BLD2024-0654_Manufacturer_Specifications_and_Installation_Instructions_5.15.2024_7.26.11_AM_4257658TIGE Solo
gn runciency tovnc
• 439 Stainless Steel Fire Tube Heat Exchanger
• ASME Stamped Heat Exchanger
95% AFUE
• Turndown ratios up to 5.5:1
• Low Pressure Drop with Proven Performance
• 2" to 4" Venting
Multiple Venting Termination Options
• Low NOx - 2012 SCAQMD Certified
• 7 Models from 80 to 399 MBH
• 2 Year Control & Blower Warranty
so 10 Year Limited Heat Exchanger Warranty
• 5 & 10 Year Extended Warranty Options
Featuring ACVMax Control with:
CD
0 000 0 !
0 i
• 60 Second Set-up Based on Former TriMax Platfoi
• Integrated Cascade Function for up to 6 Boilers
• Two Reset Curves / Set Points
• Multiple Zone Control
• Multiple Circulator Control
Q@ E AS
ME
C
z uas t
ACV -Max Control
60 Second Set -Up
• Choose from 6 standard heating applications to
set up the boiler in 60 seconds or less.
• Finned Tube Baseboard • High Mass Radiant
• Cast Iron Baseboard • Low Mass Radiant
• Radiators • Fancoil
• Preconfigured for indirect hot water applications
Integrated Cascade
Joins up to 6 boilers: Master boiler automatically recognizes linked boilers: Meets simultaneous DHW &
Space Heating calls: Full Parallel Modulation: Automatic Duty Cycling.
Multiple Zone Control
• Accepts 2 space heating calls with independent outdoor reset curves
• Simultaneously heat dual temperature heating systems with built-in mixing valve control
• Manage up to 2 space heating zones and 1 DHW zone without an external zone control panel
Multiple Circulator Control
• Presets allow quick configuration of 4 circulator outputs for the application
• Each circulator output is fully configurable for custom applications
Intelligent Troubleshooting
Describes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for
24 hours.
Next Generation Fire Tube Heat Exchanger
High Water Content
• Provides stable temperature control
• Low sensitivity to water flow
• Reduces short cycling
• Adapts to large or small heating loads
Unique Geometry
• Designed for maximum reliability with low thermal stress
• Improved water flow for maximum heat transfer
• 439 Stainless Steel with titanium for corrosion resistance
• Polypropylene condensate pan and flue resists corrosion
Reliable Low Maintenance Design
• Self cleaning design washes away combustion debris
• 12 year history of reliable performance
• High performance burner design
• Low pressure drop allows piping directly to the system
• ASME Stamped NO
Prestige Solo
Test Ports in both Flue
and Air Connections —
Cast Aluminum burner plate with
integrated angled sight glass —
Single piece gasket and —
insulation to reduce
parts & ease maintenance
Industry Leading
Fire tube heat /
exchanger
Swing Out Electrical
Panel Permits
quick access to
boiler internals
Integrated Check Valve - To eliminate
flue gas blow back in negative pressure locations
Offset Blower with quick
connect to minimize heat
load and ease maintenance
Sound Attentuated
Air Inlet
Polypropylene Flue and Condensate Pan
Eliminates corrosion from condensate
ACVMax Display Module
The Widest Range of Venting and Termination Options
Venting
- 2", 3", and 4" diameters depending on model
- PVC,CPVC, SS and Polypropylene materials
- Flexible Polypropylene for chimney chases
- Concentric (399 only) or twin pipe
- Extended vent lengths up to 100 feet
-Common Vent for multiple boilers (399 only)
Terminations
- Traditional PVC/CPVC/PP/SS piping elbows
- Flush -mount PVC for twin pipes
- Flush -mount Stainless Steel for twin pipes
- Single hole Concentric Termination for twin pipes
- Horizontal Concentric Termination (399 only)
- Horizontal and Vertical Common Vent Terminations (399 only)
Performance Specifications Connections/Dimensions/Data
Boiler
Input
OOE
Healing
Turndovrn
Nel AHRI
\Valer
I.lodel
Fuel
Modulation
AFUE
CMBHIy
Rail.
Raiing
Volume
MBH
1.1 BH
Gel.
Sob 80
Natural
16 to
95%
72,000
5.0 : 1
63,000
2.1
Propane
80
Sob l to
Natural
20 to
95%
99,000
5.5 : 1
86,000
2.1
Propane
110
Sob 155
Natural
27.8 to
95%
138,000
5.5 : 1
120,000
4
Propane
153
Sob 175
Natural
30.9 to
95%
154,000
5.5 : 1
134,000
5.3
Propane
170
Sob 250
Natural
43.6 to
95%
218,000
5.5 : 1
190,000
4.5
Propane
240
Sob 299
Natural
72.5 to
95%
272,000
4.1 : 1
237,000
7.4
Propane
299
S010399
Natural
72.5to
95.1%'
379,000
5.5:1
330,000
7.4
Propane
399
'Thermal Efficiency
Boller
Model
Supply/Return
Connectlons
Gas
Connections
Vent/Alr
Diameter
Olmenslons
GXWxH
Weight
Lbs
801080
1 "
1 /2"
3"
17-5/16" x 19-314" x 36-9/16'
103
S010110
11.
1 /2"
3-
175/16' x 19-3/4' x 36-9/16'
103
Solo 155
1-1/4"
3/4"
3"
175116" x 19-3/4' x 36-9/16"
118
Solo 175
1-1/4"
3/4"
3"
17-5/16" x 19-3/4' x 36-9116"
128
Solo 250
1-1/4"
3/4"
3"
17-5116' x 19-3/4" x 36-9116"
140
Solo 299
1-1/2"
1 "
4"
23-5/8' x 24-7/8' x 39-3/8'
210
Solo 399
1-1/2"
1"
4"
23-5/8' x 24-7/8" x 39-318'
216
Couple to Industry Leading Indirect Water Heater Family
Tank in Tank Design (No Coils - Maintenance Free)
Boiler 1st Hour Peak
Output Recovery ContinuousLal/10rni
Flow
Model BTU/hr Flow (gal.)
(gal.)
SMART FAMILY WITH 2" INSULATION
Smart 30
87,000
140
115
40
Smart 40
112,000
180
150
50
Smart 50
140,000
220
185
65
Smart 60
270,000
410
360
100
Smart 80
300,000
460
400
125
Smart 100
337,000
525
450
150
Smart 120
420,000
650
560
190
UUM1-UHI I-AMILY WIIH 1-1/2" 1NSULAIIUN
Comfort 45 90,000 149 127 1 44
Comfort 55 118,000 185 157 1 55
N
• Unparalleled performance allows 25-50% smaller size than competitors
• Fastest recovery - recovery in 30%-40% less time than competitors
• Stainless Steel construction
• Residential Smart tanks have limited lifetime warranty
0
• Comfort Tanks have 10 year limited warranty
• 7 sizes in Smart family
U)
• 2 sizes in Comfort family
s
N
A
Triangle Tube reserves the right to make product changes or Improvements at any time without notice.
Triangle Tube . One Triangle Lane . Blackwood NJ 08012 • www.triangletube.com
p 856.228.8881 f 856.228.3584