Loading...
FIR2022-0142+Fire_Alarm_Equipment_Specification_Sheets+12.29.2022_8.47.03_AM+3289299Block Diagram — AES Radio Interface with Existing Fire Alarm System: EQUIPMENT TO REPLACE POTS SYSTEM (NEW) FIRE SUBSCRIBER 1 2 EXISTING FIRE ALARM SYSTEM (TO REMAIN) FACP TYPICAL NAC OUTPUTS HORNS, STROBES, BELLS... NOTES (CLASS B SYSTEM): O120VAC MAIN POWER FOR THE FIRE ALARM SYSTEM (RE -USE EXISTING). THIS SYSTEM REQUIRES A DEDICATED CIRCUIT THAT IS LABELED. "FIRE ALARM CIRCUIT "AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL I OCIRCUIT BREAKER LOCATION IS) SHALL BE PERMANENTLY PO STEM NOTED AT ALL FIRE ALARM PANELS AES Radio System Battery Requirement: Technical Specifications Pnwpr cainniv TYPICAL ALARM INPUTS DETECTORS, PULL STATIONS... TYPICAL SUPERVISORY INPUTS DUCT SMOKE DET., TAMPER SWITCHES... Source Requirements External Class 2 AC Transformer and Tratlsfornler VoltageTrequerwy: GO V AC 60 Hz Rechargeable Backup Battery Input Current: 1.9 A max. currew (40 VA min.) Input Voltage: 16.5 V AC 12 V DC — Lead Acid Gel Cell — 10 to 12 Ali — configuration dependent. See Table 1— Battery Size Requirements for details. 24 V DC from External Re_ulated Power Supply UL Listed 24 V DC Regulated Power Supply with 12 V DC Rechargeable 12 V DC Rechargeable Backup Battery Backup Battery in Subscriber in Subscriber Input Voltage: 24 V DC Input Current: 1.3 A Maximum UL Listed FACP with Rechargeable Back -tip Battery 24 V DC Regulated Power Supply Input Voltage: 24 V DC from FACP AUX Power Input Current: 1.3 A Maximum Rechargeable Backup Battery in FACP Fire Alarm System Operations Matrix: EXISTING FIRE ALARM SYSTEM OPERATIONS MATRIX BUILDING FACP (NOT SHOWN) AC POWER LOSS BUILDING FACP (NOT SHOWN) BATTERY POWER LOSS FIRE SUBSCRIBER AC FAILURE FIRE SUBSCRIBER CHARGER TROUBLE FIRE SUBSCRIBER LOW BATTERY CONDITION Vl r L 2 EXISTING FIRE ALARM SYSTEM OPEN CIRCU'- EXISTING FIRE ALARM SYSTEM GROUNC :- _ _- EXISTINGFIRE ALARM SYSTEM TF ._-_ EXISTING FIRE ALARM SYSTEM- ALARI. EXISTING FIRE ALARM SYSTEM- SUPERVISOR, I OUTPUTS I z 3 0 Z� 3 oZ U N w Z Z U U U S LL (0 LL LL Z U Z O Z sZ 1 Z Z -1 Z 6 O RECEIVED Dec 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0142 Table 1. Battery Size Requirements Battery System Configuration Size Description Current (mA) (12 V) -07 See Current C'onsnnnption under Technical Specifications 7794A (IntelliPro FireModule) on page S. 7194A Installation and Operation Manual. and 12 Ali 7711 8 zone input card 7711 Installation and Operation Manual 7707 See Current Consumption wider Technical Specifications 7794A (IntelliPro Fire Module) on page 8. 7794A Installation and Operation Manual and 12 Ah 7712 (8 zone input card - 4 ea. 7712 Installation and Operation Manual EOL and 4 ea. reverse polarity) 7707 1 See Current Consnwnption wider TechNcal Spednca s 1. Ah 7794A (IntelliPro Fire Module) on page 8 and 1794A Installation and p g Operation htanunal