Loading...
BLD2023-1329+Interior_Lighting_Summary+10.23.2023_6.12.19_PM+3856454LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: C2023 NEEA, All rights reserved Project & Applicant Information Project Title Kidstrong - 2018 WSEC For Building Department Use: I Date: Oct 24, 2023 Project Address 22315 Highway 99 Edmonds, WA 98026 Applicant Name Dina Rosas Applicant Phone 480-719-0790 Applicant Email dinar@drosas.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Entmt/Assembly, Gymnasium Building Cond. Floor Area 4,014 General Project Types Tenant Spaces — First Build Out New Building or Addition Lighting Scope g g P Interior Lighting Alteration Lighting Scope Project Cond. Floor Area 4,014 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Lighting Project Description Lighting Compliance Scope g g P P Project Type ] YP Interior / Exterior (interior includes both interior &parking Laminaire Replacement Scope P P Compliance Method P LPA Calculation Adjustment Compliance Verification P and Method Tenant Spaces — First Build Out I Interior Lighting Building area I No Calculation Adjustments selected I COMPLIES ProjeOM009 Kidstrong - 2018 WSEC Lighting Power Calculation TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING L Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x I) Total Proposed Watts By Building Area Compliance Status by Building Area 1 Exercise center 1 4,014 1 0.67 1 2,689 1,811 COMPLIES Proposed Lighting Power Density Watts per Total Watts Fixture Type/Appilcadon Fixture ID Building Area New or Quantity of Fixtures, CLDs or Fixture, CLD or Total Linear Watts per Linear Proposed Existing -to -Remain Luminaires (#F) Luminaire (WpF) Feet (LF) Foot (WpLF) OF x WpF) or (LF x WpLF) Individual Fixtures Troffer D Exercise center New 4 31 122 Recessed downlight - Exercise center Existing 4 20 80 Suspendedl A I Exercise center New 16 77 1,229 Suspended B Exercise center New 19 20 380 Project Title Kidstrong - 2018 WSEC Date Oct 24, 2023 Proposed Fixtures Details TENANT SPACES —FIRST BUILD OUT - INTERIOR LIGHTING kL Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Troffer D A-3 LED Exercise center New Fixture Description: general lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight -I A-3 LED Exercise center Existing Fixture Description: general lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended A I A-3 LED Exercise center New Fixture Description: general lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended B I A-3 LED Exercise center New Fixture Description: general lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required