APPROVED BLD FIR BLD2024-0419 GARAGE PLANS10
City Of Edmonds
Building Department
-------- -------
Work GARAGE DRYWALL REPAIR
Address� -------- 128 - 4TH - AVE - S ------
---------------------------
--------------- ----
Owner'L COPPERSTONE CONDOS ......
-----------------------------
Approved Date:
Building Official
Permit Number:- - BLD2-024�041-9 ------
--------------------------
FTP—P--ved--�
IDIFIM cl,&ft
'n t' Fire
"County
South
Date: .3127 2 21
03-27-2024
PLAN REVIEW
NOTES: APPROVED NO
COMMENTS FROM FIRE.
DFM BURT
C C 1,L IAI 6 A e- (5-A 3,3G0 s, r- I-.
St--L=
Zi sr, rTA CH(7b r
RECEIVED
Mar 27 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Quality One Painting & Drywall
24208 57111 Ave. W.
Mountlake Terrace, WA 98043
206-941-0393
Qualityonepd@hotmail.com
Project: GARAGE CEILING
128 4`h Ave. S.
Edmonds, WA 98020
• Install R-30 Unfaced Insulation to an area of 40' x 84' a total of 3360 Sq. Ft.
• Hang three layers of 5/8" drywall, including RC -Channel every 16" in. after
• first layer, a total of 3360 Sq. Ft, each layer of drywall.
• Fire tape, mud, alljoints.
• Sand, one coat of PVA Primer.
• Spray paint ceiling with rollback.
• Includes clean up and pressure wash floor area.
2
DESIGN NO TJM/FCA 60-01
ASSEMBLY RATING 60 MINUTE
FLOOR/CEILING A55EMBLY
5TC 54 WITH MINIMUM 1-1/2" OF
TOPPING i RESILIENT CHANNELS
L4 '.p
(1) TOPPING (OPTIONAL) - LIGHTWEIGHT CONCRETE OR PROPRIETARY
TOPPING.
(2) SUBFLOORING - 5/8' T s G PLYWOOD OR ORIENTED STRANDBOARD
(055).
(5) 5TRUGTURAL MEMBERS - TJI SERIES JOISTS, PRODUCT FIRE CLASS
B-H, MAXIMUM SPACING 15 19.2. O.G., MAY BE SPACED AT 24' O.G. IF
3/4' PLYWOOD 5UBFLOORING 15 USED. SEE SECTION 4 FOR GENERAL
INFORMATION.
(4) GYPSUM BOARD - THREE LAYERS, 5/8" USG/CGC "51-1EETROGK FIRE
CODE C", OR WESTROC 'FIREBOARD G' GPPSUM BOARD. THE BASE
LAYER INSTALLED WITH LONG DIMEN51ON PERPENDICULAR TO JOISTS
END JOINTS CENTERED ON JOISTS. FACED AND MIDDLE LAYERS
INSTALLED PERPENDICULAR TO FURRING CHANNEL, END JOINTS
CENTERED ON CHANNEL. ALL GYPSUM BOARD SCREWS SPACED 8"
O.G., LOCATED 1-1/2' FROM 51DE JOINTS AND 3/4' FROM END JOINTS.
ALL MIDDLE AND FACE LAYER JOINTS TO BE STAGGERED.
0) FURRING CHANNELS - RESILIENT CHANNEL OR HAT CHANNELi
INSTALLED 16" O.G. AND ATTACHED TO EACH J015T WITH 1-1/8" TYPE W
`ZRrr5• NT5
I6 2-HR. FLOOR/GE I L I NG A55EMBLY
The repairs shall meet or exceed the original
design. If contractor is unable to source
proprietary materials as noted, an alternate 2
hour assembly that will work with the original
design shall be presented for review.
BLD2024-0419
RECEIVED
Mar 27 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
2 of 2