APPROVED BLD RESUB1 BLD2024-0190+Mechanical_Plan+3.18.2024_2.54.21_PM+4142118MECHANICAL ABBREVIATIONS
MECHANICAL LEGEND
CD
CEILING DIFFUSER
SA
SUPPLY AIR
FLEXIBLE DUCT
RA
RETURN AIR
WB
WET BULB
OA
OUTSIDE AIR
RETURN/EXHAUST DUCT VERTICAL
LAT
LEAVING AIR TEMPERATURE
EAT
EXTERNAL AIR TEMPERATURE
E.S.P.
EXTERNAL STATIC PRESSURE (IN W.C.)
®
SUPPLY DUCT VERTICAL
WC
WATER COLUMN
EA
EXHAUST AIR
8"0
ROUND DUCT
AFF
ABOVE FINISHED FLOOR
DB
DRY BULB
FLR
FLOOR
1OX8
NEW DUCT (WIDTH X DEPTH)
RL
REFRIGERANT LIQUID
IRS
REFRIGERANT SUCTION
HP
HORSEPOWER
FLEXIBLE CONNECTION
CFM
CUBIC FEET PER MINUTE
FC
MBH
THOUSAND BTU PER HOUR
BTU
BRITISH THERMAL UNIT
EF
EXHAUST FAN
MANUAL VOLUME DAMPER
FC
FAN COIL
VD
CU
CONDENSING UNIT
SEER
SEASONAL ENERGY EFFICIENCY RATING
PVC
POLYVINYL CHLORIDE CONDUIT
SPIN IN W/ DAMPER & SCOOP
SUPPLY
14X10
10X10
TRANSITION
FIRE DAMPER
FD
CEILING RADIATION DAMPER
CRD
SIDEWALL SUPPLY DIFFUSER
SIDEWALL RETURN AIR GRILLE
® SUPPLY DIFFUSER CEILING MOUNTED
zRETURN DIFFUSER/REGISTER
OT S THERMOSTAT
O THERMOSTATIC SENSOR
EF EQUIPMENT TAG (TYPE IS ON TOP AND
1 NUMBER IDENTIFIER ON BOTTOM)
A DIFFUSER TAG (TYPE IS ON TOP AND CFM
50 IS ON BOTTOM)
SD SMOKE DETECTOR
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
MECHANICAL NOTES AND SPECIFICATIONS
1. THE CONTRACTOR SHALL PROVIDE A COMPLETE HVAC SYSTEM WHICH INCLUDES ALL LABOR, MATERIALS
TOOLS, AND EQUIPMENT FOR A COMPLETE AND FUNCTIONAL SYSTEM AND ALL NECESSARY
APPURTENANCES CUSTOMARILY INCLUDED IF NOT SPECIFICALLY CALLED OUT.
2. DEVIATION FROM MATERIALS, METHODS AND PROCEDURES SET FORTH HEREIN MUST BE APPROVED IN
WRITING. APPROVAL WILL NOT BE GIVEN UNLESS THE PROPOSED SYSTEM IS EQUAL IN PERFORMANCE,
DURABILITY LONGEVITY, AND RELIABILITY TO THAT SPECIFIED.
3. ALL INSTALLATIONS SHALL CONFORM TO THE WASHINGTON STATE BUILDING CODE
WITH THE LATEST AMENDMENTS, THE WASHINGTON STATE MECHANICAL CODE WITH
THE LATEST AMENDMENTS, THE WASHINGTON STATE FUEL GAS CODE WITH THE
LATEST AMENDMENTS, THE WASHINGTON STATE ENERGY CONSERVATION CODE WITH
AMENDMENTS AND NFPA 90A. FOR ALL MECHANICAL CODES AND INFORMATION REFER TO
ARCHITECTURAL DRAWINGS A-1.
4. SUBMISSION OF A BID OR PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR
HAS BECOME FAMILIARIZED WITH THE PLANS, SPECIFICATIONS, AND BUILDING SITE. CLAIMS MADE
SUBSEQUENT TO BIDS FOR MATERIALS AND/OR LABOR DUE TO DIFFICULTIES ENCOUNTERED WILL NOT
BE RECOGNIZED, UNLESS DIFFICULTIES COULD NOT HAVE BEEN FORESEEN EVEN THOUGH PROPER
EXAMINATION HAD BEEN MADE.
5. SHOULD ANY EQUIPMENT FURNISHED BY THE CONTRACTOR DIFFER FROM BASE ITEMS INDICATED OR
SPECIFIED HEREIN, WHICH MAY REQUIRE ADDED COST TO THE OTHER TRADES, IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO ASSUME THE COST INVOLVED.
6. UNLESS "APPROVED EQUAL" IS SPECIFICALLY STATED, BIDS SHALL BE BASED ON THE EQUIPMENT
NAMED ON DRAWINGS AS "BASE" OR "EQUAL" PRODUCTS. RTU'S, EXHAUST FANS ARE LIMITED TO
CORPORATE APPROVAL
7. "EQUAL PRODUCT" AND "APPROVED EQUAL" ITEMS LISTED SHALL CONFORM TO SPECIFIED BASE ITEMS
AND SHALL BE SUBSTANTIALLY EQUAL IN WEIGHT, CONSTRUCTION, AND CAPACITIES.
RTU'S, EXHAUST FANS ARE LIMITED TO CORPORATE APPROVAL.
8. THE CONTRACTOR SHALL REVIEW STRUCTURAL DRAWINGS BEFORE FABRICATING OR INSTALLING
DUCTWORK OR EQUIPMENT TO AVOID ANY CONFLICTS.
9. ALL DUCT SHALL BE AIRTIGHT, FREE OF LEAKS, MEET ENERGY CODE COMPLIANCE AND SHALL BE
INSPECTED FOR LEAKS PRIOR TO INSTALLATION OF FINISHED CEILING SYSTEM.
10. DUCTWORK, DAMPERS, LOWERS, AND OTHER DISTRIBUTION EQUIPMENT AND MATERIALS SHALL
CONFORM TO THE FOLLOWING:
A. ASHRAE/ANSI E. AMCA STANDARD HANDBOOK 99
B. SBCCl/ASME F. AIR DIFFUSION COUNCIL TEST CODE 1062R3
C. SMACNA G. ANY LOCAL CODES NOT COVERED ABOVE
D. NFPA
11. ALL DUCT SIZES ARE CLEAR NET INSIDE DIMENSIONS. WHERE INTERNAL INSULATION IS CALLED FOR,
DIMENSIONS SHALL BE INCREASED BY THE THICKNESS OF THE INSULATION.
12. FLEXIBLE DUCTWORK SHALL BE CLASS 1, UL 181 WITH A MINIMUM R VALUE OF R-6, SAME SIZE AS
DIFFUSER NECKS. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE, AND SHALL
BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS.
MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 48".
13. SHEET METAL SUPPLY, RETURN, & OA DUCTWORK IN NON -AIR CONDITIONED AREAS AND MECHANICAL
ROOMS SHALL BE INSULATED WITH 2" THICK FIBERGLASS DUCT INSULATION WITH FOIL VAPOR
BARRIER, U.L. ISTED, MINIMUM R-6.
14. ALL LOW PRESSURE ROUND DUCT SHALL BE CONNECTED TO LOW PRESSURE DUCT WITH SPIN -IN
FITTINGS WITH 45' EXTRACTOR AND ADJUSTABLE MANUAL DAMPERS.
NOTE:
HVAC CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL
OF THE FOLLOWING ITEMS:
- NEW ROOFTOP UNITS
- SUPPLY AND RETURN DUCTWORK
- REGISTERS AND DIFFUSERS
- EXHAUST FANS
ANY EQUIPMENT INSTALLED WITHOUT APPROVAL WILL BECOME THE
CONTRACTORS RESPONSIBILITY IF REJECTED BY THE BUIDLING DEPARTMENT
FINAL INSPECTION, AND OR REVIEWED BY THIS OFFICE.
AT THE COMPLETION OF THE HVAC SYSTEM THE MECHANICAL CONTRACTOR SHALL
FURNISH A AIR BALANCE REPORT SIGNED AND SEALED BY A PROFESSIONAL ENGINEER.
15. PROGRAMMABLE THERMOSTATS SHALL BE INSTALLED AT 4'-0" AFF
16. THE ENGINEER RESERVES THE RIGHT TO DIRECT THE REMOVAL OF ANY ITEM WHICH, IN HIS OPINION,
DOES NOT PRESENT AN ORDERLY AND REASONABLY NEAT OR WORKMANLIKE APPEARANCE. SUCH
REMOVAL AND REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE ENGINEER, AT THE
CONTRACTOR'S EXPENSE, AND WITHOUT ADDITIONAL COST TO THE OWNER.
17. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, ETC.
TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING
OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN
PERMISSION FROM THE ARCHITECT.
18. ALL REFRIGERANT PIPING SHALL BE COPPER TUBING, TYPE L, HARD DRAWN, ASTM B88-1988a, LONG
RADIUS FITTINGS AND BRAZED JOINTS. JOINTS SHALL NOT BE LOCATED WITHIN WALLS OR OTHER
CONCEALED SPACES.
19. ALL REFRIGERANT PIPING TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS. ALL
SUCTION LINES SHALL BE INSULATED WITH SEAMLESS CLOSED CELL ELASTOMERIC INSULATION, 3/4"
THINK MINIMUM.
20. THE ENTIRE REFRIGERANT PIPING SYSTEM SHALL COMPLY WITH ANSI/ASHRAE STANDARD 15.
21. ALL INSULATING MATERIALS SHALL HAVE A COMPOSITE FLAME SPREAD OF 25 AND SMOKE DEVELOPED
OF 50 (ASTM E-84, NFPA 255 & UL 723).
22. PROVIDE FLEXIBLE CONNECTION WHERE DUCT CONNECTS TO AIR CONDITIONER OR FURNACE.
23. ALL PIPE PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL BE FULLY SEALED AND FIRE CAULKED
WITH UL LISTED SEALANT. ALL PIPE PENETRATIONS SHALL CONFORM WITH APPROPRIATE FIRE RATED
ASSEMBLY METHOD AS PER 2005 U.L. FIRE RESISTANCE DIRECTORY AND LOCAL AHJ.
24. BALANCE ALL AIR SYSTEMS TO ACHIEVE THE VOLUME AND QUANTITIES SHOWN ON THE DRAWINGS OR
SPECIFIED.
25. SUPPORT ALL DUCTWORK FROM STRUCTURE ABOVE TO LIMIT SAG OF Y" PER FOOT BETWEEN
BRACING.
26. COORDINATE ALL CEILING DIFFUSERS IN CEILINGS WITH LIGHTING FIXTURES, SPRINKLER HEADS, ETC.
27. ALL MECHANICAL EQUIPMENT AND CONTROLS SHALL BE LABELED FOR FUNCTION AND IDENTIFICATION.
28. PRIOR TO PURCHASE OF ANY EQUIPMENT, CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF
EACH EQUIPMENT WITH ELECTRICAL CONTRACTOR.
29. CONTROLS AND CONTROL WIRING REQUIRED FOR MECHANICAL SYSTEM SHALL BE FURNISHED AND
INSTALLED BY MECHANICAL CONTRACTOR.
30. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR
AFTER ACCEPTANCE BY THE OWNER.
31. ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 5-YEAR MANUFACTURER'S WARRANTY.
City Of Edmonds
Building Department
Work
INTERIOR MECHANCAL
Address
22315 HIGHWAY 99
--------------------------------------------
Owner
KIDSTRONG
--------------------
Approved Date
04/01 /2024
Building Official
Erg
Permit Number
BLD2024-0190
This permit has been reviewed for interior equipment only.
Exterior packaged RTU's to installed under separate permit.
Testing and balancing shall be done with all equipment
installed, regardless of separate permits. Provide reports to City
Inspector.
ao
M
Q�
0
N
Z
0
o_
o'
co
3:
w
o
o
>
U)
12
0
w
e-
Y
O
U
0
0
N
0
z
d . rosas
D E S I G N
G R O U P
5958 e. corrine dr. ste 102
scottsdale, az 85254
PHONE 480.719.0790
dinar@drosas.com
201 REQISTEREO
ARCHITECT
3-15-24
THOMAS J. ME
SUK
ATE OF WASHINGTON
RESUB
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
N
0 00
Z
paa
F 20
Cl) = Z
Q Lo 0
N 0
cV W
O
LL
z
0
0
z
w
U
w
O
DRAWN: ,J,g.
DATE: 9.12.23
SCALE:
SEE PLAN
JOB NO:
SHEET: MMO
SEAT LOSS CALCLULATIONS
ROOM NAME: FLOOR 1
AREA:
1285 SQ. FT.
CEILING HEIGHT
12 FT.
ROOF
6.4 x 1285
WALL
8.3 x 552
GLASS
41.0 x 120
OUTSIDE AIR
69.1 x 530
TOTAL
ROOM NAME: FLOOR 2
8,225BTU/HR
4,582
4,920
36,625
54, 352 BTU/HR
AREA:
1220 SQ. FT.
CEILING HEIGHT
12 FT.
ROOF
6.4 x 1220
8,708 BTU/HR
WALL
8.3 x 552
4,582
GLASS
41.0 x 48
1,968
OUTSIDE AIR
69.1 x 530
36,625
TOTAL
ROOM NAME: ENTRANCE
51,8832 BTU/HR
AREA:
580 SQ. FT.
CEILING HEIGHT
12 FT.
ROOF
6.4 x 580
3,712 BTU.HR
WALL
8.3 x 228
1,892
GLASS
41.0 x 120
4,920
OUTSIDE AIR
69.1 x 170
11,747
TOTAL
22,271 BTU/HR
SEAT GAINS CALCLULATIONS
ROOM NAME: FLOOR 1
AREA: 1285 SO. FT.
CEILING HEIGHT 12 FT.
y2101691 l42
ROOF
5.3 x 1285
6,810 BTU/HR
WALL
4.6 x 552
2,539
GLASS
58.4 x 120
7,008
LIGHTS
3.41 x 1500
5,115
PEOPLE
580 x 15
8,700
OUTSIDE AIR
14.3 x 530
7,579
TOTAL
37,751 BTU/HR
LATENT
PEOPLE
870 x 15
13,050 BTU/HR
OUTSIDE AIR
14.6 x 530
7,738
TOTAL
20,788 BTU/HR
TOTAL 58,539 BTU/HR
ROOM NAME: FLOOR 2
AREA: 1220 SO. FT
CEILING HEIGHT 12 FT.
SENSIBLE
ROOF
5.3 x 1220
6,466 BTU/HR
WALL
4.6 x 552
2,539
GLASS
58.4 x 48
2,803
LIGHTS
3.41 x 1500
5,115
PEOPLE
580 x 15
8,700
OUTSIDE AIR
14.3 x 530
7,579
TOTAL
LATENT
PEOPLE
OUTSIDE AIR
TOTAL
TOTAL
870 x 15
14.6 x 530
ROOM NAME: ENTRANCE
AREA: 580 SQ. FT
CEILING HEIGHT 12 FT.
SENSIBLE
33,202 BTU/HR
13,050 BTU/HR
7,738
20,788 BTU/HR
53,990 BTU/HR
ROOF
5.3 x 580
3,074 BTU/HR
WALL
4.6 x 228
1,048
GLASS
58.4 x 120
7,008
LIGHTS
3.41 x 1000
3,410
PEOPLE
250 x 12
3,000
OUTSIDE AIR
14.3 x 170
2,431
TOTAL
LATENT
PEOPLE
OUTSIDE AIR
TOTAL
TOTAL
HVAC FLOOR PLAN
SCALE: 1 /4"=1'-0"
200 x 12
14.6 x 170
19,971 BTU/HR
2,400 BTU/HR
2,482
4,882 BTU/HR
24,853 BTU/HR
m
m
M
N
W
N
H
N
%2
�
N
�
Z
O
a
�
api
U
E
U)
E
Lu
c�
Z
N
a
O
p
n
2
E
°'
w
w
0
0
a
p
�U
2
o
a
a
w
N
0
z
d . rosas
D E S I G N
G R 0 U P
5958 e. corrine dr. ste 102
scottsdale, az 85254
PHONE 480.719.0790
dinar@drosas.com
201 REQISTEREO
ARCHITECT
3-15-24
THOMAS J. MESUK
ATE OF WASHINGTON
HE
RESUB
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Q
0 co
Z�M
O Q
W m v♦
F2 0
= Z
QLo 0
r
N 0
N W
O
z
O
O
z
w
U
w
O
of I
DRAWN: J.B.
DATE: 9.12.23
SCALE:
SEE PLAN
JOB NO:
SHEET:
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF d. rosas AND SHALL REMAIN THEIR PROPERTY. THE USE OF THIS DRAWING SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT WAS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED WITHOUT THEIR WRITTEN CONSENT.
pN
Z0')
tj
71
• x
=o
p 1
3] M
Cm
Z X
_
O z
D
=
rn
ao
C
o�
C
D
III
I�
n
_
D
o
x0
m<00
c
��
C/)_ -n
n m
O70
O
N
_
Z 0
o
m o
Dc
CID
O�
m0
c
co�J
cf)z
C
x�
cf)
MU)
O
T
1 '
D :
r-D
Z
pp
D
Z
O�
C7C7
O
z K
�X
mC
T
v
C
�D
M0
C
N
2
-M
W
(n
mU—
7
D
DZ
Z�
p
p Ln
Z
0
O
? x
p
_
Z V
Z
C C
2 N
Cf)
33
zm
C C
O7
-n
O7_
O
OC
Oz
O ;0
O m
c 00
;U;u
N
W C7
p
D
o
m
0
�
3
0
Z X
0 �
?X
Qom
C x
v
Cc
-o
N
o
�N
--I OD
_
M rm
io
to
00C
W0
00�
o
W=
XD
MD
„Cn
=
_n
n
D
OC
0;113
Vic')
0
0�
m -0
z
z v
z
=
o
cw
D
0
PROJECT: RENOVATION FOR
mIM,
I_w
z
KIDSTRONG
P
oo
M
fll
N
w
W
# AK, --,.
m0
22315 HIGWAY 99 m�K co Cl)
z
o
�M�
N
EDMONDS WA. 98026
Thomas I Mesuk ARCHITECT, L.L.C.
197 Valley Boulevard
Wood -Ridge, New Jersey 07075
Telephone (201) 438-0595
Facsimile (201) 438-1560
_ 0 (;I
z
=
m In
Q m
m
o o
3
IN70mo
00 `D
(�
a N
OD
Cow
o
V O
o N
T
V z
REVISIONIDESCRIPTION
DATE:
BY:
Fl
issued for corporate review
12.12.23
JJM
revised per city of Edmods comments
03.15.24
JJM
BRANCH
DUCT
SUPPLY TAP
5YM BO L
REGISTER
AIRFLOW
\-VOLUME
DAMPER
An II 19TAFil F
I X ;
RETURN TAP
5YMBOL
RECTANGULAR OR
SQUARE DUCTWORK
AIRFLOW
CONICAL
CONN.
FLEXIBLE
DUCT
R ANC CH E
HVAC
UNIT
OUTSIDE
AIR CFM
RETURN
AIR CFM
SUPPLY
AIR CFM
EXHAUST
AIR CFM
PRESSURE
RTU-1
530
2000
2000
--
RTU-2
520
2000
2000
--
RTU-3
170
2000
1600
--
DOSA-1
1200
1200
--
+1200
EF-1
-
100
-100
EF-2
-
100
-100
EF-3
-
100
-100
TOTALS
1200
6000
6000
300
+900
NCH
T
1=-I
ROUND ELBOW
5YMBOL
ROUND DUCTWORK
AIRFLOW
SQUARE ELBOW
5YM BO L
�- FLEXI BLE
VOLUME I DUCT
VOLUME DAMPER
DAMPER
STAINLESS STEEL
DRAW BAND
SMOKE DETECTORS IN
RTU'S RETURN SECTION.
FLEXIBLE DUCT CONNECTORS
BELOW ROOF.
SPLASH BLOCK
NEOPRENE PAD UNDER
SPLASH BLOCK U
METAL NOSE TO
PROTECT LINER
(TYPICAL)
i
WEATHERPROOF SERVICE.
LIGHT.
PACKAGED
ROOFTOP UNIT
L
ROOF STRUCTURE
L
New roof curbs shall be
insulated to a minimum of R13
per WSEC 2"X6"
WEATHERPROOF
SERVICE RECEPTACLES
NOTE:
SMOKE DETERCTOR SHALL BE TIED INTO
SUPPLY DUCT WHERE BUILDING FIRE ALARM SYSTEM RTU SHALL
SHOWN ON PLANS SHUT DOWN AND SHALL ACTIVATE A VISIBLE
AND AUDIBLE ALARM LOCATED IN THE OFFICE
CTWORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE. AREA.
DIFFIJI'S . LE &- EGI STER SCHEDULE
SYMBOL
MANUFACTURER
MODEL
TYPE
NECK SIZE
(L"XW")
FACE SIZE
(L"XW")
FRAME SIZE
NC
REMARKS
A
PRICE
SCD
LOUVERED SUPPLY DIFFUSER
PER PLAN
12"X12"
SURFACE
<30
MATCH CEILING COLOR
B
PRICE
SCD
LOUVERED SUPPLY DIFFUSER
PER PLAN
24"X24"
LAY -IN
<30
MATCH CEILING COLOR
C
PRICE
HCD
HIGH CAPACITY DRUM DIFFUSER
PER PLAN
PER PLAN
SURFACE
<30
COLOR PER ARCHITECT
D
PRICE
85
LOUVERED EXHAUST DIFFUSER
PER PLAN
12"X12"
SURFACE
<30
MATCH CEILING COLOR
FAN SCHEDULE
SYMBOL
MANUFACTURER
MODEL
AIRFLOW
(CFM)
EXT. SP
(IN W.C.)
RPM
V.PH,HZ
MOTOR
SIZE (HP)
NOTES
EF-1
CARNES
VCDK 009C
100
.10"
1330
120/1/60
45W
INTERLOCK WITH LIGHT
EF-2
CARNES
VCDK 009C
100
.10"
1330
120/1/60
45W
INTERLOCK WITH LIGHT
EF-3
CARNES
VCDK 009C
100
.10"
1330
120/1/60
45W
INTERLOCK WITH LIGHT
MEl
ND ORDRE FURNISHED AND INSTALLED
EXI STI N G PACKAGE UNIT SCHEDULE BY TTHEOLAUNITS
DX COOLING COIL
HEATING
ELECTRICAL
SYMBOL
MANUFACTURER
MODEL
AIRFLOW
OUTSIDE AIR
AMBIENT
EXT. SIP
APPROXIMATE
WEIGHT
REMARKS
V, PH, HZ
MCA
MOCP
EER
(CFM)
(CFM)
(OAT)
(IN W.C.)
EAT
TOTAL
SENSIBLE
FUEL
ENTERING
LEAVING
MBH
(SEER)
(DB/WB)
(MBH)
(MBH)
AIR TEMP
AIR TEMP
LBS
RTU-1
TRANE
YHC0 (5.0 TON) TON) A
2000
---
95
0.85
94.0/79.2
60.0
45.29
GAS
70.0
99.9
64.0
208/3/60
15
20
13.0
748
RTU-2
TRANE
YHC067E4RMA
(5.0 TON)
2000
---
95
0.85
94.0/79.2
60.0
45.29
GAS
70.0
99.9
64.0
208/3/60
15
20
13.0
748
RTU-3
TRANE
YHC067E4RMA
(5.0 TON)
2000
---
95
0.85
94.0/79.2
60.0
45.29
GAS
70.0
99.9
64.0
208/3/60
15
20
13.0
748
ACCESSORIES: ROOF CURB, DISCONNECT SWITCH, ECONOMIZER, TEMPERATURE SENSOR WITH 7 DAY PROGRAMMABLE THERMOSTATS,
THERMOSTAT/SENSOR MUST BE W1FI ECOBEE3 AND CAN WORK WITH ALL MANUFACTURER'S UNITS.
D FRAME
ROOFING %
I
SELF TAPPING
METAL SCREWS
F1-A5HING AND
COU NTERFLA5111 NG
ROOFING
SPECIFIED
DUCT 51ZE
v
CAULK
DETAIL OF DUCT PENETRATION THRU ROOF
NOT TO SCALE
RUBBER —IN —SHEAR
VIBRATION ISOLATORS
DISCHARGE CAP
JOIST
ST DUCT
CH. CONTR.
Y ROUTING
_ SIZES IN FIELD)
EXHAUST FAN
o
o EXHAUST FAN
BACKDRAFT
T DAMPER
EXHAUST
EXHAUST
1" X 1/16" MIN (DUCTS UNDER 2 SQ.
FT.)
FOR DUCTS OVER 49" WIDE, TURN METAL
STRAP UNDER BOTTOM OF DUCT AND
FASTEN
TnI I CT E-"H AU ST FAN DETAIL
f TO SCALE
DISTANCE BETWEEN DUCT HANGERS SHALL BE IN
ACCORDANCE WITH THE RULES OF THE AGENCIES
HAVING JURISDICTION.
2x2x16 GA. ANGLE
3/8" MACHINE
BOLT 1
3/8" MACHINE
36" DIA. MAX
MAX WEIGHT PER
FOOT = 16 LBS.
INSULATION
3/8" TH
ROD
RECTANGULAR DUCTS
ROUND
DUCTS
LONGITUDINAL SEAM
MIN.
GALV. SHT.
SPIRAL SEAM DUCT STEEL MIN.
DUCT STEEL MIN.
FITTINGS STEEL M
MAX. SIDE INCHES
GAUGE ALUMINUM
MIN. B & S GAUGE
DIAMETER INCHES
GALV.
SHT. GAUGE
GALV. SHT. GAUGE
GALV.
SHT. GAUGI
THROUGH 12
26
(0.022 IN. )
24
(0.020 IN. )
THROUGH 12
28
(0.019 IN. )
26
(0.022 IN. )
26
(0.022 IN. )
13 THROUGH 30
24
(0.028 IN. )
22
(0.025 IN. )
13 THROUGH 18
26
(0.022 IN. )
24
(0.028 IN. )
24
(0.028 IN. )
31 THROUGH 54
22
(0.034 IN. )
20
(0.032 IN. )
19 THROUGH 28
24
(0.028 IN. )
22
(0.034 IN. )
22
(0.034 IN. )
55 THROUGH 84
20
(0.040 IN. )
18
(0.040 IN. )
29 THROUGH 36
22
(0.034 IN. )
20
(0.040 IN. )
20
(0.040 IN. )
OVER 84
18
(0.052 IN.
16
(0.051 IN. )
37 THROUGH 52
20
(0.040 IN.)
18
(0.052 IN.
18
(0.052 IN. ;
TIMMIN-1-mm
NOT "'W SCALE
DOHS
SCHEDULE
ELECTRIC
DIMENSIONS
UNIT
MODEL
AREA SERVED
BLOWER
OUTSIDE AIR
WEIGHT
NOTES
ID
CFM
CFM
VOLTS
PHASE
FLA
MOP
L X W X H
LBS
DOAS-1
E1800L-FII-N
STUDIOS 1,2&3
1200
1200
120
1
14.7
20A
45"X48"X30"
230
NOTES:
1. UNIT SELECTIONS BASED ON CARRIER CORP.
2. PROVIDE MOUNTING BRACKETS AND ACCESSORIES
IF HUNG.
3. CLEARANCES TO MEET FIELD CONDITIONS.
lit
:�it
m
�Lj
N
N
Q
z
O
aN
o'
U
E
W
0
EO
Z
U
N
o
L
0
>
>
a)
w
w
Ofo
a
_a
O
U
U
O
O_
a
>
0
z
d . rosas
D E S I G N
G R O U P
5958 e. corrine dr. ste 102
Scottsdale, az 85254
PHONE 480.719.0790
dinar@drosas.com
REGISTERED
ARCHITECT
3-15-24
THOMAS J. MESUK
TATE OF WASHINGTON
RESUB
Mar 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
to
N
� 0000
Z
O Q Q
V
= Z
QLn
r
N �
cV W
o'
o
z
O
O
z
Lu
U
w
0
@
DRAWN: J.B.
DATE: 9.12.23
SCALE:
SEE PLAN
JOB NO:
SHEET:
Mm3