BLD2024-0816_Manufacturer_Specifications_and_Installation_Instructions_6.19.2024_3.41.56_PM_4332547Job Name:
Tag#
DAkfKkVN
Submittal Data Sheet
FDMQ12RVJU / RXL12QMVJU9
1.0-Ton Ducted Concealed Heat Pump System
AIKIN
r
L JMJ"
WAr)r.�
-s
Complete warranty details available from your local dealer or at
www.daikincomfort.com. To receive the 12-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Quebec.
If product is installed in a commercial application, limited warranty
period is 5 years.
Indoor Specifications
Airflow Rate (cfm)
Cooling
Heating
H
M
H
M
392
332
392
332
L
L
275
275
Sound(dBA)
33
33
Dimensions (H x W x D)
(in)
9-5/8 x 27-9/16 x 31-1/2
Airflow Inlet (H x W) (in)
8-3/16 x 25-3/4
Weight (Lbs)
64
Outdoor Specifications
Compressor
Hermetically Sealed Swing Type
Refrigerant
R-410A
Factory Charge (Lbs)
2.09
Refrigerant Oil
PVE (FVC50K)
Airflow Rate (cfm)
Cooling
Heating
1,144
1,106
Sound Pressure Level (dBA)
50 / 50
Dimensions (H x W x D) (in)
21-5/8 x 26-9/16 x 11-3/16
Weight (Lbs)
70
Efficiency
Cooling
Heating
rEER
18
HSPF
10.8
11.7
COP
3.7
Performance
Cooling (Btu/hr)
Rated (Min/Max)
10,800 (6,500 / 13,200)
Sensible @ AHRI
8,640
Standard Operating Range
50°F —115°F
Extended Operating Range*
-4°F —115°F
Rated Cooling Conditions: Indoor: 80'F DB/67°F WB
Outdoor: 95T DB/75°F WB
*With field settings and wind baffle
Heating (Btu/hr)
1: @ 47* Rated (Min/Max)
13,600 (6,300 / 17,000)
2: @ 17* Rated
8,600
3: @ S* Max: Capacity / COP
13,600 / 1.8
Operating Range
-13°F — 65°F
1: Rated Heating Conditions:
2: Rated Heating Conditions:
3: Heating Conditions:
Indoor: 70'F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB
Electrical
208/60/1
230/60/1
System MCA
13
13
System MFA
15
15
Compressor RLA
12
12
Outdoor fan motor FLA
.17
.17
Outdoor fan motor W
20
20
Indoor fan motor FLA
.73
.73
Indoor fan motor W
130
130
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in)
1/4
Gas (in)
3/8
Drain (in)
1
Max. Interunit Piping Length (ft)
65.6
Max. Interunit Height Difference (ft)
49.2
Chargeless (ft)
32.8
Additional Charge of Refrigerant (oz/ft)
.21
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Creation Date: January 2020 Page 1 of 4
FDMQ12RVJU Dimensional Data 7 DA
T
O
a
r+
CD
a
CD
r+
T
O
r+ N
CD C
a CD
O
C
r+
CD
r+
J�
\ 1 17�r
8-3/16 (208)
o ;
o�
2-3/8 (60)
—0
Do
wDQ
4-13/16 (123) c a
C
CL
8-3/4(222)
I
OD4r+
r-+ 33-7
8-1 A (207) r
5-3/8 (136)
1-1/2 (38;
2 x1-15/16=3-15/16
(2 x 50 = 100)
J
I
W
�
w
i
to
cm
rn
o
o�
cfl
O
w
O
v'
O
TI
-
O
O
O
C
n
I
n)
v
L I
I
11-13/16
(300)
Adjustable
5 5/16 (f
or less
100 (2500)
or more
J '; a
(A case without
o
the ceiling)
CD
N CD
r+
W
O
O
rn
r:t
rn 0 3 0
X. ry. 7
S 0
CJ1 O ? �
CD 0
Q
3 x 1-1 5/16=5-7/8
(3 x 50 = 150)
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Creation Date: January 2020 Page 2 of 4
Rr
0
13/16
13116 (20)
OUTDOOR AIR THERMISTOR
9116(1,1
1/2 (12.4)
DRAIN OUTLET
(I.D 05/8 (�l5.9mm) HOSE FOR CONNECTION
WITH DRAIN JOINT)
'A,'B DRAIN OUTLET
WHEN CONDUCTING CONCENTRATED
DRAIN PIPING WORK, ATTACH THE
SUPPLIED DRAIN CAPS.
P,1IPJIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 (1200)
UNIT: inch (mm)
: FE<
4�
n
0
L6 1-15/16 (50)
1-15/16 (50)
4-HOLES FOR FOUNDATION BOLTS 6-1/4
5/16 OR 318 (M8 OR M10)
LIQUID
STOP VALVE
(q1/4 (06.4) CUT)
GAS
STOP VALVE
(p3/8 (09.5) CuT)
IN CASE OF REMOVING
STOP VALVE COVER
3DO92206C
0
M
0
N
0
N
i
C
0
0
.m
v
v
Y
E
3
N
Optional Accessories7-r-DAIKIN
Indoor Unit — One Controller required
Included
Part Number
Description
BRCIE73
Wired Remote Controller
BRC082A43
Wireless Remote Controller
KRCS01 4B
Remote Sensor
DACA-CP2-1
Maxi Orange Condensate Pump (up to 49 ft head)
DACA-CP3-1
Mini Condensate Pump (up to 33 ft head)
KRPIC74
Wiring Adaptor
KRP4A98
Mounting Plate
DFBS27A13
MERV 13 Filter Kit
AZAI6WSCDKA
DKN Cloud Wi-Fi Adaptor
KRP4A71
Group Control Adaptor PCB
Outdoor Unit
Included
Part Number
Description
DACA-WB-1
Powder -Coated Wall -Mounted Bracket
KEH067A41E
Drain Pan Heater
KKP937A4
Drain Plug for OD Unit
KPW937F4
Low Ambient Wind Baffle / Air Adjustment Grille (09/12 MBH)
KKG067A41
Back protection wire net
KPS067A41
Snow hood (intake side late) (09 & 12)
KPS067A42
Snow hood (intake rear plate) (09 & 12)
KPS067A44
Snow hood (outlet) (09 & 12)
Standard Equipment 7DA
Part Number
Description
2261089
Drain Pump
2261096
Float Switch Assy.
External Static Pressure / Airflow Chart 7DAIKIN
0.
0.5(150)
:A
W
N
N
H
(max ESP)
9 u (. ESP)
n
6
U
0.4000)
h
— ESP) 4_1
p
W
�s
E4`
(ESP at
0.4in.WON)
d
r
X
x
w
_ Il4nIW(iw
YIF/do a ESP}
0.2 (50)
mat
\�
0. 4in.16000Pa))
H
&ry sett' ESP
t»`to
1 ytti
(Factory setting ESP)
Upper imil of ESP
ESP
„
(min ESP)
392
Air flow
CFM (ni/min)
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Creation Date: January 2020 Page 4 of 4