BLD2020-0999+Interior_Lighting_Summary+9.28.2020_8.50.58_AM2015 Washington State Enerciv Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Info
Project Title: Firdale Village Fire Restoration -Unit 9627
Date 7/16/2020
Compliance
Applicant Information. Provide contact information for individual Mo can
For Building Department Use
forms do not
respond to inquiries about compliance form information provided.
Company Name: BC Investigative Engineers
require a
password to
Company Address: 3605 C St NE, Auburn, WA 98002
use.
Instructional and
Applicant Name: Jesse Binford
calculating cells
are write -
Applicant Phone: 253-833-5557
protected.
Applicant Email: jbinford@bcie.net
Project Description
0 New Building QAddition Alteration 0 No Lighting Scope
Include PROJ-SUM form (included in envelope forms workbook) meth lighting compliance forms.
Interior Lighting System
Description
0 Interior Lighting Plans Included
Interior Lighting Power
0 Building Area Method 0 Space -by -space Method
Allowance Method
Select method used in project.
Interior Lighting Controls
0 All C405.2.1- C405.2.8 Lighting Controls [3C405.2 Exception 5 Luminaire Level
Lighting Controls (LLLC)
0 Additional Efficiency Package Option
C406.4 Enhanced Digital Lighting
To comply meth C406.4, no less than 90% of the total installed interior lighting poorer shall comply meth
required controls per C406.4.
Dwelling Unit Interior
Permanently installed interior lighting fixtures in dwelling units comply with: No Dwelling
Lighting
Units
O C405.2 thru C405.5 Commercial Lighting Controls and LPA
0 C406.3 High Efficacy Lighting
0R404.1 Residential High Efficacy Lighting. Dwelling unit lighting compliesweth WSECResidential
provisions in lieu of WSEC Commercial provisions.
Exterior Lighting System
Description
0 Exterior Lighting Plans Included
Building Additions
Compliance Method Interior lighting Exterior lighting
............................................................................................................
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
Refer to Section C502.2.6 for additional
requirements.
............................................................................................................
Lighting systems in addition are combined with existing
building lighting systems to demonstrate compliance
.........................................................................................................................................................................................................................................................................
Addition is combined with existing:
For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in
Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form.
For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wettage in
Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form.
2015 Washington State Enerav Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Firdale Village Fire Restoration - Unit 9627
Date 7/16/2020
Change of Space Use
0 Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage
table in LTG-INT-BLD or L TG-INT-SPA CE form.
Interior and Exterior
Lighting Power
Interior lighting
Parking garage
Exterior lighting
Lighting Alterations
..............:................
50% or more of existing are replaced
0
0
....... ........................ ............
0
Select all Lighting Power and Lighting
Control elements that apply to the scope
Less than 50% of existing are replaced
0
0
0
of the retrofit project. If project includes a
Lamp and/or ballast replacement only
0 0
combination of spaces where less than
50% of the existing fixtures are replaced
— existing total wattage not increased
in some spaces, and 50% or more of the
fixtures are replaced in others, then
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with
provide separate lighting power
total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in
compliance forms for the two retrofit
Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
conditions. Spaces undergoing the same
Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed
type of retrofit may be combined into one
the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed
lighting power compliance form.
Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50% threshold applies to numberof luminaires for interior spaces and parking garages, and total
Refer to Section C503.6 for additional
installed wattage for exterior luminaires.
requirements.
Lighting Controls
Interior lighting
Parking garage
Exterior lighting
All alteration lighting controls shall be
New wiring installed to serve added
commissioned perC408.3.
fixtures and/or fixtures relocated to
0
0
0
new circuit(s)
New or moved lighting panel
0
0
0
......... ................
Interior space is reconfigured
luminaires unchanged or relocated
_...................................
......................................................................................... ............................... ................... ................. ........... ........................ -
Newwiring orcircuit - For interior lighting, provide required manual controls perC405.2.3,
occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application
No changes are being made to
specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
the interior or exterior lighting
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic
systems and existing space
time switch controls per C405.2.2.
uses and configuration are not
Reconfigured interior space - Provide all required lighting controls that apply to a new interior
changed.
space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 20l7
Project Title:
Firdale Village Fire Restoration - Unit 9627
Date
7/16/2020
Calculation
Area NOTE 9
0 New Construction 0 Addition -
Q Spaces where < 50% of Q Spaces where >_ 50% of
0 Addition
0 Spaces where the Use
For Building Department
Use
LPA
Calculation
Type
40 Standard O Additional Efficiency Package Option
C406.3 Reduced Interior Lighting
To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA.
Refer to C406.3 for additional requirements.
User Note
Only spaces with
lighting changes
Maximum Allowed Lighting Wattage NOTE I
Location (plan #,
room #)
Space Type
Ceiling
Height""
Gross Interior
,area in ft2
Allowed
Watts per ft2
Watts Allowed
(watts/ft2 x area)
Unit 9627: Hallway
Corridor: all other
8.9
99
0.530
52
Unit 9627: Office:
Al.1
Office: Enclosed
8.9
258
0.890
230
Unit 9627:
Restroom: Al.1
Restroom: all other
8.9
23
0.780
18
Unit 9627 Storage
Al.1
Storage room
7.75
187
0.500
94
Unit 9627 Unisex
Restroom - Al .1
restroom: all other
7.75
56
0.780
44
Unit 9627 Unisex
ADA Restroom
restroom: all other
7.75
73
0.780
57
Unit 9627 -
Restroom Al.1
Restroom: all other
7.75
22
0.780
17
Total Area 718
Retail Display Allowance from LTG-INT-DISPLAY
Lobby Art/ExhibitDisplay Allowance from LTG-INT-DISPLAYNOTEs� Allowed Watts
512
Proposed Lighting Wattage NOTES
Location (plan #,
room #)
Fixture Description NOTE 4, 5, 6
Number of
Fixtures
Watts/
Fixture NOTE 7
Watts
Proposed
Unit 9627: Hallway:
A2.0
A21 Light Bulb
1
23
23
Unit 9627: Office:
A2.0
1 Tube Fluorescent, Lamp T8 4 Feet
1
32
32
Unit 9627:
Restroom: A2.0
A21 Light Bulb - Existing
2
32
64
Unit 9627 Storage:
A1.1
1 Tube Fluorescent, Lamp T8 4 Feet
3
32
96
Unit 9627 Unisex
Restroom: Al.1
A21 Light Bulb
3
23
69
Unit 9627 Unisex
ADA Restroom:
A1.1
1 Tube Fluorescent, Lamp T8 4 Feet
1
32
32
Unit 9627
Restroom: Al.1
A21 Light Bulb
2
23
46
Proposed Retail Display Lighting from LTG-INT-DISPLAYI
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Waftsl 362
Interior Lighting Power Allowance COMPLIES
Note 1 - List all unique space types per Table C405.4.2(2) that occurin the project scope. Select space type category from drop down menu.
Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f.
Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included).
For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as
existing
in fixture description.
Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp mettage). For low
voltage
lighting, enter the wattage of the transformer. For line voltage track/busmey systems, enter the larger of the attached luminaire wattage or
50
wettsAineal foot, or enter the wattage limit of permanent current limiting device.
Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display
fixtures in LTG-INT-DISPLAY form only.
Note 9 - Calculation Area Details:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building
lighting systems to demonstrate compliance. Refer to C502.1.
b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If
building addition W11 comply as combined with the overall existing building lighting systems, include all applicable existing Space Types
and aross interior areas.