BLD2024-0814_Mechanical_Plan_6.19.2024_10.18.26_AM_4331536GENERAL NOTES 1. FOR LINE TYPES, SYMBOLS & ABBREVIATIONS SEE LEGEND ON MP-001. 2. FOR CONNECTION TO STRUCTURE & PIPE SUPPORT SEE DETAILS 1 & 2 ON SHEET MP301. 3. SEE FIXTURE SCHEDULE ON MP-001 FOR ADA & STANDARD RIM HEIGHTS FOR WC-1. 4. CONTRACTOR SHALL PATCH FLOORS, WALLS & CEILINGS TO MATCH NEW CONSTRUCTION PER ARCHITECTS SPECIFICATIONS. 5. COORDINATE REQUIRED SLAB CUTS FOR NEW PLUMBING LINES WITH ARCHITECT PRIOR TO CONSTRUCTION. 6. EXISTING PIPING SIZES AND LOCATIONS IS PER RECORD DRAWINGS, PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY FOR EXACT SIZE, LOCATION & INVERT ELEVATION OF EXISTING WASTE LINE & COORDINATE WITH PLUMBING ENGINEER FOR ANY CHANGES NEEDED. 7. FOR WATER HAMMER ARRESTOR, SEE DETAIL e P-30 :(E O 8. FOR SINK CONNECTION, SEE DETAIL e P-30 ALL GENDER TLT (E) 3/4" CW 9. FOR CLEANOUT, SEE DETAIL Y1 24 P-30 2 O (E) 2" V 10. FOR TRAP PRIMER CONNECTION, SEE DETAIL e P-30 (E) 3/4" HW --� — r — 11. FOR EXHAUST FAN SUPPORT, SEE DETAIL P730 (E) 1-1/2" V —I- J 12. FOR EXHAUST FAN ROOF CAP, SEE DETAIL P830 O I O --� DEMOLITION NOTES E 2 W !� I �(E) 1/2" TP 9 O(E) 1/2" CW — — O (E) WATER CLOSET AND ASSOCIATED PIPING TO REMAIN. OO � I O 1 (E) LAVATORY AND ASSOCIATED PIPING TO REMAIN. 5 O (E) FLOOR DRAIN AND ASSOCIATED PIPING TO REMAIN. I O4 (E) INSTANTANEOUS ELECTRIC WATER HEATER AND ASSOCIATED PIPING TO REMAIN. (E) TRAP PRIMER - - - J � O5 (E) TRAP PRIMER TO REMAIN O(E) EXHAUST FAN TO REMAIN. O (E) 1/2" CW (E) 2" V O7 REMOVE (E) 1/2" CW AND REPLACE WITH (N) 1-1/2" CW AND RECONNECT TO (E) COLD WATER MAIN AND (E) 1/2" TO (E) WATER CLOSET. (E)1/2" CW (E) 3" W O8 REMOVE (E) 1/2' CW AND REPLACE WITH (N) 3/4" CW AND RECONNECT TO (E) 3/4" CW. NORTH O SAW CUT FLOOR SLAB REQUIRED TO INSTALL NEW FIXTURE AND / OR PIPING TO CONNECT EXISTING. LEVEL 1 WORKROOM/BATHROOM MECHANICAL & PLUMBING DEMOLITION PLAN SCALE: 1/2"=11-011 1 CONSTRUCTION NOTES O 2" W DN. O2 1/2" TP DN. OCONNECT (N) 3" W TO (E) WASTE. BENCH WITH O SAW CUT SLAB REQUIRED TO INSTALL NEW FIXTURE AND PIPING TO CONNECT TO EXISTING CABINETS ABOVE O(N) EXHAUST FAN TO CONTROL VIA LIGHT SWITCH WITH FIVE-MINUTE DELAY TO TURN OFF. ORETROFIT (E) EXHAUST FAN TO CONTROL VIA LIGHT SWITCH WITH FIVE-MINUTE DELAY TO TURN OFF. O8x6 EXHAUST DISCHARGE OPENING SIDE. - - - L - - - - - - (E) WINDOW DISPLAY O80 EXHAUST DUCT UP TO ROOF. PROVIDE CAP WITH BUILT-IN DAMPER AND BIRDSCREEN AT TERMINATION. 1/2" CW 22 WCO L 1 (E) LL GENDER TLT (N) STAFF TLT 24 2„ W 40 20 1-1/2n �/ r-1L7L__—T __JCA—r V I I I (E) 3/4" HW 1E 3/4WCW (E) 2 V - - - - I I I (E) 1 1/2" V I I I (E)1 1/2" V 8 \ _I_ cl- 1/2" V 4 ---�� / 2"W FD 2 & 7 1/2" TP 1 I �(E) 2" W — EF O5 (E) STORAGE ROOM (E) 1/2" TP 3 - -- 1 / C 21 3/4" CW I �� /WC 6 I TP 5 I I WDHAWCO I — — F i — �� M ' JQ 110 James St., Suite 106 Edmonds, WA 98020 �� �'� O Phone:425.458.9700 J — — — — — — — — — — — — — — — — - z Email: cadd@designwesteng.com - 6776 0DESIGN WEST ENGINEERING (E)2"V 2" GISTEg1 SSjDNAL� MECHANICAL • ELECTRICAL • ENERGY CONSULTANTS (E) 1/2" CW 1-1/4" CW 4 3/4" CW (E) 3" W CONNECT TO NEAREST NORTH (E) 3/4" CW IN STAFF 1 LOUNGE WO KROOM LEVEL 1 WORKROOM/BATHROOM MECHANICAL & PLUMBING REMODEL PLAN SCALE: 1/211_11-011 L RESERVED FOR BUILDING DEPT STAMP v 0 � C) M E O 00 M N Q 0 In Q r4 N rN V M o `° 3 l w d0 � 0 o NFU 0)Q'- 0 0 '� J 41 O Of N O 00 }+ L cl o o c o o v > W c/) V J W c ! > o CD J —af W O W^�, U U) N M N REVISION SCHEDULE # DESCRIPTION DATE 0 FIXTURE CHANGE 4/5/24 ,106 NO. 22-268 DATE 05/02/2024 DRAWN KN REVIEWED Si SHEET NAME BLDG H WORKROOM BATHROOM M&P PLAN SHEET NO. MP-201 22-268