Loading...
APPROVED BLD FIR BLD2024-0419 GARAGE PLANS10 City Of Edmonds Building Department -------- ------- Work GARAGE DRYWALL REPAIR Address� -------- 128 - 4TH - AVE - S ------ --------------------------- --------------- ---- Owner'L COPPERSTONE CONDOS ...... ----------------------------- Approved Date: Building Official Permit Number:- - BLD2-024�041-9 ------ -------------------------- FTP—P--ved--� IDIFIM cl,&ft 'n t' Fire "County South Date: .3127 2 21 03-27-2024 PLAN REVIEW NOTES: APPROVED NO COMMENTS FROM FIRE. DFM BURT C C 1,L IAI 6 A e- (5-A 3,3G0 s, r- I-. St--L= Zi sr, rTA CH(7b r RECEIVED Mar 27 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Quality One Painting & Drywall 24208 57111 Ave. W. Mountlake Terrace, WA 98043 206-941-0393 Qualityonepd@hotmail.com Project: GARAGE CEILING 128 4`h Ave. S. Edmonds, WA 98020 • Install R-30 Unfaced Insulation to an area of 40' x 84' a total of 3360 Sq. Ft. • Hang three layers of 5/8" drywall, including RC -Channel every 16" in. after • first layer, a total of 3360 Sq. Ft, each layer of drywall. • Fire tape, mud, alljoints. • Sand, one coat of PVA Primer. • Spray paint ceiling with rollback. • Includes clean up and pressure wash floor area. 2 DESIGN NO TJM/FCA 60-01 ASSEMBLY RATING 60 MINUTE FLOOR/CEILING A55EMBLY 5TC 54 WITH MINIMUM 1-1/2" OF TOPPING i RESILIENT CHANNELS L4 '.p (1) TOPPING (OPTIONAL) - LIGHTWEIGHT CONCRETE OR PROPRIETARY TOPPING. (2) SUBFLOORING - 5/8' T s G PLYWOOD OR ORIENTED STRANDBOARD (055). (5) 5TRUGTURAL MEMBERS - TJI SERIES JOISTS, PRODUCT FIRE CLASS B-H, MAXIMUM SPACING 15 19.2. O.G., MAY BE SPACED AT 24' O.G. IF 3/4' PLYWOOD 5UBFLOORING 15 USED. SEE SECTION 4 FOR GENERAL INFORMATION. (4) GYPSUM BOARD - THREE LAYERS, 5/8" USG/CGC "51-1EETROGK FIRE CODE C", OR WESTROC 'FIREBOARD G' GPPSUM BOARD. THE BASE LAYER INSTALLED WITH LONG DIMEN51ON PERPENDICULAR TO JOISTS END JOINTS CENTERED ON JOISTS. FACED AND MIDDLE LAYERS INSTALLED PERPENDICULAR TO FURRING CHANNEL, END JOINTS CENTERED ON CHANNEL. ALL GYPSUM BOARD SCREWS SPACED 8" O.G., LOCATED 1-1/2' FROM 51DE JOINTS AND 3/4' FROM END JOINTS. ALL MIDDLE AND FACE LAYER JOINTS TO BE STAGGERED. 0) FURRING CHANNELS - RESILIENT CHANNEL OR HAT CHANNELi INSTALLED 16" O.G. AND ATTACHED TO EACH J015T WITH 1-1/8" TYPE W `ZRrr5• NT5 I6 2-HR. FLOOR/GE I L I NG A55EMBLY The repairs shall meet or exceed the original design. If contractor is unable to source proprietary materials as noted, an alternate 2 hour assembly that will work with the original design shall be presented for review. BLD2024-0419 RECEIVED Mar 27 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2 of 2