Loading...
APPROVED STM RESUB1 BLD2022-0746+Storm_Drainage_Report+10.6.2022_2.10.26_PM+3150892RAM Engineering BLD2022-0746 Memorandum To: City of Edmonds RESU B Date: June 6, 2022 Engineering Division Oct 06 2022 Updated: October 6, 2022 From: Rob Long, PE DE EILO MF NDTSOERVCES DEPARTMENT RAM Engineering Subject: Select Homes Lot 2- 8929 220th St SW Short Plat Stormwater Memo RAM Job No. 20-016 This memo provides a summary of the stormwater drainage control system for Lot 2 of the 8929 220th St SW Short Plat (PLN 2021-038). A site -specific geotechnical evaluation recommends one stormwater BMP for the site; BMP T5.13: Post -Construction Soil Quality and Depth based on the site's soil conditions. In accordance with Edmonds Code, lawn and landscape areas will be managed by post -construction soil quality and depth (soil amendments). The roof top, driveway, walk and patio areas will be managed by a detention pipe designed in accordance with the Edmonds Stormwater Addendum. Additionally, a 10 ft (min.) footing drain drywell trench shall be installed with the house construction to disperse footing drain water. The footing drain drywell trench shall be installed and evaluated during construction by the geotechnical engineer. The Lot 2 roof, driveway, walk and patio of 4,302 sf hard surface will require 35 ft of 36" pipe (4,302 sf x 0.008) for BMP mitigation. The detention pipe will be constructed under the driveway area east of the proposed house as part of the short plat site improvements. Below is a stormwater control summary table for Lot 2: Stormwater Control Summary: Project Site Category: Category 2 (part of the 8929 2201h St SW 2-Lot Short Plat) Discharge Location: City's Municipal Separate Storm Sewer System (MS4) Type of Area Square Footage Storm water Facility Lawn and Landscape 4,729 sf Soil Amendments (BMP T5.13) 8,519 sf Tree Retention Area Roof 2,617 sf Detention Pipe (ECDC 18.30.030.D.5.d) 35 ft of 36" pipe (4,302 sf x 0.008) Hard Surfaces 1,225 sf Detention Pipe (ECDC 18.30.030.D.5.d) (Driveway/Apron, Walk and Patio) 26 ft of 24" pipe (4,302 sf x 0.008) 25% Retrofit 0 SF None P M Engineering 19109 36" Ave W, Suite 100 Lynnwood WA 98036 (425) 678-6960 RAMengineeringinc.com Select Homes Lot 2- 8929 2001h ST SW Short Plat Lot 2 Stormwater Memo RAM Job No. 20-016 Select Homes 220th St SW Short Plat Lot 2 Hard Surface Summary: Roof = 2,617 sf Driveway = 1,175 sf Sidewalk/Patio = 50 sf Total = 4,302 sf I I 1 I I I 1 I I I� l 1 F 7 a ; /// q-_ LJ N am r— O 2 I I 6 110• LENGTH FO TING 1 ti F-DRAIN DR LL 7RINCH (PER GEOM-CH REL10 MEN�ONJ I r Y ROOFDRAIN 4" PVC F007ING I 0 1109 MIN DRAIN ® 1.OX MIN Roof = 2,617 SF SDCO3r.i i - _ COVERED PORCH PROPOSED HOUSE ='I i do AIN FF 434.70- RETAINING WALL TO BECONSTRUCFED - AS RT OF SHOR THE 20JRD ST SW } PLAT (PLN2021-0038) i I G�RAGE , •__� FFL434. r 4" PVC SEWER SERVICE ® 2.0% MIN CONNECTED TO SEWER STUB IE 4Ja7t !F 413T.7f BSBL In ,' MB9'28'18"W BB.59• D6Y U77LI77ES I Ir I � I � AA Page 2 of 3 October 6, 2022 jr WALK= 50 SF CONNECT TO STUB V�STQRM IF 4,31,1t 5• ��ti 1NSTilLL 1-1/2" PE (160 PSI) FROM WATER METER TO HOUSE DETAILS. (TRACER WIRE TO 6E �i INSTALLED WITH WATER LINE) SLOPE DRIVEWAY TO CHANNEL DRAIN ,---(SEE SHEET 7P-01) CHANNEL DRAIN TOP 434.35 NOS PRO CHANNEL DRAIN OR APPROVED EQUAL (SEE DETAIL ON SHT GN--01) DRIVEWAY = 1,175 SF — - i I , r -41ORT PLAT IMPROVEMENTS Tp BE CONSTRUCTED AS i PART OF 77-IE 2207H ST SW SIORT PLAT (PLNm21-oam) RAM ^ngineering 1910936`1Ave W,Suite 100 Lynnwood WA 98036 (425)678-6960 RAMengineeringinc.com Select Homes Lot 2- 8929 2001h ST SW Short Plot Lot 2 Stormwater Memo RAM lob No. 20-016 SOLID LOCKING LID EL. 435.Of EMER OF 431.69 6" PVC RESTRICTOR 6" PVC !E 428.50 1 ' MIN CS 48" - TYPE II SOLID LOCKING LID EL. 434.50t 35 -36" CPEP ® 0.5OX MIN DETEN710N TANK 2'-8" CPEP STUB CONNEC77ON ® 0.5% PVC CAP ON 607TOM WI7H 0.5" ORIFICE (SEE COAINEC77ON & CONTROL DEVICE DETAIL THIS SHEET) Page 3 of 3 October 6, 2022 8"IE 431.02 CB TYPEI LOT 2 - DETENTION SYSTEM DETAIL NOT TO SCALE DETENTION SYSTEM SIZING 36" DE7EN77ON PIPE REQUIRED 4, 302 X 0.008 = 34.42LF REQ'D (35LF 36" PIPE PROPOSED) (PER EDMONDS STORM WATER ADDENDUM 6.3.1) x � 36508'$ ZONAL 1016/ZOZZ /_1,U:Z91TjaIK p. p JoAnne Zu(au{, rEM Tech 2123123 Stormwater Engineer Date Taylor Brown, PE Blueline Group Complies with City of Edmonds Stormwater Code RAM Engineering 1910936 th Ave W, Suite 100 Lynnwood WA 98036 (425)678-6960 RAMengineeringinc.com