Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2024-0017+Fire_Sprinkler_Equipment_Specification_Sheets+2.22.2024_8.28.15_AM+4075092
Columbia Fire SPRINKLE! SYSTEM S02V:Cf • 111IAII WA CL# COLUMF952MG MATERIAL SUBMITTAL DRY PIPE AUTOMATIC FIRE SPRINKLER SYSTEM SPEC SECTION: 2113 16 ALTERNATIVE LEARNING CENTER 7600 272ND STREET NW STANWOOD WA 98292 Authority Having Jurisdiction City of Stanwood McGranahan Architects 2111 Pacific Ave #100 Tacoma WA 98402 (253) 383-3084 Columbia Fire Inc. 111 S Findlay Street Seattle WA 98108 Phone: (206) 232-8569 Project Number: 1903134 By: Li G. Li Table of Content DRY PIPE AUTOMATIC FIRE SPRINKLER SYSTEM SPEC SECTION: 2113 16 1. PIPING 2. FITTINGS / COUPLINGS 3. SPRINKLER HEADS AND ACCESSORIES 4. VALVES 5. ELECTRICAL / FIRE ALARM COMPONENTS 6. PIPE HANGERS 7. SEISMIC BRACING COMPONENTS 8. ACCESS DOORS 9. MISCELLANEOUS EQUIPMENT 1. PIPING DRY PIPE AUTOMATIC FIRE SPRINKLER SYSTEM SPEC SECTION: 2113 16 FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL" and C-UL Listed. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10, 1-8 NPS) • ASTM A795, Type E, Grade A (Schedule 40, 1-2 NPS) • ASTM A53, Type E, Grade B (Schedule 40, 2-8 NPS) • ASTM A53, Type F, Grade A (Schedule 40, 1-4 NPS) • NFPA 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. PROJECT: ENGINEER LOCATIONS: ❑ BLACK 700 South Dock Street info@wheatland.com — Sharon, PA 16146 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @WheatlandTube CONTRACTOR: Finishes and Coatings All Wheatland black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black or hot -dip galvanized, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. SPECIFICATION REFERENCE: COMMENTS: ❑ HOT -DIP GALVANIZED DATE: SYSTEM TYPE: 4rWheatland Tube A DIVISION OF ZEKELMAN INDUSTRIES SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H2O FILLED PCS./LIFT 21' 24' 25' UL '"IM_ in. mm in. mm Ibs. Ibs. 1 Ibs. Ibs. Ibs. CRR* 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1% 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 11/z 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 21/z 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 2.1 SCHEDULE 40 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H2O FILLED PCS./LIFT 21' 24' 25' VL iim- in. mm M_F'IjbE_' 'jr".�rffiW CRR* 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 11/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 11/z 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 21/z 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3Yz 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8** 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 8 NPS Schedule 40 is FM Approved but not UL Listed. UL C UL F M APPROVED 700 South Dock Street info@wheatland.com WFS-081619 ��11 - Sharon, PA 16146 wheatland.com Wheatland Tube P 800.257.8182 Follow us On Twitter: igflpa A DIVISION OF ZEKELMAN INDUSTRIES F 724.346.7260 @WheatlandTube 2. FITTINGS /COUPLINGS DRY PIPE AUTOMATIC FIRE SPRINKLER SYSTEM SPEC SECTION: 2113 16 90° Elbow (Class 150 Standard) Fig.1101 I@ us LISTED APPR O ASC / Engineered Solutions ASC Engineered SolutionsTM offers the broadest line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASC's strict quality standards. ALL Anvil Class 150 Malleable Iron Fittings conform to ASME B16.3 and unions conform to ASME B16.39. ALL elbows and tees s/s" (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered SolutionsT11 Representative. See following page for standards and specifications. Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. All elbows and tees %" (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings Pressure -Temperature Ratings Pressure - Temperature Ratings Pressure Pressure Class 300 Temperature Temperature Class sizes Sizes Sizes Class 150 Class 250 Class 300 150 'i+°-1.1 11i "-2" 21/z'-T' (6-25mm) (32-51 mm) (64-76mm) °F/°C PSI/bar PSI/bar PSI/bar F/°C PSI/bar PSI/bar PSI/bar PSI/bar -20°-150° 300 500 600 -20°-150° 300 2000 1500 1000 -28.9°-65.6° 20.7 34.5 41.4 -28.9°-65.6° 20.7 137.9 103.4 68.9 200° 265 455 550 200° 265 1785 1350 910 93.3° 18.3 31.4 37.9 93.3° 18.3 123.1 93.1 62.7 250° 225 405 505 250° 225 1575 1200 825 121.1 ° 15.5 27.9 34.8 121.1 ° 15.5 108.6 82.7 56.9 300° 185 360 460 300° 185 1360 1050 735 148.9° 12.8 24.8 31.7 148.9° 12.8 93.8 72.4 50.7 350° 150 315 415 350° 150 1150 900 650 176.7° 10.3 21.7 28.6 176.7° 10.3 79.3 62.1 44.8 400° 110 270 370 400° - 935 750 560 204.4° 7.6 18.6 25.5 204.4° - 64.5 51.7 38.6 450° 75 225 325 450° - 725 600 475 232.2° 5.2 15.5 22.4 232.2° - 50.0 41.4 32.8 500° 260.0° - - 180 12.4 280 19.3 500° 260.0° - - 510 35.2 450 31.0 385 26.5 ANVIL. 550° - 130 230 550° - 300 300 300 287.8° - 9.0 15.9 287.8° - 20.7 20.7 20.7 - An ASC Engineered Solution Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F. PROJECT INFORMATION APPROVAL STAMP Project: ❑ Approved ❑ Approved as noted Address: Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PS-11.16 page 1 Ps-sue-1101-vo120211110 ppppp� ASC / Engineered Solutions 90° Elbow (Class 150 Standard) Fig.1101 A, N Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/13N 20 ASME 1316.3 ASTM Al97 ASTM Al53 ASME B1 20.1 ASME B16.3 Class 300/PN 50 ASME 1316.3 ASTM Al97 ASTM Al53 ASME 131 20.1 ASME 1316.3 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 1316.39 ASTM Al97 ASTM Al53 ASME 131 20.1 ASME 1316.39 Class 250 ASME B16.39 ASTM Al97 ASTM Al53 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME 1316.39 ASTM Al97 ASTM Al53 ASME 131 20.1 ASME 1316.39 Note: ASTM B633. Type I, SC 4, maybe supplied as alternate zinc coating per applicable ASME B16 product standard ®©o asc-es.com Building connections that Last" PS-11.16 page 2 PS-SUB-1101-v0120211110 V,ASC `114zp Engineered Solutions 900 Elbow (Class 150 Standard) Fig.1101 Size A Black Unit Weight Galvanized Size A Black Unit Weight Galvanized NPS/DN In./mm Lbs./kg Lbs./kg NPS/DN In./mm Lbs./kg Lbs./kg 1/8 11/16 0.06 0.06 11/2 115/16 1.30 1.30 6 17 0.03 0.03 40 49 0.59 0.59 1/4 13/16 0.11 0.11 2 21/4 2.06 2.06 8 22 0.05 0.05 50 57 0.93 0.93 % 16/16 0.17 0.17 21/2 211/16 3.55 3.55 10 24 0.08 0.08 65 68 1.61 1.61 1/2 11/8 0.30 0.30 3 31/16 5.46 5.46 15 29 0.14 0.14 80 78 2.48 2.48 3/4 1 V16 0.45 0.45 31/2 37/16 7.10 7.10 20 33 0.20 0.20 90 87 3.22 3.22 1 11/2 0.73 0.73 4 313/16 8.95 8.95 25 38 0.33 0.33 100 98 4.06 4.06 11/4 13/4 0.97 0.97 5 41/2 13.90 13.90 44 0.44 0.44 125 114 6.30 6.30 6 51/s 23.00 23.00 Note: 150 130 10.43 10.43 See first page for pressure -temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SolutionsTM' Representative ifyou need verification All elbows and tees 3/s" (10 DN) and larger are 100% gas tested at a minimum of100 PSI (6.9 bar). ®©o asc-es.com Building connections that Last" PS-06.13 page 3 PS-SUB-1101-v0120211110 e 's Ir ) ASC. / Engineered Solutions Fig. 1101 900 Elbow (Class 150 Standard) General Assembly of Threaded Fittings Inspect both male and female components prior to assembly. • Threads should be free from mechanical damage, dirt, chips and excess cutting oil. • Clean or replace components as necessary. 2 Application of thread sealant • Use a thread sealant that is fast drying, sets -up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. • Throroughly mix the thread sealant prior to application. • Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup • For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for '/z"through 2" thread varies from 41/2 turns to 5 turns. • For 21/2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4" thread varies from 51/2 turns to 61/4 turns. ®©o asc-es.com Building connections that last° PS-11.13 page 4 PS-suB-1101-vo120211110 PRODUCTS FOR GROOVED PIPING SYSTE The Gruvlok®System has been manufactured since the late 1960's. The Gruvlok product line has grown from standard couplings and fittings to today's extensive range of grooved product, plain -end product, butterfly valves, check valves, pump protection components, pipe preparation tools and various accessories. M C O 0 Gruvlok is part of our overall commitment to provide today's piping industry with tomorrow's products. o U OLPM c U� us Flm LISTED APPROVED Up For Listings/Approval Details and Limitations, visit our website at 50 • 0._Q�www.anvilintl.com or contact an Anvil® Sales Representative. ®ErsE ISO 9001:2008 ANSI American National Standards Institute API American Petroleum Institute: API Std. 5L, Sect. 7.5 ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers ASME American Society of Mechanical Engineers: Power Piping, B 31.1; Chemical Plant and Petroleum Refinery Piping, B 31.3; Refrigeration Piping, B 31.5; Building Services Piping, B 31.9; Slurry Pipelines, B 31.11 ASTM American Society of Testing and Materials: F 1476, F 1387 AWWA American Water Works Association: C 606 BV Bureau Veritas CDF California State Fire Marshal COE Corps of Engineers: CEGS 15000 CSA Canadian Standards Association: B 242 DNV Det Norske Veritas Hong Kong Fire Services Board New Zealand Insurance Council New Zealand Building Act. (1991) FAA Federal Aviation Administration: HVAC, Plumbing, Fire Protection FHA Federal Housing Administration FM Factory Mutual Engineering Corp. GSA General Services Administration: 15000 Series IAPMO International Association of Plumbing & Mechanical Officials LPC Loss Prevention Council MEA Materials & Equipment Acceptance MIL Military Specifications: MILP-10388 Fittings; MIL-C-10387 Couplings; MIL-P-11087A(CE) Steel Pipe, Grooved MIL-1-45208 Inspection Procedure NASA National Aeronautics and Space Administration: 15000 Series NAVFAC Naval Facilities Engineering Command: NFGS 15000 Series NFPA National Fire Protection Association NIH National Institute of Health (Dept. of Health): 15000 Series NSF NSF International N 0 c ii 4J >Q Certified to NSF/ANSI 61-G = 2 aE o� U v� U U N U � QJ O_ W .�- �= Z 0 C N W � i C co li W tN W al d NY -BSA New York Board of Standards and Appeals o 0 U NYC New York City T, m TVA Tennessee Valley Authority: Fire protection, in storm drains o N o UL Underwriter's Laboratories, Inc. 75 ULC Underwriter's Laboratories of Canada c'� . Bureau of Marine Inspection: Salt and fresh water, oil transfer �U) Bureau of Public Roads; Div. of Bridges: Drain E lines and bridge crossings in a CD Canadian Coast Guard U.S. Coast Guard —Approves each vessel cc o individually co USGBC United States Green Building Council 2 .0-N VA Veterans Affairs :15000 Series n VdS Verband der Sachversicherer e.V. Note- Please refer to product specific pages for exact listings and approvals related to a specific size for a specific product. www.anvilintlxom INTRODUCTION LOK GRUVLOK° - THE ENGINEERED COUPLING HOUSING (A) FLEXIBLE OR RIGID The Gruvlok Coupling housing is designed to self -center around the pipe. The housing encircles and retains the gasket against the application of internal system pressure or vacuum. The housing key sections fit into and engage the pipe -end grooves around the entire pipe circumference, thus restraining the pipe ends from separation due to the application of internal pressure. Flexible Couplings provide designed -in clearances between the housing key sections and the pipe grooves to permit both angular and longitudinal movement of the pipe. Rigid couplings grip the pipe and lock the joint into position. All housings are coated with paint for general service applications. The paint serves to provide protection against normal atmospheric corrosion. However, for couplings used in corrosive environments, hot -dip galvanizing, and stainless steel are available. GASKET (B) The unique single piece "C style design of the gasket has been engineered to provide a pressure responsive, leak -tight seal in both pressure and vacuum applications without the aid of external forces. The "lips' of the gasket are molded so that upon installation onto the pipe ends they provide compression against the pipe surface to establish the leak -tight seal. The gasket cavity functions as a "pressure reservoir" Pressure within the pipe system is applied to the internal surfaces of the gasket which increases the sealing force and enhances the leak -tight seal. In vacuum systems, non -pressure -responsive seals tend to "lift off" the pipe, producing leak paths. However, the Gruvlok gasket reacts to the negative pressure (higher outside atmospheric pressure) as to improve the sealing capability of the gasket. Gasket Reaction to Pressure Gasket l l l l l l l Reaction to Vacuum BOLTS AND NUTS (C) Heat treated oval neck track head bolts serve to connect and secure the housing segments together. The oval neck design prevents turning of the bolt while tightening the hex nut with a single wrench. The bolt size and corresponding wrench (or socket) size for the hex nuts are shown in the chart below. ANSI Bolt Size 3/8 1/2 '/s 3/4 '/s 1 1'A Wrench Size " /16 '/8 016 1'/4 1'/16 1'/8 2 METRIC Bolt Size M10 M12 M16 M20 M22 Wrench Size 16 22 24 30 34 GROOVED PIPE ENDS (D) The ends of the pipe must have a groove in them which may be either cut grooved or roll grooved. The grooved pipe ends engage the coupling keys, thus, providing a self -restraining, mechanical joint capable of resisting the separation of the pipe ends due to the application of system pressure. The groove diameters must be dimensionally accurate to obtain the maximum benefit of the Gruvlok Coupling. GL-6.11 THE GRUVLOKO PIPING METHOD Gruvlok couplings and grooved -end fittings are widely used for joining pipe in a wide variety of piping systems. Gruvlok couplings for grooved -end pipe are designed to provide a self - centering joint which accommodates the application of pressure, vacuum and other external forces, while limiting the burdensome need for special supports, expansion joints, etc. The Gruvlok piping method offers many mechanical design features which benefit the design engineer, the contractor, and the end user. Utilization of the functional characteristics of the Gruvlok coupling will aid in pipe system design and must be considered for proper installation, assembly and performance. The design factors presented in the Gruvlok technical data section should always be referenced to when designing any grooved piping system to obtain the maximum benefit of the Gruvlok piping method. RIGIDITY OR FLEXIBILITY Couplings are available where rigid connections are required. Rigid couplings are clearly marked with an "X" for identification. Couplings with flexible design allow for pipe expansion and contractions with temperature changes. The need for an expansion joint is minimized or eliminated. 'M*L FLEXIBLE RIGID UNION AT EVERY JOINT ■ Gruvlok couplings can be disassembled easily permitting maintenance and servicing of ---------------------------- the piping system. It will facilitate periodic rotation of t t t pipe to distribute internal wear from slurries or other abrasive media. MINIMIZES NOISE & VIBRATION _ The resilient elastomeric gasket and pre -designed gap of the Gruvlok coupling help isolate and absorb noise and vibration, this minimizes vibration transmission. SELF RESTRAINED JOINT The couplings engage the pipe around the entire circumference and restrain the pipe ends from separation due to pressure and other forces, up to the maximum coupling rated END END working pressure. ^ LOAD LOAD STRESS -FREE SYSTEM Flexibility designed in the Gruvlok coupling absorbs and eliminates stress from settlement of buried pipe or those induced by seismic tremors. ACCOMMODATES MISALIGNMENT AND JOINT DEFLECTION The flexibility designed into the Gruvlok coupling will accommodate misalignments caused by imprecise location of pipe opening through walls and floors, will provide pitch for drainage piping systems and facilitate laying pipe on uneven terrain, thus permitting deflection in any direction. �ANVIL �17 ,�rEa�aT,otia GL-9.15 LOK FIG. 7043 Branch Outlet c UL Us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilind.com or contact an Anvil® Sales Representative. MATERIAL SPECIFICATIONS GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade "E" EPDM (Green color code) -40°F to ISOT (Service Temperature Range) (-40°C to 66°C) Recommended for water service, diluted acids, alkalies solutions, oil -free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. HOUSING: Ductile Iron conforming to ASTM A 536, Grade 65-45-12. COATINGS: Rust inhibiting paint - Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) U-BOLT: Plated U-bolt conforming to ASTM A 307 with plated hex nuts conforming to ASTM A 563. LUBRICATION: Standard Gruvlok Gruvlok XtremeTm The Gruvlok Figure 7043 Branch Outlet is for direct connection of sprinkler heads and drop nipples. Just cut a hole, saddle up and fasten it with the U-bolt. The branch outlet provides an economical, quick, and easy outlet at any location along a pipe. Specially engineered to conform to the pipe O.D., the Fig. 7043 provides a leak tight reliable seal in both positive pressure and vacuum conditions. Ductile iron housings with Grade E gasket and carbon steel U-bolt (3/e" dia.) with flanged nuts. Ductile iron housing is available painted or galvanized . The maximum working pressure for all sizes is 175 PSI (12.1 bar). T I FIGURE 7043 BRANCH OUTLET Nominal Diameter Dimensions Specified Torque § Approx. Size O.D.ole . Wt. Each Min. Dia. Max. Dia. A B C Take-out T Min. I Max. In./DN(mm) In./mm In./mm In./mm In./min In./mm In./mm In./mm Ft.-Lbs./N-m Lbs./Kg 11/4 x 1/2 1.660 x 0.840 13/6 1'A 2'/6 31/2 2'/32 1% 27 33 0.8 42.4 x 21.3 30 32 53 89 56 35 - - 0.4 11/4 x 3/4 1.660 x 1.050 13/6 11/4 21/16 31/2 2%2 1% 27 33 0.8 32 x 20 42.4 x 26.7 30 32 53 89 56 35 0.4 11/4x 1 1.660 x 1.315 13/16 11/4 23/16 31/2 2%2 1'/2 27 33 0.9 32 x 25 42.4 x 33.7 30 32 56 89 56 38 - 0.4 11/2 x'/2 1.900 x 0.840 13/16 1'/4 25/32 3'/2 27/32 1 % 27 33 0.8 40 x 15 48.3 x 21.3 30 32 55 89 56 35 - - 0.4 11/2 x % 1.900 x 1.050 13/6 11/4 2%2 31/2 27/32 1 % 27 33 0.8 40 x 20 48.3 x 26.7 30 32 55 89 56 35 - - 0.4 11/2 x 1 1.900 x 1.315 13/6 11/4 2%2 31/2 27/32 1'/2 27 33 0.9 40 x 25 48.3 x 33.7 30 32 58 89 56 38 - - 0.4 2 x'/2 2.375 x 0.840 13/6 1'/4 2'/2 37/s 27/32 1% 27 33 0.8 50 x 15 60.3 x 21.3 30 32 64 98 56 42 - - 0.4 2 x % 2.375 x 1.050 13/16 11/4 21/2 37/s 27/32 1 % 27 33 0.8 50 x 20 60.3 x 26.7 30 32 64 98 56 42 - - 0.4 2 x 1 2.375 x 1.315 13/16 11/4 2% 37/6 2/32 1 % 27 33 0.9 50 x 25 60.3 x 33.7 30 32 67 98 56 1 45 - - 0.4 2Yz x'/2 2.875 x 0.840 13/16 11/4 211/6 4% 2'/32 2 27 33 0.8 65 x 15 73.0 x 21.3 30 32 69 111 56 51 - - 0.4 21/2 x % 2.875 x 1.050 13/16 1'/4 211/16 4% 2�/32 2 27 33 0.9 65 x 20 73.0 x 26.7 30 32 69 111 56 51 - - 0.4 21/2 x 1 2.875 x 1.315 13/e 11/4 213/6 4% 2'/32 2% 27 33 1.0 65 x 25 73.0 x 33.7 30 32 72 111 56 54 - - 0.5 § - For additional Bolt Torque information, see page 274. See Installation & Assembly directions on page 253. Not for use with copper systems. GL-3.14 Z ANVIL 3. SPRINKLER HEADS AND ACCESSORIES DRY PIPE AUTOMATIC FIRE SPRINKLER SYSTEM SPEC SECTION: 2113 16 Bulletin 051 December 2023 Reliable UL Quick Response FM Standard Response '/2" (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Cover plate available in chrome and white as Stan- dard Finishes. Also available in a wide variety of Special Ap- plication Finishes. 3. Cover plates with gaskets are available to limit dust and air movement through the ceiling. 4. Available in Ordinary or Intermediate temperature rat- ing. 5. Sprinkler available in lengthsfrom 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm) incre- ments (see Fig. 1). Approvals & Listings 1. Listed by Underwriters Laboratories and Certified for Can- ada (cULus) as a Quick -response sprinkler for Light and Ordinary Hazard occupancies. UL Guide Number VNIV, Sprinklers, Automatic and Open. 2. FM Approved as a Standard -response sprinkler. Patents The Model G5-56 Dry is covered by the following patents: U.S. 5,775,431 U.S. 5,967,240 Application The Model G5-56 Dry is a cULus Listed Quick Response Con- cealed Dry Pendent sprinkler intended for use in accordance with NFPA 13. The Model G5-56 Dry sprinkler is cULus Listed for use in Light and Ordinary Hazard occupancies. The Model G5-56 Dry is FM Approved as a Standard Re- sponse Concealed Dry Pendent sprinkler intended for use in ac- cordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-56 Dry sprinkler is a Dry Pendent sprin- kler, where the sealing washer is located at the inlet end of the sprin- kler assembly. The position of the sealing washer is controlled by a fusible element at the opposite end of the sprinkler assembly. The sprinkler is installed with the fusible element at the ceiling of a pro- tected space that may be subject to freezing temperatures and the inlet orifice located in a heated area above the ceiling. Operation of the fusible element allows the sealing washer to move out of the inlet Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler Model Gb-b6 Dry Sprinkler orifice admitting water from the supply piping. The sprinkler uses a fast -response fusible element with an Ordinary, 165°F (74°C), or Intermediate, 212°F (100°C), temperature classification. The Model G5-56 Dry sprinkler has a dropdown deflector design that allows the sprinkler to be recessed into the ceiling and con- cealed by a flat cover plate. The cover plate assembly threads into the sprinkler's cup and provides 'h-inch (13mm) of cover adjust- ment. The cover plate assembly consists of a flat cover plate that is attached to the skirt using either 135°F (57°C) or 165°F (74°C) temperature rated solder. The 135°F (57°C) cover plates are for use with Ordinary temperature classification sprinklers and the 165' (74°C) cover plates are for use with Intermediate temperature clas- sification sprinklers. The Model G5-56 Dry sprinkler is available in lengths ranging from 4'/4 inches (108mm) to 48 inches (1219mm) in'/4-inch (6.35mm) increments (see Fig. 1). The length of the sprinkler must be selected to provide the Exposed Minimum Barrel Length in a Heated Area required by Fig. 2. The Model G5-56 Dry sprinkler is available with 1-inch NPT or ISO 7-1 R1 threaded inlet fittings. The standard inlet fitting includes a long inlet designed to minimize the potential for water, scale, and sediment to accumulate on the sprinkler inlet in wet- and dry -pipe sprinkler systems. For wet -pipe sprinkler system applications where the standard inlet interferes with installation into existing plastic pipe fittings, an inlet fitting is available with a short ("PL') inlet. See Fig. 3 for further information. CD c Z 0 0 3 CT ND 0 N) W Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Nominal Orifice Size:'/2-inch (15mm) Thread Size: 1-inch NPT per ANSI B2.1 or ISO 7-1 R1 Nominal K Factor: 5.6 (80 metric) Maximum Working Pressure: 175 psi (12 bar) — 100% fac- tory hydrostatically tested to 500 psi (34.5 bar) Sprinkler Installation Wrench: Model FC wrench Sprinkler Identification Number (SIN): RA5114 Materials: See Fig. 4 "A" Dimension Temperature Rating Cover Max. Classification Sprinkler plate Ambient Temp. Ordinary 165°F (74°C) 135°F (57°C) 100°F (38°C) Intermediate 212°F (100°C) 165°F (74°C) 150°F (66°C) �-- —� --- L- - System Fitting 2-5/8" [67 mm] Dia. Hole in Ceiling 2-5/16" [59 mm] Nominal Position of Cover Plate Cover Plate Assembly 1 Ceiling 1/4" [6 mm I Min. to 5/8" [16 mm] Max. Dropped Deflector to Ceiling Inlet Threads Sprinkler Cup Assembly 1/2" [12 mm] Total Cover Plate Adjustment 1/4" [6 mm] Cover Plate Adjustment 91." 1 /4" [6 mm] 051 FG01 B Cover Plate Adjustment Fig. 1 Note: The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [7'/2 threads approximately]. "A" Dim. 4'/4 to 48" (108mm to 1219mm) in W (6.35mm) increments 2. Cover Plate Finishes Standard Finishes White Paint Chrome Special Application Finishes Off White Paint Black Paint Custom Color Paint —Speck') Raw Brass (Lacquered) Bright Brass Finished Bronze Satin Chrome Stainless Steel Clad(2) Custom Printed 11 C=1 300A Sprinkler Wrench (') Custom color paint is semi -gloss, unless specified otherwise. (2) Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Cover plates are not listed or ap- proved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Optional Cover Plate with Gasket* Model G4/G5 Model G4/G5 SR Gasket QR Gasket Cover Plate Cover Plate (FM Approved) (cULus Listed) * Model G4/G5 QR Gasket and Model G4/G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G4 /G5 QR Gasket and Model G4 /G5 SR Gas- ket cover plates and gaskets are not interchangeable. Installation Instructions Model G5-56 Dry sprinklers must only be installed in standard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. DO NOT install dry sprinklers into elbows, couplings (including couplings on drops), welded outlets, mechanical tees, or gasket -sealed CPVC fittings. In all installations, including into CPVC piping, the dry sprinkler shall be installed with protrusion into the fitting in accordance with the installation diagrams in this Bulletin. Installation of the Model G5-56 Dry sprinkler is not recom- mended in copper pipe systems, as this may reduce the life ex- pectancy of the sprinkler. Do not install Model G5-56 Dry sprin- klers with the standard (long) inlet fitting into CPVC adapter fittings or tees that have an internal obstruction (see Fig. 3); this will damage the sprinkler, the fitting, or both. A short inlet ("PU) version of the Model G5-56 Dry sprinkler is available for use in existing installations with CPVC adapter fittings or tees having an internal obstruction; Model G5-56 sprinklers with the short inlet fitting shall not be used on dry -pipe sprinkler systems. The Model G5-56 Dry sprinkler and the cover plate assembly are not intended for installation in corrosive environments, includ- ing, but not limited to, those with salt aerosols or chlorine. Model G5-56 Dry sprinklers must be installed with the Ex- posed Minimum Barrel Length required by Fig. 2 located in a Heated Area. Do NOT install the sprinkler in ceilings which have positive pressure in the space above. The following steps must be followed for installation: 1. Cut a 25/8-inch (67mm) diameter hole in the ceiling directly in -line with the outlet of the tee. 2. Apply pipe joint compound or Polytetrafluoroethylene (PTFE) tape to the threads of the sprinkler's inlet fitting. 3. A protective cap is provided to protect the drop -down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove the cap to install sprinkler, Step 4, then reinstall cap until the cover plate is installed. 4. Install the sprinkler in the tee using the Model FC wrench. The Model FC wrench has a socket drive which is inserted into the sprinkler's cup and around the body of the sprinkler prior to installation of the sprinkler. Do NOT wrench any of the part of the sprinkler/cup assembly. The sprinkler is then tightened into the pipe fitting to achieve a leak free connec- tion. The recommended minimum to maximum installation torque is 22-30 lb-ft (30 — 40 N-m). When inserting or re- moving the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Rein- stall the protective cap following installation of the sprinkler, until the cover plate is installed. a. Alternatively, where access to the outer tube of the sprinkler is available, the Model G5-56 Dry sprinkler may be installed using a pipe wrench. The protec- tive cap should not be removed to install the sprin- kler with a pipe wrench. The pipe wrench shall only be permitted to interface with the steel outer tube portion of the sprinkler (Item #8 in Fig. 4). Do NOT wrench any other portion of the sprinkler/cup as- sembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consider- ation should be given to the need for future removal of the sprinklers because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22-30 lb-ft (30 — 40 N-m). 5. To install the cover plate, remove the protective cap and in- stall the cover plate by hand turning the cover in the clock- wise direction until it is tight against the ceiling. For Model G4 /G5 QR Gasket and Model G4 /G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt only. Do not glue the gasket in place or allow the gasket to overlap both the cover plate and the flange of the skirt. 3. is MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM AMBIENT TEMPERATURE OF PROTECTED AREA* AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40oF/4°C 1 50oF/10°C 60oF/16oC EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. (MM) IN. (MM) IN. (MM) 40oF(4oC) 0 0 0 30oF(-1°C) 0 0 0 20°F (-7°C) 4 (100) 0 0 10°F (-12°C) 8 (200) 1 (25) 0 0°F (-18°C) 12 (300) 3 (75) 0 -10°F (-23°C) 14 (350) 4 (100) 1 (25) -20°F (-29°C) 14 (350) 6 (150) 3 (75) -30oF (-34oC) 16 (400) 8 (200) 4 (100) -40oF (-4OoC) 18 (450) 8 (200) 4 (100) -50oF (-46oC) 20 (500) 10 (250) 6 (150) -60oF (-51°C) 20 (500) 10 (250) 6 (150) * FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ** THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. *** THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. WET PIPE nn i --at---�:j MINIMUM EXPOSED BARREL LENGTH INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER INTO THE 1 INCH NPT SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI B 16.3 (CLASS 150) OR CAST IRON THREADED TEE FITTING PER ANSI 16.4 (CLASS 125) ONLY. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL - - CAUSE CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. (HEATED AREA) IF NECESSARY, SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER CUP TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA. i "A" DIMENSION CEILING CLEARANCE HOLE (PROTECTED AREA) Fig. 2 3 5/16" DIA. DO NOT BLOCK VENT HOLES ON TOP OF CUP. COVER PLATE INSIDE SURFACE OF INSULATION, WALL, OR CEILING 051FG02A *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction Female Female Pipe Pipe Thread --,--'Thread CPVC Fitting with Internal Obstruction CPVC itting - No Internal Obstruction I 1 � Shorter Longer Inlet Inlet Male Male Pipe Pipe Thread Thread 7/\" Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET2 Fig. 3 5. Maintenance The Model G5-56 Dry should be inspected and the sprin- kler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Replace any sprinkler that has been painted (other than factory applied) or damaged in any way. Con- cealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinkler should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Engineering Specification Model G5-56 Dry Pendent Concealed Sprinkler Dry pendent sprinklers shall be dry pendent concealed sprin- klers with a flat cover plate. Sprinklers shall be cULus Listed as Quick Response for Light and Ordinary Hazard applications as well as FM Approved as Standard Response. Sprinklers shall be available in lengths from 4'/4 inches (108mm) to 48 inches (1219mm) in %-inch (6.35mm) increments based on face of fitting to finished ceiling distance. Sprinkler length shall be selected to provide the Exposed Minimum Barrel Length based on the minimum design temperature in the protected area and the minimum temperature in the conditioned space where the barrel is located in accordance with the Manufac- turer's written installation instructions. Sprinklers shall have [1-inch NPT][ISO 7-1 R1] threaded inlet fittings with [standard length inlets designed for use with wet- or dry -pipe sprinkler systems][short length inlets designed for use with wet -pipe sprinkler systems having pipe fittings with internal obstruc- tions that prevent the insertion of standard length inlets]. Sprinklers shall have a PTFE coated beryllium nickel Belleville spring washer inlet seal and brass alloy cap that prevent water entry from the sprinkler system piping into the sprinkler prior to actuation. Sprinklers shall have a fast -response fusible link that controls the movement of the inlet seal and cap through a mechanism consisting of link arms, a seat adapter, an ori- fice adapter, an inner tube, and a yoke. Sprinklers shall use a drop down deflector supported by tapered pins. Sprinklers shall have a galvanized steel cup for threaded attachment of the flat cover plate assembly. Cover plate attachment shall provide up to 1/2-inch (13mm) of adjustment. Sprinklers shall be [Ordinary temperature classification, 165°F (74°C), with 1350F temperature rated cover plates][Intermediate tempera- ture classification, 212°F, with 1650F temperature rated cover plates]. Cover plates shall be [solid][perforated] with factory applied [White] [Chrome] [Special Application — Specify] finish. Dry pendent concealed sprinklers shall be Reliable Model G5- 56 Dry (SIN RA5114). Ordering Information Specify: 1. Sprinkler: Model G5-56 Dry 2. Threads: [I-inchNPT - standard][ISO 7/1 R1 - optional] 3. Inlet Length: [Standard][Short ("PU)— for existing wet - pipe installations only] 4. Cover Plate Finish: [White] [Chrome] [Special Application — Specify] 5. Sprinkler/Cover Plate Temperature Rating: [Ordinary — 165°F sprinkler with 135°F cover plate] [I ntermed iate — 212°F sprinkler with 1657 cover plate] 6. Nominal Sprinkler Length (face of fitting to face of ceiling - "A' Dimension from Fig. 1): [Specify length — Lengths available from 4'/4 inches to 48 inches (108mm to 1219mm) in'/4-inch (6.35mm) increments] MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL 1 BODY, MA %CH. DZR BRASS 2 DEFLECTOR COPPER ALLOY 3 DEFL. SPUTTER BRASS ALLOY 4 DEFL. PIN STAINLESS STEEL 5 MEGA -INLET DZR BRASS 6 LINK ASSY. NICKEL/BERYLLIUM NICKEL 7 LEVER COPPER ALLOY 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY 10 FLIP DISK BRASS ALLOY 11 CAP BRASS ALLOY 12 WASHER PTFE COATED BERYLLIUM NICKEL 13 SETSCREW STAINLESS OR ALLOY STEEL 14 LOAD SCREW STAINLESS STEEL 15 BOTTOMCUP GALVANIZED STEEL 16 TOP CUP GALVANIZED STEEL 17 ADJ. SEAT ADAPTER BRASS ALLOY 18 YOKE BRASS ALLOY 19 CLOSURE YOKE BRASS ALLOY 20 ORIFICE ADAPTER BRASS ALLOY (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 'G04 Fig. 4 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 12/23 P/N 9999970480