North
Stub out 6'& Cap.
ELECTRICAL
BLOCKOUT 6" DIA
F
_17
9
2
4
4"
SEE FLOOR
DRAIN DETAIL SEE 2'-0"x1'-4"
BLOCKOUT DETAIL
2"
8
1 1/4"�
7
3
5
1
S-6 1/16"
8'-0 1/16"
9'-4 1/16"
12'-0"
BELOW FLOOR PIPING — KEY NOTES
1. 4" CLEAN OUT TO GRADE.
2. 2" FLOOR DRAIN. FIELD INSTALLED W/ TRAP SEAL SYSTEM IF OPTION IS ACCEPTED, INSTALL AS
SHOWN W/ VENT & WASTE PIPE. (24%16" BLOCKOUT)
3. 2" VENT EXTENDED 12" ABOVE FINISHED FLOOR LEVEL,
(1 FOR EA FLOOR DRAIN IF FLOOR DRAIN OPTION ACCEPTED) PROVIDE TEST PLUG. (24%16"
BLOCKOUT)
4. 4" WASTE PIPE EXTENDED 12" ABOVE FINISHED FLOOR LEVEL, PROVIDE TEST PLUG. (24%16"
BLOCKOUT)
5. 1 1/4" TYPE K or L ANNEALED 'SOFT' COPPER WATER SERVICE EXTENDED 12" ABOVE FINISHED FLOOR
LEVEL, PROVIDE TEST CAP AT END. (24%16" BLOCKOUT)
6. 30" MIN. BURY, PROVIDE TRACER TAPE.
7. MIN. BURY PER LOCAL REQUIREMENTS TO PROTECT AGAINST FREEZING AND DAMAGE.
8. 2" FLOOR DRAIN. FIELD INSTALLED W/ TRAP SEAL SYSTEM IF OPTION IS ACCEPTED, INSTALL AS
SHOWN W/ VENT & WASTE PIPE. (10" DIA BLOCKOUT)
U It.
1 1/4" Copper Wa
Stub out 6' & cap.
Footing Drain. Stl
System not shows
Connect to exist.
drain.
Roof Drain.
Roof Drain.
4" PVC Inside Pipe Fit Cleanout
— with 4-1/2" Nickel Bronze Round
Cover, typ.
Side Sewer Backflow
Preventer. See City Std.
6 Detail SS-211. Max 4'
from building.
2'-0" x V-4" BLOCKOUT DETAIL
PIPING LEGEND
BELOW FLOOR WASTE
PIPING SCH 40 PVC
ASTM D2665 TYPE DWV
BELOW FLOOR VENT
PIPING SCH 40 PVC
ASTM D2665 TYPE DWV
1 1/4" WATER SERVICE
ANNEALED "SOFT"
COPPER ASTM B88,
TYPE 'K' OR 'L' a.
FLOOR DRAIN DETAIL NOTES
A. CAST —IN DRAIN HOUSING (10" INSIDE DIM — PROVIDED BY CXT) ',
B. FIELD INSTALLED GROUT, SLOPE TO DRAIN (CXT PROVIDED —INSTALLATION NOT BY CXT)
C. 2" WASTE PIPE — STUB UP 12" ABOVE GRADE (NOT BY CXT)
D. 2" TRAP SEAL PART# P26001 (CXT PROVIDED —INSTALLATION NOT BY CXT) ,
E. P—TRAP ASSEMBLY (NOT BY CXT)
F. 2" FLOOR DRAIN VENT RISER — STUB UP 12" ABOVE GRADE (NOT BY CXT)
Stub out a 6" pipe from
tee and cap at 6' from
building. a
ALL PIPING INDICATED ON
THIS SHEET IS NOT BY CXT
u�
i
a a
a e a
GRADE— °
U
C
E
FLOOR DRAIN DETAIL
18FBS2300168
24" x 16"
F) FPLUMBING
BLOCKOUT
—TO MAIN f
WASTE LINE
V,[,IAt�I
ego :wns�'�ti C�9
L
EXPIRES Aril 23, 2025
September 29, 2023
Uw Foster
CXT® Products
6701 E Flamingo Ave Bldg 300 Nampa, ID 83687
901 N. Highway 77 Hillsboro, TX 76645
362 Waverly Road 1Mlliamstown, WV 26187
OZARK 1
BUILDING NUMBER OZ1-319
Nonce
The information contained herein is proprietary and the
exclusive property of CXT Incorporated. The information
may only be used by the original recipient far the purpose
intended. Reproduction or distribution of this information
s stricay prohibited without the prior written consent of
CXT Incorporated. By allowing use of this information,
CXT Incorporated grants no warranty, express or implied,
including a warranty of merchantability or of fitness for a
particular purpose.
CXT Ines,parstsd
FLOOR DRAIN LOCATIONS
\ND BELOW FLOOR PIPIN(
Page 7 of 12