BLD2024-0737_Manufacturer_Specifications_and_Installation_Instructions_6.3.2024_8.44.45_AM_4295469Regency° Gi25LE Gas Insert MODEL Gi25LE-NG Fuel Type Natural Gas Minimum Supply Pressure 5" W.C. (1.25 kPa) Manifold Pressure - High 3.5" W.C. (0.87 kPa) Manifold Pressure - Low 1.6" W.C. (0.39 kPa) Orifice Size - Altitude 0-4500 ft (0-1370m) #38 DMS (0-2000 ft.) #39 DMS (2000 - 4500 ft.) Orifice #44 DMS This appliance shall not be field converted. Approved for NG gas only. Fireplace Dimensions The minimum fireplace clearances and dimensions for the Regency gas insert are shown in the following diagrams: Letter Description Dimensions (inches) Dimensions (mm) A Width 26" 660 mm B Outerbox Width 24-3/4" 629 mm C Outerbox Height 17" 432 mm D Outerbox Depth 16-1/4" 413 mm E Outerbox Rear Width 15" 381 mm F Front to Top Taper 8-1/4" 210 mm G Front to Side Taper 2-11/16" 68 mm H Rear to Side Taper 13-5/8" 346 mm I Gas Inlet Height 1-1/4" 32 mm J Gas Inlet Rear Depth 4-7/8" 124 mm K Gas Inlet Front Depth 11-1/2" 292 mm L Electrical Access Height 1-1/8" 29 mm M Electrical Access Rear Depth 3" 76 mm N Electrical Access Front Depth 13-1/4" 337 mm O Glass Viewing Area Width 19-1/2" 495 mm P Glass Viewing Area Height 11-5/8" 295 mm Q Front to Intake 11-15/16" 303 mm R Front to Exhaust 11-15/16" 303 mm S Intake Diameter 3" 76 mm T Exhaust Diameter 3" 76 mm Gi25LE Gas Insert Faceplate Dimensions Three -Sided Faceplate Four -Sided Faceplate CT Faceplate Dimensions Width (A) Height (B) Depth (C) Bottom Height (D) 3-Sided Regular Faceplate 35-3/4" (908 mm) 23-1/4" (591 mm) 1-1/4" (32 mm) 3-Sided Flush Faceplate 35-3/4" (908 mm) 23-1/4" (591 mm) 1/8" (3 mm) - 4-Sided Flush Faceplate 35-3/4" (908 mm) 26-3/8" (670 mm) 1/8" (3 mm) 4-1/4" (108 mm) 3-Sided Finishing Trim 28-1/4" (718 mm) 18-3/4" (476 mm) 1/16" (2 mm) - 4-Sided Finishing Trim 28-1/4" (718 mm) 20" (508 mm) 1/16" (2 mm) 1-1/8" (29 mm) 3-Sided Oversized Backing Plate 44-5/8" (1134 mm) 29-5/8" (737 mm) 1/8" (3 mm) - 3-Sided Custom Backing Plate 30-1/4" - 56-7/8" (768 mm - 1445 mm) 19-3/4" - 44-7/8" (502 mm - 1118 mm) 1/8" (3 mm) - 4-Sided Custom Backing Plate 30-1/4" - 69" (768 mm - 1753 mm) 22-1/8" - 45" (562 mm - 1143 mm) 1/8" (3 mm) 2-1/8" minimum (54 mm min.) Gi25LE Gas Insert Minimum Clearances to Combustibles The clearances listed below are minimum distances unless otherwise stated. A major cause of fires is failure to maintain required clearances (airspace) to combustible materials. It is of the greatest importance that this decorative gas appliance is installed only in accordance with these instructions. Diagram 1 Clearance Dimension Measured From: A: Sidewall 8" / 203 mm ***From inside edge of faceplate / doors B: Ceiling 60" / 1524 mm From base of unit C: Min. Alcove Width 54" / 1372 mm From side wall to side wall D: Max. Alcove Depth 36" / 914 mm From the front of the unit. A hearth is recommend but not required in front of this appliance. If bringing combustible flooring up to the appliance it must be at the same level or lower than the appliance base. No combustible • material is permitted underneath the appliance. • **For mantle clearances, see next page. • (E):***Measured from the insideedgeofthefaceplate/doors-referenceonly:19-9/16"(497mm) Gi25LE Gas Insert Mantel Clearances Without Mantel Deflector �lr REGENC FIREPLACE PRODU Mgfi Mantel Clearances With 2-1/4" (57 mm) Mantel Deflector CO CO V CV CD 00 (O <V O 30" 30" 28' 28" 26" A 26" 24" 24" A 22" 22" 20" 20" 18" a 18" I—D 16" 16" 14" B 14" 12" 12" B 10" C 10" E C 8" G 8" G 6"_F 6 Mantel F Deflector 4 4„ 2" 2" 0" 0„ Top of fireplace Top of opening fireplace opening H H 6 ® 6 Diagram 2 A 12" (305 mm) B 25-1/2" (648 mm) C 21" (534 mm) D 6" (152 mm) E 1" (25 mm) F 16-1/2" (419 mm) G Non Combustible Materials H 16-5/8" (422 mm) to base of unit Although this appliance passes safety certification, the hearth in front of the fireplace becomes very hot when the fireplace heats. Do not use the hearth as a seat or shelf. Diagram 3 A 12" (305 mm) B 20-1/2" (521 mm) C 16" (407 mm) D 6" (152 mm) E 1" (25 mm) F 11-1/2" (292 mm) G Non Combustible H 16-5/8" (422 mm) to base of unit • A 2-1/4" (57 mm) mantel deflector reduces mantel height to 28-1/8" (714 mm) from the base of the unit at 1" (25 mm) depth. • A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. The non-combustible mantel, when installed at a lower overall height, may not be lowerthan 6" (152 mm) from the top of the fireplace opening. • All material used must be non-combustible. 4 1 Gi25LE Gas Insert r1r REGENCY FIREPLACE PRODUCTS Minimum Fireplace Opening Sizes with Varying Faceplate/Backing Plate Options Faceplate Dimensions Minimum Install Width (A) Minimum Install Height (B) Minimum Install Depth (C) Minimum Rear Width (D) Taper Depth (E) 3-Sided Regular Faceplate 25" (635 mm) 17" (432 mm) 15" (381 mm) 15" (381 mm) 1-5/8" (42 mm) 3-Sided Regular Faceplate w/ 3-Sided Backing Plate 26-3/4" (680 mm) 18-1/4" (464 mm) 15" (381 mm) 15" (381 mm) 3-1/8" (80 mm) 3-Sided Flush Faceplate 26-1/2" (673 mm) 18" (457 mm) 16-1/4" (413 mm) 15" (381 mm) 2-5/8" (67 mm) 3-Sided Flush Faceplate w/ 3-Sided Backing Plate 26-3/4" (680mm) 18-1/8" (461mm) 16-1/8" (410mm) 15" (381mm) 4" (102mm) 4-Sided Flush Faceplate 26-1/2" (673mm) 18-1/8" (461mm) 16-1/4" (413mm) 15" (381mm) 2-5/8" (67mm) 3-Sided Finishing Trim 26-1/2" (673mm) 18" (457mm) 16-1/4" (413mm) 15" (381mm) 2-5/8" (67mm) 3-Sided Finishing Trim w/ 3-Sided Backing Plate 26-3/4" (680mm) 18-1/4" (464mm) 16-1/8" (410mm) 15" (381mm) 4-1/4" (108mm) 4-Sided Finishing Trim 26-1/2" (673mm) 18-1/8" (461mm) 16-1/4" (413mm) 15" (381mm) 2-5/8" (67mm) Gi25LE Gas Insert OREGENCY FIREPLACE PRODUC Using Steel Studs and Concrete Board Over Masonry Brick Fireplace The masonry front brick facing can be removed and replaced with non-combustible materials such as steel studs and concrete board/dura rock/micor board as per diagram 1, only if safe to do so. Steel stud may also be placed in front of the masonry brick if left in place. This is the preferred method depending on the condition of the masonry brick fireplace. The opening between the front of the masonry firebox and non-combustible materials such as steel studs must be sealed so heat cannot run between the face of the masonry fireplace and the refacing materials. Only finishing materials such as tile, stone, brick, or similar materials that are non-combustible may be used. Use materials that are uniform so that when the unit is positioned, there are no visible gaps on the sides or top of the surround. Non-coml material c This space DIMENSIONS A - Horizontal clearance 6" (152 mm) B - Vertical clearance 20" (508 mm) C - Opening Width 26" (660 mm) D - Opening Height 17-3/4" (451 mm) E - Minimum Total Width 38" (965 mm) F - Minimum Total Height 37-3/4" (959 mm) Combustible Facing Over ❑ Combustible Framing Non -Combustible Facing Over Non -Combustible Framing 09 6 1 Gi25LE Gas Insert Only people licensed to work with gas piping may make the gas connections to this appliance. 1. If the appliance is installed into an existing chimney system, thoroughly clean the masonry or factory -built fireplace. 2. The appliance hasan opening on the leftside of the control compartment. A 3/8" NPT gas supply pipe must be brought near the opening. 3. Locate the centre point where the vent will pass through the chimney, above the appliance. Move the appliance to the installation location. Ensure that the insert is level. 4. Do not cut any sheet metal parts of the fireplace into which the gas insert will be installed. 5. If the factory -built fireplace has no gas access hole(s), drill one of 1-1/2" (37-1/2 mm) or less through the lower sides or bottom of the firebox. The access hole must be plugged with non-combustible insulation after the gas supply line is installed. Vertical Venting This appliance was tested and certified as a complete system with the noted termination caps and flex liner. Onlythe listed termination caps/flex liner noted below can be used. Use of termination caps or flex liners not listed in this manual will void the warranty and certification of this appliance. It is also important notto enclose the termination cap inside a masonry chimney rain cap, or similar. When attaching the two 3 inch (76 mm) liners to the termination cap and prior to sliding them down the chimney, it is good practice to mark the liners "exhaust" & "air intake". This prevents mixing up • the liners at the flue collar connection of the appliance. If facing the appliance from the front, the air intake is located on the left and the exhaust flue on the right. 3as 0�� filet . -� - lei Gas & Electrical Connections THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. INSTALLATION WITH 3" X 3" LINERS This appliance is designed to attach to two 3" (76 mm) co -linear aluminum flex running the full length of the chimney. The flue length must be a minimum of 10' (3.05 m) and a maximum of 35' (10.7 m) long. See the chart below for minimum distances from the roof. Periodically check that the vent is unrestricted. Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible (avoid unnecessary bending). Attach both the exhaust and intake flue liners to both the termination cap & flue collar at the appliance with a minimum of three self -tapping screws. Use Mil-Pac sealant to seal the pipes. The air intake pipe must be attached to the inlet air collar of the termination ca p. Gi25LE Gas Insert Venting Part # Description 948-305 3" Flex - 35 ft. (intake & exhaust) 946-529 Regency Co -linear DV Vertical Termination Cap & Flashing Vent Run Vent Restrictor Position Burner Aeration Setting 10'to 15' 3" Open 1/4" 15' to 25' 3-1/2" Open 1/4" 25'to 35' 2-1/2" Open 1/4" NOTE: See instructions in the "Vent Restrictor Position" section on positioning of the vent restrictor. FPI Co -linear DV Vertical Termination Flashing E E Full continuous length o (unit to cap) isiE: required for both Ln intake & exhaust.o E E E E X m Air Exhaust Intake Flue Alternative Approved Venting Components* 46DVA-VCH High Wind Cap 46DVA-GK 3" Co -linear Adaptor with flashing Note: Both Air Inlet/Exhaust Liners would need to be purchased separately as they are not included. Simpson Dura-Vent pipe lengths can be added if required to meet clearance requirements. or 46DVA-CL33 Co -Linear Kit w/Flex Note : The 46DVA-CL33 includes high wind cap,flashing & 35 foot liners for both exhaust/intake. In areas of consistently high winds, we recommend using the Simpson Dura-Vent System 46DVA-GK adapter and 46DVA-VCH high -wind cap or 46DVA-CL33 Co -Linear Kit w/Flex. The Air Intake pipe must be attached to the inlet air collar of the termination ca p. *NOTE: Simpson Duravent can only be used with 3" liners. OREGENCY FIREPLACE PRODUC The Gi25LE is also approved for use with a 2" liner for air intake and a 3" liner for exhaust. This would be suitable for a Class A wood burning chimney with a minimum 6" round flue. The chimney must be lined with one 2" diameter liner for intake and one 3" diameter liner for exhaust. The minimum vent length is 10' (3.05 m) and maximum is 35' (10.7 m). INSTALLATION WITH 3" & 2" LINERS Part # Description 948-305 3" Flex - 35 ft. (exhaust) 948-316 2" Flex - 35 ft. (intake) 946-582 Regency Co -linear DV Flashing & 2" Collar Vertical Termination Cap, Vent Restrictor Burner Aeration Vent Run Position Setting 10'to 15' 4" Open 1/4" 15' to 35' 6" Open 1/4" NOTE: See instructions in the "Vent Restrictor Position" section on positioning of the vent restrictor. FPI Co -linear DV Vertical Termination Cap Flashir Full continuous length (unit to cap) is required for both intake & exhaust. Air Intake 2" Liner �n ^ o CO Mo o� � M E E E E X 3" Liner Exhaust flue 8 1 Gi25LE Gas Insert Vertical Venting/Restrictor Settings for FPI Co -Linear DV Vertical Termination Cap & Flashing (946-529) Flex Pipe 3" x 3" 37 35 - - - - -- 33 31 29 27 25 -- - - - - -- LL 1-0 23 4-, L 0) N 21 U 19 a- J L > 17 15 - - - - - -- 13 11 9 7 5 3 0 '-1/2" open -1/2" open ;" open Flex Pipe 3" x 2" 37 35 - - - - -- 33 31 29 27 N 25 N LL 1-10 23 4-, 0) N 21 U 19 L � 17 i" open E" open Gi25LE Gas Insert 1 9 Vertical Venting/Restrictor Settings for FPI Co -Linear DV Vertical Termination Cap & Flashing (946-529) Enclosed IMPORTANT: Vent cap clearances to Sides and Top must be followed. See next page for important clearance requirements when termination cap is enclosed above and on 2 sides. 37 35 33 31 29 27 25 LL 4-, 23 0) N 21 2 U 19 a=+ i 17 Flex Pipe 3" x 3" Original Masonry Chimney Rain Cap Tiii;_ - K-- - - 15 13 11 9 7 5 3 1 0-- - - - - -- i" open 10 1 Gi25LE Gas Insert Vertical Venting/Clearance Requirements for FPI Co -Linear DV Vertical Termination Cap & Flashing (946-529) Enclosed When installed with 46DVA-CL33 or 46DVA-GK + 46DVA-VCH + 3" FPI Flex (Exhaust/Air Intake) These vent kits cannot be enclosed and must be exposed on all 4 sides and above. Situation 1 SIDE VIEW 1V 25 mm) -------------------------------------------------------- TOP VIEW 6" 24" (25 mm) -' (25 m Air Intake Eust 10 mm) I 6" 0 52 mm) Situation 2 SIDE VIEW 1" -------------------------------------------------------- TOP VIEW 6" 0 52 mm) 0" 2 T 2 mm) Exhaust (6 0 mm) Air Intake 6" 052 mm) Note: Restrictor must be set to 5" (127 mm) open, see Restrictor Adjustment. SIDE VIEW TOP VIEW Situation 3 1" 25 mm) 4" 002 mm) 2-1/2" (4 m 24" (610 mm) 4" 0 02 1 Situation 4 SIDE VIEW 1" (25 mm) min. ti Ll Li -------------------------------------------------------- TOP VIEW 4" 0 02 mm) 2-1/2" 2-1/2" 24" 4m ) 4m )( 10mm) 4" (102 mm) Gi25LE Gas Insert 1 11 Vertical Venting/Restrictor Settings for Simpson Dura-Vent Termination Caps When installed with: 46DVA-CL33 or 46DVA-GK + 46DVA-VCH + 3" FPI Flex (Exhaust/Air Intake) 37 35 - - - - -- 33 31 29 27 ,--Is 25 - - - - -- Q) ILL. 23 4-, 0) N 21 2 V 19 > 17 15 - - - - -- 13 11 9 7 5 3 0 2-1 /2" open 3-1 /2" open 12 1 Gi25LE Gas Insert