Loading...
REVIEWED RESUB 1 BLD2023-0843+Interior_Lighting_Summary+8.30.2023_4.37.37_PM+37569958/30/23, 9:21 AM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW5OZXJpb3IINONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2Nv... 2U16 W NhU Compliance corms for Commercial Buildings including tiroup K2, K-i lk K4 over 3 stones and all Kl Project Title North Pacific Seafoods - 2018 WSEC Project & Applicant Project Address 130 2ND Ave S. Edmonds, WA 98020 Information Applicant Name Julia Loop Applicant Phone 206-262-9622 Applicant Email JuliaL@weaverarch.com For questions about this report, contact WSEC Commercial Technical Support at 31 REVIEWED BY CITY OF EDMONDS or via Aug 31 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT by: U2U23 NLLA, All rights reserved Date: Aug 30, 2023 BLD2023-0843 General Occupancy All Commercial General Building Use Type Office, Other Building Cond. Floor Area 19,544 General Project Types Alteration New Building or Addition Lighting Scope g g P Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 16,344 Floors Above Grade 3 Compliance Method Compliance Method 1 -General Lighting Project Description Non-structural interior Tenant improvement. New partitions, doors, finishes and lighting. Lighting Compliance Scope g g P P Project a I Type Interior / Exterior (Interior includes both interior & parking Luminaire Replacement Scope P P Compliance Method P EPA Calculation Adjustment Compliance Verification P and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Project I e North Pacific Seafoods - 2018 WSEC Date I Aug 30, 2023 Lighting Power Calculation TERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES 7 ompliance Method Building area EPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) EPA (Watts/SF) Total Watts Allowed Total Proposed Watts I Compliance Status by (SF x LPA x 1) By Building Area Building Area Office 1 16,344 1 0.64 1 10,460 L 7,162 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing -to -Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, a (Wor Luminaire pF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer (N) 2x4 Office New 170 29 4,845 Troffer (N) 2x2 Office New 3 28 84 Troffer Existing Lighting Office Existing 10 14 140 Recessed downlight (N)DL1 Office New 33 16 528 Recessed downlight (N)L1.8 Office New 3 53 159 Recessed downlight (N)L1.10 Office New 5 66 330 Recessed downlight Existing Recessed Down light Office Existing 12 60 720 Wall wash (N)WS2.19 Office New 2 16 32 Wall wash (N)L2.8 Office New 1 53 1 53 Wall -mounted (N)WS1 Office New 1 11 11 Wall -mounted (N)WS2.37 Office New 3 1 28 84 Other fixture type (N) SMl Office New 1 8 1 22 176 https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJ pb3IINONwZF9hbHRiemFOaW9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X2I ... 1 /2 8/30/23, 9:21 AM waenergycodes.com/print_project_summary_form.php?k=Y291Ym9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3ilNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2Nv... Project Title North Pacific Seafoods - 2018 WSEC Date Aug 30, 2023 Proposed Fixtures Details TERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Troffer (N) 2x4 A/A.213.I & B/A.213.1 LED Office New Fixture Description: Columbia Lighting, LCAT 22-5, 2X4 Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1 Troffer (N) 2x2 I A/A.2B.I & B/A.213.1 LED Office New Fixture Description: Columbia Lighting, LCAT 22-S, 2X2 Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer Existing Lighting A/A.2B.1 & B/A.213.1 LED Office Existing Fixture Description: Existing 1' x 4' Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight (N)DLI A/A.213.I & B/A.2B.1 LED Office New Fixture Description: Alphabet, NU Essentials, 3 inch Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1 Recessed downlight (N)L1.8 A/A.2B.1 & B/A.213.1 LED Office New Fixture Description: Vode, ZipTwo, Square 3520 Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Recessed downlight (N)L1.10 A/A.2B.I & B/A.213.1 LED Office New Fixture Description: Vode, ZipTwo, Square 3520 Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Recessed downlight Existing Recessed Down light A/A.213.I & B/A.2B.1 LED Office Existing Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall wash (N)WS2.19 A/A.213.I & B/A.213.1 LED Office New Fixture Description: WAC lighting, Styx Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall wash (N)L2.8 A/A.213.1 & B/A.213.1 LED Office New Fixture Description: Vode, ZipTwo, Square 3508 Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted (N)WS1 A/A.213.I & B/A.2B.1 LED Office New Fixture Description: WAC lighting, Styx Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted (N)WS2.37 A/A.213.I & B/A.213.1 LED Office New Fixture Description: WAC lighting, Styx Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type (N) SMl A/A.213.I & B/A.213.1 LED Office New Fixture Description: Alcon surface mount light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZl 9zY29wZV9uZXdfaW50ZXJ pb3liNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X21... 2/2