Victor Tavern HGI Approval 1-26-24REVISION
Jan 25 2024
CITY OF EDMONDS
DEVELOPMENT Si'
T
CITY OF EDVIONDS
Grease Removal Equipment Application
Business Name: Victor Tavern
Address: 550 Main St, Edmonds, WA 98020
Date Submitted: 01.17.24
Suite No.: 100
Business Owner Victor Tavern Edmonds LLC Mailing Address: 2622 NW Ballard Ave, Ste A, Seattle,WA 98107
Contact Person/Title: Kara Samac - Director of Development
Days/Hours of Operation: Monday -Sunday: 11 AM - 10PM
Phone: 253.486.3500
Total Number of Meals Served Per Peak Hour (assume all seats filled): 108
Number of Seats: Dining: 65 Lounge/Bar: 73 Banquet Rooms: 18 Deck/Patio: 26
Building Occupancy Permit Capacity: 219 Health Dept. Permit Capacity TBD
Inventory of Kitchen Equipment and Plumbing Fixtures for this Establishment: (Grills,
burners, ovens, hoods, deep fat fryers, wok stations, soup kettles, sinks, pre -wash sinks,
dishwashers, disposers, mop sinks, floor drains, etc.) See attached equipment cut sheet
What proportion, if any, of the dishware used is of the disposable type? 5016 - only to go packaging
How is waste oillgrease handled, stored, and recycled/disposed?
Grease interceptor is cleaned out on a prevenative maintance scheudle by West Coast. Spent fryer oil
is collected and recycled through sequential.
Estimate gallons of waste oil/grease produced per month: 130
If recycled, by which company? Sequential
How are vent hoods cleaned and where does the cleaning waste go?
Hood vents are flushed clean and waste water is feed into a drain connected to interceptor.
Contact the Pretreatment Technician at 425-771-0237 ext. 1355 to discuss the
type and size of equipment you must install, and then complete the appropriate
[Revised 7/12/20221
REVISION
Jan 25 2024
CITY OF Tr'-'+. ydromechanical Grease Interceptor Sizing Worksheet
DEVELOPMENT' -
DEPAa�. •
Facility Name: Victor Tavern
Address: 550 Main St, Edmonds, WA 98020
Suite No.: 100
A Hydromechanical Grease Interceptor (HGI) plumbing permit is required. Contact the
Pretreatment Technician (425-771-0237 ext. 1355) if you have any questions regarding this
form. I.�- ��PrJ�.e�i w,kv� -%►nn� �r�►M���e{� N�
Dishwashers are not allowed to be connected to a HG .
Food disposers are not allowed in a facility served by a HGI and must be disabled or d b-a y
removed. Solids must be screened out and placed in the solid waste container.
Fixture Capacity in Cubic Fixture Capacity Drainage Load Flow Rate for
Inches in Gallons (75% of Total a 2-Minute
(L x W x D x no. of sinks) (Cu. In.— 231) Capacity) Drain Period
#1 22 x 24 x 12 x 3=19.008 c.i - 231 = 82 gal. 'x.75 = 22 gal. - 2 = 31 gpm
#2 20 x 20 x 14 x 1 = 4,800 c.i - 231 = 21 gal. x .75 = 16 gal. - 2 = 8 gpm
#3 24 x 24 x 6 x 1 = 3,456 c.i _ 231 = 15 gal. x .75 = 11 gal. - 2 = 5.5 gpm
- - machine W DTV drain tempering valve
#4 1, Auto Chlor AC 44 Dishwashing mac / p g
.49 gallons per rack
HGI #1— Total drainage flows from maximum of 4 fixtures .-S gpm 1
#1 x x x = _c.i _ 231 = gal. x .75 = gal. - 2 = gpm
. ---
#2 x x x = c.i - 231 =
gal.
x .75 =
gal.
- 2 = gpm
#3 x x x c.i - 231 =
gal.
x .75 =
gal.
- 2 = gpm
#4 x x_x = c.i - 231 =
gal.
x .75 =
gal.
- 2 = gpm
HGI #2 — Total drainage flows from maximum of 4 fixtures
gpm
#1 Hydromechanical Grease Interceptor Size (in
35 650
75
100 or greater
gpm)
[Revised 7/12/2022]
REVISION
Jan 25 2024
CITY OFfE>3f- DND5
]EVE aLs,=Wyffromechanical Grease Interceptor Size (in 11 35 75 ' 100 or greater
gpm)
If the calculated size is less than 35 gpm please circle the 35 gpm box.
The Minimum Hydromechanical Grease Interceptor size is 35 gpm as per City of Edmonds
Pretreatment Ordinance.
City may upsize for factors such as low temp/high volume dishwashing, if permitted, or
high oil/grease content on menu, etc.
----------------- t or City use only below this lire} --------------------------
Remarks: QvnprA-uiv. of A 14-e rnv,- ' bP- of- ASS .
Size Approved: SC) gpm Approved by:
Technician
Date: 1-d 6- a y
[Revised 7/12/2022]