REVIEWED BLD2024-0170+Manufacturer_Specifications_and_Installation_Instructions+2.7.2024_1.14.11_PM+4045921VRF Outdoor Unit BLD2024-0170 RECEIVED �rrie 38VMA144RDL5-1 - Heat RecoveryFeb 2024 CITY OFFEDMONDS DEVELOPMENT SERVICES DEPARTMENT Job Data Buyer Unit Number Performance Data Certified By Submittal Data Buyer PO # Z REVIEWED BY CITY OF EDMONDS Location Carrier # Model Number Date Heat Recovery Features Modules available from 6 to 28 tons Modules have inverter -driven scroll compressors Direct -drive, inverter -driven outdoor motor Up to 3280 ft (1000 m) actual total system piping (liquid line) 656 ft (200 m) actual piping length from outdoor unit to furthest fan coil Up to 3937 ft (1200 m) control wiring between the outdoor units and indoor units Header Unit Model 38VMA144RDL5-1 PERFORMANCE Nominal Cooling Capacity Btu/h 142,800 Nominal Heating Capacity Btu/h 160,000 Maximum Total Connected Indoor Unit Capacity 50% to 150% SIMULTANEOUS COOLING AND HEATING EFFICIENCYt SCHE, Ducted FCUs 26.50 SCHE, Ductless FCUs 26.50 COOLING EFFICIENCYt EER/IEER, Ducted FCUs Btu/Wh 12.30/24.00 Power Consumption, Ducted FCUs kW 10.60 EER/IEER, Ductless FCUs Btu/Wh 13.00/24.40 Power Consumption, Ductless FCUs kW 9.00 HEATING EFFICIENCYt COP at 47°F, Ducted FCUs 3.60 Power Consumption, Ducted FCUs kW 11.80 COP at 47°F, Ductless FCUs 3.98 Power Consumption, Ductless FCUs kW 9.60 Fan Type (Qty) Propeller (2) Airflow, Standard Range CFM 10,100 Sound Pressure dBA 63.3 External Static Pressure" I in. wg 1 0.24 LEGEND db — Dry Bulb COP — Coefficient of Performance EER — Energy Efficiency Ratio FCU — Fan Coil Unit IEER — Integrated Energy Efficiency Ratio wb — Wet Bulb SCHE — Simultaneous Cooling and Heating Efficiency • Operating temperature range Cooling (db): 50 to 1250F (-150 to 520C) Heating (wb): —130 to 640F (-251 to 18°C) • Protection: high pressure sensor and switch, low pressure sensor and switch, process controller board fuse, inverter overload protection • 7-year compressor limited warranty • 5-year parts limited warranty ELECTRICAL Power Supply V/P / Hz 208-230/3/60 Minimum Circuit Amps (MCA) A 70 Recommended Fuse Size A 80 COMPRESSORS Type (Number) Inverter Hermetic Scroll (1) FAN MOTOR Motor Type (Steps) Inverter Direct Driven (13) Motor Output kW 2 x 0.26 PHYSICAL DATA Pipe Connection Size - Liquid (High Pressure) in. 7/8 (Brazed) Pipe Connection Size - Gas (Low Pressure) in. 1-1/8 (Brazed) Refrigerant R-410A Factory Chargett lb 44.2 Unit Width in. 78-3/8 Unit Height in. 64-3/8 Unit Depth in. 31-1/8 Net Weight lb 1137 tRated per AHRI (Air -Conditioning, Heating and Refrigeration Institute) 1230 Standard. Cooling: Indoor 80°F (27°C) db/67°F (20°C) wb; Outdoor 95°F (35°C) db Heating: Indoor 70°F (21 °C) db; Outdoor 47°F (8°C) db/43°F (6°C) wb *Requires setting by menu functions. ttAdditional charge required. NOTE: Unit cabinet and coil slab shall be capable of withstanding 500-hour salt spray test. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 38VMR1445L-C-2SD Pg 1 08-18 Replaces: 38VMR14451_-C-1SD C DIMENSIONAL DRAWING OUTDOOR UNIT 38VMA144RDL5-1 US © Carrier Corporation 2018 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 38VMR1445L-C-2SD Pg 2 08-18 Replaces: 38VMR1445L-C-1SD VRF Multiport Distribution Controller (MDC) , 40VMD006M--3 — Main MDC Job Data Buyer Unit Number Performance Data Certified By Submittal Data Location Buyer PO # Model Number .. ►- MDC UNIT MODEL 40VMD006M--3 NUMBER OF PORTS 6 MAX CAPACITY PER kBtu/h 54 INDOOR UNIT PORT AVAILABLE SUB MDC 40VMD006S 3 MODELS' ELECTRICAL Power Supply V-Ph-Hz 208/230-1-60 Minimum Circuit A 0.73 Amps Maximum Overcurrent A 15 Protection Motor Type DC Sized per NEC and local Power Wiring codes based on nameplate electrical data Signal Wiring 2-core shielded twisted pair cable 20 AWG - 16 AWG DESIGN PRESSURE, HIGH/LOW psig 480/320 DRAINAGE WATER in. 1 PIPE DIAMETER, OD PIPE SIZE - ODU TO MAIN MDC High Pressure (Mixed in Phase) Low Pressure (Gas) in. 3/4 - 1 3/1 Carrier # Date STANDARD FEATURES • Allows the connection of multiple indoor units to the Heat Recovery VRF system • MDC allows up to 6 indoor unit connections • Main MDCs have refrigerant ports that feed sub MDCs (if used) • Heat Recovery VRF System can support 1 Main MDC and 2 sub MDCs, maximum • Separate 208-230/1/60 power required • MDC ports may be twinned to serve high -capacity units (sizes greater than 54 kBtu/h) • MDC has individual "home run" communication port plugs for each indoor unit • Liquid and gas pipe adapters are provided with MDCs to accommodate various indoor unit capacities • High-pressure, low-pressure, and gas pipe adapters are provided with Sub MDCs to accommodate various MDC total capacities PIPE SIZE - MAIN MDC TO SUB MDC High Pressure (Gas) in. 5/3 - 7/e Low Pressure (Gas) in. 3/4 - 1 '/1 Liquid in. 3/8 5/g PIPE SIZE - MAIN MDC TO IDU Liquid in. 1/4 3/1 Gas in. 1/2 - 7/3 PHYSICAL DATA Refrigerant R-410A Unit Dimensions (WxHxD) in. 37 x 12 7/8 x 22 5/8 Packing Dimensions (WxHxD) in. 441/2 x 18 x 331/8 Net Weight lb 132 LEGEND AWG — American Wire Gage IDU — Indoor Unit MDC — Multiport Distribution Controller NEC — National Electrical Code ODU — Outdoor Unit Number of sub MDC ports cannot exceed the number of main MDC ports. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VMD006M-C-1SD Pg 1 10-16 Replaces: New DIMENSIONAL DRAWING MAIN MDC 40VMD006M--3 Connection pipe of (Note 1) indoor unit (Gas) 3 2 Connection pipe of l p I indoor unit (Liquid) 6 5 4 3 2 1 Detail of X Section Connection pipe of sub MDC (High pressure) 4-3/4 Connection pipe of sub MDC (Low Pressure) Connection pipe of sub MDC (Liquid) Drain pipe (O D (25 4]) 6-3/8 Connection pipe of outdoor unit (Low pressure) / Connection pipe of outdoor unit (Hioh pressure) NOTES: 1. An indoor unit must be connected to port #1 to avoid communication error. 2. Optional condensate connection is available on either side of the unit. 3. Refer to installation manual for piping sizes. 4. All dimensions shown in inches [mm]. v Cond—te Drain Drain pan Clamp connectionconnaction m -5/8[40] 9/16[14] Outlet 13/16[20] Detail of Y Section Detail of Z Section MODEL MDC006 A 37 in. B 33 7/8 in. © Carrier Corporation 2016 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VMD006M-C-1 SD Pg 2 10-16 Replaces: New VRF Indoor Unit • - 40VMW024 --- 3 — High Wall Submittal Data Job Data Location Buyer Unit Number Buyer PO # Model Number Carrier # Performance Data Certified By Date STANDARD FEATURES • Dual Guided Air Design Provides Smoother and More Comfortable Air Flow • Three Fan Speeds - High, Medium and Low • Front Panel Lifts Up 65 Degrees Providing Ease of I Maintenance • Heating Mode, Swing Angle for Louver is 68 to 110 Degrees in Auto Mode Non -Heating Mode, Swing Angle for Louver is 61 to 93 Degrees in Auto Mode • Manual Setting for Louver, Swing Angle Between 61 and 110 Degrees • Multi -Refrigerant Outlet Piping Methods - Left, Right or Rear • Built in EXV (Electronic Expansion Valve) for Installation Ease Indoor Unit Model 40VMWO24 --- 3 PERFORMANCE Cooling Rated Capacity Btu/h 24,000 Heating Rated Capacity Btu/h 27,000 Airflow (H / M / L) CFM 650 / 530 / 460 Sound Pressure (H / M / L) dBA 43.2 / 42.0 / 36.8 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Indoor Fan Motor Power W 75 Consumption (Input) Minimum Circuit Amps A 0.86 Maximum Overcurrent A 15 Protection Motor Type DC ACCESSORIES (Optional) ❑ Wireless Remote Controller 40VM900001 ❑ Wired Remote Controller - Non-Prog. 40VM900002 ❑ Wired Remote Controller - Prog. 40VM900003 ❑ Touch Screen Wired Controller 40VM900005 ❑ Touch Screen Central Controller 40VM900006 PHYSICAL DATA Pipe Connection Size - in. 3/8 (OD) Liquid Pipe Connection Size - in. 5/8 (OD) Suction Pipe Connection Size - in. 3/4 NPT (OD) Drain Refrigerant R-410A Unit Width in. 47 Unit Height in. 13-1/2 Unit Depth in. 10-1/8 Unit Net Weight lb 38 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VMW024-C-2SD Pg 1 04-18 Replaces: 40VMW024-C-1SD DIMENSIONAL DRAWING INDOOR UNIT HIGH WALL 40VMWO24 --- 3 D C A 40VMW UNIT SIZE DIMENSION A B C D 024 47 13-1/2 10-1/8 42-3/8 NOTE: All dimensions shown in inches. .,A'fERTEA- C US © Carrier Corporation 2018 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VMW024-C-2SD Pg 2 04-18 Replaces: 40VMW024-C-1SD VRF Indoor Unit , 40VMHO96 --- 3—High Static Duct Turn to the experts Submittal Data Job Name Tag INDOOR UNIT MODEL 40VMHO96 --- 3 PERFORMANCE Cooling Rated Capacity Btu/h 97,350 Sensible Cooling Capacity Btu/h 61,690 Heating Rated Capacity Btu/h 108,000 Airflow (H / M / L) CFM 2824 / 2400 / 2076 Sound Pressure (H / M / L) dBA 56.4 / 54.7 / 52.4 ELECTRICAL Power Supply V/Ph/Hz 208-230/1/60 Power Consumption (Input) w 395 + 395 Minimum Circuit Amps (MCA) A 10.2 Maximum Overcurrent Protection A 15.0 Motor Type DC ACCESSORIES ❑ Wireless Remote Controller 40VM900001 ❑ Wired Remote Controller - Non-Prog. 40VM900002 ❑ Wired Remote Controller - Frog. 40VM900003 ❑ Touch Screen Wired Controller 40VM900005 ❑ Touch Screen Central Controller 40VM900006 Location STANDARD FEATURES • Ducted Supply and Return Opening • Three Fan Speeds - High, Medium and Low • Built in EXV (Electronic Expansion Valve) for Install Ease PHYSICAL DATA Pipe Connection Size - Liquid in. 3/8 (OD) Pipe Connection Size - Suction in. 7/8 (OD) Pipe Connection Size - Drain in. 1-5/8 (OD) Minimum External Static Pressure (ESP) (Factory Default) in. wg 0.2 Maximum External Static Pressure (ESP) in. wg 1.0 Refrigerant R-410A Unit Width in. 56-11/16 Unit Height in. 20 Unit Depth in. 36-13/32 Net Weight lb 254.2 © 2021 Carrier Corporation. All rights reserved. Edition Date: 03/21 Form No: 40VMH096-C-3SD A Carrier Company Printed in U.S.A. Replaces: 40VMH096-C-2SD Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. I DIMENSIONAL DRAWING INDOOR UNIT HIGH STATIC DUCT 40VMHO96 --- 3 �#TERT@� c us C/8TE0 © 2021 Carrier Corporation. All rights reserved. Edition Date: 03/21 Form No: 40VM]11096-C-3SD A Carrier Company Printed in U.S.A. Replaces: 40VMH096-C-2SD Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 2 VRF Controls and Accessories 40VM900003 -Wired Remote Controller Carrier (Programmable) Submittal Data Job Data Location Buyer Unit Number Performance Data Certified By 9 ALU MENU , OK FAN TEMP DOWN �� N Buyer PO # Model Number Carrier # Date 40VM900003 - Wired Remote Controller (Programmable) Features • Back lit easy to read • ON/OFF • Unit addressing capability • Mode setting: cool, heat, dry, fan, and auto • Room temperature display • Fan speed setting • Louver swing operation • Weekly scheduling • Temperature display in 1°F • Set temperature range limiting (62°F to 88°F) • Dual set -point control • Error display • Group Control (Max 16 IDU) • Touch Buttons • Clock WIRING DIAGRAM • Use wire size 20AWG to 16AWG stranded, shielded, 2-core. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VM900003-C-1SD Pg 1 01-17 Replaces: New DIMENSIONAL DRAWING 40VM900003 WIRED REMOTE CONTROLLER (PROGRAMMABLE) 4-3/4 13/16 M co co M 1-3/ 16 2-3/8 NOTE: All dimensions shown in inches © Carrier Corporation 2017 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Printed in U.S.A. Form 40VM900003-C-1SD Pg 2 01-17 Replaces: New Indoor Units: Capacity: 3/1to29 144 / 72 to 144 (100.0%) Total Pipe Length: Furthest Actual: Furthest Equiv.: After 1st Branch Actual: After 1st Branch Equiv.: Max Height Between IDU/IDU: Max Height Between IDU/ODU (Above): Max Height Between IDU/ODU (Below): Correction Factors System Capacity: 1.00 0.95 Temperature: 1.00 1.00 Piping Length: 1.00 1.00 Altitude: 1.00 1.00 Defrosting: - 0.95 Additional Derates: 1.00 1.00 100.0 / 1900.0 feet 50.0 / 541.0 feet 50.0 / 623.0 feet 25.0 / 131.0 feet 25.0 / 131.0 feet 13.0 / 65.0 feet 0.0 / 164.0 feet 25.0 / 131.2 feet Additional Refrigerant: 18.52 lb Total Refrigerant Amount: 62.61 lb Min Allowable Room Volume(cuft): 2408.23 Design Temperatures (°F) Cooling: Indoor DB 80.0 Humidity 51.8% Indoor WB 67.0 Outdoor DB 96.0 Heating: Indoor DB 70.0 Outdoor DB 18.0 Humidity 75.0% Outdoor WB 16.5 12t Meat Recovery I 38VMA144RDL5-1 144,000 BTU/h 152,000 BTU/h 100.0% G 1-1/8/7/8 25.Oft(0) 40VMD006M--3 144,000 BTU/h 162,000 BTU/h G O 5/8/3/8 25.Oft(0) G O 5/8/3/8 25.0ft(0) G O 7/8/3/8 25.Oft(0) O.Oft(0) O.Oft(0) ca. • 9 40VMW024 ... 3 23,904 BTU/h (16,905 BTU/h) 21,213 BTU/h 1 / IDU_ / RC 40VMW024---3 23,904 BTU/h (16,905 BTU/h) 21,213 BTU/h 2 / IDU_ / RC 40VMH096 --- 3 95,616 BTU/h (68,486 BTU/h) 84,850 BTU/h 3 / IDU_ / RC ALL WIRE FOR THE SYSTEM MUST BE SHIELDED & STRANDED 12t Heat Recovery AWG2x18 PQ MDC (Main) AWG2x18 PQ 40VM900003 IDU_ Wired controller (Prog) M Group 1 HA/HB 40VM900003 IDU_ Wired controller (Prog) M Group 2 HA/HB 40VM900003 IDU_ Wired controller (Prog) M Group 3 C& HAIHB