Loading...
APPROVED ENG-Sewer Pump Calculations-BLD2021-0985C � ENGINEERING 250 4' Ave S Ste 200 Edmonds, WA 98020 Phone: (425)778-8500 Fax: (425) 778-5536 civil & structural engineering & planning RESUB Mar 22 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Sewer Pump Calculations Keck Residence 15722 72nd Ave W Edmonds, WA 98026 0311112022 CIS Project No.: 21125.20 ENGINEERING DIVISION APPROVED AS NOTED L�//� 5/06/2022 CALCULATIONS REVIEWED AND APPROVED BY: MIKE DE LILLA, P.E. CITY UTILTIIES ENGINEER Keck Residence - CG #21125.20 March 11, 2022 Pump Calculations Page 1 This package contains: - Flow Rate Calculations - Headloss Calculations - Pump Elevation Specifications - Storage Calculations - Cycling Calculations - Buoyancy Calculations - Pump Literature/Specifications - 11x17 Water and Sewer Plan Sheet The calculations contained herein demonstrate that a Barnes Grinder Pump with a 2" PVC discharge pipe would be sufficient in the subject project's application. The pump basin has been sized as a 30-inch diameter basin with a depth of 7'-6". For repair and maintenance, contact the following Barnes Pumps authorized dealer: Pacific Plumbing Supply Co. 7115 West Marginal Way SW Seattle, WA 98106 206.762.5920 C 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ENGINEERING ph.425.778.8500 I f.425.778.5536 www.cgengineering.com Flow Rate Calculations Flow rate based on peak water demands of fixtures for proposed house. * Water Supply Fixture Units from 2015 Uniform Plumbing Code, Table A-103.1 (attached) From Chart A103.1(2) (attached), demand = 43 0.100 cfs t� � Pump Calculations By BJL Date 3/11/2022 O ENGINEERING Flow Rate Calculations Chkd JPU Date 250 4th Ave. South Scale N.T.S. Sheet No. Suite 200 Job No. Edmonds, WA 98020 Keck Residence 21125.20 Fixture # of Fixtures WSFU* Total Units Bath Tub 1 4.0 4 Clothes Washer 1 4.0 4 Dishwasher 1 1.5 1.5 Kitchen Sink 1 1.5 1.5 Laundry Sink 1 1.5 1.5 Washup Sink 6 2.0 12 Bar Sink 1.0 0 Mop Sink 1.5 0 Shower Head 3 2.0 6 Water Closet, 1.6 gpf 5 2.5 12.5 Total 43 TABLE d< 107,1 WATER SU€KY FI%TIj17E UNITS (WSFU) ANOBUNCUUM FA[TURE BRANCH PIPE 3=33 ARRIAMM&AI"R,ff9MVY#=ORFIXTURES' �4# W w FIX741+E ��ve PRWATP Pk � +d�rYS HadMUb Or C4nn*d ' iQn Y, i nch 84101tub Fill I Vah+t ?: 10.0 10.0 - Didd 'A IA - - 00(ks Walfli-ir Ih 4_0 4A - Den W k; rki .vmrdor 'A - ]JD y k}i+h>k'a'trer.&MC!Sut 'h 1.5 1.5 - tkirkkit4roulftnIfLotwolefco*r 14 05 0.5 p,7S }Drat Bibb 'h 2.5 2.5 - Hose E ML tech add Kiarul7 'h 1 A 1A - Lxvakmy 'h 1.0 1_0 1.0 1.z;%-n lipmLlierr, 4Mq;hhgad} 1.0 1_0 Ntt)bi 6e I'k. rM4, rXkCa (ramai %= M - 110 - - �Q11L 4 ChaKarFs�Icel 'h - - Fliokaj €Im]Iarmwr Vahve wih ur wihimn faueel I- Ki6chm &Xwaic A 1.5 1-5 - Li 'A 1_5 )_S - !k"iCSOr MopUaLirk 13 3.0 - ww r . "Kh Xq 9f au"M Ih 4 2 0 - $ti mw pw hesi 'h 2.0 ?.0 - 4lr69. r.OGPFFttlahe"ierVahe ' M 4A $.O 4Jriaal, gotaoff Alan 1 JU GPF FIMaM r tkF Vatre '. 3A 5A (KID Urm4Okuhtw& IA 2.0 2.0 ].0 V1'sthrMvAMM.6radarspray M Wa-crClknM 1.6GPFFl:�hmxlrrTsr& a_5 ].S WAwCtizeL 1.6GPFFLutrw*m*FVOJVt 1Yat-crChnol,g btFdxanl-6GPFGrsrrilyT=k 'h 3.0 S_5 7.16 Vk'alarCer. Orin 1ACiPF Flu,hgrneoer %'altie I 7.0 #0 I" Rie Sl qEiu; I iah -' ereti Ndxi r Svc ofWhevddbnW*bFpr.arLWhmehdwdcold kwrbppcL A(flra iffy, *paRearotar_ ry IAMcs no arptN&d an OFu Rabic Mall b<preftw W w br s rrvd by rrfok*;r Io- frtirrtm brF* a A"br rPow ii r aid At- q&MUOfwF s Thel;ale Axim wrtvdrxsrcpn-eniikoraadkedenrheeoW;%swb,.Id-r% iy.'Fkc o4iw*.Glvwk sad%wwowrh- hres tuv* boll cold wwl hrc wakr rnar: Km -R hOl br FL,...! cd ta ex A be rakm as (hmc-qmlrn or rAe hdk d Ow vww of 0,,r i6ow, e The aFppiy keixh part ,rep For,odi++lwl fkEwci at r1x roan,l (�D )pir K .ot a For fiiiuror ar uWly mmwchom Irly Ia conrinuaur Sow domau h, dclQmhw iire re,}red Raw im pAona pw w > Ipm) ") and dd id ,MaklylaIfrtdermm4ieiim11.+aorwOwd+rnlSu..on,}t4mxpgE rMdKrhof. # AmcibblyIP&txUw(xvTaW422.11)_ s Kc&4:A AmMiz-urar kudrnV *be rddilk" hwc brbkR a Io bc rrrd wbn'c -.=g wul builbr.,g d<srard wA For pIPcsvug wk-rc Mcrclhmovic bme brbb u wppN d by a xgnco of waW dau itu bv4 pq s. T;h c rhmc b Wx N W cwTi. hme tab b"I be rrre+d -M ft pa r r o f : S fixRWc vest,•. CHART 103.1{1) E STI MATE CU RVE S FOR DEMAND LOAD ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■i: ■■■■■ Rp■ ■■■■■ sommmorldrAm i!J 10000.4,10 0 ,Y) 1001 1500 LI)O') 25Y_7 FIXTURE UNITS FbrSl writs: t _�Ellbn Ix-rmmutr=0.06 Us 1O0 Z 6o 40 0 20 w a 0 CHART A 1011(2) ENLARGED SCALE DEMAND LOAD :3'YJO 20 40 6O aU 10-0 120 140 16O 120 200 0 240 FIXTURE UNITS Fcr SI units: t .8jA i per n7Lnute = 10.06 Us Headloss Calculations Total Headloss (HT) = Headloss due to friction (Hf) + Elevation Difference (Az) HT = Hf + Az Need to find velocity (v), Reynold's Number (Re), Relative Roughness (R), friction factor (f) and equivalent length of pipe (Le). Assumed Pipe Diameter, D (in.) = 2.0 D (ft.) = 0.17 Velocity, v = Q/A A = IIr' = 0.023 ft 2 v = 4.35 ft/s Reynold's Number, Re = Dv/v v = Kinematic Viscosity of water (50° F) = 1.41E-OS ft2/s Re = 52423 Relative Roughness, R = C/D PVC = 5.00E-06 ft R = 3.00E-OS Friction factor, f = 0.037 (see attached Moody Diagram) � Pump Calculations By BJL Date 3/11/2022 Chkd Date ENGINEERING Headloss Calculations JPU 250 4th Ave. South Seale N.T.S. sheet No. Edmonds, WA 98020 1 Keck Residence I Job No. 21125.20 Headloss Calculations (continued) Equivalent Length (Le) of flanged PVC fittings Fitting # of Fittings Le* (ft.) Total Le (ft.) 45° Elbow 1 1.7 1.7 Expansion Fitting 1 4.5 4.5 90° Elbow 2 3.1 6.2 Check Valve 1 19.0 19 Gate Valve 1 2.6 2.6 Total 34 * Le values from engineeringtoolbox.com J'e,fittings = I 34.0 ft Le,pipe exit = Kt,D/f Kt = Loss Coefficient, D = Diameter (ft), f = friction factor Kt, Le,pipe exit — 4.6 ft (Le) = Le,fittings + Le,pipe exit (Le) = 39.0 ft Friction Headloss, Hf Hf= f L vZ L = 207.0 (length of pipe from 2Dg pump basin to main + Le) Hf = 13 ft Elevation Change: 25 ft (Az) HT = Hf + Az HT = 38 ft Pump Calculations By BJL Date 3/11/2022 C- Chkd Date ENGINEERING Headloss Calculations JPU 250 4th Ave. South scale N.T.S. Sheet No. Edmonds, WA 98020 Keck Residence I Job No. 21125.20 Pump Elevation Specifications Pump Elevations Rim 230.0 Fin. Grade 229.90 Inlet 226.00 Alarm On 225.5 Pump On 224.5 Pump Off 223.00 Base 222.50 Storage Calculations (1-2" below rim) (6" below inlet) (Y of effective storage between IE and Pump Off) (6" above base for dead storage) Effective storage occurs between the inlet IE and the "Pump Off" elevations. Diameter of Pump Basin = 2.5 ft Volume = Hr2h Volume = 14.7 ft 3 Volume = 110.2 gallons of storage Cycling Calculations Pump Off = 223.00 Pump On = 224.5 Apump basin = 4.9 ft2 Discharge volume, VD = Von - Voff = 4.9 ft2 * (53.0 - 51.50) VD = 7.4 ft3 VD = 55.1 gallons discharged � Pump Calculations By BJL Date 3/11/2022 ENGINEERING Pump Elevations, Storage chka 7PU Date 250 4th Ave. South Calcs & Cycling Calcs Scale N.T.S. sheet No. Edmonds, WA 98020 1 Keck Residence I Job No. 21125.2O Cycling Calculations (continued) Qin = 43 gpm Qont = 52 gpm (pump output for 38 ft of head) Cycle Time, T = time for pump to clear basin and fill up again under peak flow rate. Q = Qout - Qin = 9 gpm Time to clear, Te = VD/Q = 6 minutes Time to fill, Tf = VD/Qin = 1.3 minutes T = Te + Tf = 7.3 minutes per cycle Cycles per hour = 8.2 cycles per hour (during peak flow) Buoyancy Calculations FB = V, * pW; V, = Volume of Sump; pw = Density of Water; FB = Buoyant Force s — pump basin pump basin Vs = 36.8 ft 3 FB = 2297 lbs Hpump basin = 7.S ft p„ . (pcfl= 62.4 To prevent flotation, we need Fe = FB; Need to find volume of concrete required to resist flotation. Fe = peVe - pwVe ----> Fe = Ve*(pe — pW) ----> Ve = Fe / (peps) Fe = Concrete Force Fe = 2297 lbs p e = 145 pcf VC = 27.8 ft3 of concrete required to resist flotation Vc,20%Fos = 33.4 ft3 See attached sketch of Anti -flotation device for reference. Ve = IIr2H + (2ft)*(Aouter - Ainner) H= T 9-01 ft Pump Calculations 0 ENGINEERING Cycling and Buoy 250 4th Ave. South Calculations Edmonds, WA 98020 1 Keck Residence Aouter (ft 2)= 12.57 By No. `inner (ft 2)= 4.91 BJL Date 3/11/2022 JPU Date N.T.S. Sheet No. 21125.20 BARNES @ Series SGVF & SGVH Recessed Vortex www.cranepumps.com Specifications: DISCHARGE ................................... LIQUID TEMPERATURE ................ VOLUTE ............................................ MOTOR HOUSING ............................ SEAL PLATE .................................... IMPELLER: Design ...................... Material ..................... SHREDDING RING ........................... CUTTER............................................ SHAFT.............................................. SQUARE RINGS ............................... HARDWARE ...................................... PAINT................................................ SEAL: Design ....................... Material ...................... CORD ENTRY ................................... CORD................................................. UPPER BEARING: Design ....................... Load.......................... INTERMEDIATE BEARING: Design ....................... Load.......................... LOWER BEARING: Design ....................... Load........................... MOTOR: Design ....................... Insulation ................ SINGLE PHASE ................................. THREE PHASE .................................. OPTIONAL EQUIPMENT ................... 1'/4" NPT, Vertical, Bolt -on Flange 160°F (71°C)Intermittent Cast Iron ASTM A-48, Class 30. Cast Iron ASTM A-48, Class 30. Cast Iron ASTM A-48, Class 30. 12 Vane,Vortex, With Pump Out Vanes On Back Side. Dynamically Balanced, ISO G6.3. Cast Iron Hardened 440C Stainless Steel Rockwell® C-55. Hardened 440CStainless Steel, Rockwell® C-55. 416 Stainless Steel Buna-N 300 Series Stainless Steel Air Dry Enamel. Tandem Mechanical, Oil Filled Reservoir. Rotating Faces - Carbon Stationary Faces - Ceramic Elastomer - Buna-N Hardware -300 Series Stainless 30 ft. (9.1 m) Std. Cord. Custom Molded Quick Connect, for Sealing and Strain Relief CSA/UL Approved 12/4 Type SOW. Single Row, Ball, Oil Lubricated Radial Single Row, Ball, Oil Lubricated Radial & Thrust Sleeve, Oil Lubrication: Radial NEMA L-Single Phase, (SGVF2022L, SGVH2O22L, SGVF2002L or SGVH2O02L, includes overload protection in the motor). NEMA B-Three Phase Torque Curve. Oil -Filled, Squirrel Cage Induction Class B. Capacitor Start/Capacitor Run. Includes overload protection in the motor. Requires Barnes® Starter or Control Panel which Includes Capacitors, or Capacitor pack. Dual Voltage 240/480; Requires Overload Protection to be Included in control panel. Seal Material, Impeller Trims, Cord Length. Moisture Sensors, Moveable Fitting, Leg Kit P/N:108339. RECOMMENDED: Accessories .................. Break Away Fitting (BAF) Check Valve Control Panel Seal Kit PN ..................113299 Service Kit PN..............115946 SP° C US SWPQ LR16567 Submersible Grinder Pumps /3 CENTRIFUGAL GRIND Series: SGVF & SGVH 2HP, 3450RPM, 60Hz High -Flow and High Head Sample Specifications: Section 3 Page 8. DESCRIPTION: THE GRINDER PUMP IS DESIGNED TO REDUCE DOMESTIC, COMMERCIAL, INSTITUTIONAL AND LIGHT INDUSTRIAL SEWAGE TO A FINELY GROUND SLURRY. QWARNING: 1 CANCER AND REPRODUCTIVE HARM - WWW.P65WARNINGS.CA.GOV CRANE E. A Crane Co. Company PUMPS & SYSTEMS USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 SECTION 3B PAGE 1 DATE 12/18 Series SGVF & SGVH Recessed Vortex BARNES" Submersible Grinder Pumps www.cranepumps.com inches (mm) 11.30 (287) 22.30 (567) 5.55 I � I WITH ( 141) f 1.13 (29) �w J OPTIONAL LEGS 19.40 I (493) OPTIONAL j • 4.53 (115) 9.16 1.25" NPT FEMALE * (233) 3.88 (99) j OPTIONAL LEGS 2.70 (74)E`E I I MODEL NO PART NO HP VOLT PH/Hz RPM NEMA FULL LOCKED CORD CORD CORD O.D. (Nora) START LOAD ROTOR SIZE TYPE ± .02 (.5) CODE AMPS AMPS in (mm) HIGH -FLOW SGVF2002L* 110614 2 200 1 / 60 3450 F 17.0 53.0 12/4 SOW .67(17) SGVF2022L 110609 2 240 1 / 60 3450 H 15.0 53.8 12/4 SOW. .67(17) SGVF2062L 110610 2 200 3 / 60 3450 J 11.0 42.0 12/4 SOW .67(17) SGVF2032L 110611 2 240 3 / 60 3450 J 9.0 36.0 12/4 SOW .67(17) SGVF2042L 110612 2 480 3 / 60 3450 J 4.0 18.0 12/4 SOW 67 (17) SGVF2052L 110613 2 600 3 / 60 3450 J 3.2 14.4 12/4 SOW .67(17) HIGH -HEAD SGVH2O02L' 110620 2 200 1 / 60 3450 F 17.0 53.0 12/4 SOW .67(17) SGVH2O22L 110615 2 240 1 / 60 3450 H 15.0 53.8 12/4 SOW .67(17) SGVH2O62L 110616 2 200 3 / 60 3450 J 11.0 42.0 12/4 SOW .67(17) SGVH2O32L 110617 2 240 3 / 60 3450 J 9.0 36.0 12/4 SOW .67(17) SGVH2O42L 110618 2 480 3 / 60 3450 J 4.0 18.0 12/4 SOW .67(17) SGVH2O52L 110619 2 600 3 / 60 3450 J 3.2 14.4 12/4 SOW .67(17) Optional - Temperature sensor cord for all models is 14/3 SOW, 0.55 (14mm) ± .02 (.51 mm) O.D. (Not used on SGVF2022L, SGVH2O22L, SGVF2002L or SGVH2O02L). Optional - Moisture and Temperature sensor cord for all models is 18/5 SOW, 0.49 (12.4mm) ± .02 (.51 mm) O.D., replaces Temperature sensor cord. (') This pump is NOT CSA listed IMPORTANT! 1.) MODELS SGVF2002LAND SGFH2002LARE NOT CSA LISTED 2. ) PUMP MAY BE OPERATED "DRY" FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 3.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS ACOMMON OCCURRENCE. TION 3BCRAN E 2E r E PUMPS & SYSTEMS 12/18 a A Crane Co. Company USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 BARNES @ Series SGVF Performance Curve www.cranepumps.com 2HP, 345ORPM, 6OHz, High -Flow Submersible Grinder Pumps Testing is performed with water, specific gravity 1.0 @ 680 F @ (20'C), other fluids may vary perfor- mance CRANE E. A Crane Co. Company PUMPS & SYSTEMS USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 SECTION 3B PAGE 3 DATE 7/09 w ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■STANDARD IMPELLER SIZES Pump HIP Impeller Dia. 2.0 5.63 (143) •ENNE NOON■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ' NOON■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ NOON■\��\■■■■■■■■■■\��!�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ OR_■■■MEN ■\\■■■■■■■■■■■■\IN= NONE s■\�■■■■■■■■■■■■\i��\�■■■■■NOON■\����■■■■■■■■■■■■■■■■■■■■■ No 11 inn\mi� WOMEN ■■■■■■■■■\wiz!\■■■■■■■■■■\�z\■■■■■■■■■■■■■■■■■■■ NOON■\� ���■■■■■■■■■■\��_��■■■■■■■■■\���■■■■■■■■■■\�\■■■■■■■■■■■■■■■■■ No ■■■■■■ ■■■■■■■■■■■\la-Z"■■■■■■■■\z!\m■■■■■\N■■■■■■■■■■■■■■ ZW■■■■■■■■■■\����\■■■■■■■■■\���\NOON■■■\��\NOON\\■■■■■■■■■■■■■� ■■\� ��■■■■■■■■■■■■■■■■■\s��\■■■■■■■■\��\NOON■■■\�\■■■\\■■■■■■■■■■■■■ NOON■■\��!����■■■■■■■■■■■■■■\���\q■■■■■■\��■■■■■■■\O\■■\\■■■■■■■■■■■ ■' 11]■■\������■�■■■■■■■■■■o■\���\■■■■■\��\NOON■■\\■■►\■■■■■■■■■■■ ■\w`�■■■■■■■■■■■�s�!N■�■■■■■■■■■\���■\NOON\�\NOON■\\■\\■■■■■■■■■■■ NOON\��\■■■■■■■■■■■■■■■■■�� !�■■■■■■■■■■\\��\■■■\�\NOON\`■■�\■■■■■■■■■■ ■■■■■■■\NEZ--M:■■■■■■■■■■■■■■N■\mwZRI\■■■■■■■■■■�74\■\ ■,\ ■■\■■■■11■■■■■■■■■■' ■■■■\\im,'n`WW■■■■■■■■■■■■■■\C..!\M■■■■■■■■\'\■ OWES! ■L1■1'■■■■■■■■■■■ ■■■■\��!\■■■■■■■■■■■■■■■■■■■E\s!�■■■■■■■■\��\NOON■\\■\\■�■�■■■■■■■■■■ ■■■■■■■■\aw=nNi■■■■■■■■■■■■■■■■■■■\�� \■■■NOON\�\■■■■\\■►1■11■1■■■■■■■■■■ ■ ■■■■■�� ��■■■■■■■■■■■■■■■■■■■\�TIMEMMEN�T-■■■\1■\\IINI■■■■■■■■■■ 1 1 1 ■ MOON■■ ■i■■\ �� !1 NE■■■ ■■■■■ ■■■■■ ■\\Z\ 00000 NO\■\\ ■111'■I 100000 ■■■■■ ■A.. _ ■■ ■■■■■ ■■■■■ ■■■■■ \i !w ME■■■ ■■■■■ ■■■■\ i�.!4000 ■\\■L1 011■ 21100000 ■■■■a NOON■■\�� !��E�■■■■■■■■■■■■�■■\� !\�■■■■■NOON■■\�\■■►�■\'■■■�11■■■■■■■■■ NOON■ NOON■ NOON■ NOON\ �� �� \�■■■ NOON■ ■■■\� ��\■■ NOON■ ■►\\`■ 11■i II 11 I ■■■■■ ■■■■ ■■ NOON■ NOON■ ■■�■■ \a�� ■�■■■ NOON■■\�� \NOON ■■\\,\ \\11111 NOON■ NOON ZT ■ ■■■■■ BAR 1111 ■■■■■ ■■■■■ ■■■\e�.=!ONEM■■■■■■■■■■■■■■■■■■■■■■■■\aim■\■■■■■■\b\■■■\.\.\\1■ft1■■■■■■■■■' ■��!�■■■■■■■■■■■■■■■■■■■■■■■■■\M��■■■■■■\�\■■\`\`\NCI■■■■■■■■■ 1 • ■ ■■■■■ ��� 0-i■■■ ■■■■■ ■■■■■ ■■■■■ ■■■N0 \■■■■ ■\"■■ 111111 ■■■■■ ■■■■■ mAz a1■■■ NOON■ NOON■ ■\ate W■■■■ NOON■ NOON■ NOON■ \Z\■■ ■■■►`\ VOL 1111 NOON■ NOON NO�ON■\��� ��■■■■■■■■■■■■■■■\��_!■■■■■■■■■■■■■■■■\��■■■■►`■�\\'llll■■■■■■■■■� �i�SiliiJllB ON��� ��Ai iNNEN 0�000 MU��� \•i�M 0���0 MENEM \MMM\\ \� 111 00000 MENEM ■\��w■■■■■NOON■NOON■■■■■\ER M■■■■■■■■■■■\R\■■NOON■■OC■\`1\`1IINEON■■■■■■ ■ ���■■■_■■■■■■■■■■■■■■■\s!\■■■■■■■■■\�!\NOON■■\�■■�\\'I■■■■■■■■■■ a 11 .■■\one =--NNE■■■■■■■■■■■■■\ft=!'\E■■■■■■■\74\■■■■■\\■\\1■■■■■■■■■■ 0000000000 NOON■■\� ����■■■■■■■■■■■■■■■\��\■■■■■■■■■■\�\NOON■►`\■■■\`\ ■■■■■■■■■■ ■■■■■■■■■■■■\��� !�■■■■■■■■■■■■■\\���■■■NOON■■\��■■■■\`\■■\�1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■�i� !�■■■■■■■■■■■\� !\NOON■■■\��■■■►`■■■■1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■\��� �■■■■■■■■■\��\NOON■■■►`\■■►�■■■1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\���■■■■■NOON\��■■■■■■\\■\i■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\■NOON■■■\�\NOON\\■■■■1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\NOON■■■\�\■■■\�■■■1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\��\NOON■■\:■■■■■■■1■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\�!\NOON■►`\■■■■■i■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■NOON■■\�\NOON\`�■■■■■■■■■■■■■■■ 0 \OISTRIO, 980 080663) (AF N0. 9806080663) III I I I I �I' I III I I I ICI NO O25O OPE A PORTION SE 1 /4 OF THE SE 1 / ACCESS & UIILITY EASOAENE- GARAGE (AT NO. 201603295002) L \ \/ RX =843 \ Q EOUND EBAR AND o HOUSE RIDGE "LDC 48761" SEWER PUMP STATION \EL= 6' RIM: 228.5 I 3 4 E (4" S): 226.0 IE (2" E): 225.0 4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M. \ I I I NT40'31'W 36 WATER AND SEWER PLAN 1 SCALE: 1" = 20' WATER AND SEWER PLAN NOTES: 20 0 10 20 40 1. PLUMBING CONSULTANT TO VERIFY METER & SERVICE SIZE. SIZING TO BE CONFIRMED ONCE PLUMBING PERMIT IS ISSUED AND REVIEWED. 2. PLUMBING CONSULTANT TO VERIFY SIZE OF EXISTING SEWER STUB IS ADEQUATE FOR PROPOSED BUILDING. 3. A MINIMUM OF T SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC) AND SEWER, WATER, AND STORM. 4. A MINIMUM OF 5' OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN WATER AND STORM LINES. PUMP STATION CONTROL PANEL W/ ALARM AND LIGHT IE (2" FORCE MAIN): 226.50 IE (ELECTRICAL CONDUIT): 228.0 EXISTING GRADE ELECTRICAL CONDUIT 260 - - - - - - - - PROPOSED GRADE - - - - - - - - - - - 260 255 A 255 250 250 245 __.-. 245 240 .. ... 240 235 235 230 - I' 230 225 225 220 220 10 UP 8" DIP CASING SS STUB IE: 250.29 2" IPS POLY HIGH-MOL PIPE A FORCE MAIN AND ELECTRICAL CONDUIT PROFILE SCALE: 1" = 20' APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE - BY., _ CITY ENGINEERING DIVISION = cm I ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 O3/II/22 w 0 DESIGN: BJL DRAWN: ATD CHECK: JPU JOB NO: 21125.20 DATE: 12/03/21 N W J 3 0o W � LJJ 00 N w U Q LJI p 3: Z C) Z Q Z Q 0 N Z w Z ~ Q U I� Y La> Q > 0- SHEET C 4.1