FOR REF REV2 BLD2023-1312+Plumbing_Plan+1.16.2024_9.35.06_AM+4000963SHEETINDEX K-1 KITCHEN EQUIPMENT PLAN K-2 KITCHEN EQUIPMENT SCHEDULE K-4 KITCHEN MECHANICAL ROUGH -IN PLAN P0.5 PLUMBING NOTES P1.0 PLUMBING WASTE & VENT P1.5 PLUMBING WATER VICTOR TAVERN EDMONDS 550 MAIN STREET, SUITE#100 EDMONDS, WA 98020 OKANO PICARD STUDIO General Notes • IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS TO VERIFYTHE ACTUAL SPACE AND MECHANICALREQUIREM ENTS OF ALL ITEMS SHOW AS FUTURE, N.I.C., SUPPLIED BY "OTHERS", ETC. WITH THE OWNER PRIOR TO ROUGH -IN AND CONNECTION • THE GENERAL CONTRACTOR SHALL IMMEDIATELY INFORM CMA RESTAURANT SUPPLY & DESIGN PROJECT MANAGER AND THE OWNER OF ANY RED LINES, CORRECTIONS, ETC. ON THE PERMIT PLANS AND OF ANY INSPECTION CORRECTIONS REQUESTED CONCERNING THESE DRAWINGS OR EQUIPMENT AS LISTED FOR THIS PROJECT. • THE GENERAL CONTRACTOR SHALL PROPERLY SEAL ALL WALL AND FLOOR PENETRATIONS AFTER THE INSTALLATION OF RELATED EQUIPMENT AND FURNISHING. • IT SHALL BE NOTED BY THE GENERAL CONTRACTOR AND ALLSUB-CONTRACTORS THAT THIS SET OF PLANS AND THE INFORMATION CONTAINED WITH -IN IN NOW WAY RELIEVES SAID PARTIES OF THEIR RESPONSIBILITIY TO INVESTIGATE AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES, AND TO PERFORM ALL WORK TO THE HIGHEST STANDARDS. • THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR, CEILING, WALL AND ROOF PENETRATIONS AND FIRE RATED SHAFTS FOR EXHAUST DUCTWORK. • IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROVIDE WEATHER PROTECTION FOR ALL ROOF AND ALL WALL PENETRATIONS PRIOR TO AND DURING THE INSTALLATION OF EQUIPMENT AND FURNISHINGS. • SUITABLE WALL BACKING AS SHOWN ON THESE PLANS AND AS REQUIRED BY THE OWNER SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. • THE EXHAUST SYSTEM SHALL BE SUBJECT TO A PERFORMANCE TEST AS REQUIRED PRIOR TO ISSUANCE OF BUILDING PUBLIC OCCUPANCY BY LOCAL BUILDING OFFICIALS. • PLANS FOR WALK-IN COOLER SHALL BE SUBMITTED PRIOR TO CONSTRUCTION. • THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE EQUIPMENT CUT SHEET BOOK SUPPLIED BY CMA RESTAURANT SUPPLY & DESIGN, INC. AND BY THIS REFERENCE IS MADE A PART HEROF. ROOF / REMOTE LOCATION SEE ARCHITECTS / ENGINEERS DRAWINGS 63 65 112 VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS CM N O N 1 r C) �W V ) W M N O N 1 CV �I H W Z O U H to Z O U UNPUBLISHED WORK CQ2022 CMA. INC. O O CV O O 'T'-- 00 � � O O O O l/1 U •r vi 0 O E � W i I 00N 0011- co L� co co u') o c14 N U U O i ' I U z z CD Cn ui 0 Q 0 0 0 J 0 I >, i � � n C a Z Y CA Q U m Q c VJ z J I W �a � � w Z Q z W W Z W U Date: 10-25-2022 JIG WINTER Scale: 1 /4"=1'-0" Project #: 1652 General Notes 1. THE ELECTRICAL CONTRACTOR SHALL SLIPPY AND INSTALL SEAL-TITE FLEX CONDUIT TO ALL FOOOD SERVICE EQUIPMENT IN DAMP AREAS, I.E. SCULLERY, BAR, ROOF, ETC. FLEX CONNECTIONS AT ALL FANS ON THE ROOF SHALL BE OF EXTRA LENGTH TO ALLOW FULL FAN REMOVAL FOR THE EASE OF CLEANING. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND LABELING. 3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS IN A CONVENIENT ACCCESSIBLE LOCATION ATTHE POWER BOX FOR EACH ICE MACHINE HEAD. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL AVAPOR-PROOF SWITH AT EACH BLOWER COIL IN THE WALK-IN COOLER (#96). 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A 48" MINIMUM CORD AND PLUG FOR EACH PIECE OF EQUIPMENT SO NOTED. USE 90 DEGREE ELBOW OUT OF UNIT. 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR HOOK-UP OF ATHERMOSTAT, SOLENOID, BLOWER COIL AND COMPRESSOR FOR EACH REFRIGERATED UNIT. MAGNETIC STARTERS AND/OR THERMAL PROTECTORS SHALL BE INCLUDED AS NECESSARY. 7. IT SHALL BE THE RESPONSIBILITY OF "OTHERS" TO INTERCONNECT THE HOOD FIRE PROTECTION SYSTEMS TO THE BUILDING FIRE DETECTIONS SYSTEMS AS REQUIRED. 8. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL TO EACH PIECE OF ROOF -TOP EQUIPMENT (FANS, MOTORS, COMPRESSORS, CONDENSORS, ETC.) ASEPARATE WEATHER -PROTECTED DISCONNECT SWITCH. 9. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING AND ELECTRICAL CONTRACTORS TO MAKE ALL REQUIRED WATER, GAS, DRAIN AND ELECTRICAL CONNECTIONS FOR ALL MAKE-UP AIR SYSTEM UNITS. 10. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER SUPPLIED COMPUTER / COMMUNICATION CABLES AS PER OWNERS' DIRECTION. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE AN INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF ROOFTOP ELECTRICALLY POWERED EQUIPMENT. 12, THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO SHEETROCK/ FRP INSTALLATION. 13. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT AND JUNCTION BOXES AT EACH CASH REGISTER TERMINAL SO AS TO INTERCONNECT ALL UNITS TO EACH OTHER AND TO THE CENTRAL PROCESSING TERMINAL. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR EXACT LOCATIONS OF ALL TIE-IN UNITS. 14. COMMUNICATION CABLES ARE SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. 15. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER SUPPLIED COMPUTER / COMMUNICATION CABLES AS PER OWNERS' DIRECTION. 16. ELECTRICAL CONTRACTOR SHALL PROVIDE AN INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF ROOFTOP ELECTRICALLY POWERED EQUIPMENT. 17. THE ELECTRICAL CONTRACTOR SHALL PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN EXHAUST HOOD FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED BY LOCAL CODES AND AUTHORITIES. 18, ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE DONE IN COPPER. 19. THE PLUMBING CONTRACTOR SHALL PROVIDE CLEANOUTS AT 1ST ELBOW ON EACH WALK-IN BLOWER COIL DRAIN. 20. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL DRAIN LINES FROM WALK-IN BLOWER COILS TO FLOOR SINKS. 21. THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL WATERLINE BACK CHECK VALVES AS REQUIRED PER CODE. 22. IT SHALL BE THE RESPONSIBILTY OF PLUMBING CONTRACTOR TO COMPLY WILL ALL LOCAL CODES CONCERNING GAS VALVE REGULATOR VENTING. 23. PRESSURE REGULATOR'S FOR GAS COOKING EQUIPMENT ARE SUPPLIED BY CMAAND INSTALLED BY PLUMBING CONTRACTOR PER CODE AND MANUFACTURER'S SPECIFICATIONS. 24. THE OWNER'S VENDOR OF CHOICE SHALLSUPPLY AND INSTALL A CO2 STORAGE CANISTER IN THE LIQUOR STORAGE ROOM, AN EXTERIOR FILL VALVE AND ALL CO2 UNITS SHALL BE SUPPLIED AND INSTALLED BYTHE VENDOR. z -$ �V Q n 1 1 C0 1 Iv- Q w ♦ ^ w CV IN 1 1 LO Illl- w U) O Illl- U u) O U PROVIDED BY ELECTRICAL Description W N U 7 E a 0 O CY Y Q 2 SPARE NUMBERS PLUMBING ! Notes N 7 F (7 a m W Y d 01 o > m t a u 07 o U x o 0 0; R 1 2 3 4 5 6 7 8 9 10 11 SPARE NUMBER 12 SPARE NUMBER 13 SPARE NUMBER 14 SPARE NUMBER 15 SPARE NUMBER 16 SPARE NUMBER 17 SPARE NUMBER 18 X 1 SLUSHY MACHINE 12.0 115 1 DCO 19 X 1 ICE MACHINE 5.0 115 1 DCO 1/2" 1" INDIRECT WASTE 20 X 1 DIE WALL AND COUNTER TOP 21 X 2 MIX S INK 1/2" 1/2" 1 1/2"' INDIRECT WASTE 22 X 2 JOCKEY BOX WITH COLD PLATE 1" INDIRECT WASTE 23 X 2 SODA DISPENSING GUN 3.0 115 1 DCO 1/2" 24 X 2 MIX RAIL 25 X 2 DRAINBOARD WITH REFRIGERATED BASE X 115 1 DCO 1/2, INDIRECT WASTE 26 X 2 HAND SINK 1 1/2" 1/2" 1 1 1/2"' DIRECTWASTE 27 X 2 TRASH SECTION 28 X 3 WORK TABLE 29 X 1 DRAIN BOARD WITH GLASS RACK STORAGE 1/2" 30 X 1 GLASS WASHER X 208 1 DCO 1/2" 1" INDIRECT WASTE, VERIFY REQUIREMENTS WITH OWNER 31 X 1 DUMP SINK 1 1/2" INDIRECTWASTE 32 X 1 ISLAND COUNTER 33 X 2 BACK BAR COOLER X 115 1 DCO NEMA 5-15P 34 X 1 POINT OF SALE TERMINAL 3.0 115 1 DCO DEDICATED / ISOLATED, VERIFY REQUIREMENTS WITH OWNER 35 X 3 TICKET PRINTER 3.0 115 1 DCO DEDICATED / ISOLATED, VERIFY REQUIREMENTS WITH OWNER 36 X 2 BEER TOWER WITH RINSERS 1/2" 1" INDIRECT WASTE 37 SPARE NUMBER 38 SPARE NUMBER 39 SPARE NUMBER 40 SPARE NUMBER 41 SPARE NUMBER 42 SPARE NUMBER 43 SPARE NUMBER 44 SPARE NUMBER 45 SPARE NUMBER 46 SPARE NUMBER 47 SPARE NUMBER 48 SPARE NUMBER 49 SPARE NUMBER 50 X 1 FRONT COUNTER 51 X 3 HEAT LAMP 0.25 115 1 JBOX 52 X 1 TRASH CAN 53 X 3 PAN TOP REFRIGERATOR 6.5 115 1 DCO NEMA 5-15P 54 X 1 WORK TABLE 55 X 1 TOASTER X 208 1 SCO X)m 56 X 3 WALL MOUNT HAND SINK 1 1/2" DIRECT WASTE 57 X 3 FAUCET 1/2" 1/2"' 58 X 3 HAND SOAP AND TOWEL DISPENSER 59 X 2 PREP SINK 1 1/2" INDIRECT WASTE 60 X 2 FAUCET 1/2" 1/2" 61 X 1 CLASS I EXHAUST HOOD 3.0 115 1 JBOX FOR LIGHTS 62 X 1 CLASS I EXHAUST DUCTWORK 63 X 1 CLASS I EXHAUST FAN X X X JBOX SEE MECHANICAL DRAWINGS 64 X 1 MAKE-UP AIR DUCTWORK 65 X 1 MAKE-UP AIR FAN X X X JBOX X X SEE MECHANICAL DRAWINGS 66 X 1 FIRE SUPPRESSION SYSTEM NOTE #7 67 X 1 STAINLESS STEEL WALL FLASHING 68 X 1 DOUBLE STACK CONVECTION OVEN 3.4 115 1 DCO 3/4" XXX 69 X 1 RANGE 3.4 115 1 DCO 3/4" 236,000 70 X 1 POT FILL FAUCET 1/2" 71 X 1 GRIDDLE 3.4 115 1 DCO 3/4" X 72 X 1 REFRIGERATED EQUIPMENT STAND X 115 1 DCO 73 X 3 FRYER 3/4" X 74 X 1 WORK TOP FREEZER X 115 1 DCO NEMA 5-15P 75 X 1 WORK TABLE 76 X 2 WALL SHELF 77 X 6 STAINLESS STEEL CORNER GUARD 78 SPARE NUMBER 79 SPARE NUMBER 80 SPARE NUMBER 81 SPARE NUMBER 82 SPARE NUMBER 83 SPARE NUMBER 84 SPARE NUMBER 85 SPARE NUMBER 86 SPARE NUMBER 87 SPARE NUMBER 88 SPARE NUMBER 89 SPARE NUMBER 90 X 1 REACH -IN FREEZER X 115 1 DCO NEMA 5-15P 91 X 1 WORK TABLE 92 X 1 WALK-IN COOLER 3.0 115 1 JBOX FOR LIGHTS 93 X 1 BLOWER COIL 2.4 115 1 JBOX 314" INDIRECT WASTE 94 X 1 COMPRESSOR 9.6 208 3 JBOX 95 X 1 WALK-IN COOLER SHELVING 96 X 2 MOBILE PAN RACK 97 X 1 BEER POWER PACK X X X X VERIFY REQUIREMENTS WITH OWNER 98 X 1 BEER DISPENSING SYSTEM 99 X 1 WATER HEATER 100 X 1 SOILED DISH TABLE WITH PRE -RINSE SINK 2" DIRECT WASTE 101' X 1 SLANT RACK SHELF 102 X 1 RACK STORAGE SHELF 103 X 3 TRASH CAN 104 X 1 PRE -RINSE FAUCET 1/2" 1/2" 105 X 2 QUICK DRAIN 1" INDIRECT WASTE 106 X 1 STAINLESS STEEL WALL FLASHING 107 X 1 DISHWASHER X X X JBOX 3/4" 2" INDIRECT WASTE, VERIFY REQUIREMENTS WITH OWNER 108 X 1 FLOOR TROUGH 2" DIRECT WASTE 109 X 1 CLEAN DISH TABLE WITH THREE COMPARTMENT SINK 1 1/2" DIRECT WASTE 110 X 2 FAUCET 3/4" 3/4" ill X 1 WIRE WALL SHELVING 112 X 1 GREASE INTERCEPTOR 113 X 1 CLEAN DISH SHELVING 114 X 1 DRY STORAGE SHELVING 115 X 1 EMPLOYEE LOCKERS 116 X 1 MOP SINK 1 1/2" DIRECTWASTE 117 X 1 FAUCET 1/2" 1/2" 118 X 1 MOP / BROOM HANGER SHELF 119 X 1 ICE MACHINE 9.5 208 1 JBOX 1/2" 1" INDIRECT WASTE 120 X 1 ICE BIN 1" INDIRECT WASTE 121 X 1 FLOOR TROUGH 2" DIRECT WASTE X 1 BAG N BOX RACK E23 X 1 BULK CO2 TANK NOTE #24 UNPUBLISHED WORK ©2022 CMA. INC. 0 O CV 0 Q r C m / VJ Iz U) O ate-+ M U) 3: U �� vi 0 O �E LLI LO M CO CV co I M � 0 0 N c� v U U 0 0 i U Z Z I U) Lu M I e z M 0 0 m E I J o0j U n Z Q E I a U I Q 0 i �� Lu. V0> J Z J W w L LI I C) Lu U U) I- Z Lu a Lu z Lu U Date: 6-6-2022 JG WINTER Scale: NONE Project #: 1652 K=2 PLUMBING NOTES. 1. IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO SIZE, SUPPLY AND INSTALL A GREASE INTERCEPTOR/ TRAP IF ONE IS REQUIRED. 2. ALL FIRE PROTECTION SYSTEM GAS SHUT-OFF VALVES SHALL BE SUPPLIED BY THE OWNER AND INSTALLED BY THE PLUMBER. 3. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR THE FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECT'S PLAN SET FOR ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 4. ALL PLUMBING ROUGH -IN WORK AND FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY CMA RESTAURANT SUPPLY & DESIGN SHALL BE PERFORMED BY THE PLUMBING CONTRACTOR. 5. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL INSULATION MATERIAL ON ALL DRAIN LINES FROM ICE BINS, ICE PANS, ETC. SO AS TO ELIMINATE CONDENSATION FORMATION. 6. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL PLUMBING -TYPE MATERIALS INCLUDING VALVES, TRAPS, LINE STRAINERS, FLOOR SINK COVERS, PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 7. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE FLOOR PENETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS IN THE FLOOR. 8. THE GENERAL CONTRACTOR SHALL SUPERVISE THE LOCATION OF ALL FLOOR DRAINS ON THE PROJECT SO AS TO ENSURE THE BEST SLOPE POSSIBLE OF THE SURROUNDING FLOOR TO THESE DRAINS. 9. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE RUN IN COPPER. 10. PLUMBING CONTRACTOR TO SUPPLY WATER PRESSURE REDUCING VALVE SET AT 20 PSI FOR EACH DISH WASHER AND GLASS WASHER. PLUMBING LEGEND o CW-COLD WATER o F CW-COLD WATER - FILTERED o HW-HOT WATER ® CLOSED DRAIN - DIRECT WASTE F E-1 Fs 12" X 12" FLOOR SINK - INDIRECT WASTE ® NATURAL GAS FD O FLOOR DRAIN ROOF / REMOTE AREA 78120 DDCCCI IDE DC('I II AT()D GAS LIIv SHUT-OFF VA RESTRAINING CAB FLEXIBLE C BY K.E.C. QUICK DISCONNECT GAS LINE SODA LINE DETAIL SCALE: NONE VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS co CV O CV 00 I N Iv— ui U) ui Of M N O CV co I Iv— Iv— ui C) ui Of M N O CV 1 CV H W C/) Z O H U ry H z 0 U UNPUBLISHED WORK QC 2022 CMA. INC. O O N O O r 00 4-1 C: O U O U U -� vi .� > G � O 0 Ln LO LU LO co co co LO o� U U 0 U Z z cn I i Lu LJ 0 Q M >_ 00 F) E J o 0 U � T ^ C Cz 7 c � Z Q Y � U E z N /� V/ w CD Z J LLJ W z Q z O ry Q U_ z Q U Lu 75 z w U Date: 11-1-2022 JG WINTER Scale: 1 /4"=1'-0" Project #: 1652 KM4 General Notes GENERAL NOTES - MECHANICAL PLUMBING NOTES NON-STRUCTURAL MECHANICAL COMPONENT NOTES I. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. I. WATER HAMMER ARRESTERS: PROVIDE AT THE END OF I. THE COMPONENT IMPORTANCE FACTOR (IP) FOR ALL HOT AND COLD WATER LINES SERVING TWO OR MORE NON-STRUCTURAL COMPONENTS SHALL BE: 2. REFER TO ARCHITECTURAL AND STRUCTURAL FIXTURES. SIZE IN ACCORDANCE WITH PLUMBING AND IP = 1.0 DRAWINGS FOR LOCATIONS OF EXPANSION/SEISMIC DRAINAGE INSTITUTE (PDI) REQUIREMENTS. 2. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE JOINTS. PROVIDE EXPANSION/SEISMIC JOINTS FOR 2018 UNIFORM PLUMBING CODE AND FROM THE AMERICAN PIPING AND DUCTWORK CROSSING EXPANSION/SEISMIC 2. REDUCED PRESSURE BACKFLOW PREVENTERS (RPBP): SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD 7-05. THE JOINTS WHERE NOTED ON THE DRAWINGS. PROVIDE INDIRECT DRAIN PIPING FROM RPBP TO CONTRACTOR SHALL REFER TO THE ABOVE FOR NEAREST DRAIN. INSTALL FUNNEL AT RPBP IF REQUIRED. ADDITIONAL INFORMATION, EXCEPTIONS, AND FURTHER 3. UNLESS OTHERWISE SPECIFIED, THE GENERAL DESCRIPTIONS. THE CONTRACTOR SHALL ADHERE TO CONTRACTOR (GC) SHALL BE RESPONSIBLE FOR 3. ACCESS PANELS: PROVIDE IN NON ACCESSIBLE REQUIREMENTS AND AS SUCH, SHALL BE INCLUDED WITHIN PAINTING, CUTTING, AND PATCHING OF EXISTING CEILINGS AND WALLS FOR VALVES, WATER HAMMER BID. FLOORS, WALLS, AND PARTITIONS IN THE EXISTING ARRESTERS, CLEANOUTS, AND OTHER ITEMS THAT BUILDING. REQUIRE ACCESS TO PROPERLY MAINTAIN OR SERVICE 3. 2018 BUILDING CODE, SCOPE: ARCHITECTURAL, THE BUILDING. MECHANICAL, ELECTRICAL, AND NON-STRUCTURAL 4. REFER TO STRUCTURAL DRAWINGS FOR ALLOWABLE COMPONENTS THAT ARE PERMANENTLY ATTACHED TO METHODS/LOADS FOR HANGING PIPING/DUCTS FROM 4. CLEANOUTS: PROVIDE AT THE BASE OF SANITARY STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS STRUCTURAL MEMBERS. VERIFY WITH THE LANDLORD DRAINAGE, PROCESS WASTE, AND RAINLEADER SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE REGARDING APPROVED METHODS OF ATTACHMENT. CONDUCTORS. EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7-05, EXCLUDING CHAPTER 14 AND APPENDIX IIA. 5. DO NOT RUN ANY PIPES OVER ANY ELECTRICAL PANEL 5. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR OR SWITCHGEAR. COORDINATE PIPE LOCATIONS TO FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, 4. 2018 BUILDING CODE, CONTRACTOR RESPONSIBILITY: THE AVOID ELECTRICAL PANELS. COILS, TRAPS, CONTROL VALVES, AND OTHER CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPONENTS TO ALLOW DISASSEMBLY FOR CONSTRUCTION OF A SEISMIC -FORCE -RESISTING SYSTEM, 6. PROVIDE MANUFACTURER'S RECOMMENDED AND CODE MAINTENANCE. DESIGNATED SEISMIC SYSTEM, OR SEISMIC -RESISTING - REQUIRED CLEARANCES AROUND PIECES OF COMPONENT LISTED IN THE STATEMENT OF SPECIAL EQUIPMENT. PIPING AND CONDUIT SHALL NOT 6. PROVIDE PIPING MATERIALS PER SPECIFICATION PRIOR INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT INTERFERE WITH REQUIRED ACCESS. TO ORDERING AND INSTALLING. OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE 7. EQUIPMENT LAYOUT IS BASED ON EQUIPMENT LISTED IN 7. PROVIDE AN INSULATED COPPER TRACER WIRE OR SYSTEM OR COMPONENT. THE CONTRACTOR'S EQUIPMENT SCHEDULES. ANY OTHER EQUIPMENT USED OTHER APPROVED CONDUCTOR ADJACENT TO STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE IS SUBJECT TO MEETING PERFORMANCE UNDERGROUND NONMETALLIC (PLASTIC) PIPING. FOLLOWING: REQUIREMENTS OF LISTED EQUIPMENT. MAKE ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR NECESSARY ADJUSTMENTS TO ASSURE OTHER THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT A. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL EQUIPMENT WILL FIT IN AVAILABLE SPACE AND WILL NOT EACH END OF THE PIPING. THE TRACER WIRE SHALL NOT REQUIREMENTS CONTAINED IN THE STATEMENT OF EXCEED WEIGHT AND ELECTRICAL REQUIREMENTS. BE LESS THAN NO. 18 AWG AND THE INSULATION TYPE SPECIAL INSPECTIONS; SHALL BE SUITABLE FOR BURIAL. 8. ALL PIPING SHALL BE PROVIDED WITH SEISMIC B. ACKNOWLEDGEMENT THAT CONTROL WILL BE RESTRAINTS IN ACCORDANCE WITH IBC SEISMIC DESIGN 8. PROVIDE 12" LONG 1/2" WIDE FLUORESCENT ORNGE EXERCISED TO OBTAIN CONFORMANCE WITH THE CATEGORY D. CONTRACTOR SHALL HIRE A LICENSED TAPE AT CONCEALED VALVE LOCATIONS. CONSTRUCTION DOCUMENTS APPROVED BY THE PROFESSIONAL ENGINEER IN THIS STATE TO DESIGN BUILDING OFFICIAL; CATEGORY D. CONTRACTOR SHALL HIRE A LICENSED 9. UNLESS OTHERWISE NOTED, ALL WASTE PIPING TO BE PROFESSIONAL ENGINEER IN THIS STATE TO DESIGN SLOPED AT 1/4 ' - 1'-0" - 2% MIN C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE ANY NECESSARY ANCHORAGE, BRACING, ETC. FOR CONTRACTOR'S ORGANIZATION, THE METHOD AND MECHANICAL COMPONENTS TO COMPLY WITH IBC FREQUENCY OF REPORTING AND THE DISTRIBUTION OF SECTION 1621 AND ASCE 7-02 SECTION 9.6.3. THE REPORTS; 9. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN D. IDENTIFICATION AND QUALIFICATIONS OF THE DESIGNED TO COMPLY WITH STATE ENERGY CODE. PERSON(S) EXERCISING SUCH CONTROL AND THEIR DIVISION 22 AND/OR 23 IS RESPONSIBLE FOR CORRECT ENERGY CODE NOTES POSITION(S) IN THE ORGANIZATION. INSTALLATION OF ENERGY CONSERVATION MEASURES. FOR CORRECT INSTALLATION OF ENERGY I. MOTORS: COMPLY WITH MINIMUM FULL LOAD 4. RESPONSIBILITIES: CONSERVATION MEASURES. EFFICIENCIES LISTED IN ENERGY CODE ENFORCED BY AHJ. A. HANGERS AND SEISMIC BRACING FOR MECHANICAL 10. PLUMBING VTR'S SHALL BE A MINIMUM OF 5 FEET FROM SYSTEMS SHALL BE DESIGNED AND SPECIFIED BY FIRE RATED WALLS AND 15 FEET AWAY FROM OUTSIDE 2. PIPING INSULATION: COMPLY WITH THICKNESSES AND CONTRACTOR. REFER TO THE MECHANICAL DRAWINGS AIR INTAKES. TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ FOR LOCATIONS OF EQUIPMENT AND HUNG UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. MECHANICAL SYSTEMS AS STRUCTURAL DRAWINGS DO II. COORDINATE ROOF PENETRATIONS WITH STRUCTURAL NOT SHOW THE LOCATIONS OF MECHANICAL BEAMS. 3. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER EQUIPMENT, DUCTWORK, PIPING, AND OTHER 12. PROVIDE COPPER CONDENSATE DRAINAGE PIPING PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. COMPONENTS. FROM MECHANICAL EQUIPMENT WITH INSULATED PIPING B. COORDINATE THE SUPPORT SYSTEMS AND DESIGN AND WITH RUNNING TRAP. ROUTE CONDENSATE PIPING 4. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO LOADS FOR HUNG PIPING AND OTHER MECHANICAL TO CODE ALLOWED RECEPTOR. THE BUILDING OWNER PER ENERGY CODE ENFORCED BY SYSTEMS (INCLUDING COMBINED MULTIPLE PIPE RUNS) THE LOCAL AHJ. WITH THE GENERAL CONTRACTOR AND THE STEEL AND No. Revision/Issue Date 13. PENETRATIONS SHALL BE PROPERLY SEALED WITH 5. MECHANICAL SYSTEMS COMMISSIONING AND WOOD JOIST MANUFACTURERS IN ADDITION TO OTHER EXPANDING FOAM AND FILLED WITH CONCRETE FILL, OR COMPLETION REQUIREMENTS: TEST SYSTEMS TO TRADES THAT MAY BE IMPACTED. Firm Name and Address AS APPLICABLE PER BUILDING CODE(S). ENSURE THAT BUILDING SYSTEMS HAVE BEEN DESIGNED, STATE MECHANICAL INSTALLED, AND FUNCTION PROPERLY, EFFICIENTLY, 8706 S 222ND ST 14. COORDINATE UTILITIES WITH FINAL FIELD CONDITIONS. AND CAN BE MAINTAINED IN ACCORDANCE WITH THE KENT, WA 98031 CONTRACT DOCUMENTS IN ORDER TO SATISFY THE 15. CLEANOUTS SHALL BE FLUSH WITH FINISHED FLOOR BUILDING OWNER'S DESIGN INTENT AND OPERATIONAL AND LOCATED WHERE SHOWN ON THE PLANS. REQUIREMENTS PER ENERGY CODE ENFORCED BY THE ALTERNATE FLOOR CLEANOUT LOCATIONS PROPOSED LOCAL AHJ. SHALL BE APPROVED BY THE ARCHITECT PRIOR TO REVISING 6. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN DESIGNED TO COMPLY WITH ENERGY CODE ENFORCED BY THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR Project Name and Address CORRECT INSTALLATION OF ENERGY CONSERVATION VICTOR TAVERN MEASURES 550 MAIN ST SUITE# 100 EDMONDS WA 98020 MECHANICAL EQUIPMENT INSTALLATION NOTES I. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. Project Sheet VICTOR TAVERN P005 Date OCTOBER 20, 2025 Scale NONE SPECI FICATION AN D SU BM ITTAL GU 2 35/50 GPM Grease Interceptor for Indoor Use 23 35' .aogogosos�e 89 cm os ( ) Eva�So'ogsEo��S�gogo $goSofir ogo ogog�$ s�ggs'Te �SS�SSgS� �geSig Soo .� (ism) aoogosoa�ogog0000� ssssga a 13-3/4" gop5op5 �oFa' $o. (35 cm) 8-3/4" I (22 cm) Thls unit is certified to ASME A112.14.3 (Type C) and CSA B481.1 at two different flow rates and includes the internal flow '4' controls for both. External flow control with vent not required. SUBMITTAL Standard Location: indoor Installation: above/below grade Flow Rates / Grease Capacities: 35 GPM (2.2 L/s) / 130.5 lbs. (59.2 kg) 50 GPM (3.2 L/s) / 127.6 lbs. (57.9 kg) Solids Capacity: 1.8 gal. (6.8 L) Liquid Capacity: 20 gal. (75.7 L) Weight: 49 lbs. (22.2 kg) Connections: 3' (75 mm) and 4' (100 mm) plain end Cover. bolted gas/water tight polypropylene with 1,000 lb. load rating when unit is buried with FCR1 riser Satisfies Miami DERM 99% efficiency requirements when at least 2 units are installed in series Options ❑ -FO: fixed outlet diffuser ❑ FCRI (xl): > 2-1/8' -12' field cut riser ❑ FCRI (x2): > 12' - 24' field cut risers ❑ Ccl: membrane clamping collar kit (requires FCRI riser) ❑ PPI: pumpout port kit ❑ SGK2: support gusset kit ❑ PLAIN-EA-24:2' (50 mm) plain end fitting ❑ FPT-EA-34:4' x 3' (100 mm x 75 mm) FPT fitting ❑ FPT-EA-23: 3' x 2' (75 mm x 50 mm) FPT fitting Approval Signature: Date: Company. Specifying Engineer: Engineering Firm: TIE INT( BUILDINC SANITAI Page 1 of 4 Installation Instructions Installation instructions and additional installation components are included with the instructions interceptor. Read all instructions prior inside to installation. This interceptor is intended to be installed by a licensed plumber in conformance with all local codes. When Installing Interceptor Inside If your dishwashing sinks) --- discharges into a floor O drain/sink (drain), you must regulate the flow into the drain to avoid an == overflow of water onto the kitchen floor. This can be done by installing a valve Fernco or similar rubber or flow flow restriction cap on restriction end cap the sink piping that discharges into the drain. See drawing for guidance. For detailed guidance on indirect connections, go to: webtools.schierproducts.com/Technical_ Data/indirect_Con nections.pdf Hydrostatic Slabs (or Pressure Slabs) When installed under a concrete slab subject to hydrostatic pressure hydrostatic slab (slab designed to withstand upward lift, usually caused by hydrostatic pressure) interceptor watertight must be enclosed in a concrete vault watertight concrete vault. High Temperature Kitchen Water cold water supply line high temperature effluent ( > 150o F) approved backflow prevention assembly DTV (drain water tempering valve) Interceptor Interceptor indirectly directly connected If water is entering the interceptor at excessive temperature (over 1500 F), a drain water tempering valve (DTV) and approved backflow prevention assembly must be installed. Most state and local plumbing codes prohibit water above 1500 F being discharged into the sanitary sewer. Water above 1500 F will weaken or deform PVC Schedule 40 pipe, poly drainage fixtures like interceptors and erode the coating of cast iron (leading to eventual failure). ODOR ALERT! Do not install air gap on outlet side of interceptor. I �I I -I NI / I \ Page 2 of 4 z�( VICTOR TAVERN FIXTURE SCHEDULE FIXTURE CITY DESCRIPTION PIPE SIZES FIXTURE UNITS COLD HOT WAST VEN WATER WATER WASTE WASTE 26 & 56 Hand Sinks 5 Wall Mount & Drop In Hand Sinks FBO 1/2" 1/2" 2" 1-1/2" 1.5 7.5 2 10 *59 & 100 Prep Sinks 3 e 1ng Si O ain I to Sink 1/2" 1/2" 1-1/2" * 1.5 4.5 2 6 21 Mix Sink 2 Drop In Mix Sinks FBO / Drain into Floor Sink 1/2" 1/2" 1-1/2" * 1.5 3 2 4 *109, 3 Comp Sink 1 Free Standing 3 Comp Sink W/ 2 Faucets FBO 1/2" 1/2" 2" 1-1/2" 1.5 3 2 4 7Glass Rinser 1 Glass Rinser FBO/ Drain into Floor Sink 1/2" * 1-1/2" *36 Pitcher Rinsers 2 Pitcher Rinsers FBO / Drain into Floor Sink 1/211 * 1" * 0.5 1 1 1 30Glass Washer 1 GlassWasher FBO / Drain into Floor Sink * 1/211 1" * 0.5 0.5 1 1 *107 Dishwasher 1 Dishwasher FBO / Drain into Floor Sink * 3/4" 2" * 1.5 1.5 2 2 119Ice Machine 1 Ice Machine FBO/ Drain Into Floor Sink 1/211 * 1" * 1 1 1 1 * 116 Mop Sink 1 Mop Sink & Faucet FBO 1/211 1/211 3" 2" 3 3 3 3 * 108FIoorTrough 1 Floor Though FBO * * 2" 1-1/211 * * 2 2 121 Floor Trough 1 Floor Though FBO * * 2" 1-1/211 * * 2 2 *Floor Drain 4 Sioux Chief FinishLine 832-2PNR Floor Drain * * 2" 1-1/2" 0 0 2 8 RPBP 3 Watts LF0091/2" 1/2" 1/2" * * * OR 0 0 * Floor Sinks 3 59 Prep Sinks, 36 Pitcher Rinsers, 100 Prep sink & 107 Dishwasher ProFlo 12x12x6 Floor sink PF906K * * 2" 1-1/2" 0 0 0 0 Floor Sinks 3 21 Mix Sinks, 30 Glass Washer & 119 Ice Machine ProFlo 12x12x6 Floor sink PF906K * * 2" 1-1/2" 0 0 0 0 Hot Water Tank 1 Rheem ELD80-TB-TR 80gal 4.5kw 240v 1ph Water Heater W/ Circ Pump 3/4" 3/4" * * 0 0 0 0 25 44 * FIXTURES TO GREASE INTERCEPTOR WATER PIPE SIZE ( SIZED PER UPC 2018 TABLE 610.4) 1" WATER @ 40-60 PSI = 39 WFU WASTE & VENTING PIPING SHALL BE: ABS OR PVC PIPE AND DOMESTIC WATER PIPING SHALL BE: COPPER OR PEX PIPE ALL DOMESTIC WATER PIPING WILL BE INSULATED IN ACCORDANCE WITH WASHINGTON STATE 2018 ENERGY CODE WASTE PIPE SIZE ( SIZED PER UPC 2018 TABLE 702.1) 2" VERTICAL 3" HORIZONTAL VTR General Notes REVISE BACK OF HOUSE KITCHEN 3 ADDING SCHIER G132 GREASE 1.16.24 INTERCEPTOR DO TO LOW INVERT Revision to Add 2 Floor Drains, 2 1 Floor Sink & Show Soda Lines 2.27.2 On Page K-4 REVISE BACK OF HOUSE KITCHEN 1 TO ACCOMMODATE LOW GREASE 1.16.2 LINE INVERT No. Revision/Issue Date Firm Name and Address STATE MECHANICAL 8706 S 222ND ST KENT, WA 98031 Project Name and Address *ALL WTR CLOSET VICTOR TAVERN TO BE 35" WASTE 550 MAIN ST SUITE# 100 EDMONDS WA 98020 *ALL DRAINS TO SINKS. TO BE 2" WASTE WITH 1-112" TRAP ARMS CLEAN OUTS PER CODE Project Sheet VICTOR TAVERN Date OCTOBER 20, 2025 • Scale NONE V ThermOmegaTech BENEFITS • Compliant with drain temperature limitations of plumbing codes • Prevents damage to PVC piping due to over -temperature conditions • Self-operating, no power or signal required • Minimizes water waste • Easy to install • Adaptable to almost any drain size DESIGN FEATURES • Exclusive Thermoloid® thermal actuator • Rugged, clog resistant valve design • Install using standard pipe fittings and tools • Operates in any orientation • Modulates to conserve cooling water • Effluent tempering capacity limited only by cold water flow rate through DTV APPLICATIONS The DTV can be used in applications where a high temperature discharge flow to a drain/sewer must be tempered with cold water. Examples: • Humidifier discharge to sewer/drain • Commercial dishwashers/warewashers • Boiler blowdown drain lines • Autoclave discharge • Any excessively hot effluent flow to sewer/drain OPERATION The DTV is installed into the drain line such that the hot effluent passes over the thermal actuator of the DTV and this thermal actuator controls the cold water inlet port. If the hot effluent is above the specified set -point, the DTV opens to allow injection of cold water. As the hot effluent cools, the DTV automatically modulates to reduce the cold water inlet flow. At 10OF below the full open temperature, the cold water inlet is fully closed to conserve water. 1J af 41 1" DTV %" DTV %" DTV TYPICAL INSTALLATIONS Since the DTV is open only when the effluent exceeds the specified set -point temperature, it conserves water by automatically turning off cold water when not needed. 1-877-379-8258 1 www.ThermOmegaTech.com DTV DRAIN TEMPERING VALVE PARTS & MATERIALS DIMENSIONS & CAPACITIES ITEM DESCRIPTION MATERIAL 1 VALVE BODY Brass or 300 Series SS 2 THERMAL ACTUATOR 300 Series SS 3 OPERATING SPRING 300 Series SS 4 RAM -TYPE PLUG 300 Series SS 5 SEAT SEAL PTFE 6 PISTON 300 Series SS SAMPLE CALCULATION How much effluent can be tempered with a 1" DTV valve? 1) Flow capacity through cold water port of 1" DTV with Cv=4.0: CW gpm =Cv x sqrt pressure drop Assume 50 psig cold water pressure, drain pressure=0 psig CW gpm =4 x sqrt (50)=28.3 gpm Assume for this example: cold water temp=60°F (CT) hot effluent temp=212°F (HT) max. allowable drain temp =140°F (MT) 2) Maximum effluent flow (gpm) that can be tempered: CW x (MT-CT)/(HT-MT) MT -CT = 80 HT -MT = 72 Maximum effluent flow rate =28.3 x 80/72=31.4 gpm SIZE (NPT) L1 L2 Weight CV Maximum Inlet Maximum Cold Water Drain in mm in mm Lb Kg Water Pressure Temperature Inlet Connection 1/2" 1" 2.9 73 4.9 124 1.1 0.5 2.0 125 PSIG (8.6BAR) 250°F (121°C) 3/4" 1" 5.9 149 7.9 200 1.2 0.5 2.0 1" 1-1/4" 5.8 148 7.4 187 1.5 0.7 4.0 ORDERING Part Number' Description 325-000000-XXX 'h" DTV Valve (Brass) 325-100000-XXX h" DTV Valve (Stainless Steel) 326-000000-XXX %" DTV Valve (Brass) 326-100000-XXX %" DTV Valve (Stainless Steel) 327-000000-XXX 1" DTV Valve (Brass) 327-100000-XXX 1" DTV Valve (Stainless Steel) NOTES 1. Full open temperatures "XXX" available: 120°F, 125°F, 130°F, and 140oF (48.9°C, 51.7°C, 54.4°C, and 600C). a. Other temperatures are available, consult our engineers for more information. b. Closing temperature is typically 10°F below opening temperature. 2. A water hammer arrestor must be installed directly behind the valve water supply inlet as shown in the sample installations when any type of check valve or back flow preventer is used per code. Failure to do so may cause permanent damage to the valve and void the warranty. 3. Warranty information disclosed at www.thermomegatech.com/terms-conditions/ A ThermOmegaTech", Inc. +` 353 Ivyland Road 1-877-379-8258 DTV �Warminster, PA 18974 www.ThermOmegaTech.com V 2/27/2023 Because of continuous improvements, ThermOmegaTwAIS Inc. reserves the right to change the design and specifications without notice C� I \ \Al I II \ \\\ II PREP I I I \ \ I I SINK HAND ISINK I \ 34� N� / I 3 COMP PREP C2 I I� SINK SINK yV I I I 3 COMP SINK =c , / n \ \ DISHWASHER DTV DRAIN \ N� 3 TEVQERwc 4 C PREP 2°N /2C HAN INK / \ SI SH - / I FLOOR SINK \ I I \ 3,4y AA TIE INTO EXISTING 3'4 tiw I I / c BLDG CW SYSTEM \ MIX \ _ C� SINK I I /BIZ HANDI SINJJ HAND \ I _ \ I` SINKIS LASS �I WASHER \ C I I I TIE INTO EXISTING SINK � HAND JJ BLDG CW SYSTEM FIXTURES n 1-9 REMOVED FROM SCOPE OF WORK 11 I Mix SINK J HOT WATER UMP EXPANSION T 3/4" RELIEF LI FULL SIZE TO M01 R-10 RIDGI INSULATI WATER HEATER DETAIL SCALE: NONE RESTRAINTS C z�( VICTOR TAVERN FIXTURE SCHEDULE FIXTURE QTY DESCRIPTION PIPE SIZES FIXTURE UNITS COL HO AS VE WATER LE WATER ALVAC WASTE E WASTE AL 6& 56 and Sins Wal Mount & Drop n Hand Sinks F O 1/2" 1/2" 2" 1-1/2" 1.5 7.5 2 10 *59 & 100 Prep Sinks 3 ree S ing p Sin BO rain In Floo Sink 1/2" 1/2" 1-1/2" * 1.5 4.5 2 6 21Mix Sink 2 Drop In Mix Sinks FBO/ Drain into Floor Sink 1/2" 1/2" 1-1/21' 1 1.5 3 2 1 4 *109, 3 Comp Sink 1 Free Standing 3 Comp Sink W/ 2 Faucets FBO 1/2" 1/2" 2" 1-1/2" 1.5 3 2 4 7Glass Rinser 1 Glass Rinser FBO / Drain into Floor Sink *36 Pitcher Rinsers 2 Pitcher Rinsers FBO / Drain into Floor Sink 1/2" * 1" * 0.5 1 1 1 30GIass Washer 1 GlassWasher FBO/ Drain into Floor Sink * 1/2" 1" * 0.5 0.5 1 1 *107 Dishwasher 1 Dishwasher FBO / Drain into Floor Sink * 3/4" 2" * 1.5 1.5 2 2 119Ice Machine 1 Ice Machine FBO/ Drain Into Floor Sink 1/2" * 1" * 1 1 1 1 * 116 Mop Sink 1 Mop Sink & Faucet FBO 1/2" 1/2" 3" 2" 3 3 3 3 * 108 Floor Trough 1 Floor Though FBO * * 2" 1-1/21' * * 2 2 121 Floor Trough 1 Floor Though FBO * * 2" 1-1/2" * * 2 2 *Floor Drain 4 Sioux Chief FinishLine 832-2PNR Floor Drain * * 2" 1-1/2" 0 0 2 8 RPBP 3 Watts LF0091/21' 1/2" 1/2" * * * * 0 0 * Floor Sinks 3 59 Prep Sinks, 36 Pitcher Rinsers, 100 Prep sink & 107 Dishwasher ProFlo 12x12x6 Floor sink PF906K * * 2" 1-1/2" 0 0 0 0 Floor Sinks 3 21 Mix Sinks, 30 Glass Washer & 119 Ice Machine ProFlo 12x12x6 Floor sink PF906K * * 2" 1-1/2" 0 0 0 0 Hot Water Tank 1 Rheem ELD80-TB-TR 80gal 4.5kw 240v 1ph Water Heater W/ Circ Pump 3/4" 3/4" * * 0 0 0 0 25 44 * FIXTURES TO GREASE INTERCEPTOR WATER PIPE SIZE ( SIZED PER UPC 2018 TABLE 610.4) 1" WATER @ 40-60 PSI = 39 WFU WASTE & VENTING PIPING SHALL BE: ABS OR PVC PIPE AND DOMESTIC WATER PIPING SHALL BE: COPPER OR PEX PIPE ALL DOMESTIC WATER PIPING WILL BE INSULATED IN ACCORDANCE WITH WASHINGTON STATE 2018 ENERGY CODE WASTE PIPE SIZE ( SIZED PER UPC 2018 TABLE 702.1) 2" VERTICAL 3" HORIZONTAL VTR Al ICE MACHINE z� \ TIE INTO EXISTING \ \ BLDG CW SYSTEM cw General Notes 3 Added DTV Drain Tempering Valve At Dishwasher 1.16.24 1 REVISE BACK OF HOUSE KITCHEN TO ACCOMMODATE LOW GREASE LINE INVERT 1 _16_2 No. Revision/Issue TDate Firm Name and Address STATE MECHANICAL 8706 S 222ND ST KENT, WA 98031 Project Name and Address VICTOR TAVERN 550 MAIN ST SUITE# EDMONDS WA 98020 // Project Sheet VICTOR TAVERN 1,05 Date OCTOBER 20, 2025 Scale NONE