REVIEWED LOCKED BLD2024-0542+Manufacturer_Specifications_and_Installation_Instructions+3.29.2024_8.29.30_AM+4164687Protector® QS Series INCLUDES: • Two -Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/French/ Portuguese) with external viewing window for easy indication of generator status and breaker position. • True Power m Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed • SwRi® listed (NFPA37, clause 4.1.4.1.2) Generator can be installed a minimum 18" distance from combustible wall* *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Please review install guide for more details. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA: ✓ PROTOTYPE TESTED NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY GENERAL' PROTECTOR® QS SERIES Standby Generators d Gaseous Engine Standby Power Rating Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz GENERAC Eta US QUIE�FE� embled in the USA using domertic and brelgn parts Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. GENERAC 9001: GENERAC 22.27.32.38 GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32 & 38 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather protective Ensures protection against mother nature. enclosure Electrostatically applied textured epoxy paint for added du- rability. Enclosed critical grade muf- Quiet, critical grade muffler is mounted inside the unit to fler prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. application & engineering data ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Aftercoo I ed (32 & 38 kW) Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge Crankcase Capacity (qt/I) 4/3.8 (22, 27, 32 & 38 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven Fan Speed (rpm) 1980 - 22 & 27 kW 1500 - 32 & 38 kW Fan Diameter (in/mm) 18.1/459.7 (22 & 27 kW) or 22/558.8 (32 & 38 kW) Fan Mode Pusher (22 & 27 kW) or Puller (32 & 38 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11-14" Water Column NG Fuel Pressure 5 -14" Water Column (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271) 22.27.32.38 GENERATOR OUTPUT VOLTAGEAW - 60 Hz GENERAC® operating data kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) 120/240 V,10,1.0 pf 22 92 22 92 100 RG022 120/208 V, 30, 0.8 pf 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 120/240 V,10,1.0 pf 27 113 25 104 125 RG027 120/208 V, 30, 0.8 pf 27 94 25 87 100 120/240 V, 30, 0.8 pf 27 81 25 75 90 120/240 V,10,1.0 pf 32 133 32 133 150 RG032 120/208 V, 30, 0.8 pf 32 111 32 111 125 120/240 V, 30, 0.8 pf 32 96 32 96 100 277/480 V, 30, 0.8 pf 32 48 32 48 60 120/240 V,10,1.0 pf 38 158 38 158 175 RG038 120/208 V, 30, 0.8 pf 38 132 38 132 150 120/240 V, 30, 0.8 pf 38 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf 15% 30% 120/240 V,10 55 135 RG022 120/208 V, 30 40 92 120/240 V, 30 35 80 120/240 V,10 62 170 RG027 120/208 V, 30 70 120 120/240 V, 30 61 103 120/240 V,10 75 180 120/208 V, 30 87 210 RG032 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V,10 75 180 120/208 V, 30 87 210 RG038 120/240 V, 30 75 182 277/480 V, 30 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) For megajouIe content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. ENGINE FUEL CONSUMPTION Natural Gas Propane (ft3/hr) (m3/hr) (gal/hr) (113/hr) (1/hr) Exercise cycle 42 1.2 0.44 16 1.7 25% of rated load 100 2.8 1.1 40 4.2 RG022 50% of rated load 190 5.4 2.1 75 7.8 75% of rated load 255 7.2 2.8 101 10.5 100% of rated load 316 9 3.4 125 13 Exercise cycle 42 1.2 0.44 16 1.7 25% of rated load 108 3.1 1.2 43 4.5 RG027 50% of rated load 197 5.6 2.1 78 8.1 75% of rated load 287 8.2 3.1 114 11.8 100%of rated load 359 10.2 3.9 143 14.8 Exercise cycle 79 2.2 0.8 30 3.2 25% of rated load 144 4.1 1.7 60 6.3 RG032 50% of rated load 226 6.4 2.7 97 10.3 75% of rated load 298 6.4 3.7 132 13.9 100% of rated load 375 10.6 4.6 166 17.5 Exercise cycle 83 2.3 0.9 31 3.2 25% of rated load 162 4.6 1.7 62 6.6 RG038 50% of rated load 255 7.2 2.9 103 10.8 75% of rated load 345 9.8 4 142 15 100% of rated load 437 12.4 5.2 185 19 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. GENERAC 22 . 27 . 32 9 38 ENGINE COOLING operating data 22 kW 27 kW 32 & 38 kW Air flow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 System coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 Maximum operation air temperature on radiator (°C/°F) 60/150 Maximum ambient temperature (°C/°F) 50/140 COMBUSTION REQUIREMENTS Flow at rated power (cfnVcmm) 68/1.9 68/1.9 106/3 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode` 61 61 58 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load" 70 70 64 EXHAUST Exhaust flow at rated output (cfm/cmm) 165/4.7 180/5.1 300/8.5 Exhaust temperature at muffler outlet (°C/°F) 482/900 538/1000 579/1075 ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration.................................................................................................................... 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22 & 27 kW)......................................................................................................1 % for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (32 & 38 kW)................................................................................................... 1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES Two -Line Plain Text LCD Display............................................................................................................................................ Simple user interface for ease of operation. Mode Switch: Auto..................................................................................................................................................... Automatic Start on Utility failure. 7 day exerciser Off................................................................................................................................. Stops unit. Power is removed. Control and charger still operate. Manual.................................................................................................Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds..........................................................................................................................................................10 sec standard Engine Start Sequence............................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up............................................................................................................................................................................................................................. 5 sec EngineCool-Down..........................................................................................................................................................................................................................1 min Starter Lock-out..........................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger................................................................................................................................................................................................................. Standard Automatic Voltage Regulation with Over and Under Voltage Protection........................................................................................................................................ Standard Automatic Low Oil Pressure Shutdown........................................................................................................................................................................................ Standard OverspeedShutdown....................................................................................................................................................................................................... Standard, 72 Hz HighTemperature Shutdown...................................................................................................................................................................................................... Standard OvercrankProtection.................................................................................................................................................................................................................. Standard SafetyFused.............................................................................................................................................................................................................................. Standard Failureto Transfer Protection......................................................................................................................................................................................................Standard LowBattery Protection................................................................................................................................................................................................................ Standard 50 Event Run Log.......................................................................................................................................................................................................................Standard FutureSet Capable Exerciser..................................................................................................................................................................................................... Standard IncorrectWiring Protection........................................................................................................................................................................................................ Standard InternalFault Protection..............................................................................................................................................................................................................Standard CommonExternal Fault Capability.............................................................................................................................................................................................. Standard GovernorFailure Protection....................................................................................................................................................................................................... Standard GENERAC` 22 • 27 • 32 • 38 available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from Mobile Link® 4G LTE anywhere that you have access to an Internet connection from a PC or with G0071690 Cellular Accessory any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. Kit, Adapter Mobile The Harness Adapter Kit is required to make liquid -cooled units compatible G006478-0 Link L/C (Required for QT and RG Series) with Mobile Link®. G005630-1 - 22, 27, 32 & 38 If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit kW Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. G005616-0 - 22, 27, 32 & 38 Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for kW Weather Kit extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to touch-up G005703-0 - Bisque Paint Kit the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G005656-0 - 22 & 27 kW Scheduled The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware G005984-0 - 32 & 38 kW Maintenance Kit necessary to perform complete maintenance on Generac liquid -cooled generators. G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor Monitor provides you with instant status information without ever leaving the house. G006665-0 Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, Extension Harness required for use on units 70 kW or greater. Smart Management Modules are used in conjunction with the Automatic G006873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides Module (50 Amps) additional power management flexibility not found in any other power management system. G007993-0 E-stop toggle switch for residential installs E-stop allows for immediate fuel shutoff and generator shutdown in the event to NEC2017 of an emergency. E-Stop resettable G006510-0 switch for commer- E-stop allows for immediate fuel shutoff and generator shutdown in the event cial installs to of an emergency. NEC2020 The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the Wi-Fi LP Fuel Level connected LP fuel tank. Monitoring the LP tank's fuel level is an important step G007005-0 Monitor in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY 12 GRP 26 I I NEGATIVE GROUND JVL P/N: 077483 REMOVE COVE FOR ACCESS TO RADIATOR FILL CAP 427 [16.81 EXHAUST MUFFLER - ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR 141l�- [5.6] 629.9 [24.81 CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW 48 [1.9] SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE LEFT SIDE RADIATOR DRAIN LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ROOFTOP AIR CLEANER ELEMENT LEFTSIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1040 [40.9] FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. -REAR ENCLOSURE 980 COVER PANEL [38.61 SEE NOTE 4 OVERALL HEIGHT CUSTOMERACCESS ASSEMBLY,CONTROL PANELACCESS, ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 776 [30.6] OVERALL WIDTH REARVIEW 48 [1.9] TYP 45 [1.8] TYP WEIGHT DATA ENGINE/KW ENCLOSU WEIGHT WEIGHTRE SHIPPING WEIGHT KVA MATERIAL GENSET ONLY SHIPPING SKID KG [LBS1 KG [LBS] KG [LBS] 2.4L 22KW (60HZ) SINGLE PHASE 17AKVA (50HZ) AL 410.5 [9051 30 [661 440 [9711 THREE PHASE 22KVA (50HZ) 2.4L 27KW (60HZ) SINGLE PHASE 21.6KVA (50HZ) AL 426 [9401 30 [661 456 [10061 THREE PHASE 27KVA (50HZ) 631 [24.81 -­j DOOR TYP 1580 [62.2] OVERALLLENGTH RIGHT SIDE VIEW DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR 0 0 7z 00 m N C7 O N N N N TOP VIEW I I& 45 [1.8] TYP 1380 [54.3] TYP MOUNTING SLOT CENTERS 1580 [62.2] LEFT SIDE VIEW IOTE - STUB -UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. RCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 27 [1.0 723 [28.5] TYP TYP MOUNTING SLOT CENTERS 776 [30.6] REAR VIEW DIMENSIONS: MM [INCH] 3.8] N N 00 N >v c+� O 00 0 N C7 F3 0 167 [6.6] RADIATORIEXHAUST DISCHARGE AIR (BOTH SIDES) 535 [21.11 2.5' O.D. EXHAUST - OUTLET REMOVE COVET FOR ACCESS TO RADIATOR FILL CAP AIR INTAKE (BOTH SIDES — 768 [30.2] — CENTER OF GRAVITY SEE NOTE 5 TOP VIEW BATTERY 12V, GRP 26 NEGATIVE GROUND PIN:077483 EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR FUEL LINE CONNECTIO 50 [2.0]39.4 3/4" NPT FEMALE COUPLING 1000 [39.4] LEFT SIDE VIEW LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 7 AND CENTER OF GRAVITY DIMENSIONS OIL DRAIN HOSE RIGHT SIDE RADIATOR DRAIN HOSE LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOFTOP AIR CLEANER ELEMENT RIGHT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1171[46.1] OVERALL HEIGHT 888 [35.0] OVERALL WIDTH REARVIEW WEIGHT DATA ENGINEIKW ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT MATERIAL KG [LBS] KG [LBS] KG [LBS] 2.4L 32KW AL 556 [1225] 44 [98] 600 [1323] 2.4L 38KW AL 560 [12351 441981 605 [1333] NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. REAR ENCLOSURE COVER PANEL SEE NOTE 4 CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 47 - [1.8] TYP DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, 759 [29.9] ONE LIFT OFF DOOR TYP DOOR PER SIDE OF GENERATOR m - 1857 [73.1] TYP- 1950 [76.8] OVERALL LENGTH RIGHT SIDE VIEW 58 [2.3] TYP CD >v co CD 7z N co O_ N W N go W co pr y �F 0 m Z m 31 D n 0 m Z m 30 �n O N O_ O D O O N O O CD O `G O CD 3 0 O D C CD 3 � 7 N C) D 0 2 O C) Q CD D cn l< a o. Z� o � CD cn c Cn m o IV c0 O IV O CO 3 O cCD 2 C 8 O CO 0 C o w o C m co W N w oW 0 1 rn 00 c c9 co �CD o Z3 w CD w rn � o p o 50 TYP [2.0] LEFT SIDE VIEW VECTIONS. J OPENING. 3 ACCESS COVER 'H GENERATOR) RING GENERATOR U CD O 7z to rQ O T co N O L w N w co C� G G) m Z m D n Serie Protector® QS INCLUYE: • Controlador digital multilingue con pantalla LCD de dos lineas Evolution" (ingles, espanol, frances y portugues) con ventana de visualizacion externa para indicar facilmente el estado del generador y la posicion del disyuntor. • Tecnologfa electrica True PowerT • Regulador electronico isocrono • Gabinete con ruido atenuado • Sistema cerrado de recuperacion de refrigerante • Cargador de baterfa inteligente • Mangueras resistentes al ozono y los rayos ultravioleta • Regulacion de voltaje de ± 1 % • Funcionamiento con gas natural o propano Ifquido • Garantfa limitada de 5 ahos • En la lista UL 2200 • El generador indicado en la lista SwRi® (NFPA37, clausula 4.1.4.1.2) se puede instalar a una distancia minima de 18 pulg. (457 mm) de una pared combustible* *Unicamente si se ubica lejos de puertas, ventanas y entradas de aire fresco y a menos que los c6digos locales indiquen to contrario. Revise la gufa de instalacion para obtener mas detalles. CARACTERISTICAS GENERAL' SERIE PROTECTOR® QS Generadores de reserva liquido Clasificacion de alimentacion de reserva Modelo RG022 (Aluminio - Bisque) - 22 kW 60 Hz Modelo RG027 (Aluminio - Bisque) - 27 kW 60 Hz Modelo RG032 (Aluminio - Bisque) - 32 kW 60 Hz Modelo RG038 (Aluminio - Bisque) - 38 kW 60 Hz ON.. � an�sr Cumple con los reglamentos de emisiones de la EPA 22 y 27 kW cumplen con las normas de emisiones de CANA 32 y 38 kW no se venden en CA/MA O DISENO INNOVADOR Y PRUEBAS DE PROTOTIPOS son componentes clave del O REGULACION DE VOLTAJE CON FRECUENCIA COMPENSADA DE ESTADO exito de GENERAC a la hora de "MEJORAR LA ALIMENTACION A TRAVES DEL SOLIDO. Este sistema de regulacion de vanguardia que aumenta la alimentacion DISENO". Pero eso no es todo. Un compromiso total con las pruebas de esta incorporado de manera estandar en todos los modelos Generac. Proporciona componentes, de confiabilidad, ambientales, de villa util y destruccion, ademas de una RESPUESTA RAPIDA optimizada ante las condiciones de carga cambiantes y las pruebas de las normas CSA, NEMA, EGSA correspond ientes y otras normas, le una CAPACIDAD MAXIMA DE ARRANQUE DEL MOTOR mediante la concordancia de permiten elegir los productos de GENERAC POWER SYSTEMS con la confianza de par de torsion electronica de las cargas de sobrevoltaje transitorio hacia el motor. que estos sistemas le proporcionaran un rendimiento superior. Regulacion de voltaje digital en ± 1 %. O CRITERIOS DE PRUEBA: O RESPUESTA DE SERVICIO DE UNA SOLA FUENTE de la amplia red de PROTOTIPO PROBADO ' EVALUACION NEMA MG1-22 concesionarios de Generac, quienes proporcionan conocimientos tecnicos de TORSION DEL SISTEMA PROBADA CAPACIDAD DE ARRANQUE servicio y piezas de toda la unidad, desde el motor hasta el componente electronico DEL MOTOR mas pequeno. O INTERRUPTORES DE TRANSFERENCIA GENERAC. Vida Gtil prolongada y confiabilidad son sinonimos de GENERAC POWER SYSTEMS. Un motivo para esta confianza es que la Ifnea de productos de GENERAC incluye sus propios controles y sistemas de transferencia, to que ofrece una completa compatibilidad del sistema. W1,70 GENERAC 22.27.32.38 ESPECIFICACIONES DEL GENERADOR Tipo Sfncrono Clase de aislamiento del rotor H (22 y 27 kW) o F (32 y 38 kW) Clase de aislamiento del estator H Factor de interferencia telef6nica (FIT) <50 Conductores de Salida del alternador monofasicos 4 hilos Conductores de Salida del alternador trifasicos 6 hilos Cojinetes Bola sellada Acoplamiento Disco flexible Sistema de excitaci6n Directo REGULACIUN DE VOLTAJE Tipo Electr6nica Detecci6n Monofasico Regulaci6n ± 1 % ESPECIFICACIONES DEL REGULADOR Tipo Electr6nica Regulaci6n de frecuencia Is6crona Regulaci6n de estado estable ± 0,25 % SISTEMA ELECTRICO Alternador de carga de baterfa 12 voltios 30 amperios Cargador de baterfa estatico 2,5 amperios Baterfa recomendada (no incluida) Grupo 26 (22, 27, 32 y 38 kW) Voltaje del sistema 12 voltios CARACTERISTICAS DEL GENERADOR Generador de campo giratorio para servicio pesado Se conecta directamente at motor Aumento de temperatura de funcionamiento de 216 °F (120 °C) sobre una temperatura ambiente de 104 °F (40 °C) Aislamiento clase H con clasificaci6n NEMA Aislamiento clase F con clasificaci6n NEMA Todos los modelos desarrollados a partir de prototipos completamente probados CARACTERISTICAS DEL GABINETE Gabinete de protecci6n contra Garantiza protecci6n contra las inclemencias del tiempo. la intemperie de aluminio Pintura epoxi texturada aplicada de manera electrostatica para una mayor durabilidad. Silenciador de grado crftico El silenciador de grado crftico y silencioso esta montado at contenido interior de la unidad para evitar lesiones. Pequena, compacta y Contribuye a una instalaci6n facil y atractiva. atractiva SAE Gabinete con ruido atenuado que garantiza un funcionamiento silencioso. datos de ingeniena y aplicacion ESPECIFICACIONES DEL MOTOR: 22, 27, 32 V 38 kW Marca Generac Modelo En Ifnea Cilindros 4 Desplazamiento (litros) 2,4 Diametro interior (pulg./mm) 3,41/86,5 Carrera (pulg./mm) 3,94/100 Proporci6n de compresi6n 9,5:1 Sistema de entrada de aire Con aspiraci6n natural (22 y 27 kW) o con turbocompresor/posenfriador (32 y 38 kW) Tipo de elevador Hidraulico SISTEMA DE LUBRICACIUN DEL MOTOR Tipo de bomba de aceite Engranajes Tipo de filtro de aceite Cartucho enroscable de flujo completo Capacidad del carter (qt/L) 4/3,8 (22, 27, 32 y 38 kW) SISTEMA DE ENFRIAMIENTO DEL MOTOR Tipo Corrado Bomba de aqua Accionada por correa Velocidad del ventilador (rpm) 1980 - 22 y 27 kW 1500-32y38kW Diametro del ventilador (pulg./mm) 18,1/459,7 (22 y 27 kW) o 22/558,8 (32 y 38 kW) Motlo de ventilador Propulsor (22 y 27 kW) o extractor (32 y 38 kW) SISTEMA DE COMBUSTIBLE Tipo de combustible Gas natural, vapor de propano Carburador Tiro hacia abajo Regulador de combustible secundario Estandar Solenoide de cierre de combustible Estandar Presi6n de funcionamiento del combustible 5 a 14 pulg. de columna de agua/ 9a26mmHG Presi6n de combustible de PL 11 a 14 pulg. de columna de agua/ 21 a 26 mm HG Presi6n de combustible de GN 5 a 14 pulg. de columna de agua/ 9a26mmHG (Todas las clasificaciones estan de acuerdo con las normas BS5514, IS03046, IS08528, SAE J1349 y DIN6271) 22*27.32.38 VOLTAJE DE SALIDA DEL GENERADORAW - 60 Hz kW gas PL GENERAC® datos de funcionamiento Amperios gas PL kW gas nat. Amperios gas nat. Tamano del disyuntor (ambos) 120/240 V,1 0,1,0 pf 22 92 22 92 100 RG022 120/208 V, 3 0, 0,8 pf 22 76 22 76 80 120/240 V, 3 0, 0,8 pf 22 66 22 66 80 120/240 V, 10, 1,0 pf 27 113 25 104 125 RG027 120/208 V, 3 0, 0,8 pf 27 94 25 87 100 120/240 V, 3 0, 0,8 pf 27 81 25 75 90 120/240 V,1 0,1,0 pf 32 133 32 133 150 RG032 120/208 V, 3 0, 0,8 pf 32 111 32 111 125 120/240 V, 3 0, 0,8 pf 32 96 32 96 100 277/480 V, 3 0, 0,8 pf 32 48 32 48 60 120/240 V,1 0,1,0 pf 38 158 38 158 175 RG038 120/208 V, 3 0, 0,8 pf 38 132 38 132 150 120/240 V, 3 0, 0,8 pf 38 114 38 114 125 277/480 V, 3 0, 0,8 pf 38 57 38 57 60 CAPACIDAD DE SOBREVOLTAJE TRANSITORIO EN AMPERIOS Caida de voltaje a < 0,4 pf 15% 30% 120/240 V,1 0 55 135 RG022 120/208 V, 3 0 40 92 120/240 V, 3 0 35 80 120/240 V,1 0 62 170 RG027 120/208 V, 3 0 70 120 120/240 V, 3 0 61 103 120/240 V,1 0 75 180 120/208 V, 3 0 87 210 RG032 120/240 V, 3 0 75 182 277/480 V, 3 0 36 87 120/240 V,1 0 75 180 120/208 V, 3 0 87 210 RG038 120/240 V, 3 0 75 182 277/480 V, 3 0 36 87 Nota: La tuberia de combustible debe estar dimensionada pars carga plena. Para el contenido de BTU, multiplique pie3/h x 2520 (PL) o pie3/h x 1000 (GN). Para el contenido de megajulios, multiplique m3/h x 93,15 (PL) o m3/h x 37,26 (GN). Consulte la "Hojas de datos de emisiones" para conocer el flujo de combustible CONSUMO DE COMBUSTIBLE DEL MOTOR Gas natural Propano (pie3/h) (m3/h) (gal/h) (pie3/h) (Uh) Ciclo de ejercitaci6n 42 1,2 0,44 16 1,7 25 % de la carga nominal 100 2,8 1,1 40 4,2 RG022 50 % de la carga nominal 190 5,4 2,1 75 7,8 75 % de la carga nominal 255 7,2 2,8 101 10,5 100 % de la carga nominal 316 9 3,4 125 13 Ciclo de ejercitaci6n 42 1,2 0,44 16 1,7 25 % de la carga nominal 108 3,1 1,2 43 4,5 RG027 50 % de la carga nominal 197 5,6 2,1 78 8,1 75 % de la carga nominal 287 8,2 3,1 114 11,8 100 % de la carga nominal 359 10,2 3,9 143 14,8 Ciclo de ejercitaci6n 79 2,2 0,8 30 3,2 25 % de la carga nominal 144 4,1 1,7 60 6,3 RG032 50 % de la carga nominal 226 6,4 2,7 97 10,3 75 % de la carga nominal 298 6,4 3,7 132 13,9 100 % de la carga nominal 375 10,6 4,6 166 17,5 Ciclo de ejercitaci6n 83 2,3 0,9 31 3,2 25 % de la carga nominal 162 4,6 1,7 62 6,6 RG038 50 % de la carga nominal 255 7,2 2,9 103 10,8 75 % de la carga nominal 345 9,8 4 142 15 100 % de la carga nominal 437 12,4 5,2 185 19 mdximo para fines de permisos de EPA y SCAOMD. CLASIFICACION DE RESERVA: Las clasificaciones de reserva aplican a instalaciones alimentadas por una Puente confiable del servicio publico. La clasificaci6n de reserva se aplica a distintas cargas por la duraci6n de un corte de alimentaci6n. No hay capacidades de sobrecarga para esta clasificaci6n. Las clasificaciones son conforme a la ISO-3046-1. El diseno y Ias especificaciones estan sujetos a cambios sin previo aviso. GENERAC 22.27.32.38 ENFRIAMIENTO DEL MOTOR datos de funcionamiento 22 kW 27 kW 32 y 38 kW Flujo de aire (entrada de aire que incluye alternador y aire de combustion en pie3/min / m3/min) 2400/68 2400/68 2200/62,3 Capacidad de refrigerante del sistema (gal/litros) 2,5/9,5 2,5/9,5 2,5/9,5 Disipacion del calor al refrigerante (BTU por hora/MJ por hora) 99.000/104,5 105.000/110,8 145.000/153 Temperatura maxima del aire de funcionamiento en el radiador (°F/°C) 150/60 Temperatura ambiente maxima ff/°C) 140/50 REQUISITOS DE COMBUSTION Flujo a la potencia nominal (pie3/min / m3/min) 68/1,9 68/1,9 106/3 EMISIONES ACUSTICAS Salida de ruido en dB(A) a 23 pies (7 m) con el generador en modo de ejercitacion" 61 61 58 Salida de ruido en dB(A) a 23 pies (7 m) con el generador funcionando con carga normal" 70 70 64 ESCAPE Flujo de escape en la Salida nominal (pie3/min / m3/min) 165/4,7 180/5,1 300/8,5 Temperatura del escape en la Salida del silenciador (°FPC) 900/482 1000/538 1075/579 PARAMETROS DEL MOTOR Rpm sfncronas nominales 1800 AJUSTE DE ENERGIA PARA CONDICIONES AMBIENTALES Reduccion de potencia por temperatura..........................................................................................1,65% por calla 10 °F sabre 77 °F o 3 % por calla 10 °C sobre 25 °C Reduccion de potencia por altura (22 y 27 kW).....................................................................3 % por calla 1000 pies sobre 600 pies o 1 % por calla 100 m sobre 183 m Reduccion de potencia por altura (32 y 38 kW)................................................................... 3 % por calla 1000 pies sobre 3000 pies o 1 % por calla 100 m sobre 915 m CARACTERISTICAS DEL CONTROLADOR Pantalla LCD de texto plano y dos Ifneas..................................................................................................................... Interfaz de usuario simple para una operacion facil. Interruptor de modo: Auto(Automatico)......................................................................................Arranque automatico en falla de energ(a electrica. Ejercitador de 7 d(as Off(Apagado).................................................... La unidad se detiene. Se elimina la alimentacibn. El control y cargador siguen en funcionamiento. Manual......................................................................................................... Arranque con control de arrancador, la unidad permanece encendida. Si hay una falla de energia electrica, se produce la transferencia a carga. Retardo de arranque programable entre 10 y 30 segundos...................................................................................................................................................10 s estandar Secuencia de arranque del motor.........................................................................................Arranque cfclico: 16 s encendido, 7 en descanso (duracion maxima de 90 s) Calentamientodel motor.....................................................................................................................................................................................................................5 s Enfriamientodel motor....................................................................................................................................................................................................................1 min Bloqueo del arrancador.......................................................................... El arrancador no se puede volver a arrancar hasta 5 s despues de que el motor se haya detenido. Cargadorde baterfa inteligente....................................................................................................................................................................................................Estandar Regulacion de voltaje automatica con proteccion de subvoltaje y sobrevoltaje..............................................................................................................................Estandar Desconexion automatica por baja presion del aceite.....................................................................................................................................................................Estandar Desconexion por exceso de velocidad...............................................................................................................................................................................Estandar, 72 Hz Desconexion por temperature alta............................................................................................................................................................................................... Estandar Proteccionde falla de arranque....................................................................................................................................................................................................Estandar Seguridadprotegida con fusibles.................................................................................................................................................................................................Estandar Proteccion de falla de transferencia.............................................................................................................................................................................................Estandar Proteccionde baterfa baja...........................................................................................................................................................................................................Estandar Registro de funcionamiento de 50 eventos...................................................................................................................................................................................Estandar Ejercitador con capacidad de ajuste en el futuro.......................................................................................................................................................................... Estandar Proteccion de cableado incorrecto.............................................................................................................................................................................................. Estandar Proteccionde falla interna...........................................................................................................................................................................................................Estandar Capacidadde falla externa comOn................................................................................................................................................................................................Estandar Proteccionde falla del regulador................................................................................................................................................................................................ Estandar GENERAC` 22 • 27 • 32 • 38 accesorios disponibles N.' de modelo Producto Descripcion Mobile Link de Generac le permite revisar el estado de su generador desde cualquier Accesorio para celular Mobile lugar con acceso a conexion de Internet desde una computadora o con un G0071690 Link® 4G LTE dispositivo movil. Incluso, se le notificara cuando haya un cambio en el estado del generador por correo electronico o mensaje de texto. Nota: Se requiere un kit de adaptador de mazo de cables. Disponible solo en EE. UU. G006478-0 G005630-1 - 22, 27, 32 y 38 kW Kit, adaptador Mobile Link UC (necesario para las series QT y RG) Kit para climas frios G005616-0 - 22, 27, 32 y Kit para climas extremadamente 38 kW frios G005651-0 G005703-0-Bisque Kit de tapones de base Kit de pintura G005656-0 - 22 y 27 kW Kit de mantenimiento G005984-0 - 32 y 38 kW programado El kit adaptador de mazo de cables es necesario para hacer que las unidades enfriadas por liquido sean compatibles con Mobile Link®. Si la temperatura normalmente disminuye a menos de 32 °F (0 °C), instale un kit para climas frios para mantener una temperatura optima de la bateria. El kit consta de un calentador de bateria con un termostato integrado en la envoltura. Recomendado en lugares donde la temperatura normalmente disminuye a menos de 32 °F (0 °C) por periodos prolongados. Solo para unidades enfriadas por liquido. Agregue tapones de base en la base para impedir que entren residuos al generador Si el gabinete del generador se raya o dana, es importante retocar la pintura para protegerlo contra la corrosion futura. El kit de pintura incluye la pintura necesaria para mantener o retocar adecuadamente el gabinete de un generador. Los kits de mantenimiento programado para generadores enfriados por liquido ofrecen todas las piezas metalicas necesarias para realizar un completo mantenimiento en los generadores enfriados por liquido de Generac. El monitor inalambrico de Generac, completamente inalambrico y alimentado por G006664-0 Monitor inalambrico local bateria, le proporciona informacion instantanea del estado sin necesidad de salir de casa. G006665-0 Mazo de cables de extension del Recomendado para use con el control remoto inalambrico en unidades de hasta control remoto inalambrico 60 kW, obligatorio para unidades de 70 kW o mas. Los modulos de administracion inteligente se usan en conjunto con el interruptor de G006873-0 Modulo de administracion transferencia automatica para aumentar las capacidades de administracion de inteligente (50 amperios) alimentacion. Proporciona flexibilidad de administracion de alimentacion adicional que no se encuentra en ningOn otro sistema de administracion de alimentacion. Interruptor basculante de parada G007993-0 de emergencia para La parada de emergencia permite apagar el generador y cortar el suministro de instalaciones residenciales combustible inmediatamente en caso de una emergencia. conforme a NEC2017 Interruptor con restablecimiento G006510-0 de parada de emergencia para La parada de emergencia permite apagar el generador y cortar el suministro de instalaciones comerciales combustible inmediatamente en caso de una emergencia. conforme a NEC2020 El monitor Wi-Fi de nivel de combustible PL proporciona un monitoreo constante del tanque de combustible PL conectado. El monitoreo del nivel de combustible del G007005-0 Monitor Wi-Fi de nivel de tanque de PL es un paso importante para asegurarse de que el generador este listo combustible PL para funcionar durante una interrupcion de alimentacion inesperada. Se dispone de alertas de estado por medio de una aplicacion gratuita, para proporcionar una notificacion cuando el tanque de PL requiere relleno. RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY 12 GRP26 NEGATIVE GRUNDOJVL P/N: 077483 REMOVE COVE FOR ACCESS TO RADIATOR FILL CAP 427 [16.81 EXHAUST MUFFLER - ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR 141l�— [5.6] 629.9 [24.8] CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW 48 [1.9] SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE LEFT SIDE RADIATOR DRAIN LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ROOFTOP AIR CLEANER ELEMENT LEFT SIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1040 [40.9] FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. -REAR ENCLOSURE 980 COVER PANEL [38.6] SEE NOTE 4 OVERALL HEIGHT CUSTOMERACCESS ASSEMBLY,CONTROL PANELACCESS, ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 776 [30.6] OVERALL WIDTH REARVIEW 48 [1.9] TYP 45 [1.8] TYP WEIGHT DATA ENGINE/KW ENCLOSURE WEIGHT WEIGHT SHIPPING WEIGHT KVA MATERIAL GENSET ONLY SHIPPING SKID KG [LBS1 KG [LBS] KG [LBS] 2.4L 22KW (60HZ) SINGLE PHASE 17AKVA (50HZ) AL 410.5 [9051 301661 440 [9711 THREE PHASE 22KVA (50HZ) 2.4L 27KW (60HZ) SINGLE PHASE 21.6KVA (50HZ) AL 426 [9401 30 [661 456 [10061 THREE PHASE 27KVA (50HZ) [24.8] DOOR TYP 1580 [62.2] OVERALLLENGTH RIGHT SIDE VIEW DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR m 0 �o 00 0 00 rn N I n d CD rlD TOP VIEW Aft 45 [1.8] TYP 1380 [54.3] TYP MOUNTING SLOT CENTERS 1580 [62.2] LEFT SIDE VIEW IOTE - STUB -UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. RCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 27 [1.0 [� 723 [28.5] TYP TYP MOUNTING SLOT CENTERS 776 [30.6] REAR VIEW DIMENSIONS: MM [INCH] 3.8] N N �G N 4 77 CL y, M �1 � O CD m oCDzCD mco) m 30 N � Q D 167 [6.6] RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) 535 [21.1] 2.5' O.D. EXHAUST - OUTLET REMOVE COVET FOR ACCESS TO RADIATOR FILL CAP AIR INTAKE (BOTH SIDES 768 [30.2] CENTER OF GRAVITY SEE NOTE 5 • 0" TOP VIEW BATTERY 12V, GRP 26 NEGATIVE GROUND PIN:077483 EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE f RADIATOR/EXHAUST DISCHARGE AIR C3 FUEL LINE CONNECTIO 50 [2.0] 3/4" NPT FEMALE COUPLING 1000 [39.4] LEFT SIDE VIEW LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 7 AND CENTER OF GRAVITY DIMENSIONS OIL DRAIN HOSE RIGHT SIDI RADIATOR DRAIN HOSE LEFT SIDE :OOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOF TOF AIR CLEANER ELEMENT RIGHT SIDI SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE' DRIVE BELT EITHER SID FAN BELT SEE NOTE' BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1171[46.1] OVERALL HEIGHT 888 [35.0] OVERALL WIDTH REARVIEW WEIGHT DATA ENGINEIKW ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT MATERIAL KG [LBS] KG [LBS] KG [L8S] 2.4L 32KW AL 556 [1225] 441981 600 [1323] 2.4L 38KW AL 560 [12351 44 [98] 605 [1333] NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, ONE PER DOOR, 759 [29.9] ONE LIFT OFF 7 DOOR TYP DOOR PER SIDE OF GENERATOR REAR ENCLOSURE COVER PANEL SEE NOTE 4 CUSTOMERACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 47 - [1.8] TYP DIMENSIONS: MM [INCH] i r_ 1ji - 1857 [73.1] TYP - 1950 [76.8] OVERALL LENGTH RIGHT SIDE VIEW 58 [2.3] TYP 0 �o CD 7z CD N rn co a CD N W N w co 0 m Z m 30 D n O N O_ co D (D (D N O O (D CD CD m 5 C o a, 0 C-' m � o � o_ m m cn 3 � O CD N D N CD (D _ 7 0- 0 • N o 01 a 01 IV CD CO CD IV CD a O coi 2 v 0. cTi 7 CD o CD w 77 CD m w= 0 �. m w v 031 �o 00 a CD °O' < CD o N C n O y O O � 50 TYP [2.0] LEFT SIDE VIEW VECTIONS. J OPENING. 3 ACCESS COVER 'H GENERATOR) RING GENERATOR w N w co pr _v y, CD �1 m cCD O co) m 90 N � p.F CC)30 N D CD a �. Protector® serie QS COMPREND : • Controleur numerique multilingue Evolution'" A affichage a cristaux liquides de deux lignes (anglais/ espagnol/frangais/portugais) avec fenetre externe pour observer facilement I'etat de la generatrice et la position des disjoncteurs. • Technologie electrique True Power- • Regulateur de vitesse electronique isochrone • Enceinte a attenuation sonore • Recuperation de liquide de refroidissement en circuit ferme • Chargeur de batterie intelligent • Flexibles resistant aux UV et A ('ozone • Regulation de tension A ±1 % pres • Fonctionne au gaz naturel ou au GPL • Garantie limitee 5 ans • Homologue UL 2200 • Homologue SwRi® (NFPA37, clause 4.1.4.1.2) La generatrice peut titre installee a une distance de 18 po (457 mm) minimum d'une paroi combustible* *Uniquement si place a 1'ecart des portes, des fenetres et des prises d'air frais et sauf prescriptions contraires de la reglementation en vigueur. Pour plus de details, consulter le guide d'installation. CARACTERISTIQUES O CONCEPTION INNOVANTE ET ESSAIS SUR PROTOTYPES sont des elements O essentiels de I'approche de GENERAC a « AMELIORER L'ALIMENTATION ELECTRIOUE A DESSEIN ». Mais ga ne s'arrete pas la. Notre approche exhaustive des essais de composants, essais de fiabilite, essais environnementaux, essais destructifs et de duree, en plus des essais prevus par CSA, NEMA, EGSA et d'autres normes, vous permet d'opter pour GENERAC POWER SYSTEMS avec I'assurance de resultats superieurs. O CRITERES D'ESSAI : O ✓ ESSAIS DE PROTOTYPES EVALUATION NEMA MG1-22 ESSAIS DE TORSION DU SYSTEME CAPACITE DE DEMARRAGE DU MOTEUR GENERAC' PROTECTORO SERIE OS Generatrices de secours Moteur a gaz refroidi par liquide Puissance nominale de secours Modele RG022 (aluminium - bisque) - 22 kW 60 Hz Modele RG027 (aluminium - bisque) - 27 kW 60 Hz Modele RG032 (aluminium - bisque) - 32 kW 60 Hz Modele RG038 (aluminium - bisque) - 38 kW 60 Hz flb.. Conforme aux reglementations sur les emissions de ('EPA Modeles 22 et 27 kW conformes aux normes d'emissions du CA/MA Modeles 32 et 38 kW non vendus au CA/MA REGULATION MICROELECTRONIQUE DE TENSION A FREQUENCE COMPENSEE. Ce systeme de regulation de pointe a maximisation de la puissance equipe de serie tous les moddes Generac. II fournit une REPONSE RAPIDE optimisee en fonction des variations des conditions de charge et une CAPACITE MAXIMALE DE DEMARRAGE DU MOTEUR par asservissement electronique du couple aux pointes de charge sur le moteur. Regulation numerique de la tension a ±1 % pres. SERVICE APRES-VENTE A SOURCE UNIQUE par le reseau etendu de concessionnaires Generac, qui disposent des pieces et du savoir-faire pour 1'entretien et les reparations de ('ensemble de la machine, du moteur jusqu'aux plus petits composants electroniques. O COMMUTATEURS DE TRANSFERT GENERAC. Durabilite et fiabilite sont synonymes de GENERAC POWER SYSTEMS. L'une des raisons de cette assurance est que la gamme de produits GENERAC est proposee avec ses propres dispositif et commandes de transfert, pour une compatibilite totale avec le systeme. GENERAC® 4 GENERAC® 22.27.32.38 CARACTERISTIQUES DE LA GENERATRICE Type Synchrone Classe d'isolation du rotor H (22 of 27 kW) ou F (32 et 38 kW) Classe d'isolation du stator H Facteur de perturbation telephonique (TIF) < 50 Conducteurs de sortie d'alternateur, monophase 4 conducteurs Conducteurs de sortie d'alternateur, triphase 6 conducteurs Roulements Etanches a billes Accouplement Disque flexible Systeme d'excitation Direct REGULATION DE TENSION Type Electronique Detection Monophase Regulation ± 1 % CARACTERISTIQUES DU REGULATEUR DE VITESSE Type Electronique Regulation de frequence Isochrone Regulation du regime permanent ± 0,25% SYSTEM ELECTRIQUE Alternateur de charge de batterie 12 V 30 A Chargeur de batterie statique 2,5 A Batterie recommandee (batterie non fournie) Groupe 26 (22, 27, 32 et 38 kW) Tension du systeme 12 V CARACTERISTIQUES DE LA GENERATRICE Generatrice service intensif a champ tournant Accouplement direct au moteur Montee de la temperature d'exploitation de 216 °F (120 °C) au-dessus d'une ambiante de 104 °F (40 °C) Isolation de classe H conforme a NEMA Isolation de classe F conforme a NEMA Tous les modeles sont entierement testes sur prototypes CARACTERISTIQUES DE L'ENCEINTE Enceinte en aluminium a Assure la protection contre les elements. 1'epreuve des intemperies Peinture epoxy texturee appliquee par poudrage electrostatique pour plus de durabilite. Silencieux interne de type Le silencieux tres peu bruyant de type critique est monte a critique I'interieur de 1'enceinte pour eviter les blessures. Petit, compact, attrayant Permet une installation facile et visuellement attrayante. SAE L'enceinte a attenuation sonore assure un fonctionnement peu bruyant. donnees techniques et d'utilisation CARACTERISTIQUES DU MOTEUR : 22, 27, 32 et 38 kW Marque Generac Modele En ligne Cylindres 4 Cylindree (litres) 2,4 Alesage (po/mm) 3,41/86,5 Course (po/mm) 3,94/100 Taux de compression 9,5:1 Systeme d'admission d'air Aspiration naturelle (22 of 27 kW) ou Turbo -compress i on/post-refro id issement (32 et 38 kW) Type de cames Hydrauliques SYSTEME DE GRAISSAGE DU MOTEUR Type de pompe a huile Engrenages Type de filtre a huile Cartouche vissee a debit integral Capacite d'huile du carter (pte/L) 4/3,8 (22, 27, 32 of 38 kW) SYSTEME DE REFROIDISSEMENT DU MOTEUR Type Ferme Pompe a eau Entram6 par courroie Vitesse du ventilateur (tr/min) 1980 - 22 et 27 kW 1500 - 32 et 38 kW Diametre du ventilateur (po/mm) 18,1/459,7 (22 of 27 kW) ou 22/558,8 (32 of 38 kW) Mode de ventilateur Soufflant (22 et 27 kW) ou Aspirant (32 et 38 kW) CIRCUIT DE CARBURANT Type de carburant Gaz naturel, vapeur de propane Carburateur Inverse Vapo-detendeur secondaire De serie Electrovanne de coupure de carburant De serie Pression de service du carburant 5 a 14 poH20/ 9 a 26 mmHg Pression de carburant GPL 11 a 14 poH20 Pression de carburant GN 5 a 14 poH20 (Toutes les caracteristiques nominates conformement a BS5514, IS03046, IS08528, SAE J1349 of DIN6271) 22*27.32.38 TENSION/PUISSANCE DE SORTIE DE LA GENERATRICE - 60 Hz GENERAC® donnees d'exploitation kW GPL A GPL kW Gaz nat. A Gaz nat. Disloncteur (A) (les deux) 120/240 V, mono, f. puiss.1,0 22 92 22 92 100 RG022 120/208 V, tri, f. puiss. 0,8 22 76 22 76 80 120/240 V, tri, f. puiss. 0,8 22 66 22 66 80 120/240 V, mono, I. puiss. 1,0 27 113 25 104 125 RG027 120/208 V, tri, f. puiss. 0,8 27 94 25 87 100 120/240 V, tri, f. puiss. 0,8 27 81 25 75 90 120/240 V, mono, I. puiss.1,0 32 133 32 133 150 RG032 120/208 V, tri, f. puiss. 0,8 32 111 32 111 125 120/240 V, tri, f. puiss. 0,8 32 96 32 96 100 277/480 V, tri, f. puiss. 0,8 32 48 32 48 60 120/240 V, mono, f. puiss.1,0 38 158 38 158 175 RG038 120/208 V, tri, f. puiss. 0,8 38 132 38 132 150 120/240 V, tri, f. puiss. 0,8 38 114 38 114 125 277/480 V, tri, f. puiss. 0,8 38 57 38 57 60 CAPACITE DE SURINTENSITE Creux de tension < 0,4 f. puiss. 15% 30% 120/240 V, mono 55 135 RG022 120/208 V, tri 40 92 120/240 V, tri 35 80 120/240 V, mono 62 170 RG027 120/208 V, tri 70 120 120/240 V, tri 61 103 120/240 V, mono 75 180 120/208 V, tri 87 210 RG032 120/240 V, tri 75 182 277/480 V, tri 36 87 120/240 V, mono 75 180 120/208 V, tri 87 210 RG038 120/240 V, tri 75 182 277/480 V, tri 36 87 Remarque:La conduite de carburant doit Ore de section suffisante pour la pleine charge. Pouvoir calorifique en BTU, multiplier pi3/h x 2520 (GPL) ou pi3/h x 1000 (GN) Pouvoir calorifique en MJ, multiplier m3/h x 93,15 (GPL) ou m3/h x 37,26 (GN) Voir le debit maximal de carburant Bans les , Fiches de donn6es d'6missions > pour les besoins des permis EPA et SCAQMD. CONSOMMATION DE CARBURANT DU MOTEUR Gaz nature) Propane (pia/h) (m3/h) (gal/h) (pi3/h) (1/h) Exercice d'entretien 42 1,2 0,44 16 1,7 25 % de la charge nominate 100 2,8 1,1 40 4,2 RG022 50% de la charge nominale 190 5,4 2,1 75 7,8 75% de la charge nominale 255 7,2 2,8 101 10,5 100% de la charge nominale 316 9 3,4 125 13 Exercice d'entretien 42 1,2 0,44 16 1,7 25 % de la charge nominate 108 3,1 1,2 43 4,5 RG027 50 % de la charge nominate 197 5,6 2,1 78 8,1 75 % de la charge nominate 287 8,2 3,1 114 11,8 100 % de la charge nominate 359 10,2 3,9 143 14,8 Exercice d'entretien 79 2,2 0,8 30 3,2 25 % de la charge nominale 144 4,1 1,7 60 6,3 RG032 50 % de la charge nominale 226 6,4 2,7 97 10,3 75 % de la charge nominale 298 6,4 3,7 132 13,9 100 % de la charge nominale 375 10,6 4,6 166 17,5 Exercice d'entretien 83 2,3 0,9 31 3,2 25 % de la charge nominale 162 4,6 1,7 62 6,6 RG038 50 % de la charge nominale 255 7,2 2,9 103 10,8 75 % de la charge nominale 345 9,8 4 142 15 100 % de la charge nominale 437 12,4 5,2 185 19 PUISSANCE NOMINALE DE SECOURS : Les puissances nominales de secours s'appliquent aux installations desservies par un r6seau 6Iectrique fiable. La puissance nominale de secours peut titre appliqu6e A diverses charges pendant la dur6e d'une coupure de courant. II n'y a pas de capacit6 de surcharge pour cette puissance nominate. Les caract6ristiques nominates sont en conformilb avec ISO-3046-1. La conception et les caract6ristiques sont sujettes a modification sans pr6avis. GENERAC 22.27.32.38 REFROIDISSEMENT DU MOTEUR donnees d'exploitation 22 kW 27 kW 32 et 38 kW Debit d'air (admission dont air d'alternateur et de combustion, pia/min et m3/min) 2400/68 2400/68 2200/62,3 Capacit6 du circuit de refroidissement (gal/L) 2,5/9,5 2,5/9,5 2,5/9,5 Rejet de chaleur clans liquide de refroidissement (BTU/h / MJ/h) 99 000/104,5 105 000/110,8 145 000/153 Temperature maximale d'exploitation de I'air maximum sur le radiateur (°F/°C) 150/60 Temperature ambiante maximale (°F/°C) 140/50 EXIGENCES DE COMBUSTION Debit a la puissance nominale (pia/min et m3/min) 68/1,9 68/1,9 106/3 EMISSIONS SONORES Niveau sonore en dB(A) a 23 pi (7 m) en mode d'exercice d'entretien" 61 61 58 Niveau sonore en dB(A) a 23 pi (7 m) en mode de fonctionnement a charge normale" 70 70 64 ECHAPPEMENT Debit d'echappement a la puissance nominale (pi3/min et m3/min) 165/4,7 180/5,1 300/8,5 Temperature cl'echappement a la sortie du silencieux (°F/°C) 900/482 1000/538 1075/579 PARAMETRES DU MOTEUR Ragime synchrone nominal (tr/min) 1800 AJUSTEMENT DE PUISSANCE EN FONCTION DES CONDITIONS AMBIANTES Reduction de charge en temperature........................................................................1,65% tous les 10 °F au-dessus fie 77 °F ou 3 % tous les 10 °C au-dessus de 25 °C Reduction de charge en altitude (22 et 27 kW) ..................................................... 3 % tous les 1000 pi au-dessus de 600 pi ou 1 % tous les 100 m au-dessus de 183 m Reduction de charge en altitude (32 et 38 kW)....................................................3 % tous les 1000 pi au-dessus de 3000 pi ou 1 % tous les 100 m au-dessus de 915 m CARACTERISTIOUES DU CONTROLEUR Afficheur a cristaux liquifies a deux lignes de texte............................................................................................................................Interface utilisateur simple d'emploi. Commutateur de mode : Auto......................................................................... Demarrage automatique en cas de panne du reseau electrique. Exercice d'entretien 7 jours Off (Desactive)................................... Met la generatrice a I'arret. Le courant est coupe. La commanfie et le chargeur continuent fie fonctionner. Manual (Manuel)................................................................................. Demarrage par commanfie de d6marreur, la generatrice reste en marche. En cas de panne de reseau, le transfert fie charge s'effectue. Delai de Demarrage programmable de 10 a 30 secondes......................................................................................................................................................10 s de serie Sequence de demarrage du moteur.................................................................................................Cycle fie lancement :16 s active, 7 s de repos (duree maximale 90 s) Prechauffagedu moteur.......................................................................................................................................................................................................................5 s Refroidissementdu moteur..............................................................................................................................................................................................................1 min Verrouillage du demarreur.......................................................................................................Le demarreur ne peut pas We relance pendant 5 s apres I'arret du moteur. Chargeurde batterie intelligent.................................................................................................................................................................................................... De serie Regulation de tension automatique avec protection contre les surtensions et les sous-tensions .................................................................................................... De serie Arret automatique pour basse pression d'huile............................................................................................................................................................................. De serie Arretpour surregime......................................................................................................................................................................................................... De serie, 72 Hz Arretpour temperature elevee..................................................................................................................................................................................................... De serie Protectioncontre 1'emballement.................................................................................................................................................................................................. De serie Fusiblede securite...................................................................................................................................................................................................................... De serie Protection contre les echecs du transfert...................................................................................................................................................................................... De serie Protectionbatterie dechargee...................................................................................................................................................................................................... De serie Journalde fonctionnement 50 evenements.................................................................................................................................................................................. De serie Systeme d'exercice d'entretien compatible futur groupe.............................................................................................................................................................. De serie Protection contre les cablages incorrects.................................................................................................................................................................................... De serie Protection contre les defaillances internes................................................................................................................................................................................... De serie Capacite defaillances externes courantes..................................................................................................................................................................................... De serie Protection contre les defaillances du regulateur fie vitesse.......................................................................................................................................................... De serie GENERAC` 22 • 27 • 32 • 38 accessoires disponibles N° de modele Produit Description Le systeme Mobile Link de Generac permet de controler 1'etat de la generatrice depuis Accessoire cellulaire tout endroit ayant acces a une connexion Internet a partir d'un ordinateur ou de tout G0071690 4G LTE Mobile Link® telephone intelligent. 11 permet meme d'etre notifie par courriel ou SMS de tout changement se produisant dans 1'etat de la generatrice. Remarque : Necessaire faisceau adaptateur requis. Propose aux Etats-Unis seulement. Necessaire adaptateur G006478-0 Mobile Link L/C (requis Le necessaire faisceau adaptateur est requis pour rendre Ies modeles refroidis par pour Ies series QT et Iiquide compatibles avec Mobile Link®. RG) Necessaire pour temps Si la temperature descend regulierement en dessous de 32 °F (0 °C), installer un G005630-1 - 22, 27, 32 et 38 kW froid necessaires pour temps froid afin de maintenir la batterie a une temperature optimale. Le necessaire comprend un chauffe-batterie a thermostat integre Bans 1'enveloppe. G005616-0 - 22, 27, 32 et 38 kW Necessaire pour froid Recommande si la temperature descend regulierement en dessous de 32 T (0 °C) extreme pendant des durees prolongees. Pour Ies modeles refroidis par Iiquide uniquement. G005651-0 Necessaire bouchons L'ajout de bouchons sur le socle de la generatrice permet d'empecher ('intrusion de de socle saletes. Si 1'enceinte de la generatrice est rayee ou endommagee, it est important de retoucher G005703-0 - Bisque Necessaire de peinture la peinture pour la proteger contre la corrosion. Le necessaire de peinture comprend la peinture requise pour assurer un entretien ou une retouche correcte de 1'enceinte de generatrice. G005656-0 - 22 et 27 kW Necessaire d'entretien Les necessaires d'entretien courants pour modeles refroidis par Iiquide comprennent G005984-0 - 32 et 38 kW courant tout le materiel necessaire pour effectuer des operations d'entretien completes sur Ies generatrices Generac refroidies par Iiquide. G006664-0 Systeme local de Alimente par batterie, le systeme de surveillance sans fil de Generac permet d'etre surveillance sans fil informe en temps reel de 1'etat de la generatrice sans jamais sortir de la maison. G006665-0 Faisceau de rallonge de Utilisation recommandee avec la telecommande sans fil sur Ies modeles jusqu'a telecommande sans fil 60 kW, obligatoire sur Ies modeles de 70 kW ou plus. Les modules de gestion intelligente s'utilisent en association avec le commutateur de G006873-0 Module de gestion transfert automatique pour renforcer ses capacites de gestion de I'energie. Its off rent intelligente (50 A) une souplesse supplementaire clans la gestion de 1'energie sans egale parmi Ies autres systemes sur le marche. Interrupteur a bascule G007993-0 d'arret d'urgence pour installations L'arret d'urgence permet cle couper I'arrivee cle carburant et d'arreter la generatrice residentielles selon immediatement en cas d'urgence. NEC2017 Interrupteur d'arret G006510-0 d'urgence rearmable pour installations L'arret d'urgence permet cle couper I'arrivee cle carburant et d'arreter la generatrice commerciales selon immediatement en cas d'urgence. NEC2020 Le controleur de niveau de propane compatible Wi-Fi permet une surveillance en Controleur de niveau de continu du reservoir de propane Iiquide raccorde. La surveillance du niveau du reservoir G007005-0 propane Iiquide Wi Fi est un moyen important d'assurer que la generatrice sera prete a I'emploi durant une coupure de courant inattendue. Alerte d'etat au moyen d'une application gratuite pour vous avertir Iorsqu'il Taut refaire le plein du reservoir. RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY 12 GRP26 NEGATIVE GRUNDOJVL P/N: 077483 REMOVE COVE FOR ACCESS TO RADIATOR FILL CAP 427 [16.81 EXHAUST MUFFLER - ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR 141l�- [5.6] 629.9 [24.8] CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW SERVICE ITEM 2.4L OIL FILL CAP EITHER SIDE OIL DIP STICK RIGHT SIDE OIL FILTER RIGHT SIDE OIL DRAIN HOSE LEFT SIDE RADIATOR DRAIN LEFT SIDE COOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ROOFTOP AIR CLEANER ELEMENT LEFTSIDE SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE 11 DRIVE BELT EITHER SIDE FAN BELT SEE NOTE 11 BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1040 48 [40.9] [1.9] FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. -REAR ENCLOSURE 980 COVER PANEL [38.6] SEE NOTE 4 OVERALL HEIGHT CUSTOMERACCESS ASSEMBLY,CONTROL PANELACCESS, ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 776 [30.6] OVERALL WIDTH REARVIEW 48 [1.9] TYP 45 [1.8] TYP WEIGHT DATA ENGINE/KW ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT KVA MATERIAL KG [LBS] KG [LBS] KG [LBS1 2.4L 22KW (60HZ) SINGLE PHASE 17AKVA (50HZ) AL 410.5 [9051 301661 440 [9711 THREE PHASE 22KVA (50HZ) 2.4L 27KW (60HZ) SINGLE PHASE 21.6KVA (50HZ) AL 426 [9401 30 [661 456 [10061 THREE PHASE 27KVA (50HZ) [24.8] DOOR TYP 1580 [62.2] OVERALLLENGTH RIGHT SIDE VIEW DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR 0 CD Tn 0 0 0 00 0 rn N cD C1 CD L N N CD 0-0 pr TOP VIEW Aft 45 [1.8] TYP 1380 [54.3] TYP MOUNTING SLOT CENTERS 1580 [62.2] LEFT SIDE VIEW IOTE - STUB -UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. RCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 27 [1.0 723 [28.5] TYP TYP r; MOUNTING SLOT CENTERS 776 [30.6] REAR VIEW DIMENSIONS: MM [INCH] 3.8] u CD N N 0 O 7z m IV N fs CD IV N N CD N 167 [6.6] RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) 535 [21.1] 2.5' O.D. EXHAUST - OUTLET REMOVE COVET FOR ACCESS TO RADIATOR FILL CAP AIR INTAKE (BOTH SIDES 768 [30.2] CENTER OF GRAVITY SEE NOTE 5 • 0" TOP VIEW BATTERY 12V, GRP 26 NEGATIVE GROUND PIN:077483 EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE f RADIATOR/EXHAUST DISCHARGE AIR 0 50 [2.0] FUEL LINE CONNECTIO 39.4 3/4" NPT FEMALE COUPLING 1000 [39.4] LEFT SIDE VIEW LIFTING PROVISIONS (4 PLACES) SEE NOTES 5, 7 AND CENTER OF GRAVITY DIMENSIONS OIL DRAIN HOSE RIGHT SIDI RADIATOR DRAIN HOSE LEFT SIDE :OOLANT RECOVERY BOTTLE LEFT SIDE RADIATOR FILL CAP ACCESS ROOF TOF AIR CLEANER ELEMENT RIGHT SIDI SPARK PLUGS LEFT SIDE MUFFLER SEE NOTE' DRIVE BELT EITHER BID FAN BELT SEE NOTE' BATTERY LEFT SIDE REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1171[46.1] OVERALL HEIGHT 888 [35.0] OVERALL WIDTH REARVIEW WEIGHT DATA ENGINEIKW ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT MATERIAL KG [LBS] KG [LBS] KG [L8S] 2.4L 32KW AL 556 [1225] 441981 600 [1323] 2.4L 38KW AL 560 [12351 44 [98] 605 [1333] NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, ONE PER DOOR, 759 [29.9] ONE LIFT OFF 7 DOOR TYP DOOR PER SIDE OF GENERATOR REAR ENCLOSURE COVER PANEL SEE NOTE 4 CUSTOMERACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 47 - [1.8] TYP DIMENSIONS: MM [INCH] i r_ 1ji - 1857 [73.1] TYP - 1950 [76.8] OVERALL LENGTH RIGHT SIDE VIEW 58 [2.3] TYP 0 co cN N 0 0 CD co 00 00 W d cD L W N CD �F W co pir ►� a2 c9 O 0 m Z m 30 D n O N C. co D (D (D N O 0 O CD CD N CD 3 � 3 C-3 0 Q C) � O cn C � fn � Q CD O � CA N 7 m Z vD o al C alC N C N cD to O N 0 to CD m CD c � coCD UD C cn CD =r —( w 0 3 cn oQ 1 o co _. � v COo . K N CD rn N c�D N O' C) o< o 0. 50 TYP [2.0] LEFT SIDE VIEW VECTIONS. J OPENING. 3 ACCESS COVER 'H GENERATOR) RING GENERATOR C) CD cn N 0 CD CD Na m 90 co N a m w N CD w co M, m z m 30 D n