Loading...
Building Permit (2)Type: RESIDENTIAL BLDG Subtype: NEW SINGLE FAMILY I Status: ISSUED Parcel No: 00513100002410 Site Address: 15604 75TH PL W EDMONDS,WA 98026 Subdivision: SP AFN 200010235001, 005131 Lot: 0 Fire Sprinklers: Yes Lot Area: Zoning: Valuation: $582,511.68 Occupancy Type: R-3/U Construction Type: VB Code Edition: 2018 No. Stories: 1 # of Dwelling Units: 1 Scope of Work: KOH- ESLHA NEW SFR M INLC P SEP WA State Contractor L & I #: DLHIN**072B5 Applied: 5/24/2023 Issued: 6/26/2024 Final: Expiration Date: 6/26/2026 Issued by: JOK CONTACTS NAME TYPE NAME ADDRESS PHONE EMAIL APPLICANT NAZIM NICE 3104 WESTERN AVENUE #107, (206)204-0490 NAZIM@MOTION-SPACE.COM SEATTLE WA 98121 CONTACT MOTIONSPACE 3104 WESTERN AVENUE #107, (206)204-0490 jack@motion-space.com ARCHITECTURE + DESIGN SEATTLE WA 98121 CONTRACTOR D L H INC 44021 SE TANNER ROAD, STE A, (425)888-1853 office@patriciabrennanarchitects.com NORTH BEND WA 98045 15324 MERIDIAN DR SE, OWNER HARTANAH KL LLC LYNNWOOD WA 98087 DESCRIPTION ACCOUNT AMOUNT PAID PAID DATE RECEIPT # 6/25 22024: BAL OF DEPOSIT XFER 001.000.62.524.20.41.0 $$666.25 $666.25 12/29/23 R33561 TO BUILDING PERMIT BAL BLD - RES VALUE BASED FEE 001.000.345.83.000.00 $666.25 $666.25 6/25/24 R38117 BLD - RES VALUE BASED FEE 001.000.345.83.000.00 $3,248.75 $3,248.75 6/26/24 R38136 BLD - RES VALUE BASED REVIEW 001.000.345.83.000.00 $3,327.75 $3,327.75 6/29/23 R29645 CITY TECHNOLOGY FEE - PER 001.000.321.99.100.00 $45.00 $45.00 6/29/23 R29645 PERMIT DEPOSIT AT FULL APP FOR PEER 001.000.62.524.20.41.00 $3,500.00 $3,500.00 6/29/23 R29646 REVIEW DEPOSIT AT RE -SUB FOR ADDL PEER 001.000.62.524.20.41.00 $2,000.00 $2,000.00 12/29/23 R33561 REVIEW DEPOSIT FOR PEER COMPLETENESS 001.000.62.524.20.41.00 $750.00 $750.00 6/29/23 R29646 REVIEW ENG - INSPECTIONS 001.000.345.83.400.00 $1,638.00 $1,638.00 6/26/24 R38136 ENG - PEER REVIEW DEPOSIT 001.000.245.963 $712.50 $712.50 6/26/24 R38136 ENG - PEER REVIEW DEPOSIT 001.000.245.963 $2,992.50 $2,992.50 6/26/24 R38136 ESLHA ADMINISTRATIVE FEE 001.000.345.83.000.00 $2,724.00 $2,724.00 6/29/23 R29646 MECHANICAL BASE PERMIT FEE 001.000.322.10.000.00 $57.00 $57.00 6/26/24 R38136 NEW SINGLE FAMILY MECHANICAL 001.000.345.83.000.00 $340.00 $340.00 6/26/24 R38136 SYSTEMS PARK IMPACT - RES ADMIN FEE 001.000.345.83.000.00 $60.00 $60.00 6/26/24 R38136 Printed: Wednesday, June 26, 2024 1:52:42 PM 1 of 5 -RESIDENTIAL BLDG PermitCity - • • • • 98020 1 1 . 1 www.edmondswa.gov DESCRIPTION ACCOUNT AMOUNT PAID PAID DATE RECEIPT # PARK IMPACT - SINGLE FAMILY 332.100.345.85.000.00 $2,734.05 $2,734.05 6/26/24 R38136 RECORDING FEE - CITY 001.000.345.89.030.00 $126.00 $126.00 1/25/24 R34406 RECORDING FEE - SNOHOMISH 001.000.345.89.030.00 $306.50 $306.50 1/25/24 R34406 COUNTY STATE BUILDING CODE SURCHARGE 001.000.237.150 $6.50 $6.50 6/26/24 R38136 - RES STORMWATER ENGINEER - REVIEW 001.000.345.83.400.00 $1,036.00 $1,036.00 6/26/24 R38136 STORMWATER GFC - SFR UNDER 422.000.379.00.000.00 $799.00 $799.00 6/26/24 R38136 5000 - 12.31.23 AND PRIOR TRANSPORTATION IMPACT - 001.000.345.83.400.00 $60.00 $60.00 6/26/24 R38136 ADMIN FEE - SFR TRANSPORTATION IMPACT FEE - 112.502.345.86.000.00 $6,249.14 $6,249.14 6/26/24 R38136 SFR TOTALS: $34,045.19 $34,045.19 CONDITIONS CONDITION TYPE STATUS NOTES CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EACH LEVEL IN FOR CARBON MONOXIDE SYSTEMS NEW CONSTRUCTION AND IN EXISTING DWELLINGS WHEN ALTERATIONS, REPAIRS OR INFORMATION ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED. ELECTRICAL PERMIT FOR Obtain Electrical Permit from State Department of Labor and Industries 425-290-1309. NFORMATION As required by Ord 3632 the geotechnical engineer of record shall monitor this site during construction for compliance with the recommendations in the geotechnical report including site excavation, shoring, soil support for foundation, including piles, soil bearing capacity, sub drainage installation, soil compactions, and other geotechnical aspects of the construction. Specific recommendations contained in the approved geotechnical report must be implemented by the owner. The geotechnical engineer shall make written dated reports on the progress of the construction and submit the report to the City on a weekly basis until all site grading, drainage, foundation and associated ground work is complete. Omissions or deviations from the approved geotechnical report and or approved plans or specs shall be highlighted and immediately submitted in a separate letter to the City for review. The City shall be advised in writing of work stoppages of FOR more than one week. In addition to the geotechnical monitoring special inspections ESLHA REPORTS INFORMATION based on the provisions of IBC Section 1704 are required when specified. Other special inspections may also be required by the geotechnical engineer, architect, or structural engineer of record. At the completion of final site grading and all permitted structures a final geo technical report prepared by the geotechnical engineer shall be submitted to the City. This report shall contain a statement that, based upon his/her professional opinion, site observations, and testing during the monitoring of the construction, the completed development substantially complies with the recommendations in the geotechnical report and with all geotechnical related requirements. Any deviations or omissions in the report, plans, or specifications that occurred during construction shall be addressed separately. Occupancy, final approval, or release of the bond for the project shall not be granted until the report has been reviewed and accepted by the Building Official. FOR In addition to the required pressure relief valve an approved listed expansion tank shall EXPANSION TANK INFORMATION be installed on all hot water tanks per UPC 608. Printed: Wednesday, June 26, 2024 1:52:42 PM 2 of 5 'RESIDENTIAL BLDG Permit PERMIT NUM City of Edmonds 121 5th Ave N, Edmonds WA 98020 www.edmondswa.gov - MJL�LD2023-06140 FOR Request final Fire Department Inspection 425-775-7720 or schedule online via FIRE FINAL INSPECTION INFORMATION mybuildingpermit.com Approval of this foundation design is conditional subject to inspection of existing site soil FOR conditions. Retaining walls must be designed and constructed to resist the lateral FOUNDATION BEARING INFORMATION pressure of the retained material. Provisions must be made for the control and drainage of surface water around buildings. GAS PIPE TEST FOR Gas pipe test must be observed by City Building Inspector, affidavits shall not be accepted NFORMATION Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its FOR officials, employees, and agents from any and all claims for damages of whatever nature, HOLD HARMLESS INFORMATION arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. HOSE BIBBS FOR Hose Bibbs are required to have a permanently affixed anti -siphon device installed. NFORMATION LOT LINES STAKED FOR Lot line stakes must be in place at the time of foundation setback inspection. NFORMATION Installation, use and maintenance of equipment and components shall be per MANUFACTURER SPECS FOR manufacturers specifications, installation instructions, and applicable state codes. INFORMATION Provide manufactures installation instructions on site for Building Inspector. Maximum Height 25 feet. The agent or contractor shall set up the equipment; establish the datum point and the point of average grade. Call for inspections to verify. These MAXIMUM HEIGHT O items must be consistent with the approved plan. If the proposed height of a building is INFORMATION within 12 inches of the maximum height permitted for the zone an elevation survey is required. Final approval on a project or final occupancy approval must be granted by the Building OCCUPANCY FOR Official prior to use or occupancy of the building or structure. Check the job card for all INFORMATION required City inspections including final project approval and final occupancy inspections. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly visible from the street POST ADDRESS FOR or road fronting the property. Address numbers shall be Arabic numerals or alphabet INFORMATION letters Numbers shall be legible from the public way, at least 6 inches high with a .75inch min stroke width on a contrasting background. The issuance of this permit in no way constitutes approval from any other agencies REGULATING AGENCIES FOR having regulatory authority over the facility and this construction activity. It is the INFORMATION responsibility of the property owner to obtain any and all such required approvals. REQUIRED SPECIAL FOR INSPECTIONS INFORMATION FOR SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING, SEPARATE PERMITS REQUIRED INFORMATION FOR FOR ROOFTOP SOLAR (Engineered Design Required) INFORMATION FOR Heat pumps, AC units and similar equipment greater than 36 inches in height are not SIDE YARD EQUIPMENT INFORMATION allowed within required building setbacks. Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of FOR 7:OOam to 6:OOpm on weekdays and 10:OOam and 6:OOpm on Saturdays, excluding SOUND AND NOISE INFORMATION Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Printed: Wednesday, June 26, 2024 1:52:42 PM 3 of 5 'RESIDENTIAL BLDG PermitCity PERMIT NUM •Edmonds -0640 www.edmondswa.gov• Special inspections have been called for on this project and are noted on the approved FOR construction plans. It is the owner and or contractors responsibility to ensure that reports INFORMATION are provided to the City on a weekly basis. Special Inspections: Please see cover page of plan set SPECIAL INSPECTION BUILDING DIVISION ? Auger Cast Concrete Piles FOR ? High Strength Concrete INFORMATION ? Soils ? Structural Observation by design professional ? Structural Steel/Welding ? High Strength Bolting FOR Submit all special inspection reports to the City Building Official on a weekly basis. INFORMATION Special Inspections: Please see cover page of plan set SPECIAL INSPECTION REPORTS ? Auger Cast Concrete Piles FOR ? High Strength Concrete INFORMATION ? Soils ? Structural Observation by design professional ? Structural Steel/Welding ? High Strength Bolting FOR Pursuant to UPC 605.2 a water service shutoff shall be installed on the water line as it WATER SERVICE SHUTOFF INFORMATION enters the building. Installer shall provide the manufacturer installation, operating instructions, and a whole FOR WHOLE HOUSE FAN house ventilation system operation description. A label shall be affixed to the whole INFORMATION house timer control that reads "Whole house ventilation, see operating instructions". INSPECTIONTYPE INSPECTOR COMPLETED RESULT NOTES A-1 BUILDING PRECON B-1 SETBACKS B-2 FND DAMPPROOFING B-2 FOOTINGS B-2 FOUNDATION WALL B-2 RETAINING WALL B-2 SLAB INSULATION B-3 EXT WALL SHEATHING B-3 EXTERIOR INSULATION B-3 HYD PRESSSURE TEST B-3 MECH ROUGH IN B-3 ROOF SHEATHING B-3 UNDERFLR FRAMING B-4 DRYWALL FASTENING B-4 FRAMING B-4 HEIGHT VERIFICATION Printed: Wednesday, June 26, 2024 1:52:42 PM 4 of 5 ' : '- rmit 1AAM PERMIT NUM City of Edmonds w- 121 5th Ave N, Edmonds WA 98020 BLD2023-06410 www.edmondswa.gov B-4 INTERIOR SHEAR B-4 SHOWER PAN B-5 INSULATION ENERGY B-7 BUILDING OTHER INSP X-3 BUILDING FINAL" B-5 BLDG SPECIAL Special Inspections: Please see cover page of plan set INSPECTION ? Auger Cast Concrete Piles ? High Strength Concrete ? Soils ? Structural Observation by design professional ? Structural Steel/Welding ? High Strength Bolting A-1 TESC AND MOBILIZE E-3 RET WALL DRAIN OUTFALL E-3 STRM CONVEYANCE E-3 STRM COVENANT E-3 STRM FOOTING DRAIN E-4 ACCESS WIDTH SLOPE E-4 WATER SERVICE LINE E-5 DRIVEWAY SLOPE E-5 ENG SPECIAL INSPECTION E-7 DWY APPROACH E-9 COMPOST AMEND E-9 PROJECT ASBUILTS X-2 ENGINEERING FINAL NOTE TO INSPECTOR: DEED OF DEDICATION AND ENCROACHMENT AGREEMENT TO BE RECORDED PRIOR TO FINAL CERTIFICATE OF OCCUPANCY. A-1 ENGINEERING PRECON NOTE TO INSPECTOR: SEE PRECON DOC X-1 PLANNING FINAL LANDSCAPE INSP. E-3 STRM TIGHTLINE NOTE TO INSPECTOR: DEFERRED SUBMITTAL FOR BNSF APPROVAL OF STORM OUTFALL. Printed: Wednesday, June 26, 2024 1:52:42 PM 5 of 5