Loading...
APPROVED BLD RESUB1 BLD2024-0190+Mechanical_Plan+3.18.2024_2.54.21_PM+4142118MECHANICAL ABBREVIATIONS MECHANICAL LEGEND CD CEILING DIFFUSER SA SUPPLY AIR FLEXIBLE DUCT RA RETURN AIR WB WET BULB OA OUTSIDE AIR RETURN/EXHAUST DUCT VERTICAL LAT LEAVING AIR TEMPERATURE EAT EXTERNAL AIR TEMPERATURE E.S.P. EXTERNAL STATIC PRESSURE (IN W.C.) ® SUPPLY DUCT VERTICAL WC WATER COLUMN EA EXHAUST AIR 8"0 ROUND DUCT AFF ABOVE FINISHED FLOOR DB DRY BULB FLR FLOOR 1OX8 NEW DUCT (WIDTH X DEPTH) RL REFRIGERANT LIQUID IRS REFRIGERANT SUCTION HP HORSEPOWER FLEXIBLE CONNECTION CFM CUBIC FEET PER MINUTE FC MBH THOUSAND BTU PER HOUR BTU BRITISH THERMAL UNIT EF EXHAUST FAN MANUAL VOLUME DAMPER FC FAN COIL VD CU CONDENSING UNIT SEER SEASONAL ENERGY EFFICIENCY RATING PVC POLYVINYL CHLORIDE CONDUIT SPIN IN W/ DAMPER & SCOOP SUPPLY 14X10 10X10 TRANSITION FIRE DAMPER FD CEILING RADIATION DAMPER CRD SIDEWALL SUPPLY DIFFUSER SIDEWALL RETURN AIR GRILLE ® SUPPLY DIFFUSER CEILING MOUNTED zRETURN DIFFUSER/REGISTER OT S THERMOSTAT O THERMOSTATIC SENSOR EF EQUIPMENT TAG (TYPE IS ON TOP AND 1 NUMBER IDENTIFIER ON BOTTOM) A DIFFUSER TAG (TYPE IS ON TOP AND CFM 50 IS ON BOTTOM) SD SMOKE DETECTOR ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE MECHANICAL NOTES AND SPECIFICATIONS 1. THE CONTRACTOR SHALL PROVIDE A COMPLETE HVAC SYSTEM WHICH INCLUDES ALL LABOR, MATERIALS TOOLS, AND EQUIPMENT FOR A COMPLETE AND FUNCTIONAL SYSTEM AND ALL NECESSARY APPURTENANCES CUSTOMARILY INCLUDED IF NOT SPECIFICALLY CALLED OUT. 2. DEVIATION FROM MATERIALS, METHODS AND PROCEDURES SET FORTH HEREIN MUST BE APPROVED IN WRITING. APPROVAL WILL NOT BE GIVEN UNLESS THE PROPOSED SYSTEM IS EQUAL IN PERFORMANCE, DURABILITY LONGEVITY, AND RELIABILITY TO THAT SPECIFIED. 3. ALL INSTALLATIONS SHALL CONFORM TO THE WASHINGTON STATE BUILDING CODE WITH THE LATEST AMENDMENTS, THE WASHINGTON STATE MECHANICAL CODE WITH THE LATEST AMENDMENTS, THE WASHINGTON STATE FUEL GAS CODE WITH THE LATEST AMENDMENTS, THE WASHINGTON STATE ENERGY CONSERVATION CODE WITH AMENDMENTS AND NFPA 90A. FOR ALL MECHANICAL CODES AND INFORMATION REFER TO ARCHITECTURAL DRAWINGS A-1. 4. SUBMISSION OF A BID OR PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS BECOME FAMILIARIZED WITH THE PLANS, SPECIFICATIONS, AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO BIDS FOR MATERIALS AND/OR LABOR DUE TO DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED, UNLESS DIFFICULTIES COULD NOT HAVE BEEN FORESEEN EVEN THOUGH PROPER EXAMINATION HAD BEEN MADE. 5. SHOULD ANY EQUIPMENT FURNISHED BY THE CONTRACTOR DIFFER FROM BASE ITEMS INDICATED OR SPECIFIED HEREIN, WHICH MAY REQUIRE ADDED COST TO THE OTHER TRADES, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO ASSUME THE COST INVOLVED. 6. UNLESS "APPROVED EQUAL" IS SPECIFICALLY STATED, BIDS SHALL BE BASED ON THE EQUIPMENT NAMED ON DRAWINGS AS "BASE" OR "EQUAL" PRODUCTS. RTU'S, EXHAUST FANS ARE LIMITED TO CORPORATE APPROVAL 7. "EQUAL PRODUCT" AND "APPROVED EQUAL" ITEMS LISTED SHALL CONFORM TO SPECIFIED BASE ITEMS AND SHALL BE SUBSTANTIALLY EQUAL IN WEIGHT, CONSTRUCTION, AND CAPACITIES. RTU'S, EXHAUST FANS ARE LIMITED TO CORPORATE APPROVAL. 8. THE CONTRACTOR SHALL REVIEW STRUCTURAL DRAWINGS BEFORE FABRICATING OR INSTALLING DUCTWORK OR EQUIPMENT TO AVOID ANY CONFLICTS. 9. ALL DUCT SHALL BE AIRTIGHT, FREE OF LEAKS, MEET ENERGY CODE COMPLIANCE AND SHALL BE INSPECTED FOR LEAKS PRIOR TO INSTALLATION OF FINISHED CEILING SYSTEM. 10. DUCTWORK, DAMPERS, LOWERS, AND OTHER DISTRIBUTION EQUIPMENT AND MATERIALS SHALL CONFORM TO THE FOLLOWING: A. ASHRAE/ANSI E. AMCA STANDARD HANDBOOK 99 B. SBCCl/ASME F. AIR DIFFUSION COUNCIL TEST CODE 1062R3 C. SMACNA G. ANY LOCAL CODES NOT COVERED ABOVE D. NFPA 11. ALL DUCT SIZES ARE CLEAR NET INSIDE DIMENSIONS. WHERE INTERNAL INSULATION IS CALLED FOR, DIMENSIONS SHALL BE INCREASED BY THE THICKNESS OF THE INSULATION. 12. FLEXIBLE DUCTWORK SHALL BE CLASS 1, UL 181 WITH A MINIMUM R VALUE OF R-6, SAME SIZE AS DIFFUSER NECKS. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE, AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 48". 13. SHEET METAL SUPPLY, RETURN, & OA DUCTWORK IN NON -AIR CONDITIONED AREAS AND MECHANICAL ROOMS SHALL BE INSULATED WITH 2" THICK FIBERGLASS DUCT INSULATION WITH FOIL VAPOR BARRIER, U.L. ISTED, MINIMUM R-6. 14. ALL LOW PRESSURE ROUND DUCT SHALL BE CONNECTED TO LOW PRESSURE DUCT WITH SPIN -IN FITTINGS WITH 45' EXTRACTOR AND ADJUSTABLE MANUAL DAMPERS. NOTE: HVAC CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL OF THE FOLLOWING ITEMS: - NEW ROOFTOP UNITS - SUPPLY AND RETURN DUCTWORK - REGISTERS AND DIFFUSERS - EXHAUST FANS ANY EQUIPMENT INSTALLED WITHOUT APPROVAL WILL BECOME THE CONTRACTORS RESPONSIBILITY IF REJECTED BY THE BUIDLING DEPARTMENT FINAL INSPECTION, AND OR REVIEWED BY THIS OFFICE. AT THE COMPLETION OF THE HVAC SYSTEM THE MECHANICAL CONTRACTOR SHALL FURNISH A AIR BALANCE REPORT SIGNED AND SEALED BY A PROFESSIONAL ENGINEER. 15. PROGRAMMABLE THERMOSTATS SHALL BE INSTALLED AT 4'-0" AFF 16. THE ENGINEER RESERVES THE RIGHT TO DIRECT THE REMOVAL OF ANY ITEM WHICH, IN HIS OPINION, DOES NOT PRESENT AN ORDERLY AND REASONABLY NEAT OR WORKMANLIKE APPEARANCE. SUCH REMOVAL AND REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE ENGINEER, AT THE CONTRACTOR'S EXPENSE, AND WITHOUT ADDITIONAL COST TO THE OWNER. 17. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 18. ALL REFRIGERANT PIPING SHALL BE COPPER TUBING, TYPE L, HARD DRAWN, ASTM B88-1988a, LONG RADIUS FITTINGS AND BRAZED JOINTS. JOINTS SHALL NOT BE LOCATED WITHIN WALLS OR OTHER CONCEALED SPACES. 19. ALL REFRIGERANT PIPING TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS. ALL SUCTION LINES SHALL BE INSULATED WITH SEAMLESS CLOSED CELL ELASTOMERIC INSULATION, 3/4" THINK MINIMUM. 20. THE ENTIRE REFRIGERANT PIPING SYSTEM SHALL COMPLY WITH ANSI/ASHRAE STANDARD 15. 21. ALL INSULATING MATERIALS SHALL HAVE A COMPOSITE FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50 (ASTM E-84, NFPA 255 & UL 723). 22. PROVIDE FLEXIBLE CONNECTION WHERE DUCT CONNECTS TO AIR CONDITIONER OR FURNACE. 23. ALL PIPE PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL BE FULLY SEALED AND FIRE CAULKED WITH UL LISTED SEALANT. ALL PIPE PENETRATIONS SHALL CONFORM WITH APPROPRIATE FIRE RATED ASSEMBLY METHOD AS PER 2005 U.L. FIRE RESISTANCE DIRECTORY AND LOCAL AHJ. 24. BALANCE ALL AIR SYSTEMS TO ACHIEVE THE VOLUME AND QUANTITIES SHOWN ON THE DRAWINGS OR SPECIFIED. 25. SUPPORT ALL DUCTWORK FROM STRUCTURE ABOVE TO LIMIT SAG OF Y" PER FOOT BETWEEN BRACING. 26. COORDINATE ALL CEILING DIFFUSERS IN CEILINGS WITH LIGHTING FIXTURES, SPRINKLER HEADS, ETC. 27. ALL MECHANICAL EQUIPMENT AND CONTROLS SHALL BE LABELED FOR FUNCTION AND IDENTIFICATION. 28. PRIOR TO PURCHASE OF ANY EQUIPMENT, CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH EQUIPMENT WITH ELECTRICAL CONTRACTOR. 29. CONTROLS AND CONTROL WIRING REQUIRED FOR MECHANICAL SYSTEM SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. 30. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY THE OWNER. 31. ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 5-YEAR MANUFACTURER'S WARRANTY. City Of Edmonds Building Department Work INTERIOR MECHANCAL Address 22315 HIGHWAY 99 -------------------------------------------- Owner KIDSTRONG -------------------- Approved Date 04/01 /2024 Building Official Erg Permit Number BLD2024-0190 This permit has been reviewed for interior equipment only. Exterior packaged RTU's to installed under separate permit. Testing and balancing shall be done with all equipment installed, regardless of separate permits. Provide reports to City Inspector. ao M Q� 0 N Z 0 o_ o' co 3: w o o > U) 12 0 w e- Y O U 0 0 N 0 z d . rosas D E S I G N G R O U P 5958 e. corrine dr. ste 102 scottsdale, az 85254 PHONE 480.719.0790 dinar@drosas.com 201 REQISTEREO ARCHITECT 3-15-24 THOMAS J. ME SUK ATE OF WASHINGTON RESUB Mar 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W N 0 00 Z paa F 20 Cl) = Z Q Lo 0 N 0 cV W O LL z 0 0 z w U w O DRAWN: ,J,g. DATE: 9.12.23 SCALE: SEE PLAN JOB NO: SHEET: MMO SEAT LOSS CALCLULATIONS ROOM NAME: FLOOR 1 AREA: 1285 SQ. FT. CEILING HEIGHT 12 FT. ROOF 6.4 x 1285 WALL 8.3 x 552 GLASS 41.0 x 120 OUTSIDE AIR 69.1 x 530 TOTAL ROOM NAME: FLOOR 2 8,225BTU/HR 4,582 4,920 36,625 54, 352 BTU/HR AREA: 1220 SQ. FT. CEILING HEIGHT 12 FT. ROOF 6.4 x 1220 8,708 BTU/HR WALL 8.3 x 552 4,582 GLASS 41.0 x 48 1,968 OUTSIDE AIR 69.1 x 530 36,625 TOTAL ROOM NAME: ENTRANCE 51,8832 BTU/HR AREA: 580 SQ. FT. CEILING HEIGHT 12 FT. ROOF 6.4 x 580 3,712 BTU.HR WALL 8.3 x 228 1,892 GLASS 41.0 x 120 4,920 OUTSIDE AIR 69.1 x 170 11,747 TOTAL 22,271 BTU/HR SEAT GAINS CALCLULATIONS ROOM NAME: FLOOR 1 AREA: 1285 SO. FT. CEILING HEIGHT 12 FT. y2101691 l42 ROOF 5.3 x 1285 6,810 BTU/HR WALL 4.6 x 552 2,539 GLASS 58.4 x 120 7,008 LIGHTS 3.41 x 1500 5,115 PEOPLE 580 x 15 8,700 OUTSIDE AIR 14.3 x 530 7,579 TOTAL 37,751 BTU/HR LATENT PEOPLE 870 x 15 13,050 BTU/HR OUTSIDE AIR 14.6 x 530 7,738 TOTAL 20,788 BTU/HR TOTAL 58,539 BTU/HR ROOM NAME: FLOOR 2 AREA: 1220 SO. FT CEILING HEIGHT 12 FT. SENSIBLE ROOF 5.3 x 1220 6,466 BTU/HR WALL 4.6 x 552 2,539 GLASS 58.4 x 48 2,803 LIGHTS 3.41 x 1500 5,115 PEOPLE 580 x 15 8,700 OUTSIDE AIR 14.3 x 530 7,579 TOTAL LATENT PEOPLE OUTSIDE AIR TOTAL TOTAL 870 x 15 14.6 x 530 ROOM NAME: ENTRANCE AREA: 580 SQ. FT CEILING HEIGHT 12 FT. SENSIBLE 33,202 BTU/HR 13,050 BTU/HR 7,738 20,788 BTU/HR 53,990 BTU/HR ROOF 5.3 x 580 3,074 BTU/HR WALL 4.6 x 228 1,048 GLASS 58.4 x 120 7,008 LIGHTS 3.41 x 1000 3,410 PEOPLE 250 x 12 3,000 OUTSIDE AIR 14.3 x 170 2,431 TOTAL LATENT PEOPLE OUTSIDE AIR TOTAL TOTAL HVAC FLOOR PLAN SCALE: 1 /4"=1'-0" 200 x 12 14.6 x 170 19,971 BTU/HR 2,400 BTU/HR 2,482 4,882 BTU/HR 24,853 BTU/HR m m M N W N H N %2 � N � Z O a � api U E U) E Lu c� Z N a O p n 2 E °' w w 0 0 a p �U 2 o a a w N 0 z d . rosas D E S I G N G R 0 U P 5958 e. corrine dr. ste 102 scottsdale, az 85254 PHONE 480.719.0790 dinar@drosas.com 201 REQISTEREO ARCHITECT 3-15-24 THOMAS J. MESUK ATE OF WASHINGTON HE RESUB Mar 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Q 0 co Z�M O Q W m v♦ F2 0 = Z QLo 0 r N 0 N W O z O O z w U w O of I DRAWN: J.B. DATE: 9.12.23 SCALE: SEE PLAN JOB NO: SHEET: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF d. rosas AND SHALL REMAIN THEIR PROPERTY. THE USE OF THIS DRAWING SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT WAS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD IN WHOLE OR IN PART IS PROHIBITED WITHOUT THEIR WRITTEN CONSENT. pN Z0') tj 71 • x =o p 1 3] M Cm Z X _ O z D = rn ao C o� C D III I� n _ D o x0 m<00 c �� C/)_ -n n m O70 O N _ Z 0 o m o Dc CID O� m0 c co�J cf)z C x� cf) MU) O T 1 ' D : r-D Z pp D Z O� C7C7 O z K �X mC T v C �D M0 C N 2 -M W (n mU— 7 D DZ Z� p p Ln Z 0 O ? x p _ Z V Z C C 2 N Cf) 33 zm C C O7 -n O7_ O OC Oz O ;0 O m c 00 ;U;u N W C7 p D o m 0 � 3 0 Z X 0 � ?X Qom C x v Cc -o N o �N --I OD _ M rm io to 00C W0 00� o W= XD MD „Cn = _n n D OC 0;113 Vic') 0 0� m -0 z z v z = o cw D 0 PROJECT: RENOVATION FOR mIM, I_w z KIDSTRONG P oo M fll N w W # AK, --,. m0 22315 HIGWAY 99 m�K co Cl) z o �M� N EDMONDS WA. 98026 Thomas I Mesuk ARCHITECT, L.L.C. 197 Valley Boulevard Wood -Ridge, New Jersey 07075 Telephone (201) 438-0595 Facsimile (201) 438-1560 _ 0 (;I z = m In Q m m o o 3 IN70mo 00 `D (� a N OD Cow o V O o N T V z REVISIONIDESCRIPTION DATE: BY: Fl issued for corporate review 12.12.23 JJM revised per city of Edmods comments 03.15.24 JJM BRANCH DUCT SUPPLY TAP 5YM BO L REGISTER AIRFLOW \-VOLUME DAMPER An II 19TAFil F I X ; RETURN TAP 5YMBOL RECTANGULAR OR SQUARE DUCTWORK AIRFLOW CONICAL CONN. FLEXIBLE DUCT R ANC CH E HVAC UNIT OUTSIDE AIR CFM RETURN AIR CFM SUPPLY AIR CFM EXHAUST AIR CFM PRESSURE RTU-1 530 2000 2000 -- RTU-2 520 2000 2000 -- RTU-3 170 2000 1600 -- DOSA-1 1200 1200 -- +1200 EF-1 - 100 -100 EF-2 - 100 -100 EF-3 - 100 -100 TOTALS 1200 6000 6000 300 +900 NCH T 1=-I ROUND ELBOW 5YMBOL ROUND DUCTWORK AIRFLOW SQUARE ELBOW 5YM BO L �- FLEXI BLE VOLUME I DUCT VOLUME DAMPER DAMPER STAINLESS STEEL DRAW BAND SMOKE DETECTORS IN RTU'S RETURN SECTION. FLEXIBLE DUCT CONNECTORS BELOW ROOF. SPLASH BLOCK NEOPRENE PAD UNDER SPLASH BLOCK U METAL NOSE TO PROTECT LINER (TYPICAL) i WEATHERPROOF SERVICE. LIGHT. PACKAGED ROOFTOP UNIT L ROOF STRUCTURE L New roof curbs shall be insulated to a minimum of R13 per WSEC 2"X6" WEATHERPROOF SERVICE RECEPTACLES NOTE: SMOKE DETERCTOR SHALL BE TIED INTO SUPPLY DUCT WHERE BUILDING FIRE ALARM SYSTEM RTU SHALL SHOWN ON PLANS SHUT DOWN AND SHALL ACTIVATE A VISIBLE AND AUDIBLE ALARM LOCATED IN THE OFFICE CTWORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE. AREA. DIFFIJI'S . LE &- EGI STER SCHEDULE SYMBOL MANUFACTURER MODEL TYPE NECK SIZE (L"XW") FACE SIZE (L"XW") FRAME SIZE NC REMARKS A PRICE SCD LOUVERED SUPPLY DIFFUSER PER PLAN 12"X12" SURFACE <30 MATCH CEILING COLOR B PRICE SCD LOUVERED SUPPLY DIFFUSER PER PLAN 24"X24" LAY -IN <30 MATCH CEILING COLOR C PRICE HCD HIGH CAPACITY DRUM DIFFUSER PER PLAN PER PLAN SURFACE <30 COLOR PER ARCHITECT D PRICE 85 LOUVERED EXHAUST DIFFUSER PER PLAN 12"X12" SURFACE <30 MATCH CEILING COLOR FAN SCHEDULE SYMBOL MANUFACTURER MODEL AIRFLOW (CFM) EXT. SP (IN W.C.) RPM V.PH,HZ MOTOR SIZE (HP) NOTES EF-1 CARNES VCDK 009C 100 .10" 1330 120/1/60 45W INTERLOCK WITH LIGHT EF-2 CARNES VCDK 009C 100 .10" 1330 120/1/60 45W INTERLOCK WITH LIGHT EF-3 CARNES VCDK 009C 100 .10" 1330 120/1/60 45W INTERLOCK WITH LIGHT MEl ND ORDRE FURNISHED AND INSTALLED EXI STI N G PACKAGE UNIT SCHEDULE BY TTHEOLAUNITS DX COOLING COIL HEATING ELECTRICAL SYMBOL MANUFACTURER MODEL AIRFLOW OUTSIDE AIR AMBIENT EXT. SIP APPROXIMATE WEIGHT REMARKS V, PH, HZ MCA MOCP EER (CFM) (CFM) (OAT) (IN W.C.) EAT TOTAL SENSIBLE FUEL ENTERING LEAVING MBH (SEER) (DB/WB) (MBH) (MBH) AIR TEMP AIR TEMP LBS RTU-1 TRANE YHC0 (5.0 TON) TON) A 2000 --- 95 0.85 94.0/79.2 60.0 45.29 GAS 70.0 99.9 64.0 208/3/60 15 20 13.0 748 RTU-2 TRANE YHC067E4RMA (5.0 TON) 2000 --- 95 0.85 94.0/79.2 60.0 45.29 GAS 70.0 99.9 64.0 208/3/60 15 20 13.0 748 RTU-3 TRANE YHC067E4RMA (5.0 TON) 2000 --- 95 0.85 94.0/79.2 60.0 45.29 GAS 70.0 99.9 64.0 208/3/60 15 20 13.0 748 ACCESSORIES: ROOF CURB, DISCONNECT SWITCH, ECONOMIZER, TEMPERATURE SENSOR WITH 7 DAY PROGRAMMABLE THERMOSTATS, THERMOSTAT/SENSOR MUST BE W1FI ECOBEE3 AND CAN WORK WITH ALL MANUFACTURER'S UNITS. D FRAME ROOFING % I SELF TAPPING METAL SCREWS F1-A5HING AND COU NTERFLA5111 NG ROOFING SPECIFIED DUCT 51ZE v CAULK DETAIL OF DUCT PENETRATION THRU ROOF NOT TO SCALE RUBBER —IN —SHEAR VIBRATION ISOLATORS DISCHARGE CAP JOIST ST DUCT CH. CONTR. Y ROUTING _ SIZES IN FIELD) EXHAUST FAN o o EXHAUST FAN BACKDRAFT T DAMPER EXHAUST EXHAUST 1" X 1/16" MIN (DUCTS UNDER 2 SQ. FT.) FOR DUCTS OVER 49" WIDE, TURN METAL STRAP UNDER BOTTOM OF DUCT AND FASTEN TnI I CT E-"H AU ST FAN DETAIL f TO SCALE DISTANCE BETWEEN DUCT HANGERS SHALL BE IN ACCORDANCE WITH THE RULES OF THE AGENCIES HAVING JURISDICTION. 2x2x16 GA. ANGLE 3/8" MACHINE BOLT 1 3/8" MACHINE 36" DIA. MAX MAX WEIGHT PER FOOT = 16 LBS. INSULATION 3/8" TH ROD RECTANGULAR DUCTS ROUND DUCTS LONGITUDINAL SEAM MIN. GALV. SHT. SPIRAL SEAM DUCT STEEL MIN. DUCT STEEL MIN. FITTINGS STEEL M MAX. SIDE INCHES GAUGE ALUMINUM MIN. B & S GAUGE DIAMETER INCHES GALV. SHT. GAUGE GALV. SHT. GAUGE GALV. SHT. GAUGI THROUGH 12 26 (0.022 IN. ) 24 (0.020 IN. ) THROUGH 12 28 (0.019 IN. ) 26 (0.022 IN. ) 26 (0.022 IN. ) 13 THROUGH 30 24 (0.028 IN. ) 22 (0.025 IN. ) 13 THROUGH 18 26 (0.022 IN. ) 24 (0.028 IN. ) 24 (0.028 IN. ) 31 THROUGH 54 22 (0.034 IN. ) 20 (0.032 IN. ) 19 THROUGH 28 24 (0.028 IN. ) 22 (0.034 IN. ) 22 (0.034 IN. ) 55 THROUGH 84 20 (0.040 IN. ) 18 (0.040 IN. ) 29 THROUGH 36 22 (0.034 IN. ) 20 (0.040 IN. ) 20 (0.040 IN. ) OVER 84 18 (0.052 IN. 16 (0.051 IN. ) 37 THROUGH 52 20 (0.040 IN.) 18 (0.052 IN. 18 (0.052 IN. ; TIMMIN-1-mm NOT "'W SCALE DOHS SCHEDULE ELECTRIC DIMENSIONS UNIT MODEL AREA SERVED BLOWER OUTSIDE AIR WEIGHT NOTES ID CFM CFM VOLTS PHASE FLA MOP L X W X H LBS DOAS-1 E1800L-FII-N STUDIOS 1,2&3 1200 1200 120 1 14.7 20A 45"X48"X30" 230 NOTES: 1. UNIT SELECTIONS BASED ON CARRIER CORP. 2. PROVIDE MOUNTING BRACKETS AND ACCESSORIES IF HUNG. 3. CLEARANCES TO MEET FIELD CONDITIONS. lit :�it m �Lj N N Q z O aN o' U E W 0 EO Z U N o L 0 > > a) w w Ofo a _a O U U O O_ a > 0 z d . rosas D E S I G N G R O U P 5958 e. corrine dr. ste 102 Scottsdale, az 85254 PHONE 480.719.0790 dinar@drosas.com REGISTERED ARCHITECT 3-15-24 THOMAS J. MESUK TATE OF WASHINGTON RESUB Mar 18 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT to N � 0000 Z O Q Q V = Z QLn r N � cV W o' o z O O z Lu U w 0 @ DRAWN: J.B. DATE: 9.12.23 SCALE: SEE PLAN JOB NO: SHEET: Mm3