Loading...
REVIEWED ENG BLD2023-0292+Geotechnical_Report+3.7.2023_3.34.40_PM+3407213.,.,.,.,.,.REVIEWED ,.,.,.,.•.• BY CITY OF EDMONDS BUILDING DEPARTMENT May 19, 2021 Updated January 4, 2022 ES-7515 RECEIVED 3/13/23 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Select Homes, Inc. 8304 — 212t" Street Southwest Edmonds, Washington 98026 Attention: Ms. Kayla Nichols Subject: Geotechnical Evaluation Proposed Single -Family Residences 8929 — 220t" Street Southwest Edmonds, Washington Earth Solutions NW«c Earth Solutions NW LLC Geotechnical Engineering, Construction Observation/Testing and Environmental Services Reference: Department of Ecology Stormwater Management Manual for Western Washington Amended December 2014 James P. Minard Geologic Map of the Edmonds East and Part of the Edmonds West Quadrangles Washington, 1983 United States Department of Agriculture (USDA) Web Soil Survey (WSS) Edmonds City Code Chapter 23.80 (Geologically Hazard Areas) RAM Engineering, Inc. Preliminary Engineering Plans, revised October 13, 2021 Dear Ms. Nichols: As requested, Earth Solutions NW, LLC (ESNW) has prepared this geotechnical evaluation report for the proposed single-family residences. As part of our scope of services, we completed a subsurface exploration, laboratory and engineering analyses, in -situ infiltration testing, and prepared this written report with our findings and recommendations for the proposed project. Based on our evaluation, the proposed project is feasible from a geotechnical standpoint. This geotechnical evaluation has been updated to respond to City of Edmonds review comments. 15365 N.E. 90th Street, Suite 100 0 Redmond, WA 98052 6 (425) 449-4704 • FAX (425) 449-4711 Select Homes, Inc. May 19, 2021 Updated January 4, 2022 Response to Comments ES-7515 Page 2 The comments pertinent to the geotechnical aspects of the project are provided below, followed by our responses. ESNW prepared the referenced geotechnical evaluation for the subject project. Review Comment SW32-1 — Expand or clarify the findings of this test as noted: a) Text states test was at contact of till layer, but no layer distinction is shown in the boring log at that elevation; explain/update as needed. b) Expand on what was observed/noted to lead to the conclusion water travelled horizontally. c) Expand engineering opinion of reason for this observation; it appears unusual to the reviewer given the relatively uniform boring logs and without explanation from engineer. d) Explain why perforated pipe connections are considered feasible given finding of infiltration testing; if separation to hardpan layer is infeasibility criteria for all infiltration BMPs, it would also appear to apply to perforated pipe connections. ESNW Response — The following is provided as additional clarification as requested: a) The infiltration test was completed at a depth of approximately four feet at TP-2, which is the same depth noted on test pit log TP-2 where the material changes from brown and loose to medium dense, to gray and medium dense to dense. This transition was interpreted as the transition from weathered glacial till to unweathered glacial till. b) This conclusion was based on the observation that the water from the infiltration test was perched on the unweathered till and began to seep back into the test pit from that transition level as the test pit was advanced deeper after completion of the infiltration test. c) The test pit logs do not illustrate uniform soil conditions from top of the test pits to the bottom of the test pits; changes in color, density, and cementation illustrate the change from weathered till to unweathered till. The water from the infiltration test did not significantly infiltrate vertically into the unweathered till and was observed to seep back into the test pit as it was advanced deeper after completion of the test. Glacial till is a widely documented and prevalent geologic deposit in the Puget Sound region, which consists of weathered till within the upper few feet underlain by unweathered till. The weathered till generally exhibits low to moderate hydraulic conductivity and the unweathered till generally exhibits very low to negligible hydraulic conductivity. This is due to the increased density and cemented nature of the unweathered till. d) Based on proposed grades, the bottom of the perforated stub -out connection trenches would be within the underlying unweathered till. In this respect, perforated stub -out connections should be considered infeasible for the proposed project. We have updated the BMP table in this report accordingly. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 Protect Description ES-7515 Page 3 The subject site is located at 8929 — 220th Street Southwest in Edmonds, Washington, as illustrated on the attached Vicinity Map (Plate 1). The site consists of one tax parcel (Snohomish County parcel number 0038030010-1000) totaling approximately 0.61 acres of land. The property is currently developed with a single-family residence, outbuildings, and associated improvements. Site topography is relatively level with less than about five feet of elevation change. The subject site is bordered to the north, east, and west by single-family residences and to the south by 220th Street Southwest. Based on ESNW's understanding of the proposed development, the subject site will be redeveloped with three single-family residences and associated improvements. We anticipate grading activities will include cuts and fills of about two to four feet to establish the planned building alignments. However, grading plans were not available at the time this report was prepared. We understand infiltration and low impact development methods are being evaluated for stormwater management. Site improvements will also include underground utility installations. At the time this report was prepared, specific building load values were not available. However, we anticipate the proposed residential structures will consist of relatively lightly loaded wood framing supported on conventional foundations. Based on our experience with similar developments, we estimate wall loads on the order of one to two kips per linear foot and slab -on - grade loading of 150 pounds per square foot (psf). If the above design assumptions are incorrect or change, ESNW should be contacted to review the recommendations in this report. ESNW should review the final design to verify the geotechnical recommendations provided in this report have been incorporated into the plans. Subsurface Conditions As part of this geotechnical evaluation, an ESNW representative observed, logged, and sampled five test pits on October 16, 2020, excavated at accessible locations within the proposed development area, using a mini-trackhoe and operator provided by the client. The approximate locations of the test pits are depicted on the Test Pit Location Plan (Plate 2). Please refer to the test pit logs provided as an attachment to this report for a more detailed description of subsurface conditions. Representative soil samples collected at the test pit locations were analyzed in general accordance with the Unified Soil Classification System (USCS) and USDA methods and procedures. Topsoil and Fill Native topsoil was observed extending to depths of approximately two to nine inches below the existing ground surface (bgs). The topsoil was characterized by dark brown color and fine organic material. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 ES-7515 Page 4 Fill was observed at test pit location TP-2. The fill was observed to extend to a maximum depth of roughly 12 inches bgs. The fill was characterized primarily as topsoil and loose silty sand (USCS: SM), and was encountered in a moist condition at the time of exploration. Additionally, fill may be present within proximity to existing structural improvements. Where fill is encountered during construction, ESNW should be consulted to evaluate the suitability for support of the proposed structures and/or reuse as structural fill. Native Soil Underlying the topsoil and limited fill, native soil at the test pit locations was observed to consist primarily of silty sand with and without gravel (USCS: SM). Silt gravel (USCS: GM) was observed within the upper three feet at test pit location TP-5. Overall soil relative density generally increased with depth, extending to the maximum exploration depth of about seven and one-half feet bgs. The native soil was generally observed in a weakly cemented condition beginning at about three and one-half to four feet bgs. Geologic Setting The referenced geologic map resource identifies Vashon till (Qvt) across the site and surrounding areas. As reported on the geologic map resource, Vashon till typically consists of a nonsorted mixture of clay, silt, sand, pebbles, cobbles, and boulders. The till was deposited directly by ice advanced over previously deposited sediment and rocks. In addition, the referenced WSS resource identifies Alderwood-urban land complex (Map Unit Symbol: 5) as the primary soil units underlying the subject site. The Alderwood series was formed in glacial till plains. Based on our field observations, native soils on the subject site are generally consistent with the geologic setting outlined in this section. Groundwater Groundwater seepage was not observed at the test pit locations during the fieldwork (October 2020). However, seepage should be expected in deeper excavations at this site, particularly during the winter, spring, and early summer months. Groundwater seepage rates and elevations fluctuate depending on many factors, including precipitation duration and intensity, the time of year, and soil conditions. Geologically Hazardous Areas Assessment As part of this geotechnical evaluation, the referenced chapter of the ECC was reviewed. Based on our investigation and review, there are no geologically hazardous areas present on or adjacent to the site. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 Foundations ES-7515 Page 5 The proposed structures can be supported on conventional spread and continuous footings bearing on undisturbed, competent native soil, compacted native soil, or new structural fill. Competent native soils, suitable for support of the foundation, should be encountered beginning at depths of approximately two to three feet bgs. Where loose or unsuitable soil conditions are encountered at foundation subgrade elevations during site preparation activities, compaction of the soils to the specifications of structural fill, or overexcavation and replacement with granular structural fill will be necessary. Structural fill should consist of suitable granular soils compacted to 95 percent of Modified Proctor (ASTM D1557). Compaction of the soil to the levels necessary for use as structural fill will be difficult during wet weather conditions. Organic material exposed at foundation subgrade elevations must be removed and grades restored with structural fill. Provided the structures will be supported as described above, the following parameters can be used for design of the new foundations: • Allowable soil bearing capacity 2,500 psf • Passive earth pressure 300 pcf (equivalent fluid) • Coefficient of friction 0.40 The passive earth pressure and coefficient of friction values include a safety factor of 1.5. A one- third increase in the allowable soil bearing capacity can be assumed for short-term wind and seismic loading conditions. With structural loading as expected, total settlement in the range of one inch is anticipated, with differential settlement of about one-half inch. The majority of the settlements should occur during construction, as dead loads are applied. Seismic Considerations The 2015 and 2018 International Building Code recognizes the American Society of Civil Engineers (ASCE) for seismic site class definitions. In accordance with Table 20.3-1 of ASCE, Minimum Design Loads for Buildings and Other Structures, Site Class D, should be used for design. In our opinion, the site susceptibility to liquefaction is negligible. The native soil relative density and the absence of an established, shallow groundwater table are the primary bases for this opinion. Drainage Temporary measures to control surface water runoff during construction would likely involve passive elements such as interceptor trenches and sumps. ESNW should be consulted during preliminary grading activities to evaluate seepage areas and provide recommendations to reduce the potential for seepage -related instability. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 ES-7515 Page 6 Finish grades should be designed to direct surface water away from structures and slopes. Grades adjacent to buildings should be sloped away at a gradient of either at least 2 percent for a horizontal distance of up to 10 feet or the maximum allowed by adjacent structures. In our opinion, foundation drains should be installed along building perimeter footings. Infiltration and LID Evaluation As indicated in the Subsurface Conditions section, native soils encountered during our fieldwork were characterized primarily as silty sand with and without gravel. Based on the results of USDA textural analyses, the native soils at depth were classified primarily as gravelly loamy sand with fines contents of about 18 percent. In -situ testing was completed in accordance with the small-scale pilot infiltration test (PIT) procedure, as outlined in Volume III, Chapter 3, Page 526 of the 2014 SMMWW. The PIT was completed at a depth of approximately four feet at TP-2. The testing was completed at the contact with the unweathered glacial till. The in -situ rate obtained during testing was 23.0 inches per hour (iph); however, based on conditions observed when advancing the test pit after completion of the PIT, it was evident that much of the water infiltrated laterally within the upper weathered soil. We understand the proposed development area of the site is clustered due to tree retention and ECDC 20.75.048. Due to the clustered houses and site improvements, we understand there is limited remaining area for infiltration, bioretention, or dispersion systems and required minimum setbacks. Based on the confining layer observed during the infiltration test, attempting to infiltrate stormwater will create lateral flow along the confining layer and is ultimately not recommended for limited setback conditions. On -site Stormwater Management Pursuant to City of Edmonds stormwater management requirements, implementation of on -site stormwater BMPs are required for proposed developments in accordance with specified thresholds, standards, and lists. The intent of BMP implementation is to infiltrate, disperse, and retain stormwater runoff on site to the extent feasible. The table below summarizes our evaluation of low impact development methods, as outlined in the referenced stormwater manual, from a geotechnical standpoint. It is instructed in the referenced stormwater manual that BMPs are to be considered in the order listed (from top to bottom) for each surface type, and the first BMP that is determined to be viable should be used. For completeness, however, we have evaluated each listed BMP for the proposed surface types. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 ES-7515 Page 7 BMP I Viable? Limitations or Infeasibility Criteria Lawns and Landscaped Areas T5.13: Post -construction soil quality and depth (Volume V, Yes None. Chapter 5 Roofs T5.30: Full dispersion (Volume V, Maybe* T5.30: Adequate vegetative flow paths will likely not be Chapter 5) available. T5.10A: Downspout full infiltration T5.10A: Shallow depth to low permeability soil and limited systems (Volume III, Chapter 3) No setback space due to clustered development. Roofs Bioretention (Volume V, Chapter NO T5.10A: Shallow depth to low permeability soil and limited 7) setback space due to clustered development. T5.1013: Downspout dispersion Maybe* Adequate vegetative flow paths are likely not available. systems (Volume III, Chapter 3) T5.10C: Perforated stub -out Based on proposed grades, the bottom of the perforated connections (Volume III, Chapter No stub -out connection trenches would be within the 3) underlying unweathered till. T5.30: Full dispersion (Volume V, Maybe* Adequate vegetative flow paths are likely not available. Chapter 5) T5.15: Permeable pavement Shallow depth to lower permeability soil would cause (Volume V, Chapter 5) No saturation and instability of soil directly supporting the pavement. Bioretention (Volume V, Chapter NO T5.10A: Shallow depth to low permeability soil and limited 7) setback space due to clustered development. T5.12: Sheet flow dispersion No flooding or erosion impacts are anticipated. However, T5.11: Concentrated flow Maybe* adequate vegetative flow paths are likely not available. dispersion Volume V, Chapter 5 * Viability stated from a geotechnical standpoint and should be determined by site storm designer with respect to setbacks and flow paths. Limitations The recommendations and conclusions provided in this geotechnical evaluation report are professional opinions consistent with the level of care and skill that is typical of other members in the profession currently practicing under similar conditions in this area. A warranty is not expressed or implied. Variations in the soil and groundwater conditions observed at the test pit locations may exist and may not become evident until construction. ESNW should reevaluate the conclusions in this geotechnical evaluation report if variations are encountered. Earth Solutions NW. LLC Select Homes, Inc. May 19, 2021 Updated January 4, 2022 Additional Services ES-7515 Page 8 ESNW should be retained to provide additional geotechnical services in association with this project, including testing and consulting services during construction. ESNW should have an opportunity to review final project plans with respect to geotechnical recommendations provided in this letter. We trust this letter meets your current needs. Should you have questions, or if any additional information is required, please call. Sincerely, EARTH SOLUTIONS NW, LLC Adam Z. Shier, L.G. Project Geologist Attachments: Plate 1 — Vicinity Map Plate 2 — Test Pit Location Plan Test Pit Logs Grain Size Distribution �T'WR �F WA 6. Q "� 53803 Fss/ONAL 01 /04/2022 Henry T. Wright, P.E. Senior Project Manager cc: RAM Engineering, Inc. Attention: Mr. Rob Long, P.E. (Email only) Earth Solutions NW. LLC C ry h r 203rtl Street Southwest D ♦a < Glen Street < ZGlen Street Glen Street 'h, Daley Street zDaley Sheet G Daley Street ° o //SSr Pei Sprague Street °' Sprague Street _ WA 524 c 206th Street Southwest ^ Edmonds Street S� \ Bell Street Pe/r EdrYlond5. ._Main Street_ Main Street ayton Street Dayton Street O �Ma IeW \ <Maple Street (Maple Street N a Yost Park �,, �3<a Alder Street v m i Walnut Street Walnut Street Walnut Street She/ja a 3 \� y a 3 Holly Drive d w Cedar Street y Howell Way m 3 D Spruce Street y Edmonds/ Spruce streeta' Woodway 'D 80"/do/ l High School da n Wdy oa Hem.lock Way p' J Laurel Street 215th Street Southwest s Edmonds wPm Street Chose Lake r" m Pine Street 216th Street Southwest 216th Street Southwest A . c 216th Street Southwest _ l s 9 Elementary 11 D School IFOrsyth Laneg zt 7th Street Southwest 1 ; 3 0 o A 01 Fir Street. 3 v ` A 218th Street Southwest ° SITE o Elm street — =220Ih.Street Southwest_ _—220th-Street.Southwest__ 04 Elm D222nd Street Southwest WA 104 a — Esperance — as Park a P .3 224th Street Southwest 224th Street Southwest_„_ \\d --- — \ v Esperance — n ROa I m \ tSth Srre t o F of Southwest lo 226[h Street Southwest \ D d 228th_St[eeLSou[hwest of 7S a > r Drvi '= Sherwood / Forest d - Edmdn °q\ 230th Street Southwest oad .. 14 3 ^ \ 231st Street Southwest � 9othQa°° 232nd Street Southwest / Holly Lane �F WA99 p 3 o c� c % Edmonds 30 Maple Lane O,q _ ° 00 Heights N 234th Street Southwest gal a� 234th Street South Nottingham Road K72~1 ill Madrona Lane 235Ih Place Southwest a F 236th Street Southwest 236th Street Southwest \ _ Reference: NORTH County, Washington arth 1 1Snohomish i [ENWIULC OpenStreetMap.org .Geotechnical Engineering, Construction Vicinity Map 8929 - 220th Street Southwest Edmonds, Washington NOTE: This plate may contain areas of color. ESNW cannot be responsible for any subsequent misinterpretation of the information Drwn. MRS Date 11 /18/2020 Proj. No. 7515 resulting from black & white reproductions of this plate. Checked AZS Date Nov. 2020 Plate 1 I I ¢zo I - - - - 425_ 1_ _� II r—T-1/� ------I— — — — —— I �—■t I I ,I415 42� I TP-3 1 TP-2 I I I II TP-41 I E] I n t i I I TP-5 1 — I I 11 \ I 415 `420 22OTH STREET S.W. LEGEND NORTH TP-1 Approximate Location of 00� — ■ — ESNW Test Pit, Proj. No. ES-7515, Oct. 2020 Subject Site Existing Building NOT - TO - SCALE NOTE: The graphics shown on this plate are not intended for design ' ' ' purposes or precise scale measurements, but only to illustrate the 0. approximate test locations relative to the approximate locations of existing and / or proposed site features. The information illustrated is largely based on data provided by the client at the time of our Test Pit Location Plan study. ESNW cannot be responsible for subsequent design changes 8929 - 220th Street Southwest or interpretation of the data by others. Edmonds, Washington NOTE: This plate may contain areas of color. ESNW cannot be Drwn. MRS Date 11 /18/2020 Proj. No. 7515 responsible for any subsequent misinterpretation of the information resulting from black & white reproductions of this plate. Checked AZS Date Nov. 2020 Plate 2 Earth Solutions NWLLC SOIL CLASSIFICATION CHART MAJOR DIVISIONS SYMBOLS TYPICAL DESCRIPTIONS GRAPH I LETTER GRAVEL AND CLEAN GRAVELS • �•• .� GW WELL -GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES ° �a o �a o p�o p Q oQ GAP POORLY -GRADED GRAVELS, GRAVEL - SAND MIXTURES, LITTLE OR NO FINES GRAVELLY SOILS (LITTLE OR NO FINES) COARSE GRAINED SOILS MORE THAN 50% OF COARSE GRAVELS WITH FINES ° �0 00 D O GM SILTY GRAVELS, GRAVEL - SAND - SILT MIXTURES FRACTION RETAINED ON NO. 4 SIEVE (APPRECIABLE AMOUNT OF FINES) �±� V CLAYEY GRAVELS, GRAVEL - SAND - CLAY MIXTURES SAND AND CLEAN SANDS SW WELL -GRADED SANDS, GRAVELLY SANDS, LITTLE OR NO FINES MORE THAN 50% OF MATERIAL IS SP POORLY -GRADED SANDS, GRAVELLY SAND, LITTLE OR NO FINES LARGER THAN N0. 200 SIEVE SIZE SANDY SOILS (LITTLE OR NO FINES) SANDS WITH FINES c SM SILTY SANDS, SAND - SILT MIXTURES MORE THAN 50% OF COARSE FRACTION PASSING ON NO. 4 SIEVE (APPRECIABLE AMOUNT OF FINES) CC S CLAYEY SANDS, SAND - CLAY MIXTURES INORGANIC SILTS AND VERY FINE ML SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY CL INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS FINE GRAINED SOILS SILTS AND LIQUID LIMIT LESS THAN 50 CLAYS — — — OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY MORE THAN 50% OF MATERIAL IS SMALLER THAN NO. 200 SIEVE MH INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SAND OR SILTY SOILS SIZE SILTS LIQUID LIMIT AND GREATER THAN 50 CLAYS CH INORGANIC CLAYS OF HIGH PLASTICITY OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS HIGHLY ORGANIC SOILS PT PEAT, HUMUS, SWAMP SOILS WITH HIGH ORGANIC CONTENTS DUAL SYMBOLS are used to indicate borderline soil classifications. The discussion in the text of this report is necessary for a proper understanding of the nature of the material presented in the attached logs. Earth Solutions NW, LLC TEST PIT NUMBER TP-1 YPRII 15365 N.E. 90th Street, Suite 100 PAGE 1 OF 1 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest DATE STARTED 10/16/20 COMPLETED 10/16/20 GROUND ELEVATION EXCAVATION CONTRACTOR Client Provided LATITUDE LONGITUDE EXCAVATION METHOD GROUND WATER LEVEL: LOGGED BY AZS CHECKED BY HTW SL AT TIME OF EXCAVATION NOTES Depth of Topsoil & Sod 6": ivy/forest duff w _ CL ~W _ wJ CO TESTS Q O MATERIAL DESCRIPTION p d7 W Q Z (� 0 TPSL '. : 0.5 Dark brown TOPSOIL, roots Tan silty SAND, loose to medium dense, moist MC = 6.3% SM . 3.0 Gray silty SAND, medium dense, moist MC = 5.9% weakly cemented 5 MC = 2.2% SM MC = 4.0% 7.5 Test pit terminated at 7.5 feet below existing grade. No groundwater encountered during excavation. No caving observed. r Earth Solutions NW, LLC 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 TEST PIT NUMBER TP-2 PAGE 1 OF 1 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest DATE STARTED 10/16/20 COMPLETED 10/16/20 GROUND ELEVATION EXCAVATION CONTRACTOR Client Provided LATITUDE LONGITUDE EXCAVATION METHOD GROUND WATER LEVEL: LOGGED BY AZS CHECKED BY HTW S7 AT TIME OF EXCAVATION NOTES Depth of Topsoil & Sod 2": grass w CL _ w ~W J g TESTS _ Q O u/i Q z 0 SM MC = 10.5% SM MC = 4.9% Fines = 18.1 % 5 SM MC = 13.6% Finpc = 1R F0/ MATERIAL DESCRIPTION 0.3� Dark brown TOPSOIL (Fill) 1.0 Tan silty SAND, loose, moist (Fill) 1.5 Dark brown TOPSOIL Brown silty SAND, loose to medium dense, moist Gray silty SAND, medium dense to dense, moist [USDA Classification: slightly gravelly loamy SAND] -infiltration test at 4', groundwater seepage from test -increasing gravel [USDA Classification: gravelly loamy SAND] Test pit terminated at 7.5 feet below existing grade. No groundwater encountered during excavation. No caving observed. Earth Solutions NW, LLC TEST PIT NUMBER TP-3 YPRII 15365 N.E. 90th Street, Suite 100 PAGE 1 OF 1 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest DATE STARTED 10/16/20 COMPLETED 10/16/20 GROUND ELEVATION EXCAVATION CONTRACTOR Client Provided LATITUDE LONGITUDE EXCAVATION METHOD GROUND WATER LEVEL: LOGGED BY AZS CHECKED BY HTW SL AT TIME OF EXCAVATION NOTES Depth of Topsoil & Sod 2": ivy w _ CL ~W _ wJ g TESTS Q O MATERIAL DESCRIPTION p CL Q Z (� 0 TPSL —n Dark brown TOPSOIL, roots Brown silty SAND, loose to medium dense, moist MC = 6.4% SM 2.5 Gray silty SAND, medium dense to dense, moist MC = 3.0% SM -weakly cemented 5 MC = 5.1 % 6.0 Test pit terminated at 6.0 feet below existing grade due to refusal on till. No groundwater encountered during excavation. No caving observed. Earth Solutions NW, LLC TEST PIT NUMBER TP-4 YPRII 15365 N.E. 90th Street, Suite 100 PAGE 1 OF 1 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest DATE STARTED 10/16/20 COMPLETED 10/16/20 GROUND ELEVATION EXCAVATION CONTRACTOR Client Provided LATITUDE LONGITUDE EXCAVATION METHOD GROUND WATER LEVEL: LOGGED BY AZS CHECKED BY HTW SL AT TIME OF EXCAVATION NOTES Depth of Topsoil & Sod 6": grass/exposed soil w _ CL ~W _ wJ g TESTS Q O MATERIAL DESCRIPTION p CL Q Z (� 0 TPSL '. : 0.5 Dark brown TOPSOIL Brown silty SAND, loose to medium dense, moist MC = 9.0% SM 2.0 Gray silty SAND, medium dense to dense, moist MC = 2.1 % -weakly cemented SM 5 MC = 8.1 % 7.0 Test pit terminated at 7.0 feet below existing grade. No groundwater encountered during excavation. No caving observed. Earth Solutions NW, LLC TEST PIT NUMBER TP-5 YPRII 15365 N.E. 90th Street, Suite 100 PAGE 1 OF 1 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest DATE STARTED 10/16/20 COMPLETED 10/16/20 GROUND ELEVATION EXCAVATION CONTRACTOR Client Provided LATITUDE LONGITUDE EXCAVATION METHOD GROUND WATER LEVEL: LOGGED BY AZS CHECKED BY HTW SL AT TIME OF EXCAVATION NOTES Depth of Topsoil & Sod 9": grass w _ CL ~W _ wJ g TESTS Q O MATERIAL DESCRIPTION p CL Q Z (� 0 TPSL Dark brown TOPSOIL, roots a.� 0.7 ° ° Brown silty GRAVEL with sand, loose to medium dense, moist MC=7.1% ° Fines = 20.0% GM 0 ° ° [USDA Classification: very gravelly sandy LOAM] 3.0 Gray silty SAND, medium dense to dense, moist MC = 2.4% -weakly cemented 5 SM MC = 10.6% 7.0 Test pit terminated at 7.0 feet below existing grade. No groundwater encountered during excavation. No caving observed. Earth Solutions NW, LLC GRAIN SIZE DISTRIBUTION 15365 N.E. 90th Street, Suite 100 Redmond, Washington 98052 Telephone: 425-449-4704 Fax: 425-449-4711 PROJECT NUMBER ES-7515 PROJECT NAME 8929 - 220th Street Southwest U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS I HYDROMETER 6 4 3 2 1 5 1 1/2W 3 4 6 810 1416 20 30 40 50 60 100140 200 100 95 90 85 80 75 70 65 w 60 55 m w 50 z LL 45 z w � 40 w a 35 30 25 20 15 10 5 0 100 10 1 0.1 0.01 0.001 GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL SAND W N U) z