Loading...
REVIEWED BLD2024-0442+Manufacturer_Specifications_and_Installation_Instructions+4.2.2024_10.23.28_AM+4170751RECEIVED BLD2024-0442 Apr 082024 Job Name: System Reference: Date: mnBMSHI ELECTRIC b., "I 1 FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection REVIEWED BY CITY OF EDMONDS Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 43,000 // 43,000 // 43,000 Rated Capacity BTU/H 40,500 // 39,000 // 37,500 Minimum Capacity BTU/H W W % 12,600 // 12,600 // 12,600 4,775 // 4,775 H 4,775 4,403 // 4,286 // 4,112 98.9, 98.9 H 98.9, 98.9 H 98.9, 98.9 Maximum Power Input Rated Power Input Power Factor (208V, 230V) Heating at 47°F2 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 53,600 // 53,600 // 53,600 Rated Capacity BTU/H 45,000 // 43,000 H 41,000 Minimum Capacity BTU/H 11,400 // 11,400 // 11,400 Maximum Power Input W 6,160 // 6,160 // 6,160 Rated Power Input W 3,575 // 3,519 H 3,463 Power Factor (208V, 230V) % 98.1, 98.1 // 98.2, 98.2 // 98.2, 98.2 Heating at 17°F3 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 30,500 // 29,800 H 29,100 Rated Capacity BTU/H 24,400 // 23,700 H 23,000 Maximum Power Input W 4,750 H 4,991 // 5,231 Rated Power Input W 2,943 // 2,906 H 2,869 Heating at 5°F4 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 25,000 H 25,000 H 25,000 Maximum Power Input W 5,000 H 5,200 // 5,400 Efficiency (Non -Ducted // Mix // Ducted) SEER 19.7 H 17.4 H 15.2 EER' 9.2//9.1H9.0 HSPF (IV) 10.3 H 9.7 H 9.1 COP at 47°F2 3.69 // 3.58 // 3.47 COP at 17°F at Maximum Capacity3 1.88 H 1.75 // 1.63 COP at 5°F at Maximum Capacity' 1.47 // 1.42 // 1.36 ENERGY STAR® Certified No H No H No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 40 Recommended Wire Size AWG 14 Minimum Circuit Ampacity A 32.5 Maximum Overcurrent Protection A 40 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,150 / 2,550 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling' dB(A) 56 Sound Pressure Level, Heating' dB(A) 58 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model MNB33FBTMC-L Compressor Rated Load Amps A 20 Compressor Locked Rotor Amps A 28.8 Compressor Oil Type // Charge oz. FV50S H 37.2 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 41-17/64 [1,048] Package Dimensions W: In. [mm] 41-3/8 [1,050] D: In. [mm] 17-3/8 [440] H: In. [mm] 46-3/4 [1,190] Unit Weight Lbs.[kg] 189 [86] Package Weight Lbs.[kg] 214 [97] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.415 Refrigerant Charge Lbs, oz 8.0, 13.0 Chargeless Piping Length Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 'A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-5C42NA3 Maximum Number of Connected IDU Indoor unit connection Minimum Number of Connected IDU Minimum connected capacity Maximum connected capacity BTU/H BTU/H 5 2 12,000 51,000 Liquid Pipe Size O.D. (Flared) Gas Pipe Size O.D. (Flared) Total Piping Length Piping Maximum Height Difference, ODU above IDU Maximum Height Difference, ODU below IDU Farthest Piping Length from ODU to IDU Maximum Number of Bends for IDU In.[mm] A,B,C,D,E: 1/4 [A,B,C,D,E: 6.35] In.[mm] A: 112; B,C,D,E: 3/8 [A: 12.72: B,C,D,E: 9.52] Ft. [m] 262 [80] Ft. [m] 49 [15] Ft. [m] 49 [15] Ft. [m] 82 [25] 80 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Refrigeration Ball Valve - 1/2" ❑ PAC-SH96SG-E ❑ BV12FFS12 Refrigeration Ball Valve - 1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Drain Socket Drain Socket ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-Al M-NET Converter M-NET Converter ❑ PAC-IF01 MNT-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater ❑ PAC-645BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adapter Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801 M 24" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Side Air Intake* MOT 1.FREE SPACE E v E 3-15/16" or nore IF 2.SERVICE SPACE E 6 FORM# MXZ-5C42NA3 - 202206 SPACE 7/8 23-5/8" Rear Air ntake Air Discharge v E °o 7777T Unit: inch (mm) 2-U Shaped Notched Hole (Foundation Bolt N10) 1.1 3/32 \ 2-(15/32"X1-13/32") Oval Hole (Foundation Bolt M10) Lo GAOSJUnit E GAS,Unit D LIO 1/4"(96.35)FLARE LID i GA53/8"(®9.52)FLARE GAS Unit C GASLIO �Unit B LIO Unit A—LIO 1/4"(06.35)FLARE GAS GAS1/2"(012.7 )FLARE Conduit plate Top nnector conauit plate under 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvae.com cONus Intertek Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.