Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2023-0118+Fire_Alarm_Equipment_Specification_Sheets+12.5.2023_12.47.48_PM+3935009
North Pacific Seafood - FA Job Number: 26033 26033 North Pacific Seafood RECEIVED Dec 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2023-0118 Table of Contents Spec # Manufacturer Section Doc Name Doc # Fire AlarmSystem Windy City Wire 761360-S 1 Windy City Wire 67960 2 Gamewell FCI AMM-2F 3 Gamewell FCI AOM-2RF 4 Gamewell FCI ASD-PL3 5 Gamewell FCI ATD-1-3 6 Gamewell FCI ATD-L3R 7 Gamewell FCI B300-6 8 Gamewell FCI DNR 9 Gamewell FCI DST3 10 Gamewell FCI E3BB-FLUSH-LCD 11 Gamewell FCI GW-FAD 12 Gamewell FCI HPF-PS6B 13 Gamewell FCI LCD-SLP 14 Gamewell FCI MS-7AF 15 Yuasa NP7-12 16 System Sensor P2WK 17 System Sensor P2WL 18 System Sensor PC2WL 19 Functional Devices RIB01 BDC 20 Gamewell FCI RTS151 KEY 21 Gamewell FCI S3B-CLSS-KIT-V 22 System Sensor SCWL 23 Gamewell FCI SLC-PM 24 Spec # Section Manufacturer Doc Name Doc # Fire AlarmSystem System Sensor SWL 25 Space Age Electronics, Inc VS000645 26 Space Age Electronics, Inc VS000649 27 Fire Alarm System SNIARTWIRE CABLE SPECIFICATIONS DESCRIPTION 16 AWG 2 Conductor twisted Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) CONDUCTOR 16 (Solid Bare Copper) INSULATION Low -Smoke PVC .010" COLOR CODE Black/Red LAY LENGTH 3.5" LHL (approx. 3.4 TPF) SHIELD N/A DRAIN WIRE N/A JACKET Low -Smoke PVC .018" JACKET COLOR Red Jacket MARKING FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 16 AWG FPLP (UL) ROHS MADE IN THE USA OVERALL DIAMETER .178" Nom CABLE WEIGHT 26 Lbs/Mft. CAPACITANCE 26 pF/Ft. Nom. IMPEDANCE 72 Ohms/Mft. DC RESISTANCE 4.10 Ohms/Mft @ 20 deg. C TEMPERATURE RATING 0 C to 75 C / 300 Volt INDUSTRY STANDARDS FLAME RATING Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test AGENCY APPROVALS NEC Article 800, 760; FPLP (UL), RoHS Compliant, Made in the USA &�' All specifications referenced are nominal measurements unless otherwise noted. CABLE SPECIFICATIONS DESCRIPTION CONDUCTOR INSULATION COLOR CODE SHIELD DRAIN WIRE JACKET JACKET COLOR MARKING OVERALL DIAMETER CABLE WEIGHT CAPACITANCE IMPEDANCE DC RESISTANCE TEMPERATURE RATING INDUSTRY STANDARDS FLAME RATING AGENCY APPROVALS SMARTWIRE GL/O T E C H N O L O G Y 14 AWG 2 Conductor Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) 14 (Solid Bare Copper) Low -Smoke PVC .010" Black/Red N/A N/A Low -Smoke PVC .018" Red Jacket A L FIRE/LIFE SAFETY CONTROL CABLE INIT. / IND. DEVICE / ZONE A B C D E 0 1 2 3 4 5 6 7 8 9 14 AWG FPLP (UL) ROHS MADE IN THE USA .206" Nom 36 Lbs/Mft. 26 pF/Ft. Nom. 72 Ohms/Mft. 2.57 Ohms/Mft @ 20 deg. C 0 C to 75 C / 300 Volt M% jW Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test NEC Article 800, 760; FPLP (UL), RoHS Compliant, Made in the USA a All specifications referenced are nominal measurements unless otherwise noted. Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end -of -line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- tacts may be made addressable when connected to the AMM-2F module. The Velociti® Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-2F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Velociti® is a registered trademark of Honeywell International Inc. ULO is a registered trademark of Underwriters Laboratories Inc. VelocitiO Series AMM-2F Addressable Monitor Module ) I I f AMM Y Features • Compact size allows easy installation • Class B, Style B, initiating circuit • 40 Ohm line resistance for each initiating device circuit • Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32' to 120' F (0' to 49' C) Relative Humidity: 10 to 93% (non -condensing) End -of -Line Resistance: 47K ohms Dimensions: 1.3" L x 2.5" W x 0.5" D (3.3 x 6.4 x 1.3 cm) Ordering Information Part Number Description AMM-2F Addressable monitor module, single circuit, Style B, Class B An ISO 9001-2000 Company SIGNALING L �� 7. FM M EA l(�r (� r LISTED APPROVED Approved L S1949 3023594 227-03-E VOL IV 7300-1703:102 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. D1 page 1 of 1 Honeywell I Addressable Devices QGamewell Velociti Series"' AOM-2RF Addressable Output Relay Control Module General The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM- 2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch discrete relay contacts by code command. The relay provides two isolated sets of Form-C contacts which transfer simultaneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The module contains a panel controlled LED. The AOM-2RF is designed to mount in a 4" (10.16 cm) square junction box 21/8" (5.53 cm) deep. Ordering Information AOM-2RF: Addressable output rela control module Table 1 lists the relay contact ratings. CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3A 30 VDC Resistive Non -Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30VDC Inductive (L/R=5ms) Coded 1A 30VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non -Coded 0.7A 75VAC Inductive Non -Coded Table 1: Relay Contact Ratings FEATURES & BENEFITS • Listed under UL Standard 864 • Offers two sets of Form "C" contacts • Provides visual rotary, decimal switch addressing (01-159) • Includes a bi-color LED that flashes green wheneverthe module is addressed, and lights steady red upon activation* AOM-2RF • Designed as a compact size to allow easy installation Note 1: Only the red LED is operative in panels that do not operate in Velociti mode *Note 2:The bi-color LED functionality is not available on the GWF-7075 panel. Velociti Series' AOM-2RF Technical Specifications SYSTEMS Supervisory Current:.000375 amps. Alarm Current:.0065 amps. Operating Temperature: 32° to 1200 F (0'to 490 C) Relative Humidity:10 to 93% relative humidity (non - condensing) Dimensions: 41/2" H x 4" W x 1 1/4" (11.4 x 10.2 x 3.2 cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 49°C/32 —120°F and at a relative humidity 93%± 2% RH (noncondensing) at 32°C±21C (901F±31F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80OF. For more information Learn more about Gamewell-FCI's Velociti Series° AOM-2RF and other products available byvisiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti Series° A01V-2RF is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL:S1913 FM:3023594 MEA FDNY: 219-02-E Vol. VI CSFM: 7300-1703:0102 ISO 9001 Certification 9020-0625 1 H 108/18 ©2018 Honeywell International Inc. Fora complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-US/ documentation/Pages/ Listings.aspx Velociti® Series and Gamewell- FCI°are registered trademarks of Honeywell International Inc. UL° is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecifications are subjectto change without notice. Honeywell Honeywell I Addressable Devices SGamewell Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re -designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi - sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series° and S3 Series panels support both the Velociti° and CLIP" protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8 FEATURES & BENEFITS Photoelectric Detector • Complies with UL° • Contains a built-in • Provides rotaryaddress • Includes dual LEDs for • Offers expanded color Standard 268 7th functional test switch switches(01-159) 3601visibility options Edition activated by external •Supplies optional relay, • Designed with a new magnet isolator, or sounder profile to offer modern • Supports a low standby bases (standard or low and improved current frequency) aesthetics Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL' suffix indicates Black color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates bright white B501-WHITE: 4" Flangeless mounting base, bright white B501-WHITE-BP:4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, brightwhite B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, brightwhite B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non -relay DNRW: Intelligent duct detector housing, non -relay, watertight 2 Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detectortest magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32' F to 122' F (Do C to 50' C) Photo in Duct Applications: -41 F to 1581 F (-20° C to 70' C) Photo with Thermal: 32' F to 100' F (Do C to 38' C) Operating Humidity Range: 10%to 93% non -condensing Rate -of -Rise Detection: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (irri 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available byvisiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti° Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM:3023594 M EA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification 9020-0617 1 K 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti° and Gamewell-FCI° are registered trademarks of Honeywell International Inc. UL° is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell I Addressable Devices QGamewell Velociti° Series 3 Detectors Thermal Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be setwith rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate -of -rise thermal detection. • ATD-L3H provides fixed high -temperature detection at 190°F. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti° and CLIPI protocols, and the GWF-7075 panel supports only the Velociti" protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS Thermal Detector • Complies with UL° 268 • Contains a built-in Provides rotary address • Includes dual LEDs Offers expanded color 7th Edition functional test switch switches (01-159) used for 3601 visibility options activated b an • Designed with anew y • Supplies optional relay, profile to offer modern external magnet isolator, or sounder and improved Supports a lowstandby bases (standard or low aesthetics current frequency) Ordering Information Ordering Information NOTE: '-IV" suffix indicates Ivory color model. Accessories NOTE: "-BL' suffix indicates Black color model. NOTE: "WH" suffix indicates Bri ht White color model. ATD-1-3: Thermal heat detector, 137F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector,135°F fixed, ivory, Velociti/CLIP ATD-L3R: Thermal heat detector,135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector,135°F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector,190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector,190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. B501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangeless mounting base bulk pack, brightwhite B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B20OS-WH: Intelligent addressable sounder base, bright white B20OS-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard lowfrequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B20OS-LF-WH: Intelligent addressable low frequency sounder base, bright white B20OS-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-I R: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135" Ffixed: -41 Fto 1001 F (-20° C to 380 C) Thermal 135' F rate -of -rise: -4° F to 100' F (-20° C to 380 C) Thermal 190° F rate -of -rise: -41 F to 1351 F (-20° C to 57' C) Operating Humidity Range: 10%to 93% non - condensing Rate -of -Rise Detection:: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 570C Electrical Specifications Voltage Range::15 to 32 VDC Standby Current (@ 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.):: 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.):: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating:: 0.0063 For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti° Series 3 Thermal Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL:S2332 FM:3023594 MEA-FDNY: 219-02-E Vol. VI CSFM:7270-1703-0502 ISO 9001 Certification 9020-0620 1 G 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series°, Velociti® and Gamewell-FCI° are registered trademarks and CLIP'" is a trademark of Honeywell International Inc. UL` is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell Honeywell I Addressable Devices QGamewell Velociti° Series 3 Detectors Thermal Detectors Description The Gamewell-FCI, Velociti° Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be setwith rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate -of -rise thermal detection. • ATD-L3H provides fixed high -temperature detection at 190°F. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti° and CLIPI protocols, and the GWF-7075 panel supports only the Velociti" protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS Thermal Detector • Complies with UL° 268 • Contains a built-in Provides rotary address • Includes dual LEDs Offers expanded color 7th Edition functional test switch switches (01-159) used for 3601 visibility options activated b an • Designed with anew y • Supplies optional relay, profile to offer modern external magnet isolator, or sounder and improved Supports a lowstandby bases (standard or low aesthetics current frequency) Ordering Information NOTE: '-IV" suffix indicates Ivory color model. NOTE: "-BL' suffix indicates Black color model. NOTE: "WH" suffix indicates Bright White color model. ATD-1-3: Thermal heat detector, 135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector,1350F fixed, ivory, Velociti/CLIP ATD-L3R: Thermal heat detector,135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector,1350F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector,190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector,190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. B501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangeless mounting base bulk pack, brightwhite B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B20OS-WH: Intelligent addressable sounder base, bright white B20OS-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard lowfrequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B20OS-LF-WH: Intelligent addressable low frequency sounder base, bright white B20OS-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-I R: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti° Series 3 Detectors Technical Specifications SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135" Ffixed: -41 Fto 1001 F (-20° C to 380 C) Thermal 135' F rate -of -rise: -4° F to 100' F (-20° C to 380 C) Thermal 190° F rate -of -rise: -41 F to 1351 F (-20° C to 57' C) Operating Humidity Range: 10%to 93% non - condensing Rate -of -Rise Detection:: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 570C Electrical Specifications Voltage Range::15 to 32 VDC Standby Current (@ 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.):: 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.):: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating:: 0.0063 For more information Learn more about Gamewell-FCI's Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS The Velociti° Series 3 Thermal Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL:S2332 FM:3023594 MEA-FDNY: 219-02-E Vol. VI CSFM:7270-1703-0502 ISO 9001 Certification 9020-0620 1 G 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series°, Velociti® and Gamewell-FCI° are registered trademarks and CLIP'" is a trademark of Honeywell International Inc. UL` is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell w�NT RAF_r5 Standard, Relay, Isolator, Sounder, and Low Frequency Sounder Bases To meet local code and application requirements, Gamewell-FCI° offers standard 4" and 6" bases, as well as specialty base designs including relay, isolator, sounder and lowfrequency sounder bases that are UL listed for low frequency operation and comply with NFPA 72 �" !-_• i� requirements for sleeping spaces for the new Gamewell-FCI Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent `- systems, with screwterminals provided for power (+ and -), and remote annunciator B300-6 Standard 6" B20OS-WH Sounder connections. Communication takes place over the power (+and -) lines. The 4" base offers a Base (White) Base (White) compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ separate mounting plate that installs on various junction box sizes to eliminate unsightly surface - mount boxes. The mounting plate enables pre -wiring of all connections to speed and simplify installation. Relay bases (B224RB-WH/B224RB-IV) provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two too different modes (short and long delay). The activation time for the short delay is 60-100 B501-WHITE Flangeless B501-BL Flangeless milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin 4"Base(White) 4"Base(Black) headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224B1-IV) allow the Signaling Line Circuit (SLC) loop to operate underfauIt conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuitfrom the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/-10%with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most idealto wake sleeping occupants, even those with mild to severe hearing loss. FEATURES AND BENEFITS • Bases enable quick and secure detector • Standard white color with ivory and black Sounder bases both UL268 and UL464 plug-in options compliant • SEMS Screws provide easy wiring • Mechanical locking feature restricts connection removal of attached sensor head • UL 268 compliant • Specialty Base Features: • Support for 12-24 AWG provides • Pre -wired mounting plate simplifies installation flexibility • Multiple base formats meet application installation • Application driven feature sets Honeywell requirements QGamew�ell Zr*6-W The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/ B224RB-IV: Ivory, relay base B200S-LF-WH/B200S-LF-IV) adopt the same address as the B224BI-WH: White. isolator detector base detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder — or a group of sounders —to activate. The command set from the FACP can be tailored to multiple event - driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3,ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200SR sounder and LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal or Continuous) through ajumper. PRODUCT LINE INFORMATION INTELLIGENT BASES "-IV" suffix indicates Ivory color model. "-BL" suffix indicates Black color model. "-WH" and "-WHITE" suffix indicates White color model. B21OLP: Flanged mounted base. B21OLPA: Same as B21OLP: ULC listed. B21OLPBP: Bulk pack of B21OLP, contains 10. B224BI-IV: Ivory isolator detector base B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti° protocol B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or lowvolume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti° protocol B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200SR-WH: White, Intelligent sounder base capable of producing sound outputwith ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-IV: Ivory, Intelligent sounder base capable of producing sound outputwith ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement; intended for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/-10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applications. B300-6: White, 6" base, standard flanged low -profile mounting base MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300: White, replacement flange for B21OLP, B300-6 base B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. TR300-IV: Ivory, replacement flange for B21OLP, B300-6-IV base B501-WHITE: White, 4" standard European flangeless mounting RA10OZ: Remote LED annunciator, 3 - 32 VDC, mounts to a U.S. base. UL/ULC listed single -gang electrical box; For use with B501 and B300-6 B501-WHITE-BP: Bulk pack of 3501-WHITE, contains 10 M02-04-00: Test magnet B501-BL: Black, 4" standard European flangeless mounting base M02-09-00: Test magnet with telescoping handle B501-IV: Ivory color, 4" standard European flangeless mounting CK300: White, detector color kit, pack of 10 base B224RB-WH: White, relay base JUNCTION BOX SELECTION GUIDE CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Square 4.0" Square with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No Box depth contingent on base and wire size. Referto National Electric Code or applicable localcodesfor appropriate recommendations. Applies to all model variants "BL", "-LF", "-IV", "-WH", and "-WHITE". See Product Line Information fordetailed model description. Page 2 of 3 — 9021-60540:K • 7/8/2019 INTELLIGENT BASES TECHNICAL SPECIFICATIONS ELECTRICAL For B300-6 Series bases: • Operating voltage: 15 to 32 VDC • Standby current:170 pA maximum For B501 Series bases: • Operating voltage: 15to 32 VDC • Standby current:150 pA maximum For B200 Series bases: • External supply voltage:16 to 33 VDC (FWR) • Standby current:500 pA maximum • Alarm current for B200S(-IV)(-WH): 35 mA maximum at high -volume setting 15 mA maximum at low -volume setting • Alarm current for B200S-LF(-IV)(-WH) High - volume setting: 70 mA maximum @ 33.0 VDC 90 mA maximum C 24.0 VDC 140 mA maximum @16.0 VDC • Alarm current for B200S-LF(-IV)(-WH) Low - volume setting: 15 mA maximum C 33.0 VDC 20 mA maximum C 24.0 VDC 25 mA maximum @ 16.0 VDC • Alarm current for B200SR(-IV)(-WH): 35 mA maximum • Alarm current for 13200SR-LF(-IV)(-WH): 65 mA maximum C 33.0 VDC 90 mA maximum @ 24.0 VDC 125 mA maximum C16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) For 1322413I, B224RB (-IV) (-WH) bases: • Operating voltage: 15 to 32 VDC (powered by SLC) • Standby ratings: <450 pA maximum @ 24VDC • Set time: (13224RB(-IV)(-WH) only): short delay 60-100 msec; long delay 6-10 seconds • Reset time: (B224RB/-IV/-WH only): 20 milliseconds maximum • Relay characteristics: (B224RB/-IV/-WH only): two -coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9AC 110 VDC, and 3.0 A @ 30 VDC PHYSICAL Note: Specifications applies to all modelvariants "-BL'', "-LF", "-IV", -WH, -WHITE. See Product Line Information for detailed model description. Diameter: • B501-WHITE: 4" (10.16 cm) • 13300-6, B210LP: 6.1" (15.49 cm) • 1322413I, B224RB: 6.2" (15.748 cm) • 3200S, B200SR: 6.875' (17.46 cm) Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com Wire gauge: • 13224BI, I3224RB:14 to 24 AWG • B300-6,B210LP,B501,B200S,B200SR12to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR: 32°Fto 120°F (0°C to 49°C) • B300-6, B210LP, B501:-4°Fto 150°F(-20°C to 66°C) Humidity range: 10%to 93% RH, non - condensing System temperature and humidity ranges: This system meets NFPA requirements for oper- ation at 0°C to 49°C (320F to 12009; and at a relative humidity (non -condensing) of 85% at 30°C (86°F) per NFPA, and 93%±2%at 320C± 2°C (89.60F± 1.1°F) per ULC. However, the use- ful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended thatthis system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S911 FM Approved CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0238 9021-60540 1 K 1 07/19 ©2019 Honeywell International Inc. Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The InnovairFlexTM Series, DNR intelligent, non -relay pho- toelectric duct smoke detector, and the DNRW watertight, non -relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct. The DNR/DNRW detectors can be used with the E3 Series®and 7100 Series Systems. Note: The InnovairFlexTM Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non -condensing). An improved cover design isolates the sensor head from the low -flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Series® and Velociti® are registered trademarks and InnovairFleXT is a trademark of Honeywell International, Inc. UL® is a registered trademark of Underwriters Laboratories Inc. InnovairRefm Series DNR/DNRW Duct Smoke Housing Intelligent Non -Relay Photoelectric Duct Smoke Housinq InnovairFlex-DNR/DNRW Features • Photoelectric, integrated low -flow technology • Air velocity rating from 100 ft/min to 4,000ft/min (0.5m/s to 20.32m/sec) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non -condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 3/4-inch conduit knockout • Available space within housing to accommodate the mounting of the relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection • UL® 268A Listed • Remote testing capability • Requires SLC line power only • NEMA Type 4 UL Listed for non -hazardous indoor and outdoor applications (DNRW only) • UV Resistant, UL® Listed housing and cover material (DNRW only) SIGNALING &<S>MSFM UL� O LISTED APPROVED 2202 S911 3029700 2207 7272-1703:0121 S911 IS0®9001 GAMEWELL-FCI "t'T"ems" u"s 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60475 Rev. E page 1 of 4 i Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlexTm DNR Intelligent Non -Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —4° to 158°F (-20° to 70°C) Storage Temperature Range: —22' to 158°F (-30° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non -condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec) DCOIL - (if included) 17.5 - 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N 156-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA100Z 0 mA 12 mA Max. RTS151/RTS151 KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). 'W Figure 1 Figure 2 Figure 3 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 2 of 4 www.gamewell-fci.com Wiring for Intelligent Non -Relay Duct Smoke Detector I----1 r. — — — — I I I I I I I I I COMM. LINE {+} I 1 I I I I I I I 1 co INEM I I I 1 1 I I UL/FIVI LISTED 1ST 2N❑ CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR + RA - RA DNR TO RTS451/RTS451 KEY/RTS151/ RTS151 KEY WITH "R" REMOTE TEST CAPABLE DETECTOR HEAD OPTION: TEST COIL + TEST COIL - COMM + OUT (CONY ONLY) + COMM - RAIRTS - orad RA10OZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS451KEY RTS151/RTS151KEY JUMPER ..J TEST COIL + TEST COIL - COMM + OUT (CONY ONLY) + COMM - RAIRTS - RA + RTS + Figure 6 DNR to RTS1 51/RTS1 51 Key (-) P016ER (+) SUPPLY 1 2 9 RT151/RTS151 KEY REMOTE TEST STATION LED OPTION 1 PER UNIT TEST COIL OPTION 1 PER UNIT 95mA CURRENT DRAW Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001 R and the Duct Application Smoke Detectors Application Guide. • The RTS1 51/RTS1 51 KEY test coil circuit requires an external 24 VDC power supply which must be LIL Listed. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. � I � Figure 7 RTS151 UL S2522 Figure 8 RTS151KEY UL S2522 Figure 9 RA10OZ UL S2522 Figure 10 ASD-PL2FR Ordering Information Part Number Description DNR Intelligent non -relay photoelectric low -flow duct smoke detector DNRW Watertight intelligent non -relay photoelectric low -flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151/RTS151151 KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1ft (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 4 of 4 www.gamewell-fci.com Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The InnovairFlexTM Series, DNR intelligent, non -relay pho- toelectric duct smoke detector, and the DNRW watertight, non -relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct. The DNR/DNRW detectors can be used with the E3 Series®and 7100 Series Systems. Note: The InnovairFlexTM Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non -condensing). An improved cover design isolates the sensor head from the low -flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Series® and Velociti® are registered trademarks and InnovairFleXT is a trademark of Honeywell International, Inc. UL® is a registered trademark of Underwriters Laboratories Inc. InnovairRefm Series DNR/DNRW Duct Smoke Housing Intelligent Non -Relay Photoelectric Duct Smoke Housinq InnovairFlex-DNR/DNRW Features • Photoelectric, integrated low -flow technology • Air velocity rating from 100 ft/min to 4,000ft/min (0.5m/s to 20.32m/sec) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non -condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 3/4-inch conduit knockout • Available space within housing to accommodate the mounting of the relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection • UL® 268A Listed • Remote testing capability • Requires SLC line power only • NEMA Type 4 UL Listed for non -hazardous indoor and outdoor applications (DNRW only) • UV Resistant, UL® Listed housing and cover material (DNRW only) SIGNALING &<S>MSFM UL� O LISTED APPROVED 2202 S911 3029700 2207 7272-1703:0121 S911 IS0®9001 GAMEWELL-FCI "t'T"ems" u"s 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60475 Rev. E page 1 of 4 i Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlexTm DNR Intelligent Non -Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL Listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —4° to 158°F (-20° to 70°C) Storage Temperature Range: —22' to 158°F (-30° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non -condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec) DCOIL - (if included) 17.5 - 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N 156-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA100Z 0 mA 12 mA Max. RTS151/RTS151 KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). 'W Figure 1 Figure 2 Figure 3 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 2 of 4 www.gamewell-fci.com Wiring for Intelligent Non -Relay Duct Smoke Detector I----1 r. — — — — I I I I I I I I I COMM. LINE {+} I 1 I I I I I I I 1 co INEM I I I 1 1 I I UL/FIVI LISTED 1ST 2N❑ CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR + RA - RA DNR TO RTS451/RTS451 KEY/RTS151/ RTS151 KEY WITH "R" REMOTE TEST CAPABLE DETECTOR HEAD OPTION: TEST COIL + TEST COIL - COMM + OUT (CONY ONLY) + COMM - RAIRTS - orad RA10OZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS451KEY RTS151/RTS151KEY JUMPER ..J TEST COIL + TEST COIL - COMM + OUT (CONY ONLY) + COMM - RAIRTS - RA + RTS + Figure 6 DNR to RTS1 51/RTS1 51 Key (-) P016ER (+) SUPPLY 1 2 9 RT151/RTS151 KEY REMOTE TEST STATION LED OPTION 1 PER UNIT TEST COIL OPTION 1 PER UNIT 95mA CURRENT DRAW Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001 R and the Duct Application Smoke Detectors Application Guide. • The RTS1 51/RTS1 51 KEY test coil circuit requires an external 24 VDC power supply which must be LIL Listed. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. � I � Figure 7 RTS151 UL S2522 Figure 8 RTS151KEY UL S2522 Figure 9 RA10OZ UL S2522 Figure 10 ASD-PL2FR Ordering Information Part Number Description DNR Intelligent non -relay photoelectric low -flow duct smoke detector DNRW Watertight intelligent non -relay photoelectric low -flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151/RTS151151 KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) IDST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1ft (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 4 of 4 www.gamewell-fci.com Honeywell QGamewell �P� Analog and Networking Systems E3 Series"' Cabinets Cabinets used for the E3 Series General The E3 Series' Expandable Emergency Evacuation System by Gamewell-FCI offers several cabinet size options. The E3 Series System is a modular design that allows a wide range of configurations to form an integrated, distributed fire alarm system. These cabinet options allow for sturdy and modern installations. The E3 Series cabinet assembly is a compact, wall -mounted enclosure. A typical cabinet includes a backbox and an outer locking door. In addition, there are several inner door options and mounting plates to accommodate a variety of E3 Series sub -assemblies. Each cabinet backbox includes mounting patterns for plates to allow the installer to arrange and secure the sub -assemblies to the backbox. The backbox knockouts are also positioned at numerous points to allow a conduit access into the enclosure. The following four Annunciator cabinet sizes provide the maximum flexibility that can meet any application. • Cabinet AA offers 2-slot or 3-slot options to accommodate any of the following configurations: — Inner door, 2-slots allows space for one LCD-E3 or _CD-SLP and one ASM-16 — Inner door, 3-slots allows space for any combination of three modules: ASM-16, NGA or an ANU-48 • Cabinet Al houses one NGA or one ASM-16/ANU-48. • CabinetA2 accommodates a single LCD-E3. • E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. The E3BB-R-BSIim or B-Slim contains the 600 Series cabinet. Cabinet B includes a mounting plate that contains a space for the following modules: • ILI-MB-E3/ILI95-MB-E3 • PM-9/PM-9G sub -assemblies • Batteries set inside the backbox Additional sub -assembly options mounted on the backbox include the DACT-E3 and RPT-E3. The 2-slot inner door houses the following options: • one _CD-E3 module and- either one ASM-16/ANU-48 or one NGA module FEATURES & BENEFITS • IBC Seismic Certified • 16-gauge steel backbox • Contains removable outer and inner doors • Lexan°windows appear on the doors of most cabinets, except the Cabinet "C" and "D" INX cabinets and the INX CAB-B cabinet which contain louvered doors • Built with an inner door bonding strap used to provide electrical continuity for grounding • Cabinets are available in either black or red E3 Series' Cabinets • Backbox and door ground studs provide positive grounding, and 1800 opening door with full clearance • Offers 901 opening door with zero clearance • Includes a keylock with quarter turn latch • Trim Ring accessories available General Both the C and D-size Command Center cabinets house a variety of E3 Series Broadband sub- assemblies that can be used in multiple configurations that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and D-size Command Center cabinets that may contain any of the following: • fire fighter's phone handset • microphone • optional modules to meet the facility operation requirements Refer to the Inner Door and Backbox Mounting Capacities in the Ordering Information Section. Ordering Information Inner Door Mounting Capacity Part Number Description Cabinet "AA" Size Dimensions: 191/4" W x 10" H x 41/2" D (49 W x 25 H x 11.4 D cm) E3BB-BAA Enclosure, Black, "AA" (LOC) Size E3BB-RAA Enclosure, Red, "AA" (LOC) Size E31D2-TA Inner Door, 2-slots (INCC-TEL&ASM-16) E31D2-A Inner Door, 2-slots (LCD-E3 or _CD-SLP &ASM-16) E31D3-A Inner Door, 3-slots (NGA, ASM-16 and MIC) Cabinet "AAl" Size: Dimensions: 8 3/4" W x 10" H x 41/2" D (2 2 W x 2 5 H x 11.4 D cm) E3BB-BAAl Remote Enclosu re, Black, w/I nner Door, 1 slot, (NGA) E3BB-RAA1 Remote Enclosure, Red, w/Inner Door, 1-slot, (NGA) Cabinet "A2" Size: Dimensions: 131/4" W x 10" H x 41/2" D (40 W x 25 H x 11.4 D cm) E3BB-BA2 Remote Enclosure, Black,w/Inner Door, 1-slot, (LCD-E3 or _CD-SLP) E3BB-RA2 Remote Enclosure, Red, w/Inner Door, 1-slot, (LCD-E3 or _CD-SLP) Flush Cabinet A2 Annunciators: Dimensions: 131/4" W x 10" H x 41/2" D E3BB-FLUSH-LCD CAB A2 Remote Flush LCD ANN with Key E3BB-NGA-FLUSH CAB A2 Remote Flush NGA ANN with Password protected Cabinet "B-Slim" Size: (Retrofit Kits) Dimensions: 14" W x 20" H x 41/2: D (35.5 Wx 50.8 H x 11 D cm) E3BB-RBSLIM Assy, Enclosure, B-SLIM, Red with Backplate and _CD-E3 Keyswitch plate IF600-RETROFIT Door and Cab mounting plates, disable key switch and door lock (PK-625) for E3 Series upgrade. Cabinet "B" Size: Dimensions: 19 3/8"W x 19 3/8"H x 41/2"D (49 W x 49 H x 11 D cm) E3BB-BB Assy, Backbox Enclosure, Black,"B" Size E3BB-RIB Assy, Backbox Enclosure, Red, "B" Size E31D2-B Inner Door, 2-slots, "B" Size 1100-0458 B Size INCC Command Center enclosure, black 1100-0459 B Size INCC Command Center enclosure, red door 1100-0460 1 NX-Transponder 19" (cm) Backboxwith Door, Black Ordering Information (Continued) Part Number Description Cabinet "B" Size (Continued) Dimensions: 19 3/8"W x 19 3/8"Hx41/2"D (49 W x 49 H x 11.43 D cm) Cabinet "C" Size: Dimensions: 19 3/8" W x 30" H x 41/2" D (49 W x 76 H x 11 D cm) E3BB-BC/INCC Enclosure, Command Ctr, Black, "C" Size E3BB-RC/INCC Enclosure, Command Ctr, Red, "C" Size E31D2-C Assy, Inner Door, Command Ctr.2-Bay"C"Size E31D3-C Assy, Inner Door, Command Ctr, 3-Bay"C"Size E3BB-BC/INX Assy, Transponder, Black, "C" Size E3BB-RC/INX Assy, Transponder, Red, "C"Size E3-INCC-CPLATE Command Center module mounting plate,"C" Size E3-INX-CPLATE Transponder mounting plate, "C" Size Inner Door Mounting Capacity E3-ILI-CPLATE Intelligent loop module mounting plate "C" Size Cabinet "D" Size: Dimensions: 19 3/8" W x 41" H x 41/2" D (49 W x 104 H x 11 D cm) E3BB-BD/INCC Enclosure, Command Ctr, Black, "D" Size E3BB-RD/INCC Enclosure, Command Center, Red, "D" Size E31D2-D Assy, Inner Door, 2-Bay, "D" Size E31D3-D Assy, Inner Door, 3-Bay, "D" Size E3BB-BD/INX Enclosure, Transponder, Black "D"Size E3BB-RD/INX Enclosure, Transponder, Red, "D"Size E3-INCC-D-PLATE Command Center module mounting plate, "D" Size E3-INX-D-PLATE Transponder module mounting plate, "D" Size Optional Extender Plates AM-50 Plate AM-50 Extender Plate FPT-GATE-3-EXT FPT-GATE-3 Extender Plate Optional Accessories 1100-0450 Command Center, blank plate, single size E3-BP Inner door panel, blank, double size 90375 PM-9/PM-9G Adapter Plate Kit,Hardware E3-TRIMKIT-A Trim kit for"A"/"AA"size enclosure, black E3-TRIMKIT-Al Trim kit for Ul" size enclosure, black E3-TRIMKIT-A2 Trim kit for "A2"size enclosure, black E3-TRIMKIT-B Trim kit for "B"size enclosure, black E3-TRIMKIT-C Trim kit for "C"size enclosure, black E3-TRIMKIT-D Trim kit for "D" size enclosure, black Bulk Amplification AA-100 100 WAudioAmp.@70.7 VRMsw/120 VAC AA-120 120 W Audio Amp. C 25 VRMS w/ 120 VAC ACT-1 Audio coupling transformer, for audio systems w/multiple supplies FCI-CHG-120 Battery Charger, 25-120 A/H Gel cell FCI-LBB Battery box, accommodates batteries up to 55 A/H, (Black) Cabinet C: FCI-DR-C4B Large Battery Backbox,blank door,lock and keys for backbox accepting 3 chassis, (Black) FCI-DR-C4BR Blank door, lock and keys, for backbox accepting 3 chassis, (Red) SBB-C4 Backbox, 3 chassis, (Black) Cabinet D: FCI-DR-D4B Blank door, lock and keys, for backbox accepting 4 chassis, (Black) FCI-DR-D4BR Blank door, lock and keys, for backbox accepting 4 chassis, (Red) SBB-D4 Backbox, 4 chassis, (Black) 90516 7100-Slim 7A/H Seismic Battery Bracket Kit Seismic Battery Bracket Kits Part Number Description E3 B-Slim 7 A/H Seismic Battery Bracket Kit 90517 7100-Slim 12 A/H Seismic Battery Bracket Kit E3 B-Slim 12 A/H Seismic Battery Bracket Kit 90518 E3 CAB-B 7 A/H Seismic Battery Bracket Kit Ordering Information (Continued) Seismic Battery Bracket Kits (Continued) Part Number Description E3 CAB-C 7 A/H Seismic Battery Bracket Kit E3 CAB-D 7 A/H Seismic Battery Bracket Kit NetSOLONS-INX-7A/H Seismic Battery Bracket Kit NetSOLO-7100-7A/H Seismic Battery Brckt Kit 90519 E3 CAB-C (INX only)12 A/H Seismic Battery Bracket Kit E3 CAB-D (INX only)12 A/H Seismic Battery Bracket Kit NetSOLO NS-INX 12 A/H Seismic Battery Bracket Kit 90520 E3 CAB-B 18 A/H Seismic Battery Bracket Kit E3 CAB-C 18 A/H Seismic Battery Bracket Kit E3 CAB-D 18 A/H Seismic Battery Bracket Kit Retrofit Kits For information on the Gamewelland 7200 Retrofit Kits, referto the following Data Sheets. 9021-60678 Gamewell Retrofit Kits Data Sheet 9021-60733 7200 Retrofit Kits Data Sheet Inner Door Mounting Capacity Part Number Components Cabinet AA E31D2-A Cabinet AA, Inner Door, 2-slots 1 -CD-E3 Display and 1 ASM-16/ANU-48 E31D2-TA Assembly, Door, Inner,TEL-E3 E31D3-A, Cabinet A, Inner Door, 3-slots 1 NGAorASM-16 2 ASM-16s/ANU-48 CabinetAAl E31D-Al Cabinet AAl,InnerDoor (Includes Box) 1 NGAorASM-16 CabinetA2 E31D-A2 CabinetA2, Inner Door, (Includes Box) 1 -CD-E3 Cabinet B E31D2-B Cabinet B, Inner Door, (Includes Box) 1 -CD-E3 Display and one ASM-16/ANU-48 1 NGA and one ASM-16/ANU-48 B-Slim Cabinet 1 -CD-E3 Display & one RPT-E3 or one DACT-E3 1 ILI-MB-E3 or one ILI95-MB-E3 1 PM-9 or one PM-9G Cabinet C E3ID2-C Cabinet C,Inner Door, 2-slots 1 -CD-E3 Display and 5 Any combination of ASM-16/ANU-48,NGA or Microphone Assemblies 1 Telephone Assembly E3ID3-C Cabinet C,Inner Door, 3-slots 7 Any Combination of ASM-16/ANU-48, NGA, or Microphone Assemblies 1 Telephone Assembly Cabinet D E3ID2-D Cabinet D, Inner Door, 2-slots 1 LCD-E3 Display 11 Any Combination of ASM-16/ANU-48, or NGA or Microphone and 1 Telephone Assembly E3ID3-D Cabinet D, Inner Door, 3-slots 13 Any Combination of ASM-16/ANU-48,NGA or Microphone Assemblies 1 Telephone Assembly 1 Loop Interface or ANX or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Backbox Mounting Capacity E3BB-BAA Enclosure `AA' (LOC) Size Black 1 INI-VG Series Voice Gateway E3BB-BAA1 AA1 Size Box/Door, Black 1 RPT-E3 Network Repeater E3BB-BB B-Size Box/Door, Black 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3/ILI95-MB-E3 and Backbox Mounting Capacity (Continued) Part Number Components E3BB-BB B-Size Box/Door, Black 1 Additional ILI-MB-E3/ILI95-MB-E3 1 Loop Interface orANXor 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater INX CAB-B Mounting Plate 1 PM-9 or PM-9G 1 I N I-VGX 4 AM-50Series amplifiers E3-INCC-C Plate 1 PM-9/PM-9GPower Supply 1 I N I -VG Series Voice Gateway 1 ILI-MB-E3/ILI95-MB-E3 Loop Interface and Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 OptionalAM-50 or FPT-GATE-3 Extender Plate E3-ILI-C Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 2 Additional ILI-MB-E3/ILI95-MB-E3or ILI-S-E3/ILI95-S-E3 orANX 1 DACT-E3 1 RPT-E3 1 Optional FPT-GATE-3 Extender Plate E3-INX-C Plate 1 PM-9/PM-9G Power Supplywith one PM-9/PM-9G Adapter Plate 1 I N I-VGX Voice Gateway 1 ILI-MB-E3 Loop Interface and 1 Additional ILI-MB-E3/LI95-MB-E3/ANX 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 4 AM-50Series Amplifier 1 Optional FPT-GATE-3 Extender Plate E3-INCC-D Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 4 Additional ILI-E3 or ILI95-E3 Series orANX 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 I N I -VG Series 1 OptionalAM-50 or FPT-GATE-3 Extender Plate E3-INX-D Plate 1 PM-9/PM-9GPower Supply 1 ILI-MB-E3 or ILI95-MB-E3 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 I N I -VG Series 4 AM-50 SeriesAmplifier 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center (Voice), Black 1 PM-9/PM-9GPower Supply 1 I N I -VG Series Voice Gateway 4 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface 1 Additional ILI-MB-E3/ILI95-MB-E3/ ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center, Black 1 PM-9/PM-9GPower Supply 7 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface & Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Optional Extender Plates AM-50 Extender Plate 1 AM-50-25 orAM-50-70 FPT-GATE-3 Extender Plate 1 FocalPoint° Gateway PNET-1 Optional FPT-GATE-3 Extender Plate E3 Series" Cabinets Technical Specifications STANDARDS The E3 Series fire alarm control panel cabinets are designed to comply with the following standards: UL Standards: UL 864 9th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non -coded and Master Coded Operation Underwriters Laboratories Standard UL 2572 (Mass Notification Systems). UUKL for Smoke Control UL25721st Edition NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16 - Standard for Foam -Water Sprinkler and Foam Water Spray Systems NFPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry ChemicaV17A Wet Chemical Seismic Codes International Building Codes: IBC 2013 IBC 2009 IBC 2006 IBC 2003 I BC 2000 (Seismic) California Building Code CBC 2007 (Seismic) For more information Learn more about Gamewell-FCI's E3 Series® Cabinets and other products available byvisiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The E3 Series Cabinets are designed to comply with the certifications, please visit: following standard: http://www.gamewell- UL Standard: UL 864 9th Edition fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules E3 Series°, FocalPoint® and specified in this document. In some cases, certain Gamewell-FCI° are registered modules or applications may not be listed by certain trademarks of Honeywell approval agencies, or listing may be in process. Consult International Inc. factory for latest listing status. Lexan° is a registered UL Listed: S1869 trademark of GE Plastics, a MEA Approved: 6177 subsidiary of General Electric Fire Dept. of New York: COA# 6077 Company. CSFM: 7165-1703-0125 UL° is a registered trademark FM Approved: 3025415 of Underwriter's Laboratories City of Chicago Inc. City of Denver This document is not intended VMA Seismic Certified to be used for installation ISO 9001 Certification purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. w 06/18 @2018 Hon Honeywell ©2018 Honeywell International Inc. Honeywell I Accessories SGamewell Fire Alarm Documents (FAD) Cabinet Fire Alarm Storage Cabinet General The Gamewell-FCI Fire Alarm Documents Cabinet (FAD) is the perfect solution to meet the demanding code standards required today. Gamewell-FCI's primary goal is to manufacture code compliant solutions and this product allows you to dojustthat. This cabinet is the answer to comply with the NFPA 72 2007, Section 6.2.2.1 requirements which states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit. The Fire Alarm Documents cabinet may be used as a storage box for both printed and digital documentation, enabling you to storethe system'stest and certified inspection documents, service records, manuals and AS built drawings. This cabinet is constructed of durable 16 gauge steelwith a solid piano hinge and key lock. The cabinet includes a 4GB USB memoryflash drive interface. Using a standard USB B connector, the USB flash drive interface allows you to use any standard USB printer cable to upload or download information. This feature allows you to store the fire alarm software in one secure place, so that the Technician can easily access the software and service the system. Fire Alarm Documents Cabinet The Fire Document Box (FDB) interior is designed to contain critical manuals and documents. It is constructed with a durable steel retainer. The FDB has two key ring hooks to hold system keys, and a frame to insert Authorized personnel business cards. In the inner door, you can add the Legend Sheet to record property, system, service, code and AHJ certification information, as well as required documentation. (See Figure 2). Ordering Information: GW-FAD: Fire Alarm Storage Cabinet, Red FEATURES & BENEFITS • Installed with a 4 gigabyte digital flash drive interface with USB B connector • Overall Dimensions 12"Width x 13" Height x 21/4" Depth (30.48 W x 33.02 H x 5.71 D cm) • Offers two, key ring hooks to hold the system keys • Contains a frame plate to insert Authorized Personnel business cards • Constructed with 16 gauge steel box and cover for added security with a solid stainless steel hinge • Coated with a durable, baked -on finish (other colors available) • Builtwith a stainless steel piano hinge with standard 3/4"cat 30 key lock (other lock assemblies available) • Includes a Legend Sheet to record passwords and system information • Imprinted with white indelible ink, 1" high Lettering labeled, "FIRE ALARM DOCUMENTS" Figure 1 shows the interior enclosure of the Fire Alarm Documents cabinet. Interface requires B-B Connector Hooks Card Holder Legend sheet used to store system information including the following: Contacts Sign -off Maintenance Test information -Alternate locations of additional records Figure 1 Fire Alarm Documents Cabinet Figure 2 shows the Legend Sheet attached to the inner door of the Fire Alarm Document Cabinet (See Figure 2). Property Information Minimum Required Documentation Name of Property: 1 Written narrative providing intent and system description. Address: FIN/A FEnclosed or Alt. Location: 2 Riser diagram Description of Property: Occupancy Type: FIN/A F Enclosed or Alt. Location: Certification and Approvals 3 Floor plan layout showing location of all devices and control equipment. 16.1 System Installation Contractor: F�N/A Enclosed or Alt. Location: This system, as specified herein, has been installed and 4 Sequence of operation in either an input/ output matrix or narrative form. tested according to all NFPA Standards cited therein. FIN/A F Enclosed or Alt. Location: Signed: 5 Equipment technical data sheets. FIN/A FEnclosed or Alt. Location: Printed Name: Date: I / 6 Manufacturers published instructions, including operation and maintenance instruction. Organization: FIN/A FEnclosed or Alt. Location: Title: 7 Battery calculations (where batteries are provided). FIN/A FEnclosed or Alt. Location: 8 Voltage drop calculations for notification appliance circuits. Phone: 16.5 Authority Having Jurisdiction: I havewitnessed a satisfactory acceptance test of thiswith FIN/A FEnclosed orAlt. Location: system and find it to be installed and operating properly in 9 Completed record of inspection and testing in accordance with 7.6.6 and 7.8.2. accordance with its approved plans and specifications, FIN/A FEnclosed or Alt. Location: its approved sequence of operations, and with all NFPA 10 Completed record of completion in accordance with 7.5.6 and 7.8.2. standards cited herein. FIN/A FEnclosed or Alt. Location: Signed: 11 Copy of site specific software, where applicable. FIN/A FEnclosed or Alt. Location: Printed Name: Date: I / 12 Record (as -built) drawings. Organization: FIN/A FEnclosed or Alt. Location: Title: 13 Periodic inspection, testing, and maintenance documentation in accordance with Section 7.6. FIN/A FEnclosed or Alt. Location: Phone: Equipment Information: ID No. 1: 14 Records, record retention, and record maintenance in accordance with 7.7. FIN/A FlEnclosed or Alt. Location: Serial: Access Code: ID No. 2: Signed: Date: Serial: Access Code: Figure 2 Legend Sheet Fire Alarm Documents (FAD) Cabinet Technical Specifications SYSTEMS FAD: Fire Alarm Documents Cabinet Dimensions: 12"W x 13" H x 21/4" D (30.48 W x 33.02 H x 5.71 D cm) Door Keylock: Barrel lock and piano hinge Dimensions: 3/4" barrel lock and 12" (30.48 cm) piano hinge FAD Cabinet: UL° Listed, constructed of 18 gauge cold rolled steel Cabinet Finish: Red powder coat epoxy finish Cabinet Cover Label: Silkscreen imprinted with white indelible ink,1" high lettering labeled, "FIRE ALARM DOCUMENTS" Cabinet Keylock: Keylocked with 3/4" barrel lock and 12" (30.48 cm) width stainless steel piano hinge Cabinet Backbox: The backbox includes a 4-hole knockout mounting pattern. Cabinet Frame Plate: insert frame plate accommodates and protects standard 81/2 x 11 manuals and document records. Cabinet Inner Door Label: Legend Sheet attached to the inner doorframe for system required documentation, key contacts and code information. Cabinet Flash Drive Interface:4 Gigabyte (minimum) digital flash memory drive with a standard USB B connector (used to upload and download information) is securely assembled to the interior cabinet. The drive is restricted to Authorized personnel with permission to use secure hardware devices to access the records. Cabinet Key Holder: Two key ring holders and a pre - assembled frame plate to insert Authorized Personnel business cards. For more information Learn more about Gamewell-FCI's Fire Alarm Documents (FAD) Cabinet and other products available by visiting www.Gamewell- FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The Fire Alarm Documents (FAD) Cabinet is designed to certifications, please visit: comply with the following standard: http://www.gamewell- UL Standard: S2580 fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules Gamewell-FCI® is a registered specified in this document. In some cases, certain trademark of Honeywell modules or applications may not be listed by certain International Inc. approval agencies, or listing may be in process. Consult factory for latest listing status. Space Age Electronics, Inc. is a ©copyright. UL: S2580, Vol. 3 CSFM: 7300-0553-0110 UL° is a registered trademark NFPA: 72 2007 of Underwriter's Laboratories Inc. NEMA ISO 9001 Certification This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. 1oO5/18 @2Honeywell ©2018 Honeywell ywee ll International Inc. SERIES 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Gamewell-FCI and is a direct replacement forthe GFPS6/9.The HPF-PS6 is a 6 amp and the HPF-PS10 is a 10 amp, remote power supplywith battery chargerthat may be connected to any 12 or 24 voltfire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and otherfire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently -configurable, power - limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) • Configurable for ANSI' Temporal 3or Temporal coded output • UL-Listed NAC synchronization using System Sensor', Wheelock', Gentex°, or AMSECO° appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) orthree (10 amp model) fully -isolated input/control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end -of -line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire HPF-PS6/10 HPF-PS6110B • Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit • HPF-PS6/10 includethe- Honeywell Power Products lock set (PN:17059) and key (PN: 17051) Honeywell QGamewell jZr*=f ORDERING INFORMATION HPF-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS613: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black HPF-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS1013: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black ZNAC-PS: Optional Class A converter card, sold separately AOM-2SF: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. AOM-2RF: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch AMM-41F: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A AMM-21F: Dual Monitor Module. Same as AMM-4F except it provides two inputs for Class B wiring only AMM-21RIF: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only MMO-6SF: Six -circuit supervised control module MMO-61RF: Six Form-C relay control module EOLR-1: 12/24VDC end -of -line relay for monitoring four -wire smoke detector power BAT-1270-BP: Battery,12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery,12 volt, 18AH, 2-pack BAT-12330: Battery,12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. 17070: Alternate Honeywell Gamewell-FCI lock set, PK-625, 3/8" cam Page 2 of 3 — 9021-61096:C • 3/10/2021 PS SERIES TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER HPF-PS6(B): 120VAC, 50/60 Hz, 5.OA maximum HPF-PS10(B):120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • HPF-PS6B: TB8-TB9 —1A Regulated, 3A special applications; TB10-TB12 — 0.3A Regulated, 3A special applications • HPF-PS1013: TB8-TB11— 1.5A Regulated, 3A special applications; TB12-TB14 — 0.3A Regulated, 3A special applications • 6.0 A (HPF-PS613) or 10.0 (HPF-PS10B) maximum total continuous current for all outputs Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.gamewell-fci.com SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The H PF-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S24562 CSFM: 7315-1637:0505 FDNY Approved FM Approved 9021-61096 1 C 1 03/21 ©2021 Honeywell Internationallnc. Honeywell QGamewell LI LCD Touchscreen Annunciator Display The LCD-SLP is a touchscreen interface used Iwith the S3 Series and E3 Series"' panels. GENERAL The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series and E3 Series° Systems. The LCD-SLP provides an easy -to -use, intuitive interface for the operator's control. The 4.3" (10.92 cm) color touchscreen display shows the following: • System Status • Event Details Service Modes The following identify the LED Indicators that display on the panel. • AC (green) • Fire Alarm (red) • Hazard (blue) • Supervisory (yellow) • Trouble (yellow) • Silenced (yellow) The five fully -programmable front panel switch/LED combinations provide a direct access to perform the following tasks: • Device Bypass • Lamp Test Enable/Disable Groups or Devices The display features the following physical switches: • Menu • System Reset Drift Walk Test • Five Programmable Switches INSTALLATION The LCD-SLP panel's adaptable design allows itto be mounted in a variety of S3 Series, E31 Series or Retrofit cabinet installations. For additional information, refer to the E3 Series Cabinets Data Sheet, P/N:9020-0649. • S3 Series Cabinets: — SLP-BB basic system enclosure — S3BB-BB/S3BB-RB system enclosure • E3 Series' Cabinets: — AA size cabinet (E3BB-BAA, E3BB-RAA) — A2 size cabinet (E3BB-BA2, E3BB-RA2) — A size flush cabinet (E3BB-FLUSH-LCD) — B-Slim cabinet (E3BB-RBSLIM) — B size cabinet (E3BB-BB, E3BB-RB) — C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) — D size cabinet (E3BB-BD/INCC, E3BB-RD/INCC) • Retrofit Cabinets: — 600-RETROFIT — 7200-B-RETROFIT — 7200-C-RETROFIT ORDERING INFORMATION LCD-SLP: LCD Touchscreen display unit E3BB-BA2: Remote enclosure with inner door, black, one LCD slot E3BB-RA2: Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD: Remote flush mounting enclosure, black, LCD slot FEATURES AND BENEFITS • Listed per ANSI/UL° Standard 864,10th Edition • UL Listed and FM approved for Pre- Action/Deluge and Agent Releasing • Provides 4.3" (10.92 cm) colortouch- screen display of System Events • Includes five custom function buttons with LEDs for direct access to system controls. • Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases • Both the E3 Series 0LI-MB-E3/I1_I95- M B-E3) and the S3 Series (SLP) support up to 15 LCD-SLP displays via the RS- 485 serial interface • Offers the following installation options: — Locally mounted in the E3 Series and S3 Series panels: — Remotely mounted in the E3 Series, A2 cabinet — LCD Flush enclosure XENON e o LCD-SLP • Displays the following six LED indica- to rs: — AC Power —Alarm — Hazard — NAC Silence — Supervisory — Trouble Honeywell LCD-SLP TECHNICAL SPECIFICATIONS SYSTEMS Operating Voltage: 24 VDC FWR Operating Current: 0.030 amp Alarm Current: 0.065 amp Operating Temperature: 321to1200 F (0' to 49' C) Relative Humidity: 0 to 93%,non-condensing at 900 F (32' C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 490C/32 — 120OF and at a relative humidity 93% ± 2% RH (non - condensing) at 320C±20C (90°F± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 270C/60 — 80°F. STANDARDS Honeywell Gameweil-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com The LCD-SLP is designed to comply with the following standard: UL Standard: UL 864, loth Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 UL 864, loth Edition FM Approved MEA FDNY: COA # 6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification 9021-60782 1 G 1 06/20 ©2020 Honeywell International Inc. Honeywell �Giarrwml ® Honeywell I Addressable Devices QGamewell MS-7 Series Manual Fire Alarm Pull Stations General The Gamewell-FCI, MS-7 Series man ualfire alarm pullstations are available in a wide variety of configurations. The pullstations comply with the Americans with Disabilities Act(ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pullstations include a key lock/resetwhich is keyed alike with the Gam ewe ll-FCI fire alarm control panels and other man ualfire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog MS-7 Series addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi - flush mounting • Shock and vibration resistant • Conventional stations Both single and double suitable for use with action pull stations any UL Listed control available panel • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-1/0 backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi -flush mounted on a standard double -gang, or4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. 2 NYC -Plate The NYC -Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC -Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action statio MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual -action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-1/0 - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi -flush mount, plastic NY -PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all Material: Lexan� lihlli The MS-7 Series is designed to com wth the following g p y g compliance approvals and certifications, please visit: Contact Ratings: 0.25 amps. C 30 VAC/VDC (resistive) standard: http://www.gamewell- Dimensions: 5 5/8" H x 41/4" W x 1 1/4" D UL Standard: UL 864 9th Edition fci.com/en-US/ (14 x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx Operating Temperature: These listings and approvals apply to the modules LEXANI is a registered (MS-7AF, MS-7ASR 320 to 1200 F (00 to 490 C) specified in this document. In some cases, certain trademark of GE Plastics, a (MS-71-013): -30° to 150' F (-350 to 66' C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies, or listing may be in process. Company. (MS-7AF, MS-7ASF):10 to 93% (non -condensing) Consult factory for latest listing status. Velociti° and Gamewell-FCI (MS-71-0131): 85%± 5% @ 860 ± 3.60 (300 ± 20 C) UL: S2465 are registered trademarks of Alarm Current:.0030 amp. 0.007 for LED FM: 3023594 Honeywell International Inc. Supervisor Current: Y MEA FDNY: 67-02-E Vol. VII . UL`is a registered trademark (MS-7AF, MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. 7160-1703:0170 This system meets NFPA requirements for operation at 0 This document is not intended - 490C/32 -120OF and at a relative humidity 93%± 2% 7160-1703:0109 to be used for installation PH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). ISO 9001 Certification purposes. We tryto keep our However, the useful life of the system's standby batteries product information up -to - and the electronic components may be adversely affected date and accurate. We cannot by extreme temperature ranges and humidity. Therefore, cover all specific applications or anticipate all requirements. it is recommended that this system and its peripherals be All specifications aresubjectto installed in an environment with a normal room change without notice. temperature of 15 - 270C/60 - 80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 Honeywell ©2017 Honeywell International Inc. NP SERIES - NP7-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES • Superb recovery from deep discharge. • Electrolyte suspension system. • Gas Recombination. • Multipurpose: Float or Cyclic use. • Usable in any orientation • Superior energy density. • Lead calcium grids for extended life. • Manufactured World wide. • Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals W7.12 ; =* �r Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. Layout 4 Q 0 Faston tab-- 187 A Faston tab, 256 ❑ ras - oas o INCH = MM .aw - .W4 D20 INCH = T" .256 6.35 --1 �— .31 6 7.96 059 .185 4.70 .250 6.35 --- .124 3.15 .16 4.0 .00S 2.56 a 631 6.8 .05965s 1.5a 031 0.80 .004 0.1 0 as, - ooa os, General Specifications Nominal Capacity (Ah) NP7-12 20hr to 1 .75vpc 300C 7 1 Ohr to 1 .75vpc 20°C 6.4 5hr to 1.70vpc 200C 5.9 1 hr to 1 .60vpc 20°C 4.2 Voltage 12 Energy Density (wh.L.20hr) 91 Specific Energy (Wh.kg.20hr) 32 Int. Resistance (m.Ohms) 25 Maximum discharge (A) 40/75 Short Circuit current (A) 210 Dimensions (mm) Length 151 Width 65 Height overall 97.5 Weight (Kg) 2.65 Terminal A/D Layout 4 Terminal Torque Nm - NP SERIES - NP7-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications Separators The use of the special separator material provides a very efficient insulation between plates preventing inter -plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME Blle Chnlga ♦a gl"'my OnuOe � 0.] 150 17 T •t .I� ii�-�ffi �I 0.25 46 I 16 I C"]k- 0.4 iq. 10Q 15 Ch.W ]6 Lumlrt Tl9 PoIIrtOA6 C e 10 NP DISCHARGE CHARACTERISTICS CURVES AT 252C (772F) M PI) Note_ C -Given c pa 14V as stated on each Ea .l In Ah FOR 12V FOR 6V BATTERY BATTERY NP AT 25'G (]]°F) 13.0 s.5 12.06.0 c� tt.0 5.5 O _ - a 10.0 5.0 - a 2CA � 6Cn p 9.0 4. 8.0 4.0 3C 1 2 4 6 1 20 49 fi0 2 4 fi 610 20 MINUTES HOURS DISCHAFG E TIME FLOAT SERVICE LIFE NP RANGE TESTIN5CONDITIONFLOATINGVOLTACE2.275VFC H (AH%) AM BIENT TE M PERATURE_ 20-G (9VF TO 72T) C) 120 a U 100 O SO 1310 Uj z Jm 40 U 20 ¢q W 0 S¢ 1 2 3 4 5.5 LIFE (YEARS) Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15°C to 50°C Discharge — 20oC to 60oC Storage — 20oC to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS 9'0),60 75 -1C -C (s0°F) U c� 50 20°C 8°F) 40°C (10C 'G (86T) 25 6 9 2 15 18 STORAGE TIME (MONTHS) FLOAT CHARGE CHARACTERISTICS w il'2 %i g� 8w 0.25CA- 2.275VPC CONSTANT VOLTAGE WAR3INCL 720 0-2G 1.RO ����C `y,pRp�P VOLUMIE_ - _ _ — 15.0 100 R20 _ - -- - 7pp OHAROE VOLTAGE 14.0 a1s e 4 AFTER 1C0%WSCHARCE 1S0 0.10 SOV 016CRARRE ie 6.06 12.0 � UA6 5.50 'NA-," CVRRENT 11A 12 14 16 is 20 CHABOING TWr 1UGU-S) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CON DFION3: DISCHARGE CURRENT. 0.17C Amp. (F.V 1.7WCELL CHARGING CURRENT C.09C Amp. w CHARGING VOLVME� 125°% OF DISCHARG ED CARACITV AM BIEN TTEMPERATU RE.20°C TO 25°C 1BWF TO]7°F) 5 , a � 1 a U C 100% 50°F� 30�ie DEFT DOD BOB OF DISCH HOE xao aoo loon NUMBER OF CYCLES Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Y U A S A Registered number 1548820 Cat No I NP7-12 Janua 08 oi�� SYSTEM � SENSOR' Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Aaencv Listinas SIGNALING O LISTED F M S4011 (chimes, horn strobes, horns) APPROVED MEA a pp roved ,O. 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 53593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189 (horns, chimes) ,= System S;7ensojr SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 oF. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40oF to 151OF (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data 1�1�PiF.j'7!'fit77�•iii-Tt�li�l"�l^/ Candela _. T 8-17.5 Volts DC FWR 16-33 Volts DC FWR I L rijax. Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 185 NA NA NA NA 281 286 251 258 UL Max. Current Draw (mA RMS), 2-Wire Horn 8-17.5 Volts Strobe, Standard Candela 16-33 Volts Range (15-115 cd) DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, High 177 Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with ,8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output (cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 1 177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams Wall -Mount Horn Strobes Wall Plastic Weatherproof Back Box I if t R Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, Hi h cd, Red, Outdoor includes plastic weatherproof back box P2WK-t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK't 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK`t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK"t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK`t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK"t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: ' Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4 SYSTEM ©2012 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change withou men notice. Visit systessoccom _4 SOVSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current information, including version of this data sheet. AVDS01201 • 3/12 oi�� SYSTEM � SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts r F I R E • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING S F M APPROVED 0 LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2018 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVDS865-05 • 2/22/2018 • Page 3 L-Series Dimensions 1.91' 3.46" 48.5 mm 88 mm 1.25' 3.46" 88 mm 1.25' 3.57" 1.55" 32 mm (9.1 cm) (3.9 cm) 32.. �O O a ° 0oo0°o°0o6° 090o000° LIPo c°°c° 5.38' 5.27„ d 4L_�_�_°'4 133.9 mm 5.27" �°0°p0Q°1°D°0 °°n°°°°°°°a°° (13.7 cm) O 133.9 mm °o°n°o°o°n°o° A�0°°�°VOA°0° oao�n nao�nro�e�o � Oao�000ao o O G� A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70' (11.94 cm) (4.85 cm) 1.25" (3.18 mm) (14.4 cm) L " Strobe, Horn Strobe A0550-00 L-Series Ordering Information Horn 1.25" 4.82" 32 mm (1224 cm) 1.9 (4.69 cm) 4 UP O ® O 5O 14.6 8 cm) A0549-00 A0554-01 Wall Surface Mount Back Box SBBRUSBBWL Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. "Horn -only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St. SYSTEM Charles, IL 60174 ©2018SystemSensor . Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensoccom for current product information, including the latest version of this data sheet. temsensor.com SENSORa www.systemsensor.com y AVDS865-05. 2/22/2018 oi�� SYSTEM � SENSOR' Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12101/2017 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (rnA DC Input RMS), Ceiling 8-17.5 Volts 15cd Horn Strobe, 30cd Candela 16-33 Volts 15cd Range (15-177 30cd cd) 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern 8-17.5 16-33 Volts Volts dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non-Temooral Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 6.83" d (173 n 2.47" (62.7 mm) 1.37" (34.8 mm) Ceiling -Mount Horn Strobes A0545-00 -01 6.92- Ili- (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information 2.5" (64 mm) O A0546-00 M Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. SENSOR' Product specifications subjectto change without notice. Visit systemsensoccom for current product information, including the latest version of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS868-02 • 12/01/2017 RIB® Functional !, `I Devices, Inc: (800) 888-5538 RIB01 BDOmp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input Org N/O Rik 120 Vac Yel Wht CONTROL C Neutral CIRCUIT Blu N/C Dry Contact Input Wht/Red Wht/Blu SPECIFICATIONS # Relays & Contact Type: One (1) SPOT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30-x 3.20-x 1.80-with .50-NPT Nipple Wires: 16-, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, ROHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No sales(afunctionaldevices.com ® www.functionaidevices.com C UL US ° C E ° UL us LISTED pa�.t;xxn�=�xx=.�axa xanxixxmwinEs AeHSNe,tnVx BIXIX=1rtNx lOAe�Y4s�N41 1)]Vs SSarA@Ix1M1 C E ton�w�yunxO,tNVae iery at xxurcoxru w x s ¢:nvat mM=vniar nwvxwaaxr.lmvaa xro=aaage n waxwrovn.nrvx xrc=mue RoN3 Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770VA Pilot Duty @ 120Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 AmpTungsten @ 120 Vac (N/O) 240 WattTungsten @ 120 Vac (N/Q 2 HP @ 277 Vac 1HP@ 120Vac Power Input: 42mA @ 120Vac Notes: • Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. 20191121 Functional Functional Devices, Inc. Toll -free: (800) 888-5538 Email: sales@functionaldevices.com RIB 101 Commerce Drive Office: (765) 883-5538 Website: www.functionaldevices.com Devices, InC. Sharpsville, IN 46068 Fax: (765) 883-7505 TERMS AND CONDITIONS OF SALE 1. OFFER, GOVERNING PROVISIONS AND CANCELLATIONS: This document constitutes an offer or counter-offer by Functional Devices, Inc. or any of its affiliates ("Seller") to sell various products as agreed by Seller ("Products") to the buyer named on the reverse side ofthis document or in other applicable print or electronic documentation ("Buyer') in accordance with these terms and conditions. This writing is not an acceptance of any offer made by Buyer. This offer or counter-offer is expressly conditioned upon Buyer's assent to these terms and conditions and no others. Buyer is deemed to have assented to these terms and conditions (including Seller's warranty) when the first ofthe following occurs: A. Buyer signs and delivers to Seller an acknowledgement copy of any of Seller's quotation, order acknowledgement or invoice forms; B. Buyer gives to Seller (orally or in writing) specifications of quantity and/ or type, assortments thereof, delivery dates, shipping instructions, instructions to bill, or the like as to all or any part ofthe Products; C. Buyer receives delivery of any of the Products; or, D. Buyer has otherwise assented to the terms and conditions hereof. Where an attachment to this Agreement or separate document referencing this Agreement consists of a quotation, the quotation remains open for acceptance for a period ofthirty (30) days or such other period as specified in the quotation. Seller hereby rejects any additional or different terms or provisions contained in any purchase order, acknowledgment or other communication heretofore or hereafter received from Buyer. Seller's delivery of Products does not constitute an assent to any terms proposed by Buyer. Except for an officer of Sel ler, no representative of Seller has any authority to waive, alter, vary, amend, or add to the terms hereof. THESE TERMS AND CONDITIONS OF SALE CONSTITUTE THE ENTIRE AGREEMENT rAGREEMENT") BETWEEN SELLER AND BUYER WITH RESPECT TO THE MATTERS ADDRESSED HEREIN. 2. PRICES: The prices for the Products are based on the terms and conditions herein, including the limitations of liability and warranties, and all such terms and conditions are material to the sale ofthe Products. In the event Seller fails to provide a price quote and/or terms prior to the acceptance ofthe order, Buyer will pay Seller's then -current list price for such Products. All quotations and invoices show the net selling price of each item quoted. In the event of a mathematical error, the quoted price per Product governs. 3. TERMS OF PAYMENT: Buyer will pay the fees specified in each invoice provided by Seller in United States Dollars within thirty (30) calendar days after the invoice date unless otherwise agreed to in writing by an authorized representative of Seller. Any amount due under this Agreement that remains unpaid after its due date will bear interest from the date that such payment became delinquent until the date it is paid in full at the lower of 1.5% per month, which equals an annual percentage rate of 18%, or the maximum rate permitted bylaw. Seller reserves the right to establish, revoke or modify credit terms for Buyer at anytime. No discounts are allowed unless otherwise agreed to in writing by an authorized representative of Seller. Buyer will pay any collection fees, legal fees, or court costs incurred by Seller to collect past due amounts. No offsets or setoffs of payments due to Seller hereunder are allowed with respect to any other agreement between the parties. Seller hereby retains alien on the goods sold for unpaid purchase money as herein provided. 4. TAXES AND OTHER CHARGES: In addition to the prices quoted or invoiced, Buyer will pay any sales tax, excise tax, use tax, value added or consumption tax, customs duty (that is assessed on the delivery of Product(s) to a destination outside ofthe U.S.A.), fee or charge of any nature whatsoever imposed by any governmental authority on or measured by the transaction between Seller and Buyer. In the event Seller is required to pay any amount, Buyer will reimburse Seller therefore; or provide Seller, at the time the order is submitted, an exemption certificate or other document acceptable to the authority imposing the same. Seller does not accept and will not pay any fines, penalties or chargebacks from Buyer for any reason. 5. DELIVERY, RISK OF LOSS, CLAIMS AND FORCE MAJEURE: A. All prices quoted for products are Ex -Works (Incoterms 2010) at a shipping facility determined by Seller, unless otherwise noted by Seller ("Seller's Shipping Facility"). Risk of loss or damage, and beneficial ownership, ofthe Products are transferred to Buyer when the Products are made available to Buyer at Seller's Shipping Facility. All delivery dates are approximate. B. Buyer will only make written claims to Seller for damages, shortages or other delivery errors within seven (7) calendar days after receipt of shipment. All Products received by Buyer, or Buyer's clients, customers, or agents, that are not rejected within such time will be deemed accepted. Failure to provide such written notice constitutes a waiver of all such claims regarding such shipment by Buyer. Buyer will not revoke acceptance. C. Seller is not liable for any damage as a result of any delay or failure to deliver due to any act of God, act of Buyer, embargo or other governmental act, regulation or request, fire, accident, power outage, strike, civil unrest, weather, slowdown or other labor difficulties, war, riot, act ofterrorism, delay in transportation, defaults of common carriers, inability to obtain necessary labor, materials or manufacturing facilities or, without limiting the foregoing, any other delays beyond Seller's control. Buyer's sole and exclusive remedy for any delays orfor Seller's inability to deliver Products for any reason, in each case, that persists for more than ninety (90) days, is to cancel the order pursuant to Seller's Order Policies and Guidelines available upon request. 6. WARRANTY; DISCLAIMER. Products are warranted to be free from manufacturing defects under normal use and conditions for five (5) years (the "Warranty Period"). The warranty does not apply to: (a) Damage caused by accident, abuse, mishandling, or dropping; (b) Products which have been subjected to unauthorized repair, opened, or taken apart; (c) Products not used in accordance with direc- tions; (d) Damages exceeding the cost of such Product; and (e) Damages caused by lightning, water, or condensation. If warranty service is required during the Warranty Period, and if examination shall disclose to Seller's satisfaction that such Product was originally defective, then Seller will at its option repair or replace the product without charge upon prepaid delivery of such Product to Seller's facility with proof of date of purchase. Corrections of such defects by repair to or supplying of replacements for defective parts shall constitute fulfillment of all obligations of Seller. Seller shall not be liable for loss, damage, or expense directly or indirectly caused from the failure of Products to perform as expected. EXCEPT AS SET FORTH HEREIN, SELLER DISCLAIMS ALL REPRESENTATIONS OR WARRANTIES OF ANY KIND WHATSOEVER, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, NON -INFRINGEMENT, FITNESS FOR A PARTICULAR PURPOSE OR ANY WAR- RANTY ARISING FROM A COURSE OF DEALING OR USAGE OFTRADE. NO PERSON (INCLUDING ANY AGENT, DEALER OR REPRESENTATIVE OF SELLER) IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTY CONCERNING PRODUCTS EXCEPTTO REFER BUYERTOTHIS AGREEMENT. BUYERWARRANTS THAT BUYER HAS NOT RELIED ON ANY OTHER WARRANTIES OR REPRESENTATIONS CONCERNING THE PRODUCTS ORTHIS AGREEMENT. For warranty service, call factory for RA number and send such Product prepared with sales receipt to: FUNCTIONAL DEVICES, INC.,101 COMMERCE DRIVE, SHARPSVILLE, IN 46068. 7. LIMITATION OF LIABILITY: SELLER WILL NOT BE LIABLE FOR ANY LOSS OF PROFIT, INTERRUPTION OF BUSINESS OR ANY OTHER SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES SUFFERED OR SUSTAINED BY BUYER FOR ANY REASON. EXCEPT FOR CLAIMS OF DEATH OR PERSONAL INJURY, IN NO EVENT WILL SELLER'S AGGREGATE LIABILITY TO BUYER ARISING UNDER OR IN ANYWAY RELATED TO THIS AGREEMENT FOR ANY REASON (INCLUDING, BUT NOT LIMITED TO, LIABILITY ARISING FROM NEG- LIGENCE OR ON THE BASIS OF STRICT LIABILITY, OR OTHERWISE) EXCEED THE TOTAL AMOUNT PAID BY BUYER TO SELLER HEREUNDER FOR ANY PRODUCT GIVING RISE TO A CLAIM UNDER THIS AGREEMENT. 8. RETURNS: Unless otherwise approved by Seller in writing in its sole discretion, except in the case ofa non -conforming shipment or a warranty issue, Buyer may not return Products. If Seller approves the return of Products pursuant to the preceding sentence, such returned Products must be returned within ninety (90) days from date of invoice and will be subject to a 25% restocking fee. In the event of a non -conforming shipment or a warranty issue, Buyer may return Products, but only if Buyer first: (a) provides notice to Seller as required in this Agreement, (b) obtains prior authorization from Seller, and (c) all Products or containers for which return is properly authorized have been marked with a return authorization number supplied by Seller. Buyer will make all returns via a traceable form such as Federal Express, UPS or insured mail and in resalable condition. Buyer will pay all return shipping charges and any other charges associated therewith. 9. CANCELLATIONS: Cancellation or deferment of all or part of an order is subject to acceptance by the Seller. If accepted, any reduction in quantity of any item to less than 85% ofthe original item quantity is subject to a 15% cancellation charge. If an order cancellation is accepted, the Buyer will make delivery and pay for all material manufactured and in stock or in process at time of notice for such order, and for any special materials on orders for which the Seller must take delivery. 10. EXPORTS. Buyer agrees that it will comply with any and all U.S. Export Controls and will not pay for, resell, transfer or knowingly sell Products in violation of U.S. Export Controls. If Buyer resells Products within or exports Products to a country or region which imposes upon Seller and/or Buyer an obligation to fund or undertake reuse, recycling, composting, recovery of Products, or any similar obligation (e.g., the European Union's Waste Electrical and Electronic Equipment Directive, EC 2002/96/EC) (the "Obligations"), Buyer shall wholly under- take the Obligations or duties and shall be entirely responsible for all associated costs therewith. Seller shall have no obligation to reimburse Buyer for execution ofthe Obligations. In the event that Seller is named in a proceeding based upon the Obligations, Buyer shall indemnify, defend and hold Seller harmless from all actions related thereto, including all civil and governmental actions. 11. MISCELLANEOUS. This Agreement is governed by the laws of the State of Indiana, without giving effect to its conflict of laws principles. Buyer hereby irrevocably consents and submits to the exclusive jurisdiction and venue of the state and federal courts in Marion County, Indiana. The United Nations Convention for Contracts for the International Sale of Goods is explicitly excluded. Each provision contained in this Agreement constitutes a separate and distinct provision severable from all other provisions. If any provision (or any part thereof) is unenforceable under or prohibited by any present or future law, then such provision (or part thereof) will be amended, and is hereby amended, so as to be in compliance with such law, while preserving to the maximum extent possible the intent of the original provision. Any provision (or part thereof) that cannot be so amended will be severed from this Agreement; and, all the remaining provisions ofthis Agreement will remain unim- paired. No modification, addition or deletion, or waiver of any rights under this Agreement is binding on a party unless made in a non -preprinted agreement clearly understood by the parties to be a modification or waiver, and signed by a duly authorized representative of each party. F2700 2.1.2020 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The InnovairFlex Series Duct Smoke Detector accessories add functionality to the duct detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All Gamewell-FCI duct detectors and accessories are UL Listed. The following duct smoke detector accessories are avail able • APA151 Piezo Annunciator • MHR Mini -Horn, Red • MHW Mini -Horn, White • RA100Z/RA100ZA Remote Annunciator • RTS151KEY Remote Test Station with Key • u I- igna ing Accessory • AOS Add -On Strobe • RTS2-AOS Multi -Signaling Accessory The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with Gamewell-FCI 4-wire conventional duct smoke detec- tor applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert® Advance mini -horns fea- ture temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single - gang back boxes for applications where a small device is desired. The RA10OZ and RA10OZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condi- tion. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi- colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. InnovairFlexTMand Sync-CircuitTA1 are trademarks and SpectraAlert0 is a registered trade- mark of Honeywell International Inc. InnovairRefm Series Duct SMoke Detector Accessories Notification and Test Accessories SMOKE -- I • ,ter - I InnovairFlex-Series Accessories Features • APA151 piezo annunciator offers a new style and pro- vides enhanced audible alarm signals • MRH and MHW SpectrAlert Advance mini -horns feature temporal and continuous tones for both high and low volume settings • RA100Z and RA100ZA remote annunciators flexible versatility are used for both conventional and intelligent applications • RTS151 and RTS151 KEY remote test stations are designed to test duct detectors from remote locations • RTS2 and RTS2-AOS multi -signaling accessories are used with the InnovairFlex 4-wire conventional duct smoke detectors An ISO 9000-2000 Company SIGNALING UL FM LISTED pro GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2009 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60532 Rev. A page 1 of 3 Description (Continued) The RTS2 and RTS2-AOS multi -signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add -On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator Voltage: Regulated 24 VDC Operating Voltage: 16 to 33 VDC Maximum Alarm Current: 30 mA Temperature Range: 0°C to 49°C (32°F to 120°F) Relative Humidity: 10 to 93% non -condensing Wire Gauge: 12 to 18 AWG Dimensions: 4.6" H x 2.9" W x .45" D (11.6Hx7.3Wx1.1 Dcm) MHR/MHW SpectrAlert@ Advance Mini -Horns Voltage: Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage: 8 to 33 VDC (9 to 33 VDC with Sync -Circuit"' Module) Sounder Current Draw: 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range: 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non -condensing Nominal Sounder Frequency: 3 kHz Wire Gauge: 12 to 18 AWG Dimensions 4.6" H x 2.9" W x 0.45" D (11.6Hx7.3Wx1.1 Dcm) RA100Z/RA100ZA Remote Annunciator Voltage Range: Conventional System: 3.1 to 32 VDC Intelligent System: 18to32VDC Maximum Alarm Current: 12 mA Dimensions: 4.6" H x 2.8" W x 1.3" D (11.6 H x 7.1 W x 3.3 D cm) Specifications, Duct Smoke Detector Accessories (Continued) RTS151 Remote Test Station Power Requirements: Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 seconds max. Temperature Range: -10°C to 60°C (14°F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 18 AWG Dimensions: 4.8" H x 2.90" W x 1.4" D (12.1 H x 7.3 W x 3.5 D cm) RTS151 KEY Remote Test Station with Key Power Requirements: Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time: 40 seconds max. Temperature Range: -10°C to 60°C (14°F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 18 AWG Dimensions 4.6" H x 2.75" W x 1.8" D (11.6 H x 6.9 W x 4.5 D cm) RTS2 and RTS2-AOS Multi -signaling Accessory Voltage: 20 to 29 VDC Power Requirements: Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder: 85 dBA at ten feet Temperature Range: -10°C to 60°C (14°F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 22 AWG Dimensions: 4.8" W x 5.3" H x 1.6" D (12.1 WX13.4HX4.0Dcm) For the very latest product specifications and listing infor- mation, please visit the Gamewell-FCI Web site at www.gamewell-fci.com. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60532 Rev. A page 2 of 3 www.gamewell-fci.com Accessories Gamewell-FCI provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL Listed. �r 4 • Figure 1 RTS151 UL S2522 Figure 5 RA100Z UL S2522 Ordering Information Part Number Description a i Figure 2 RTS151KEY UL S2522 Figure 6 MHW UL S4011 Accessories Part Number Description APA151 Piezo Annunciator MHR Mini Horn, Red MHW Mini Horn, White RA100Z/RA100ZA Remote annunciator alarm LED RTS151 Remote test station Figure 3 APA151 UL S4011 Figure 7 MHR UL S4011 SMOKE I t - t , Figure 4 RTS2-AOS UL S2522 Figure 8 RTS2-AOS with PS24LOW Strobe and PS12/24 LENSW lens Part Number Description RTS151 KEY Remote test station with key lock RTS2 Multi -signaling accessory AOS Add -On Strobe RTS2-AOS Multi -signaling accessory GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60532 Rev. A page 3 of 3 FIRE ALARM CONTROL PANELS S313-CLSS-KIT-V SLP-BLK + CLSS Gateway + Verizon Module S3 Series CLSS Gateway Bundle S3 Series CLSS Gateway Bundle enables us to read the connected device system inventory from one panel or a network of panels and transmitting this data to the Connected Life Safety Services (CLSS) Cloud. S3 Series CLSS Gateway Bundle enables us to read the connected device system inventory from one panel or a network of panels and transmitting this data to the Connected Life Safety Services (CLSS) Cloud. The gateway board can be connected with the CLSS Cloud, a configuration computer, a panel, a mobile device, and an external power supply. The CLSS Gateway is a key component for optimizing CLSS functionality. The CLSS Gateway can also be used as a Fire Alarm Communicator to central station when used with the optional cellular module and feature activation. Features & Benefits: S3 Series CLSS Bundle provides a connected offering of a Addressable Fire Alarm Control Panel and CLSS Gateway that enables: • Updates of a connected device system inventory from one or a network of panels • The CLSS gateway connects with the CLSS Cloud to be configured by computer, a panel, a mobile device, and even an external power supply. • The CLSS Gateway is also a Fire Alarm Communicator to central station when used with the optional cellular module and feature activation • Transmits data to the Connected Life Safety Services (CLSS) Cloud L SKU: S3B-CLSS-KIT-V Description: SLP-BLK + CLSS Gateway + Verizon Module oi�� SYSTEM � SENSOR' Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12101/2017 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (rnA DC Input RMS), Ceiling 8-17.5 Volts 15cd Horn Strobe, 30cd Candela 16-33 Volts 15cd Range (15-177 30cd cd) 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern 8-17.5 16-33 Volts Volts dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non-Temooral Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 6.83" d (173 n 2.47" (62.7 mm) 1.37" (34.8 mm) A0545-00 Ceiling -Mount Horn Strobes -01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information 6.92- Ili— (175. Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 2.5" (64 mm) O A0546-00 M Model Description �•• Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2017 System Sensor. SENSOR' Product specifications subjectto change without notice. Visit systemsensoccom for current product information, including the latest version of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS868-02 • 12/01/2017 Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI, S3 Series (Small Addressable Fire Alarm Control Panel) uses the following plug-in Signaling Line Circuits (SLC). • SLC-PM (Signaling Line Circuit Personality Module) • SLC95-PM (Signaling Line Circuit-95-Personality Module) Each SLC-PM/SLC95-PM provides one SLC loop in Class B or Class A wiring. The SLC-PM supports the following devices: • Up to 318 System Sensor Velociti® devices. - 159 sensors and 159 modules. • Up to 198 System Sensor CLIP devices. - 99 sensors and 99 modules. The SLC95-PM supports the following devices: • Up to 126 Apollo XP95 devices. - 126 sensors and modules. Installation The SLC-PM/SLC95-PM modules are designed to be plugged into the Smart Loop Panel -Main Board (SLP-E3). This feature allows you to expand the S3 Series System without the need to remove or replace hardware. Specifications SLC-PM SLC95-PM Operating Current: 0.014 amp 0.016 amp Alarm Current: 0.014 amp 0.016 amp Line Impedance: 40 Ohms Line Capacitance: 0.5 pf max. Operating Voltage: 24 VDC FWR Operating Temperature: 32' to 120' F (0' to 49' C) Relative Humidity: 0 to 93%,non-condensing at 90' F (32' C) Ordering Information Part Number Description SLC-PM System Sensor, Signaling Line Circuit - Personality Module with up to 318 devices. SLC95-PM Apollo SLC Personality Module with up to 126 devices. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. SLC-PM/ SLC95-PM SLC Personality Loop Modules SLC-PM (System Sensor) SLC95-PM (Apollo) Features Listed per ANSI/UL® Standard 864 9th Edition • SLC-PM supports the System Sensor Velociti protocol using up to 318 devices. - Uses up to 159 sensors and 159 modules. • SLC95-PM supports the Apollo XP95 protocol using up to 126 devices. - Uses up to 126 sensors and modules. Supports Class A or Class B Wiring. Offers a simple, plug-in installation feature SIGNALING City of M EA Chicago C LISTED FDNY: Approved S1869 COA-#6162 7165-1703:0176 Class 1 Reference Certificate of Compliance VMA-45894-02C IS0910101 GAMEWELL-FCI "'r" °"•""° 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. \2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60781 Rev. C page 1 of 1 oi�� SYSTEM � SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts r F I R E • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING S F M APPROVED 0 LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2018 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7-W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVDS865-05 • 2/22/2018 • Page 3 L-Series Dimensions 1.91' 3.46" 48.5 mm 88 mm 1.25' 3.46" 88 mm 1.25' 3.57" 1.55" 32 mm (9.1 cm) (3.9 cm) 32.. �O O a ° 0oo0°o°0o6° 090o000° LIPo c°°c° 5.38' 5.27„ d 4L_�_�_°'4 133.9 mm 5.27" �°0°p0Q°1°D°0 °°n°°°°°°°a°° (13.7 cm) O 133.9 mm °o°n°o°o°n°o° A�0°°�°VOA°0° oao�n nao�nro�e�o � Oao�000ao o O G� A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70' (11.94 cm) (4.85 cm) 1.25" (3.18 mm) (14.4 cm) L " Strobe, Horn Strobe A0550-00 L-Series Ordering Information Horn 1.25" 4.82" 32 mm (1224 cm) 1.9 (4.69 cm) 4 UP O ® O 5O 14.6 8 cm) A0549-00 A0554-01 Wall Surface Mount Back Box SBBRUSBBWL Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SIP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. "Horn -only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St. SYSTEM Charles, IL 60174 ©2018SystemSensor . Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensoccom for current product information, including the latest version of this data sheet. temsensor.com SENSORa www.systemsensor.com y AVDS865-05. 2/22/2018 AC1 Cabinet Thumb Latch m m ° o ° 0 Door Open Door Closed 0 0 0 8.61 6.38 10 8.37 0 0 Ground Lug o 4.25 6.49-� '0 6.25 MOUNT TO BACKPLATE WITH STANDOFF MAT.) I AC1 SPECIFICATIONS /IN: CABINET SIZE/PN: TC1 DATE: 1 1 /1 /18 HINGE: L COVER SCREENING: VS000645 Unless otherwise specified UNIT COLOR: RED INSTALLATION: INDOOR DRY Dimensions are in Inches PROJECTION: WIRING DETAILS: -( Q+ — ALL WIRES 16AWG TOLERANCES: ANGLES: f0.5° UNLESS OTHERWISE NOTED LINEAR: .X f.062 .XXX f.015 .XX t.031 XXXX f.005 CUSTOMER: DFC019 SCALE: 1 :1 SAE/OWNER: SAE# PART NO: N/A DRAFTER: go MANUFACTURING: ENGINEERING: TI TLE: .eSPACE AGE ELECTRONICS, INC. AC1 RED AOM2RF MR801 PVC SIZE: FILE LOCATION: SHEET: D AVS 1 /1 CODE: N ET00331 DWG: REV: VS000645 1 ►NFIDENTIAL INFORMATION: The information contained in this document is the property of Space Age Electronics, Inc. e holder of this document shall keep all information contained herin confidential and shall protect same in whole or in part from disclosure and dissemination to all third parties. SLC INITIATING CIRCUIT POS. FROM FIRE ALARM CONTROL PANEL OR NEG. CLOSEST EXISTING INITIATING DEVICE SLC INITIATING CIRCUIT POS. TO NEXT DEVICE OR RETURN TO ORIGINATING NEG. DEVICE TO MAINTAIN CIRCUIT SUPERVISION TO ELEVATOR CONTROLLER "PRIMARY FLOOR" CONNECTION BY OTHERS TO ELEVATOR CONTROLLER "ALTERN) CONNECTION TO ELEVATOR PK-625 KEY LOCK 13.500 AC2 CABINET DETAILS LIFT -A -WAY COVER 8.5 x 11 DOC. SLEEVE UL LISTED ENCLOSURE � mb 2.375 4.375 1.407 _460 13,740 3.422 1,519 CAT-30 KEY LOCK 13.740 6 6,750 L --Jj .5� 3.423 1.407 5) QUAD EKO FOR 1/2' 3/4', 1-1/4', 1-1/2' CONDUIT 2.375 4,375 L3,500 11.562 MOUNTING HOLES O O 11.875 MOUNTING 13.500 HOLES O O 0 0.250