REV2 APPROVED ENG BLD2021-0985+SEWER PUMP CALCS & INFO+2.3.2023_3.31.14_PM+3351077C �
ENGINEERING
civil & structural
engineering & planning
ENGINEERING DIVISION
APPROVED AS,,,, NOTED
-Vay ri" r�n03/10/2023
on behalf of Mike De Lilla
City Utility Engineer
Sewer Pump Revision
Sewer Pump Substitution
Pump alarms are set to alternate,
even in alarm mode. There will
only be one pump on in all
conditions.
250 4' Ave S Ste 200
Edmonds, WA 98020
Phone: (425)778-8500
Fax: (425) 778-5536
REVISION
Feb 03 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2021-0985
Sewer Pump Calculations
Keck Residence
15722 72nd Ave W
Edmonds, WA 98026
02103123
CIS Project No.: 21125.20
Keck Residence - CG #21125.20 February 3,2023
Pump Calculations Page 1
This package contains:
- Flow Rate Calculations
- Headloss Calculations
- Pump Elevation Specifications
- Storage Calculations
- Cycling Calculations
- Buoyancy Calculations
- Pump Literature/Specifications
- 11x17 Water and Sewer Plan Sheet
The calculations contained herein demonstrate that dual Zoeller Model 840 Grinder Pumps with a 2"
discharge pipe would be sufficient in the subject project's application. The pump basin has been sized as
a 36-inch diameter basin with a depth of 7'-0". For repair and maintenance, contact the following
Zoeller Pumps authorized dealer:
Pacific Plumbing Supply Co.
7115 West Marginal Way SW
Seattle, WA 98106
206.762.5920
C 250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENGINEERING ph.425.778.8500 1 f.425.778.5536
www.cgengineering.com
Flow Rate Calculations
Flow rate based on peak water demands of fixtures for
proposed house.
* Water Supply Fixture Units from 2015 Uniform
Plumbing Code, Table A403.1 (attached)
From Chart A103.1(2) (attached),
demand —PO
43 gpm
.100 cfs
Pump Calculations
By BJL
Date 2/3/2023
Flow Rate Calculations
Chkd
JPU
Date
ENGINEERING
scale N.T.S.
Sheet No.
250 4th Ave. South
Job No.
Suite 200
21125.20
Edmonds, WA 98020
Keck Residence
Fixture
# of
Fixtures
WSFU*
Total
Units
Bath Tub
1
4.0
4
Clothes Washer
1
4.0
4
Dishwasher
1
1.5
1.5
Kitchen Sink
1
1.5
1.5
Laundry Sink
1
1.5
1.5
Washup Sink
6
2.0
12
Bar Sink
1.0
0
Mop Sink
1.5
0
Shower Head
3
2.0
6
Water Closet, 1.6 gpf
5
2.5
12.5
Total
43
TABLE d< 1(0.1
WATER SU€KY FI%Tljlib UNITS (WSFU) ANOBUNCUUM FA[TURE BRANCH PIPE 3=33
ARRIAMM&AI"R,ff9MVY#=ORFIXTURES'
�4# W w FIX741+E
��ve
I��ap
PRWATP
Pk
� +d�rYS
HadMUb Or C4nn*d iQn 5
Y, i nch 84101tub Fill I Vah+t
?:
10.0
10.0
-
Didd
'A
IA
-
-
00(ks WaNli-ir
Ih
4_0
4A
-
Den W k; rki .vmrdor
'A
-
]JD
y
k}i+h>k'a'trer.&MC!Sut
'h
1.5
1.5
-
tkirkkit4roulftnIfLotwolefco*r
14
05
0.5
p,7S
}Drat Bibb
'h
2.5
2.5
-
Hose E ML tech add Kiarul7
'h
1 A
1A
-
Lxvakmy
'h
1.0
1_0
1.0
1.z;%-n lipmLlierr, 4Mq;hhgad}
1.0
1_0
Ntt)bi 6e I'k. rM4, coca (ramai %= M
-
110
-
-
�Q11L 4
ChaKarFs�Icel
'h
-
-
Fliokaj €Im]Iarmwr Vahve wih ur wihimn faueel
I-
Ki6chm &Xwaic
A
1.5
1-5
-
Li
'A
1_5
)_S
-
!k"iCSOr MopUaLirk
13
3.0
-
ww r . "Kh Xq 9f au"M
Ih
4
2 0
-
$ti mw pw hesi
'h
2.0
?.0
-
4lr69. r.OGPFFIMaK ierVahe
'
M
4A
$.O
4Jriaal, gotaoff Alan 1 JU GPF FIMaM r tkF Vatre
'.
3A
5A
(KID
Urm4Okuhtw&
IA
2.0
2.0
].0
V1'sthrMvAMM.6radarspray
M
Wa-crClknM 1.6GPFFl:�hmxlrrTsr&
a_5
].S
WAwCtizeL 1.6GPFFLutrw*m*FVOJVt
1Yat-crChnol,g btFdxanl-6GPFGrsrrilyT=k
'h
3.0
S_5
7.16
Vk'alarCer. Orin 1ACiPF Flu,hgrneoer %'altie
I
7.0
#0
I"
Rie Sl qEiu; I iah -' ereti
Ndxi
r Svc ofWhevddbnW*bFpr.arLWhmehdwdcold kwrbppcL
A(fli&ifty, *paReaaotar_ ry IAMcs no arptN&d an OFu labia Mall b<preftw W w be s rrvd by rrfok*;r Io- frtirrtm brF* a A"br rPow ii r aid At-
q&MUOfwF
s The kale Aximwrtvdrxs rcpn-c iii or aad keden the eoW;%swb,.Id-r% iy.'Fkc o4iw*. Glvwk sad%wwamr rh-
hres tuv* bo& cold wwl hra wakr rnar: Km -R hOl br FL,...! cd ta ex A be rakm as (hmr-qmlrn or rAr hdk d Ow vww of 0,,r i6ow,
a The aFppiy keixh part ,rep For,odi++lwl fkEwci at r1x roan,l (�D )pir K .ot
a For fiiiuror ar uWly mmwchom Irly Ia art4t ,c conrinuaur Sow domau h, dclQmhw iire re,}red Raw im pAona pw w > Ipm) ") and dd id
,MaklylaIfrtdermm4ieiim11.+aorwOwd+rnlSu..on,}t4mxpgE rMdKrhof.
# AmcibblyIP&txUw(xvTaW422.1()_
s Kcd4:A AmMiz-urar kudrnV *be addilk" hwc brbkR a Io b. rrrd -iftic -.=g wul builbr.,g d<srard wA For pIPcsvug wk-rc gYrrclhmovic bme
brbbuwppNdbyaxgncovfwaWd iitubv4pgs.T;hcrhmcbWxNWcwTi.hmetrbb"Iberrre+d-Mftbaarrof:SfixRWcvest,•.
CHART 103.1{1)
E STI MATE CU RVE S FOR DEMAND LOAD
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■■■■■■
■■■■■■i:
■■■■■
Rp■
■■■■■
sommmorldrAm
i!J
10000.4,10
0 ,Y) 1001 1500 LI)O') 25Y7
FIXTURE UNITS
FbrSl writs: t _�Ellbn Ix-rmmutr=0.06 Us
1O0
Z
6o
40
0
20
w
a 0
CHART A 1011(2)
ENLARGED SCALE DEMAND LOAD
:3'YJO
20 40 6O aU 10-0 120 140 16O 120 200 0 240
FIXTURE UNITS
Fcr SI units: t .8jA i per n7Lnute = 10.06 Us
Headloss Calculations
Total Headloss (HT) = Headloss due to friction (Hr) + Elevation Difference (Az)
HT=Hf+Az
Need to find velocity (v), Reynold's Number (Re), Relative Roughness (R), friction factor (f)
and equivalent length of pipe (Lc).
Assumed Pipe Diameter, D (in.) = 2.0
D (ft.) =1 0.17
Velocity, v = Q/A
A = IIrZ = 0.023 ft
2
v = 4.35 ft/s
Reynold's Number, Re = Dv/v
v = Kinematic Viscosity of water (50° F) = 1.41E-OS ft2/s
Re = 52423
Relative Roughness, R = E/D
PVC = 5.00E-06 ft
R = 3.00E-OS
Friction factor, f = 0.037 (see attached Moody Diagram)
Pump Calculations By BJL Date 2/3/2023
ENGINEERING Headloss Calculations cr,ka JPU Date
250 4th Ave. South scale N.T.S. Sheet No.
Edmonds, WA 98020 1 Keck Residence Job No. 21125.20
Headloss Calculations (continued)
Equivalent Length (Le) of flanged PVC fittings
Fitting
# of
Fittings
Le*(ft.)
Total Le
(ft.)
45' Elbow
1
1.7
1.7
Expansion Fitting
1
4.5
4.5
90' Elbow
2
3.1
6.2
Check Valve
1
19.0
19
Gate Valve
1
2.6
2.6
Total
34
* Le values from engineeringtoolbox.com
Le,tittings = 34.0 ft
Le,pipe exit = KLD/f KL = Loss Coefficient, D = Diameter (ft), f = friction factor
KL = 1.0
Le,pipe exit = 4.6 ft
(Le) = Le,fittings + Le,pipe exit
(Le) = 39.0 ft
Friction Headloss, Hf
Hf = 13 ft
HT = Hf + Az
HT = 38 ft
Hf= f L v2 L = 207.0 (length of pipe from
2Dg pump basin to main + Le)
Elevation Change: 25 ft (Oz)
Pump Calculations By BJL Date 2/3/2023
cbi d Date
ENGINEERING Headloss Calculations JPU
250 4th Ave. South Seale N.T.S. Sheet No.
Edmonds, WA 98020 Keck Residence lob No. 21 125.20
Pump Elevation Specifications
Pump Elevations
Rim
229.5
Fin. Grade
229.40
Inlet
226.00
Alarm On
225.5
Pump On
224.5
Pump Off
223.00
Base
222.50
Storage Calculations
(1-2" below rim)
(6" below inlet)
(Y of effective storage between IE and Pump Off)
(6" above base for dead storage)
Effective storage occurs between the inlet IE and the "Pump Off" elevations.
Diameter of Pump Basin = 3.0 ft
Volume = IIr2h
Volume = 21.2 ft3
Volume = 158.6 gallons of storage
Cycling Calculations
Pump Off = 223.00
Pump On = 224.5
Apump basin = 7.1 ft2
Discharge volume, VD = Von - Voff = 4.9 ft2 * (53.0 - 51.50)
VD = 10.6 ft3
VD = 79.3 gallons discharged
C Pump Calculations By BJL Da1e 2/3/2023
ENGINEERING Pump Elevations, Storage Chka JPU Date
250 4th Ave. South Calcs & Cycling Calcs scale N.T.S. Sheet No.
Edmonds, WA 98020 1 Keck Residence I
Job No. 21 125.2O
Cycling Calculations (continued)
Qin = 43 gpm
Qnut = 44 gpm (pump output for 38 ft of head)
Cycle Time, T = time for pump to clear basin and fill up again under peak flow rate.
Q = Qout - Qin = 1 gpm
Time to clear, Te = Vn/Q = 79 minutes
Time to fill, Tr = VD/Qin = 1.8 minutes
T = Te + Tr = 80.8 minutes per cycle
Cycles per hour = 0.7 cycles per hour (during peak flow)
Cycles per hour per pump = 0.4 cycles per hour per pump (during peak flow)
*Pump has sufficient outflow to cycle the peak inflow, which
Buoyancy Calculations is expected to only occur in short durations.
FB = Vs * pw; V, = Volume of Sump; pw = Density of Water; FB = Buoyant Force
Vs = Apump basin*Hpump basin
Vs = 53.0 ft3
FB = 3308 lbs
Hpump basin = 7.5 ft pw (pcf)=
To prevent flotation, we need Fe = FB; Need to find volume of concrete required to resist
flotation.
Fc = pcVc - pwVc ----> Fc = Vc*(pc - pw) ----> Vc = Fc / (pc-pw) Fc = Concrete Force
Fe = 3308 lbs
pe = 145 pcf
VC = 40.0 ft3 of concrete required to resist flotation
Vc,20% Fos = 48.1 ft3
See attached sketch of Anti -flotation device for reference.
VC = FTr2H + (2ft)*(Aouter - Ainner)
H = 3.90 ft
C � Pump Calculations
ENGINEERING CVclinq and Bum
250 4th Ave. South Calculations
Amonds, WA 98020 Keck Residence
62.41
Aouter (ft)= 12.57 Ainner (ft)= 1 7.07
By BJL Date
Chkd JPU Date
Scale N.T.S. Sheet No.
Job No. 21125.20
2/3/2023
Trusted. Tested. Tough* 0,
Product information presented f:1
here reflects conditions at time of publication. Consult factory
regarding discrepancies or PUMP COMPA
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502� 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
TECHNICAL DATA SHEET '
MODEL 840/841/842
DUAL SEAL GRINDER PUMPS
Pump Systems And Controls
SECTION: 2.25.070
FM2799
0622
Supersedes
0721
Visit our website:
zoellerpumps.com
PRODUCT SPECIFICATIONS Model 840
(Reversing Grinder Pump)
CC
0
Q
Horse Power
2
Voltage
200 - 575
Phase
1 or 3 Ph
Hertz
60 Hz
RPM
3450
Type
Capacitor start I capacitor run or 3 Ph
Insulation
Class F
Amps
4.5 - 20.0
CL
dMax.
Operation
Nonautomatic
Discharge Size
1-14' NPT vertical or horizontal
Cord Length
20' (6 m) standard
Cord Type
SOW or SCOW, multi wire neoprene
Max. Head
125' i38.1 ml
Flow Rate
59 GPM (223 LPM1
Max. Operating Temp.
130 IF (541C)
Cooling
Oil filled
Motor Protect'on
Auto reset therms! ove-load 11 Ph),
thermal ssnsar 0 Ph) Moisture Sensors
„_jj
Q
CC N
QImpeller
Cap
Cast iron
Motor Housing
Cast iron
Adapter
Cast iron
Pump Housing
Cast iron
Upper Bearing
Baal bearing
Lower Bearing
Ba'I bearing
Mechanics' Seals
Carbon/ceramic
Type
Non -clogging vortex
Impeller
Ductile iron
Hardware
Stainless steel 304
Motor Shah
Stainless steel 416
Square Rings
Neoprene
Cutter
Hardened stainless steel, Rockwell L55.60
c
t,s 51
Teck4 � s,� aura �n4
Ce"kd to CSA
sunaudC222M VA
11.21132
1296 my
4.11ts 6.15
1103 mmlI I164
1615 ml 4.1116[103mm I o
tt1 '206 mmj
1.114' • 11-112 NAT-
SK1323
44114' 1116 mm1 5�!' 1132 mml
SK1322
20.5m
1524 mml
23.3A
1603 mml
Models 841/B42
Vertical Discharge
11•11116 —
4,/ 1297 mml
4.11161103 mml �fi IR
1165 mm'
i
4.11161103mm1 c
12a6 mml
1-Ur- ".1-112 NFT.
1
51127 mml
SK2365
,D Copyright 2022 Zoellern Co. All rights reserved.
502-778-2731 j 800-928-7867 j 3649 Cane Run Road I Louisville, KY 40211-1961 1 zoellerpumps.com
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
MODEL
MG
841
842
Feet
Meters
Gal,
Liters
Gal,
Liters
Gal.
L"lers
5
1.5
45
170
54
204
34
129
10
3.o
45
17o
54
204
34
129
20
6.1
45
170
54
204
34
129
30
9.1
44
167
54
204
34
129
40
12.2
42
159
54
204
34
129
50
15.2
36
136
52
197
34
129
60
1 B.3
30
114
49
185
34
129
70
21.3
23
87
43
163
32
121
80
24.4
16
61
36
136
29
110
90
27.4
10
38
28
106
25
95
100
305
3
11
19
72
20
76
110
335
-
-
11
42
13
49
120
35.6
1
1-
4
1 15
1 4
15
Shut-off Head:
t 104 It 131.7 m)
1 125 It (38.1 m)
1 125 ft (38.1 ml
016532
36
32
20
24
12
MODELHEAD CAPACITY CURVE
I
NONE■■■
I
I
WEEEENE
"EEEE.
,.,,EEEE
E„1,EEE
E"'.EE
mom
1'■.E
■E■1,.ki■
Lr1ER5 a 4; 6a 12a 16a 200 24e
FLOW PER MINUTE
ELECTRICAL DATA AND CONTROL PANEL SELECTION GUIDE
A) Models
Weight
Volts / Phase
Amps
B) NEMA 4X Control Panels
840 REVERSING GRINDER
SIMPLEX
DUPLEX
E844•
137 lbs (62.1 Kg)
23011
1712
10-042a
10-0512
1840•
137 lbs {62.1 Kg)
20011
20.0
10-0420
10-0512
F840
132 lbs (59.0 Kg)
230/3
10.8
10.0634
10-0443
J840
1321bs (59.8 Kg)
200/3
12.3
10.0634
10-0443
G840
132 lbs (59.8 Kg)
46013
5.5
10-0599
10.0511
BA840
132 lbs (59.8 Kg)
575 / 3
4.5
Consult Factory
Consult Factory
841 SINGLE DIRECTION GRINDER
SIMPLEX
DUPLEX
E841 •
137 lbs (62.1 Kg)
230 / 1
17.2
10-1650
10.1652
1841 •
137 lbs (62.1 Kg)
20011
20.0
10-1650
10.1652
F841
132 lbs (59.8 Kg)
23013
10.8
10-1097
10-1125
J841
132 lbs (59.8 Kg)
20013
12.3
10-1097
10.1125
GB41
132 lbs (59.8 Kg)
460 / 3
5.5
10.1094
10-1122
BA841
132 lbs (59.8 Kg)
57513
4.5
10-1146
10.1168
842 SINGLE DIRECTION GRINDER
SIMPLEX
DUPLEX
E842•
137 lbs (62.1 Kg)
23011
17.2
10-1650
10-1652
1842•
137 Ibs (62.1 Kg)
200 / 1
20.0
10-1650
10-1652
F842
132 lbs (59,8 Kg)
230 / 3
10.8
10-1097
10-1125
J842
132 lbs (59.8 Kg)
20013
12.3
10-1097
10-1125
GB42
132 Ibs (59.8 Kg)
460 / 3
5.5
10-1094
10-1122
BA942
132 lbs (59.8 Kg)
57513
4.5
10-1146
10-1168
• Single phase units require a set of capacitors and relay starting components, included in panal
0) CONTROL PANEL
STANOARO FEATURES:
• NEMA 0 outdoor rating
• Automatic reversing circuit (840 model only)
• Audible and visual high water alarm
• Starting, control, and alarm circuits
• Thermal cut-out circuit (3 Ph only)
• Circuit breaker and rated motor contactor I Ph)
• Capacitors and motor starting relay on (1 PH)
• Motor protective switch (circuit breaker / phase
adjustable overloads) and rated motor contactor
(3 Ph)
• Alternating circuit (duplex)
• High water alarm light
• Internal seal leak light
• HQA switches and pilot fight(s)
• Terminal strips
• Padlock hasp
OPTIONS:
❑ Flasher for high water alarm light
❑ Manual reset of high water alarm
i7 Intrinsically -safe relays
❑ Elapsed time meters
O Dry auxiliary contact
❑ For other options, consult factory
A CAUTION All Installallon of controls protection devices and wiring shoo d be done by a qualified licensed electrician. All electr cal and safety codes should be
followed including the most recant National Electrical Code (NEC) and the Occupal'onal Safety and Health Act (OSHA),
m Copyright 2022 Zoeller" Co. All rights reserved.
502-778-2731 1 800-928-7867 1 3649 Cane Run Road I Louisville, KY 40211-1961 1 zoellerpumps.com
840/841/842 Horizontal Discharge Dimensional Data
840
10-118"
[257 mm]
4"
[102 mm]
4-9116"
(116mm] 100
9-118"
[232 mm]
l 0
I
23-114"
[590 mm]
20-5I32"
[512 mm]
6-118"
[156 mm]
1-114"NPT
2-718"
[73 mm]
7
SK3362
841/842
10.1R'
[267 mm]
4' 6.112"
mm] [165 mm]
4-
1102 mm]
8"
[203 mm]
23-314' [E
20-5/8' [524 mm]
1-1/4" NPT
3.15132'
[88 mm]
I
S K3354
® Copyright 2022 Zoeller" Co. All rights reserved.
502-778-2731 1 800-928-7867 1 3649 Cane Run Road 1 Louisville, KY 40211-1961 1 xoellerpumps.com
HORIZONTAL DISCHARGE ON A Z-RAIL SYSTEM
39-0137 & 39-013B Z-Rail
DUPLEX PANEL
(FIELD INSTALLED)
SOL94 FIBERGLASS COVER
VW 302 STAINLESS STEEI 1 irnur rnai r
FLOAT TREE ASSEMBLY
FLEX BOOT FITTING
BALL VALVE
DISCHARGE PIPING
GUIDE RAPS
CHECK VALVE
Z-RAIL BASE ELBOW
FIBERGLASS AFD
F+ ^�- 36' MIN 1
PIPE SEAL
(FIELD INSTALLED)
PIPE SEAL
(FIELD INSTALLED)
ALARM1LkG �
ON
OFF
SK3355
+D Copyright 2022 Zoeller° Co. All rights reserved.
502-778-2731 1 800-928-7867 1 3649 Cane Run Road I Louisville, KY 40211-1961 1 zoellerpumps.com
Trusted. Tested. Tough. -
Product intonation presented
here reflects cmdAins at We
of publication. Consult laclrey
regardar dnaesaWdu or
In d.
�e
zAqfAqf)T"
r1 L TO: P.O. BOX 16347 • Louin*, KY 402564347
SNIP T0: 3649 Cane Run Read • LoubW10, KY 40211.1961
TEL: (502) 778.2731. I (ON) 92&PLW - FAX: (502) 774-3624
COMPARE THESE FEATURES
• Float is constructed of durable PVClpolypropytene encasing
variable level switch
• Standard mechanical variable level control switches are rated
for 1151230 V, 5 Amps
• Low current mechanical variable level control switches are
rated for 125 VACI30 VDC, 0.1 Amps
• 1W7 Type SJOW CPI: cons standard
• Cords are available in 15-25-35-50 foot lengths
• Temperature rating of 140'F (60'C)
• Approximately 1.5" liquid leval differential In switching action
Variable Level Control Switch is normally open when hanging
vertically above liquid level. Switch closes when it reaches a few
degrees above the horizontal position.
APPLICATIONS
• Switch for simplex or duplex pump control and high level
alarm on electrical altemating control panel systems for
dewalering, effluent and sewage applications.
• Switch for APak• (use low current models)
• High level alarm switch
ADJUSTABLE WEIGHT (PIN 10-0689) provides an accurate
pivot point for suspended float switches.
• Gripper teeth on clip and weight channel securely lock float
cable into place.
• Cable weight ran be adjusted without the use of tools.
HOUSING: 11b 12oz, ae kg) z.e' x 3.3" (7.1 cm x 8.4 cm)
Impact-resislanl 8 rmn corrodible. PVC housing for Ngtdds up to Wr F (Or CI
CLIP: Injection -molded scetal plastic
WIREICABLE ACCOMODATEO: SJOW, S.17W,1er2,1EV3, IEM3 142,1413
SHIP WMGHT: 2 lbs. (32 oz)
FLOAT SWITCHES
Mechanical
Cord
Length
Mounting
Method
Standard
PIN'
Low Current
PIN"
10-0743
10.2060
15
Clamp
10744
10.2061
20 1
Clamp
10-1877
10.2062
25
Clamp
10-1878
1(1-21363
35
Clamp
10.1879
10-2064
50
Damp
10.1880
10-2065
15
Adjustable Weight
10.1681
10-2066
1 25
1 Adjustable Weght
10-1882
10.2067
35
10.1883
M20M
9
SECTION: 2.50.090
FMO526
0916
Supersedes
0713
Wfslt our web site:
zoellerpumps.com
VARIABLE LEVEL
CONTROL SWITCHES
CLAMP TYPE ADJUSTABLE WEIGHT TYPE
May not be exactly ens pktred Sea beck tot appllallon dravdnpe,
FLOAT SWITCH TREES
Mechanical
Cord
Mounting
Standard
Inldnsleally
Length
Method
PIN'
Safe PIN'
10.1456
10.1456
—
Tree Omy
10-1886
10.2069
15
13) IF Floats
8 Tree
10.1887
10.2070
15
(4)15' Floats
8 Tree
Adjustable Weigh! ' 0o not use with Intrlrnlcally safe control systems.
Adjusfa>,le Weight " For use with Intrinsically safe control systems only,
0 Copyright 2016 Zoeller* Co. All rights reserved.
Your Peace of Mind Is Our Top Priarity
Product info =tloh pn anted
here mracta Canditlans at lane
of publication. Consult factory
regrudhV dpsLrepanctes or
lntonslstencles.
(bZF
'tj
PUMP COMPANY
Zoeller Fan ly ul Wafer Solutions
SECTION: 2. AID
FM1936
0514
Supersedes
0603
MAIL T0: P.O. BOX 16347 • LouLMAe, KY 4025"347 visit our web site:
SNIP TO: 3640 Cane Run Road • Louisvft KY 40211-1961 www.zoatter.com
(502) 778.2731. 1(800) 928-PUMP • FAX (502) 774.3624
5ulnib4 Wlarkrl*r
=00 Amdadlarl .�"�a•
FLOAT SWITCH BRACKETS
• (For Use with Weighted Floats)
rim At
Also see FMO526 for Float Tree Assemblies for floats that use clamp type hangers.
PART NO: 10.0438
WEIGHT: 2 LBS. / N
z]
u2 DM.
NOu"WG HOLES
6 W4
X15 OIA HOOKS
(' �- HANG FLOAT SWITCHES. PGWER CORDS
3 OR LIFTING CABLES FROM (6) HOOKS
ITYR
• TYPE XW STA NLESS STEEL CONSTRUCTION.
• WILL OR ACCESS FRALIEMOUNTING zepaO299
�m
� yie
t/HdA
r!e
• srwrneaastE� �
0
CCRO CAW
. srNNLEs, enri
a
a
PART NO: 10-0253
WEIGHT: 9 LBS.
zePbo513
Bill CIA MOMM
1
/STRESS RELIEF BUSHOM
It 71fi
CONSTRUCTION.
MAY BE BOLTED OE•M TO RAIL SYSTM
UPPER GUIDE.
PART NO: 10-0436
WEIGHT.
I LB.
J L�
I 'r
I
r rlu ��l
r
ZINP...
0 Copyright 2014 Zoeller• Co. At rights reserves!.
BASIN
BUILDER
PROJECT INFORMATION
Project Name TITAN -CP
Contact Info
BASIC SYSTEM INFORMATION
Build Prepack ed
Type Duplex
Discharge Exit Swe
INTENDED PUMP DATA
Pump Divislon Zoeller Pump
Pump Family 820, 840, X840
Pump Discharge 1.25" Vertical
BASIN SIZE PREFERENCES
Diameter 36 "
Height 60 "
COVER PREFERENCES
Surface Solid
Material Fiberglass
Vent Quantity None
PLUMBING PREFERENCES
Inlet Hub 4" Pipe Seal
Discharge Piping 2"
Discharge Depth 24"
Pipe Material Stainless Steel
Shutoff Valve Ball Valve
DISCONNECT PREFERENCES
Class Stainless Steel
Rail Material Stainless Steel
DESIGN AIDS
Hub Invert Depth'
Is,.
Gallons / inch
4.41 Gal / In
Working Volume
79.3 Gallons
1 Hub Is neld Installed. Depth Is used to compute working volumes.
2 Usattlevolume between Inlet Invert and minimum water level.
ozatz"We
Zoeller Family of Water Solutions
Prepackaged Duplex Basin System, Pre -Plumbed, WI Rail Systems
(Stainless Steel Pump Lifting Cables Included)
Ball Valves &
Check Valves
Installed
No Vent Holes
In Cover
24 " to Cent
Side Discharge
Pricing Sign Below For Approval
Na
2 " Plumbing
S.S.
4" Pipe Seal
Loose
1.25" Vartical
Rail System
S.S. Hardware
ACCESSORIES
Lifting Lugs
ElectrIcal Coupling
1+
APProx. 440 tbs
Weight:
>— 36 " Die.
Solid Cover -
Fiberglass
S.S. Rails
60 " Tali
Fiberglass Basin
F.G. AFD Dia. 42.5"
No
Loose x2
NOTES: DRA WING IS NOT TO SCALE
PUMPS NOT INCLUDED - Pumps shown only for reference.
Systems Include check valves and disconnects as selected.
individual components may differ from those shown.
Customer Is wholly responsible for verifying code compliance.
Consult factoryfor basins larger than 72" dia. or 144" toll.
This Builder Is volld far use until 613012022.
V4.10
Trusted. Tested. Tough-
Product information presented
hero reflects condidoris at time
of publication. Consult factory
regardmQ dlscrependes or
inwnsta cin.
INCLUDED IN BASIN
�1 SECTION: Z60.1110
a� a WOW
0414
Supersede
PUMP COMPANY 4114
WIL 7O, PO. BOX 16347 - LoulsVlle, KY 40256-0347
SHIP TO: 3649 Cane Run Rand - Lovisv*, KY 40211.1961
TEU 1502) 779-2731 - 1 (800) 926-PUMP - FAIL (502) 774.3624
THE "FULL -FLOW" UNICHECKS
30-0163 1V CAST IRON NPT
30-0164 1%n CAST IRON NPT
Mara]
PMU
oj*w t Yn*�daa
51r» wR,rw.e",rrr
- Vertical or horizontal installation 30-0152
• Full -flow design, no restrictions 30-0160
• Stops backflow of water
• Standard, t W. I W. 2% T female NPT pipe
• Neoprene polyester reinforced Rapper, smooth edge
design with cast Iron and noncorrosive metal backing
plates A stainless steel fastener
• Corrosion -resistant powder coaled epoxy finish
• Rated al 50 PSI (115 feet of head) at 130T
Stainless steel bolts
1 per carton
Weight; 30.0163, 7.5 Ibs,; 30-0164, 7.5 Ibs.,
30-0152. 10 lbs.; 304160,1B lbs.
• Suitable for instalaton below basin cover
30-0021 2" PLASTIC SLIP X SLIP UNIONS
30-0151 2" CAST IRON SLIP X SLIP UNIONS
Full 2' flow design - meets BOCA (R604,2)
2' full flow pump code
• Checks badrAow of water and sewer gas
• Simple toinstall(nolhreadingo(piperequireeM,Save
time & material oasts
• Neoprene gasket and flapper, weighted with heavy
stainless sleet metal backing plates and rival
• Can be installed on vertical or horizontal line
• Slips over PVC, steel pipe or capper piping
• Reduces molorandpumpnoisefromplumbingsyslem
• 6 per carton
• Flexible neoprene siipxslipunionindudesstainless
steed damps for iowpressure syslems.Avoid more
than 10 ft. static head above the check valve. 4.3
PSI at 130-F
• Extra wide hinge to reduce hinge stress
• Plaslk: check has PVC body and can be Installed
with solvent welded couplings for pressure systems
to 25 PSI, 571t. of head (PIN 30-0023)
• Model 30-0151 has oorroskm-resistant
powder coaled epoxy finish.
• Plastic check individual rack pack Model 30-0022
Consul Factory or lacd represmWin for slate approv&
30-0181 1 V - V/V' SLIP X SUP UNION
30-0200 V* - V/2" SLIP X SLIP UNION W/ SS SCREW & CLAMPS
Flapper bends over a radius, no sharp 90' edges — lengthens Iffe of flapper hinge
PVC plastic check body, uhrasonically welded and can be solvent welded for rigid pressure rated piping
systems to 25 PSI, 57I1 of head at 1301 (304182)
• Slip x dip far 4,3 PSI, 10 it. of head at 130•F. Avold more than IOIL staltcheadabove the check valve.
• Vertical or horizontal Installation
• Avalable in individual packages for pegboard display (30-0181)
• A8 stainless steel screws, ruts and damps on model 30-0200 only
• Stainless steel damps with zinc screws on model 3MI81 only
• Designed to reduce water hammer
• 10 per carton
Wsh our web site;
roellerpumps.com
0
2" CAST IRON NPT
3" CAST IRON NPT
maim owa.,wy
s eww,e+arw,rrr
saa+s+
c.a hm
0 Copyright 2014 Zoeller Co. All rights reserved.
INCLUDED IN BASIN
Z-RAIL' DISCONNECT SYSTEMS (1-1/41' - 311 NPT Discharge Pumps)
FEATURES
• Sewage, storm water and effluent pump systems
• For concrete, steel, or fiberglass tanks
• Allows for removal of pumps from ground level
No confined space entry to service pump
No pull rods or hold down rods
• Disconnect fitting with positive machine fit and a -ring seal provides a reliable seal.
• Seals up to 160 psi, supports a weight up to 300 lbs.
• Guide rails direct the pump to and from the disconnect fitting. Systems are supplied complete with
disconnect fitting, guide plate, rail guide, and upper rail support bracket.
• All systems use 3/4' schedule 40 pipe rails (not Included).
2- Z-Rail" Disconnect System
PIN 10-3500, 10.3051,
Z 10-3829
mall?
s 40l
SPECIFICATIONS
Roll System
piPump a
"alacll hatae rn
Materiels of Construction*
Weight
Type
39-0134
1-1/4" V
2" V
powder coated, ductile iron
41
Z-Hall"
39-0135
1-1/4, V
2" V
Eowder coated, ductile iron wl SS upper roll support bracket
43
Z Rail°
39.0136
1-1/4" V
2" V
powder coated, ductile iron wl braes for non -sparking
44
Z•Rail°
39.0143
1.114" V
2" V
powder coated, ductile Iran w/ SS upper rail support/ brags for non-
sparking
Mail"
39-0137
1-1/4" H
1-114" V
wder coated, ductile Iron 1610/816 only)
41
Z-Rsil°
39.0138
1-1/4' H
1-114• V
powder coated, ductile Iron wl SS upper rail support bracket
18101815 onlyl
43
Z-Reilo
39.0131
1-1/2' V
2" V
powder coated. ductile Iron
41
Mail"
39.0132
1-12' V
2' V
wder coated, ductile iron wl SS upper rail suRport bracket
43
Z-Rail°
39.0133
1.1/2" V
2" V
powder coated, ductile Iron w/ braes for non -sparking
44
Z-Rail°
3"142
1-12' V
2" V
powder coated, ductile iron w/ SS upper rail support/ brass for non-
sparking
43
Z-Hall'
3MI28
2" V
2" V
powder coaled, ductile iron
42
Z-Rail*
39-0129
2" V
2" V
powder coated, ductile iron w/ SS upper rail support bracket
43
Malls
39-0130
2" V
2" V
powder coated, ductile iron w/ brass for non -sparking
45
Z-Raile
39.0141
2" V
2' V
powder coated, ductile iron wl SS upper roil support/ brass for non-
sparking
44
Z-Rail*
3M122
3- V
3" V
powder coated, ductile Iron
47
Z-Rail°
39-0123
3" V
3' V
powder tooted, ductile Iron w/ 5S u per rail support bracket
47
Z-Alit°
3MI24
3" V
3' V
powder coated, ductile iron 1 brass for non -sparking
47
Z-Rail°
39.0125
3- V
3- V
powder coated, ductile iron w/ SS upper rail support/ brass for non.
Bparkln
47
Z-Rail•
ACCESSORIES
lnlennedles ra/1 brackets are required for each 1Y of basin de rh.
39-0139
Intermediate rail bracket 1-114". 1-12' and 2" discharge - SS
4
Z-Rail°
3"140
intermediate stabilizer, SS, for 3' system
4
Z-Roil°
• • 103560
SS liking bail for 50. 90 & 150 saries
1
Z-Rail*
'" 103561
SS Ming bail for 140 series
1
Z-Hail,
•" 10.23111
SS lifting ball for 130.260 dr 270 series
1
2-Rails
• • 10.3829
SS lifting bail for 803, 805 8t 807 series
1
Z-Rail'
IG-0789
SS lifting bail for 160,180, 280, 290, 8101815 and SM8191820 series I5se above)
1
Z-Rail°
" Disconnect fining, guide rail plate, rail guide and upper rail suppon bracket SS lifting bail for 100. 180, 280. 290.8101815 and 81"1M20 series
•• Ufting trails ere required an these models to balance pump and rail plate evenly. Other models already include proper lifting device,
ID Copyrlghl 201 a Zoeller" Co. All rights reserved.
Notice to installing contractor: instructions must remain rnrith installation.
Trusted. Tested. Tough'" V
Product Information presented
here reRects conditions at time
or publication. Consult factory
reperding discrepancies or
Inconsistencles.
seglater your
Teelier Engineered product
on our webaft
hephYe9.rotdfareegprod.camf
DELLEi'P. e
ENGINEERED PRODUCTS
SECTION: Z5,00,165
ZM281a
0617
Supemades
0815
MAILT13: P.O. BOX 16347 • Louisville, KY 402WO347 visit our web site:
SHIP TO: 3649 Cane Run Road • Louisville, KY 407111961 ll1 Od.Corrl
1502) 778.2731 91 1000) 920-PUMP • FAX t502t 774-3624 2oeeren g�
INSTALLATION PROCEDURES ``
Z-Rail® Disconnect Systems
1-114"1 1.112", 2" and 31' NPT Vertical Discharge Pumps
General Information: These instructions cover Zoeller's Z•Raile
Disconnect Systems. These disconnects are designed for pumps with
a threaded vertical discharge. We also offer rail systems designed
for flanged discharge pumps, see ZM1170.
General Construction: Major system components, disconnect fitting,
guide rail plate and upper rail support bracket are made of powder
coaled epoxy ductile iron. The optional Individual stabilizer bracket is
stainless steel.
Llfiing Cable: Stainless steel lifting cables are available. These cables
are designed to attach to the lop of the pumps and allow the pumps to
be safely hoisted up and down guide rails. For 6160, 6180, 6280, 6290
and 7010 seftes, use PIN IN789 stainless steel lifting ball to properly
position lifting cable on top of pump.
Rail Support Bracket: The system Is designed to be used with 314'
schedule 40 galvanized or stainless steel rail pipe, which is provided
by others. A top rail support is designed to be mounted to the hatch
frame. Intermediate brackets are available for deep Installations. It
is recommended that if the rail length is over 12 feet, an intermediate
bracket be installed.
INSTALLING RAIL SYSTEM PARTS
Disconnect Fitting and Rails:
1. Lower the disconnect filling Into the basin.
2. Position the disconnect fitting by dropping a plumb line from the
center of pipe supports, located on the upper rail support, to center
of rail pins protruding from the fitting. Level its mounting flange in two
directions 90' to each other. Mark the position of the filling, holding
down bolls through the holes in the base.
3. Move the Titling aside to allow for installation of 112" mounting bolts
(not included). Secure fitting in mounting bolts.
4. Cut the 3140 pipe guide rails (supplied by others) to the proper length
and instal them between the upper rail support at the top of the
basin and the pins on the fitting. The guide rails are to be 314" pipe
schedule 40, galvanized or stainless steel.
IMPORTANT; Discharge pipe and guide rails must be parallel if
Intermediated guide bracket Is used.
INSTALLING INTERMEDIATE GUIDE BRACKET (Required forbasin
depths greater than 12'.)
1. Remove guide rails and cut a piece from each one. These pipes
must be exactly the same length and of a length that will pennil
Installing the intermediate guide bracket in the desired location.
2. Place the cut pieces of pipe over the guide rail pins located in
the base.
3. Set the intermediated guide bracket in position with guides into pipe.
Put u-boll around discharge pipe and tighten lightly.
4. Measure from joint on plug on intermediate guide bracket to Joint on
plug on lop nail support and cut two (2) rails to the length. Put rails
in place and tighten screws in top of support.
5. Recheck rails; they must be straight and plumb. Move Intermediate
guide bracket if necessary to perfectly align rails. After alignment Is
secured, lighten nuts on u-bolt.
6. If a second Intermediate guide bracket is used, the above procedure
Is followed for installation.
ATTACHING THREADED DISCONNECT TO PUMP
I . Remove pump elbow from the guide tall plate. Three cap screws
hold elbow to the guide rail plate.
2. Thread elbow Into pump volute.
3. Reassemble guide rail plate to pump elbow. Ensure o iing between
guide rail plate and pumpelbowremains intacl.Tighlen 3capscrews.
4. Attach theliffing bail (PIN 10-0789) tothe pump, 11notlaclory Installed.
5. The guide rail can now be slid down the rail pipe for mounting the
disconnect filling
INSTALLING PUMP AND DISCONNECT
IMPORTANT: When lifting pump up and down the guile rails, the
pump should be slightly tipped forward toward the discharge and
plumb (vertical) from side to side when facing the discharge.
Position pump so the guide rails are located in the slots of the guide
plate. Slowly lower the pump down the guide rails to the base. The
angled surface of guide rail plate should come to seat In the Inclined
surface 0n the arms.
After lowering the pump down the guide rail, secure the upper end of the
lifting cable to the lop rail support to keep It from falling Into the pit.
0 Copyrighl 2017 Zoeller' Co. A11 rights reserved.
SPECIFICATIONS
Rail System
Pump
Discharge
Rail System
Discharge
Motorists of Construction•
Wolght
3MI34
1-114' V
2' V
Ductile Iron, powder coated epoxy
41
30.0135
1-114" V
2" V
Ductile Iran, powder coated epoxy with S5 upper rail supports
43
3MI36
1-114" V
2" V
Powder coated ductile Iron I brass for non-sparWng
44
3MI43 I
1.114" V
2" V
Powder coated ductile Iron wl SS upper rall suep2q I brass for non-sporklnig
43
39-0131
1.112" V
2" V
Ductile Iron. powder coated epD
41
39.0132
1.112' V
2" V
Ductile Iron, powder coaled epoxy with SS upper rap supports
43
39-0133
1-112" V
2' V
Powder coated ductile Iron 1 brass for nonjerklN
44
39.6142
1-112" V
TV
Powder coaled ductile Iron W SS upper rail support I brass for norrsparkln
43
39.0128
2" V
2" V
Ductile Iran, powder coated epoxy
42
39-0129
2" V
21 V
Ductile iron, powder coaled epoxy with SS upper ran supports
43
39-0130
2" V
2" V
Powder coaled ductile Iron I brass for non-s orld
43
39 0141
2' V
2" V
Powder coaled ductile Iron w155 upper rap support 1 brass for non rkl
44
39.0146
Z" V
2" V
71 Series Grinder - Powder coated ductile iron
43
30.0146
TV
2" V
71 Series Grinder - Powder coated ductile Iran wl SS upper rail Support
45
39.0147
TV
2' V
71 Sertes Grinder - Powder coated ductile Iron 1 brass for non -sparking
43
39.0149
2- V
2" V
71 Series Grinder - Powder coated ductile Iron wl SS rall support 1 tress for non-e aridn
44
39.0122
3" V
3" V
Ductile iron, powder coated epoxy
47
39.0123
3" V
3" V
Ductile iron, powder coaled epoxy with SS upper rail supports
47
39.0124
TV
TV
Powder coaled ductile Iron I brass for non-sparkE
47
39-0125
3" V
3" V
Powder coaled ductile Iron wl SS upper rail support I brass for non-Rparkft
47
ACCESSORIES
lntafnmble rail brackets are required f w each it of basin dspfh,
temlediale Ral Bracket 1.114",1.112" and 2" discha - Stainless Steel
4
jMSS
termadlale Rail Bracket 3'distils e - Stainless Steel
4
IlItIng ball for 6150, M0, 6250. 6290 & 7010 Series
1
Disconnect filling, guide rail plate, rail guide, upper rail support bracket
•• Lifting bells are required on the following models to balance pump and tall plate evenly, other models Include proper lifting device.
NOTE: dldde Red Ph" to
a• (39-0122) Z-RaiP Is Not
IA'eaded (see a4 INi cnwkW,
for dab rnshOdw
ITEM NO
DE
1
GSCMNE T FITTING
2
INCLUDE PART NO 3456,7{SEE
BELOW)
3
PUMP ELBOW
L
-40"PARK)NQ,
5
55 SCREWS 131
6
INTERNAL KENO
7
GUIDE PLATE O-RING SEAL
-B
INTERMEDIATE RAILSUPPORT•SS
0
LIPPER RAIL SUPPORT BRACKET
DucTnE IRDN OR S
10
By NE S - 3ra RA1L
PI
OPTIONAL- REUUIREO FOR EAGR lir
SECTION OF RNL PIPE
DUCTILE IRON
PART NO. N 51ZE
39.11134 152631 i lfa•Y
3"131 152630 1 V3-V
3" 126 1532M 2 V
NON -SPARKING BRASS
PART NO N . SIZE
3"136 ism" 1-1N'V
3"133 152a76 1-1Ir V
3"130 152675 2V
3"12+ 152753 31v
ITEM 7
PARTNO SIZE
t523e7 1 1 1r4 1.112 r
152360 1 r r •rw s
0 Copyright 2017 Zoeller" Co. All rights reserved
LIFT STATION DIMENSIONAL DATA
1.114",1.112", 2" and 3" NPT Vertical Discharge Pumps
Z-Rail®Disconnect Systems
24 INCH DIAMETER MINIMUM SIZE.
48 tNCH DIAMETER MINIMUM SIZE FOR 71 SERIES.
1 `C
G B —r
H' I
F
E L
DOORFRAME
REF. PLANE
—D KANCHOR
. A ` BOLT (4)
ZOELLER RAIL SYSTEM
SIMPLEX DIMENSIONAL CHART
NOM. SIZE
A
B
1 C I Q
I E
I F I G
I H
I J
K
L
1.25 =2- DISCHARGE
4
7
3111 2.112
17.3/6
15-118 1 11.314
4
15.710
112
7-118
2' 71 SERIES GRINDER & r DISCHARGE
4
7
1 3.112 1 3-M
1 26
1 - 1 24
12
1 112
8
36INCH DIAMETER MINIMUM SIZE. A
48 INCH DIAMETER MINIMUM SIZE FOR 71 SERIES.
�C
M B
G
J
H
F
-E DOOR FRAME
REF. PLANE
K ANCHOR
BOLT (a)
ZOELLER RAIL SYSTEM DUPLEX DIMENSIONAL CHART
NOM. SIZE
A
B
C
D
E
F
G
H
J
K
!
M
1.2F-r DISCHARGE
4
7
4-M2
2
20
15.1I8
27.114
1544
13.518
112
6.1111fi
7412
2' 71 SERIES GRINDER & 3' DISCHARGE
4
7
4
7-718
29
-
30
15
112
12-711fi
7 318
WIN
0 Copyright 2017 Zoeller• Co. All rights reserved.
PUMP LIFTING CABLES INCLUDED IN BASIN
1/41' Lifting Cables for pump modals:
1-20 BHP Solids Handling Modals
71 & X71 Series Grinder Models
n
CABLE
C W;TN
ENT CAeLL
PERMAMEW SEW111A
CAUA CONNECTOR
Mum WAN
ReROW KI L A WO
CAKZ
CHOKER CABLE —�
r1cLIl0e mm
PMUOVAIM LI T04
CAME
ApMnoA 1r
REMOVABLE
UPNOrete
PIH
pruription
Materiel
WL Lbs.
6639-0025
ChakerCeble
Stainlonstael
I
6479-W27
ChakerCable
611veniredsteet
I
W394M
Permanent Cabe • 10'
Slainleas Sled
i
6639410Y9
I Permanent Cable- I0'
flsWenizsd Steel
1
6lt]9OM
ReatnvableCable-IG'
Stainlesisleel
5
ilk7SW
Removable Cable - Itr
Oalven4ed 5leel
5
663tD032
Permanent Cable -15'
Stdniess Steel
5
6Q79=
PemunentCable-20'
atalnlesisteel
7
509ml
Permanent Come -25'
StelolauSuel
8
60394 061
Permanent Cable • 311'
Stainless Steel
9
6039.OM
Removable Cable -15'
Stainless Steil
7
511311-CM
Ramov"Cable-20'
slow$$$Steel
0
M39036 -0
RemovableCalde-W
Stainless Sleal
9
We" removable lifting cable: 25-60 HP
64 HO and X64 HD pumps
PIN
peactiptieR
Material I
Wt. Lets.
60 11411 1
15' Cowl vrl rinC plates shackle
Stainless Sled
5
60]9-0t05
20'cable vdzinc plates shaeua
StairdeseSteal
5
6039-M
25' Cabk vvl zinc Oates shackle
Slainlas steel
6
6MOD97
30' Cable W/ zinc plates shackle
Stainless Steel
9
6039.0100
50' Cable Wl zinc pieta shackle
Suidess Steel
16
`Used with a NO LildnO 810
1/811 Stainless Steel Lifting Cables'
Part Number
Length
39-0031
8'
39.0032
124
39.0033
161
39-0034
20'
39-0035
24'
• Cable recommended for commercial duty
pumps and 2HP Grinder Pumps.
Rlgid Lifting Ball
zarAmrr
P010PSERif.S
Plfl
Material
Wt.lbs.
61 H>> 8 %61 HD
39�1115
Staidata Steel
4
62 NO 8 X67 HD
39-0115
5tsir/ea Stall
i
715%71
39�0T75
SeairtlefeSteel
1
61 H0
60i9-0W2
Suedau Stul
5
Xli1H0,l4-10HP
39�0175
SuhteuStee!
a
%61H0,56.60HP
39-0176
5leinhuSuel
5
m Copyright 2020 Zoeller
' Co All rights reserved
A PORTION SE 1/4 OF THE SE 1,
i ACCESS & UTUTY EASEMENT'-
I\ GARAGE (AF. NO, 201603295002)
\ \
/ Rx =400,
43
\ 12"(CPE -\ =2\l Q FOUND EB
AND
o HOUSE RIUGE "LDC 487E
SEWER PUMPSTATIO.5 �EL= 6'
RIM: 229.5
` 3 4 IE (4" S): 226.0
\ "\�4-, C4. IE (2" E): 226.5
-IRIBUION EASEMENT
(IF NO 980608O663)
NU
00
4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M.
I I
I
N ]'4p'31'W
- - -
--
360.]3 --
WATER AND SEWER PLAN
1 SCALE: 1"=20'
WATER AND SEWER PLAN NOTES: 20 0 30 20 40
1. PLUMBING CONSULTANTTO VERIFY METER & SERVICE SIZE. SIZING TO BE CONFIRMED ONCE PLUMBING
PERMIT IS ISSUED AND REVIEWED.
2. PLUMBING CONSULTANTTO VERIFY SIZE OF EXISTING SEWER STUB IS ADEQUATE FOR PROPOSED BUILDING.
3. A MINIMUM OF T SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC)
AND SEWER, WATER, AND STORM.
4. A MINIMUM OF 5' OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN WATER AND STORM LINES.
PUMP STATION CONTROL PANEL W/ ALARM AND LIGHT
IE (" FORCE MAIN): 226.50
IE (2ELECTRICAL CONDUIT): 228.0 EXISTING GRADE ELECTRICAL CONDUIT
260 - - - - - - - PROPOSED GRADE - - - - - - - - - - - 260
255 .Z 255
250 250
245 -_ 245
240 240
23s 235
230 l6 230
zzs o . 225
220 220
10 LF ^ 8" DIP CASING 55 STUB IE: 250.29
2" IPS POLY HIGH-MOL PIPE
A
FORCE MAIN AND ELECTRICAL CONDUIT PROFILE
SCALE: 1" = 20'
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY: _
CITY ENGINEERING DIVISION
C GM
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
GUI
4,G LL
^ G4.W pe�sy ^cn
`SrORAL
0VII/22
0
DESIGN: BJL
DRAWN:
ATE)
CHECK:
JPU
JOB NO:
21125.20
DATE:
12/03/21
N
W J
0o
W �
W 00
LLI
N w
U Q
Z
Q Z
N Z
W Z
Y CV O
I--
a
L)r�
LLI
Y A W
c y
SHEET
C 4.1
A PORTION SE 1 /4 OF THE SE 1 /4, SECTION 2, TOWNSHIP 27 NORTH, RANGE 6 EAST, W.M.
Al
NOTES:
1. WRAP AND TAPE 12 GAUGE TRACER WIRE EVERY 10' TO
THE FORCE MAIN.
E THE LOCATION OF THE SLAB SERVICE TERMINATION
SHALL BE MARKED BY THE CONTRACTOR WITH A 2•X4'
TIMBER EXTENDED VERTICALLY FROM THE PLUG END TO
A MINIMUM OF 3 FEET ABOVE THE GROUND SURFACE
N ADDMDN;
• A 12-GAUGE GALVANIZED WIRE SALL BE ATTACHED
TO THE TIMBER FROM END M END ENSURING THAT
NERHER THE WIRE NOR THE 2"%4' TIMBER SHALL
BE
ATTACHED 70 THE SEWER PIPE OR PLUG
THE EXPOSED PORTION OF THE 2"X4' TIMBER SHALL
BE PRE -PANTED TRAFFIC WHITE WITH THE WORDS
'GRINDER PULP SEWER CONNECTION' STENCILED ON
WITH BLACK PAINT.
THE END OF THE 2'x4' TIMBER SHALL BE
E PI -MARKED IN PERUME14T INK WITH THE LENGTH
OF THE TIMBER INSTALLED.
3. GAIN PUMP VENTILATION SHALL BE CONNECTED TO
THE HOUSE SEWER VENTING SYSTEM. PER HERA CODE
PROPERTY OWNER PUBLIC RIGHT-OF-WAY
DETAIL "A"
CIN INSPECTION REQUIRED
PRIOR TO BACKFILL
REVISION DATE
Y OF EDMONDS
GRINDER PUMP SERVICE
CONNECTION TO
GRAVITY SEWER MAIN
JANUARYN 2B
PUBLIC WORKS
STANDARD
DEPARTMENT
DETAIL
SS-21 O
APPROVED BY: W. ENBUSH
C
�
RESIDENCE
CLEANOUT
WNH 41'
BEND AND
CAP
CLEANOUT (MAX)
(TYP)
Nor To EXCEED 100' BEIwEEH CLEANouTs
CIEANOUT (HATE WITH CAP
AND CLEANOUT COVER) AND
CONCRETE LEVELING COLLAR
WATER TIGHT -W
7
45 7RISER
SEE NOTE 4
I
46
12' PVC SLEEVE
6' RISE
OR 6' SIDE SEWER
GENjk TLEANOLIT DETAIL
4; BEHAN
4' OR 6" �
12" LOCKING COVER
SIDE SEWER CLEANOUT DETAIL
�k
G
SEE NOTE J
LEVELING COLLAR
AT PROPERTY UNE�CTIV EASEMENT
NOTES:
SEE NOTE /
ASPHALT SURFACE
1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE
GASKETED.
-
12'3
2. PIPE SLOPE TO BE 2X MIN AND UP TO SOX MAX.
3. SEWER ClFANOUT COVER TO BE FAST JORDAN IRON WORKS
WHO 12" PVC
r.DOl
PRODUCT/00366102 STAR PIPE OOSP48L OR APPROVED
EQUAL
8' RISER
PE GRIPPER
4. LEVEUNG COLLAR SHALL BE CONSTRUCTED AS FOLLOWS:
RNE 270261
OR APPROVED EQUAL)
• IN ROADWAYS PER COE STD DWG GU-424
TYPICAL CLEANOUT
• IN SIDEWALK/LANDSCAPED AREAS, EITHER 24'x24"x6'
UNDER ASPHALT
OR CONCRETE
DEEP CONCRETE COLLAR OR 24' DIAMETER x 6" DEEP
CONCRETE COLLAR
REVISION DATE
CITY OF EDMONDS JANUARY 201e
SEWER CLEANOUT DETAILS
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
4f 'LOV_0 2r- R. ENGLISH SS -ZOO
CITY OF EDMONDS STANDARD DETAIL 2 CITY OF EDMONDS STANDARD DETAIL
B SCALE: NTS SCALE: NTS
STAINLESS STEEL VALVE
EXTENSION HANDLE
24" BASIN COVER
SIMPLEX PIPE TRACER WIRE
JUNCTION BOX FASTENED TO WALL
STRUCT PLASTIC
STRUCT PLASTIC SST FASTENERS
1 1/2" CONOUR
FINISHED GRADE
FLANGE
_f2.
3 EY CONDUIT SEAL '�11
5; (REO'D BY OTHERS)
ELECTRICAL
RAIL ROAMING FIANCE
CONOUR
UFTOUT CRAIN
"-SIPHON VALVE,
PVC (IF REO-D)
AIR VENT
CONNECT TO DWELLING
' TOP HOLDDOWN
I
PLUMBING VENTILATION
INLET FETING, TYP
(MEW INSTALLED)
I RISER PIPE
I
GRAVTY FLOW 4' INLET
RO FM MEWING
' 2' HI-MOL POLY FORCE MAIN
2" BRASS MP x IPS COMPRESSION
FIRING WITH STARLESS STEEL
FIBERGLASS OR HIGH
STIFFENER
DENSITY
POLYETHYLENE BASIN
HIGH WATER "ALARM' LEVEL
SWVl BE A IN OF B BELOW
GUIDE PLATE
INVERT OF 4' SEWER INLET
PUMP "ON' LEVEL
RAILS
PUMP "OFF'
DISCHARGE PIPE
LEVEL
' d SWING CHECK VALVE
4: DISCONNECT ASSY
GRINDER PUMP • '
a a
d ..
DISCHARGE CASE
4.
d ANTI -FLOATATION PLATE
OR FLANGE
CONCRETE
NOTES.
ANT -FLOTATION 845E
1. REFER TO CITY HANDOUT E81 FOR ADDITIONAL DESIGN AND PERMIT REQUIREMENTS.
2. ASSEMBUES SHOULD NOT BE PLACED IN AREAS SUBJECT TO VEHICULAR TRAFFIC. IF LOCATED IN TRAFFIC
AREAS. THE LID SHA1L BE TRAFFIC RATED AND SHALL BE INSTALLED PLUSH IN ASPHALT OR CONCRETE.
PITY INSPECTION REQUIRED
RIOR TO BACKFILL
\
24" SIMPLEX GRINDER
REVISION GATE
CITY OF EDMONDS
PUMP WITH REMOTE
JANUARY 2018
STANDARD
PUBLIC WORKS
MOUNTED CONTROL PANEL
DEPARTMENT
DETAIL
Esl. 1g90
SS-241
APPROVED BID R. ENGLISH
STAINLESS STEEL VALVE
36" BASIN COVER STRUCT EXTENSION HANDLE
PIASFIC WATERTIGHT LID SIMPLEX JUNCTION PIPETRACERWIRE
RIM =22SS BO%STRUCT PLASTIC FASTENED TO WALL
11/2" CONDUIT IrSIT FASTENERS
FLANGE 1 r 2 � FINISHED GRADE
I EY CONDUITSEAL(REDID 1.0'
1.5'MIN BY OTHERS)
ELECTRICAL RAIL MOUNTING FLANGE
oELEV 228.0
CONDUIT LIFTOUT CHAIN 3.0'MIN
ANIT-SIPHON VALVE, PVC
IF REQ'D)
*E V 227.0
AIR VENT CONNECT TO DWELLING TOP HOLDDOWN
PLUMBING VENTILATION
INLET FITTING, TYP RISER PIPE
(FIELD INSTALLED)
GRAVITY FLOW y ELEV 226.5±� "INL"INL
*ELEV 226.0 FROM DWELLING CATCH APTLY FORCE MAIN TO
CATCH BASIN
FIBERGLASS OR HIGH 11/4" BRASS MIP x I COMPRESSION
DENSITY POLYETHYLENE FITTING WITH STAINLESS STEEL STIFFENER ELEV225.5
M±�
RIBBED PUP BASIN
HIGH WATER "ALARM" LEVEL
T_ (SHALL BE A MIN OF 6" BELOW
INVERT OF SEWER INLET)
2.0' MIN GUIDE PPUMP "ON" LEVEL ELEV 224.51.0
LATE
RAILS
�ELEV 223.0 DISCHARGE PIPE
PUMP "OFF"
20' LEVEL a & DISCOING HECKVALVE
d ISCONNECT ASSY
GRIND ^ ° a A
DISCHARGE CASE
1.90, SEE NOTEI d
1 p ANTI -FLOATATION OF
ETE FLANGE. ADEQUATE
d � CONNECTION OF CONCRETE TO PUMP BASIN.
CONCRE E
95%COMPACTED CSBC ANTI -FLOTATION BASE CITY INSPECTION REQUIRED PRIOR TO BACKFILL
NOTES: 4.00'
1. DUPLEX ZOELLER MODEL 840 DUAL SEAL GRINDER PUMP SYSTEM OR APPROVED EQUAL IN 36" DIAMETER, 7' DEEP PUMP BASIN
W/ 2" PVC DISCHARGE PIPE. TO ORDER: CONTACT THE FOLLOWING ZOELLER PUMPS AUTHORIZED DEALER:
PACIFIC PLUMBING SUPPLY CO.
7115 WEST MARGINAL WAY SW
SEATTLE, WA 98106
206.762.5920
2. 33.4 CUBIC FEET IS REQUIRED FOR THE CONCRETE ANTI -FLOTATION BASE.
3. ELECTRICAL CONTRACTOR TO PROVIDE/RECOMMEND NEMA 4X ALARM PANEL CABINET W/ RED LIGHT AND ALARM PER
MANUFACTURER, 100 DB MIN. PROVIDE EMERGENCY GENERATOR POWER BY TRANS GENERATOR AUTOMATED SYSTEM OR
PORTABLE GENERATOR SYSTEM APPROVED BY OWNER.
4. A BATTERY OPERATED BACKUP POWER SUPPLY FOR THE ALARM SYSTEM IS REQUIRED.
5. CONTROLS SHALL AUTOMATICALLY RESTART AFTER DISRUPTIONS IN POWER SUPPLY.
6. THE SEWER PUMP DISCHARGE LINE SHALL BE PROVIDED WITH AN ACCESSIBLE CHECK VALVE AND GATE VALVE WITHIN THETANK.
7. A 4" CLEANOUT IS REQUIRED ON THE GRAVITY SEWER LINE BETWEEN THE BUILDING AND THE GRINDER PUMP. PROVIDE S'
CLEARANCE BETWEEN HOUSE AND PUMP CHAMBER.
8. USE EXPANSION FITTING TO INCREASE PIPE DISCHARGE LINE TO 2" DIAMETER PRIOR TO EXITING THE PUMP BASIN.
�PUIM�P�BASIN
1 2
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY: _
CITY ENGINEERING DIVISION
C GM
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
tiO GUILL
n C>4a. OTAT4�w.�i'
\ FCC® \�v
Yro '
OVII/22
Q
0
DESIGN: BJL
DRAWN:
ATD
CHECK:
JPU
JOB NO:
21125.20
DATE:
12/03/21
V)
J
Q
W
0
0.
LL I
No
LLI
Ed W 00
N
0 Q
Q
0 Z
<
(n 04
Of ^
D:f
Z
LLI
Y N 0
I--
U I- M
Q
LAJ L0 0
Y LIJ
$
y
SHEET
C4.2
4 CITY OF EDMONDS STANDARD DETAIL
SCALE: PITS