Loading...
BLD2024-0816_Manufacturer_Specifications_and_Installation_Instructions_6.19.2024_3.41.56_PM_4332547Job Name: Tag# DAkfKkVN Submittal Data Sheet FDMQ12RVJU / RXL12QMVJU9 1.0-Ton Ducted Concealed Heat Pump System AIKIN r L JMJ" WAr)r.� -s Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Indoor Specifications Airflow Rate (cfm) Cooling Heating H M H M 392 332 392 332 L L 275 275 Sound(dBA) 33 33 Dimensions (H x W x D) (in) 9-5/8 x 27-9/16 x 31-1/2 Airflow Inlet (H x W) (in) 8-3/16 x 25-3/4 Weight (Lbs) 64 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 2.09 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating 1,144 1,106 Sound Pressure Level (dBA) 50 / 50 Dimensions (H x W x D) (in) 21-5/8 x 26-9/16 x 11-3/16 Weight (Lbs) 70 Efficiency Cooling Heating rEER 18 HSPF 10.8 11.7 COP 3.7 Performance Cooling (Btu/hr) Rated (Min/Max) 10,800 (6,500 / 13,200) Sensible @ AHRI 8,640 Standard Operating Range 50°F —115°F Extended Operating Range* -4°F —115°F Rated Cooling Conditions: Indoor: 80'F DB/67°F WB Outdoor: 95T DB/75°F WB *With field settings and wind baffle Heating (Btu/hr) 1: @ 47* Rated (Min/Max) 13,600 (6,300 / 17,000) 2: @ 17* Rated 8,600 3: @ S* Max: Capacity / COP 13,600 / 1.8 Operating Range -13°F — 65°F 1: Rated Heating Conditions: 2: Rated Heating Conditions: 3: Heating Conditions: Indoor: 70'F DB/60°F WB Outdoor: 47°F DB/43°F WB Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB Electrical 208/60/1 230/60/1 System MCA 13 13 System MFA 15 15 Compressor RLA 12 12 Outdoor fan motor FLA .17 .17 Outdoor fan motor W 20 20 Indoor fan motor FLA .73 .73 Indoor fan motor W 130 130 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 3/8 Drain (in) 1 Max. Interunit Piping Length (ft) 65.6 Max. Interunit Height Difference (ft) 49.2 Chargeless (ft) 32.8 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: January 2020 Page 1 of 4 FDMQ12RVJU Dimensional Data 7 DA T O a r+ CD a CD r+ T O r+ N CD C a CD O C r+ CD r+ J� \ 1 17�r 8-3/16 (208) o ; o� 2-3/8 (60) —0 Do wDQ 4-13/16 (123) c a C CL 8-3/4(222) I OD4r+ r-+ 33-7 8-1 A (207) r 5-3/8 (136) 1-1/2 (38; 2 x1-15/16=3-15/16 (2 x 50 = 100) J I W � w i to cm rn o o� cfl O w O v' O TI - O O O C n I n) v L I I 11-13/16 (300) Adjustable 5 5/16 (f or less 100 (2500) or more J '; a (A case without o the ceiling) CD N CD r+ W O O rn r:t rn 0 3 0 X. ry. 7 S 0 CJ1 O ? � CD 0 Q 3 x 1-1 5/16=5-7/8 (3 x 50 = 150) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: January 2020 Page 2 of 4 Rr 0 13/16 13116 (20) OUTDOOR AIR THERMISTOR 9116(1,1 1/2 (12.4) DRAIN OUTLET (I.D 05/8 (�l5.9mm) HOSE FOR CONNECTION WITH DRAIN JOINT) 'A,'B DRAIN OUTLET WHEN CONDUCTING CONCENTRATED DRAIN PIPING WORK, ATTACH THE SUPPLIED DRAIN CAPS. P,1IPJIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 47-1/4 (1200) UNIT: inch (mm) : FE< 4� n 0 L6 1-15/16 (50) 1-15/16 (50) 4-HOLES FOR FOUNDATION BOLTS 6-1/4 5/16 OR 318 (M8 OR M10) LIQUID STOP VALVE (q1/4 (06.4) CUT) GAS STOP VALVE (p3/8 (09.5) CuT) IN CASE OF REMOVING STOP VALVE COVER 3DO92206C 0 M 0 N 0 N i C 0 0 .m v v Y E 3 N Optional Accessories7-r-DAIKIN Indoor Unit — One Controller required Included Part Number Description BRCIE73 Wired Remote Controller BRC082A43 Wireless Remote Controller KRCS01 4B Remote Sensor DACA-CP2-1 Maxi Orange Condensate Pump (up to 49 ft head) DACA-CP3-1 Mini Condensate Pump (up to 33 ft head) KRPIC74 Wiring Adaptor KRP4A98 Mounting Plate DFBS27A13 MERV 13 Filter Kit AZAI6WSCDKA DKN Cloud Wi-Fi Adaptor KRP4A71 Group Control Adaptor PCB Outdoor Unit Included Part Number Description DACA-WB-1 Powder -Coated Wall -Mounted Bracket KEH067A41E Drain Pan Heater KKP937A4 Drain Plug for OD Unit KPW937F4 Low Ambient Wind Baffle / Air Adjustment Grille (09/12 MBH) KKG067A41 Back protection wire net KPS067A41 Snow hood (intake side late) (09 & 12) KPS067A42 Snow hood (intake rear plate) (09 & 12) KPS067A44 Snow hood (outlet) (09 & 12) Standard Equipment 7DA Part Number Description 2261089 Drain Pump 2261096 Float Switch Assy. External Static Pressure / Airflow Chart 7DAIKIN 0. 0.5(150) :A W N N H (max ESP) 9 u (. ESP) n 6 U 0.4000) h — ESP) 4_1 p W �s E4` (ESP at 0.4in.WON) d r X x w _ Il4nIW(iw YIF/do a ESP} 0.2 (50) mat \� 0. 4in.16000Pa)) H &ry sett' ESP t»`to 1 ytti (Factory setting ESP) Upper imil of ESP ESP „ (min ESP) 392 Air flow CFM (ni/min) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: January 2020 Page 4 of 4