Loading...
APPROVED BLD BLD2020-0581+Energy_Calculations+6.5.2020_2.43.08_PMPrescriptive Energy Code Compliance for All Climate Zones in Washington �Pr%iRct Information Contact Information UF-KR.l5T1 N -tJ oN ilZ This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative L('�� h Date All Climate Zones R Valuea 1-1-Factor" Fenestration 1-1-Factor" n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC"•B n/a n/a Ceilingk 4V 0.026 Wood Frame Wall""" 21 int 0.056 Mass Wall R-Value! 21/21" 0.056 Floor 309 0.029 Below Grade Wall"'m 1 10/15/21 int + TB 0.042 Slabd R-Value & Depth 10, 2 it n/a *Table R402.1.1 and Table R402.1.3 Footnotes mctuueu on 1aye, BLD2020-0581 RECEIVED Jun 05 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit- 1.5 credits ed floor area with less than 300 square feet of fenestration Dwelling units less than 1500 square feet in condition area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. 02. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. F]3. Large Dwelling Unit 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. A 4, Additions less than 500 square feat:.5 credits Table R406.2 Summary n,......:..a:.... Credit(s) V UU11 la uw111JUU11 Efficient Building Envelope I lb Efficient Building Envelope 1 b 1..00 1 1c Efficient Building Envelope 1c 2. 1d Efficient Building Envelope ld 0.55 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a 3b 3c 3d High Efficiency HVAC_ 3a High Efficiency HVAC 3b High Efficiency HVAC 3c High Efficiency HVAC 3d 1.0 1.0 1.5 1.0 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 50 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions REVIEW D BY f OF EDMONDS a El r� 12 D t� `1200 kwh 0.0 0.00 2015 WASHINGTON STATE ENERGY CODE AND 2015INTERNATIONAL RESIDENTIAL CODE RESIDENTIAL ENERGY AND VENTILATION KMMITTAL FORM Applies M V 99dy Application # Job Type. ❑ New 41 Addition ❑ Remodel Date. jp rj Zd2a Conditioned Square Feet: Occupancy. ❑ Single Family/Duplex ❑ Residential Care/ Assisted Living/ Adult FamilyHome MINIMUM INSULATION REQUIREMENTS —These may need to be Increased based on ENERGY CREDITS selected below. Glazing U-Factor Door U-Factor Rafter/Joist Vaulted Ceilings A0 Other Ceftas We& Above Grade Walls Below Grade Floors Over Unheated Space Slab On Grade Vertical Overhead 030 0.50 030 R-38 R49 or R MADV R 21 INT R 10 CI Exterior OR R 15 CI InteriorgR R-S CI+R.13 BattAH R30 R-10 U-FEquactor lent -Factor 030 0.50 030 0.026 0.026 0A56 R 21 Batt w/TB Stab 0.042 0.029 NIA PROPOSED M+.�r•• ran-.,e arvc .op nams.e tngn: c:eamg urea MT=2c5at16'0aw/R-101iealma Q=Cmtlmawa Rigidk atim TB—Th=ai ]Break ENERGY CREDITS— See the Energy Credits descriptions on the back of this form and indicate which options win be used. s'Small Addition 0.5 pts required Small Dwelling Unit / Medium Addition 15 pts required Medium Dwelling Unit / Large Addition 35 pts required Large Dwelling Unit 4.5 fits required (Additions <500 sx) (Dwellings < 1500 s.£ w/ glazing <300 s.£, or Additions < 1,500 s.£) (Alt Dwellings not Small or Large, or Additions> 1,500 s.£) (Dwellings> 5.000 a.E) TOTAL POINTS = IF In (0.5 fits) ❑ lc (2.0 pis) ❑ 2a (0.5 pts) ❑ 2c (1.5 pts) ❑ 3b (1.0 pts) ❑ 3d (1.0 pis) ❑ 5a (0.5 pts) ❑ 5c (1.5 pts) ❑ 6 (0.5 pts) ❑ lb (1.0 pts) ❑ Id (0.5 pts) ❑ 2b (1.0 pts) ❑ 3a (1.0 pts) ❑ 3c (1.5 pts) ❑ 4 (1.0 pts) ❑ 5b (1.0 pts) ❑ 5d (0.5 pts) VAPOR RETARDERS — Select the Vapor Retarder to be used at each location. VENTILATION SYSTEM —Select a System Type and complete the Ventilation Rate calculation on the back of this form. E Not Applicable (Additions less than 500 s.L) VEN MATATION RATE = CFM ❑ Whole -House Exhaust Fan with fresh airport (net 4 sq. in. minima n opening) at each habitable room A timer operates an exhanstfan which pulls outside air through air inlets located in each habitable room. ❑ Integrated System with fresh air duct connected to return air duct of forced -air heating system. A timer operates the furnace blower and a motorized outside air inlet damper to distribute outside air through the heating ducts ❑ Supply Fan with fresh air duct connected to supply air duct or return air duct of forced -air heating system, or other deers. A timer operates a sWplyfan connected to an outside air inlet to distribute outside air through the heating ducts or other ducts. ❑ Heat Recovery System A timer operates a heat recovery ventilator (BRF9 to distribute outside air to habitable rooms through dedicated ducts. ❑ Designed System per IMC with calculations and/or performance testing. Includes:. ❑ Whole house fan ❑ FYesh air ports 7yptcally such systems must be designed installed, tested and baltmced by a mechanical engineer or miterHVACprofessiona[ Continuously operating ventilation systems shall provide the minimum flow rates specified in Table M1507.33(I). Intermittently operating ventilation systems shall provide flow rates per Table M150733(I) as modified by Table M15073.3(2). AIR TESTING —These tests mast be performed on -site with specialized equipment. ❑ Duct Leakage Test Required when space -conditioning equipment is installed altered or replaced Cnclufing replacement ofair handler, outdoor unit ofair condflumer/heat pump, cooling or heating coil, orfwwace heat exchanger). Some exceptions apply. 0 Building Leakage Test Requiredfor additions > 500 sf and new construction.