Loading...
REVIEWED BLD2024-0351+MANUF SPECS+2.13.2024_2.00.49_PM+4057368Job Name: Gensco stock TR E® Unit Prepared YHC 47E4RMAOP 0 Quantity: 1 Trane Precedent Gas/Electric Packaged Rooftop Application Unit Size Ir'-3upply Fan 1jr External Dimensions External Airflow Static Height Width DX cooling, 4 Ton 17 Pressure gas heat SEER (047) 1600 cfm 0.5H 20in 3.41 ft 4.44 ft Condenser coil protection Std condenser coil w/hail guard oltage/phase/hertz 460/60/3 - MCA 14.00 A - MOP 20.00 A W (WRY Operating Weight 0 Length Minimum Maximum 7.39 ft 725.0 lb 976.0 lb Unit Controls Microprocessor controls Entering Dry Bulb 80.00 F Entering Wet Bulb 67.00 F Ambient Temp 95.00 F Leaving Coil Dry Bulb 58.46 F Leaving Coil Wet Bulb 56.78 F Leaving Unit Dry Bulb 59.58 F Leaving Unit Wet Bulb 57.21 F Refrigeration System Options Leaving Dew Point 55.69 F Heat Type Gas Heat Heating Stages 1 Output Heating Capacity 64.00 MBh _ Output Heating Capacity with Fan 65.35 MBh Heating EAT 70.00 F Heating LAT 107.30 F Heating Temp Rise 37.30 F 92�•� Indoor Fan Data Type FC Centrifugal Drive Type Direct Evap Fan FLA 0.00 A Indoor Fan Performance Airflow 1600 cfm Design ESP 0.500 in H2O Component SP 0.000 in H2O Total SP 0.500 in H2O Supply Motor Horsepower 1.000 hp Indoor Motor Operating Power 0.44 bhp Indoor Motor Power 0.33 kW Indoor RPM 765 rpm Compressor Sect Power 3.08 kW L Circuit 1 RLA 6.40 A Circuit 2 RLA 0.00 A EER IEER/SEER Elevation 13.00 17.50 Capacity Gross Total 50.50 MBh Gross Sensible 37.22 MBh Net Total 49.15 MBh Net Sensible 35.87 MBh Fan Motor Heat 1.35 MBh Refrig Charge -circuit 1 10.8 lb Outdoor Fan Data Type Propeller Fan Quantity 1 Drive Type Direct Outdoor Fan Performance Outdoor Motor Power 0.34 kW Condenser Fan FLA 1.00 A 2023/03/22 09:43:59 Page 1 of 9 Job Name: Gensco stock TR E® Unit Prepared YHC 47E4RMAOP 0 Quantity: 1 Sound Path �I 125 Hz 2023/03/22 09:43:59 Page 2 of 9 0 rRavF Job Name: Gensco stock Prepared For: Gensco stock Unit Tag: YHC047E4RMAOP Quantity: 1 EVAPORATOR SECTION ACCESS CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE — 41 /4" --" �-� \lloq�, , 1/2" NPT GAS CONNECTION (80MBH & 120MBH) 3/4" NPT GAS CONNECTION (150MBH, 200MBH & 250MBI THROUGH THE BASE CONDENSATE E275I8"---{ 4 1/8" I I I I I I I I I I I I I I I I I I I I 1 33" 1 1 32118" 1 I SUPPLY I I RETURN I I 1 I I 4" 17 1/2' 9 7/8" 17 112" [ 3 5/8" PLAN VIEW UNIT DIMENSION DRAWING RETURN $21/4" SU PPLY 23 718' 1 O 00 4 3l4" 19 1/4" 9 3/8" 16 3/4" 3 7/8" CONDENSATE 0 TOP PANEL 40 PACKAGED GAS / ELECTRICAL DIMENSION DRAWING CONDENSER FAN COIL —UNIT CONTROL WIRE 7/8" DIA HOLE (VICE GAUGE PORTACCESS 1 3/8" DIA HOLE POWER WIRE COMPRESSOR ACCESS PANEL NOTES: 1. THRU THE -BASE ELECTRICALAND GAS IS NOT STANDARD ON ALL UN ITS. 2. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION HORIZONTAL AIR FLOW 2023/03/22 09:43:59 Page 3 of 9 Job Name: Gensco stock TRAINS® Unit Prepared YHC047E4RMAOP Quantity: 1 ELECTRICAL/ GENERAL DATA GENERAL (2)(4)(6) HEATING PERFORMANCE Model: YHC047E Oversized Motor HEATING - GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Primary Voltage: Unit Primary 460 MFS: N/A Model: Medium Media Unit Secondary Voltage — MCB: N/A Heating Input (BTU): 80,000 Unit Hertz: 60 Heating Output (BTU): ,000 Unit Phase: 3 No. Burners: 2 No. Stages 1 13.0/17.5 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA: 14.0 MCA: N/A Natural Gas (Mn/Max): 4 1/2"/14" MFS: 20.0 MFS: N/A LIP (Mn/Max) 11"/14" MCB: 20.0 MCB: N/A Gas Pipe Connection Size: 12" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number 1 Number: Number: N/A Horsepower: 1.0 Horsepower. Horsepower. N/A Motor Speed (RPM): -- Motor Speed (RPM). Motor Speed (RPM): N/A Phase 1 Phase Phase N/A Full Load Amps: 4.7 Full Load Amps: Full Load Amps: N/A Locked RotorAmps: Locked RotorAmps: Locked RotorAmps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number. 1 Horsepower: 3.6 Horsepower: 0.40 Phase: 3 Motor Speed (RPM). 1075 Rated Load Amps: 6.4 Phase. 1 Locked RotorAmps: - Full Load Amps: 1.0 POWER EXHAUST ACCESSORY (37) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit#1 10.8lb Full Load Amps: N/A Recommended 16"x25"x2" Circuit#2 N/A Locked RotorAmps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. Fora more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. 7. Installation ofthis powerexhaust kit will affect unit level MCA and could affect MOP sizing having a direct impact on existing field wiring and unit protection devices. The change in MCA/MOP is the sole responsibility of the field installing party. Trane will not issue new nameplates as a result of this power exhaust accessory installation. FLAof the powerexhaust kid option must be added to the MCA of the unit forbuilding supplyconductor sizing determination. 2023/03/22 09:43:59 Page 4 of 9 Job Name: Gensco stock TR E® Unit Prepared YHC 47E4RMAOP 0 Quantity: 1 PACKAGED GAS / ELECTRICAL CORNER WEIGHT 101 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER MAN UAL O UTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAUGAS (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD 20.0lb SMOKE DETECTOR, SUPPLY/RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REH EAT ROOF CURB BASIC UNrl-WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET OA 238.OIb O 148.0 Ib (E) LENGHT (F) WIDTH 858.0Ib 783.OIb BO 200.OIb O 178.OIb 40' 23' NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Referto unit nameplate and installation guide for weights before scheduling transportation and installation of unf. 5. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/- 10 % of the nameplate weight. . 6. Verify weight, connection, and all dimension with installer documents before installation 7. Comerweights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field . installed accessories. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY 2023/03/22 09:43:59 Page 5 of 9 Job Name: Gensco stock TR E® Unit Prepared YHC 47E4RMAOP 0 Quantity: 1 CLEARANCE 36" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPEN IN UNff OUTLINE — PACKAGED GAS/ELECTRIC CLEARANCE 46" 88 5/8" PACKAGED GAS / ELECTRIC DOWNFLOWTYPICAL ROOF OPENING CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 48" CLEARANCE 36" 46" 53 1/4" 2023/03/22 09:43:59 Page 6 of 9 Job Name: Gensco stock _ ® Prepared For: Gensco stock TRAIVE Unit Tag: YHC047E4RMAOP Quantity: 1 General (Precedent 17 Plus) The units shall be convertible airflow. The operating range shall be between 1250F and 0°F incooling as standard from the factory for units with microprocessor controls. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil. faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8", foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors (Precedent 17 Plus) All units shall have direct -drive and hermetic type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included. Two -stage compressor is outstanding for humidity control and light load cooling conditions. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8'/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7'/2 to 8'/z (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Indoor Fan (Precedent 17 Plus) All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. 2023/03/22 09:43:59 Page 7 of 9 Job Name: Gensco stock Preared For: Gensco stock rJMME® UnitTag: YHC047E4RMAOP Quantity: 1 Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual -sloped, removable and reversible condensate drain pan with through -the -base condensate drain is standard. Tool -less Hail Guards Tool -less, hail protection quality coil guards are available for condenser coil protection. Controls (Precedent 17 Plus) Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) 2023/03/22 09:43:59 Page 8 of 9 Job Name: Gensco stock TRAIV6® Unit Prepared YHC047E4RMAOP Quantity: 1 Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50°F before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). ***ATTENTION*** For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. Sequence of Operation (if applied in a SINGLE -ZONE CONSTANT -VOLUME SYSTEM or a CHANGEOVER BYPASS SYSTEM) 1. OCCUPIED HEAT/COOL: The RTU shall operate the supply fan continuously and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing to maintain zone temperature at setpoint. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: The RTU shall operate the supply fan and modulate (or cycle) compressors or modulate (or stage) heat to raise/lower zone temperature to its occupied setpoint. The OA damper shall remain closed, unless economizing. D. CHANGEOVER BYPASS SYSTEM 1. OCCUPIED HEAT/COOL: Each VAV terminal shall use pressure -independent control, with airflow measurement, to vary primary airflow to maintain zone temperature at its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors or modulate (or stage) heat based on current zone cooling/heating demands. The OA damper shall remain closed, unless economizing. 3. COOLING/HEATING CHANGEOVER LOGIC: The System Controller shall determine the overall system cooling/heating mode based on "voting" from each zone. When the majority of zones require cooling, the RTU shall operate in cooling mode and any zone that requires heating shall reduce primary airflow to minimum. When the majority of zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall reduce primary airflow to minimum. 2023/03/22 09:43:59 Page 9 of 9