Loading...
APPROVED ENG STM RESUB1 BLD2021-0092+Structural Calcs+3.1.2021_8.29.44_AM+2067938�S SITE STRUCTURES A Division of Kosnik Engineering, Pt Main Street Commons Storm Water Detention Vault Edmonds, Washington Structural Calculations Project No. S-21-004 First Issue 01-22-2021 Second Issue 02-28-2021 10505 19T" Ave SE, Suite B, Everett, WA 98208 ♦ (425) 357-9600 (phone) ♦ e-mail: dan@kosnik.com Main Street Commons Storm Water Detention Vault Project No. S-21-004 STRUCTURAL CALCULATIONS INDEX Design Criteria HC Plank Lid Review Vault Wall & Foundation Review Sheet 01 - 03 04-07 08 - 15 DESIGN CRITERIA Code: Permitting Soil Cover: Main Street Commons Storm Water Detention Vault 2015 IBC City of Edmonds, Washington 1.2ft min to 1. S ft max. Lid Loading: 150 psf uniform live load HS20 truck wheel loading Uniform live load does not act concurrently with truck wheel loading. Foundation Design: Foundation design is based on the following values provided by Pan Geo in their report dated 11- 14-2018 Allowable Bearing Pressure: 4,000 psf Lateral Earth Pressures on Vault Walls ( drained level backfill condition ): Active: At Rest: Seismic Addition: Saturated Soil Density: 35 pcf EFW 45 pcf EFW E = 7H psf Uniform 125 pcf Material Requirements: Rebar: Grade 60 Concrete: f c= 4000 psi walls, footings and grade slab Lid: Pre -cast, Pre -stressed Hollow Core Plank 12-1/2" thick. SITE STRUCTURES Project FRONT AXEL: REAR AXEL # 1: REAR AXEL #2: HS20-44 725000LBS 8,o00LBS >> 325000LBS 32500-OLBS sheet date ZO-1 prj . no. noa i , • ... ....... .......... i •r 7TY.- �. 8. ]b H*44 32,00 `1b 32,O W-lb -axle. 1011--- 0he ,�y ��y �y�' H'-buck V a brio-%e a spo ing which 'o!Wft ,rW m m.. 5.tg .. For d igfl -!Oa.f cenierlao of wheel to. I ft from curb: G/ r � HS 20 - 44 TRUCK LIVE LOAD ON WALLS K R 16 6, 16 '� o E � � f �.• � .•� • �� • � �. �� w � �� a � �. • ... • .. .- � .. ... . � '• ! � • � • • � • � • �. �� f� 1l'_-2i�-UO�' _ AUERAG� UNIFORM HORIZONTAL LOAD SITE STRUCTURES Project Main St. Commons sheet 10511 19th Ave SE, Suite C date � - Zfj •'Z� Everett, WA, (425)-357-9600 prj. n0. 5-21-004 PRECAST HOLLOW CORE PLANK REVIEW Lid Data Soil Desity 125 pcf Soil Cover depth over lid 1.5 ft Plank design clear span 14 ft Design Uniform Live Load 150 psf Design Superimposed Load 337.5 psf Plank capacity based on uniform superimposed load tables Plank span 28 ft No of tendons 11 Allowable superimposed loads 413 psf Allowable superimposed loads base of design span of 14.25 ft Based on flexural capacity 1595 psf Based on shear capacity 812 psf Plank capacity based on truck load charts Plank span 14.25 ft No of tendons 11 Allowable soil cover without knee -walls 0.5 to 5.2 ft Allowable soil cover with knee -walls 0.5 to 11.5 ft �4 C— 0 000k-e J�� CONCRETE TECHNOLOGY CORPORATION � x,-noq 121/2" HOLLOW CORE SLAB 3'-101/2" DIMENSIONS 611 t11/2" 11 1/z"• • 111/2" 6" FOR DETAILING "/16'� 21/4" , ,.•. • y,• � - � rid• - • - .• ••- •, • - • -• •- • - ` . ; . , . ,; . • _ 1. �;:: :, C', 6 N pJ 4 + N z 17/16" 11 " 111 /2" 111 /2" 11 " 17/1 e" (4'-0" Nominal Width) SPAN -LOAD TABLE ALLOWABLE SUPERIMPOSED* LOAD- in'. pounds per square foot Effective No. of SIMPLE .SPAN In feet . . Prestress 11211 0 28 32 36 40 44 48 ' 52 56 60 (KIPS) STRANDS 70.7 3 78 44 20 77.7 14 126 80 49 26 101.3 5 174 117 78 50 27 124.8 6 221 153 106 70 43 23* 148.4 7 267 186 129 89 59 36 172.0 8 307 216 153 108 74 49 29 195.5 9 343 243 174 125 89 61 40 23* 219.1 10 3781 270 195 142 1.03 73 50 31 242.7 11 4131 297 217 160 117 85 60 40 24* SECTION PROPERTIES (with shear keys grouted) A = 313 in2 Zt = 1019 in3 Zb = 947 in3 w = 84 psf I = 6136 in4 Yt = 6.02 in Yb = 6.48 in NOTES: 1. The values given in this table are based on hollow core slabs without shear reinforcement. Superscripts (1, 2, etc.) following values in the table indicate the number of filled voids required at the ends of slabs to develop the allowable superimposed load. See page 2, "SHEAR" for discussion. 2. Asterisk (*) following values in the table indicate that the total deflection under all loads is greater than U360 but fess than U1.80. 3. Interpolation between values is acceptable: Do not extrapolate values into the blank spaces of the table. 4. These Span -Load Tables are intended as an aid. to preliminary sizing. Sound engineering judgement is required for the application of this information to specific design cases. X�_�40011 (for, -'� 10 Z M LLJ � w6V 121/2" HOLLOW CORE SLAB HS20=44 Number for 2'-0" of at each Filled end Voids of required each slab. 11 Strands Knee �-aCal -ZI I= M 0 14 16 18 20 22 24 26 28 30 32 34 36 38 SIMPLE SPAN (ft) GENERAL NOTES: 1..) A minimum cover depth of six inches OR a three inch thick cast in place concrete topping slab is required. 2.) Simple Span is centerline of bearing to centerline of bearing. 3.) The Knee Wall envelope represents the maximum span and height of soil cover that can be supported by slabs with standard notches for manhole openings, assuming void fill concrete f'c = 3,000 psi. Points falling outside this envelope require knee walls to support the slabs at manhole openings. 4.) Interpolation between strand contours is acceptable. DO NOT extrapolate beyond the bounds of this chart. 5.) Soil cover is assumed to be uniform. 6.) Except as noted, soil cover unit weight is assumed to be 120 pcf. 7.) Minimum span length = 14'-0". 8.) The values shown on this chart are in compliance with IBC 2015 & ACI 318-14. 9.) The Vent Notch envelope represents the maximum span and height of soil cover that can be supported by slabs with 6'/2" standard notches in adjacent slabs to accommodate 12" diameter vents, assuming void fill concrete fc = 3,000 psi. Refer to Detail 3 on page 13 of this brochure for vent notch details. 1/03/17 MANUFACTURERS OF PRESTRESSED CONCRETE • TACOMA, WASHINGTON 7 10 z IL 9 0 a 0 r 8( H LL 6 W O 5 t� J O 4 W UL O I— 3 C' W 2 12'/2' HOLLOW CORE SLAB 1 150 PSF Vent Notch9 Number for 2'-0" of at each Filled Voids end of each required slab. E. IL ONE 11 Stran mom Knee 14 /- 16 18 20 22 24 26 28 30 32 34 36 38 VJ SIMPLE SPAN (ft) GENERAL NOTES: 1.) A minimum cover depth of six inches OR a three inch thick cast in place concrete topping slab is required. 2.) Simple Span is centerline of bearing to centerline of bearing. 3.) The Knee Wall envelope represents the maximum span and height of soil cover that can be supported by slabs with standard notches for manhole openings, assuming void fill concrete fc = 3,000 psi. Points falling outside this envelope require knee walls to support the slabs at manhole openings. 4.) Interpolation between strand contours is acceptable. DO NOT extrapolate beyond the bounds of this chart. 5.) Soil cover is assumed to be uniform. 6.) Except as noted, soil cover unit weight is assumed to be 120 pcf. 7.) Minimum span length = 14'-0". 8.) The values shown on this chart are in compliance with IBC 2015 & ACI 318-14. 9.) The Vent Notch envelope represents the maximum span and height of soil cover that can be supported by slabs with 6'/2"'standard notches in adjacent slabs to accommodate 12" diameter vents, assuming void fill concrete f'c = 3,000 psi. Refer to Detail 3 on page 13 of this brochure for vent notch details. 1/03/17 MANUFACTURERS OF PRESTRESSED CONCRETE • TACOMA, WASHINGTON 9 SITE STRUCTURES Project Main St. Commons sheet: 10511 19th Ave SE, Suite C date: /Ole 1-14 Everett, WA, (425)-357-9600 prj . no. 5-21-004 Vault Walls - Lateral Pressures Review Minimum soil cover depth to top of wall: 2.2 ft Maximum soil cover depth to top of wall: 2.5 ft Wall Height: 7 ft At -Rest soil pressure: 45 pcf EFD Soil pressur in comb w/ seismic: 45 pcf EFD Uniform Addition to At -Rest soil pressure: 0 psf Soil Density: 125 pcf Load Combinations: 1.6 L (soil pressure) + 1.6 L (surcharge/wheel load) 1.6 L (soil pressure) + 1.0 L (seismic) Due to HS20 Truck Loading: 1.2 ft min cover over lid: 130 psf Uniform 1.5 ft max cover over lid: 120 psf Uniform Total Factored Lateral Force: 1.2 ft min cover over lid: 4329 plf 1.5 ft max cover over lid: 4368 plf GpN'j"i1-O(� ,��IIiIJ Due to Uniform Surcharge Load: Uniform surcharge: 150 psf Equivalent lateral force: 54 psf Uniform Total Factored Lateral Force: 1.5 ft max cover over lid: 3629 plf Due to Seismic Activity: r2,� Uniform seismic addition: E = 9.5 H Seismic lateral force: 67 psf Uniform 1 � Total Factored Lateral Force: 1.5 ft max cover over lid: 3490 plf Combined Load Factor: 1.52 SITE STRUCTURES Project Main St. Commons Sheet 10511 19th Ave SE, Suite C date 2 Everett, WA, (425)-357-9600 prj . no. 5-21-004 Design Data W-1 S Soil Density 125 pcf Soil Cover depth to the top of the wall 2.5 ft Ws1 = 112.5 psf Wall height 7 ft Ws2 = 315 psf Soil Pressure EFW 45 pcf Surcharge Information uniform S 1 = 150 psf (on surface of ground) Equiv Ws = 54 psf truck Ws = 120 psf ( on surface of wall ) Critical Design Surcharge pressure = 120 psf (on the surface of the wall) Calculated Design Forces W1= 232.5 F1 = 1627.5 Ibs R top = 1181 Ibs W2= 315 F2 = 1102.5 Ibs R bot = 1549 Ibs M1 = 1424 M total= 2414 ft-Ibs M2 = 990 Wall Reinforcing Wall thickness 8 inches Comp block (a) = 0.36 inches Clear cover 2 inches Depth to CL bar (d) = 5.69 inches Rebar size 5 d-a/2 = 5.51 inches Rebar area 0.31 sq-in Bar spacing 15 inches�' (PMn = 6082 ft-Ibs Rebar strength fy 60 ksi r Conc strength f'c 4000 psi u M = 3863 ft-1 bs Load Factor 1.6 max tension reinforcing spacing: fs = 21434 psi ✓'s = 23.0 in s = 22.4 in Smax = 22.4 in - OK Anchorage at Top of the Wall Ru = 1890 plf #5 hairpins net #5@ 15"o/c #5 hairpins net #5@ 18"o/c Anchorage at Bottom of the Wall Ru = 2478 plf Nominal Shear friction capacity of the footing to wall Dowel 7589 plf (PVn = 6700p1f OVn = 5580p1f Rebar Dowel Size = Dowel Area = Dowel strength fy= Dowel Spacing = Coefficient of friction = 5 0.31 sq-in 60 ksi 15 inches 0.6 smooth surface SITE STRUCTURES Project Main St. Commons sheet 10 10511 19th Ave SE, Suite C date Everett, WA, (425)-357-9600 prj. ri0. 5-21-004 Design Data �/&* t .'jZ�F`r�-ry���" (JiG Soil Density 125 pcf Soil Cover depth to the top of the wall 2.5 ft Ws1 = 112.5 psf Wall height 7 ft Ws2 = 315 psf Soil Pressure EFW 45 pcf Surcharge Information uniform S1 = 0 psf (on surface of ground) Equiv Ws = 0 psf truck Ws = 0 psf ( on surface of wall ) Critical Design Surcharge pressure = 0 psf (on the surface of the wall) Calculated Design Forces W1= 112.5 F1 = 787.5 Ibs R top = 761 Ibs W2= 315 F2 = 1102.5 Ibs R bot = 1129 lbs M 1 = 689 M total= 1679 ft-Ibs M2 = 990 Wall Reinforcing Wall thickness 8 inches Clear cover 2 inches Rebar size 5 , Rebar area 0.31 sq-in Bar spacing 15 inches + Rebar strength fy 60 ksi Conc strength f'c 4000 psi Load Factor 1.6 max tension reinforcing spacing: fS = 14909 ps Anchorage at Top of the Wall Ru = 1218 plf #5 hairpins net #5@ 15"o/c #5 hairpins net #5@ 18"o/c Anchorage at Bottom of the Wall Ru = 1806 plf Nominal Shear friction capacity of the footing to wall Dowel 7589 plf Comp block (a) = Depth to CL bar (d) = d-a/2 = OMn = Mu = s= s= Smax — 0.36 inches 5.69 inches 5.51 inches 6082 ft-Ibs D 2687 ft-Ibs 35.2 in 32.2 in 32.2 in - OK (PVn = 6700p1f OVn = 5580p1f Rebar Dowel Size = Dowel Area = Dowel strength fy= Dowel Spacing = Coefficient of friction = 5 0.31 sq-in 60 ksi 15 inches 0.6 smooth surface SITE STRUCTURES Project Main St Commons sheet: _11 10511 19th Ave SE, Suite C date 2O 2 Everett, WA, (425)-357-9600 prj . n0. 5-21-004 Load Combination 1.2D+1.OE+1.OL+1.6H E_ 67 psf L= 120 psf Total= 187 psf Wall Total Height Force 7.00 ft 1309 Ibs H= 78:71.11, 102 1889 Ibs Total Force 3198 Ibs Factored Load 4331 Ibs Average Load Factor 1.35 SITE STRUCTURES Project Main St. Commons sheet 10511 19th Ave SE, Suite C date Everett, WA, (425)-357-9600 prj. no. 5-21-004 Design Data � (� i�j � � �! 'f` ' � U� '� (�� t000, '�" 104 61 Soil Density 125 pcf Soil Cover depth to the top of the wall 2.5 ft Ws1 = 112.5 psf Wall height 7 ft Ws2 = 315 psf Soil Pressure EFW 45 pcf Surcharge Information uniform S1 = 0 psf (on surface of ground) Equiv Ws = 0 psf truck Ws = 0 psf ( on surface of wall ) Critical Design Surcharge pressure = 187 psf (on the surface of the wall) Calculated Design Forces W1= 299.5 F1 = 2096.5 Ibs R top = 1416 Ibs W2= 315 F2 = 1102.5 Ibs R bot = 1783 Ibs M 1 = 1834 M total= 2825 ft-Ibs M2 = 990 Wall Reinforcing Wall thickness 8 inches Comp block (a) _ Clear cover 2 inches Depth to CL bar (d) _ Rebar size 5 d-a/2 = Rebar area 0.31 sq-in Bar spacing 15 inches V OMn = Rebar strength fy 60 ksi Conc strength f'c 4000 psi Mu = Load Factor 1.35 max tension reinforcing spacing: fs = 25078 psi �"' s = s= Smax — Anchorage at Top of the Wall Ru = 1911 plf #5 hairpins net #5@ 15"o/c #5 hairpins net #5@ 18110/c Anchorage at Bottom of the Wall Ru = 2407 plf Nominal Shear friction capacity of the footing to wall Dowel 7589 plf 0.36 inches 5.69 inches 5.51 inches 6082 ft-Ibs DID 3813 ft-Ibs 18.9 in 19.1 in 18.9 in - OK (PVn = 6700p1f OVn = 5580p1f Rebar Dowel Size = 5 Dowel Area = 0.31 sq-in Dowel strength fy= 60 ksi Dowel Spacing = 15 inches Coefficient of friction = 0.6 smooth surface N ---� ���. � `� l .o. � sue: :..:. �...: .:...�...... - � =..:...: .:._ �..:.��`...:..:..:......�...;._.:...�....',...�...� .:..... � .....�...: .:...; ......,.-�:--............ �...... :..... `�'�` :..: � .....:.. sue►; .. .:..... � .: . - ...:..... � .....:.....:......:... •_ ...... � ..... .... , .....: , �--:... ; � ; . .... �......:.......:. � ..,:. �.: • ,2 ..: � - - ��`dM .... ... :�...; n8 ...� .:�`.:..�:. . -; :.. ..; li9 :...: .:...:...:. :... ..� j i O W ...:...:...:...:...:...:...: ------------------------------------� - � � N ...:...:... �.. � , ... a I O a I '. .. ... .........� . �. . ,....I.. _ I � � Q / . W,.., .,..�...�. . Q ..:._ oQ �': : : ... :_.. O a:..... SITE STRUCTURES Project Main St. Commons sheet 10511 19th Ave SE, Suite C date , Everett, WA, (425)-357-9600 prj. n0. S-21-004 Design Data: Wall Foundation Loads Analysis Soil Desity 125 pcf Per. wall Cell Width Soil Cover over the lid 1.5 ft I nt. wall Cell Width left Plank weight 90 psf Int. wall Cell Width right Uniform Live Load 150 psf Truck Rating HS20-44 Front Axle Load 8000 Ibs Rear Axle #1 Load 32000 Ibs Wall Height 7 ft Rear Axle #2 Load 32000 Ibs Total vehicle wt 72000 Ibs Truck Wheel Load Distribution to Perimeter Wall Foundation 14 ft 7 ft 7 ft Truck Perpendicular to the perimeter wall w/ rear axle #2 directly over wall & distance to axle #1 = 14ft total truck load to wall = 32000 Ibs distribution width = 25 ft Load @ base of wall = 1280 plf Truck Parallel to the perimeter wall w/ one wheel over wall & 2nd wheel on plank (incl axle 1 &2 only ) total truck load to wall = 50286 Ibs calc distribution width = 33 ft Load @ base of wall = 1524 plf Truck Wheel Load Distribution to Interior Wall Foundation Truck Per endicular to the int. wall w/ rear axle #2&#1 centered over the wall 8 dist between axles - 14ft total truck load to wall = 0 Ibs distribution width = 25 ft Load @base of wall = plf Truck Perpendicular to the interior wall w/rear axle #2 directlz overvdll, d d' total truck load to wall = 0 Ibs left plank LoacJ.=se 'all = total truck load to wall = 0 Ibs right plank „ ILp�of wall = distribution width = 25 ft Ince to axle #1 = 14ft 0 plf 0 plf r� Truck Parallel to the interior wall w/ one OFieel r wall & 2nd wheel on plank (incl axle 1 &2 onl total truck load to wall = 3 total truck load to wall = 3 distribution width = Olb plank Load @base of wall = 1108 plf Ibs right plank Load @base of wall = 1108 plf 33 ft Truck Parallel to the lh-terior wall w/ the truck centered over the wall (incl axle 1 &2 onli total truck I to wall = 36571 Ibs distri n width = 33 ft Uniform Live Load distribution to Wall Footings Perimeter Wall 1050 plf Load @ base of wall = 1108 plf SITE STRUCTURES Project Main St. Commons sheet I �% 10511 19th Ave SE, Suite C date 14 100-11,041j Everett, WA, (425)-357-9600 prj. no. S-21-004 Design Data :Wall Foundation Design Allowable Bearing Pressure 4000 psf Per. wall Cell Width 14 ft Rebar strength fy = 60 ksi Int. wall Cell Width left 7 ft Concrete strength = 3000 psi Int. wall Cell Width right 7 ft Soil Desity 125 pcf Plank weight 90 psf Soil Cover over the lid 1.5 ft Wall Height 7 ft Wall Thickness 8 inches Perimeter Wall Footina Design L.F Wu Design live load 1524 plf 1.6 2438.4 plf Soil Cover dead load 1438 plf 1.2 1725 plf Plank dead load 690 plf 1.2 828 plf Wall dead load 700 plf 1.2 840 plf total dead load 2828 plf 3393 plf Total live +dead Load 4352 plf 10. 5831 plf Required Ftg Width 1.09 ft Selected Ftg Width 2 ft Selected Ftg Thickness 12 in Qu = 2916 psf Mu = 648 ft-Ibs at face of wall Vu = 1944 plf at face of wall As regd = 0.02 sq-in/ft phi Vn= 9498 plf � at face of wall Asmin = 0.35 sq-in/ft 1.33 x As regd = 0.02 sq-in/ft Interior Wall Footing Design L.F Wu Design live load 1108 plf 1.6 1772.8 plf Soil Cover dead load 1313 plf 1.2 1575 plf � Plank dead load 630 plf 1.2 756 plf Wall dead load 700 plf 1.2 84�f total dead load 2643 plf 171 plf v Total live +dead Load 3751 plf r , l�I 4943.8 plf V� Required Ftg Width 0.9 ft Selected Ftg Width 0 5 ft Selected Ftg Thickness 12 in Qu = 1978 psf Mu = 831 ft-Ibs at face of wall Vu = 1813 plf at face of wall As regd = 2 sq-in/ft phi Vn= 9498 plf at face of wall Asmin = 0.35 sq-in/ft 1.33 x As d = 0.03 sq-in/ft