Loading...
APPROVED FIR2023-0011+Fire_Alarm_Plan+2.13.2023_10.25.43_AM+3365957OPERATIONAL MATRIX SYSTEM OUTPUTS Required Fire Safety Control System Actions Central Station FACP Annunciation ,gym ti .o .m) wm c co .o �wm , 0 a do j c o `Lo o �` c o w O o iF °j C, m iF 0 F 10 Q iA. 8, .p 0 Q o o �F �o 40 6 ?obi° +� m �. P c O QQQ QQo SYSTEM INPUTS A B C D E F G H I J 1 Manual Fire Alarms 1 Q 2 FACP Smoke Detector ♦ ♦ ♦ ♦ 2 Q 3 Sprinkler Waterflow 3 4 Unused 4 5 Sprinkler Tamper 5 LU6 Sprinkler Backflow 6 7 Unused 7 fn 8 Unused $ 9 Fire Alarm AC Power Failure 9 LU 10 Fire Alarm System Low Battery 10 11 Open Circuit 11 0 12 Ground Fault 12 F- 13 Notification Appliance Circuit Short 13 14 Transmitter Trouble 14 AIBICIDIEIFIGIHIIIJ VICINITY MAP 1 � I t � r"� '��i Nor All Lvnnwood Paradise Ln,, ds., WA 98020, Richmond Highlands ,v I ABBREVIATIONS USED IN THE DRAWING AIM ADDRESSABLE INPUT MODULE cd CANDELA D DETECTOR EOL END OF LINE FACP FIRE ALARM CONTROL PANEL IBC INTERNATIONAL BUILDING CODE IFC INTERNATIONAL FIRE CODE L1 SLC LOOP 1 M MODULE N1 NAC #1 N2 NAC #2 r NAC NOTIFICATION APPLIANCE CIRCUIT NEC NATIONAL ELECTRICAL CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION ntc NOT TO SCALE RPS REMOTE POWER SUPPLY SLC SIGNAL LINE CIRCUIT WP WEATHERPROOF ZN ZONE BF BARRIER FREE (ADA) PARADSE HE0G�13 � BLDG B �0D[� a�Q�H 8 ALLA OH EIDMOHIDS9 �Q INSTALLATION DETAILS DEVICE SYMBOL I QTY, MANUFACTURER PART NO. DESCRIPTION FIRE ALARM HEAD -END EQUIPMENT FACP 1 GAMEWELL GWF-7075 ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL, RED FA -ES I1 AES 7707-88—ULP WIRELESS COMMERCIAL FIRE ALARM COMMUNICATOR FDOCI 1 HONEYWELL GW—FAD FIRE ALARM DOCUMENT CABINET W/ USB SP 1 ASCO MODEL 175 TRANSIENT SUPPRESSION MODULE 1 ASCO PCB1B TRANSIENT SUPPRESSION MODULE BASE 2 DURACELL 12VDC, 8AH BATTERIES FOR FIRE ALARM CONTROL PANEL 1 DURACELL 12VDC, 12AH BATTERY FOR AFS 2.0 RADIO FIRE ALARM INITIATION DEVICES 0 4 GAMEWELL ASD—PL3 ADDRESSABLE, PHOTO, DET. P 4 GAMEWELL B300-6 BASE B300-6, BASE FOR ADDRESSABLE DETECTORS 0135° 4 GAMEWELL ATD—L3R ADDRESSABLE 135°F ROR HEAT DETECTOR 4 GAMEWELL B300-6 BASE B300-6, BASE FOR ADDRESSABLE DETECTORS ❑F 1 GAMEWELL MS-7ASF ADDRESSABLE PULL STATION AIM 2 4 GAMEWELL AMM-21F ADDRESSABLE DUAL MONITOR MODULE AOM 5 GAMEWELL AOM-2RF ADDRESSABLE RELAY MODULE FIRE ALARM NOTIFICATION DEVICES LF 16 SYSTEM SENSOR HWL-LF LSERIES , LOW FREQU. HORN, WALL, WHITE 3 SYSTEM SENSOR PC2WL HORN/STROBE, CEILING, WHITE WP 1 SYSTEM SENSOR P2RK HORN / STROBE, WP, WALL, RED FIRE ALARM DEVICES BY OTHERS g1 BY OTHERS BY OTHERS WETFLOW SWITCH DF 1 BY OTHERS BY OTHERS DRYFLOW SWITCH PS 1 BY OTHERS BY OTHERS GENERIC LOW AIR PRESSURE SWITCH 4 BY OTHERS BY OTHERS TAMPER SWITCH Plv 1 BY OTHERS BY OTHERS POST INDICATOR VALVE Approved DFM Chris gust South County Fire Date: 02/24/2023 02-24-2023 PLAN REVIEW NOTE: APPROVED WITH CONDITION: 1. INSTALL ONE EXTERIOR STROBE NEAR RISER ROOM. THIS WILL BE IN ADDITION TO THE CURRENTLY LOCATED HORN/STROBE. DFM BURT PARA ISE BUILD G A 546 P AD 1ISE LANE DMO S, WA. 98021 4" MIN 12" MA) PARADISE HEIGHTS BU,(LDING B _ 550)PARADISE LANE EDMONDS, WA. 98020 Fa. MINI HEAT DETECTOR SITE PLAN RISER ROOM '__1 OUTDOOR ;—�HGRN/STROBE F� PARADISE HEIGHTS BUILDING C 554 PARADISE LANE EDMONDS, WA. 98020 DEVICE INSTALLATION REQUIREMENTS A/C SUPPLY OR RETURN DIFFUSER PENDANT AUDIE 6" 'MIN. 36" MIN. I AUDIBLE/VISUAL AUDIBLE -ONLY REMOTE ALARM CEILING MOUNTEDJ/ CEILING MOUNTED EVER AND/OR VISUAL APPLIANCES - INDICATOR SMOKE/HEAT AUDIBLE/VISUAL HERE ONLY APPLIANCE IlO DETECTOR APPLIANCES o WALL -MOUNTED HEAT DETECTOR DOOR WIDTH r LESS 3� FSA MAGNETIC S 30' MAX FACP HOLDER DOOR AFF RECORDS.82^_96" 82-96" MIN. 10' MAX 30' 7 1 DOCUMENTS TO LOWEST WHERE CEILING A A PART OF LENS HEIGHT ALLOWS 5' MAX. 66" TO 66" TO 66" TO FROM EXIT TOP OF TOP OF TOP OF ® I FSA FACP CABINET MANUAL PULL 42,-48" FINISH FLOORED STATION AC, NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST POINT OF DETECTOR 12" MAX WALL -MOUNTED SMOKE DETECTOR SIDE WALL MAX -F FINISHED WALL T SHEET INDEX SHEET # SHEET DESCRIPTION FA 0.0 FIRE ALARM INSTALLATION DETAILS FA 1.0 FIRST & SECOND FLOOR FIRE ALARM PLAN FA 2.0 THIRD FLOOR FIRE ALARM PLAN, ENLARGED SPRINKLER RISER ROOM & ELEVATOR MACHINE ROOM FA 3.0 BATTERY / POINT TO POINT VOLTAGE CALCULATIONS & SINGLE LINE RISER DIAGRAM SCOPE OF WORK FIRE ALARM INSTALLATION PER PLAN FOR A NEW FULLY SPRINKLED 3-STORY RESIDENTIAL BUILDING, WITH ONE LEVEL BEING GARAGE. INSTALLATION OF (1) ADDRESSABLE FACP, (1) AES RADIO COMMUNICATOR, (1) FIRE ALARM DOCUMENT CABINET, (4) ADDRESSABLE SMOKE DETECTORS, (1) ADDRESSABLE PULL -STATION, (4) ADDRESSABLE HEAT DETECTORS, (1) WET SPRINKLER SYSTEM MONITORING (THAT INCLUDES A WATERFLOW, TAMPER, BACKFLOW AND PIV), (1) DRY SPRINKLER SYSTEM MONITORING (THAT INCLUDES A DRYFLOW, TAMPER AND LOW AIR PRESSURE SWITCH), (1) ELEVATOR RECALL SYSTEM, (2) ELECTRIC DOOR HOLDERS, AND (20) BUILDING NOTIFICATION DEVICES. CONTACT INFO OWNER FIRE ALARM CONTRACTOR REFENT CONSTRUCTION, INC FIRE PROTECTION INC 7305 SOUNDVIEW DRIVE 17410 ASH WAY, SUITE 8 EDMONDS, WA 98026 LYNNWOOD, WA 98037 CONTACT : ROB MICHEL CONTACT : DAVID MOW PHONE 206.930.2445 PHONE 425.290.9600 EMAIL RWMICHEL1 @ME.COM EMAIL DAVID@FPISEATTLE.COM CODE INFORMATION AUTHORITY HAVING JURISDICTION: CITY OF EDMONDS BUILDING CODE: INTERNATIONAL BUILDING CODE, 2015 EDITION FIRE CODE: INTERNATIONAL FIRE CODE, 2015 EDITION MUNICIPAL CODE: CITY OF EDMONDS BUILDING USE AND OCCUPANCY: R-2 (FULLY SPRINKLED) STANDARDS: NFPA-70 (NEC), NFPA-72, IBC, IFC, & WAC 51-50 CLASSIFICATION OF SUPERVISING STATION: REMOTE SUPERVISING STATION NAME OF SUPERVISING STATION: STANLEY SECURITY, INC TAX PARCEL NUMBER: 27032500302600 INSTALLATION NOTES 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 2. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. 3. CABLE ROUTING SHOWN ON DRAWINGS IS FOR INTENT. EXACT ROUTING TO BE COORDINATED WITH OTHER TRADES IN THE FIELD. SEE SPECIFICATIONS AND DRAWING NOTES FOR ACCEPTABLE INSTALLATION METHODS. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES. 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. 6. POWER -LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NON -POWER LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NON -POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 7. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION EQUIPMENT. WHERE INSTALLED EXPOSED, CABLES SHALL BE ADEQUATELY SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR, IT SHALL BE RUN IN RACEWAY. 8. VERIFY ALL CEILING HEIGHTS AND CEILING TYPES WITH CONTRACTOR DUE TO NOT HAVING A LOT OF INFORMATION TO WORK WITH AND BUILDING THE SCHEMATICS OURSELVES. 9- SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED 100%. 10. WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME WHETHER THEY ARE IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THE FLASH OF THOSE STROBES SHALL BE SYNCHRONIZED (NFPA-72, SECTION 18.5.4.3.2(3) & (4). 11. THE MEANS OF SIGNAL TRANSMISSION TO THE REMOTE SUPERVISING STATION SHALL BE VIA THE FACP'S ONBOARD DACT AND A UL LISTED AES WIRELESS RADIO COMMUNICATOR. 12• ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). ALL INITIATING DEVICES AND DEVICES CONTAINING EOL'S SHALL HAVE A PHYSICAL LABEL IDENTIFYING THE DEVICE'S ADDRESS / END OF LINE RESISTOR. 13, INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD DRAWINGS OTHERWISE REFERRED TO AS ("AS -BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM DOCUMENT CABINET NEXT TO THE FACP (NFPA-72 10.18.2.3). 14. PRIOR TO CALLING FOR INSPECTION, THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE SYSTEM HAS BEEN INSTALLED, TESTED, EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE APPROVED PLANS. THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN NFPA-72 RECORD OF COMPLETION (NFPA-72 10.18.2.1.1). THE COMPLETED RECORD OF COMPLETION ALONG WITH THE AES RADIO TABLE REPORT SHALL BE PROVIDED TO THE AHJ INSPECTOR PRIOR TO REQUESTING A FIRE FINAL INSPECTION (NFPA-72 10.18.2.1.2.4). ?✓� FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM NFFi 000805173 ROY L CATS 4 tP� w � Y NFPA'^ CFPS #14T3 CN v a *k N u: Z U w Ewa) W fn O U = U > a U J N L)000a z>.w=w m5" O W m wWa H O 2 zW_j F w o Www0sM a o�cnJa o REVISION RECORD DATE / DESCRIPTION RECEIVED Feb 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2023-0011 DATE: 02/03/2023 PROJECT NAME = W Q O N 00 (D _j a) W = ZLLJ W 0 Q 0 Q a _j m Q Q a U.) LO Z Q 0 W SHEET TITLE I FIRE ALARM PROJECT DETAILS SHEET NUMBER 1 FA OmO CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. ( (2/M ft) DESCRIPTION A 14/4 FPLR 14 3.07 NAC : NOTIFICATION APPLIANCE CIRCUIT U 18/4 FPLR 18 7.77 SLC :SIGNALING LINE CIRCUIT Z 18/2 FPLR 18 7.77 IDC : ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) FIRST FLOOR PLAN N� SCALE: 1 /8" = 1' Fire Alarm Device Identification (SLC) ADDRESSABLE DEVICES NOTIFICATION DEVICES CIRCUIT CANDELA DEVICE TYPE ADDRESS F NAC CIRCUIT # DEVICE # `DEVICE r- SLC • D005 O N1. 001 Y� 15 CD LF INSTALLATION KEY NOTES # KEY NOTE 10 A DEDICATED 120VAC POWER CIRCUIT IS REQUIRED FOR THE NEW FIRE ALARM PANEL. A DEDICATED 120VAC POWER OUTLET IS REQUIRED FOR THE AES RADIO COMMUNICATOR, CAN USE FACP CIRCUIT. ® A NEW DOCUMENT ENCLOSURE. ® VERIFY LOCATION OF ELEVATOR DOOR HOLDER AND POWER FOR SAID DOOR HOLDER. ® FIELD VERIFY FIRE SPRINKLER DEVICE LOCATIONS. © TRANSIENT SUPPRESSION MODULE FOR PROTECTING WIRING GOING OUTSIDE. 0 OUTDOOR DEVICE TO BE EASILY SEEN ON APPROACH FOR FIRE DEPARTMENT. ® HEAT DETECTOR USED FOR ELEVATOR RECALL DUE TO CLOSE PROXIMITY TO THE UNIT KITCHEN. I I DINING ROOM FIEAT I KITCHEN I N2.004 (LAUNDRY I BED #2 C N2.003 I N2.002 BED #3 1 DOWN TO 2 ON FA( M BED NL1.004 EOL 110cd 2 0 WP DECK 3 - B A: DOWN TO N2-003 IN DECK HALLWAY I UNIT201 DINING I I LIV U: UP TO UNIT 302 LOBBY HEAT A LIV UNIT 202 I I ® EL T ® KITCHEN 1 1 L1 L1 •D006 U N2.005 0 BATH A I BED # ® � I STAIR I N 2.006 Z J J TI U N2.007 I BED ED #3 N2.001 cc M BATH ® I� n A:IJP TO UNIT M BATH N2.008 30? MSTR BDR MASTER BED - -V F L SECOND FLOOR PLAN N� SCALE: 1 /8" = 1' FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS gDTECjpf�� wo r NFRA CFPS #14T3 T 00 CD r CD k N W>_ ❑ U t- W Z U W 0) W W U J � d co co z U 0 H U J a QLU Q U ❑ ❑ CD Z >. W -j LL m�." o ❑ U.� H o m V 2 Z3: J W 3:w�- a ❑ WWWC°x a ❑ a'fnJ a ❑ REVISION RECORD DATE / DESCRIPTION RECEIVED Feb 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2023-0011 DATE: 02/03/2023 PROJECT NAME Cn ~ = W Z Q CD CD oo CM W = (' Z W Q Cn p Q a m Q Q a LO 0_j Z Q � in W SHEET TITLE FIRE ALARM FIRST & SECOND FLOOR PLAN SHEET NUMBER FA 1.0 . W: D 0— N1.004 EOL 110cd \ND THIRD FLOOR PLAN N SCALE: 1/8" = 1' 0' 1 ' S' 10' 20' CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. (f2/Mft) DESCRIPTION A 14/4 FPLR 14 3.07 NAC : NOTIFICATION APPLIANCE CIRCUIT U 18/4 FPLR 18 7.77 SLC :SIGNALING LINE CIRCUIT Z 18/2 FPLR 18 7.77 IDC : ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) Fire Alarm Device Identification (SLC) ADDRESSABLE DEVICES NOTIFICATION DEVICES CIRCUIT CANDELA DEVICE TYPE ADDRESS NAC CIRCUIT # DEVICE # F—DEVICE F- SLC • D005 O N1. 001 �;) 15 CD LF INSTALLATION KEY NOTES # KEY NOTE 1� A DEDICATED 120VAC POWER CIRCUIT IS REQUIRED FOR THE NEW FIRE ALARM PANEL. 20 A DEDICATED 120VAC POWER OUTLET IS REQUIRED FOR THE AES RADIO COMMUNICATOR, CAN USE FACP CIRCUIT. 30 A NEW DOCUMENT ENCLOSURE. ® VERIFY LOCATION OF ELEVATOR DOOR HOLDER AND POWER FOR SAID DOOR HOLDER. O5 FIELD VERIFY FIRE SPRINKLER DEVICE LOCATIONS. © TRANSIENT SUPPRESSION MODULE FOR PROTECTING WIRING GOING OUTSIDE. O OUTDOOR DEVICE TO BE EASILY SEEN ON APPROACH FOR FIRE DEPARTMENT. ® HEAT DETECTOR USED FOR ELEVATOR RECALL DUE TO CLOSE PROXIMITY TO THE UNIT KITCHEN. DHs — I OMOO8 1 OM009 ACKFLOWS ENLARGED FIRE SPRINKLER ROOM SCALE:NTS ---(9 1 •M011 RIMARY RECALL 1 •M 012 ,LTERNATE 1 •M 013 IRE HAT RECALL 1 •M 014 REV DAMPER 2 ENLARGED ELEVATOR MACHINE ROOM SCALE:NTS I emool ULL FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM INFP 1 000805173 ROY L CATS ,qpw0TEr 0 r NFPA: CFPS #1473 r N r � 'qa) r p k N r = �* a � w >_ o U H w Z LU U > w �w°' ' w 9 fn O U = Q uu) U > U J N �oLOUoa zLu m5 O O m LU Lu wwQ 2 Z W J wa. 0 xww0sx a 0IXcnJli o REVISION RECORD DATE / DESCRIPTION RECEIVED Feb 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2023-0011 DATE: 02/03/2023 PROJECT NAME 0) = LV Q O CV 000 (' m J a) W = Z W S Q Lu cn p�az Q a - m ao a Ln Ln Q p LLB SHEET TITLE I FIRE ALARM THIRD FLOOR PLAN ENLARGED ROOMS SHEET NUMBER I FA 10 BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) PANEL COMPONENTS QTY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL 1 GWF-7075 Main Board Intelligent Fire Alarm Control Panel Main Board 0 0 0 0 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) AIM 2 4 AMM-21F Addressable Dual Monitor Module 0.0007 0.0028 0.0007 0.0028 AOM 5 AOM-2RF Addressable Relay Module 0.0003 0.0015 0.0003 0.0015 L1 S P 4 ASD-PL3 / B300-6 BASE Addressable, Photo, Det. 0.0003 0.0012 0.0003 0.0012 0 4 ATD-1-3 / B300-6 BASE Intelligent Addressable 135°F (57°C) Thermal Detector W/ 6" Detector Base 0.0003 0.0012 0.0003 0.0012 ❑F 1 MS-7ASF Addressable Pull Station 0.0003 0.0003 0.007 0.007 Ell WP 1 P2RK Horn/Strobe,WP,Wall , Red 110cd 0 0 0.221 0.221 N1 H 3 PC2WL Horn/Strobe, Ceiling, White 15cd 0 0 0.071 0.213 N2 11-Fl< 16 HW-LF Low Frequency Horn, Wall, White 0 0 0.111 1.776 TOTAL STANDBY (A) 0.007 TOTAL ALARM (A) 2.2237 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.007 24 0.17 SECONDARY ALARM LOAD (A) 2.2237 0.08 0.19 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 0.35 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 0.42 PROVIDE (2) 12V 7AH BATTERIES *BATTERY BOX SIZE CAPACITY NOT SPECIFIED. REFER TO MANUFACTURER DOCUMENTATION. BATTERY CALCULATIONS RPS•N2.008 RPS•N2.009 RPS-N2-010 RPS•N2.011 RPS•N2.012 RPS-N2-013 RPS-N2-014 EOL N1 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.89 Min. Operational Voltage: 16 End Of Line Voltage: 19.51 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 4.34 Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.434 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 507 Spare Current (A): 2.066 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 3.112993 Spare Current (A) Percent: 82.64 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (0) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent Nl-001 PC2WL Horn/Strobe, Ceiling, White 15cd 0.071 0.434 131 0.804916 0.35 20.05 0.35 1.71 % Nl-002 PC2WL Horn/Strobe, Ceiling, White 15cd 0.071 0.363 15 0.0933 0.03 20.02 0.38 1.88 % Nl-003 PC2WL Horn/Strobe, Ceiling, White 15cd 0.071 0.292 31 0.190537 0.06 19.96 0.44 2.15 % N1-004 EOL P2RK Horn/Strobe,WP,Wall , Red 110cd 0.221 0.221 330 2.02424 0.45 19.51 0.89 4.34 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (0/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) N2 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 2.63 Min. Operational Voltage: 16 End Of Line Voltage: 17.77 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 12.90 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 1.776 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 383 Spare Current (A): 0.724 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 2.350422 Spare Current (A) Percent: 28.96 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (0) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent N2-001 HW-LF Low Frequency Horn, Wall, White 0.111 1.776 100 0.614 1.09 19.31 1.09 5.35 % N2-002 HW-LF Low Frequency Horn, Wall, White 0.111 1.665 13 0.077819 0.13 19.18 1.22 5.98 % N2-003 HW-LF Low Frequency Horn, Wall, White 0.111 1.554 16 0.096556 0.15 19.03 1.37 6.72 % N2-004 HW-LF Low Frequency Horn, Wall, White 0.111 1.443 16 0.1001 0.14 18.89 1.51 7.42 % N2-005 HW-LF Low Frequency Horn, Wall, White 0.111 1.332 32 0.199071 0.27 18.62 1.78 8.72 % N2-006 HW-LF Low Frequency Horn, Wall, White 0.111 1.221 26 0.15698 0.19 18.43 1.97 9.66 % N2-007 HW-LF Low Frequency Horn, Wall, White 0.111 1.11 2 0.01089 0.01 18.42 1.98 9.72 % N2-008 HW-LF Low Frequency Horn, Wall, White 0.111 0.999 12 0.073295 0.07 18.34 2.06 10.08 % N2-009 HW-LF Low Frequency Horn, Wall, White 0.111 0.888 50 0.307 0.27 18.07 2.33 11.42 % N2-010 HW-LF Low Frequency Horn, Wall, White 0.111 0.777 12 0.073295 0.06 18.01 2.39 11.70 % N2-011 HW-LF Low Frequency Horn, Wall, White 0.111 0.666 2 0.01089 0.01 18.01 2.39 11.73 % N2-012 HW-LF Low Frequency Horn, Wall, White 0.111 0.555 26 0.15698 0.09 17.92 2.48 12.16 % N2-013 HW-LF Low Frequency Horn, Wall, White 0.111 0.444 32 0.199071 0.09 17.83 2.57 12.59 % N2-014 HW-LF Low Frequency Horn, Wall, White 0.111 0.333 16 0.1001 0.03 17.8 2.6 12.76 % N2-015 HW-LF Low Frequency Horn, Wall, White 0.111 0.222 16 0.096556 0.02 17.78 2.62 12.86 % N2-016 EOL HW-LF Low Frequency Horn, Wall, White 0.111 0.111 13 0.077819 0.01 17.77 2.63 12.90 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (0/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) POINT TO POINT VOLTAGE DROP CALCULATIONS L1 -DO06 L1 •DO07 135° 135' FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM NFP 000805173 ROY L CATS 4 cP� 0 w �.y Y IN PA' ^ CFPS #1473 r v Cn o r - U H W Z U > Lo W W a) WUV U) J � d H O U = U > a U N �e000a Z >- W Il IX m O mLuWF-H ww� a O � Z W J Wa. 0 xww0sx a 0IxcnJa 0 REVISION RECORD DATE / DESCRIPTION RECEIVED Feb 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2023-0011 DATE: 02/03/2023 PROJECT NAME THIRD FLOOR ----------- A --------------------------------------------------- THIRD FLOOR0) LLJ z o - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C� 00 J a) WLUQ LF LF LF LF A LF LF LF � =zC/)� c FACP-N1 •004 EOL RPS•N2.007 RPS•N2.006 RPS�N2.005 RPS•N2.004 RPS•N2.003 RPS412.002 RPS�N2.001 W A L1 -DO04 L1 •DO05 WP 135° 1Q 35° 0 = Z SECOND FLOOR -_ SECOND FLOOR Q m a O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _------------------------------------------------- NEW FACP AES Q � a FIRE ALARM LV CONTROL PANEL 3Z Z02 Z02 Z02 Z02 � 7PS Z01 DFZ01 01 Z01 Q r, rA a r, FACP +A 1 •003 FACP •N 1 •002 FACP HIV 1 •001 v 15cd 15cd 15cd c-15 0DAMPECIRCUIIT D 120V U u u U w Z Z Z Z Z U U SHEET TITLE F S AIM 2 AIM 2 AIM 2 AOM AIM 2 S S AOM AOM AOM AOM P P P FACP PULL FACP SMOKE L1 +AO02 L1 •M004 L1 •M006 L1 •M008 LVL 1 ELEV L1 •M010 LVL 1 ELEV L1 •M011 L1-M012 L1 •M013 L1 •M014 FIRE ALARM L1 0001 E1 •DO01 WET WF DRY WF LOW AIR L1 •M009 LOBBY SMOKE ELEV DH MACH RM SMOKE PRIMARY ALTERNATE HAT DAMPER BATTERY CALCULATIONS L1 -M1003 L1 •M005 L1 •M007 BACKFLOW L1 •DO02 L1 -DO03 & WET TMPR DRY TMPR PIV SINGLE LINE RISER WET SYS DRY SYS DIAGRAM FIRST FLOOR FIRST FLOOR SHEET NUMBER --------------------------------------------------------------------------------------------------------------------------------------- SINGLE LINE RISER DIAGRAM FA 10