Loading...
BLD2024-0683_Manufacturer_Specifications_and_Installation_Instructions_5.22.2024_1.29.41_PM_427531424SCA4 ComfortTM Series Single -Stage Air Conditioner Carrier with Puron® Refrigerant 1-1/2 To 5 Tons Turn to the experts Product Data This unit has been designed utilizing Carrier's Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. STANDARD FEATURES Industry leading Features / Benefits Efficiency • 13.4 - 16.0 SEER2 (13.5 - 16.5 SEER) / 11.0 — 13.5 EER2 (11.0 - 14.5 EER) • Microtube Technology refrigeration system • Indoor air quality accessories available Reliability • Puron refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Scroll compressor • Internal pressure relief valve • Internal thermal overload • Filter drier Durability WeatherArmofm Protection Package: • Solid, durable sheet metal construction • Dense wire coil guard Applications • Long —line — up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.) • Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits. Features 18 24 30 36 42 48 60 Puron Refrigerant x x x x x x x SEER2 (Range depending on indoor combination) 13.4 - 16.0 13.4 - 16.0 13.4 - 16.0 13.4 - 15.0 13.4 - 15.5 13.4 - 15.2 13.4 - 14.0 Scroll Compressor x x x x x x x Field Installed Filter Drier x x x x x x x Front Seating Service Valves x x x x x x x Internal Pressure Relief Valve x x x x x x x Internal Thermal Overload x x x x x x x Long Line Capability x x x x x x x Low Ambient Capability with Kit x x x x x x x 24SCA4: Product Data Model Number Nomenclature 1 2 3 4 5 6 7 8 9 10 11 12 N N A A A/N N N N A/N A/N A/N N 2 4 S C A 4 1 8 N 0 0 3 Product Series Design Type Tier Major Series SEER2 Cooling Capacity Region Feature Special Feature Voltage 24 = R-410A AC S = Single Stage AC C = Comfort Series A=Initial 4 = 13.4 SEER2 1,000 Btuh (nominal) N = Standard North AC O=Standard O=Standard 3=208/230-1 CATALOG ORDERING NUMBERS PGO eron. Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products, go to —ahridirectcry.org. Physical Data eu A CS Quality ISO 9001 f ere e— UNIT SIZE 18 24 30 36 42 48 60 Compressor Type Scroll REFRIGERANT Puron® (R-41 OA) Control TXV (Puron Hard Shutoff) Factory Charge lb (kg)' 5.5 (2.49) 4.40 (2.00) 6.00 (2.72) 1 5.20 (2.36) 7.90 (3.58) 8.90 (4.04) 9.10 (4.13) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1600 1800 2500 2750 4100 3850 4000 Motor HP 1/12 1/12 1/10 1/5 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 1100 COND COIL Face Area (Sq ft) 8.4 9.8 17.1 12.9 23.6 15.0 19.3 Fins per In. 25 25 25 20 25 20 20 Rows 1 1 1 1 1 2 2 Circuits 3 5 4 5 7 6 9 VALVE CONNECT. (In. ID) Vapor 1 314 3/4 3/4 7/8 7/8 718 7/8 Liquid 3/8" REFRIGERANT TUBES* (In. OD) Rated Vaport 3/4 3/4 314 7/8 7/8 7/8 1-1/8 Rated Liquid Line$ 3/8" *.For 15 ft. lineset f.Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. I. See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. Note: See unit Installation Instruction for proper installation. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data 1:14aa M4amZk9:21:21ZLein 4k, Eel 0:"Im I k rn IEel k,6'I Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron® Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Table 1— Maximum Total Equivalent Length* Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid LineDiam. ne Dia AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit BELOW Indoor Vertical Se partition ft (m) 0-56-10 (0-1.5) (1.83.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-1 5.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 1/4 150 150 125 100 100 75 — — - 18000 3/8 5116 250* 250* 250* 250* 250* 250* 250* 225* 150 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 75 75 75 50 50 -- — — -- 24000 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 1 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- — 30000 3/8 5/16 175 225* 200 175 125 100 75 — -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 36000 3/8 5/16 175 150 150 100 100 100 75 — -- 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 42000 3/8 5116 125 100 100 75 75 50 — — -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 150 48000 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- 60000 3/8 3/8 250* 250* 250* 225* 190 150 110 — *.Maximum actual length not to exceed 200 ft (61 m) t.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Table 2 — Maximum* Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Dlam. w/TXV AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.6) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 1/4 175 250* 250* 250* 250* 250* 250* 250* 18000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 100 125 175 200 225* 250* 250* 250* 24000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- — -- -- -- -- -- 30000 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 36000 3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 42000 318 5/16 175 200 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 48000 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 60000 318 3/8 250* 250* 250* 250* 250* 250* 250* 250* *.Maximum actual length not to exceed 200 ft (61 m) t.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data Table 3 — Refrigerant Charge Adjustments Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft X total length) — (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of lineset* using existing 1/4" liquid line. What charge adjustment is required? Formula:(.27 oz/ft X 15ft) — (9 oz) = (495) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment? Formula:(.40 oz/ft. X 45ft) — (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method. * When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information. Long Line Applications An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. Table 4 — AC with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m) Table 5 — AC with Puron® Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Residential Piping and Long Line Guideline for details Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron® refrigerant: Table 6 — Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1-Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (in. OD) 1/2 Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 1-Stage AC with Puron® 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 1 2 3 5 6 7 8 9 11 18 3/8 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 5/8 0 1 2 2 3 3 4 5 5 24 3/8 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 30 3/8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 8 9 10 12 36 3/8 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 3 4 4 5 6 42 3/8 7/8 0 0 1 1 1 2 2 2 3 11/8 0 0 0 0 0 0 0 0 0 3/4 0 1 2 3 4 5 5 6 7 48 3/8 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 60 3/8 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data ACCESSORIES KIT NUMBER KIT NAME 18 24 30 36 42 48 60 KSAFT0101AAA FRZ THERM KIT X X X X X X X KAATD0101TDR TIME DELAY KIT (90 second TDR) X X X X X X X KAATD0201TDR TIME DELAY KIT (30 second TDR) X X X X X X X KSALA0301410 LOW AMBIENT COOLING KIT X X X X X X X KSALA1001AAA MOTORMASTER KIT X X X X X X X KSAHS2501AAA HARD START KIT X X X X X X X KSACY0101AAA CYCLE PROTR KIT X X X X X X X KSASF0201AAA SPIRT FEET KIT X X X X X X X KAALS0201 LLS* SOL VALVE KIT X X X X X X X KAAWS0101AAA WINTER ST KIT X X X X X X X KAALP0401 PUR LOW PRESSURE SW KIT X X X X X X X KAAH10501PUR HIGH PRESSURE SW KIT X X X X X X X KAACH1701AAA CRKC HTR KIT X X X X KAACH1601AAA CRKC HTR KIT X X X KSATX0201 PUR TXV KIT (For use with copper coils) X X X KSATX0301 PUR TXV KIT (For use with copper coils) X X KSATX0401 PUR TXV KIT (For use with copper coils) X X KSBTX0201 PUR TXV KIT (For use with aluminum coils) X X X KSBTX0301 PUR TXV KIT (For use with aluminum coils) X X KSBTX0401 PUR TXV KIT (For use with aluminum coils) X X KSASH2301COP SOUND BLKT KIT X X X X KSASH2401COP SOUND BLKT KIT X X X X =Accessory Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LOW -AMBIENT COOLING REQUIRED FOR LONG SEA COAST ACCESSORY APPLICATIONS LINE APPLICATIONS APPLICATIONS (Below 55°F/12.8°C) Standard Yes Yes Standard (Within 2 miles/3.22 km) Ball Bearing Fan Motor Standard No Compressor Start Assist Capacitor and Relay Yes Crankcase Heater Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long Line Guideline No MotorMaster@ Control or Yes No No Low -ambient Pressure Switch Winter Start Control I Yest I No I No *.For tubing set lengths between 80 and 200 ft. (24 and 61 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Residential Split -System Long Line Application Guideline. t.Required if Low Pressure Switch is factory or field installed. Accessory Description and Usage (Listed Alphabetically) 1. Ball -Bearing Fan Motor 6. Low -Ambient Pressure Switch Kit A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster® is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 5. Evaporator Freeze Thermostat An SPST temperature -actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 prig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0°F (-18°C) when properly installed and also using wind baffles. Instructions provided in accessory kit. Usage Guideline: A Low -Ambient Pressure Switch or MotorMaster@ Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). 7. MotorMaster® Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to—10°F/-23.3°C), it maintains condensing temperature at 1001F f10°F (37.81C f5.51Q. Usage Guideline: A MotorMaster@ Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. 8. Outdoor Air Temperature Sensor This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for use with compatible Carrier thermostats. 9. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data Accessory Description and Usage (Listed Alphabetically) Continued 10. Support Feet Four or five stick -on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 11. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 12. Time -Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory). When a Time -Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units. 13. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 24SCA4: Product Data AHRI RATINGS For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: www.MyCarrierRatings.com Electrical Data UNIT SIZE V/PH OPER VOLTS COMPR FAN MCA MAX FUSET or CKT BRK AMPS MAX MIN LRA RLA FLA 18 208-230/1 253 197 48.0 8.00 0.40 10.4 15 24 59.5 11.70 0.50 15.1 25 30 64.3 11.80 0.75 15.6 25 36 80.1 12.20 1.05 16.4 25 42 110.2 17.70 1.40 23.5 40 48 124.0 18.50 1.40 24.5 40 60 150.0 25.60 1.52 33.5 50 *.Permissible limits of the voltage range at which the unit will operate satisfactorily t.Time-Delay fuse. FLA- Full Load Amps LRA - Locked Rotor Amps MCA- Minimum Circuit Amps RLA- Rated Load Amps NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1 Sound Power Level without sound shield UNIT SIZE STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) (dB) 125 250 500 1000 2000 4000 8000 18 75 68.9 65.3 65.6 71.4 68.4 63.8 61.2 24 74 66.9 72.6 70.0 70.7 66.6 62.7 59.2 30 73 69.5 68.9 68.9 68.5 62.8 60.0 57.4 36 75 70.8 73.6 71.5 69.5 66.1 63.6 58.1 42 73 73.9 72.6 70.3 68.2 64.3 61.2 57.3 48 76 72.3 74.1 71.2 70.6 63.8 61.6 55.9 60 76 70.0 75.0 71.9 73.7 66.0 61.7 56.3 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Sound Power Level with Accessory sound shield UNIT SIZE STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) (dB) 125 250 500 1000 2000 4000 8000 18 75 66.4 67.0 66.1 71.5 66.6 62.5 61.1 24 74 68.4 72.2 70.4 70.2 66.0 62.3 58.5 30 72 69.3 69.7 68.8 68.0 62.4 59.5 55.7 36 75 71.0 73.7 71.2 69.0 65.4 63.0 57.7 42 73 75.3 71.7 70.0 68.1 63.9 60.2 55.3 48 74 73.3 74.2 71.6 69.9 63.8 60.4 54.7 60 75 70.2 73.9 71.8 72.4 64.2 60.4 54.6 NOTE: Tested in compliance with AHRI 270 but not listed with AHRI. Charging Subcooling (TXV-Type Expansion Device) UNIT SIZE REQUIRED SU 18 1 24 1 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. DIMENSIONS OPERATING SHIPPING SHIPPING SHIPPING UNIT SERIESELECTRICAL A B C D E F G H I K WEIGHT WEIGHT LENGTH HEIGHT CHARACTERISTICS WIDTH . (Sq.) INCH MM INCH MM INCH MM INCH MM NCH MM INCH MM INCH MM NCH MM INCH MM INCH MM NCH MM LbsK s INCH MM INCH MM 24SCA418N'0 0 Y N N N 23 1/8 587.3 25 5/16 642.9 3/4 19.1 4 7/16 113.0 18 1/16 459.0 713/16 197.9 5/16 7.9 3 76.2 11 279.4 10 1/2 266.7 10 1/4 260A 109 49A 26 660.0 30 9/16 775.7 24SCA424N'0 0 Y N N N 25 314 654.0 25 5116 642.4 314 19.1 4 7/16 113.0 21 114 539.9 9 1/8 231.3 5116 7.9 3 76.2 13 112 342.9 13 3302 12 1/2 317.5 121 54.9 28 3/4 730.0 30 9/1624SCA430N'0 0 Y N N N 31 3/16 792.5 32 1/16 815.1 3/4 19.1 6 9/16 166.1 2411/16 626.3 9 118 231.3 5/16 7.9 3 76.2 15 381.0 15 3/4 400.1 16 406.40 161 73.0 34 1/4 870.0 37 W16 947.9 24SCA436N'0 0 Y N N N 31 3/16 792.5 25 5/16 642.4 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 14 1/2 365.3 15 381.0 11 12 292.19 $Lb.K 146 66.2 34 1/4 870.0 30 12 775.2 24SCA442N'0 0 Y N N N 31 3/16 792.5 42 5/16 1074.2 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 118 231.3 5/16 7.9 3 76.2 17 431.8 15 1/2 393.7 22 1/2 571.51 203 92.1 34 1/4 870.0 47 112 1207.1 24SCA448N`0 0 Y N N N 31 3/i6 79.5 2811/16 728.7 7/8 22.2 6 9/16 166.1 2411/16 626.3 9 118 231.3 5116 7.9 3 76.2 14 1/2 368.3 14 1/2 368.3 12 1/2 317.56 1. 86.2 34 1. 870.0 .1.16 .1.6 24SCA460N•0 0 Y N N N 31 3/16 792.5 35 1/2 901.4 7/8 222 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5116 7.9 3 76.2 15 112 393.7 16 406.4 18 1/2 469.92 206 93.4 34 1. 870.0 40 3. 1034.3 '4 W m m Y=YES NOTES: N=N) 1. CENTER OF GRAY rry A so. AIR DISCHARGE ` AIR IN AIR DISCHARGE I F � FIELD POWER SUPPLY CONN. 7/8"(022.2) HOLE WITH AIR IN --AIR IN B 1 1/8"(028.6) KNOCKOUT FIELD CONTROL SUPPLY CON 07/8"($22.2) HOLE ' o E LIQUID LINE000NN. K J 3 3/4" 3 1/2" (96.0) (88.9) H D O CVAPOR LINE CONN. I� Y so. 1 13/16" (46.7) G X S0. (12.7) ¢3/8"(¢9.5) TIEDOWN KNOCKOUTS PLACES" LR 2 13/16(2) (11.0) IN NOTE: ALL DIMENSIONS IN INCH (MM) U.S. ECCN: Not Subject to Regulation (N.S.R.) SD5750-4 REV. A CLEARANCES A Cn D A Clearances (various examples) a Q 0 v v Wall Wall 6" (152.4 mm) ' (609.6) Service 12" (304.8) 24" (609.6) 18" (457.2) ' (304.8) 18" (457.2) U��F1 I 24" (609.6) Service 1213 (304.8) 18" (457.2) 24" Service 52'.4)I 90 12" (304.8) 24" (609.6) Service jj Note: Numbers in () = mm Allow 48" above unit IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. DETAILED COOLING CAPACITIES EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 95 (35) (40.6) 115 (46.1) 125 (51.7) CFM EWB Capacity MBtuh Total Sys. kW** Capacity MBtuh Total Sys. kW** 24SCA418NO030 Capacity MBtuh Total Sys.T"C.p..ItyuCapacity kW**ns# kW** MBtuh Total Sys kW** Capacity MBtuh Total Sys. kW*- Total Sens# Total Sens# Total Outdoor Sens# Total I Sens# Total Sens# 72 (22.2) 21.70 10.46 1.25 20.88 10.18 1.39 19.91 9.85 1.56 18.79 9.48 1.74 17.55 9.08 1.95 16.21 8.64 2.20 67 (19.4) 19.75 12.90 1.25 18.95 12.60 1.40 18.00 12.25 1.56 16.92 11.85 1.74 15.76 11.43 1.96 14.51 10.99 2.22 525 63 (17.2)tt 18.34 12.41 1.25 17.55 12.09 1.40 16.62 11.72 1.56 15.58 11.32 1.75 14.48 10.88 1.97 13.31 10.44 2.23 62 (16.7) 17.96 15.27 1.25 17.19 14.94 1.40 16.29 14.55 1.56 15.40 15.40 1.75 14.54 14.54 1.96 13.62 13.62 2.22 57 (13.9) 17.50 17.50 1.25 16.89 16.89 1.40 16.17 16.17 1.56 15.38 15.38 1.75 14.51 14.51 1.96 13.59 13.59 2.23 72 (22.2) 22.06 11.03 1.28 21.21 10.75 1.43 20.21 10.42 1.59 19.06 10.05 1.77 17.78 9.64 1.99 16.39 9.21 2.24 67 (19.4) 20.10 13.82 1.28 19.27 13.52 1.43 18.30 13.17 1.59 17.20 12.77 1.78 16.00 12.34 1.99 14.71 11.89 2.25 600 63 (17.2)tt 18.69 13.28 1.29 17.87 12.95 1.43 16.92 12.58 1.60 15.85 12.16 1.78 14.70 11.73 2.00 13.50 11.27 2.26 62 (16.7) 18.38 18.38 1.29 17.67 17.67 1.43 16.91 16.91 1.59 16.07 16.07 1.78 15.15 15.15 1.99 14.16 14.16 2.25 57 (13.9) 18.28 18.28 1.29 17.64 17.64 1.43 16.88 16.88 1.59 16.04 16.04 1.78 15.12 15.12 1.99 14.13 14.13 2.25 72 (22.2) 22.31 11.59 1.32 21.44 11.31 1.47 20.41 10.98 1.63 19.23 10.60 1.81 17.93 10.20 2.02 16.51 9.76 2.27 67 (19.4) 20.34 14.72 1.32 19.51 14.42 1.47 18.52 14.06 1.63 17.39 13.66 1.81 16.16 13.23 2.03 14.86 12.76 2.28 675 63 (17.2)tt 18.94 14.11 1.32 18.11 13.79 1.47 17.13 13.41 1.63 16.03 12.99 1.82 14.87 12.54 2.03 13.65 12.05 2.30 62 (16.7) 18.95 18.95 1.32 18.29 18.29 1.47 17.50 17.50 1.63 16.62 16.62 1.81 15.65 15.65 2.03 14.60 14.60 2.28 57 (13.9) 18.93 18.93 1.32 18.26 18.26 1.47 24SCA424NO030 17.48 Outdoor 17.48 1.63 16.59 16.59 1.81 15.62 15.62 2.03 14.58 14.58 2.28 72 (22.2) 27.12 13.79 1.58 26.00 13.38 1.76 24.79 12.92 1.96 23.58 12.43 2.19 22.15 11.88 2.46 20.56 11.27 2.76 67 (19.4) 24.86 16.90 1.59 23.89 16.45 1.77 22.79 15.97 1.97 21.51 15.43 2.20 20.19 14.83 2.48 18.69 14.18 2.79 700 63 (17.2)tt 23.09 16.32 1.59 22.19 15.88 1.77 21.10 15.38 1.98 19.93 14.79 2.22 18.64 14.19 2.49 17.22 13.52 2.80 62 (16.7) 22.57 19.79 1.59 21.76 19.40 1.77 20.76 18.96 1.98 19.56 18.32 2.22 18.39 17.79 2.49 17.32 17.32 2.80 57 (13.9) 22.09 22.09 1.60 21.50 21.50 1.78 20.38 20.38 1.98 19.57 19.57 2.22 18.45 18.45 2.49 17.26 17.26 2.80 72 (22.2) 27.54 14.33 1.62 26.39 13.90 1.80 25.30 13.43 2.00 23.98 12.89 2.24 22.47 12.35 2.50 20.75 11.69 2.80 67 (19.4) 25.37 17.77 1.63 24.34 17.32 1.81 23.20 16.82 2.02 21.80 16.17 2.24 20.50 15.65 2.52 18.97 14.99 2.83 805 63 (17.2)tt 23.58 17.13 1.64 22.58 16.65 1.82 21.52 16.23 2.02 20.09 15.48 2.25 18.94 14.94 2.54 17.47 14.28 2.85 62 (16.7) 23.07 21.03 1.64 22.18 20.62 1.82 21.12 20.11 2.03 19.93 17.98 2.26 19.13 19.13 2.53 17.90 17.90 2.85 57 (13.9) 23.01 23.01 1.64 22.07 22.07 1.82 21.13 21.13 2.03 20.28 20.28 2.26 19.09 19.09 2.54 17.83 17.83 2.84 72 (22.2) 27.81 14.76 1.66 26.65 14.31 1.84 25.58 13.83 2.04 24.30 13.30 2.28 22.68 12.74 2.54 21.00 12.11 2.85 67 (19.4) 25.70 18.49 1.68 24.63 18.03 1.85 23.44 17.51 2.06 22.14 16.94 2.29 20.70 16.35 2.56 19.12 15.69 2.87 900 63 (17.2)tt 23.95 17.84 1.68 22.89 17.33 1.86 21.75 16.80 2.07 20.49 16.21 2.30 19.13 15.58 2.58 17.61 14.90 2.89 62 (16.7) 23.47 22.13 1.68 22.96 21.92 1.86 21.56 21.56 2.07 20.53 20.53 2.29 19.56 19.56 2.57 18.17 18.17 2.87 57 (13.9) 23.63 23.63 1.68 22.77 22.77 1.86 24SCA43ON0030 21.69 Outdoor 1 21.69 2.07 20.71 20.71 2.30 19.56 19.56 2.58 18.18 18.18 2.88 72 (22.2) 34.39 17.38 1.99 32.89 16.86 2.20 31.29 16.31 2.44 29.57 15.72 2.72 27.69 15.09 3.05 25.62 14.41 3.43 67 (19.4) 31.24 21.52 2.00 29.86 20.98 2.21 28.39 20.42 2.45 26.82 19.83 2.73 25.09 19.18 3.06 23.18 18.47 3.44 875 63 (17.2)tt 29.00 20.68 2.01 27.71 20.14 2.22 26.34 19.58 2.46 24.85 18.97 2.74 23.23 18.32 3.07 21.41 17.59 3.46 62 (16.7) 28.48 25.54 2.01 27.24 24.97 2.22 25.99 25.99 2.46 24.73 24.73 2.76 23.45 23.45 3.07 21.92 21.92 3.54 57 (13.9) 27.96 27.96 2.01 26.96 26.96 2.22 25.89 25.89 2.46 24.71 24.71 2.75 23.41 23.41 3.07 21.95 21.95 3.45 72 (22.2) 34.92 18.35 2.05 33.36 17.82 2.25 31.70 17.27 2.49 29.96 16.72 2.79 27.97 16.03 3.11 25.83 15.34 3.49 67 (19.4) 31.76 23.06 2.06 30.32 22.52 2.26 28.80 21.95 2.50 27.22 21.35 2.80 25.39 20.68 3.12 23.43 19.96 3.50 1000 63 (17.2)tt 29.51 22.12 2.07 28.16 21.56 2.27 26.74 20.99 2.51 25.19 20.35 2.82 23.52 19.70 3.13 21.69 18.97 3.51 62 (16.7) 29.20 29.20 2.07 28.12 28.12 2.27 26.96 26.96 2.51 25.70 25.70 2.79 24.31 24.31 3.12 22.75 22.75 3.50 57 (13.9) 29.16 29.16 2.07 28.07 28.07 2.27 26.92 26.92 2.51 25.67 25.67 2.80 24.27 24.27 3.12 22.72 22.72 3.50 72 (22.2) 35.29 19.30 2.10 33.68 18.77 2.31 31.97 18.21 2.55 30.14 17.61 2.83 28.14 16.96 3.16 25.95 16.25 3.54 67 (19.4) 32.14 24.57 2.12 30.66 24.01 2.32 29.10 23.43 2.56 27.45 22.81 2.85 25.61 22.13 3.17 23.66 21.36 3.57 1125 63 (17.2)tt 29.88 23.51 2.13 28.49 22.95 2.33 27.03 22.36 2.57 25.46 21.73 2.85 23.75 21.03 3.18 21.90 20.22 3.56 62 (16.7) 30.19 30.19 2.12 29.04 29.04 2.33 27.81 27.81 2.57 26.50 26.50 2.86 25.01 25.01 3.18 23.37 23.37 3.55 57 (13.9) 30.14 30.14 2.12 29.00 29.00 2.33 27.77 27.77 2.57 26.46 26.46 2.85 24.98 24.98 3.18 23.34 23.34 3.55 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES °F CC) EVAPORATOR AIR 75 (23.9) 85 (29.4) 95 (35) (40.6) 115 (46.1) 125 (51.7) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. kW** 24SCA436NO030 Capacity MBtuh Total Sys.T"C.p..Ityuh kW**ns# Total Sys kW** Capacity MBtuh Total Sys kW** Capacity MBtuh Total Sys. kW*- Total Sens# Total Outdoor Sens# Total Sens# Total Sens# 72 (22.2) 40.69 19.90 2.41 38.81 19.27 2.66 36.90 18.55 2.93 34.80 17.74 3.24 32.32 16.95 3.61 29.76 16.06 4.05 67 (19.4) 37.24 24.64 2.42 35.72 23.66 2.67 33.80 23.24 2.94 31.87 22.38 3.25 29.66 21.55 3.61 27.24 20.62 4.06 1090 63 (17.2)tt 34.67 23.82 2.41 33.26 23.01 2.67 31.46 22.47 2.94 29.62 21.58 3.25 27.60 20.72 3.61 25.33 19.76 4.04 62 (16.7) 34.01 29.13 2.41 32.44 28.47 2.67 30.82 27.76 2.94 29.10 27.01 3.25 27.71 27.71 3.61 25.82 25.82 4.05 57 (13.9) 33.39 33.39 2.41 32.23 32.23 2.67 30.78 30.78 2.94 29.37 29.37 3.25 27.60 27.60 3.60 25.78 25.78 4.05 72 (22.2) 41.15 20.46 2.46 39.22 19.82 2.71 37.24 19.05 2.98 35.04 18.27 3.29 32.56 17.45 3.66 29.93 16.53 4.10 67 (19.4) 37.72 25.54 2.46 36.08 24.90 2.72 34.15 24.09 2.99 32.09 23.27 3.30 29.90 22.38 3.66 27.42 21.47 4.10 1200 63 (17.2)tt 35.02 23.92 2.47 33.56 23.97 2.72 31.80 23.19 2.99 29.92 22.39 3.30 27.84 21.51 3.66 25.50 20.53 4.10 62 (16.7) 34.48 30.45 2.47 32.90 29.75 2.72 31.91 29.92 2.99 30.06 30.06 3.30 28.26 28.26 3.66 26.48 26.48 4.10 57 (13.9) 34.26 34.26 2.47 33.05 33.05 2.72 31.54 31.54 2.99 30.03 30.03 3.30 28.25 28.25 3.67 26.28 26.28 4.10 72 (22.2) 41.63 21.14 2.52 39.74 20.44 2.78 37.66 19.72 3.05 35.34 18.92 3.36 32.83 18.06 3.73 30.09 17.10 4.17 67 (19.4) 38.24 26.68 2.53 36.46 25.96 2.78 34.51 25.20 3.06 32.34 24.42 3.37 30.09 23.49 3.73 27.57 22.55 4.17 1350 63 (17.2)tt 35.61 25.70 2.53 33.97 25.00 2.79 32.14 24.21 3.06 30.10 23.35 3.36 28.07 22.60 3.73 25.65 21.51 4.16 62 (16.7) 36.30 29.92 2.54 34.32 32.06 2.79 32.34 32.34 3.06 30.75 30.75 3.37 28.95 28.95 3.73 26.86 26.86 4.17 57 (13.9) 35.27 35.27 2.53 33.95 33.95 2.79 32.44 •• • Outdoor 1 32.44 3.06 30.72 1 30.72 3.37 28.85 28.85 3.73 26.83 26.83 4.17 72 (22.2) 46.39 23.82 2.89 44.31 23.00 3.17 42.29 22.15 3.47 40.04 21.26 3.82 37.65 20.36 4.21 35.07 19.31 4.64 67 (19.4) 42.01 28.83 2.89 40.38 28.12 3.16 38.40 27.16 3.47 36.33 26.24 3.81 34.14 25.28 4.20 31.79 24.24 4.64 1225 63 (17.2)tt 38.81 27.78 2.89 37.18 26.96 3.16 35.44 26.12 3.46 33.55 25.22 3.81 31.50 24.24 4.19 29.30 23.18 4.62 62 (16.7) 38.00 33.69 2.89 36.43 32.85 3.16 34.78 32.08 3.46 32.89 31.10 3.80 30.92 30.17 4.19 29.16 29.16 4.62 57 (13.9) 36.62 36.62 2.89 35.50 35.50 3.16 34.20 34.20 3.46 32.74 32.74 3.80 31.07 31.07 4.19 29.26 29.26 4.62 72 (22.2) 47.19 24.61 2.97 45.21 23.77 3.24 43.00 22.90 3.55 40.67 21.99 3.90 38.13 21.02 4.29 35.43 19.99 4.72 67 (19.4) 42.84 30.07 2.97 40.94 29.23 3.24 39.00 28.34 3.55 36.87 27.42 3.89 34.60 26.43 4.28 32.13 25.38 4.71 1380 63 (17.2)tt 39.55 28.93 2.97 37.86 28.10 3.24 36.04 27.39 3.54 34.06 26.28 3.88 31.94 25.30 4.27 29.63 24.25 4.70 62 (16.7) 38.77 35.39 2.96 37.09 34.54 3.23 35.35 33.69 3.54 33.87 30.17 3.89 31.31 32.28 4.26 30.14 30.14 4.72 57 (13.9) 37.87 37.87 2.96 36.72 36.72 3.23 35.32 35.32 3.54 33.71 33.71 3.88 32.00 32.00 4.28 29.94 29.94 4.66 72 (22.2) 48.16 25.44 3.06 45.96 24.63 3.34 43.73 23.76 3.65 41.29 22.81 3.99 38.61 21.81 4.38 35.78 20.70 4.82 67 (19.4) 43.67 31.54 3.06 41.70 30.65 3.33 39.63 29.77 3.64 37.39 28.81 3.98 35.02 27.80 4.38 32.47 26.73 4.81 1575 63 (17.2)tt 40.32 30.30 3.06 38.53 29.42 3.33 36.60 28.54 3.63 34.54 27.57 3.98 32.33 26.53 4.35 29.94 25.45 4.80 62 (16.7) 39.54 37.49 3.06 37.80 36.67 3.33 36.70 35.79 3.63 34.71 34.71 3.98 32.91 32.91 4.36 30.96 30.96 4.80 57 (13.9) 39.24 39.24 3.06 38.00 38.00 3.33 24SCA448NO030 36.36 Outdoor 36.36 3.63 34.72 34.72 3.98 32.80 32.80 4.36 30.90 30.90 4.80 72 (22.2) 54.25 27.28 3.40 51.97 26.48 3.71 49.55 25.64 4.08 46.97 24.75 4.50 44.19 23.81 4.97 41.16 22.81 5.50 67 (19.4) 49.34 33.66 3.39 47.24 32.84 3.70 45.01 31.98 4.06 42.64 31.08 4.48 40.14 30.09 4.95 37.32 29.08 5.47 1400 63 (17.2)tt 45.82 32.37 3.39 43.85 31.54 3.69 41.76 30.68 4.05 39.55 29.76 4.46 37.16 28.79 4.93 34.57 27.75 5.45 62 (16.7) 45.10 39.88 3.38 43.21 39.02 3.69 41.23 38.08 4.05 39.25 39.25 4.46 37.33 37.33 4.93 35.21 35.21 5.46 57 (13.9) 44.11 44.11 3.38 42.58 42.58 3.69 40.95 40.95 4.05 39.19 39.19 4.46 37.23 37.23 4.93 35.15 35.15 5.46 72(22.2) 54.89 28.36 3.47 52.54 27.56 3.78 50.05 26.71 4.15 47.40 25.81 4.57 44.55 24.86 5.05 41.45 23.84 5.57 67 (19.4) 49.97 35.37 3.46 47.80 34.54 3.77 45.50 33.67 4.14 43.10 32.76 4.55 40.48 31.78 5.02 37.65 30.72 5.55 1545 63 (17.2)tt 46.43 33.96 3.46 44.39 33.12 3.76 42.25 32.25 4.12 39.98 31.32 4.54 37.53 30.33 5.00 34.88 29.26 5.53 62 (16.7) 45.90 42.13 3.46 44.13 40.89 3.76 42.23 42.23 4.12 40.37 40.37 4.54 38.35 38.35 5.01 36.12 36.12 5.54 57 (13.9) 45.51 45.51 3.45 43.89 43.89 3.76 42.17 42.17 4.12 40.32 40.32 4.54 38.30 38.30 5.01 36.08 36.08 5.53 72 (22.2) 55.69 30.18 3.59 53.24 29.36 3.91 50.66 28.50 4.28 47.90 27.59 4.70 44.95 26.62 5.17 41.75 25.59 5.70 67 (19.4) 50.78 38.29 3.58 48.53 37.44 3.90 46.16 36.55 4.26 43.68 35.62 4.68 40.98 34.60 5.15 38.09 33.48 5.67 1800 63 (17.2)tt 47.22 36.66 3.58 45.11 35.80 3.89 42.89 34.90 4.25 40.54 33.94 4.66 38.03 32.91 5.13 35.33 31.77 5.65 62 (16.7) 47.61 47.61 3.58 45.85 45.85 3.89 43.99 43.99 4.25 41.98 41.98 4.67 39.82 39.82 5.14 37.43 37.43 5.67 57 (13.9) 47.54 47.54 3.58 45.79 45.79 3.89 43.93 43.93 4.25 41.93 41.93 4.67 39.76 39.76 5.14 37.38 37.38 5.67 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES °F CC) EVAPORATOR AIR 75 (23.9) 85 (29.4) 95 (35) (40.6) 115 (46.1) 125 (51.7) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. kW** 24SCA46ON0030 Capacity MBtuh Total Sys.T"C.p..Ity kW**ns# Total Sys kW** Capacity MBtuh Total Sys kW** Capacity MBtuh Total Sys. kW*- Total Sens# Total Outdoor Sens# Total Sens# Total Sens# 72 (22.2) 67.31 34.72 4.23 64.05 33.52 4.62 60.65 32.23 5.08 57.21 30.87 5.60 53.30 29.42 6.18 49.09 27.91 6.83 67 (19.4) 61.11 42.71 4.20 58.80 41.29 4.60 55.50 40.17 5.05 52.26 38.78 5.56 48.75 37.20 6.15 44.88 35.62 6.80 1800 63 (17.2)tt 56.68 41.19 4.18 54.40 39.82 4.57 51.47 38.70 5.02 48.47 37.27 5.53 45.19 35.74 6.11 41.62 34.01 6.76 62 (16.7) 55.62 50.35 4.18 53.08 49.09 4.56 50.52 47.91 5.01 48.10 44.25 5.53 45.71 45.84 6.12 42.28 42.28 6.77 57 (13.9) 54.39 54.39 4.17 52.57 52.57 4.56 50.12 50.12 5.01 47.19 47.19 5.51 45.17 45.17 6.11 42.19 42.19 6.77 72 (22.2) 68.24 35.82 4.32 64.89 34.59 4.72 61.59 33.27 5.18 58.04 31.85 5.70 53.80 30.40 6.28 49.46 28.73 6.93 67 (19.4) 62.05 44.42 4.30 59.30 43.20 4.70 56.18 41.84 5.15 52.79 40.37 5.66 49.21 38.84 6.25 45.24 37.14 6.90 2000 63 (17.2)tt 57.57 42.78 4.28 55.01 41.58 4.67 52.14 40.25 5.12 49.05 38.77 5.63 45.57 37.20 6.21 41.97 35.50 6.87 62 (16.7) 56.53 52.71 4.28 53.95 51.52 4.67 51.65 51.12 5.12 49.59 49.78 5.64 46.26 46.26 6.23 43.14 43.14 6.88 57 (13.9) 56.01 56.01 4.28 54.04 54.04 4.67 51.66 51.66 5.12 49.06 49.06 5.64 46.24 46.24 6.22 43.14 43.14 6.88 72 (22.2) 69.18 37.06 4.45 65.68 35.81 4.84 62.30 34.45 5.30 58.62 32.97 5.82 54.40 31.51 6.41 49.78 29.76 7.06 67 (19.4) 63.10 46.47 4.43 60.12 45.28 4.82 56.89 43.78 5.27 53.36 42.31 5.79 49.61 40.75 6.37 45.50 38.87 7.02 2250 63 (17.2)tt 58.44 44.65 4.41 55.77 43.41 4.80 52.78 42.04 5.24 49.56 40.56 5.76 46.04 38.93 6.34 42.20 37.06 6.99 62 (16.7) 57.39 55.65 4.40 55.86 54.50 4.80 52.98 52.98 5.25 50.47 50.47 5.77 47.44 47.44 6.36 44.15 44.15 7.01 57 (13.9) 57.74 57.74 4.41 55.59 55.59 4.80 53.12 53.12 5.25 50.41 50.41 5.77 47.36 47.36 6.35 44.11 44.11 7.01 t Total and sensible capacities are net capacities based on 25 feet line set at DOE Appendix Ml test levels. t Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80°F (27°C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2023. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation incapacity may occur. ** System kw is total of indoor and outdoor unit kilowatts. tt At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB - Entering Wet Bulb 24SCA4: Product Data CONDENSER ONLY RATINGS SST °F (-C) 30.0 (-1.1) 35.0 (1.7) 40.0 (4.4) 45.0 (7.2) 50.0 (10.0) 55.0 (12.8) 30.0 35.0 (1.7) 40.0 (4.4) 45.0 (7.2) 50.0 (10.0) 55.0 (12.8) 30.0 (-1.1) 35.0 (1.7) 40.0 (4.4) 45.0 (7.2) 50.0 (10.0) 55.0 (12.8) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55.0 (12.8) 65.0 (18.3) 75.0 (23.9) 24SCA418NO030 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) TCG 15.10 14.10 13.10 12.20 11.30 10.40 9.50 SDT 70.40 79.80 89.20 98.70 108.30 117.80 127.30 KW 0.80 0.91 1.02 1.15 1.30 1.46 1.65 TCG 16.60 15.60 14.60 13.60 12.70 11.70 10.60 SDT 71.50 80.80 90.30 99.70 109.20 118.70 128.20 KW 0.80 0.91 1.02 1.15 1.30 1.47 1.66 TCG 18.30 17.20 16.10 15.10 14.10 13.00 11.90 SDT 72.50 81.90 91.30 100.80 110.20 119.60 129.10 KW 0.79 0.90 1.02 1.15 1.30 1.47 1.66 TCG 20.00 18.80 17.80 16.70 15.60 14.50 13.30 SDT 73.70 83.00 92.40 101.90 111.20 120.70 130.10 KW 0.78 0.89 1.02 1.15 1.30 1.47 1.67 TCG 21.80 20.70 19.50 18.40 17.30 16.10 14.80 SDT 74.90 84.20 93.50 103.00 112.40 121.70 131.10 KW 0.77 0.89 1.01 1.15 1.30 1.48 1.67 TCG 23.80 22.60 21.40 20.20 19.00 17.70 16.40 SDT 76.10 85.40 94.80 104.20 113.60 122.90 132.10 KW 0.76 0.88 1.00 24SCA424NO030 1.15 1.30 1.48 1.68 TCG 19.34 18.30 17.26 16.17 15.01 13.77 12.40 SDT 73.94 83.52 93.16 102.71 112.14 121.57 130.96 KW 0.98 1.12 1.29 1.47 1.68 1.92 2.20 TCG 21.38 20.26 19.13 17.96 16.72 15.37 13.93 SDT 75.24 84.81 94.38 103.89 113.31 122.73 132.06 KW 0.98 1.13 1.29 1.47 1.68 1.92 2.20 TCG 23.58 22.37 21.16 19.90 18.57 17.13 15.58 SDT 76.62 86.14 95.61 105.11 114.51 123.92 133.17 KW 0.98 1.13 1.29 1.47 1.68 1.92 2.20 TCG 25.95 24.65 23.35 22.00 20.56 19.03 17.39 SDT 78.08 87.51 96.97 106.34 115.79 125.11 134.39 KW 0.98 1.13 1.29 1.47 1.68 1.92 2.19 TCG 28.48 27.09 25.69 24.26 22.72 21.08 19.32 SDT 79.73 89.10 98.46 107.57 116.94 126.28 135.58 KW 0.98 1.13 1.28 1.46 1.67 1.91 2.19 TCG 31.22 29.72 28.21 26.66 25.02 23.26 21.38 SDT 81.37 90.71 100.00 109.14 118.21 127.54 136.81 KW 0.98 1.12 1.28 24SCA43ON0030 1.45 1.65 1.89 2.17 TCG 23.36 22.09 20.86 19.60 18.26 16.80 15.18 SDT 77.76 87.66 97.65 107.75 117.95 128.31 138.89 KW 1.20 1.35 1.53 1.74 1.99 2.28 2.64 TCG 25.77 24.41 23.07 21.70 20.25 18.65 16.96 SDT 79.48 89.29 99.26 109.32 119.51 129.88 140.34 KW 1.21 1.36 1.54 1.75 2.01 2.31 2.67 TCG 28.37 26.91 25.46 23.98 22.39 20.67 18.83 SDT 81.25 91.02 100.97 110.97 121.09 131.37 141.69 KW 1.22 1.37 1.55 1.77 2.02 2.33 2.69 TCG 31.18 29.61 28.04 26.43 24.70 22.83 20.81 SDT 83.07 92.90 102.76 112.64 122.70 132.94 143.15 KW 1.23 1.38 1.56 1.78 2.04 2.35 2.72 TCG 34.21 32.51 30.81 29.05 27.19 25.16 22.98 SDT 85.18 94.87 104.65 114.51 124.32 134.42 144.49 KW 1.24 1.39 1.57 1.80 2.06 2.37 2.74 TCG 37.46 35.63 33.78 31.87 29.86 27.66 25.32 SDT 87.34 96.88 106.60 116.34 125.94 135.92 145.81 KW 1.24 1.40 1.58 1.81 2.07 2.39 2.75 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15 24SCA4: Product Data CONDENSER ONLY RATINGS (Continued) SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55.0 (12.8) 65.0 (18.3) 75.0 (23.9) 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) 24SCA436NO030 TCG 30.00 28.36 26.78 25.19 23.53 21.80 19.97 30.0 SDT 75.41 84.88 94.32 103.73 113.17 122.50 131.71 KW 1.39 1.66 1.90 2.14 2.39 2.66 2.98 TCG 33.10 31.32 29.60 27.86 26.04 24.12 22.12 35.0 SDT 76.81 86.28 95.69 105.00 114.37 123.69 132.82 (1 KW 1.41 1.68 1.92 2.16 2.41 2.70 3.03 TCG 36.40 34.50 32.61 30.66 28.71 26.61 24.41 40.0 SDT 78.36 87.68 97.07 106.39 115.63 124.86 133.91 (4.4) KW 1.43 1.69 1.93 2.17 2.43 2.73 3.07 TCG 39.90 37.87 35.82 33.74 31.53 29.24 26.79 45.0 SDT 80.19 89.25 98.51 107.73 116.97 126.07 135.21 (7.2) KW 1.46 1.70 1.94 2.18 2.45 2.75 3.12 TCG 43.65 41.42 39.21 36.90 34.51 32.00 29.36 50.0 SDT 81.93 91.11 99.94 109.21 118.32 127.31 136.24 (10.0) KW 1.47 1.72 1.94 2.19 2.46 2.77 3.14 TCG 47.55 45.19 42.78 40.26 37.63 34.90 32.03 55.0 SDT 84.02 92.82 101.95 110.58 119.68 128.54 137.29 (12.8) KW 1.48 1.72 1.95 2.19 2.47 2.78 3.15 24SCA442NO030 TCG 33.37 31.78 30.15 28.45 26.69 24.84 22.89 30.0 SDT 69.65 79.17 88.69 98.22 107.73 117.17 126.59 KW 1.86 2.07 2.31 2.58 2.87 3.21 3.58 TCG 36.81 35.06 33.26 31.40 29.46 27.44 25.34 35.0 SDT 70.90 80.29 89.76 99.21 108.68 118.11 127.43 (1 KW 1.87 2.08 2.32 2.59 2.89 3.22 3.60 TCG 40.55 38.61 36.62 34.56 32.45 30.26 27.97 40.0 SDT 72.12 81.47 90.89 100.36 109.73 119.04 128.37 (4.4) KW 1.88 2.09 2.33 2.60 2.90 3.24 3.62 TCG 44.61 42.45 40.25 37.99 35.72 33.31 30.81 45.0 SDT 73.45 82.79 92.17 101.54 110.71 120.07 129.36 (7.2) KW 1.88 2.10 2.34 2.61 2.91 3.26 3.64 TCG 49.00 46.61 44.20 41.72 39.18 36.60 33.89 50.0 SDT 74.85 84.11 93.40 102.71 112.06 121.16 130.34 (10.0) KW 1.89 2.10 2.35 2.62 2.93 3.27 3.66 TCG 53.74 51.14 48.46 45.75 42.97 40.14 37.20 55. 2.08) SDT 76.40 85.41 94.76 104.00 113.27 122.31 131.40 0 KW 1.89 2.11 2.35 2.63 2.94 3.29 3.68 24SCA448NO030 TCG 38.05 36.11 34.19 32.26 30.26 28.17 25.97 30.0 SDT 70.62 79.92 89.27 98.66 108.06 117.49 126.92 KW 2.25 2.45 2.70 3.00 3.34 3.75 4.21 TCG 41.87 39.78 37.70 35.60 33.43 31.17 28.79 35.0 SDT 72.00 81.22 90.51 99.85 109.22 118.60 127.96 (1 KW 2.26 2.46 2.72 3.02 3.37 3.77 4.24 TCG 46.02 43.75 41.49 39.20 36.85 34.40 31.71 40.0 SDT 73.48 82.63 91.89 101.17 110.47 119.77 129.03 (4.4) KW 2.26 2.47 2.73 3.04 3.39 3.80 4.27 TCG 50.50 48.04 45.58 43.10 40.54 37.88 35.10 45.0 SDT 75.10 84.21 93.39 102.59 111.81 121.04 130.22 (7.2) KW 2.27 2.48 2.75 3.06 3.42 3.83 4.30 TCG 55.39 52.67 50.00 47.30 44.52 41.64 38.62 50.0 SDT 76.95 85.90 94.99 104.12 113.25 122.35 131.43 (10.0) KW 2.27 2.49 2.76 3.08 3.45 3.86 4.34 TCG 60.58 57.73 54.77 51.83 48.81 45.68 42.41 55.0 SDT 78.82 87.79 96.72 105.73 114.73 123.74 132.72 (12.8) KW 2.27 2.51 2.78 3.10 3.47 3.89 4.37 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 24SCA4: Product Data CONDENSER ONLY RATINGS (Continued) SST °F (°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55.0 (12.8) 65.0 (18.3) 75.0 (23.9) 24SCA46ON0030 85.0 (29.4) 95.0 (35.0) 105.0 (40.6) 115.0 (46.1) TCG 48.86 46.38 43.92 41.41 38.79 36.02 33.09 30.0 SDT 71.15 80.38 89.65 98.97 108.25 117.49 126.66 KW 2.73 2.99 3.30 3.67 4.10 4.59 5.16 TCG 53.79 51.10 48.43 45.70 42.85 39.87 36.67 35.0 SDT 72.64 81.80 91.01 100.26 109.46 118.64 127.76 (1 KW 2.75 3.01 3.33 3.70 4.14 4.64 5.21 TCG 59.10 56.19 53.28 50.30 47.20 43.95 40.47 40.0 SDT 74.25 83.34 92.49 101.64 110.78 119.88 128.91 (4.4) KW 2.77 3.04 3.36 3.74 4.18 4.69 5.27 TCG 64.80 61.64 58.47 55.23 51.85 48.30 44.54 45.0 SDT 75.99 84.99 94.06 103.14 112.20 121.20 130.14 (7.2) KW 2.78 3.06 3.39 3.78 4.23 4.74 5.32 TCG 70.91 67.48 64.02 60.48 56.80 52.92 48.82 50.0 SDT 77.86 86.77 95.77 104.76 113.70 122.61 131.43 (10.0) KW 2.79 3.08 3.42 3.81 4.27 4.79 5.37 TCG 77.45 73.70 69.92 66.05 62.03 57.81 53.36 55.0 SDT 79.90 88.70 97.59 106.47 115.30 124.08 132.77 (12.8) KW 2.81 3.10 3.44 3.85 4.31 4.83 5.42 KW - Outdoor Unit Kilowatts Only. SDT -Saturated Temperature Leaving Compressor (°F) SST -Saturated Temperature Entering Compressor (°F/°C) TCG -Gross Cooling Capacity (1000 Btuh) KW - Outdoor Unit Kilowatts Only. SDT -Saturated Temperature Leaving Compressor (°F) SST -Saturated Temperature Entering Compressor (°F/°C) TCG -Gross Cooling Capacity (1000 Btuh) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 24SCA4: Product Data GUIDE SPECIFICATIONS GENERAL System Description Outdoor -mounted, air-cooled, split -system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210/240. — Unit will be certified for capacity and efficiency, and listed in AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 470 psig. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron@ (R-410A), and special features required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Fans — Condenser fan will be direct -drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Air-cooled, split -system air conditioner 24SCA4 1-1/2 to 5 nominal tons Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed. Refrigeration Com op nents — Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of Puron (R-410A) refrigerant, and compressor oil. — Unit will be shipped with filter drier for Puron (R-410A) refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °FPC wet bulb and °FPC dry bulb, and air entering the unit at °F/°C. — The system will have a SEER2 of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Nominal unit electrical characteristics will be v, three phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. C 2022 Carrier. All rights reserved. Edition Date: 06/22 7Catalog No: 24SCA4-01PD Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18