Loading...
APPROVED ENG2024-0238 ROW PERMITOF WAY PERMIT PERMIT ER City •EdmondsRIGHT 98020 ENG2024-023]8 www.edmondswa.gov i Description: ROW - FIRE SPRINKLER SERVICE REPAIR DUE TO TRAFFIC ACCIDENT ISSUED: 06/21/2024 Address: 307 BELL ST EDMONDS WA 98020 EXPIRES: 06/16/2025 Permit Type: RIGHT OF WAY Permit Subtype: MIXED USE Parcel Number: 00434400501100 Isle] NAME TYPE NAME ADDRESS PHONE APPLICANT DOUGLAS SPEE 307 BELL ST. SUITE 101, EDMONDS WA 98020 (206)284-7733 CONTACT SPEE WEST CONSTRUCTION 307 BELL ST. SUITE 101, EDMONDS WA 98020 (206)284-7733 CONTRACTOR SPEE WEST CONSTRUCTION CO 307 BELL STREET 101, EDMONDS WA 98020 (206)284-7733 OWNER EDMONDS 2000 LLC 307 BELL ST STE 101, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS - 4.1.24 $660.00 $660.00 ROW - STANDARD - 4.1.24 $396.00 $396.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: WHJ DATE: 06/21/2024 Printed: Friday, June 21, 2024 12:29:39 PM 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBE3 City of Edmonds www.edmondswa.gov • • CONDITIONS CONDITION TYPE It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. INSP PRIOR TO BACKFILL Call for all required inspections. All work shall be inspected prior to backfill. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROLS Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE am X-2 ENGINEERING FINAL" A-1 TESC AND MOBILIZE E-7 CONCRETE SIDEWALK E-7 RESTOR LIMITS E-7 STREET SIGNS E-4 RPBA AND HOTBOX E-7 TRAFFIC CTRL Printed: Friday, June 21, 2024 12:29:39 PM 2 of 2 RECEIVED �y of EDA,iU 13aJ SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right-of-WU permit Handout Eby. MAY 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. General• Project Name S fA Site Address or if no site addreA use Property Address at NW corner of project area: j (/^ Associated Permits: BLD PLN I ENG Owner and Entitv Holdingapplicable) Name of Company _ u n j 2-U u io L-4--c Franchise Ordinance No: Point of Contact O oe Titled Address '3(,--76e 8J City State (^J Zip " 2-d Phone Email % WA Contractor and Authorized Agent of Owner Name of Company , (see note below) A Contractor PrimaryName Agent Name fv 5 le Title Title iK f Mobile ?� Address 1-36� V11 fr 6 Email Ct5F S. t"&AO • eD;­ City State Zip Gr0Z 47 Secondary Nan{e Phone �b ZpJ , -7 3 Title Email d 5 eQ ,Q ' a ii-eS 0 Mobile Email City of Edmonds B iness License o: '� State License No: _r � 90 f� Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NUI t: he U(; 1d.6o.020 requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. Type of •pmapply ❑ Multifamily residential Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as weI� ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page i of 3 Updated 3/25/2021 ❑ Utility Franchise Work (no associated development) Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for iindprurrnind militia,, atr ) RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF Alley 72 hours + LF x LF SF Parking 72 hours + LF x LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. Type of 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. I Does the utility owner have existing overhead infrastructure in the area of work? Yes No 2. 1 Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system.? 5. Does the work involve proposed additions to an aboveground utility system? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of Work to be Completed Yes No 6. 1 Does your project involve rebuilding or replacing utility equipment which currently serves more -F-1 - than one lot or commercial development? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is ro osed: 6a. Does your project involve wires/cables/lines? If yes: How many are existing? I I How many are to be added? 6b. Does your project involve poles? If yes: How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additional oles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: J� How many? What is the height of the poles after? Describe the modification/rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the info erein is correct and complete; and I am authorized by owner to act on its behalf and have autho 'tv bind t own r to this application. Fees. The Applicant is responsible foq aJ' VTi fees. / APPLICANT SIGNATURE: APPLICANT PRINTED NAME: 16/ APPLICANT TITLE: NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE Z� City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM RESUB J U N 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT CJ INSTALL SLEEVE FOR "NO PARKING ANYTIME" SIGN CONTACT KRIS KUHNHAUSEN WITH THE CITY WATER DEPT. AT 425-771-0235 24HRS PRIOR TO WATER SHUT DOWN. LL O w z tr w I-- z w U z O m RESTORATION LIMITS TO BE DETERMINED BY CITY ENGINEERING INSPECTOR I T N 0 N c 00 T a 0 L u COMMERCIAL ONE -I ! 4?E6 E:fIT PA6SAGE'•V:,Y a ------ FULL PANAL SIDEWALK REPAIR SHALL BE REQUIRED NEW 4"X 2-1 /2"X 2-1 /2" AUTO SPRINKLER CONNECTION SET AT36"ABOVE FINISHED GRADE OF SIDEWALK. 4\CL52 DI. Ut4DG m I COI FDC RISE TO BE 4" GALV. SCH.40 PIPE WRAPPED WITH 3 MIL. POLY WRAP BELOW j GRADE. J r 4l' D1.-� 4" DI.. 4" D 1. P.I.V. VALVE SETAT APPROX.40" ABOVE �, 1 EXTERIOR GRADE. VALVE TO BE TAMPERED AND WIRED Y OTHERS. INSPECTION REQUIRED PRIOR TO BACK FILL OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. RISER ROOM LOCATIC DETECTOR CHECK LO ROOM. VALVES TO BE WIRING TO BE DONE E CONTRACTOR. TYRSE PROPERTY LINE CANOPY ABOVE TYP. =P I I BELL STREET SITE PLAN ,SCALE: 1/8"= V-0" Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. 60' R.O.W. ENGINEERING DIVISION APPROVED AS NOTED Jill 1,V - X, $, 44z 06/21 /2024 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROLAND DRAINAGE FOR RESIDENTIALAND COMMERCIAL ;FLOORS. 2" MAIN DRAIN VALVE vvIKCV IvlYl mino OTHERS.TYPICAL. 4' SUPPLY FUK UKT GARAGE SYSTEM AND SMALL COMMERCIAL SPACE. 2 2 4" FLOW SWITCH WITH 9 TAMPER SWITCH TO BE + WIRED BY OTHER. 11 1 300 LB. WATER GAUGE 4' CHECK VALVE FOR AUTO 4 SPRINKLER CONNECTION TO BE 5 PIPED OUT IN THE YARD, SEE SITE 6 COPY FOR LOCATION. 4' FDC CONNECTIV7_ 4' SCH. 53 DUCTILE IRON \� UNDERGROUND RAN FROMNEWWET TAP OUT IN THESTREET. TAP BY OTHERS. 4' DOUBLE DETECTOR CHECK VALVE WITH 2 TAMPER SWITCHES_ SWITCH WIRED TO 16 ALARM BY OTHERS. BOTH DRYAND WET DRAINS TO GANG TOGETHER 9 300 LB AND DUMP INTO STORM DETENTION ROOM. BOTH WATER DRAINS TO HAVE SITE GLASS FOR FLOW TEST. GAUGE 12 - HEAD, HEAD BOX, Ifl WITH HEAD WRENCH. a>a w 4' GROOVED END 10 6 12 BUTTERFLY VALVE WITH TAMPER. 1 f TAMPER WIRED TO ALARM BY OTHERS. 2 TT 1/2- COPPERAIR LINE PIPED 3 TO DRY VALVE. AIR LINE HAS Q - PS-40 LOW PRES.SWITCH WIRED BY OTHERS. 2 / RISEROETAIL SCALE: NONE RISER ASSEMBLY LIST NO. ITEM 1 4' BUTTERFLY VALVE WITH TAMPER 2 4" GRV 90 ELBOW 3 POTTER OSYSU-2 TAMPER SWITCH - 4 POTTER MODEL VSR-F FLOW SWITCH W f RETARD 5 4-DRY PIPE VALVE WITH TRIM 6 300# WATER GAUGE WITH lox 1/4" BUSHING 7 STYLE 743 VIC FLANGE 8 2" GALV.45 PIPED TO STORM DETENTION ROOM 9 4' STYLE 75 FLEXIBLE GRV COUPLING 10 12 SPARE HEAD BOX W/ WRENCH 11 FOUR WAY EARTHQUAKE BRACING AT TOP OF RISER 2" MAIN DRAIN _12- 13 14 4" DOUBLE DETECTOR CHECK VALVE 4' CONT. TO FDC CONN. LOC. OUT IN THE YARD. 15 4" CHECK VALVE ON LINE TO FOC CONN. 16 2" FLOOR STAND 4" GALV. SCHAO 4" CLASS 52 DUCTILE IRON PIPE. TYP. FOR BOTH FDC j f71NtJFr.TICSN tmn _ ` I - GEN.OL6751ACAIR COMP. WIRED BY OTHERS. SYSTEM CAPACITY- 511.94 COMPRESSOR CAPACITY=675 LEGAL DESCRIPTION 307 BELL ST: LOT 12 BLOCK 5 PLAT OF EDMONDS ACCORDING TO PLAT HEREOF RECORDED IN VOLUME I OF PLATS, PAGE 26, RECORDS OF SNOHOMISH COUNTY, WA- 210 3RD. AVE. N:: LOT 11 BLOCK 5 PLAT OF EDMONDS ACCORDING TO PLAT HEREOF RECORDED IN VOLUME I OF PLATS, PAGE 26, SNOHOMISH COUNTY, WA. PROPERTY TAX ACC. # LOT# 11: 43440050110003 LOT# 12: 43440050120002 LOT AREA: 14,400 SQ. FT. VX 2-1/2"X 2-1/2" AUTO } SPRINKLER CONNECTION ® 36' ARCH/F ARAnF GALV. RISER,FITTINGS AND GROOVED COUPLINGS ALL , 112" BRASS BALL DRIP TO DRAIN iI U IaRHVCL 6CVUIIVCi GRAVEL BEDDING 4" MJ X FLANGE DUCTILE IRON 90 4- MEGA LUG FITTING:: TO PREVENT FDC CONNECTION DETAIL NO SCALE UNDERGROUND PIPING GENERAL NOTES: 1. ALL MATERIALS & INSTAL L.ATIONS TO BE U.L. LISTED & SHALL CONFORM TO N.F.P.A. PAMPHLETS 413 & #24. 2. THRUST BLOCKS & RODDING SHALL CONFORM TO N.F.P.A. #24. 3. MINIMUM BURY SHALL BE 4'-0" 4. ALL WATER LINES FOR FIRE SPRINKLER SYSTEMS SHALL BE TESTED AT 200 psi FOR TWO (2) HOURS MINIMUM, 5. DUCTILE IRON PIPE SHALL BE USED WHEN PIPE PASSES UNDER BUILDING FOUNDATION OR FOOTING. 6. ALL EXTERIOR MATERIALS SHALL BE PROPERLY PROTECTED AGAINST EXPOSURE. 7. UNDERGROUND PIPING SHALL BE FLUSHED PER N.F.P.A. #24 BEFORE CONNECTING TO THE OVERHEAD FIRE SPRINKLER SYSTEM PIPING. RESUB J U N 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Non -Adjustable Non -Adjustable Indicator Post A-20808: Sizes 4"-14" A-20809: Sizes 16"-24" FEATURES: • UL Listed • FM Approved RESOURCES: RESUB J U N 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • Brochure (/sites/muellercompany.com/files/uploads/media/ULFM_Fire_Protection_Products_brch_ form12589_web.pdf) • Certification of Compliance (/sites/muellercompany.com/files/uploads/media/Certificateof Compliance- Post Indicators.pdf) SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM Figure 6H-2.2. Right -Hand Lane Closure on the Fat Side of an Intersection (TA-22 TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP (0-p1ional) �-- 01r3HM )IVD T avow A i i I,--; I,, al y .---- K r-J l` i I NOA 0�'0� ON3 (qpb on al) 4o'ter SeeTables 6144 and 614- for the meaning & the symbols aneVor letter codesused in this, figures RES U B ENGINEERING DIVISION J U N 13 2024 APPROVED AS NOTED %l/ (A/Q✓..ir,H,.44p 06/21 /2024 CITY OF EDMONDS vv DEVELOPMENT SERVICES DEPARTMENT I I t t --t � ROA WND OitK tilonah) WL i J6 ' E3 i Typical Application 22 I A ,r ST; MOST TURN RIG RT LANE ENDS MERGE �LM1 ROAD WORK. AHEAD NOTIFY COMMUNITY TRANSIT OF THE LANE CLOSURE .■40, Qi sv o (optional; RECEIVED MAY 17 2024 CITY OF EDMONDS M BuildingPermit.com CITY OF EDMONDS DEVELOPMENT Right -of -Way Application #1489598 - Fire Sprinkler Service Repair SERVICES DEPARTMENT Applicant First Name Last Name Company Name Douglas Spee Spee West Construction Number Street Apartment or Suite Number E-mail Address 307 Bell St. Suite 101 dspee@speewest.com City State Zip Phone Number Extension Edmonds WA 98020 (206) 284-7733 Contractor Company Name SPEE WEST CONSTRUCTION CO Number Street Apartment or Suite Number 307 Bell Street 101 City State Zip Phone Number Extension Edmonds WA 98020 (206) 284-7733 State License Number License Expiration Date UBI # E-mail Address SPEEWCC101 MF 2/21/2026 FD1 g561 95 dspee@speewest.com Project Location Number Street Floor Number Suite or Room Number City Zip Code County Parcel Number Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location corner of 3rd Ave. and Bell Street Property Owner First Name Last Name or Company Name Number Street Apartment or Suite Number City State Zip Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 5/16/2024 Submitted By: Douglas Spee Page 1 of 2 CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1489598 - Fire Sprinkler Service Repair Project Contact Company Name: Spee West Construction Name: Douglas Spee Email: dspee@speewest.com Address: 307 Bell St. Suite 101 Phone #: (206) 284-7733 Edmonds WA 98020 Project Type Activity Type Mixed Use Modification Scope of Work Excavation and Utility Work Project Name: Fire Sprinkler Service Repair Replace damaged side by side FDC and PIV that were accidentally knocked over by a passing Description of car. New posts will be bolted to existing flange fittings underground. Put one street sign back Work: up with replacement base and post. All new materials to match existing models and types. No road work or closure required. Make clean saw cuts for work to be done and patch back sidewalk. Project Details Impervious Surface Adding/Replacing less than 2,000 square feet of hard surface Tree Removal There are no significant trees being removed Page 2 of 2