOR FINISHES, EXTERIOR FLASHING 4 CAULKING, INTERIOR FLOORING, TRIM, ETC. DAMAGED BY THE FIRE (SMOKE OR MEAT) SHALL REMOVE AND REPLACE THE ARCHITECTURAL ITEMS TO MATCH ORIGINAL CONDITIONS. THE ARCHITECTURAL WORK SHALL BE PER THE 2015 IRC AS AMMENDED 4 ADOPTED BY CITY OF EDMONDS AND THE STATE OF WASHINGTON. ELECTRICAL, MECHANICAL, 4 PLUMBING: THE CONTRACTOR AND SUBCONTRACTORS PERFORMING THE ELECTRICAL, MECHANICAL, 4 PLUMBING WORK SHALL INSTALL NEW ITEMS TO MATCH THE ORIGINAL ITEMS. SEPARATE PERMITS FOR ELECTRICAL AND MECHANICAL SHALL BE SUBMITTED TO CITY OF EDMONDS BY THE ELECTRICAL AND MECHANICAL CONTRACTORS. THE ELECTRICAL 4 MECHANICAL CONTRACTORS ARE RESPONSIBLE FOR SPECIFICATIONS OF ELECTRICAL SERVICES (AS REQ'D), MECHANICAL EQUIPMENT (AS REM)), 4 PLUMBING FIXTURES (AS REQ'D). ALL WORK SHALL COMPLY WITH CURRENT ELECTRICAL, MECHANICAL, AND PLUMBING CODES AS AMMENDED 4 ADOPTED BY CITY OF EDMONDS AND THE STATE OF WASHINGTON. PROJECT TEAM CONTRACTOR: STATEWIDE RESTORATION CONTRACTORS LICENSE" 5TATERI866KH CONTACT: NICK YERMALAYOV 4253461o504 (C) SHEET INDEX INVESTIGATIVE/RESTORATION ENGINEER BC INVESTIGATIVE ENGINEERS CONTACT: JE55E BINFORD, PE PRINCIPAL 2531010.9513 GENERAL CS COVER SHEET ARCHITECTURAL: A1.0 DESIGN NOTES A2.0 BASEMENT 4 2ND FLOOR REFLECTED ALI PARITAL BASEMENT 4 IST FLOOR PLAN CEILING PLAN All PARTIAL 2ND FLOOR 4 ATTIC FLOOR PLAN A2.1 SUSPENDED CEILING DETAIL A13 ROOF DRAINAGE 4 VENTILATION PLAN A3,0 BUILDING SECTION (I OF 2) AIA ADA RESTROOM LAYOUT 4 DETAILS A3.1 BUILDING SECTION (2 OF 2) A3.2 FIRE -RATED DETAILS II TOTAL SHEETS, THIS SET VICINITY MAP Rormer WoodwayQ Scriber Lake High Schaal Hlgh School 3 Hlk Madrona K:B Sehool0 ekittartPar� _ ` Ballinger . nnrasw Play}ield vPRC Edmonds(Formerly Ballinger f^= Local Roels Marijuana) ARCABE EDiTMN `s p Lake Park ' Edmonds Castle < xxrm,v�sw .34„i k. M1v o O z _ Neil,..=.:.w .Boel Ramp Al f f Salew:ry® Lake Bal6 ngery �xa"yaw n, PFamSy Pancake House Nile Shrine Golf Cr r'v 1 x 73fiN sl sw ii Sim In the Sky F lsland IN w _J o gi s s FIRDALE VILLAGE /^,� s f f [Jenny's n Rego r :Abu el SM �Tla TrindS Pantry yL;;�� ri-nlnr.i Ll"I: anes ¢P Bread !� 74411, 51 SW Q s ® RlC:IO j �I��II _ Kruckeherg � vw � "sr - � � n?uai, sr 3 _ a } ®Holy.rood Calholi[Cemetery ataniC Garden { nw onion : S3 wioro Gli4l ® vCa5lcp wholesale i - i C081c. CaSaillie� h,moro 70011, SI H I L L W 0 0 D '-�- Camrnons D Melvin G Syre v _ f row �qe�l, s: Aparlme.pl Ho-7 Elementary School 5. __ Gnngregal noel O le Go — CITY OF EDMONDS DEVELOPMENT SERVICES • • DESIGN NOTES (APPLICABLE ONLY i0 ACTUAL U1O5C BEING DONE) GENERAL FLOOR PLAN NOTES ENERGY CODE/BUILDING ENVELOPE- GENERAL I. TENANT SPACES HEATED W/ ELECTRIC WALL HEATERS. 2. ALL WINDOWS 4 DOORS SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO MINIMIZE AIR LEAKAGE. 3. ALL VAPOR BARRIERS SHALL BE A MAXIMUM OF I PERM. 4. BUILDING ASSEMBLIES USED AS DUCTS OR PLENUM SHALL BE SEALED, CAULKED AND GASKETED t0 LIMIT AIR LEAKAGE. ELECTRICAL- GENERAL I. BUILDING SHALL BE WIRED WITH NMB 90 NONMETALLIC SHEATHED CABLE (COMPLIES w/J5 STANDARDS: NM52C14US-14/2 WIREt NM52C12US- 12/2 WIREt NM53C14U5- 14/3 WIRE). 2. (E) SERVICE ENTRANCE ABOVE GROUND (ASSUMED). ELECTRICAL LIGHTING I. LIGHTING CONTROLS SHALL BE PROVIDED FOR EACH SEPARATE AREA, READILY ACCESSIBLE At THE POINT OF ENTRY/EXIT. CONTROLS SHALL BE CAPABLE OF TURNING OFF ALL LIGHTS WITHIN THE SPACE. 2. MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR CONTROL SHALL NOT EXCEED A 15 AMPERE CIRCUIT LOADED TO 8090 CAPACITY. MECHANICAL SYSTEM- GENERAL 1. THER 05TAT SHALL BE RATED FOR INTERIOR OR EXTERIOR WALL INSTALLATION. NOT APPLICABLE FOR ELECTRIC HEAT 2. SEAL ALL TRANSVERSE DUCT JOINTS. 3. SUPPLY AIR DIFFUSERS SHALL BE PROVIDED WITH MANUAL DAMPERS FOR BALANCING THE SYSTEM. 4. DUCTS SHALL BE SEALED IN ACCORDANCE WITH SMACNA- METAL DUCT AND FLEXIBLE CONSTRUCTION STANDARDS 15T ADDITION, 5. DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED t0 THE BUILDING INSPECTOR AND OWNER PRIOR t0 AN APPROVED FINAL INSPECTION. (WSEC C402.5.1.2) 6. BUILDING AIR LEAKAGE TESTING, DEMONSTRATING THE SPECIFIC AIR LEAKAGE RATE OF THE BUILDING ENVELOPE SHALL NOT EXCEED 0.40 CFM/FT2 At A PRESSURE DIFFERENTIAL OF 03 INCHES WATER GAUGE (2.0 L/S X M2 AT 15 PA) AT THE UPPER 95 PERCENT CONFIDENCE INTERVAL IN ACCORDANCE WITH ASTM E 119 OR AN EQUIVALENT METHOD APPROVED BY THE CODE OFFICIAL, (WSEC C402.5.1.2), IS REQUIRED PRIOR TO FINAL INSPECTION. 1. A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED t0 THE BUILDING INSPECTOR PRIOR t0 AN APPROVED FINAL INSPECTION. (WSEC C402.5.12) PLUMBING- GENERAL 1. ALL PLUMBING TO BE IN ACCORDANCE WITH THE AMENDED 2015 PLUMBING CODE. 2. ALL FITTINGS t0 BE BOWPEX (BRASS/BARB) T5, ELBOWS, AND COUPLINGS. 3. ALL DRAINAGE PIPE t0 BE ABS SCHEDULE 40. 4. ALL WATER PIPE TO BE PEX POTABLE TUBING (ULC LISTED). PERFORMANCE STANDARDS PER ASTM F816/F811. 5. ALL PIPES TO BE SECURED USING APT TUBE CLAMPS. ABS TO BE BLOCKED 4 STRAPPED. 6. ALL SINKS SHALL BE EQUIPPED WITH CLEAN -OUT. 1. ALL WATER PIPES OUTSIDE OF CONDITIONED SPACE SHALL BE INSULATED AND EQUIPPED WITH HEAT TRACE TAPE. 8. MIN R-10 INSULATION UNDER WATER HEATER SHALL BE MET BY THE R-34 BATT INSULATION LOCATED IN THE FLOOR 9. THE HOT WATER TANK SHALL COMPLY WITH STANDARD: ANSI Z21.10.1-1998. FLOOR PLAN NOTES (APPLICABLE ONLY TO ACTUAL WORK BEING DONE) (N) VINYL WINDOWS: SIZES AND TYPES TO MATCH EXISTING UNLESS COORDINATED OTHERWISE BETWEEN HOMEOWNER 4 CONTRACTOR (N) INTERIOR FINISH SCHEDULE: (N)1/2" GWB ALL INTERIOR WALLS w/6d COOLER NAILS 9 1/1 MINIMUM SPACING, UNO PER THE PLANS. (N)1/2" GCB ALL INTERIOR CEILINGS W/ 6d COOLER NAILS is 1/1 SPACING, LINO PER THE PLANS. USE APPROVED BACKER BOARD MATERIALS AS LISTED PER R102.42 ON THE BATH TUB 4 SHOWER WALLS. ALL OTHER FINISHES SUCH AS FLOOR AND COUNTER COVERINGS TO BE SELECTED BY THE CONTRACTOR (N) DOORS: SIZES AND TYPES TO MATCH EXISTING UNLESS COORDINATED OTHERWISE BETWEEN HOMEOWNER 4 CONTRACTOR (N) ROOF VENTING: PROVIDE VENTING PER PLANS. (N) INSULATION: PROVIDE R-15c UNFACED GATT INSULATION FOR (E) WALLS. PROVIDE R-30c FACED SATT INSULATION FOR MAIN FLOOR/BASEMENT CEILING INSULATION. PROVIDE R-49 BLOWN -IN INSULATION FOR ROOF INSULATION. WALL LEGEND a N (E) IHR RATED 2x4 EXT WALLS W/ (N) 5/8' TYPE 'X' GWB • INSIDE FACE AS NOTED PER DTLs A/A3.0 4 A/A532 Cb (A) 2x4 WALLS m (E) 2HR RATED SEPARATION WALLS W/ 2-(N) 5/8' TYPE 'X' GWB is INSIDE FACE A$ NOTED PER DTLs A/A3.1 4 C/A32. (E) IHR RATED SEPARATION WALLS W/ (N) 5/8' TYPE 'X' GWB AS NOTED PER DTLs A/A3.0, A/A3.1 4 5/A32 NOTE: HATCHED WALLS INDICATE FIRE RATED WALL WHERE GWB IS BEING REPLACED. NO HATCHING INDICATES A NON -FIRE RATED WALL -OR- A FIRE RATED WALL THAT IS NOT BEING MODIFIED CONTRACTOR NOTE: CONTRACTOR SHALL TAKE TIME t0 THOROUGHLY VERIFY ALL DIMENSIONS, HEIGHTS, STAIR RISE AND RUN, FRAMING LUMBER SIZE COMPATIBILITY, STEM WALL HEIGHTS, ROOF PITCH, OVERHANGS AND ANY OTHER CONDITION WHERE NEW CONSTRUCTION MEETS EXISTING. PRIOR TO ANY CONSTRUCTION, CONTRACTOR SHALL TAKE TIME TO LAYOUT NEW CONSTRUCTION TO VERIFY THE COMPATIBILITY BETWEEN NEW AND EXISTING CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND CONTACT BCIE IMMEDIATELY. I. GENERAL CONTRACTOR MUST VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTACT ARCHITECT IF ANY DISCREPANCIES ARE FOUND. ALL WORK SHALL BE IN COMPLIANCE WITH NFPA, OSHA, 2015 IBC, AND ALL OTHER PPLICABLE GOVERNMENT AND REGULATORY AGENCIES. 2. MAINTAIN A MINIMUM OF 36' CLEAR, UNOBSTRUCTED EMERGENCY EXIT AISLE TOWARD DESIGNATED EXIT. 3. ALL DOORWAY THRESHOLDS MUST COMPLY WITH CURRENT AND APPLICABLE CODE REQUIREMENTS. 4. ALL EXITS TO THE EXTERIOR OF THE BUILDING SHALL BE SIGNED AMC) ILLUMINATED PER IBC SECTION 1008. 5. PROVIDE A FLOOR OR LANDING ON EACH SIDE OF DOORS NOT MORE THAN 1' LOWER THAN THE THRESHOLD OF THE DOORWAY (1/2' IF BEVELED 1:2). LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR DOORS IN FULLY OPENED POSITION SHALL NOT REDUCE A REQUIRED DIMENSION BY MORE THAN 1 INCHES. (o. EXITS SHALL BE ILLUMINATED At ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT-CANDLE AT FLOOR LEVEL. 1. PROVIDE PORTABLE FIRE EXTINGUISHERS (2AI05C OR BETTER) (1) FOR EVERY 3,000 SF OF BUILDING FLOOR AREA OR 15' OF TRAVEL DISTANCE. EXTINGUISHERS AND MOUNTING BRACKETS TO BE UL LISTED. 8. ALL FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS III OR HIGHER (FLAME SPREAD INDEX 1(o THRU 200 AND A SMOKE DENSITY OF 450). 9. THE BLDG., DOORS 4 WINDOWS SHALL BE SEALED, CAULKED, OR GASKETED. 10. ELECTRICAL WORK IS DESIGN -BUILD. THE ELECTRICAL WORK, SHOWN HEREIN, IS DIAGRAMMATIC AND ILLUSTRATES THE GENERAL DESIGN INTENT, SCOPE, AND LOCATION OF THE WORK ANY WORK, NOT INDICATED HEREIN, BUT REQUIRED BY CODE, OR BY THE SPECIFICTAIONS, OR TO MAKE THE WORK COMPLETE, AND FUNCTIONING, IS TO BE PROVIDED AS PART OF THE WORK. 11. MECHANICAL WORK IS DESIGN -BUILD. THE MECHANICAL WORK, SHOWN HEREIN, IS DIAGRAMMATIC AND ILLUSTRATES THE GENERAL DESIGN INTENT, SCOPE, AND LOCATION OF THE WORK ANY WORK, NOT INDICATED HEREIN, BUT REQUIRED BY CODE, OR BY SPECIFICATIONS, OR TO MAKE THE WORK COMPLETE, AND FUNCTIONING, IS TO BE PROVIDED AS PART OF THE WORK. 12. PLUMBING WORK IS DESIGN -BUILD. THE PLUMBING WORK, SHOWN HEREIN, IS DIAGRAMMATIC AND ILLUSTRATES THE GENERAL DESIGN INTENT, SCOPE, AND LOCATION OF THE WORK. ANY WORK, NOT INDICATED HEREIN, BUT REQUIRED BY CODE, OR BY THE OF THE WORK. ANY WORK, NOT INDICATED HEREIN, BUT REQUIRED BY CODE, OR BY THE SPECIFICTAIONS, OR t0 MAKE THE WORK COMPLETE, AND FUNCTIONING, IS t0 BE PROVIDED AS PART SPECIFICTAIONS, OR TO MAKE THE WORK COMPLETE, AND FUNCTIONING, IS TO BE PROVIDED OF THE WORK 13. CONTRACTOR AND ALL SUBCONTRACTORS ARE NOT t0 SCALE ANY DRAWINGS TO IDENTIFY DIMENSIONS IF THERE ARE DIMENSIONS NOT SHOWN ON DRAWINGS CALL ARCHITECT / DESIGNER TO VERIFY THOSE DIMENSIONS. DOOR SCHEDULE MARC DOOR SIZE TYPE DOOR CONSTRUCTION JAMB CONST. HDW THICK X WIDTH X HEIGHT CORE MAIL. FINISH MAIL. FINISH REMARKS 1 3/4' x 3'-0' x V-8' - SC WD FACTORY WD PAINT 50% GLAZING, DUTCH 1 3/8' x 3'-0' x V-8' - HC MTL FACTORY MTL PAINT - 1 3/8' x 2'-8' x V-8' - HC MTL FACTORY MTL PAINT - ® 1 3/8' x 2'-0 x V-8' - HC MTL FACTORY MTL PAINT - 0 1 3/8' x 2'-4' x (0'-8' - HC MTL FACTORY MTL PAINT L- NOTES: 1. ALL EXTERIOR DOORS SHALL HAVE FULL WEATHER STRIPPING. 2. MAX. ACCEPTABLE U-VALUE + 0.4.15 FOR NON -SWINGING DOORS, TYP, ALL EXTERIOR DOORS. 3. COORDINATE FINISHES/STYLES W/ TENANT. 4. DOOR HARDWARE TO BE CHOSEN PER CONTRACTOR/OWNER. ALL HARDWARE PULLS, HANDLES, LOCKS, LATCHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST TO OPERATE PER 2015 IBC 1010.13.1. 5. ALL MOUNTED HARDWARE WITH OPERABLE PARTS SHALL BE LOCATED BETWEEN 34' AND 48' ABOVE THE FINISHED FLOOR PER 2015 IBC 1010,132. 6. ALL INTERIOR 4 EXTERIOR DOORS SHALL BE READY OPENABLE FROM THE EGRESS SIDE WITHOUT USE OF A KEY OR SPECIAL KNOWLEDGE PER 2015 IBC 1010.1.9. 1. PANIC AND FIRE EXIT HARDWARE SHALL BE PROVIDED ON ALL DOORS W/ LOCKS AND LATCHES PER 2015 IBC 1010.1.10 • • • • CITY OF EDMONDS DEVELOPMENT SERVICES (E) STAIRS TO IST FLOOR BALCONY - (E) WRAPPED COLUMNS NO WORK FOR BALCONY - NO WORK coo a E 7 js7 W 2 "o O � A3.0 � T s �b�s � �r 4¢ _4 (E) 18T FLR BALCONY a z 0 NO WORK Z N I 0 NO WORK ADJACENT NO WORK ADJACENT UNIT 0623 UNIT 9617 (E) RSTRM (E) STORAGE TENANT SPACES TENANT SPACES (N) CEILING FINISHES NO WORK NO WORK • ADJACENT (N) INTERIOR FINISHES NO WORK SMOKE SEAL 4 PAINT TENANT SPACES (N) FIXTURES • II �cx� I II 5 50cfm I I I N ADA UNISEX RSTRM 0 EF N I I I I SEE SHEET AIA FOR ACCESSIBLE Q I I I I LAYOUT INFO W II � (N) INTERIOR FINISHES q � (N) FIXTURES (E) RECEPTION E WAITING RM (E) FRONT OFFICE EF (E) STORAGE � NOcfm NCcf EF (N) INTERIOR FINISHES 0 - J 2-(N) 5/8' TPE 'X' GWB I j (E) KITCHEN I I °. • (3) SIDES OF (E) BMs lN) INTERIOR FINISHES I I (E) UNISEX RSTRM L (TYP AS NOTED = _ _ _) I SEE KITCHEN PLANS I I ~ FOR App'L INFO I 1 (N) INTERIOR FINISHES � (N) FIXTURES � II II • ~ II II 0LL E HALL IIO N (N) CEILING FINISHES 50cfm I I I I O E HALL (N) INTERIOR FINISHES (E) BTHR I I O (N) CLG FIN15HE L4~,L4 W 50cfm W (E) BACK OFFICE Q II II Q I% WMD W UP 1 I I I I IV, (N) WOOD -WRAP PER y� 1 OWNERXITCHEN DESIGNER E BRONZING A 1 s (AS NOTED l'7�1�) 1 1 0 • E FFI E 1 1 (E) DINING RM ; W O O C (N) INt 10 (N) CEILING FINISHES 1 !� 1 ER R FINISH S E M Lu r N N ao u- (N) 5/8' TPE 'X' GWB I E S A w w Q z IS (3) SIDES OF (E) BMs O � (TYP AS NOTED = _ _ _) 1 DN 1 O W A w z I A I 1%� � O v a A3.1 1 A3.1 00 �J N HW w N UNIT 9 1 UNIT 9627 Q o W 00 DOWNSTAIRS OF RESTAURANT (E) WINDOWS TO REMAIN - M--� < q llN (N) CEILING FINISHES ONLY TYP UNO U °' SMOKE SEAL 4 PAINT (E) DOORS t0 REMAIN - U ,O TYP UNO ,~T Q [� 0 • � O (E) WRAPPED COLUMNS w w FOR BALCONY - NO WORK �j Q z w � 0 o N • 1-11 W w Ld (E) STAIRS TO 2ND FLOOR BALCONY - o N NO WORK M w Z PARTIAL BASEMENT FLOOR PLAN MAIN FLOOR PLAN q 0 Z SC,4LE: 1/4' = 1'-0" (N)1-HR RATED CEILINGS PER SHEETS A3.0, A3.1 4 DTL F/A32 SCALE: 1/4" = 1'-0' � (E)1HR RATED 2x4 EXT WALLS q g SEE WALL LEGEND ON AI.O FOR BAL OF INFO 0- 0 (E) 2HR RATED SEPARATION WALLS g SEE WALL LEGEND ON AI.O FOR BAL OF INFO N (k N (N) 2-HR RATED CEILINGS PER SHEETS A3.0, A3.1 4 DTL 3/A32 N o , ' O m ~ o W X Q� R CEIV D Z CITY OF EDMONDS DEVELOPMENT SERVICES LL4. q q I C r II II II I I� II II II II II --------- -- I I II II �I II II II �I II II II �I II II II II II II ILJ I II II I I I II II II II II II II II IL I I I II II II II I j 7— J II ,I II II ,I II II II ,I II II II ,I II II I I I j i I I --7 r�====___________�---, (E) WALLS BELOW I I I , , InrJjL---- ----------------------------------------------------- IIII Ir-----------, r------------------------------------ r---- 1 0 1 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I, II II ` I L J I I I I �� I --- ------------ I I I i L-----------J I I I p Ir------------I II II II L II II II ,1J I I I I I I I I I II----------�--------------------�J 4L— I II ------AlW O (N) 2-HR FIRE CHASE -RATED FOR (N) KITCHEN HOOD EXHAUST Q ,\ / ;< (E) PULL -DOWN DUCT - SEE DTLs G/A32 4 H/A32 ` ; ; ATTIC ACCESS L_x_J O (E) STORAGE NO WORK (N) 2x4 WALL W/ (N) 5/8' TYPE 'X' GWB • ATTIC SIDE FOR (N) DRAFT STOP (E) 2x4 WALL W/ (N) 5/8' TYPE 'X' GWB • ATTIC SIDE FOR (N) DRAFT STOP (E) STORAGE NO WORK UNIT 9613 NO WORK ATTIC FLOOR PLAN SCALE: 1/4' =1' -O" (E) IHR RATED SEPARATION WALLS SEE WALL LEGEND ON AI.O FOR BAL OF INFO (N) 2x4 WALL FOR DRAFT STOP W/ (N) 5/5' TYPE 'X' GWB ATTIC SIDE (E) 2x4 WALL FOR DRAFT STOP W/ (N) 5/8' TYPE 'X' GWB 's ATTIC SIDE ONLY 0 (E) WRAPPED COLUMNS FOR — 1ST FLOOR BALCONY - NO WORK (E) STORAGE (E) MASSAGE RM3 (E) MASSAGE RM2 I (N) 2-HR FIRE -RATED CHASE - NOT PART OF THIS SUBMITTAL L (E) OFFICE3 z SMOKE SEAL 4 PAINT LLI BTHRM WAqTERIOR FINISHES (N) FIXTURES 'Q O 7 E OFF E PACE (N) INT 10AINISHE6 0000 QI 10-26-20 CITY REVIEW COMMENT (E) WINDOWS TO REMAIN - TYP UNO SEAL 8 PAINT z �v W 0 N SMOKE AL 4 PA INt 0 SMOKE SEA% PAINT Ir---1 E PL ATTIC A L_x_J (E) MASSAGE RMi N� SMOKE ��T OFF4 PAT I� O (E) DOORS TO REMAIN - (E) RECEPTION TYP UNO UNIT I UNIT oe251 I UNIT 9619 SMOKE SEAL 4 PAINT ISOLATED CEILING 4 WALL FINISH REPAIRS (CTV) (E) WRAPPED COLUMNS FOR BALCONY - NO WORK PARTIAL SCALE: 1/4' =1'-0" (E) 2ND FLR BALCONY NO WORK Z IN UPPER FLOOR PLAN (E)1HR RATED 2x4 EXT WALLS SEE WALL LEGEND ON A1.0 FOR BAL OF INFO (E)1HR RATED SEPARATION WALLS SEE WALL LEGEND ON A1.0 FOR BAL OF INFO (E) CLOSET (E) BTHRM (E) OFFICE2 (E) FRONT OFFICE (N) I-HR RATED CEILING PER SHEETS A3A A53D 4 DTL E/A32 FOR UNIT 9625 UNIT 9613 NO WORK RESUB Oct 26 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • • • • q O O W • W W q C) A I� 0 5, OUTLINE OF (E) EXT WALLS (E) LOWER ROOF NOT SHOWN FOR CLARITY (NO WORK) (N) IN -VENT COR-A-VENT 3'-0' LIP — SLOPE OF (E) EXT WALL - CTV 1' NET AIR CLEARANCE BTWN INSULATION 4 ROOF SHTG (N) 2-HR FIRE -RATED WOOD -CHASE W/ — (N) FLASHING 4 CRICKETS PER CONTR FOR (N) KITCHEN HOOD EXHAUST DUCT - SEE DTL G/A3.2 4 H/4,32 FOR BAL OF INFO (N) DIMENSIONAL COMP ROOFING - TYP LINO (N) CONT RIDGE VENT (N) CONT RIDGE VENT - CTV MIN NET — WIDTH PROVIDED • (E)/(N) ROOF SHTG - TYP LINO ROOFING 4 SHTG KEPT BACK MIN 1' EA SIDE OF RIDGE SPLINE FOR AII;�FLOW RIDGE VENT DETAIL NTS 0 i i i i L------------------------- (N) IN -VENT COR-A-VENT 1'-O' UP A SLOPE OF (E) ATTIC CRIPP L - A13 CTV 1' NET AIR CLEARA TUN INSULATION 4 ROOF (N) COR-A-VENT IN -VENT OR ? EQUIVALENT INSTALLED PER -- --------------------------------------- ,, MFR GUIDELINES 1'-0' 3'-0' • SIM COND NE OF (E) CRIPPLE WALLS__7 1' CONT AIR SLOT FOR (N) COR-A-VENT (E) CRIPPLE WALLS - (E) EXT WALLS 6 SIM IN -VENT DETAIL NTS of (E) GUTTERS 4 DOWNSPOUTS TO (E) TIGHTLINES ROOF DRAINAGE & VENTILATION PLAN NTS O z Lu (E) LOWER ROOF NOT SHOWN FOR CLARITY (NO WORK) (E)/(N) 2x BLKG UP SLOPE OF (N) IN -VENT COR-A-VENTS TO HAVE (3) 2'0 HOLES EA RAFTER BAY (CTV) To I.. N :, Lail Z O Z Lu (N) ROOF VENTILATION CALCULATIONS: VENTILATION REQUIRED: 2,134 SF. (144/300) = 1,192.3 S.I. 5090 OF AREA REQUIRED m RIDGE = 896.2 S.I. VENTILATION PROVIDED: 61'-9' RIDGE VENT 9 18 5.115F = 1,2195 S.I. IC'-10' EAVE VENTS (EVERY BAY) 235 S.I)FT = 25.455.1. 94'-O' COR-A-VENTS • 6.15 S.I)FT = 63456.1. TOTAL PROVIDED = 1,819.45 S.I. F� O J� O coon�w ~ Q elf U • > z a_ w a.i Q) q O 0 R � O o O CEIV D • W Q "rram^^ v1 • • • • • N CITY OF EDMONDS DEVELOPMENT SERVICES �r 4¢ _4 N o � Q �WN � c1lo w law w RFOOF�^ 54' MIN � � 12" 42" MIN q N MAX 39'-41' Lol �) J / 2 3/4' W I-1/2' MIN FJ x -q - x � m z a -CIA N Q - - - -o O ctl z n, � e Sao m ``' o "' \ TOILET SEAT COVER DISPENSER LAVATORY DISPENSER/WASTE DOOR SPECIFIED RECEPTACLE PER PLANS W � 5 4� N5 q� c MOUNTING HEIGHTS DIAGRAM k °o q O A NTS Q P 0 (N) 36' GRAB BAR PER 0 � o W ICC/ASNSI REQUIREMENTS 3 7 MAX M �, �✓ \ N N � 4 6 o W w (N)18' GRAB BAR PER �' i '� F--� O 0. ICC/ASNSI REQUIREMENTS D ; �C ICC/ANSI SECTION 6043 60' MIN WIDE CLEARANCE , �--� _ 0 W 8 2 9 PERP FROM SIDE WALL AND 56' MIN DEEP CLEARANCE 4 4 O v PERP FROM REAR WALL. NO OBSTRUCTIONS WITHIN THIS • a CLEARANCE 3,41 1 3 0 11 1 ATE UNDERSINK PIPES I A4 rrTTl� • N (N) DOOR PER PLAN SHEET VINYL FLOOR TO RUN CONT UP 4 ONTO 2 [--� �?i oWALLS MIN 6 FOR COVE BASE 5 Cn Q o W N 1 co F2_1 q ----L--I------------------- > U W � Q (N) IS' CxRAB BAR PER u 'L[) ~ a z ICC/ASNSI REQUIREMENTS ------ 9 � � • O �----------------- --- U W o > w a (N) 42' CRAB BAR PER � 6cn �' ICC/ASNSI REQUIREMENTS 3 / 601 `\04 z w w '1' 8 �'�'o(/Na w v W V) M W Z FRP WAINSCOT, TYP ; o VINYL COVE BASE TYP 0 F3_1F4_1 W z q Q J 0- 0 0 04 1-11 B RESTROOM INTERIOR ELEVATIONS SINGLE H AN DI -CAP STALL o �.4NTS �.4SCALE: 1/2' = 1'-0" w m X :To � R CESep 28 IV D Z CITY OF EDMONDS DEVELOPMENT SERVICES LL RESTROOM FI XTU SCHEDULE ITEM DESCRIPTION MFR STYLE QtY Ol HANDICAP MOUNTED FLUSH V TOILET (BOWL � TANK) PER OWNER 1 O WALL MOUNTED LAV PER OWNER 1 O GRAB BA RIzONtAL � VERTICAL PER ICC/ASNSI REQUIREMENTS) PER OWNER 1 O t SEAL DISPENSER PER OWNER 1 WALL MOUNTED SOAP DISPENSER PER OWNER 1 O TOWEL pfSPENSER/I.UAStE RECEPTACLE PER OWNER 1 O IS'x24' MIRROR PER OWNER 1 OS TOILET PAPER DISPENSER PER OWNER 1 O9 RESTROOM FAUCET SET (LEVER STYLE) PER OWNER 1 10 NOT USED PER OWNER 1 11 OPEN FRONT SEAL FOR WATER CLOSET PER OWNER 1 12 FLOOR DRAIN PER OWNER 1 rr\ q rr \\ W ^^ o0 I �r 4¢ -4 N o � Q �wN � � w W 0 w J v1 [[O o O 1 M !� ACOUSTICAL N CEILING TILE SEISMIC BRACE — t� PER U.B.C. l2'x4') W STANDARD 25-2 C Lr� NOTE: PROVIDE CROSS -BRACING FOR SUSPENDED ACOUSTICAL CEILING SYSTEM 12' O.C. BOTH 6'-0' 12'-0' MAX. WAYS WITH NO 12 GAUGE WIRES PER ASTM C635 AND ASTM C636. THE HORIZONTAL RESTRAINT MAX. B POINTS FOR THE LATERAL FORCE BRACING SHALL BE PLACED NOT MORE THAN 12'-0' O.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-O' FROM EACH WALL. TO FACILITATE o • INSTALLATION MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER Q� MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS WALL MAINTAINED At THE OTHER TWO WALLS IN SUCH WAY AS TO BE INDEPENDENT OF THE WALL STRUCTURE AND SHALL BE BRACED BY LATERAL FORCE BRACING At 12'-0' O.C. MAXIMUM. ACCOUSTICAL CEILING SYSTEMS SHALL COMPLY WITH IBC 808 �� M NON-COMBUSTIBLE STRUT CAPABLE OF RESISTING VERTICAL COMPONENTS INDUCED _ BY BRACING WIRES. FASTEN SECURELY TO TYPICAL SEISMIC BRACING FOR SUSPENDED STRUCTURE ABOVE ACCOUSTICAL CEILING GRID SYSTEM D o W 12 GA VERT WIRE (TYP) O v a 12 GA VERT HANGER WIRE Q 8 MAX 8 MAX 15 = .c • o 4'-0' O.C. BOTH WAYS � 3 TURNS MIN (TYP) O �w N MAIN RUNNER OR CROSS TEE `0,' 450 LATERAL FORCE BRACING 4 EA Q o W N 12 GA WIRE SECURED TO MAIN R W/IN rn 2' OF CROSS TEE INTERSE 4 SPLAYED U 450 90' FROM EA OTHER' ' O.C. IN BOTH Q O DIRECTIONS W/ FI INT W/IN 4'-0' FROM EA WALL ~ PROVIDE 1/2' SPACE OPP WALL Q w N NNER ACCOUSTICAL TILE W Q � z oCROSS TEE WALL ANGLE l2' MIN PER CODE) 0 w • w ATTACH MEMBER 9 PERIMETER 4 UNIT 9631 UNIT 9625 UNIT 9619 UNIT 9613 W v W Z TWO ADJACENT WALLS ONLY NO WORK NO WORK NO WORK o 0 M z < q 0 ("A SUSPENDED CEILING BRACING REFLECTIVE CEILING PLAN & 2ND FLOOR Z �21NTS SCALE: 1/4' = 1'-0' SEE LIGHTING SCHEDULE ON A2.0 FOR BAL OF INFO � a J 0- 0 0 0 N O ON CA o O N o w X Q� R CEIV D Z Sep 28 CITY OF EDMONDS DEVELOPMENT SERVICES LL rr\ rr \\ w ^^ I a 0 00 0 00 0 0i 91 m 0 X 0 Z N TYPICAL ROOF CONSTRUCTION: (N) DIMENSIONAL COMP ROOFING W/ (N) 30# BLDG PAPER OVER (N)1/2' NOM PWD/OSB SHTG OVER (N)1x12 SHTG -OR- (N) 3/4' T4G NOM PWD/OSB (SOLID) SHTG 4 (NNE) 2x6 RAFTERS • IV O.C. TYPICAL CEILING CONSTRUCTION: (E) 2x6 CEILING JOISTS • I6' O.C. W/ R-49 BLOWN -IN INSULATION W/ (E) GCB TO UNDERSIDE OF CEILING JOISTS - PROVIDE (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL WHERE GCB FINISHES REPLACED (E) 2x BLKG W/ 3-(N) 2'0 SCREENED HOLES EVERY OTHER BAY (E) SOFFIT - TYR UNO (E) 2ND FLR BALCONY — NO WORK (E) ALUMINUM GUARDRAILS - TYR UNO (E) TILES OVER (E) CONIC (E) ASPHALT (E) 2x4 EXTERIOR WALL CONSTRUCTION (UNIT 9625 4 9623): (E) WOOD -LAP SIDING OVER (E) BLDG PAPER OVER (E)1/2' NOM PWD SHTG OVER (E) 2x4 STUDS a 16' O.C. W/ (E) INSULATION W/ (E) GWB TO INTERIOR (E) OFFICE 3 SMOKE SEAL 4 PAINT UNIT 9619 of (E) KITCHEN (N) INTERIOR FINISHES UNIT 9621 (E)KN) COLLAR TIES 4 (E) RIDGE SPLINE PER STRUCT (E) 2x4 CRIPPLE WALL OVER (E) 6x12 (FF) BM PER STRUCT TYPICAL (E)1HR PARTY WALLS: (E) 2x4 WOOD STUDS • 16' O.C. W/ (N) 3-1/2' GLASS FIBER GLASS INSULATION 4 (E) GWB 6 UNIT %19 4 (N) 5/8' TYPE 'X' GWB 9 UNIT 9625 (E) 2x4 EXTERIOR WALL CONSTRUCTION (UNIT 9621): (E) WOOD -LAP SIDING OVER (E) BLDG PAPER OVER (E)1/2' NOM PWD SHTG OVER (E) 2x4 STUDS • IV O.C. W/ (N) R-15c UNFACED GATT INSULATION W/ (N) 5/8' TYPE 'X' GWB 4 I -PERM PVA PAINT TO INTERIOR KLING FINISHES 9623 (E) 50G 0 (E) OPEN OFFICE SPACE (N) INTERIOR FINISHES UNIT 9625 (E) OOD STUDS • 16' O.C. W/ iOM'GWB EA SIDE (E) 2x4 CRIPPLE WALLKN) SW PER STRUCT (E) FLOOR CONSt ON: (N) FLOOR C GS (PER OWNER/CONTR) OVER (E)1-1/2' TOPPING OVER (E) lx12 FLOOR SHTG OVER (E) 2 OOR JOISTS SPCD 12' O.C. W/ (N) 5/8' TYPE 'X' GCB 0 lN)1/2' RESILIENT CHANNEL • UNDERSIDE OF JOISTS (E) FLOOR CONSTRUCTION: (N) FLOOR COVERINGS (PER OWNER/CONTR) OVER (E)1-1/2' CONC TOPPING OVER (E) IA2 FLOOR SHTG OVER (E) 2x12 FLOOR JOISTS SPCD 12' O.C. W/ (N) 5/6' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL im UNDERSIDE OF JOISTS (E) INTERIOR WALLS (UNIT (3623) (E) 2x4 WOOD STUDS m 16' O.C. W/ (E) GWB EA SIDE BUILDING SECTION SCALE: 3/8" = 1'-0' (E) DINING RM (N) INTERIOR FINISHES UNIT 9621 (E) BRONZING AREA (N) CEILING FINISHES UNIT 9623 WHERE (N) BLKG 3-(N) 2'0 HOLE5i PLED, PROVIDE VENTING (E) WOOD -SOFFIT TO UNDERSIDE OF (E) CEILING JOISTS - TYR UNO (E) WRAPPED POST 4 BM - TYP UNO (E) 2ND FLR BALCONY NO WORK (E) WALKWAY CONSTRUCTION: (E) 4' CONIC TOPPING OVER (E) SHTG OVER (E) FLOOR JOISTS W/ (E) SOFFIT TO UNDERSIDE OF JOISTS ° (E) EXTERIOR BELOW GRADE WALLS CONSTRUCTION: (E) GWB • INTERIOR OVER (E) 2x4 STUDS • 16' O.C. W/ (E) INSULATION OVER (E) (o' CONC BASEMENT WALL N Qo N 0 I CITY OF EDMONDS DEVELOPMENT SERVICES 9E�_ • • TYPICAL ROOF CONSTRUCTION: (N) DIMENSIONAL COMP ROOFING W/ (N) 300 BLDG PAPER OVER (N)1/2' NOM PWD/OSB SHTG OVER (N) lxl2 SHTG -OR- (N) 3/4' T4G NOM PWD/OSB (SOLID) SHTG 4 (NNE) 2x6 RAFTERS 6 16' O.C. TYPICAL CEILING CONSTRUCTION: (E) 2x6 CEILING JOISTS @ 16' O.C. W/ R-49 BLOWN -IN INSULATION W/ (E) GCB TO UNDERSIDE OF CEILING JOISTS - PROVIDE (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL WHERE GCB FINISHES REPLACED TYPICAL (E) 2x4 EXTERIOR WALL CONSTRUCTION: (N) COMP SIDING PER OWNER/CONTR OVER (N) 300 BLDG PAPER OVER (N)1/2' NOM PWD/OSB SHTG OVER (E) lx8 SNIP -LAP SHTG OVER (E) 2x4 STUDS 6 IV O.C. W/ (N) R-15c UNFACED BATT INSULATION W/ (N) I/2' GWB d 1-PERM PVA PAINT TO INTERIOR (E) 2x4 STUDS 6 IV O.C. W/ (N) 3-1/2' GLASS FIBER INSULATION 4 2-(N) LAYERS OF 5/8' TYPE 'X' GWB 6 UNIT 9627 WHERE GWB REPLACED 4 2-(E) LAYERS OF GWB 9 ADJACENT UNITS I� 0 ., v-- WOOD STUDS 9 16' O.C. Wl kYPE 'X' GWB a ATTIC SIDE (E) 6xl4 BM - NO Na -.44, RECEPTION PAINTNa SMOKE SEAL 4 UNIT %31 (E) STAIRS (N) CLG FINISHES UNIT %21 . I T ° (E) OPEN OFFI (N) INTERIOR FINISHES UNIT 9625 TYPICAL (E)1HR PARTY WALLS: (E) 2x4 WOOD STUDS G 16' O.C. W/ (N) 3-1/2' GLASS FIBER GLASS INSULATION 4 (E) GWB m SIDE OF UNITS 9631 4 9619 4 (N) 5/8' TYPE 'X' GWB a UNIT 9625 SIDE (N) FLOOR CONSTRUCTION: (N) FLOOR COVERINGS (PER OWNER/CONTR) OVER (E)1-1/2' CONIC TOPPING OVER (E) lxl2 FLOOR SHTG OVER (E) 2x10 FLOOR JOISTS SPCD 12' O.C. Wl (E) GCB TO UNDERSIDE OF JOISTS - PROVIDE (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL WHERE GCB FINISHES REPLACED UNIT 9621 110 PA (E) OFFICE (N) CEILING FINISHES Wli 9621 Wli 9623 (E) SOG CE AREA (E) FRONT OFFICE SMOKE SEAL 4 PAINT UNIT 9619 (N) FLOOR CONSTRUCTION: (N) FLOOR COVERINGS (PER OWNER/CONTR) OVER (E)1-1/2' CONIC TOPPING OVER (E) IA2 FLOOR SHTG OVER (E) 2xl2 FLOOR JOISTS SPCD 12' O.C. W/ (E) GCB TO UNDERSIDE OF JOISTS - PROVIDE (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL WHERE GCB FINISHES REPLACED (E) STORAGE � NO WORK BMA �Ir �1, TY� fARTT WALL - BUILDING SECTION 5C:ALE: 3/8' = 1'-0' • • • • • • I CITY OF EDMONDS DEVELOPMENT^ SERVICES 2-(N) 5/8' TYPE 'X' GWB EA SIDE uo// OF(N)CHASE (N) KITCHEN HOOD EXHAUST DUCT (N) SILO ETAL CHASE COVER PER (N) EXTERIOR RATED FLEX 2' CLEAR FROM CONTR/O OVER (N) 2x4 FRAMING CAULK AROUND ZERO CLEAR (N) Fly" IG • 12' O.C. W/ PERS AS RQD FOR DUCT PENETRATION PER CONTR ADEQUATE SL FOR DRAINAGE WALLS W/ I�PER CONTR (N) WOOD -LAP SIDING TO MATC R (N) 300 BLDG PAPER OVER (N)1/2 PWD/OSB SHTG OVER (N) 2x4 STUDS (N) 26GA GALV FLASHING (N) DIMENSIONAL COMP ROOFING OVER (N) 300 BLDG PAPER OVER (N) 3/4' NO PWD/OSB (SOLID) SHTG OVER (N)1/2' Nc PWD/OSB SHTG 4 (N)/(E) 2x6 RAFTERS Is 16' O.C. 2 -(N) LAYERS OF 5/8' TYPE 'X' GWB EA SIDE OF (N) CHASE ATTIC (N) 2x4 CHASE WALL W/ FRMG PER CONTR (N) WOOD -LAP SIDING TO MATCH OVER (N) 300 BLDG PAPER OVER (N)1/2' NOM PWD/OSB SHTG (N) 26GA GALV FLASHING (N) DIMENSIONAL COMP ROOFING OVER (N) 300 BLDG PAPER OVER (N) 3/4' NOM PWD/OSB (SOLID) SHTG OVER (N)1/2' NOM PWD/OSB SHTG 4 (N)/(E) 2x6 RAFTERS • �titer_ 2-(N) LAYERS OF 5/8' TYPE 'X' GWB EA SIDE OF (N) CHASE SO �� ATTIC (N) 2x4 CHASE WALL FRMG PER CONTR (E) GCB W/ ISOLATED REPAIRS TO MATCH (CTV) (N) 5/8' TYPE 'X' GCB OVER (E) GWB W/ ISOLATED REPAIRS TO MATCH (CTV) lj�Ly, (N)1/2' RESILIENT CHANNEL a • CLG/ROOF o21 .A 00 UNIT 96 1] 0 N 0 0 91 m 0 X 0 z N LL (E) 2x4 CHASE WALL PER PLANS (E) GWB W/ ISOLATED REPAIRS TO MATCH (CTV) (E) 2x10 FLOOR JOISTS • 12' O.C. (E)1-1/2' CONC TOPPING OVER - (E) lxl2 FLOOR SHTG (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL 6 2ND FLOOR OF 5/8' TYPE 'X' GWB 2-(N) LAYERSNCE YPE 'X' GWB EA SIDE OF (N(E) 2x10 FLOO (E)1-1/2' CONIC TOPPING (E) IA2 FLOOR SHTG ' O.C. (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL 2-HR FIRE -RATED CHASE NTS Lu U z M (N) 2x4 KITCHEN HO SST DUCT CHASE (E)1-HR RATED SEPARTION SEE DTL 5/A32 2-HR FIRE RATED CHASE NTS SHOWN • 2ND FLOOR (E) 2x6 CEILING JOISTS s (N) 5/8' TYPE 'X' GWB Ole (N)1/2' RESILIENT CHANNEL 1-HR FIRE -RATED ROOF/CEILING NTS GA FILE NO. RC 2603 (MODIFIED FOR (E) CONSTRUCTION) RAP INTERIOR OF 1-HR RATED ASSEMBLY PENETRATION CAVITIES W/ (2) LAYERS OF 5/8' TYPE 'X GWB AS SHOWN EXHAUST FANS, PIPES, DUCTS ETC RAP INTERIOR OF FLOOR PENETRATION CAVITIES W/ (2) LAYERS OF 5/8' GWB TYPE 'X' AS SHOWN PENETRATION (N) 2x BLKG AS RQD (E) 2x FLOOR JOISTS PER PLAN (N) 5/8' TYPE 'X' GCB OVER (N)1/2' RESILIENT CHANNEL FIRE -RATED CEILING PENETRATIONS NTS (E)1-1/2' GYPCRETE 0"' (E) IXI2 FLOOR SHTG (N) 5/8' TYPE 'X' GWB ... �. (N)1/2' RESILIENT CHANNEL )OR JOISTS • 12' O.C. 2-HR FIRE -RATED FLOOR NTS GA FILE NO. FC 5110 (MODIFIED FOR (E) CONSTRUCTION) (E) GWB - NO DAMAGE 2-(N) LAYERS OF 5/8' TYPE e ,� 1^ (E)SEgol`L` ` ANS PRO WPPM LAYER 5/8' GWB VERT PWI`fdP5 • MIN INTERVALS OF 10'-0' SECURELY FASTENED IN PLACE PER 2015 IBC SECTION 11822 - TYP • ALL PARTY WALLS - EXTEND THRU CONCEALED SPACES 9 ATTIC PROVIDE MINERAL FIBER INSUL IN LIEU OF GWB a SEPARATION WALLS BETWEEN UNITS 2-HOUR FIRE -RATED SEPARATION WALL NTS GA FILE NO. WP 4136 (N) 5/8' TYPE 'X' GWB EA SIDE (E) SEPARATION WALL PER PLANS PROVIDE (1) LAYER 5/8' GWB VERT FIRESTOPS IS MIN INTERVALS OF 10'-0' SECURELY FASTENED IN PLACE PER 2015 IBC SECTION 11822 - TYP • ALL PARTY WALLS - EXTEND THRU CONCEALED SPACES 9 ATTIC PROVIDE MINERAL FIBER INSUL IN LIEU OF GWB 9 SEPARATION WALLS BETWEEN UNITS 1-HR FIRE -RATED SEPARATION WALL NTS GA FILE NO. WP 3645 (N) 5/8' TYPE 'X' GWB (E) WOOD -LAP SIDING OVER (E) BLDG PAPER OVER (E)1/2' PWD SHTG 1-HR FIRE -RATED EXTERIOR WALL NTS GA FILE NO. WP 6105 (MODIFIED FOR (E) CONSTRUCTION) CITY OF EDMONDS DEVELOPMENT SERVICES • • • OWN