ENG PROJECT ASBUILT - LFA PORTION SE 1 /4 OF THE SE 1 /4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M. HOUSE RIDGE EL = 56.6' o � \ TIE INTO EXISTING STORM STUBS \ 1 - , T SD �-�I Cv IE (6" NE): 2±8.8 218.U4 (AB) 'E E'_„' ` IE (6" E): 218.20 (AB) IE(6"NW):218.0- 220,"� � STEPPING STONE PER ARCH -------- PATH VOp�S��BPC Ai �65 5 . -- -�- D � FUUNU KLUAK ---\ \ '9 i \A A '\ -, / �D 9° 26 3 \ \ \ — BUILDING SET BACK LINE \27�.0�' _ — _- APPPnYIKAAT� nraTlnki GRADING AND DRAINAGE PLAN SCALE: 1" = 10' GRADING AND DRAINAGE PLAN NOTES: 1. THIS SITE IS DESIGNATED AS A STEEP SLOPE CRITICAL AREA. 2. ALL DISTURBED AREAS ON AND OFF -SITE SHALL BE COMPOST -AMENDED PER THE REQUIREMENTS OF BMP T5.13 N THE STORMWATER MANUAL VOLUME V, CHAPTER 5. 3. TOP AND TOE REFER TO FINISHED GRADE AT THE TOP AND BOTTOM OF THE WALLS, RESPECTIVELY. 4. A MINIMUM OF 3' HORIZONTAL SEPARATION AND V VERTICAL SEPARATION IS REQUIRED BETWEEN DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC) AND SEWER WATER AND STORM, AND A MINIMUM OF 5' HORIZONTAL SEPARATION AND V VERTICAL SEPARATION FROM ANY CITY -OWNED LINES. 5. A MINIMUM OF 2' OF COVER IS REQUIRED FOR ALL PIPES LOCATED UNDER DRIVABLE SURFACES AND 1' OF COVER UNDER LANDSCAPE SURFACES. 6. PRIOR TO PLACING ANY SURFACING MATERIAL ON THE DRIVEWAY, IT WILL BE THE RESPONSIBILITY OF THE DEVELOPER/CONTRACTOR TO PROVIDE DENSITY TEST REPORTS CERTIFIED BY A PROFESSIONAL ENGINEER REQUIRED IN THE STATE OF WASHINGTON. Ai 7. NEW/REPLACED IMPERVIOUS SURFACE (INCLUDE PRIVATE DRIVE): 7,263 SF. ALL SITE RUNOFF ROUTED TO PUGET SOUND OUTFALL VIA DIRECT DISCHARGE. - NEW BUILDING: 4,861 SF ROOF AREA (INCLUDING OVERHANGS). RUNOFF ROUTED TO STORM DRAIN STUB THOUGH ROOF DRAINS. - NEW DRIVEWAY: 1,381 SF. RUNOFF ROUTED TO STORM DRAIN STUB THROUGH TRENCH DRAIN. -NEW WALKWAYS: 844 SF. RUNOFF ROUTED TO STORM DRAIN STUB THROUGH CATCH BASIN. 8. THE MAXIMUM DRIVEWAY GRADE IS 14%. Al 9. PIPE RUNS OF MORE THAN 1 STICK AT A SLOPE OVER 20% WILL REQUIRE ANCHORING. GRADING QUANTITIES TOTAL EXCAVATION (CUT) - 150 CU YDS TOTAL EMBANKMENT (FILL) - 760 CU YDS TOTAL 910 CU YDS THE QUANTITIES SHOWN ABOVE ARE FOR THE PERMIT PROCESS ONLY. THESE VALUES ARE APPROXIMATE. DO NOT USE FOR BIDDING, PAYMENT, OR ESTIMATING PURPOSES. \ \ \ \ 1. \ ROTECT EXIST! G ° M 10' UTI�TY EASEMENT HICKENED EDGE C (AF. NO. 2al k03295002) °� °M 6" TRAFFIC RAT EC3 COM_ .x TRENCH DRAIN 10' UTILITY EASEMENT (AF. NO. 201603295002) ENTRY MONUMENT FASFNAFNT (AF N(l� 10 0 5 10 (AB)DENOTES AS -BUILT VALUE "THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON CONSTRUCTION RECORDS AND AS -BUILT INFORMATION PROVIDED BY OTHERS. CG ENGINEERING HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THIS INFORMATION" APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION = (> 4m�lhh ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 J J J < < N Z Z Q Om W W 0 H F- F- J 0 m wwwWv) o a a a Q r1 c-I f V w���r14 F N m r1 a) Q 0 0 r1 0 N m I- r-1 0 r1 0 0 Q DESIGN: BJL DRAWN: ATD CHECK: JPU JOB NO: 21125.20 DATE: 07/02/21 Li V Q Z Q (n � N o Q O � w > rn 0 c) Q Z a Q IZ o Z Z (� La N Z Q O Z 0 Y N O :2 aQ c)r--,. La Lo 0 - W Y W (, E SHEET: C301 A PORTION SE 1 /4 VVA I tK AIVU JtWtK PLAIN IVU I tJ: 1. PLUMBING CONSULTANT TO VERIFY METER & SERVICE SIZE. SIZING TO BE CONFIRMED ONCE PLUMBING PERMIT IS ISSUED AND REVIEWED. 2. PLUMBING CONSULTANT TO VERIFY SIZE OF EXISTING SEWER STUB IS ADEQUATE FOR PROPOSED BUILDING. 3. A MINIMUM OF T SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC) AND SEWER, WATER, AND STORM. 4. A MINIMUM OF T OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN WATER AND STORM LINES. A OF THE 260: 255: 250: 245: 240: 235: 230: 225: 220. SE 1 /4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M. PUMP STATION CONTROL PANEL W/ ALARM AND LIGHT IE (-2a3" (AB) FORCE MAIN): 226.50 IE (ELECTRICAL CONDUIT): 228.0 EXISTING GRADE ELECTRICAL CONDUIT PROPOSED GRADE ......... ............................... .............................. ....... ............................... .o.............. ... ......................................... .. .. .......... ..... ..I... ........ .......... ....................... ...... ........ ...W.. �z . . J i w a ...... ........... ..................... ...................... .... O. ............................................. ............................... 10 LF - 8" DIP CASING SS STUB IE: 250.29 3" HDPE (AB) FORCE MAIN AND ELECTRICAL CONDUIT PROFILE SCALE: 1" = 20' 260 255 250 245 240 235 230 225 220 (AB1 DENOTES AS -BUILT 1 VALUE "THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON CONSTRUCTION RECORDS AND AS -BUILT INFORMATION PROVIDED BY OTHERS. CG ENGINEERING HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THIS INFORMATION" APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION 4= <> 4M�1116 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 /' �s GULL 4� of wash►, NOT = ?g oil) TRIF-if.TION J J J < < N Z Z � � Q m = =)w w 0 cn Ld w w w to o a a a Q c-1 c-I N Ld \ \ \ \ F N M c-1 a) Q O O r-I O p I- N m r1 O r-1 O O Q .-I N DESIGN: BJL DRAWN: ATD CHECK: JPU JOB NO: 21125.20 DATE: 07/02/21 LL V) Lli � � Q O L�J W 00 V / LLJ W Q 0-) 0 v Z 0 Ld p Z 0 0 Z Q Z W r, 0 Z Z Y N O �� — U I� :2 Q W LdLo p �j Y � W C SHEET: C4.1 A PORTION SE 1 /4 OF THE SE 1 /4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W . M. C3�J Al NOTES: 1. WRAP AND TAPE 12 GAUGE TRACER WIRE EVERY 10' TO THE FORCE MAIN. 2. THE LOCATION OF THE STUB SERVICE TERMINATION SHALL BE MARKED BY THE CONTRACTOR WITH A 2'x4' TIMBER EXTENDED VERTICALLY FROM THE PLUG END TO A MINIMUM OF 3 FEET ABOVE THE GROUND SURFACE. IN ADDITION- • A 12-CA►UGE GALVMIQED WIRE SHALL BE ATTACHED TO THE TIMBER FROM END TO END ENSURING THAT NEITHER THE WIRE NOR THE 2"x4' TIMBER SHALL BE ATTACHED TO THE SEWER PIPE OR PLUG. • THE EXPOSED PORTION OF THE 2"x4" TIMBER SHALL BE PRE -PAINTED TRAFFIC WHITE WITH THE WORDS "GRINDER PUMP SEWER CONNECTION' STENCILED ON WITH BLACK PAINT. • THE END OF THE 2"x4' TIMBER SHALL BE PRE -MARKED IN PERMANENT INK WITH THE LENGTH OF THE TIMBER INSTALLED. 3. GRINDER PUMP VENTILATION SHALL BE CONNECTED TO THE HOUSE SEWER VENTING SYSTEM, PER NFPA CODE_ DETAIL "A" CITY INSPECTION REQUIRED PRIOR TO BACKFILL GRINDER PUMP SERVICE ,u►NI Aity zois COTY OF EDMONDS CONNECTION TO PUBLIC WORKS GRAVITY SEWER MAIN STANDARD DEPARTMENT DETAIL APPROVED B R> ENGLISH DETAIL O CITY OF EDMONDS STANDARD DETAIL SCALE: NITS STAINLESS STEEL VALVE EXTENSION HANDLE 24" BASIN COVER SIMPLEXPIPE TRACER WIRE STRUCT PLASTIC JUNCTION BOFASTENED TO WALL STRUCT P�yf SST FASTENERS 1 1/2" CONDUIT i 2"-FINISHED GRADE FLANGE - z EY CONDUIT SEAL (REQ'D BY OTHERS) 0 ELECTRICAL RAIL MOUNTING FLANGE CONDUIT LIFTOUT CHAIN ANIT-SIPHON VALVE, I PVC (IF REQ'D) AIR VENT I CONNECT TO DWELLING I TOP HOLDDOWN PLUMBING VENTILATION LET FITTING, TY) FIELD RISER PIPE INSTALLED GRAVITY FLOW 4" INLET FROM DWELLING ' 2" HI-MOL POLY FORCE MAIN 2" BRASS MIP x IPS COMPRESSION FITTING WITH STAINLESS STEEL FIBERGLASS OR HIGH" STIFFENER DENSITY POLYETHYLENE BASIN -� HIGH WATER "ALARM" LEVEL SHALL BE A MIN OF 6" BELOW GUIDE PLATE INVERT OF 4" SEWER INLET z_ PUMP "ON" LEVEL N a RAILS DISCHARGE PIPE PUMP "OFF" LEVEL 4 SWING CHECK VALVE & DISCONNECT ASSY d.. GRINDER PUMP A ° DISCHARGE CASE a c ANTI -FLOATATION PLATE ° OR FLANGE CONCRETE ANTI -FLOTATION BASE NOTES: 1. REFER TO CITY HANDOUT E61 FOR ADDITIONAL DESIGN AND PERMIT REQUIREMENTS. 2. ASSEMBLIES SHOULD NOT BE PLACED IN AREAS SUBJECT TO VEHICULAR TRAFFIC. IF LOCATED IN TRAFFIC AREAS, THE LID SHALL BE TRAFFIC RATED AND SHALL BE INSTALLED FLUSH IN ASPHALT OR CONCRETE. CITY INSPECTION REQUIRED PRIOR TO BACKFILL REVISION DATE 24" SIMPLEX GRINDER JANUARY 2018 1CITY OF EDMONDS PUMP WITH REMOTE T PUBLIC WORKS MOUNTED CONTROL PANEL STANDARD DEPARTMENT DETAIL FS t . 18g� APPROVED BY: R. ENGLISH SS - 241 CITY OF EDMONDS STANDARD DETAIL RESIDENCE 1 1 2" CLEANOUT (MAX) (n'P) w z J Z w � a w w N CLEANOUT a 1n WITH 45' BEND AND CAP NOT TO EXCEED 100' BETWEEN CLEANOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2"± r- FINISHED GRADE z Ckf w w a 0 of a 3 i� d U WATER TIGHT CAP w RISER LEVELING COLLAR - 45' SEE NOTE 4 / 45 12" PVC SLEEVE J / 6" RISER 4" OR 6" SIDE SEWER 6" WYE AND GENERAL CLEANOUT DETAIL 45' BEND 12" LOCKING COVER SEE NOTE 3 END OF PIPER GRIPPER PLUG (CHERNE 27061 OR APPROVED EQUAL) 6" CITY STUB 4" OR 6" J 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL 3 SEE NOTE 3 AT PROPERTY LINEZCITY EASEMENT z w LEVELING COLLAR NOTES: Z ao N SEE NOTE 4 ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE _ GASKETED. 12"± 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS ONG 12" PVC rEND PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED EQUAL. 6" RISERIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: ERNE 270261 / OR APPROVED EQUAL) • IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24%6" DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP UNDER ASPHALT OR CONCRETE CONCRETE COLLAR REVISION DATE CITY OF EDMONDS JANUARY 2018 SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S S- Z O O CITY OF EDMONDS STANDARD DETAIL SCALE: NITS 30" BASIN COVER STRUCT PLASTIC WATERTIGHT LID RIM = 229.5 1 1/2" CONDUIT FLANGE I EY CONDUIT SEAL (REQ'D 1.5' MIN BY OTHERS) ELECTRICAL ELEV 228.0 CONDUIT ELEV 227.0 AIR VENT CONNECT TO DWELLING PLUMBING VENTILATION INLET FITTING, TYP (FIELD INSTALLED) �a GRAVITY FLOW 4" INL EV EL226.0 FROM DWELLING FIBERGLASS OR HIGH DENSITY POLYETHYLENE RIBBED PUMP BASIN 2.0' MIN GUIDE PLATE ELEV 223.0 a d PUMP "OFF" 2 0' LEVEL SIMPLEX JUNCTION BOX STRUCT PLASTIC - STAINLESS STEEL VALVE EXTENSION HANDLE - PIPE TRACER WIRE FASTENED TO WALL - SST FASTENERS F 2 /- FINISHED GRADE 1.01 1 RAIL MOUNTING FLANGE LIFTOUT CHAIN 3.0' MIN ANIT-SIPHON VALVE, PVC (IF REQ'D) TOP HOLDDOWN RISER PIPE ELEV 226.5±.q� 2"+if-Po96� P6E1'HDPE (AB) FORCE MAIN TO CATCH BASIN 1 1/4" BRASS MIP x IPS COMPRESSION FITTING WITH STAINLESS STEEL STIFFENER ELEV 225.5± HIGH WATER "ALARM" LEVEL (SHALL BE A MIN OF 6" BELOW INVERT OF SEWER INLET) PUMP "ON" LEVEL ELEV 224.54. ° RAILS a DISCHARGE PIPE ° SWING CHECK VALVE d & DISCONNECT ASSY DISCHARGE CASE T GRINDER PUMP 1.90' SEE NOTE 1 d � ANTI -FLOATATION PLATE OR FLANGE. ADEQUATE d CONNECTION OF CONCRETE TO PUMP BASIN. a 1.0' 95/' CONCRETE o COMPACTED CSBC ANTI -FLOTATION BASE CITY INSPECTION REQUIRED PRIOR TO BACKFILL NOTES: 4.00' 1. DUPLEX ZOELLER MODEL 840 DUAL SEAL GRINDER PUMP SYSTEM OR APPROVED EQUAL IN 36" DIAMETER, 7' DEEP PUMP BASIN W/ 2" PVC DISCHARGE PIPE. TO ORDER: CONTACT THE FOLLOWING ZOELLER PUMPS AUTHORIZED DEALER: PACIFIC PLUMBING SUPPLY CO. 7115 WEST MARGINAL WAY SW SEATTLE, WA 98106 206.762.5920 2. 33.4 CUBIC FEET IS REQUIRED FOR THE CONCRETE ANTI -FLOTATION BASE. 3. ELECTRICAL CONTRACTOR TO PROVIDE/RECOMMEND NEMA 4X ALARM PANEL CABINET W/ RED LIGHT AND ALARM PER MANUFACTURER, 100 DB MIN. PROVIDE EMERGENCY GENERATOR POWER BY TRANS GENERATOR AUTOMATED SYSTEM OR PORTABLE GENERATOR SYSTEM APPROVED BY OWNER. 4. A BATTERY -OPERATED BACKUP POWER SUPPLY FOR THE ALARM SYSTEM IS REQUIRED. 5. CONTROLS SHALL AUTOMATICALLY RESTART AFTER DISRUPTIONS IN POWER SUPPLY. 6. THE SEWER PUMP DISCHARGE LINE SHALL BE PROVIDED WITH AN ACCESSIBLE CHECK VALVE AND GATE VALVE WITHIN THE TANK. 7. A 4" CLEANOUT IS REQUIRED ON THE GRAVITY SEWER LINE BETWEEN THE BUILDING AND THE GRINDER PUMP. PROVIDE 5' CLEARANCE BETWEEN HOUSE AND PUMP CHAMBER. 8. USE EXPANSION FITTING TO INCREASE PIPE DISCHARGE LINE TO 2" DIAMETER PRIOR TO EXITING THE PUMP BASIN. PUMP BASIN SCALE: NTS (AB)DENOTES AS -BUILT VALUE "THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON CONSTRUCTION RECORDS AND AS -BUILT INFORMATION PROVIDED BY OTHERS. CG ENGINEERING HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THIS INFORMATION" APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 fA J J Jaa�, ~ ~ z H z m > > < � w w � cn w w w w V) CL d Q N M r-I M Q O O O C) r_ N M O O O Y Q rl N DESIGN: BJL DRAWN: ATD CHECK: JPU JOB NO: 21125.20 DATE: 07/02/21 3:: N O W L u 00 U Q Z Q LLJ 0 0 Z W w r., V / O N Z Y N O U I� M W ul p Y � Ld SHEET: V A J Q Lj 0 LL Lj 3:7 Li Lj V A Z Q LL Lj I- w z J C4.2 SCALE: NITS