APPROVED ENG-Sewer Pump Calculations-BLD2021-0985C �
ENGINEERING
250 4' Ave S Ste 200
Edmonds, WA 98020
Phone: (425)778-8500
Fax: (425) 778-5536
civil & structural
engineering & planning
RESUB
Mar 22 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Sewer Pump Calculations
Keck Residence
15722 72nd Ave W
Edmonds, WA 98026
0311112022
CIS Project No.: 21125.20
ENGINEERING DIVISION
APPROVED AS NOTED
L�//� 5/06/2022
CALCULATIONS REVIEWED
AND APPROVED BY:
MIKE DE LILLA, P.E.
CITY UTILTIIES ENGINEER
Keck Residence - CG #21125.20 March 11, 2022
Pump Calculations Page 1
This package contains:
- Flow Rate Calculations
- Headloss Calculations
- Pump Elevation Specifications
- Storage Calculations
- Cycling Calculations
- Buoyancy Calculations
- Pump Literature/Specifications
- 11x17 Water and Sewer Plan Sheet
The calculations contained herein demonstrate that a Barnes Grinder Pump with a 2" PVC discharge
pipe would be sufficient in the subject project's application. The pump basin has been sized as a 30-inch
diameter basin with a depth of 7'-6". For repair and maintenance, contact the following Barnes Pumps
authorized dealer:
Pacific Plumbing Supply Co.
7115 West Marginal Way SW
Seattle, WA 98106
206.762.5920
C 250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENGINEERING ph.425.778.8500 I f.425.778.5536
www.cgengineering.com
Flow Rate Calculations
Flow rate based on peak water demands of fixtures for
proposed house.
* Water Supply Fixture Units from 2015 Uniform
Plumbing Code, Table A-103.1 (attached)
From Chart A103.1(2) (attached),
demand =
43
0.100 cfs
t� �
Pump Calculations
By BJL
Date 3/11/2022
O
ENGINEERING
Flow Rate Calculations
Chkd
JPU
Date
250 4th Ave. South
Scale N.T.S.
Sheet No.
Suite 200
Job No.
Edmonds, WA 98020
Keck Residence
21125.20
Fixture
# of
Fixtures
WSFU*
Total
Units
Bath Tub
1
4.0
4
Clothes Washer
1
4.0
4
Dishwasher
1
1.5
1.5
Kitchen Sink
1
1.5
1.5
Laundry Sink
1
1.5
1.5
Washup Sink
6
2.0
12
Bar Sink
1.0
0
Mop Sink
1.5
0
Shower Head
3
2.0
6
Water Closet, 1.6 gpf
5
2.5
12.5
Total
43
TABLE d< 107,1
WATER SU€KY FI%TIj17E UNITS (WSFU) ANOBUNCUUM FA[TURE BRANCH PIPE 3=33
ARRIAMM&AI"R,ff9MVY#=ORFIXTURES'
�4# W w FIX741+E
��ve
PRWATP
Pk
� +d�rYS
HadMUb Or C4nn*d ' iQn
Y, i nch 84101tub Fill I Vah+t
?:
10.0
10.0
-
Didd
'A
IA
-
-
00(ks Walfli-ir
Ih
4_0
4A
-
Den W k; rki .vmrdor
'A
-
]JD
y
k}i+h>k'a'trer.&MC!Sut
'h
1.5
1.5
-
tkirkkit4roulftnIfLotwolefco*r
14
05
0.5
p,7S
}Drat Bibb
'h
2.5
2.5
-
Hose E ML tech add Kiarul7
'h
1 A
1A
-
Lxvakmy
'h
1.0
1_0
1.0
1.z;%-n lipmLlierr, 4Mq;hhgad}
1.0
1_0
Ntt)bi 6e I'k. rM4, rXkCa (ramai %= M
-
110
-
-
�Q11L 4
ChaKarFs�Icel
'h
-
-
Fliokaj €Im]Iarmwr Vahve wih ur wihimn faueel
I-
Ki6chm &Xwaic
A
1.5
1-5
-
Li
'A
1_5
)_S
-
!k"iCSOr MopUaLirk
13
3.0
-
ww r . "Kh Xq 9f au"M
Ih
4
2 0
-
$ti mw pw hesi
'h
2.0
?.0
-
4lr69. r.OGPFFttlahe"ierVahe
'
M
4A
$.O
4Jriaal, gotaoff Alan 1 JU GPF FIMaM r tkF Vatre
'.
3A
5A
(KID
Urm4Okuhtw&
IA
2.0
2.0
].0
V1'sthrMvAMM.6radarspray
M
Wa-crClknM 1.6GPFFl:�hmxlrrTsr&
a_5
].S
WAwCtizeL 1.6GPFFLutrw*m*FVOJVt
1Yat-crChnol,g btFdxanl-6GPFGrsrrilyT=k
'h
3.0
S_5
7.16
Vk'alarCer. Orin 1ACiPF Flu,hgrneoer %'altie
I
7.0
#0
I"
Rie Sl qEiu; I iah -' ereti
Ndxi
r Svc ofWhevddbnW*bFpr.arLWhmehdwdcold kwrbppcL
A(flra iffy, *paRearotar_ ry IAMcs no arptN&d an OFu Rabic Mall b<preftw W w br s rrvd by rrfok*;r Io- frtirrtm brF* a A"br rPow ii r aid At-
q&MUOfwF
s Thel;ale Axim wrtvdrxsrcpn-eniikoraadkedenrheeoW;%swb,.Id-r% iy.'Fkc o4iw*.Glvwk sad%wwowrh-
hres tuv* boll cold wwl hrc wakr rnar: Km -R hOl br FL,...! cd ta ex A be rakm as (hmc-qmlrn or rAe hdk d Ow vww of 0,,r i6ow,
e The aFppiy keixh part ,rep For,odi++lwl fkEwci at r1x roan,l (�D )pir K .ot
a For fiiiuror ar uWly mmwchom Irly Ia conrinuaur Sow domau h, dclQmhw iire re,}red Raw im pAona pw w > Ipm) ") and dd id
,MaklylaIfrtdermm4ieiim11.+aorwOwd+rnlSu..on,}t4mxpgE rMdKrhof.
# AmcibblyIP&txUw(xvTaW422.11)_
s Kc&4:A AmMiz-urar kudrnV *be rddilk" hwc brbkR a Io bc rrrd wbn'c -.=g wul builbr.,g d<srard wA For pIPcsvug wk-rc Mcrclhmovic bme
brbb u wppN d by a xgnco of waW dau itu bv4 pq s. T;h c rhmc b Wx N W cwTi. hme tab b"I be rrre+d -M ft pa r r o f : S fixRWc vest,•.
CHART 103.1{1)
E STI MATE CU RVE S FOR DEMAND LOAD
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■i:
■■■■■
Rp■
■■■■■
sommmorldrAm
i!J
10000.4,10
0 ,Y) 1001 1500 LI)O') 25Y_7
FIXTURE UNITS
FbrSl writs: t _�Ellbn Ix-rmmutr=0.06 Us
1O0
Z
6o
40
0
20
w
a 0
CHART A 1011(2)
ENLARGED SCALE DEMAND LOAD
:3'YJO
20 40 6O aU 10-0 120 140 16O 120 200 0 240
FIXTURE UNITS
Fcr SI units: t .8jA i per n7Lnute = 10.06 Us
Headloss Calculations
Total Headloss (HT) = Headloss due to friction (Hf) + Elevation Difference (Az)
HT = Hf + Az
Need to find velocity (v), Reynold's Number (Re), Relative Roughness (R), friction factor (f)
and equivalent length of pipe (Le).
Assumed Pipe Diameter, D (in.) = 2.0
D (ft.) = 0.17
Velocity, v = Q/A
A = IIr' = 0.023 ft 2
v = 4.35 ft/s
Reynold's Number, Re = Dv/v
v = Kinematic Viscosity of water (50° F) = 1.41E-OS ft2/s
Re = 52423
Relative Roughness, R = C/D
PVC = 5.00E-06 ft
R = 3.00E-OS
Friction factor, f = 0.037 (see attached Moody Diagram)
� Pump Calculations By BJL Date 3/11/2022
Chkd Date
ENGINEERING Headloss Calculations JPU
250 4th Ave. South Seale N.T.S. sheet No.
Edmonds, WA 98020 1 Keck Residence I
Job No. 21125.20
Headloss Calculations (continued)
Equivalent Length (Le) of flanged PVC fittings
Fitting
# of
Fittings
Le* (ft.)
Total Le
(ft.)
45° Elbow
1
1.7
1.7
Expansion Fitting
1
4.5
4.5
90° Elbow
2
3.1
6.2
Check Valve
1
19.0
19
Gate Valve
1
2.6
2.6
Total
34
* Le values from engineeringtoolbox.com
J'e,fittings = I 34.0 ft
Le,pipe exit = Kt,D/f Kt = Loss Coefficient, D = Diameter (ft), f = friction factor
Kt,
Le,pipe exit — 4.6 ft
(Le) = Le,fittings + Le,pipe exit
(Le) = 39.0 ft
Friction Headloss, Hf Hf= f L vZ L = 207.0 (length of pipe from
2Dg pump basin to main + Le)
Hf = 13 ft Elevation Change: 25 ft (Az)
HT = Hf + Az
HT = 38 ft
Pump Calculations By BJL Date 3/11/2022
C- Chkd Date
ENGINEERING Headloss Calculations JPU
250 4th Ave. South scale N.T.S. Sheet No.
Edmonds, WA 98020 Keck Residence I
Job No. 21125.20
Pump Elevation Specifications
Pump Elevations
Rim
230.0
Fin. Grade
229.90
Inlet
226.00
Alarm On
225.5
Pump On
224.5
Pump Off
223.00
Base
222.50
Storage Calculations
(1-2" below rim)
(6" below inlet)
(Y of effective storage between IE and Pump Off)
(6" above base for dead storage)
Effective storage occurs between the inlet IE and the "Pump Off" elevations.
Diameter of Pump Basin = 2.5 ft
Volume = Hr2h
Volume = 14.7 ft 3
Volume = 110.2 gallons of storage
Cycling Calculations
Pump Off = 223.00
Pump On = 224.5
Apump basin = 4.9 ft2
Discharge volume, VD = Von - Voff = 4.9 ft2 * (53.0 - 51.50)
VD = 7.4 ft3
VD = 55.1 gallons discharged
� Pump Calculations By BJL Date 3/11/2022
ENGINEERING Pump Elevations, Storage chka 7PU Date
250 4th Ave. South Calcs & Cycling Calcs Scale N.T.S. sheet No.
Edmonds, WA 98020 1 Keck Residence I
Job No. 21125.2O
Cycling Calculations (continued)
Qin = 43 gpm
Qont = 52 gpm (pump output for 38 ft of head)
Cycle Time, T = time for pump to clear basin and fill up again under peak flow rate.
Q = Qout - Qin = 9 gpm
Time to clear, Te = VD/Q = 6 minutes
Time to fill, Tf = VD/Qin = 1.3 minutes
T = Te + Tf = 7.3 minutes per cycle
Cycles per hour = 8.2 cycles per hour (during peak flow)
Buoyancy Calculations
FB = V, * pW; V, = Volume of Sump; pw = Density of Water; FB = Buoyant Force
s — pump basin pump basin
Vs = 36.8 ft 3
FB = 2297 lbs
Hpump basin = 7.S ft p„ . (pcfl= 62.4
To prevent flotation, we need Fe = FB; Need to find volume of concrete required to resist
flotation.
Fe = peVe - pwVe ----> Fe = Ve*(pe — pW) ----> Ve = Fe / (peps) Fe = Concrete Force
Fe = 2297 lbs
p e = 145 pcf
VC = 27.8 ft3 of concrete required to resist flotation
Vc,20%Fos = 33.4 ft3
See attached sketch of Anti -flotation device for reference.
Ve = IIr2H + (2ft)*(Aouter - Ainner)
H= T 9-01 ft
Pump Calculations
0
ENGINEERING Cycling and Buoy
250 4th Ave. South Calculations
Edmonds, WA 98020 1 Keck Residence
Aouter (ft 2)= 12.57
By
No.
`inner (ft 2)= 4.91
BJL Date
3/11/2022
JPU Date
N.T.S. Sheet No.
21125.20
BARNES @
Series SGVF & SGVH
Recessed Vortex
www.cranepumps.com
Specifications:
DISCHARGE ...................................
LIQUID TEMPERATURE ................
VOLUTE ............................................
MOTOR HOUSING ............................
SEAL PLATE ....................................
IMPELLER: Design ......................
Material .....................
SHREDDING RING ...........................
CUTTER............................................
SHAFT..............................................
SQUARE RINGS ...............................
HARDWARE ......................................
PAINT................................................
SEAL: Design .......................
Material ......................
CORD ENTRY ...................................
CORD.................................................
UPPER BEARING:
Design .......................
Load..........................
INTERMEDIATE BEARING:
Design .......................
Load..........................
LOWER BEARING:
Design .......................
Load...........................
MOTOR: Design .......................
Insulation ................
SINGLE PHASE .................................
THREE PHASE ..................................
OPTIONAL EQUIPMENT ...................
1'/4" NPT, Vertical, Bolt -on Flange
160°F (71°C)Intermittent
Cast Iron ASTM A-48, Class 30.
Cast Iron ASTM A-48, Class 30.
Cast Iron ASTM A-48, Class 30.
12 Vane,Vortex, With Pump Out Vanes
On Back Side. Dynamically Balanced,
ISO G6.3.
Cast Iron
Hardened 440C Stainless Steel
Rockwell® C-55.
Hardened 440CStainless Steel,
Rockwell® C-55.
416 Stainless Steel
Buna-N
300 Series Stainless Steel
Air Dry Enamel.
Tandem Mechanical, Oil Filled Reservoir.
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware -300 Series Stainless
30 ft. (9.1 m) Std. Cord. Custom Molded
Quick Connect, for Sealing and Strain
Relief
CSA/UL Approved 12/4 Type SOW.
Single Row, Ball, Oil Lubricated
Radial
Single Row, Ball, Oil Lubricated
Radial & Thrust
Sleeve, Oil Lubrication:
Radial
NEMA L-Single Phase, (SGVF2022L,
SGVH2O22L, SGVF2002L or SGVH2O02L,
includes overload protection in the
motor). NEMA B-Three Phase Torque
Curve. Oil -Filled, Squirrel Cage Induction
Class B.
Capacitor Start/Capacitor Run. Includes
overload protection in the motor. Requires
Barnes® Starter or Control Panel which
Includes Capacitors, or Capacitor pack.
Dual Voltage 240/480; Requires Overload
Protection to be Included in control panel.
Seal Material, Impeller Trims, Cord Length.
Moisture Sensors, Moveable Fitting, Leg Kit
P/N:108339.
RECOMMENDED:
Accessories ..................
Break Away Fitting (BAF)
Check Valve
Control Panel
Seal Kit PN ..................113299
Service Kit PN..............115946
SP°
C US SWPQ
LR16567
Submersible Grinder Pumps
/3
CENTRIFUGAL GRIND
Series: SGVF & SGVH
2HP, 3450RPM, 60Hz
High -Flow and High Head
Sample Specifications: Section 3 Page 8.
DESCRIPTION:
THE GRINDER PUMP IS DESIGNED TO
REDUCE DOMESTIC, COMMERCIAL,
INSTITUTIONAL AND LIGHT INDUSTRIAL
SEWAGE TO A FINELY GROUND SLURRY.
QWARNING:
1 CANCER AND REPRODUCTIVE HARM -
WWW.P65WARNINGS.CA.GOV
CRANE
E.
A Crane Co. Company
PUMPS & SYSTEMS
USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598
SECTION 3B
PAGE 1
DATE 12/18
Series SGVF & SGVH
Recessed Vortex
BARNES"
Submersible Grinder Pumps
www.cranepumps.com
inches
(mm)
11.30
(287)
22.30 (567)
5.55
I � I
WITH
( 141)
f 1.13 (29)
�w J
OPTIONAL
LEGS
19.40
I
(493)
OPTIONAL
j •
4.53
(115)
9.16
1.25" NPT FEMALE
*
(233)
3.88 (99)
j
OPTIONAL
LEGS
2.70 (74)E`E
I
I
MODEL NO
PART NO
HP
VOLT
PH/Hz
RPM
NEMA
FULL
LOCKED
CORD
CORD
CORD O.D.
(Nora)
START
LOAD
ROTOR
SIZE
TYPE
± .02 (.5)
CODE
AMPS
AMPS
in (mm)
HIGH -FLOW
SGVF2002L*
110614
2
200
1 / 60
3450
F
17.0
53.0
12/4
SOW
.67(17)
SGVF2022L
110609
2
240
1 / 60
3450
H
15.0
53.8
12/4
SOW.
.67(17)
SGVF2062L
110610
2
200
3 / 60
3450
J
11.0
42.0
12/4
SOW
.67(17)
SGVF2032L
110611
2
240
3 / 60
3450
J
9.0
36.0
12/4
SOW
.67(17)
SGVF2042L
110612
2
480
3 / 60
3450
J
4.0
18.0
12/4
SOW
67 (17)
SGVF2052L
110613
2
600
3 / 60
3450
J
3.2
14.4
12/4
SOW
.67(17)
HIGH -HEAD
SGVH2O02L'
110620
2
200
1 / 60
3450
F
17.0
53.0
12/4
SOW
.67(17)
SGVH2O22L
110615
2
240
1 / 60
3450
H
15.0
53.8
12/4
SOW
.67(17)
SGVH2O62L
110616
2
200
3 / 60
3450
J
11.0
42.0
12/4
SOW
.67(17)
SGVH2O32L
110617
2
240
3 / 60
3450
J
9.0
36.0
12/4
SOW
.67(17)
SGVH2O42L
110618
2
480
3 / 60
3450
J
4.0
18.0
12/4
SOW
.67(17)
SGVH2O52L
110619
2
600
3 / 60
3450
J
3.2
14.4
12/4
SOW
.67(17)
Optional - Temperature sensor cord for all
models is 14/3 SOW, 0.55 (14mm) ± .02 (.51 mm) O.D.
(Not used on SGVF2022L, SGVH2O22L, SGVF2002L
or SGVH2O02L).
Optional - Moisture and Temperature sensor cord for all models is 18/5 SOW, 0.49 (12.4mm) ± .02
(.51 mm) O.D., replaces
Temperature sensor cord.
(') This pump is NOT CSA listed
IMPORTANT!
1.) MODELS SGVF2002LAND SGFH2002LARE NOT CSA LISTED
2. ) PUMP MAY BE OPERATED "DRY" FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
3.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES
PROVIDED FOR VISUAL
ENJOYMENT MUST BE
INSTALLED IN
ACCORDANCE
WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY
HAVING JURISDICTION.
THIS PUMP IS NOT INTENDED FOR USE IN
SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS ACOMMON OCCURRENCE.
TION 3BCRAN
E 2E
r
E PUMPS & SYSTEMS
12/18
a
A Crane Co. Company USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598
BARNES @
Series SGVF
Performance Curve
www.cranepumps.com
2HP, 345ORPM, 6OHz, High -Flow
Submersible Grinder Pumps
Testing is performed with water, specific gravity 1.0 @ 680 F @ (20'C), other fluids may vary perfor-
mance
CRANE
E.
A Crane Co. Company
PUMPS & SYSTEMS
USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598
SECTION 3B
PAGE 3
DATE 7/09
w
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■STANDARD IMPELLER SIZES
Pump HIP Impeller Dia.
2.0 5.63 (143)
•ENNE
NOON■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
' NOON■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
NOON■\��\■■■■■■■■■■\��!�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
OR_■■■MEN ■\\■■■■■■■■■■■■\IN= NONE
s■\�■■■■■■■■■■■■\i��\�■■■■■NOON■\����■■■■■■■■■■■■■■■■■■■■■
No 11 inn\mi� WOMEN ■■■■■■■■■\wiz!\■■■■■■■■■■\�z\■■■■■■■■■■■■■■■■■■■
NOON■\� ���■■■■■■■■■■\��_��■■■■■■■■■\���■■■■■■■■■■\�\■■■■■■■■■■■■■■■■■
No ■■■■■■ ■■■■■■■■■■■\la-Z"■■■■■■■■\z!\m■■■■■\N■■■■■■■■■■■■■■
ZW■■■■■■■■■■\����\■■■■■■■■■\���\NOON■■■\��\NOON\\■■■■■■■■■■■■■�
■■\� ��■■■■■■■■■■■■■■■■■\s��\■■■■■■■■\��\NOON■■■\�\■■■\\■■■■■■■■■■■■■
NOON■■\��!����■■■■■■■■■■■■■■\���\q■■■■■■\��■■■■■■■\O\■■\\■■■■■■■■■■■
■' 11]■■\������■�■■■■■■■■■■o■\���\■■■■■\��\NOON■■\\■■►\■■■■■■■■■■■
■\w`�■■■■■■■■■■■�s�!N■�■■■■■■■■■\���■\NOON\�\NOON■\\■\\■■■■■■■■■■■
NOON\��\■■■■■■■■■■■■■■■■■�� !�■■■■■■■■■■\\��\■■■\�\NOON\`■■�\■■■■■■■■■■
■■■■■■■\NEZ--M:■■■■■■■■■■■■■■N■\mwZRI\■■■■■■■■■■�74\■\ ■,\ ■■\■■■■11■■■■■■■■■■'
■■■■\\im,'n`WW■■■■■■■■■■■■■■\C..!\M■■■■■■■■\'\■ OWES! ■L1■1'■■■■■■■■■■■
■■■■\��!\■■■■■■■■■■■■■■■■■■■E\s!�■■■■■■■■\��\NOON■\\■\\■�■�■■■■■■■■■■
■■■■■■■■\aw=nNi■■■■■■■■■■■■■■■■■■■\�� \■■■NOON\�\■■■■\\■►1■11■1■■■■■■■■■■
■ ■■■■■�� ��■■■■■■■■■■■■■■■■■■■\�TIMEMMEN�T-■■■\1■\\IINI■■■■■■■■■■
1 1 1 ■ MOON■■ ■i■■\ �� !1 NE■■■ ■■■■■ ■■■■■ ■\\Z\ 00000 NO\■\\ ■111'■I 100000 ■■■■■
■A.. _ ■■ ■■■■■ ■■■■■ ■■■■■ \i !w ME■■■ ■■■■■ ■■■■\ i�.!4000 ■\\■L1 011■ 21100000 ■■■■a
NOON■■\�� !��E�■■■■■■■■■■■■�■■\� !\�■■■■■NOON■■\�\■■►�■\'■■■�11■■■■■■■■■
NOON■ NOON■ NOON■ NOON\ �� �� \�■■■ NOON■ ■■■\� ��\■■ NOON■ ■►\\`■ 11■i II 11 I ■■■■■ ■■■■
■■ NOON■ NOON■ ■■�■■ \a�� ■�■■■ NOON■■\�� \NOON ■■\\,\ \\11111 NOON■ NOON ZT ■ ■■■■■ BAR 1111 ■■■■■ ■■■■■
■■■\e�.=!ONEM■■■■■■■■■■■■■■■■■■■■■■■■\aim■\■■■■■■\b\■■■\.\.\\1■ft1■■■■■■■■■'
■��!�■■■■■■■■■■■■■■■■■■■■■■■■■\M��■■■■■■\�\■■\`\`\NCI■■■■■■■■■
1 • ■ ■■■■■ ��� 0-i■■■ ■■■■■ ■■■■■ ■■■■■ ■■■N0 \■■■■ ■\"■■ 111111 ■■■■■ ■■■■■
mAz a1■■■ NOON■ NOON■ ■\ate W■■■■ NOON■ NOON■ NOON■ \Z\■■ ■■■►`\ VOL 1111 NOON■ NOON
NO�ON■\��� ��■■■■■■■■■■■■■■■\��_!■■■■■■■■■■■■■■■■\��■■■■►`■�\\'llll■■■■■■■■■�
�i�SiliiJllB ON��� ��Ai iNNEN 0�000 MU��� \•i�M 0���0 MENEM \MMM\\ \� 111 00000 MENEM
■\��w■■■■■NOON■NOON■■■■■\ER M■■■■■■■■■■■\R\■■NOON■■OC■\`1\`1IINEON■■■■■■
■ ���■■■_■■■■■■■■■■■■■■■\s!\■■■■■■■■■\�!\NOON■■\�■■�\\'I■■■■■■■■■■
a 11 .■■\one =--NNE■■■■■■■■■■■■■\ft=!'\E■■■■■■■\74\■■■■■\\■\\1■■■■■■■■■■
0000000000
NOON■■\� ����■■■■■■■■■■■■■■■\��\■■■■■■■■■■\�\NOON■►`\■■■\`\ ■■■■■■■■■■
■■■■■■■■■■■■\��� !�■■■■■■■■■■■■■\\���■■■NOON■■\��■■■■\`\■■\�1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■�i� !�■■■■■■■■■■■\� !\NOON■■■\��■■■►`■■■■1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■\��� �■■■■■■■■■\��\NOON■■■►`\■■►�■■■1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\���■■■■■NOON\��■■■■■■\\■\i■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\■NOON■■■\�\NOON\\■■■■1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\NOON■■■\�\■■■\�■■■1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\NOON■■\:■■■■■■■1■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\�!\NOON■►`\■■■■■i■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■NOON■■\�\NOON\`�■■■■■■■■■■■■■■■
0
\OISTRIO, 980 080663)
(AF N0. 9806080663)
III I I I
I �I' I III I
I
I ICI
NO
O25O
OPE
A PORTION SE 1 /4 OF THE SE 1 /
ACCESS & UIILITY EASOAENE-
GARAGE (AT NO. 201603295002) L
\ \/ RX =843
\ Q EOUND EBAR
AND
o HOUSE RIDGE "LDC 48761"
SEWER PUMP STATION \EL= 6'
RIM: 228.5
I 3 4 E (4" S): 226.0
IE (2" E): 225.0
4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M.
\ I I
I
NT40'31'W
36
WATER AND SEWER PLAN
1 SCALE: 1" = 20'
WATER AND SEWER PLAN NOTES: 20 0 10 20 40
1. PLUMBING CONSULTANT TO VERIFY METER & SERVICE SIZE. SIZING TO BE CONFIRMED ONCE PLUMBING
PERMIT IS ISSUED AND REVIEWED.
2. PLUMBING CONSULTANT TO VERIFY SIZE OF EXISTING SEWER STUB IS ADEQUATE FOR PROPOSED BUILDING.
3. A MINIMUM OF T SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC)
AND SEWER, WATER, AND STORM.
4. A MINIMUM OF 5' OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN WATER AND STORM LINES.
PUMP STATION CONTROL PANEL W/ ALARM AND LIGHT
IE (2" FORCE MAIN): 226.50
IE (ELECTRICAL CONDUIT): 228.0 EXISTING GRADE ELECTRICAL CONDUIT
260 - - - - - - - - PROPOSED GRADE - - - - - - - - - - - 260
255 A
255
250 250
245 __.-. 245
240 .. ... 240
235 235
230 - I' 230
225 225
220 220
10 UP 8" DIP CASING SS STUB IE: 250.29
2" IPS POLY HIGH-MOL PIPE
A
FORCE MAIN AND ELECTRICAL CONDUIT PROFILE
SCALE: 1" = 20'
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE -
BY., _
CITY ENGINEERING DIVISION
= cm I
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
O3/II/22
w
0
DESIGN: BJL
DRAWN:
ATD
CHECK:
JPU
JOB NO:
21125.20
DATE:
12/03/21
N
W J
3 0o
W �
LJJ 00
N w
U Q
LJI p 3:
Z C)
Z
Q Z
Q
0
N Z
w Z
~ Q
U I�
Y La>
Q
> 0-
SHEET
C 4.1