FIR2024-0023+Fire_Alarm_Equipment_Specification_Sheets+3.4.2024_6.44.37_PM+4102412Victory Tavern T.I. Fire Alarm Submittals w EL CONSULTING SERVICES SAFE consulting services 1800 Bickford Ave. Suite #214 Snohomish, WA 98290 Voice (800) 742-8960 Fax (206) 363 -3291 E-Mail spokaneoffice@safeconsulting.biz Bookmark Summary COVER PAGE Page 1 EXISTING POTTER IPA-4000 Page 2 POTTER PAD100-SIM Page 6 POTTER HS-24WR-WP Page 8 POTTER CS/CHS SERIES Page 12 3/2/2024 (E)POTTER The Symbol of Protection Features • 4,064 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 1500 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 10 Amp Power Supply, Expandable to 315 amps • 6 NACS, Regulated, Rated at 3 Amps each, expandable to 192 • 4 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Cabinet will house up to 18 AH batteries • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information • Product includes 5 year warranty • UUKL Listed for Smoke Control Description The IPA4000 is an expandable analog/addressable releasing fire alarm system with a total system capacity of 4,064 addresses. Additional capacity on the system is achieved using multi -point SLC modules The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. The system is expandable with a total of thirty-one additional addressable Signaling Line Circuits (SLC) each with a maximum of 127 devices. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA-4000 has a 10 Amp power supply with six Notification Appliance Circuits (NACs) and four Input/Output (1/0) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA4000 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA4000 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six PAD100-SLCE SLC loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. IPA-4000 Fire Alarm Control Panel FM APPROVED Technical Specifications ge LISTED Dimensions 18 "/16"W x 27 s/16"H x 4 7/16"D AC Mains 5.0 Amps @ 120 VAC 50/60 HZ 3.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-220 mA • 10 Amps power for NACs, I/O, and P-Link Battey 3 Amps per NAC, regulated • 1 Amp per I/O circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp Temperature and 320 to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 1 OF 4 (E)POTTER The Symbol of Protection IPA-4000 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 4,064 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD 100-PHD Combination Analog Photo Electric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135' Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135' F to 185°F. PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-I13 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD 100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OR0I One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 2 OF 4 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps."Each loop is capable of 127 points, with a max wiring distance of 10,000 ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-4000 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module (maximum of 31 per IPA-4000) IPA-4000 Fire Alarm Control Panel RA-6075R — 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) — 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) — 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-4000 as releasing circuits. CA-6500 — Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 — UL listed, Dual line telephone alarm communicator DRV 50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 — Fiber interface module, used to extend P-Link to multi - mode fiber (2 required) RLY 5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi -Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 — Initiating device circuit provides 6 programmable inputs AE-2 — Two card expansion cabinet AE-8 — Eight card expansion cabinet AE-14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-4000 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 3 OF 4 (E)POTTER The Symbol of Protection Dimensions 18.91 " 17.60" TOP o ° O Oo 0 0 0 0 N LEFT SIDE BOTTOM Ordering Information Model Description Stock No. IPA-4000 Fire Alarm Releasing Control Panel 3992717 Replacement Board IPA-4000 3992740 IPA-4000 Fire Alarm Control Panel 4.41" 3.75" DEPTH SIDE Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVNOCI12CZ 73212BN4TNLVN0C322C2 Victaulic 753-E Series Mini Max MX123 & MX200 w/ 8876677 & 889323 Viking 11591, 11601, 11602, 13843, & 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 4 OF 4 (E)POTTER The Symbol of Protection Features • One (1) Class B monitoring input • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. Description The PAD100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD100-SIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The PAD100-SIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD 100-SIM Single Input Module P�SEMB��O i4, rHE J © POTrEIt ��U`<APP�ROV>ED FR.. Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Max Wiring Resistance 10012 of IDC Max Wiring INF Capacitance of IDC EOL Resistor 5.1K f2 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (I06mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830083 - REV D 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 K A Wiring Diagram PAD100-SIM With Class B Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR 5.1KOHM % W Part #3005013 al Ordering Information Model Description Stock No. PAD100-SIM Single Input Module 3992704 PAD 100-SIM Single Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830083 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER ® The Symbol of Protection Features • Fixed 75cd strobe • Includes the WPBB surface -mount (standard) or WPLPBB Low Profile (LP) enclosure • WPBB/LP made of clear Lexan® - provides maximum visibility and reliability, allowing full 75cd output • Super -Slide® Bracket — Ease of supervision testing • Checkmate® - Instant voltage verification • Synchronize strobe and/or horn with AVSM module • Switch selection for high/low dBA • Switch for chime, whoop, mechanical, and 2400Hz tone • Input terminals accept 18 to 12 AWG • Switch for continuous or temporal 3 tone (not available on whoop) • Tamperproof re-entrant grill • 5 year warranty Application The S/HS-WP Series Outdoor Signals are wall mount, low profile strobes and hom/strobes that offer dependable audible and visual alarms for warning and emergency notification in outdoor locations. Description The S/HS-WP Series Outdoor Signals are 24VDC strobes and horn/ strobes equipped with a fixed 75 candela strobe. This series of outdoor signals are available in two different versions. The standard version includes a surface -mount back box (WPBB) to install directly on a wall. The Low Profile (LP) versions includes a low profile back box (WPLPBB) designed to be installed on a flush - mounted electrical box. The weatherproof enclosure is made of clear Lexan® which provides maximum visibility and reliability for effective visible signaling, allowing full 75cd output. The S/HS-WP series strobe has a minimal operating current and a minimum flash rate of 1Hz regardless of input voltage. The strobe is synchronized using Gentex sync. protocol or the AV SM Sync. Module. The S/HS-WP Series is equipped with a universal 4" mounting bracket which incorporates the popular Super -Slide® feature that allows the installer to easily pre -wire the system and test for supervision. The product also features a locking mechanism that secures the signal to the bracket without showing any screws and the Checkmate® - Instant Voltage Verification Feature which allows the installer to check the voltage drop, current draw, and match against the blue print. S/HS-WP Series Outdoor Strobes and Horn/Strobes LP Version Standard WGNAUxs UL LISTED S3247 Product Listings • ANSI/UL 464 and 1638 • Complies with American with Disabilities Act (ADA) • Complies with IBC / IFC / IRC Technical Specifications Operating Voltage I Nominal 24VDC (16-33VDC) Operating -31°17 - 150°F (-35° - 66°C) Temperature LP Version - 5.75" H x 4.75" W x 3.25" D Dimensions Standard - 5.75" H x 4.75" W x 4.18"D Wiring Connections Terminals accept 18 - 12 AWG LP Version — Single gang, double gang, or 4" square back box Mounting Standard Version - Surface mount back box included Shipping Weight 2.05 lbs. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 1 OF 4 (E)POTTER The Symbol of Protection S-24-WP, 75 Candela, Outdoor Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color WP Enclosure S-24WR-WP 4890050 Red Standard S-24WW-WP 4890051 Off -White Standard S-24PWR-WP 4890052 Red -Plain Standard S-24PWW-WP 4890053 Off -White -Plain Standard SLP-24WR-WP 4890054 Red Low Profile SLP-24WW-WP 4890055 Off -White Low Profile SLP-24PWR-WP 4890056 Red -Plain Low Profile SLP-24PWW-WP 1 4890057 1 Off -White -Plain Low Profile S/HS-WP Series Outdoor Strobes and Horn/Strobes Model Designations "W" = Wall Mount "R" = Red Face Plate "W"=Off- White Face Plate "P"= Plain (Note: Plain units are non -returnable) "LP"= Low Profile (WPLPBB Enclosure) Strobe Current Ratings Candela 75 cd 24 VDC 112 mA UL Max 170 mA NOTE: Forunfiltered FWRratings, see installation manual. HS-24-WP Series, 75 Candela, Outdoor Horn /Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color Reverberant dBA at 10', per ANSVUL 464 In Anechoic Room dBA at 10' WP Enclosure HS-24WR-WP 4890060 Red 70-82 100 Standard HS-24WW-WP 4890061 Off -White 70-82 100 Standard HS-24PWR-WP 4890062 Red -Plain 70-82 100 I Standard HS-24PWW-WP 4890063 Off -White -Plain 70-82 100 Standard HSLP-24WR 4890064 Red 70-82 100 Low Profile HSLP-24WW 4890065 Off -White 70-82 100 I Low Profile HSLP-24PWR 4890066 Red -Plain 70-82 100 Low Profile HSLP-24PWW 4890067 Off -White -Plain 70-82 100 Low Profile Horn Decibel and Current Ratings Horn Setting Minimum dBA at 10', Per UL 464 (HIGH) Minimum dBA at 10', Per UL 464 (LOW) Regulated 24VDC Max. Operating Current, at High Setting (mA) Temporal 3 2400Hz 78 71 * I 28 Temporal 3 Mechanical 76 70* I 25 Temporal 3 Chime 70* 66* 15 Continuous 2400Hz 81 74* I 28 Continuous Mechanical 80 72* I 25 Continuous Chime 1 70* 66* 15 Whoop 1 82 1 69* 56 *Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 2 OF 4 (E)POTTER The Symbol of Protection Tone Switch Locations Tone Switch Position 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical - Continuous OFF ON ON 2400Hz - Temporal 3 ON OFF ON 2400Hz - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Chime - Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF I OFF OFF NOTES. • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Super Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in -place installation. tip Mounting Outdoor Enclosure Super Slide® Mounting Plate: Mounts to WPBB Outdoor Enclosure S/HS-WP Series Outdoor Strobes and Horn/Strobes S¢ S¢ S_ H+ H_ ate® Instant Voltage ion necessary to confirm the voltage ig the line of devices. The access provided in the back of the block to allow the voltage to fired directly without removing e. Typically, this would be done d of the line to confirm design ✓lost measurements will be taken S+ and S- locations although provided to other locations. Care should be taken to not short the test probes. Super Slide® Mounting Plate: Mounts to WLPBB Outdoor Enclosure Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 3 OF 4 (E)POTTER The Symbol of Protection UL Listed Centr0I - Signal - Signal Panel ' R y S/HS-WP Series Outdoor Strobes and Horn/Strobes Wiring Diagrams 1 RUM �I UL Listed Control Signal Signal Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised Signal Circuit \+ END OF LINE END OF LINE RESISTOR RESISTOR END OF LINE RESISTOR NOTES. • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. Architect and Engineering Specifications The audible and/or visible signal shall be Potter S/HS-WP Outdoor Series or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSF UL 1638 and/orANSFUL 464. The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 112mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela requirements of the ADA (75cd). The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. The appliance has extended temperature range of -31° to 150°F (-35° to 66' Q. The appliance shall satisfy virtually all outdoor and severe environment applications. The WPBB enclosure includes a gasket that must be inserted between the box and mounting bracket. There are drain holes in the back box to allow for drainage, the seal on the WPBB enclosure is not water tight. The WPLPBB enclosure includes a weather seal for mounting to wall and intended for use with universal electrical box. To allow for drainage, bottom edge of enclosure is not water tight. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008 1 DESIGNING, MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830057 - REV B • 3/15 PAGE 4 OF 4 c POTTER The Symbol of Protection U� LISTED S3247 Product includes a 5 year warranty Description The Potter CS/CHS Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The CS/CHS offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The CHS horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone. All tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the temporal three alarm mode. The CS Series has a very minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. CS/CHS SELECTABLE CANDELA CEILING MOUNT Features • Nominal voltage 24 VDC • Tamperproof field selectable candela options 15, 30, 75, 95, 115, & 150 • Super -Slide® Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input Terminals 12 to 18 AWG • Switch Selection for High or Low dBA • Switch Selection for 2400Hz or mechanical Tone • Switch Selection for Continuous or Temporal 3 • Tamperproof re-entrant grill • Surface mount with the CLNGBB (Ceiling Surface Mount Back Box) • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature: • 32°F to 120°F (0°C to 49°C). The CS Series is not listed for outdoor use. Unit Dimensions • 6" (15.24 cm) x 2.6" (6.604 cm) The Ceiling Mount Series comes standard with the 4" mounting plate which incorporates the popular Super -Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The CS/CHS also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw without removing the signal. The CS Series appliances are ANSI/UL 464 and ANSUUL 1971 listed for use with fire protective systems. PotterElectric Signal Company, LLC • St. Louis, MO 63042 USA- CustService: 866-572-3005 •TechSupport: 866-956-0988 • Canada888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830051 -REV A PAGE 1 OF 4 06/13 CF POTTER The Symbol of Protection Mounting Super -Slide® 1. Slide Onto Bracket Checkmate® Instant Voltage Verification DO NOT PAINT CD C�j o o O n z C ��6 0 � ®lSfn94C��§ The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTICE: CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. CS/CHS SELECTABLE CANDELA CEILING MOUNT 3. Snap Cover Over Assembly Switch Locations FAF' Switch positions 1 and 2 in the down position to select isolated horn and strobe power inputs. Switch 3 selects between temporal or non - temporal tone. Up is temporal. Switch 4 selects between mechanical or high frequency tone. Up is mechanical. Switch 5 selects between high or low dBA. Up is high dBA. PotterElectric Signal Company, LLC • St. Louis, MO 63042 USA- CustService: 866-572-3005 -Tech Support: 866-956-0988 • Canada888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830051 -REV A PAGE 2 OF 4 06/13 CS/CHS CP� POTTER SELECTABLE CANDELA The Symbol of Protection CEILING MOUNT CS Series 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela CS-24R 4890020 24 VDC 15, 30, 75, 95, 115, 150 CS-24W 4890021 24 VDC 15, 30, 75, 95, 115, 150 CS-24PR 4890022 24 VDC 15, 30, 75, 95,115, 150 CS-24PW 4890023 1 24 VDC 15, 30, 75, 95, 115, 150 CHS Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA @ 10 ft. per ANSI/UL 464 In Anechoic Room dBA @ 10 ft. CHS-24R 4890040 24 VDC 15, 30, 75, 95, 115, 150 81-86 90 CHS-24W 4890041 24 VDC 15, 30, 75, 95, 115, 150 81-86 I 90 CHS-24PR 4890042 24 VDC 15, 30, 75, 95, 115, 150 1 81-86 I 90 CHS-24PW 4890043 24 VDC 15, 30, 75, 95, 115, 150 1 81-86 1 90 Model Designations: C = Ceiling Mount S = Strobe HS = Horn/Strobe R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. CS24 Product Strobe Current Ratings (mA) Candela 15 cd 30 cd 75 cd 95 cd 115 cd 150 cd 24 VDC (16-33 Volts) 24 VDC 72 mA 101 mA 167 mA 200 mA 214 mA 286 mA UL Maxl 120 mA 120 mA 200 mA 220 mA 290 mA 1 321 mA CHS24 Product Horn Decibel and Current Ratings (mA) Horn Mode Minimum dBA @ 10 ft. per ANSWL 464 (HIGH) Minimum dBA @ 10 ft. per ANSI/UL 464 (LOW) Regulated 24 VDC Max. Operating @ High Setting (mA) Temp 3 2400Hz 83 75 23 Temp 3 Mechanical I 81 I 73* 22 Continuous 240011z I 86 I 78 I 23 Continuous Mechanical 84 76 22 NOTES: • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSWL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). • RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. PotterElectric Signal Company, LLC • St. Louis, MO 63042 USA- CustService: 866-572-3005 -Tech Support: 866-956-0988 • Canada888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830051 -REV A PAGE 3 OF 4 06/13 CF POTTER The Symbol of Protection Architect & Engineering Specifications CS/CHS SELECTABLE CANDELA CEILING MOUNT The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC. The notification appliance shall also be listed with the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Conventional CS/CHS Series Wiring Diagrams UL Listed Control Signal Panel S+ S+ S- H+ H- Supervised 0 0 Signal Circuit n UL Listed Control Signal Panel S+ S+ S- H+ H- Supervised 0 Signal Circuit END LINE RESISTOR \ � Signal I I Signal END OF LINE RESISTOR END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.12ottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company, LLC • St. Louis, MO 63042 USA- CustService: 866-572-3005 -Tech Support: 866-956-0988 • Canada888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830051 -REV A PAGE 4 OF 4 06/13