BLD2020-1000+LIGHTING+9.28.2020_8.54.40_AM2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 General Info Project Title: Firdale Village Fire Restoration Date 9/28/2020 PROJ-SUM form Project Street Address: 9617 Firdale Ave - Unit 9631 For Building Department Use shall be provided as Project City, County, Zip: Edmonds, WA 98020 a cover sheet for all compliance form Project Owner or Rep: Jesse Binford submittals. Project Title shall match Jurisdiction: City of Edmonds project plans title block. Project Description New Construction and Additions Select all that apply to the ❑ New Building ❑Building Addition scope of project. Select Addition + Existing Existing Building Retrofit or Alteration + Existing if the existing building will be❑ Alteration ❑ Change of Occupancy ❑ Change in Space Conditioning combined with the addition or alteration to demonstrate ❑ Historic Building compliance per Section C502.1 or C503.1. Building Elements Scope - Select all that apply ❑ All❑ Building Envelope ❑ Mechanical Systems ❑ Service Hot Water Systems ❑ Lighting Systems ❑ Electrical Systems All Commercial a Group R - R2, R3, & R4 (D Mixed Use over 3 stories and all R1 Occupancy Type P Y YP Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R occupancies. Mixed Occupancy - Building is three stories or less above grade and it has both Commercial and Group R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Select all that apply to the scope of project ❑ Fully Conditioned ❑ Semi-heated2 ❑ Refrigerated Spaces (Warehouse and/or Walk-in') ❑ Low Energy Space Category3 Space Conditioning Eligible Low Energy Spaces Categories ❑ Unconditioned ❑ Low energy heating/cooling capacity Wireless service ❑ Greenhouse4 ❑ Equipment building equipment shelter Floor Area and Floors Above Grade Building Gross Conditioned Floor Area Project Gross Conditioned Floor Area Stories 2 9,198 651 Compliance Method 1 - General C Compliance Method 2 - Total Building Compliance Method 1 - Projects shall demonstrate compliance with all applicable mandatory and General Compliance prescriptive requirements of this code. Refer to C401.2, Item 1 for more information. Compliance forms to include with a Prescriptive submittal: All applicable ENV, LTG, and MECH. Path Compliance Method 2 - Projects complying via total building performance (TBP) shall include a summary of results from a whole building energy model per Section C407 and shall demonstrate compliance with all applicable mandatory provisions in this Code. Refer to Section C401.2, Item 2 for more information. Compliance forms to include with a TBP submittal: PROJ-SUM, ENV-CHK, LTG-EXT, LTG-CHK, and all MECH forms except MECH-ECONO and MECH-VENT (pending). Note 1 - Refrigerated Spaces - They shall comply with the envelope and refrigeration equipment requirements in Section C410. Warehouse coolers and freezers shall also comply with the envelope requirements in C402. C410 takes precedent for overlapping requirements. Note 2 - Semi -heated Spaces - If heated with equipment other than electric resistance may take an exemption for wall insulation. All other envelope assemblies shall comply with the thermal envelope provisions. Note 3 - Exemptions For Low Energy Spaces - Low Energy spaces are exempt from all provisions in WSEC Section C402 Building Envelope, however all other applicable provisions in the Code do apply including lighting, mechanical, service water heating, etc. Note 4 - Eligible Space Conditioning For Low Energy Greenhouses - Greenhouses are defined as spaces that maintain a specialized sunlit environment that is used exclusively for cultivation, protection and maintenance of plants. Cooling with outside air and/or evaporative cooling, and any form of heating equipment, are allowed under the Low Energy Greenhouse category. Greenhouses with cooling equipment that requires a condensing unit are NOT eligible. 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 General Info I Project Title: Firdale Village Fire Restoration Date 9/28/2020 C406 Additional Building level efficiency options: Current Scope Previous Projects C406.8 Enhanced envelope performance ❑ ❑ Efficiency Package Options Summary C406.9 Reduced air infiltration ❑ ❑ A minimum of two Options are required for new construction, C406.5 On -site renewable energy ❑ ❑ Building area level efficiency options and change in space conditioning or occupancy C406.2 More efficient HVAC equipment ❑ ❑ projects. Select all Options included in C406.6 Dedicated outside air systems (DOAS) ❑ ❑ the current project scope. Also select Options complied C406.7 Reduced energy use in service water heating ❑ ❑ with under previous projects (shell and core, other tenant C406.3 Reduced lighting power ❑ ❑ spaces in building, etc) Buildings with multiple tenant C406.4 Enhanced digital lighting controls ❑ ❑ spaces may comply with different options (mix & C406 Comments: match). Options are required for all space conditioning categories. Include discipline specific information for C406 options in ENV -SUM, LTG -SUM and Refer to SBCC website for official interpretations regarding C406 provisions. 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Project Info Project Title: Firdale Village Fire Restoration Date 09/28/2020 Applicant Info. Company Name: BC Investigative Engineers For Building Department Use Company Address: 3605 C St NE, Auburn, WA 98002 Provide contact information for Applicant Name: Jesse Binford individual who can respond to inquiries about information lApplicant Phone: 253-833-5557 provided. Applicant Email: jbinford@bcie.net Project Description ❑ New Building ❑ Addition 0 Alteration ❑ No Envelope Scope Envelope Project Scope Q All Commercial ❑ Group R - Commercial ❑ Mixed Use - Commercial + Group R Select all that apply. ❑ Semi -heated ❑ Refrigerated Cooler ❑ Refrigerated Freezer ❑ Equipment Building Envelope Description Fire Damage repair: Smoke seal & paint. Isolated ceiling and wall repairs Provide brief description of the project and relevant supporting documentation. If project includes multiple Target Insulation Allowance areas, and/or is demonstrating compliance as an Addition + Existing, Alteration + Existing, or Addition + Alteration + Existing project, provide a brief summary of the approach to whole building compliance. Air Barrier Testing ❑ Air barrier testing per Section C402.5.1.2 included in project scope Air barrier testing is required for all new construction projects. Testing criteria is 0.40 ❑ Additional Efficiency Package Option - C406.9 Reduced Air Infiltration cfm/ft2 under test pressure of 0.3 inch w.g. Fire Damage repair. Only exterior work is roof replacement. To comply with C406.9, demonstrate that Q Testing not required. Explanation, No changes to existing envelope. measured air leakage of building envelope Compliance Documentation Scope and Method Scope of This Calculation ❑ New Building ❑ Addition ❑� Alteration ❑ No Envelope Scope Target Insulation Allowance O Fully Conditioned - Commercial, Group R, Mixed Use Sets the title and calculations in the compliance forms. Selection required ❑ Semi -heated ❑ Refrigerated Cooler ❑ Refrigerated Freezer to enable forms. If project includes more than one Target Insulation Allowance area, and/or if project includes addition and alteration areas complying independently, for each area complete an ENV -SUM form Rows 16-46 and either an ENV -PRESCRIPTIVE form, or ENV-UA + ENV-SHGC forms if demonstrating compliance via component performance. Envelope Compliance Path Q Prescriptive ❑ Component Performance Selection required to enable forms. Component Performance ❑ Change of Occupancy (C503.2) / Conditioning (C505) - 10% higher UA allowed Calculation Adjustments ❑ Additional Efficiency Package Option - C406.8 Enhanced Envelope - 15% lower UA required Additions ❑ Addition stand alone ❑ Addition + Existing Addition stand alone - Complete Vertical Fenestration and Skylight Area Calculation. Enter total existing -to -remain wall, roof, vertical fenestration and skylight areas as EXISTING. Enter total addition envelope assembly areas as NEW. If resulting total building WWR exceeds 30% and/or SSR exceeds 5%, refer to C502.2.1 and C502.2.2 for prescriptive compliance alternatives. If complying via component performance, complete ENV-UA per instructions for addition stand alone projects. Addition + existing - Complete ENV-UA per instructions for addtion + existing projects. Alterations - ❑ Replacement windows only, or resulting ❑ Total building WWR increased by Fenestration and Skylight total building WWR <_ original WWR ❑ Replacement skylights only, or resulting ❑ Total building SRR increased by alteration total building SRR <_ original SRR WWR and SRR not increased - Vertical Fenestration and Skylight Area Calculation not required. WWR and/or SRR increased - Complete Vertical Fenestration and Skylight Area Calculation. Enter total existing -to -remain wall, roof, vertical fenestration and skylight areas as EXISTING. Enter total altered envelope assembly areas as NEW. If resulting total building WWR exceeds 30% and/or SSR exceeds 5%, refer to C503.3.2 and C503.3.3 for prescriptive compliance alternatives. If complying via component performance, complete ENV-UA per instructions for alteration + existing projects. 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Project Title: Firdale Village Fire Restoration Date 09/28/2020 Vertical Fenestration and Skylight Area Calculation Total Vertical Fenestration Area (rough opening) NET Exterior Above Grade Wall Area Total Skylight Area (rough opening) NET Exterior Roof Area Prescriptive Path - Enter envelope sf values directly into this section of ENV -SUM New 20 0 0 0 Existing 40 116 0 651 for vertical fenestration, skylights, net walls and roof. For Additions and Alterations, refer to these sections in ENV -SUM for further instructions. Total 60 116 0 651 Component Performance - When this Envelope Compliance Path is selected, write -protection of this section is enabled. Enter envelope sf values for all assemblies into the ENV-UA form. Envelope information from ENV-UA will auto -fill into this section of Vertical u Fenestration -to- 34.1 /o Wall Ratio (WWR) Skylight -to -Roof Ratio (SRR) SRR Project exceeds maximum vertical fenestration area allowed for Prescriptive compliance. Vertical Fenestration Area Compliance May comply prescriptively using a vertical fenestration alternate or via Component Performance with Target Area Adjustment. NO SKYLIGHT PROPOSED. COMPILIES WITH MAXIMUM ALLOWANCE. Skylight Area Compliance Vertical Fenestration D High performance fenestration U-factors and SHGC per C402.4.1.3 Alternates C) Dedicated outdoor air system per C402.4.1.4 and C403.6 Show locations of qualifying daylight zone i) In buildings >_ 3 stories, 25% or more of NET floor area is in DLZ per C402.4.1.1 (DLZ) areas and ft2 on project plans. In buildings < 3 stories, 50% or more of CONDITIONED floor area is within DLZ per For Daylight Zone Area Calculations - C402.4.1.1 a) Sidelight areas include primary+ Daylight Zone Calculations secondary daylight zone areas. Not Selected. No Calculations Sidelight Daylight Toplight Daylight Percent Daylight b) Include overlapping toplight and sidelight Required Zone Area Zone Area Zone Area daylight zone areas under Toplight. c) Net floor area definition in Chapter 2. Spaces in Single Story List all enclosed spaces that exceed 2,500 W, have ceiling height greater than 15 ft, and are Building Requiring Skylights space types required to comply with this provision. Indicate aperture with 'AP" prefix (AP 1.1 %) In these spaces a minimum of 50% of the Space Space Area (ft2) DLZ Area (ft) SRR or Aperture Exception floor area shall be within a skylight daylight zone (DLZ). Refer to C402.4.2 for requirements. SRR = Skylight to roof ratio Envelope Exemptions Low Energy and Semi -heated Spaces Low energy spaces per C402.1.1 Item 1 are exempt from the thermal envelope provisions. Semi -heated spaces heated by systems other than electric resistance are exempt from wall insulation provision only per C402.1.1.1. Complete Low Energy and Semi -Heated Spaces table in MECH-SUM to verify eligibility based on installed peak heating and cooling capacity per sf. Equipment Buildings Wall Insulation R-Value Roof Insulation R-Value Overall Average U-Factor Equipment buildings are exempt from the thermal envelope provisions per C402.1.2. Equipment Building Envelope Electronic equipment power (watts/sf) The following shall be met to be eligible: building size <_ 500 sf, average wall/roof U- factor <_ U-0.20, electronic equipment load >_ Heating system output capacity (Btu/hr) 7 watts/sf, heating system output capacity <_ Cooling capacity (Yes/No) 17, 000 btu/h. Cooling system capacity not limited. 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Minimum Requirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration. Refer for Prescriptive Compliance to Tables C402.1.3, C402.1.4 and C402.4 in the 2015 WSEC for important footnotes that apply to these tables. Refer to Section C402 for all applicable requirements for each envelope element type and applicable exceptions. Refer to Section C410 for all applicable information for refrigerated spaces. Prescriptive Path Table C402.1.3 Notes 1,7 Insulation Minimum R-Value Table C402.1.4 Notes 1,2 Assembly Maximum U-factor Occupancy Group All Other Group R All Other Group R Opaque Elements Roofs Insulation Entirely above Deck R-38 c.i. R-38 c.i. U-0.027 U-0.027 Metal Building with thermalspacer block Note 3 R-25 + R-11 Ls R-25 + R-11 Ls U-0.031 U-0.031 Attic and Other R-49 R-49 U-0.021 U-0.021 Joist or single rafter R-49 R-49 U-0.027 U-0.027 Walls, Above grade Mass R-9.5 c.i. Note 6 R-13.3 c.i. U-0.104 Note 6 U-0.078 Mass transfer deck slab edge No R-Value for prescriptive compliance U-0.200 U-0.200 Metal Building R-19 c.i. R-19 c.i. U-0.052 U-0.052 Steel Framed R-13 + R-10c.i. R-19 + R-8.5 c.i. U-0.055 U-0.055 Wood Framed and Other R-21 w/ int. frame R-21 w/ int. frame U-0.054 U-0.054 Below Grade Wall Note 4 Same as above grade Same as above grade Floors Mass R-30 c.i. R-30 c.i. U-0.031 U-0.031 Steel Joist R-38 + R-10 c.i. R-38 + R-10 c.i. U-0.029 U-0.029 Wood Framed and Other R-30 R-30 U-0.029 U-0.029 Slab -On -Grade Floors Unheated R-10 for 24 in. (from top of slab) F-0.54 F-0.54 Heated Note 5 R-10 perimeter & under entire slab F-0.55 F-0.55 Opaque Doors Swinging No R-Value for prescriptive compliance U-0.37 U-0.37 Nonswin in(Roll-up or sliding) R-4.75 I R-4.75 U-0.34 U-0.34 Table C402.4 - 0-30% of wall area, or 30%-40%per Section C402.4.1.1 DLZ or Section C402.4.1.4 DOAS Section C402.4.1.3 High Performance Fenestration Option - 0-40% of wall area Fenestration Assembly Maximum U-factor Notes 1,2 Vertical Fenestration Nonmetal framing U-0.30 U-0.30 U-0.28 U-0.28 Metal framing (fixed) U-0.38 U-0.38 U-0.34 U-0.34 Metal framing (operable) U-0.40 U-0.40 U-0.36 U-0.36 Entrance doors U-0.60 U-0.60 U-0.60 U-0.60 Skylights Skylights U-0.50 U-0.50 U-0.50 U-0.50 Fenestration Assembly Maximum SHGC Factor Vertical Fenestration PF<0.2: north - SHGC=0.53; all other SHGC=0.4 0.25 PF < 0.5: north - SHGC-0.58; all other - SHGC-0.48 PF >_ 0.5: all orientations - SHGC-0.64 PF<0.2: north - SHGC=0.46; all other SHGC=0.35 0.25 PF < 0.5: north - SHGC-0.51; all other - SHGC-0.42 PF >_ 0.5: all orientations - SHGC-0.56 Skylights SHGC-0.35 SHGC-0.35 C410.2 Refrigerated Spaces Insulation Insulation Minimum R-Value Assembly Maximum U-factor Freezers - Walk-in and Warehouse Roof / Ceiling R-32 U-0.030 Wall R-32 U-0.030 Door R-32 U-0.030 Door - transparent reach -in triple -pane, heat -reflective treated or gas Floor R-28 U-0.035 Coolers - Walk-in and Warehouse Roof / Ceiling R-25 U-0.039 Wall R-25 U-0.039 Door R-25 U-0.039 Door - transparent reach -in double -pane, heat -reflective treated & gas fill, or comply with freezer door req. Floor I No Requirement 5 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Ls = Liner system -- A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed, unfaced insulation rests on top of the membrane between the purlins. Refer to Section A102.2.5.4. c.i. = Continuous insulation -- Insulation that is continuous across all structural members without thermal bridges other than service openings and penetrations by metal fasteners with a x-sectional area of less than 0.04% of the opaque surface area of the assembly. Components with more than 0.04% metal penetrations may be eligible to follow the alternate CI values below. int = Intermediate framing -- Includes insulated headers, corners and interior partition wall to exterior wall intersections. Refer to Section A103.2 for framing definitions. ootnote Summary: Each table in the 2015 WSEC has footnotes applicable to specific information provided in the table. This footnote summary provides only abbreviated details from these footnotes. Refer to 2015 WSEC for complete footnote information. Note 1 - Assembly descriptions can be found in Chapter 2 and Appendix A. Note 2 - Use of assembly U-factors, C-factors and F-factors from Appendix A and Chapter 3 are required unless otherwise allowed by the provisions of this Code. Note 3 - For metal building roofs where using R-value compliance method, a thermal spacer block with minimum thickness of 1/2-inch and minimum R-value of R-3.5 is required. Otherwise use the U-factor compliance method. Note 4 - Where heated slabs are below -grade, they shall comply with the F-factor requirements for slab -on -grade heated slabs. Note 5 - Heated slab F-factors shall be determined specifically for heated slabs. Unheated slab F-factors shall not be used. Note 6 - CMU walls in all occupancies other than Group R may be eligible for reduced insulation if all provisions stated in applicable footnote are met. Refer to Footnote D in Table C402.1.4 or Footnote C in Table C402.1.3 for eligibility requirements. Note 7 - Components with continuous insulation but with metal penetrations / connections may be eligible for alternate continuous insulation R-values if all provisions in applicable footnote are met. Refer to alternate prescriptive R-values in table below and Footnote G in Table C402.1.3 for eligibility requirements. Alternate continuous insulation nominal R-values This alternate nominal R-value compliance option is allowed for projects complying with all of the following: 1. The ratio of the cross -sectional area, as measured in the plane of the surface, of metal penetrations of otherwise continuous insulation to the opaque surface area of the assembly is greater than 0.0004 (0.04%), but less than 0.0012 (0.12%). 2. The metal penetrations of otherwise continuous insulation are isolated or discontinuous (e.g., brick ties or other discontinuous metal attachments, offset brackets supporting shelf angles that allow insulation to go between the shelf angle and the primary portions of the wall structure). No continuous metal elements (e.g., metal studs, z-girts, z-channels, shelf angles) penetrate the otherwise continuous portion of the insulation. 3. Building permit drawings shall contain details showing the locations and dimensions of all the metal penetrations (e.g., brick ties or other discontinuous metal attachments, offset brackets, etc.) of otherwise continuous insulation. In addition, calculations shall be provided showing the ratio of the cross -sectional area of metal penetrations of otherwise continuous Assemblies with C9nCnLU 4U: 1¢'.u]7r100 {'.ea dafinioonJ #lte mote uptim for assemblies with m etal Re Detl3&.05, greater 1h3n 0.04a13 bat less than108" Alternate uptiun EDY assemblies with metal Pe¢e tr A Lions, Brea ter than of equal to 0.084!13 bit Less thsa0.12EA P- 4.5a R-11.9€i R-13ci R-11.4d R-14.3€i 1-15.7€i R-1.336 R-16.6ci R-18.3d R-15.2d R-19.0d R-2ld R-30d R-38d R42d R-38d R-tSd R-53ci R-13+R-7.5d R-13+R-9.4d R-13+R-10.3d R-13 + R-10d R-13 + F. 12.5ci R-13 +R-13.8€i R-13 + R-12.5 c: R-13 + R-15.60 R-13 +R-17.2d R-13 + R-13ci R-13 + R-16.3d R-13 +R-17.9d R-19+R4.5d R-19+R-10.6d R-19+R-11.7d R-19 + R-14€i R-19 + R-17.5ci R-19 +R-19.2d R-19+R-1&i R-19+R-20ci R-19+R-22ci R-20 + R-3.6d R-24 + R4.8d R-20 .+R-53ci R-21 +R-56 R-21 + Rfi.3d R-21 + R-6.4d End of Envelope Requirements Summary 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Project Title: Firdale Village Fire Restoration Date 09/28/2020 Target Insulation Allowance For Building Department Use Fully Conditioned Space - Commercial, Group R, Mixed Use Fenestration Area as % gross above -grade wall area 34.1 % Max. Target: 30.0% Skylight Area as % gross roof area 0.0% Max. Target: 5.0% Vertical Fenestration Alternates: None Selected on ENV -SUM User Note Prescriptive compliance of envelope assemblies may be accomplished by providing insulation R-values per Table C402.1.3 or U-factors / F- factors per Tables C402.1.4 and C402.4. A single project may comply via R-values for some envelope assemblies and U-factors / F-factors for others. U-Facto r/F-Factor Method for Building Component R-Value Method for Prescriptive Compliance Prescriptive Compliance on inuous o Area ot Metal Cavity Ins. Ins. (Cl) Penetrations Assembly Provide plan/detail # of assembly and description R-Value R-Value' in Cl' U-Factor U-Factor Source3 Y O N m O O O L O L_ O U Q Dtl A/A3.0 & A/A3.1 - Ceiling below vented attic R-49 0.027 Table A102.1 0 U) -o m m 0 — � > Dtl A/A3.0 & A/A3.1 R-15 0.076 Table A103.3.1(3) �O Wood -lap siding, PWD sheathing, 2x4 Studs Q 0 O = m o � 0 m O N m c m H — o m U) O (7 @ a Dtl A/A3.0 & A3.1 Existing, E 6" Concrete Basement wall, 2x4 furring studs, existing Assumeedd 0.054 Table A104.1 o insulation and sheetrock o a v m 0 o n a CO o (7 m 0 o 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 Project Title: Firdale Village Fire Restoration Date 09/28/2020 Fenestration Area as % gross above -grade wall area 34.1% Max. Target: 30.0% For Building Department Use Skylight Area as % gross roof area 0.0% Max. Target: 5.0% If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then the project must comply via Component Performance and provide ENV-UA and ENV-SHGC forms. Building Component R-Value Method for U-Facto r/F-Factor Method for Prescriptive Compliance Prescriptive Compliance Perim. Ins. Full Slab Cl Provide plan/detail # of assembly and description R-Value R-Value F-Factor F-Factor Source10 Detail A/A3.0 & A/A3.1 Unheated conc slab. Existing condition. Unknown if 0.730 Table A106.1 insulation was placed below slab when building was m c originally constructed 0 0 a m U 0 m 0 2 Ins. Assembly ,� Provide ID from door schedule and description R-Value U-Factor U Factor Source 0 Door Schedule ID 'V on Sheet A1.0. a Nonmetal Door, 50% Glazed 0.550 Table C303.1.3(1) 0 0 a)U .3 ) 0 m O Q) L O Solar Heat Gain Coefficient (SHGC) U-Factor for Prescriptive Compliance rolec ion Unentation Factor (PF) (N or Assembly Assembly Provide ID from window schedule and description if applicable 12 SEW)13 SHGC14 U-Factor U-Factor Source 14 @ No windows are being replaced 0 0 z 0 0 0 .x w m m c LL a) a U_ 0_ p N (6 C N derri�ath a slab -on -grade or exposed floor, this floor shall be thermally broken from the surrounding floor area with the same amount of insulation as re 0 0- 01 T CO Q Miscellaneous - Refrigerated Spaces Ins. Assembly Provide plan/detail # of assembly and description R-Value U-Factor U-Factor Source �B �- N O O N _O LL LL Cooler / Double Triple Pane Inert Gas Heat Reflective Provide ID from window schedule and description Freezer Pane Glass Glass Filled Treated Glass `o 0 p s= s= N @ O L N Note 1- Insulation that is continuous except for fasteners may be entered here if the cross -sectional area of metal penetration through otherwise continuous insulation is less than 0.12%. Note 2 - Alternate prescriptive continuous insulation R-values per Table C402.1.4, Footnote F may be used if the cross sectional area of metal penetrations exceeds 0.04% but is less than 0.12%. Calculations are required to use these alternate R-values. Note 3 - Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Specify the table number or calculation page number. Note 4 - Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies. Note thermal spacer thickness and R-value in roof assembly description. Note 5 - Intermediate framing is required for prescriptive R-Value compliance in wood -framed wall assemblies. Note 6 - Proposed CMU mass walls in non -Group R that meet Table C402.1.4 Footnote C requirements can enter the target prescriptive U-value of 0.104. Note 7 - Mass transfer slab edges must be covered with an assembly having an overall U-factor of 0.2. Note 8 - Refer to Table C402.1.3, Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. Note 9 - Prescriptive slab -on -grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. Note 10 - Slab -on -grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Note 11 - Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. A door is defined as opaque if less than 50% of the door area has glazing. Note 12 - Refer to Equation C4-6 Projection Factor Calculation. Note 13 - N = Oriented within 45 degrees of true north, SEW = All other orientations. Note 14 - Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or shall be the default value per Section C303.1.3. Note 15 - List all above -grade Group R mass walls and steel frame walls in Group R Walls section. List commercial above grade walls and all other Group R above grade walls in Opaque Walls - Above Grade. Note 16 - Refrigerated Coolers - All cooler roof, wall and door assemblies shall comply with the prescriptive R-values or U-factors per C410. Enter proposed information under the most similar assembly type. Slab edge insulation for slab -on -grade floors shall comply with C402. Floors that separate a cooler from a non -cooler space (unconditioned and conditioned) shall be insulated per C402. Vertical fenestration (not within cooler doors) shall comply with the prescriptive R-values or U-factors per C402. Enter only the opaque portion of refrigerated space doors. Windows within doors and reach -in display case doors shall comply with C410 prescriptive requirements. Note 17 - Refrigerated Freezers - All freezer roof, wall and door assemblies shall comply with the prescriptive R-values or U-factors per C410. Enter proposed information under the most similar assembly type. Freezer floor insulation shall comply with C410. Insulation is required under the entire freezer floor. If the freezer floor assembly rests on top of a standard floor, the vertical edge of the freezer floor shall be entered as and comply with the requirements for a freezer wall. If freezer floor insulation is installed as integral to or applied underneath a slab -on -grade or exposed floor, this floor shall be thermally broken from the surrounding floor area with the same amount of insulation as required for a