APPROVED FIR2022-0114+Fire_Alarm_Plan+11.7.2022_9.48.05_AM+3206292OPERATIONAL MATRIX SYSTEM OUTPUTS Required Fire Safety Control System Actions Central Station FACP Annunciation c �o m y` r r o p w co Co 40 Q `yam u 0 o A Coo F 0� F !q� Q gym` a� pF F 3 0 �•o' 2° wp `0 �p �p & d .Q Qm . Oi o o ° 4 a io a a a co A` V{ .0 v.. Ir c c c u u u gym aim aim aim � � y� QQQ QQo SYSTEM INPUTS JAIJBICIDIE F I G I H I I I J 2 1 Manual Fire Alarms 1 Q 2 FACP Smoke Detector ♦ ♦ ♦ ♦ ♦ 2 Q3 Sprinkler Waterflow 3 4 Unused 4 5 Sprinkler Tamper 5 W 6 Sprinkler Backflow 6 �7 Unused 7 $ Unused 8 9 Fire Alarm AC Power Failure 9 J10 Fire Alarm System Low Battery 10 m 11 Open Circuit 11 0 12 Ground Fault 12 13 Notification Appliance Circuit Short 13 14 Transmitter Trouble 14 IAIBICIDIEIFIGIHIIIJI VICINITY MAP Lynnwood Edmonds Esperance 104 r I ABBREVIATIONS USED IN THE DRAWING AIM ADDRESSABLE INPUT MODULE cd CANDELA D DETECTOR EOL END OF LINE FACP FIRE ALARM CONTROL PANEL IBC INTERNATIONAL BUILDING CODE IFC INTERNATIONAL FIRE CODE L1 SLC LOOP 1 M MODULE N 1 NAC #1 N2 NAC #2 Q Ilntlake rerrace Lake FO-Irest-F t i 523 =7V L,AKOITY 7/ NAC NOTIFICATION APPLIANCE CIRCUIT NEC NATIONAL ELECTRICAL CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION ntc NOT TO SCALE RIPS REMOTE POWER SUPPLY SLC SIGNAL LINE CIRCUIT WP WEATHERPROOF ZN ZONE BF BARRIER FREE (ADA) PAI-DIADOSE HE SHUS � OLDS A �0�[� A�a��10�1��a��a�0 00K EDMDHDS9 �WA L DEVICE SYMBOL I QTY. MANUFACTURER PART NO. I DESCRIPTION FIRE ALARM HEAD -END EQUIPMENT FACP 1 GAMEWELL GWF-7075 ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL, RED AEs 1 AES 7707-88—ULP WIRELESS COMMERCIAL FIRE ALARM COMMUNICATOR Doc 1 HONEYWELL GW—FAD FIRE ALARM DOCUMENT CABINET W/ USB TSP 1 ASCO MODEL 175 TRANSIENT SUPPRESSION MODULE 1 ASCO PCB1B TRANSIENT SUPPRESSION MODULE BASE 2 DURACELL 12VDC, 8AH BATTERIES FOR FIRE ALARM CONTROL PANEL 2 DURACELL 12VDC, 8AH BATTERIES FOR REMOTE POWER SUPPLY 1 DURACELL 12VDC, 12AH BATTERY FOR AES 2.0 RADIO FIRE ALARM INITIATION DEVICES O 3 GAMEWELL ASD—PL3 ADDRESSABLE, PHOTO, DET. P 3 GAMEWELL B300-6 BASE 3300-6, BASE FOR ADDRESSABLE DETECTORS O 4 GAMEWELL ATD—L3R ADDRESSABLE 135"F ROR HEAT DETECTOR 135" 4 GAMEWELL B300-6 BASE 3300-6, BASE FOR ADDRESSABLE DETECTORS ❑F 1 GAMEWELL MS-7ASF ADDRESSABLE PULL STATION AIM 2 4 GAMEWELL AMM-21F ADDRESSABLE DUAL MONITOR MODULE A0"^ 5 GAMEWELL AOM-2RF ADDRESSABLE RELAY MODULE FIRE ALARM NOTIFICATION DEVICES LF 14 SYSTEM SENSOR HWL—LF L—SERIES , LOW FREQU. HORN, WALL, WHITE 2 SYSTEM SENSOR PC2WL HORN/STROBE, CEILING, WHITE 1 SYSTEM SENSOR SCWL STROBE, CEILING, WHITE WP 1 SYSTEM SENSOR P2RK HORN / STROBE, WP, WALL, RED FIRE ALARM DEVICES BY OTHERS g1 BY OTHERS BY OTHERS WETFLOW SWITCH DF 1 BY OTHERS BY OTHERS DRYFLOW SWITCH PS 1 BY OTHERS BY OTHERS GENERIC LOW AIR PRESSURE SWITCH 2 4 BY OTHERS BY OTHERS TAMPER SWITCH Plv 1 BY OTHERS BY OTHERS POST INDICATOR VALVE SITE PLAN �s a a� W U J a F- ti 9L PARADISE HEIGHTS BUILDING A G� 546 PARADISE LANE EDMONDS, WA. 98020 ANNUNCIA R OUTDOOR HORN/STROBE RISER ROOM '3TNwAysw �C �G Fob oti os 11-29-2022 PLAN REVIEW NOTE: APPROVED WITH CONDITION: CONDITION: INSTALL ONE EXTERIOR STROBE NEAR RISER ROOM. THIS WILL BE IN ADDITION TO THE CURRENTLY LOCATED HORN/STOBE. DFM BURT 4" MIN 12" MA) HEAT DETECTOR A/C SUPPLY OR RETURN DIFFFUSER PENDANT MOUNTED- AUDIBLE/VISUAL APPLIANCES 6" MIN. --1 36" MIN. I AUDIBLE/VISUAL AUDIBLE -ONLY REMOTE ALARM CEILING MOUNTEDJ/CEILING MOUNTED NEVER AND/OR VISUAL ❑ APPLIANCES INDICATOR SMOKE/HEAT AUDIBLE/VISUAL HERE ONLY APPLIANCE o 0 DETECTOR APPLIANCES WALL -MOUNTED HEAT DETECTOR DOOR WIDTH T LESS 3L-1 6" FSA MAGND TIICR �0 30' MAX FACP SYSTEM 17 HOLDER AFF DOCUMENTS 82 -96" 82-96 MIN. 10' MAX 30' MAX TO LOWEST WHERE CEILING AFF ^ AFF PART OF LENS HEIGHT ALLOWS IL(J2�� 5' MAX. 66" TO 66" TO 66" TO FROM EXIT TOP OF TOP OF TOP OF FSA FACP CABINET MANUAL PULL //FLOIORED STATION NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST POINT OF DETECTOR 2" MAX WALL -MOUNTED SMOKE DETECTOR SIDE WALL WALL HEET INDEX SHEET # SHEET DESCRIPTION FA 0.0 FIRE ALARM INSTALLATION DETAILS FA 1.0 FIRST & SECOND FLOOR FIRE ALARM PLAN FA 2.0 THIRD FLOOR FIRE ALARM PLAN, ENLARGED SPRINKLER RISER ROOM & ELEVATOR MACHINE ROOM FA 3.0 BATTERY / POINT TO POINT VOLTAGE CALCULATIONS & SINGLE LINE RISER DIAGRAM SCOPE OF WORK : FIRE ALARM INSTALLATION PER PLAN FOR A NEW FULLY SPRINKLED 3-STORY RESIDENTIAL BUILDING, WITH ONE LEVEL BEING GARAGE. INSTALLATION OF (1) ADDRESSABLE FACP, (1) REMOTE POWER SUPPLY, (1) AES RADIO COMMUNICATOR, (1) FIRE ALARM DOCUMENT CABINET, (3) ADDRESSABLE SMOKE DETECTORS, (1) ADDRESSABLE PULL -STATION, (4) ADDRESSABLE HEAT DETECTORS, (1) WET SPRINKLER SYSTEM MONITORING (THAT INCLUDES A WATERFLOW, TAMPER, BACKFLOW AND PIV), (1) DRY SPRINKLER SYSTEM MONITORING (THAT INCLUDES A DRYFLOW, TAMPER AND LOW AIR PRESSURE SWITCH), (1) ELEVATOR RECALL SYSTEM, AND (17) BUILDING NOTIFICATION DEVICES. NTACTINF OWNER FIRE ALARM CONTRACTOR REFENT CONSTRUCTION, INC FIRE PROTECTION INC 7305 SOUNDVIEW DRIVE 17410 ASH WAY, SUITE 8 EDMONDS, WA 98026 LYNNWOOD, WA 98037 CONTACT : ROB MICHEL CONTACT : DAVID MOW PHONE 206.930.2445 PHONE 425.290.9600 EMAIL RWMICHEL1@ME.COM EMAIL DAVID@FPISEATTLE.COM CODE INFORMATION AUTHORITY HAVING JURISDICTION: CITY OF EDMONDS BUILDING CODE: INTERNATIONAL BUILDING CODE, 2015 EDITION FIRE CODE: INTERNATIONAL FIRE CODE, 2015 EDITION MUNICIPAL CODE: CITY OF EDMONDS BUILDING USE AND OCCUPANCY: R-2 (FULLY SPRINKLED) STANDARDS: NFPA-70 (NEC), NFPA-72, IBC, IFC, & WAC 51-50 CLASSIFICATION OF SUPERVISING STATION: REMOTE SUPERVISING STATION NAME OF SUPERVISING STATION: STANLEY SECURITY, INC TAX PARCEL NUMBER: 27032500302600 INSTALLATION NOTES 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 2. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. 3. CABLE ROUTING SHOWN ON DRAWINGS IS FOR INTENT. EXACT ROUTING TO BE COORDINATED WITH OTHER TRADES IN THE FIELD. SEE SPECIFICATIONS AND DRAWING NOTES FOR ACCEPTABLE INSTALLATION METHODS. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES. 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. 6. POWER -LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NON -POWER LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NON -POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 7. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION EQUIPMENT. WHERE INSTALLED EXPOSED, CABLES SHALL BE ADEQUATELY SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR, IT SHALL BE RUN IN RACEWAY. 8. VERIFY ALL CEILING HEIGHTS AND CEILING TYPES WITH CONTRACTOR DUE TO NOT HAVING A LOT OF INFORMATION TO WORK WITH AND BUILDING THE SCHEMATICS OURSELVES. 9• SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED 100%. 10. WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME WHETHER THEY ARE IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THE FLASH OF THOSE STROBES SHALL BE SYNCHRONIZED (NFPA-72, SECTION 18.5.4.3.2(3) & (4). 11. THE MEANS OF SIGNAL TRANSMISSION TO THE REMOTE SUPERVISING STATION SHALL BE VIA THE FACP'S ONBOARD DACT AND A UL LISTED AES WIRELESS RADIO COMMUNICATOR. 12. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). ALL INITIATING DEVICES AND DEVICES CONTAINING EOL'S SHALL HAVE A PHYSICAL LABEL IDENTIFYING THE DEVICE'S ADDRESS / END OF LINE RESISTOR. 13. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD DRAWINGS OTHERWISE REFERRED TO AS ("AS -BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM DOCUMENT CABINET NEXT TO THE FACP (NFPA-72 10.18.2.3). 14. PRIOR TO CALLING FOR INSPECTION, THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE SYSTEM HAS BEEN INSTALLED, TESTED, EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE APPROVED PLANS. THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN NFPA-72 RECORD OF COMPLETION (NFPA-72 10.18.2.1.1). THE COMPLETED RECORD OF COMPLETION ALONG WITH THE AES RADIO TABLE REPORT SHALL BE PROVIDED TO THE AHJ INSPECTOR PRIOR TO REQUESTING A FIRE FINAL INSPECTION (NFPA-72 10.18.2.1.2.4). FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM vsOTI_ cT,�� n r� NFPA^ #14T3 v rn *k N L: W>_ 0 U H W Z U w W �W°' U ��a Cn 0 U = a�co 0 U � d V J N J a U p 0 o Z W - W 0 �FCOo m W J Q 0 �W� a. 0 �wco_ja o REVISION RECORD DATE / DESCRIPTION FI R2022-0114 RECEIVED Nov 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 10/37 /2022 PROJECT NAME Cn = LV Q O N 00 (' Q J CD LV = (' Z LV Q LU in 0 � a m 0 Q a LO Z W SHEET TITLE I FIRE ALARM PROJECT DETAILS SHEET NUMBER I FA OmO rAi CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. (f2/Mft) DESCRIPTION A 14/4 FPLR 14 3.07 NAC : NOTIFICATION APPLIANCE CIRCUIT U 18/4 FPLR 18 7.77 SLC :SIGNALING LINE CIRCUIT Z 18/2 FPLR 18 7.77 IDC : ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) 8-- N N FIRST FLOOR PLAN � SCALE: 1 /8" = 1' Fire Alarm Device Identification (SLC) ADDRESSABLE DEVICES NOTIFICATION DEVICES CIRCUIT CANDELA DEVICE TYPE DEVICE ADDRESS F NAC CIRCUIT # DEVICE # �`7 F— SLC • D005 O N1. 001 ;) 15 CD LF CONDITION: INSTALL ONE EXTERIOR STROBE NEAR RISER ROOM. THIS WILL BE IN ADDITION TO THE CURRENTLY LOCATED HORN/STOBE. 6-- Q INSTALLATION KEY NOTES # KEY NOTE 1D A DEDICATED 120VAC POWER CIRCUIT IS REQUIRED FOR THE NEW FIRE ALARM PANEL. ® A DEDICATED 120VAC POWER OUTLET IS REQUIRED FOR THE AES RADIO COMMUNICATOR, CAN USE FACP CIRCUIT. ® A NEW DOCUMENT ENCLOSURE. ® VERIFY LOCATION OF ELEVATOR DOOR HOLDER AND POWER FOR SAID DOOR HOLDER. ® FIELD VERIFY FIRE SPRINKLER DEVICE LOCATIONS. © TRANSIENT SUPPRESSION MODULE FOR PROTECTING WIRING GOING OUTSIDE. 0 OUTDOOR DEVICE TO BE EASILY SEEN ON APPROACH FOR FIRE DEPARTMENT. ® HEAT DETECTOR USED FOR ELEVATOR RECALL DUE TO CLOSE PROXIMITY TO THE UNIT KITCHEN. Q Q N SECOND FLOOR PLAN � SCALE: 1 /8" = 1' FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM vsOTI_ cT,�� n r� HFPA^ CFPS #14T3 N 00 p � p � p *k N _u a W>_ 0 U I- W Z U W W W U j aCn 0 U = co 0 VJ N J a U p 0 o Z W W �ou-CO° CO W J Q Z W U 2 W � a o 5; aWco -jlox o REVISION RECORD DATE / DESCRIPTION FI R2022-0114 RECEIVED Nov 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 110/31/2022 PROJECT NAME Cl) = W Q o N Go (' Q J CD LV = (' Z LV C Q uj Cl)0 0 0 Q Q LO CO Z W SHEET TITLE FIRE ALARM FIRST & SECOND FLOOR PLAN SHEET NUMBER FA 1.0 a-- (K)-- (D Q Q N THIRD FLOOR PLAN � SCALE: 1 /8" = 1' CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. f�/M ft) ( DESCRIPTION A 14/4 FPLR 14 3.07 NAC : NOTIFICATION APPLIANCE CIRCUIT U 18/4 FPLR 18 7.77 SLC :SIGNALING LINE CIRCUIT Z 18/2 FPLR 18 7.77 IDC : ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) Fire Alarm Device Identification (SLC) ADDRESSABLE DEVICES NOTIFICATION DEVICES CIRCUIT CANDELA DEVICE TYPE ADDRESS NAC CIRCUIT # DEVICE # F F—DEVICE [- SLC • D005 O N1. 001 U ; ;( 15 CD LF INSTALLATION KEY NOTES qp # KEY NOTE 10 A DEDICATED 120VAC POWER CIRCUIT IS REQUIRED FOR THE NEW FIRE ALARM PANEL. ® A DEDICATED 120VAC POWER OUTLET IS REQUIRED FOR THE AES RADIO COMMUNICATOR, CAN USE FACP CIRCUIT. ® A NEW DOCUMENT ENCLOSURE. 4Q VERIFY LOCATION OF ELEVATOR DOOR HOLDER AND POWER FOR SAID DOOR HOLDER. © FIELD VERIFY FIRE SPRINKLER DEVICE LOCATIONS. © TRANSIENT SUPPRESSION MODULE FOR PROTECTING WIRING GOING OUTSIDE. OUTDOOR DEVICE TO BE EASILY SEEN ON APPROACH FOR FIRE DEPARTMENT. ® HEAT DETECTOR USED FOR ELEVATOR RECALL DUE TO CLOSE PROXIMITY TO THE UNIT KITCHEN. Ll *M002 Ll *M003 WET SYS Ll *M004 Ll *M005 DRY SYS Ll oM006 Ll oM007 LOW AF / PN Ll eMOO8 Ll oM009 BACKFLOW Ll eM01 I PRIMARY Ll *M01 2 ALTERNATE FArp �l\ E L1,*D001 ENLARGED FIRE SPRINKLER ROOM \,J SCALE: 1/4" = 1' 2 ENLARGED ELEVATOR MACHINE ROOM SCALE: NTS Z02' PIV� IF FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM vgoTEcT, n r� NFPA^ #14T3 CNI 00o �o *k N =� a w>_ ❑ U t- W Z > U W CI W U Cn a ❑ U = Q u U U 0 d V J N J Q U p ❑ o Z�W�W �oC'�° 0 m W J Q W Z W U 2 W a. ❑ Q�Q 5; aW<W a wo ❑�cnJa ❑ REVISION RECORD DATE / DESCRIPTION F I R2022-0114 RECEIVED Nov 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 10/31 /2022 PROJECT NAME Cl) = W Zo Q00 CD CD W = (' Z LV Q Lu Cl) 0 aLnW -_QC m 0 Q a Z SHEET TITLE FIRE ALARM THIRD FLOOR PLAN ENLARGED ROOMS SHEET NUMBER FA 2mO PANEL FACP (GWF-7075) BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) PANEL COMPONENTS QTY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL 1 GWF-7075 Main Board Intelligent Fire Alarm Control Panel Main Board 0 0 0 0 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) AIM 2 4 AMM-21F Addressable Dual Monitor Module 0.0007 0.0028 0.0007 0.0028 A0A^ 5 AOM-2RF Addressable Relay Module 0.0003 0.0015 0.0003 0.0015 FACP•L1 OP 3 ASD-PL3 / B300-6 BASE Addressable, Photo, Det. 0.0003 0.0009 0.0003 0.0009 O 135• 4 ATD-L3R / B300-6 BASE Addressable 1357 RoR Heat Detector 0.0003 0.0012 0.0003 0.0012 F❑ 1 MS-7ASF Addressable Pull Station 0.0003 0.0003 0.007 0.007 M1 WP 1 P2RK Horn/Strobe,WP,Wall , Red 110cd 0 0 0.221 0.221 FACP•N 1 1 PC2WL Horn/Strobe, Ceiling, White 15cd 0 0 0.071 0.071 1 PC2WL Horn/Strobe, Ceiling, White 75cd 0 0 0.143 0.143 ;C11 1 SCWL Strobe, Ceiling, White 15cd 0 0 0.041 0.041 FACP•N2 LF 14 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0 0 0.111 1.554 TOTAL STANDBY (A) 0.0067 TOTAL ALARM (A) 2.0434 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.0067 24 1 0.16 SECONDARY ALARM LOAD (A) 2.0434 0.08 1 0.17 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 0.33 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 0.4 PROVIDE (2) 12V 7AH BATTERIES 'BATTERY BOX SIZE CAPACITY NOT SPECIFIED. REFER TO MANUFACTURER DOCUMENTATION. THIRD FLOOR SECOND FLOOR BATTERY CALCULATIONS RPS•N2.008 RPS-N2-009 RIPS •N2.010 RPS•N2.011 RPS•N2.012 RPS-N2-013 RPS-N2-014 EOL u- u u u- u- u u- FACP •N1 •004 EOL RPS•N2.007 RPS•N2.006 RPS•N2.005 RPS•N2.004 RPS•N2.003 RPS•N2.002 RPS•N2.001 01 110cd WP FACP •N1 •003 FACP •N1 •002 FACP •N1 •001 15cd 75cd 15cd FACP N1 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.68 Min. Operational Voltage: 16 End Of Line Voltage: 19.72 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 3.34 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.476 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 313 Spare Current (A): 2.024 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 1.921921 Spare Current (A) Percent: 80.96 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (0) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent FACP•Nl-001 PC2WL Horn/Strobe, Ceiling, White 15cd 0.071 0.476 110 0.672457 0.32 20.08 0.32 1.57 % FACP•Nl-002 PC2WL Horn/Strobe, Ceiling, White 75cd 0.143 0.405 68 0.415707 0.17 19.91 0.49 2.39 % FACP•Nl-003 SCWL Strobe, Ceiling, White 15cd 0.041 0.262 36 0.219757 0.06 19.85 0.55 2.68 % FACP•N1.004 EOL P2RK Horn/Strobe,WP,Wall , Red 110cd 0.221 0.221 100 0.614 0.14 19.72 0.68 3.34 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) FACP N2 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 2.1 Min. Operational Voltage: 16 End Of Line Voltage: 18.3 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 10.31 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 1.554 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 366 Spare Current (A): 0.946 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 2.247393 Spare Current (A) Percent: 37.84 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (0) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent FACP•N2.001 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 1.554 75 0.4605 0.72 19.68 0.72 3.51 % FACP•N2.002 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 1.443 19 0.115929 0.17 19.52 0.88 4.33 % FACP•N2.003 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 1.332 2 0.011 0.01 19.5 0.9 4.40 % FACP•N2.004 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 1.221 31 0.192444 0.23 19.27 1.13 5.55 % FACP•N2.005 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 1.11 30 0.183828 0.2 19.06 1.34 6.55 % FACP•N2.006 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.999 28 0.174207 0.17 18.89 1.51 7.40 % FACP•N2.007 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.888 23 0.13893 0.12 18.77 1.63 8.01 % FACP•N2.008 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.777 25 0.1535 0.12 18.65 1.75 8.59 % FACP•N2.009 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.666 23 0.138922 0.09 18.55 1.85 9.05 % FACP•N2.010 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.555 28 0.173552 0.1 18.46 1.94 9.52 % FACP•N2.011 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.444 30 0.181359 0.08 18.38 2.02 9.91 % FACP•N2.012 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.333 32 0.195972 0.07 18.31 2.09 10.23 % FACP•N2.013 HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.222 2 0.010941 0 18.31 2.09 10.25 % FACP•N2.014 EOL HWL-LF L-Series , Low Frequ. Horn, Wall, White 0.111 0.111 19 0.116309 0.01 18.3 2.1 10.31 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (4/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) NEW FACP AES FIRE ALARM CONTROL PANEL 3z 0 � H DEDICATED 120V G ~� 20 AMP CIRCUIT POINT TO POINT VOLTAGE DROP CALCULATIONS L1 -D006 L1 •DO07 135' 135• --------------------------------------------------- THIRD FLOOR L1 -D004 L1 •DO05 135• 135• -------------------------------------------------- SECOND FLOOR ^ Z02 Z02 PIVZ02 Z02 (d�a Z01 Z01 Z01 Z01 DF PS D� ALT � � - 00 P m 2 m 2 M 2 M 2 P P FACP PULL FACP SMOKE L1 •M002 L1 •M004 L1 •M006 L1 •M008 LVL 1 ELEV L1 •M010 LVL 1 ELEV L1 •M011 L1 •M012 L1 •M013 L1 •M014 L1 •M001 L1 •DO01 WET WF DRY WF LOW AIR L1 •M009 LOBBY SMOKE ELEV DH MACH RM SMOKE PRIMARY ALTERNATE HAT DAMPER L1 •M003 L1 •M005 L1 •M007 BACKFLOW L1 -D002 L1 •DO03 WET TMPR DRY TMPR PIV WET SYS DRY SYS �WA A r, r IF FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM #14T3 vrn �o *k N =� a u: W>_ ❑ Z LU U W �Wo' CO IY UCn Lu�a ❑ U = Q � co U U 0 V a. J N J UJ Q U p ❑ o z>- WIW >- Uj >- m W J a Z U W ❑ Q�Qw�*ka aww0sIx a ❑wco-1a ❑ REVISION RECORD DATE / DESCRIPTION FI R2022-0114 RECEIVED Nov 08 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 10/37 /2022 PROJECT NAME Cl) = L U Q O N 00 CD LV = (' Z LV C Q �L/U� V� 0 IL 0 Q tr) Z W SHEET TITLE I FIRE ALARM BATTERY CALCULATIONS SINGLE LINE RISER DIAGRAM FIRST FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FIRST FLOOR SINGLE LINE RISER DIAGRAM SHEET NUMBER I FA 10