APPROVED BLD ENG PLN BLD2020-0581+Architectural_Plan+8.3.2020_6.45.45_PMi rl yT� � � ric- t� T&«1 ALLTic. MEAyu�
c�o2tii+.t� To A r F Z.ovev MA�ts
EDMONDi 5'(C�NDI�tz.D n�'fal� AND ,4U�
0114M M?,MWtz.eo�r 'MA1 MAY OF, tTQ,uttZEp
DUl21Ntx CON4512UC'[iDN,
MAI,��AL-
CIO kiTrNTt
Option 4
Import topsoil.
• Enter lettered areas from site plan where this option will be used:
A
• Enter combined square footage of lettered areas in thousands
(example: for 4,525 sq ft, enter 4.525; for 500 sq t3, enter 0.5)
• Multiply combined square footage by 25 and enter product in box C:
C Y�- pubic Yards
AMOUNT OF IMPORTED TOPSOIL. NEEDED FOR THESE AREAS
Order These Amounts: Enter amount in Box A: • 10 Cubic Yards of Compost
Enter amount in Box C
Cubic Yards of Topsoil
Note: MR S is triggered on sites with more than 2,000 sq. ft. of new, replaced, or new plus replaced impervious
surface, or 7, 000 sq. ft. or greater of land disturbing activity.
..:...:...,:.:.... r4....,. -
�1 tit-l'C rA"4)
t7A-TV M Mrtw—
100.0
g► Ioj• o'
C. tot. of
d. lot- 0
I Z%5.1r> MAX,
DESIGN CRITERIA for EDMONDS
Min Roof Snow Load
25 psf (non -reducible)
Ground Snow Load
25 psf
Seismic Design
Category D 1
Wind Speed
85 mph (Basic) 110 mph� (Ultimate)
Wind Exposure
B, C, D (varies, contact staff)
Winter Design Temp
27 degrees
Mean Average Temp
50 degrees
OBTAIN ELECTRICAL PERMIT FROM
STATE LABOR & INDUSTRIES
2' x 2" WOOD/STEEL
FILTER FABRIC SECL
TO 2' x 2" 14 GA
WIRE FABRIC EQUAL
NATIVE BACKFILL MATERIAL
FILTER FABRIC MATERIAL IN counNOUs m"
USE STAPLES OR WIRE RINGS TO ATTACH'
FABRIC TO WIRE
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER
EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON
2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS
ACTIVITY- BEFORE OTHER WORK CAN BEGIN
REVISION DATE
CITY OF EDMONDS FILTER FABRIC FENCE JMUARY 2018
FILTRATION SYSTEMS
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
Fst 1890 APPROVED BY: R. ENGLISH f. _ ER-900
a
L 01 I) r L-A-T 4J ;
A qj
41h
tK � V
O >1` tZEM 0� l D x`th
I.
Q
Ek. t A, N 60 60 P o°
TYp.Nlk?
I� w
•A(Kt-
7 x l4ofF,. F kO O T rolzc"
2a FROItt 12 t+, 6 a - r rza �T w coo r-r -n- Aa-N
o
"o 513• tr ?jo" IKf0 0-�Ff-fPJACK-- (20* EQvt`IT077
�
115 . ... .
��•
ht4��►o0.0' -. '
C V ";7
-
lOd�a' o
_ M
APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
O E
O O
00
Ol
-- ----- r-—-—-—-—-—-—-—---—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—- — - — - —, N
z v�
I O
SPECIAL INSPECTOR REQUIRED FOR THE STRUCTUAL EPDXY z o 0
L--------------------------------------------------------I cnt•-ta
� W �
OWNERS:
W
JERRY & FARAH MURRAY
z
v)
630 ALDER STREET
O
o
EDMONDS 98020
z
a
425-770-4073
Q
_�v
`"
N
shredbettv360@hotmaii.com
TAX No: 0043 4209 400 900
LEGAL: CITY of EDMONDS BLK 094
LOTS 9 & 10 w/ 3FEET OF LOT 11.
BUILT: 1953
SCOPE of PROJECT:
ADD BEDROOM BUMP-OUTTO REAR.
ADD (2) BAY
WINDOWS TO FRONT w/ FOUNDATIONS
BUT UNDER
EXISTING EAVES. NEW FRONT PORCH
ROOF.
REMOVE 160 SQ FT'SUNROOM' FROM REAR.
LATER ROOF OVER REMAINING PATIO
AREA.
ZONE: RS — W 0
LOT SIZE: 6969.3 SQ FT 110 ft x 63 Ft.
LOT COVERAGE: EX REAR GARAGE:
367.5 SQ FT
EX RES/GARAGE:
1345.
(REMOVE SUNROOM)
(160.)
NEW LIVING / BAYS:
384.5
1934,5 SQ FT
IMPERVIOUS: EX. DRIVE, RES/GARAGE
EX. REAR GAR/ WALKS
1952 SQ FT
(REMOVE SUNROOM)
(160.)
REMAINING PATIO
162. SQ FT
P NEW:
+ 384.5
2338.5 SQ FT 33.5
GRADING: 15-20 CU YDS. USED ON SITE.
Hf-AT, EX • JABS FUZ4
I' -
CONTACT DURING PERMITING:
KRISTIN HANSON
HANSON DESIGN
652 ALDER ST
EDMONDS 98020
425-774-7129
hansondesign@hotmail.com@hotmail.com
CONTRACTOR:
TABLE of CONTENTS:
1.
SITE
2.
EXISTING PLAN / ELEVATIONS
3.
PROPOSED PLAN / FOUNDATION
RES U B
4,
ROOF / SECTIONS
5.
ELEVATIONS
Aug 04 2020
6.
GENERAL NOTES
CITY OF EDMONDS
DEVELDEPARTMMENTENT OPMENCES
3 5 % µArx
'7% MAX,,
APPROVED BY PLANNING
Aug 11 2020
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application, regardless
of whether such building, structure or condition is
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate
enforcement action.
Zone RS-6
Corner
Flag _
Setbacks:
Required
Proposed
Street (N)
:20 :::: _
::20
:
Sides (W/E)
5/5
::_::_::_
6/7
::_::
Rear (S)
15
__.__.__.
43
-____-
Other
Height
25
13
City Of Edmonds
Building Department
Work ADDITION AND REMODEL
Address 630 ALDER STREET
Owner MURRAY
-------------
Approved Date. 8/19/2020
Building Official -�/ Luau
Permit Number
BLD2020-0581
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
ENGINEERING DIVISION
APPROVED AS NOTED
��``At 09/01 /2020
It
�T
5utlR,00m
�a
.-4
3 � L dtt
W
I of
r�F
sUmR .0oM
lw
i
I� list
' C; Ott
L
t
f
W
0
o
x l�'C I I1G1 rlD0 z-- Y4'y!'-otvtnt(.^
�! GAP- Ala F., : :� &A.
SUMoo K: 1(00. r RESUB
Aug 04 2020 Air ft.
CITY
OSE
RVICES
OND DEVELOPMENT CES
�61 DEPARTMENT
WSEC 2015 WASHINGTON STATE ENERGY CODE -
WSEC 2015 WASHINGTON STATE ENERGY CODE
WSEC : additions less than 500 sq ft = .5 credit.
PRESCRIPTIVE : MARINE ZONE 4
PRESCRIPTIVE : MARINE ZONE 4
WINDOWS: U.30 FLOOR: R-30 CEILINGS: R-49
Energy option 5a : Efficient water heating
WINDOWS: U.30 FLOOR: R-30 CEILINGS: R-49
SKYLIGHTS: U.50 SLAB FLOOR: R-10
SKYLIGHTS: U.50 SLAB FLOOR: R-10
JU
Showerheads: 1.75 GPM
BELOW GRADE WALL: R-10/15/21 INT
BELOW GRADE WALL: R-10115/21 INT
WOOD FRAMED WALL: R-21 HEADERS: R-10
Faucets: 1.0 GPM
WOOD FRAMED WALL: R-21 HEADERS: R-10
V
EXPOSED EXISTING FRAMING: 2x4 WALLS = R-15
EXPOSED EXISTING FRAMING: 2x4 WALLS = R-15
All other lavatory faucets: 1.0 GPM or less.
R101.4,3 2x6 WALLS = R-21
R101.4.3 2x6 WALLS = R-21
FOUNDATION VENTING 1 : 150
AREA OF FOUNDATION: 440 SO FT
EGRESS WINDOWS: R310.1 - 301.6
R102.7.1 _ ADDITIONS, ALTERATIONS REPAIRS- �—
VENT AREA REQUIRED: ItSO
5.7 SQ FT CLEAR OPENING
ADDITIONS, ALTERATIONS or REPAIRS TO ANY STRUCTURE
INN.
Q-5 VE45
44 IN. FLOOR -TO -TOP -OF -SILL: MAX
SHALL CONFORM TO THE REQ FOR A NEW STRUCTURE WITHOUT
VENT OPENING Win 36 INCHES of
NET HEIGHT CLEAR : 24 IN.
REQUIRING THE EXISTING STRUCTURE TO COMPLY WITH ALL THE
EACH CORNER, IF POSSIBLE.
NET WIDTH CLEAR : 20 IN,
REQ OF CODE.
CRAWL SPACE ACCESS:
REQ IN ALL SLEEPING ROOMS,
EXISTING WALLS EXPOSED DURING CONSTRUCTION MAY -
16" x 24 " CLEAR THRU FOUND WALL
HABITABLE ATTICS, BASEMENTS
REMAIN 2'X 4 WITH R-15.
18" x 24" CLEAR THRU FIN. FLOOR
IThe isolated footing is for a
I NO SPECIAL KEYS, LOCKS, ETC
O
A
4
' Yf. WALL
future project. Please WINDOWS OPENING TO GRADE
,document. The isolated footing ,
5.0 SQ FT OK. 310.2.1X
lis for the 2015 IRC code cycle. I
so'- o"
L-------------
-Oh 10-rill Z; 1)
SHEAR WALL 1:
5W-1
��`�
• 7/16" PLYWOOD /OSB 5/8" OR T1-11
r- y ---� 8d @ 6" EDGES
vk
"'( ��`�. • 8d @ 12" FIELD
W .i•>;
-� ('/" x 10" ANCHOR BOLTS @ 35" ox.
X IQj . w/in 12" of SILL ENDS, SPLICES !�
• w/ 3" x 3" x '/" SO WASHERS /
a'l ` �� I' <<o a� �c�"o.c.• r W� c�� 6A WAY
,� q 2 r LGt'�• SIMPSON BP/LBP
1 0�. Ix, l0Hrt a) IIIo•G• 6
l 0ii 4 X 4 Pf F05T + • EMBED 7.5 "min.
f2`�
I 4x10 Df2
0
1705, A00 iL f -
tZ�t1DV� PA110 U OW
�- to - o N�,w L'IVIW
I I
ACC -")FOUNDATION JOINS:
DRILL & EPDXY #4 DOWELS. -TO LAP
with NEW FOOTING REINFORCEMENTS.
USE SIMPSON SET-XP w/ 4 in EMBED.
I ,
1-W ICAO.
l X .9 �5 _
I
I I ,
-
f
� � I
i 41 EMI f. CCZAVJL.
I I I Cx•C�QiZ�E
�z - -- - �i-
— i — — — —I T
---::
- r.r+... . err. ter. ter• .r. � w—• .n... w► ...r. i -r.► � I
L:_b�J
(2) Icy" x l�" x 29Post' (2)-4 fA•W ,
/M .,/ I.C-r5 4X-4 PT
�ou�l�aTio�J F I Ahf %�=ro
N
iL
L
N
TUB & SHOWER: 2015 /RC — —
• PROVIDE SMOOTH NON-ABSORBANT SURFACES
TO 72 IN ABOVE FINISHED FLOOR
• SHOWER ENCLOSURE & ANY GLAZED SURFACES
w/ LOWER EDGE Win 60 IN
/ (MEASURE VERT/HORZ FROM ANY SHOWER/TUB EDGE)
• TO BE TEMPERED/SAFETY/SHATTERPROOF GLASS
SHOWER DOOR HAVE 24 IN CLEARANCE, OPEN
OUT REQ (CAN ALSO OPEN IN)
• SHOWER FLOW MAX 1.75 GPM or LESS
TOILET: 1.6 GAL MAX
LAV / KITCHEN FAUCET: MAX 1.0 GPM OR LESS \
Vf
1
J
SMOKE DETECTORS: IRC 31\4
INSTALL IF BLDG PERMIT REQ'D
• IN EACH SLEEPING ROOM
• OUTSIDE SLEEPING ROOMS
• ON EACH FLOOR
ALARM DEVISES -INTERCONNECTED
Range 15 ft. per, unit.
CARBON MONOXIDE ALARMS: !RC 315.1 / RCW 19,27.530
• REQ'D OUTSIDE SLEEPING AREAS IN HOMES
• WITH FUEL -FIRED APPLIANCES and/or ATTACHED GARAGES.
• REQ INSIDE BEDROOMS w/ GAS FUELED APPLIANCES
• ALARMS ON EACH FLOOR.
• MUST BE HARD -WIRED/ PLUG-N STYLE (not battery)
• MUST INSTALL IF BUILDING PERMIT REQ'D.
• COMBO w/ SMOKE ALARMS OK.
ALL SMOKE DETECTORS IN RESIDENCt
TO BE INTERCONNECTED FOR PERMH
TO BE FINALLU.
i
t o', 0 0
2� 2�
(61 040
-
--- 5W I
-T
1P
E
1'20�f
BATH.• OPERATE INTERMITENTLY :
50 CFM or
CONTINUOUSLY: 20 CFM
LAUNDRY: SAME AS BATH
KITCHEN.- OPERATE: 100 CFM or
(5) AIR CHANGES PER HOUR.
KITCHEN EXHAUST FANS
OVER 400 CFM REQUIRE MAKE-UP AIR.
ALTHOUGH NOT REQUIRED IT IS
HIGHLY RECOMMENDED TO INSTALL
SMOKE & CARBON MONOXIDE ALARMS
IN THE GARAGE AREA
HARD WIRED or PLUG-IN
NOT BATTERY OPERATED.
`t �-
1✓X. C0 K3C ,
_ r_ x, FA_ TI o
t �r3'
-
'� Swt - W l
14 a.► d�. .�. r EX .rJd`� ^► w� �....+.+ �...... ,.... •....r. r ..-. w.�
X . (a° to B
I
V L l C
.....;,- ----•: LAY I
u
20
r (- 4 N '1 lad• 1 `7 U P U ICI Ii' 12-
a
N �ii d E✓x /
I �0yfiy
4 X4 Pf.
Zo yr� I
T.
THE CONTRACTOR SHALL VERIFY
ALL DIlVIENSIONS AND CONDITIONS
IN THE FIELD PRIOR TO CON71?UC77ON.
ALL DISCREPANCIES SHALL BE
REPORTED TO THE DESIGNER -
DO NOT SCALE DRAWLVGS.
LJ Au,/2
l lllml ,
- �K15TtfrJ(a
WAY
3
rRo�oS�.�
y
N
ad �, �L�. � l !� o'
C161 fr_-x1st lz�F_s
15(04 ex, . ATT Q AC_A6uE—
17Z 7 sQ. FT. Npuj Totem.
t �o0 5q •PT f' !''LOVED 5UNkeem)
RESUB
Aug 04 2020
•: CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
49/z,0z_o
Z �l v 0L.9-
Wl
8d•� � y
64ILAD LI
ti t 1-oGI �D !/1'r0.(-.
COMP V_00�
�0 I%VLT
IZ
cT)x
Q1764 L. J
a
P�Ir- ILArs D "CtzXIAe Za-
IDA
VENI D D L4,6q
�AG/GI N
T
I-
1
2 41 x ,�
x
Y "
D13L 10P FL
ZX IP "21 by �D I t/
(:A)
2 lQ �17 pL 50L11P tbLV,'G
Wi (2) lea Ian"
VgV_ t�A v_R_-[ 2 xt)
IL
Rip a L ,- r/ '` '7UL,4V I'�L�C� (yt �ZJ�A'(�
- 'fD F JD. UTALL,
Lt�ZID I < < / ?CIb Rt
065/cvx -
wl
2�, ko rl, y I _ Wl .
/ W/ 5x)'') ,,A" 50,WAShIiC
( Sim? 0PS113F)
W(KI IZ° of 5lLL ENn-2
t
1 D9_ V IV�VJ
A°
7'
rm
J � Dtl
Iry 7
I „ M/ crb 44 z..w
4
�/,Ob0 5 I Z'e
_—
P�f2t Dl2AlIJ W� �'(L,'�Vi� �A('72tL (2�, � 00�T
5�1ZIZD��p w1 Lb"kqJTfi�o�2Z-
9 IZ-AI Q ca ZAV OL_ •
. .5��A2n�f� rtZ�M K�oO>% 'D�ItS� �SPLA�NI�LoCk��
Tina WUL
c0K0 1�0_f Au, E)(ttit
FRAM 04(d 10 kI w
CaIIIZDI51L 'C2U9ti Pt:iz.
THE CONTRACTOR SHALL VERIFY
ALL DIMENSIONS AND CONDITIONS
IN THE FIELD PRIOR TO CONTRUCTION.
ALL DISCREPANCIES SHALL BE
REPORTED TO THE DESIGNER
DO NOT SCALE DRAWINGS.
1L�:L l �__W
,Oil
U I U N fill, veI4v I:::, / —
ROOF -OVER FRAMING
HEM -FIR 92 @ 24 " O.C.
SPAN SIZE
0' — 6' 2x4
6' — 9' 2x6
9' —12' 2x8
9�*
R-oPo5ED PLOOF FLAB
/A
FIELD VERIFY
TRUSS PITCH & DIMENSION
BEFORE ORDERING!
ROOF VENTILATION :1: 300
AREA OF ROOF: �l&Z • SQ FT
VENT AREA REQUIRED: 154. SQ IN
DISTRIBUTION OF VENTS:
50% IN UPPER PORTION: t0 0 • SQ IN
50% IN LOWER PORTION: SOON
ROOF JACKS: • 2 50-60 SQ IN EACH
RIDGE VENTS: °E --1p' 18 SQ IN / LIN FT`
CON'T SOFFITS: --p 9 SQ IN / LIN FT
GABLE VENTS: 75% OF VENT AREA
RES . , ,
Aug 04 2020
CITY OF EDMONDS I�%� Zllty
DEVELOPMENT SERVICES
DEPARTMENT
Ex• wAu_IC7
_tL
PATv M W AIEZ MFTt�P--
A. too
. t
F-K 13 loin
c lol `
lol• D :k log • tb i'
403 •= q = tob •7� , v --
e� • a- Z z,. M,�x
J� : "V-5
F.,
H E I GH`( CA LO-5,
F"?0115-0 RIZAV-- le7okioM -Y-+ it -
New
— " .sk .w 11A 1I
A
_____--__---.-------____._.___..__
_J
r
-------- --- ---- - -
( aNZA& � K-ru-iF->J___----
•
I� ZO F o '� r-,b tl -T- W E--2'f
1t3.ti• E>L
NNW
�I MEQ OAY
" At CJIJD ��K• KDDF
-oM --- - -- --- --- — — - —
.eEtO.O�
l RESUB
�OF 013 FED EA-5-f L�� , , "I Aug 02020
�� E CITY OF DMONDS
DEVELOPMENT SERVICES
DEPARTMENT.
i
i
1
C.
tow
N1
CC
r.
r■
FN
❑■
n
0
Nothing in this permit approval process shall be interpreted as allowing or
permitting the maintenance of any currently existing illegal, nonconforming,
or unpermitted building, structure, or site condition which is outside the
scope of the permit application, regardless of whether such building,
structure. or condition iq chnwn nn the Q1tP nlan r�i nr n'
.. .. r. TV 1114r.
structure, or condition may be the subject of a separate enforcement action.
Sound/noise originating from temporary construction sites as a result of
construction activity are exempt from the noise limits only during the hours
Of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays,
excluding Sundays and Federal Holidays. At all other times the noise
originating from construction sites/activities must comply with the noise
limits, unless a variance has been granted. ECC Chapter 5.30
All changes in plans and field modifications shall be approved by the local
jurisdiction.' The design professional shall prepare drawings as required for
approval. IBC 107.4
Temporary address shall be clearly visible from street during all phases of
construction. Failure to properly post house/building numbers may result in
no inspection by the City Inspector. Curb signage is not acceptable.
Address numbers (4" min. ht. & 1/2" min. stroke width) shall be posted to be
plainly visible from the street or road fronting the property. IRC R319
LIFE SAFETY NOTES
Smoke alarms shall be installed in each sleeping room, outside of each
separate sleeping area in the immediate vicinity of the bedrooms, and on
each level (including basements and habitable attics) in new construction
and in existing dwellings when alterations, repairs or additions requiring a
permit occur. Smoke alarms shall be hard -wired with battery backup, and
when more than one smoke alarm is required within an individual dwelling
unit, they shall be interconnected. Discuss exceptions to the power source
requirements with the Building Inspector. IRC R314 IBC 907.2.11.2
Carbon monoxide alarms shall be installed outside of each separate sleeping
area in the immediate vicinity of the bedrooms and on each level in new
construction and in existing dwellings when alterations, repairs or additions
requiring a permit occur, or when one or more sleeping rooms are added or
created. IRC R315
Handrails and guards must be capable of resisting a concentrated load of 200
pounds per square foot applied in any direction at any point along the top.
Guard in -fill components must be capable of resisting 50 pounds per square
Pot. IRC Table R301.5 IBC 1607.8
Handrails shall be continuous through stair flights of four or more risers,
without interruption by newel posts (unless at a turn) or other obstructions,
and return to a wall, newel post, or safety terminal. The grip -size shall be
Type I or II or of equivalent graspablity. IRC 311.7.8
Provide one operable escape window in the basement, habitable attic, and in
each sleeping room meeting all of the following requirements:
*An operable area of not less than 5.7 sq. ft. (5 ft' for grade floor opening)
•A minimum clear opening height of 24 inches
•A minimum clear opening width of 20 inches
*No more than 44 in. between finished floor and bottom of the clear opening
*Escape windows located under decks or porches must have a path 36 inches
in height to a yard or court. R310
The greatest riser height within any flight of stairs or the greatest tread depth
within any flight of stairs shall not exceed the smallest by more than 3/8
inch. IRC R311.7.5.1 IRC R311.7.5.2 IBC 1009.7.4
FOOTINGS/FOUNDATIONS
Footing drains are required around concrete/masonry foundations that retain
earth and enclose habitable or usable spaces located below grade, or for
crawl spaces when a minimum 6 inch slope within the first 10 feet of the
foundation wall is not achieved. A separate footing drain inspection by the
Building Inspector is required. IRC R401.3 IRC R405.1
Slab -on -grade floors shall be a minimum 3.54nch thick concrete over a 6
mil vapor barrier and 4-inch base of sand/gravel/etc. There shall be a
thermal -break for slabs inside a foundation wall, and if the slab is less than
24" below the exterior grade, 24" wide R-10 perimeter insulation must be
provided. Slabs used as part of a hydronic heating system shall have R-10
insulation provided throughout the entire slab area.
IRC R506 WSEC R402.2.9 WSEC Table R402.1.1
Vertical rebar must be hooked and tied in place at time of footing inspection.
Maintain minimum 3" clearance to earth, 1-1/2" to form -work for
reinforcement. R403.1.3
Anchor bolts shall be at least %2 -inch in diameter and extend 7 inches into
concrete. There shall be a minimum of two bolts per plate, with one bolt
within 12 inches but not closer than seven bolt diameters from the end of the
plate. The bolt spacing shall not exceed 6 feet o.c. and shall have a nut and
3"x3"x0.229" washers unless engineered. IRC R403.1.6
�i�tllrlll�l l� v �� MECHANICAL NOTES (continued)
Hardware and fasteners in contact with preservative -treated wood shall be of Provide the combustion air required for the proper operation of the
❑ hot -dipped zinc galvanized steel, stainless steel, silicon bronze or copper. appliance(s). The minimum required volume per the standard method is 5
IRC R317.3.1 IBC 2304.12 cubic feet per 1000 BTU/hr. Where exhaust fans, clothes dryers, and
Joists less than 18" and beams less than 12" to grade and all wood exnosed kitchen ventilation systems interfere with the onerntinn of nnnlintines
J
U to weather shall be preservative -treated or naturZlly resistant to decay. u makeup air shall be provided. Fuel -fired appliances shall not be located it
IRC R317 IBC 2304.12 sleeping rooms, bathrooms, toilet rooms, or storage closets unless specific
J
u
u
J
Joists shall have not less than 1.5 inches bearing on wood or metal and 3
inches on concrete. Joists shall be prevented from rotating at the ends and at
intermediate support by approved hangers, 2 inch nominal blocking, or
attachment to a rim board. IRC 502.6/502.7
Foundation cripple walls shall be framed of studs not less in size than the
studs above. Walls over 4 feet in height shall be framed of studs having the
size required for an additional story. Cripple walls studs less than 14 inches
in height shall be sheathed on at least one side with a wood structural panel
that is fastened to both the top and bottom plates in accordance with Table
R602.3 (1), or cripple walls shall be constructed of solid blocking. Cripple
walls shall be supported on continuous foundations. IRC R602.9
Prior to the framing inspection, the building must be dried in with a
minimum of roofing, windows, and siding paper installed.
(Truss layouts showing girder truss/hip-master locations are not permitted to
change and must be followed correctly. If the truss manufacturer requests to
change, in part or in whole, the layout shown, they must contact the
architect/designer to ensure that the structural design of the building is
maintained. If the layout shown is changed, in part or in whole, the Building
Division requires new engineering calculations and must approve the
changes prior to the installation of the roof sheathing.
Exterior and bearing wall studs may be notched <25% and bored <40% of
the stud width. Non -bearing wall studs may be notched <40% and bored
<60% of the stud width. Any bore located <5/8" from the stud face is
considered a notch. Rafters and joists may be notched in the outer thirds of
the span with a maximum notch depth 1 /6th and a notch width 1 /3 rd the
depth of the member. Rafters and joists may be bored up to 1/3rd the depth
of the member no closer than 2" to each edge or to another bore. Top plates
notched or bored >50% of the width must have a 16ga. strap, 6 inches past
and fastened with 8-10d nails at each side of the opening.
IRC R502.8 IRC R602.6 IBC 2308
Attic access openings are required for buildings with combustible ceiling or
roof construction over an area >30 sq. ft. and with a 30" vertical space
between ceiling and roof framing members. The rough -framed opening
shall be 22"x30" and located in a hallway or other readily accessible
location. The access cover shall be weather-stripped and insulated to a level
equal to the surrounding surfaces. IRC R807.1 WSEC 402.2.4
Attic ventilation openings shall not be less than 1/150 of the area of the
space ventilated. It may be reduced to 1/300 if at least 50 percent and not
more than 80 percent of the required openings are at least 3 feet above the
eave vents with the balance provided by the eave vents. The net free
cross -ventilation area may also be reduced to 1/300 when a Class I or II
vapor barrier is installed on warm -in -winter side of the ceiling. IRC R806.2
Access shall be provided for all under -floor spaces. Openings through the
floor shall be a minimum of 18"x24". The access cover shall be
weather-stripped and insulated to a level equal to the surrounding surfaces.
Openings through a perimeter wall shall be a minimum of 16"x24".
IRC R408.4 WSEC R402.2.4
Crawl space ventilation openings shall not be less than 1/300 of the area of
the space ventilated. Required openings shall be evenly spaced to provide
cross ventilation. One side may have no openings. The use of wood or
metal louvers can reduce the net free area to below that required - see
G2407.10. IRC R408.2
MECHANICAL NOTES
❑ Provide outdoor air inlets in all habitable spaces.IRC 1507.3.4.4
i
A 30"x30" level working space shall be provided in front of the control side
to service appliances. In attics and underfloor areas, a passageway a
minimum of 30 inches high and 20 inches wide traveling not more than 20
feet from the access shall be provided. A 24 inch wide solid pathway shall
be provided in attics. A switch -controlled luminaire is required at the
passageway opening and a receptacle outlet at or near the appliance. A
means of electrical disconnect is required within sight of the appliance or the
breaker is to be capable of being locked in the open position.
IRC M1305 IMC 306 NEC 422.31(B)
An exhaust hood/system of >400cfm installed or required by the range or
cooktop manufacturer must be provided with makeup air equal to the
exhaust air rate. IRC M1503.4 IMC 505.2
installation requirements are met. IRC G2406.2 G2407.4 G2407.5.1
IFGC 303.3 304.4 304.5
FIRE -RATED CONSTRUCTION
Dwelling/garage separation shall be maintained by installing 1/2" gypsum
wallboard on the garage side from the foundation to the underside of the
roof sheathing. Ceiling of garages with habitable space above shall have
5/8-inch Type X gypsum wallboard attached with 1-7/8 inch 6d coated nails
❑ or equivalent drywall screws and the structural elements supporting the
pp g
ceiling protected with i/2 gypsum wallboard. Enclosed accessible space
under stairs shall have walls, under -stair surface and any soffits protected on
the enclosed side with 1/2" gypsum wallboard. Water resistant gypsum shall
Provide required makeup air in the laundry room. Louvered doors or not be used as a the backing board where there will be direct exposure to
❑openings/grilles into other spaces may be used to meet the requirements. water, or in areas subject to continuous high humidity (showers, etc.).
Other limitations may arise if a gas dryer is installed. IMC 504.5
IRC R302 IRC R702.3.8.1
G2407.4 G2407.9.1
Dryer ducts shall terminate outside of the building, 3 ft. from any openings
into the building. The termination shall have a backdraft damper and no
screen. The dryer duct shall be a minimum .016-in. (27 ga.) thick, a
minimum 4 inches in diameter, have a smooth interior finish, have sections
joined with the insert end in the direction of airflow without the use of
❑ fasteners, be supported at 4 ft. intervals, and secured in place and protected
by nail plates that extend 2" above/below bottom/top plates. The joints shall
be sealed with UL 181 A listed mastic or tape. Dryer duct maximum lengths
are 25 ft. for electric and 35 ft. for gas with deductions for fittings (or ❑
sized/length per manufacturer). If concealed, the equivalent length of the,
duct ;shall be permanently labeled or tagged within 6 ft. of the dryer
connection. IRC M1502 M1601.4.1 G2439 IMC 504 IFGC 614
PLUMBING NOTES
UN:
r.
IFE
NUN
Fixtures installed on a floor level that is lower than the next upstream
manhole cover of the public or private sewer shall be protected from
i backflow of sewage by installing an approved type of backwater valve.
Fixtures on floor levels above such elevation shall not discharge through the
backwater valve. UPC 710.1
Vent all plumbing fixtures through the roof per UPC 906.0 or with a loop
vent per UPC 909.0. Air admittance valves are not permitted unless first
approved by the Building Inspector on a case by case basis.
Water heaters installed in attics, attic -ceiling assemblies, floor -ceiling
assemblies or a floor/sub-floor assembly, where damage may occur from a
leak; shall be installed in a watertight pan made of corrosion -resistant
materials. The pan shall have a minimum 3/4" drain and the drain'shall
terminate in a visible location. The drain cannot empty into the crawlspace
beneath a building. Discharge from a relief valve into a water heater pan
shall; be prohibited. UPC 507.4 UPC 507.5
Access will be required for the whirlpool/jetted tub pump and the tempering
valve for all tubs. The tempering valve may also be installed at the water
heat' r. UPC 409
Soaker and jetted tubs shall be installed and supported per the
manufacturer's installation specifications. UPC 409.6
Showers shall be a minimum of 900 square inches and be capable of
encompassing a 30 inch circle. The shower receptor shall have a finished
dam; curb, or threshold between 2" and 9" above the top of the drain. The
floor of the shower shall slope a minimum of 1/4" and a maximum of %2".
Lini g materials for built-up showers and shower seats shall be sloped,
extend upward 3" above the horizontal surface, and over the top of the dam
or t eshold. Shower receptors shall be tested by filling with water to the
top of the rough threshold while plugged at the drain. Protect the weep
hole,$ in the sub -drain clamping ring from clogging. UPC 408.5 - 408.7
Mai building shut-off required on water supply line. UPC 606.2
Hot ater heater must be seismically anchored or strapped at points within
the u per one-third and lower one-third of its vertical dimensions. At the
lowei point, a minimum distance of 4" must be maintained above the
controls with the strapping. UPC 507.2
Vent hot water tank relief valve directly to the outside. UPC 608.5
All pressure absorbing devices (e.g. air chambers, mech. devices, hammer
arrestors) shall be accessible or installed per manufacturer. UPC 609.10
Pressure reduction valve on main water supply line required by City code.
Hose bibs (exterior faucets) are required to have a permanently affixed
anti -siphon device installed. UPC 603.5.7
Hyd onic heating system piping shall be tested at 100 psi water pressure or
1 %im ' 2 es the operating pressure, whichever is greater, for a minimum of 15
min&s. Piping embedded in concrete shall be pressure tested prior to the
placi4g of concrete and be maintained at operating pressure during concrete
placement. The test must be observed by the Building Inspector prior to
concrete placement. Note: a means of providing outdoor air per IRC
R303.4, M1507 and IMC 403.2 is required. IMC 1208 -1209
Refrigerant circuit access ports located outdoors shall be fitted with
locking -type tamper- resistant caps. IRC M1411.6 IMC 1101.10
UK
FEA
O
Fire sprinkler systems shall be extended, altered, or augmented as necessary
to maintain and continue protection whenever the building is altered,
remodeled, or added to. IFC 901.4
Fireblocking shall be provided to cut off all concealed draft openings (both
vertical and horizontal) and to form an effective fire barrier between stories,
and between a top story and the roof space. Fireblocking shall be provided
in wood -frame construction in the following locations:
1) In concealed spaces of stud walls and partitions, including furred spaces
and parallel rows of studs or staggered studs as follows:
1.1 Vertically at the ceiling and floor levels.
1.2 Horizontally at intervals not exceeding 10 feet.
2) At all interconnections between concealed vertical and horizontal spaces
such as occur at soffits, drop ceilings and cove ceilings.
3) In concealed spaces between stair stringers at top and bottom of the run.
4) At openings around vent, pipes, and ducts at ceiling and floor level, with
an approved material to resist the free passage of flame and products of
combustion. ' For additional requirements see IRC 302.11
Draftstops shall be installed in combustible construction where there is
usable space both above and below the concealed space of a floor/ceiling
assembly, so that the area of the concealed space does not exceed 1000 sq.
ft. and shall divide the space into approximately equal areas. Where the
assembly is enclosed by a floor membrane above and a ceiling membrane
below, draftstopping shall be provided in floor/ceiling assemblies under the
following circumstances:
1.Ceiling is suspended under the floor framing.
2.Floor framing is constructed of truss -type open -web or perforated
members.
Draftstopping materials shall not be less than 1/2 inch gypsum board, 3/8 inch
wood structural panels or other approved materials adequately supported and
installed parallel to the floor framing members. IRC R302.12
ADDITIONAL REQUIREMENTS
Height verification shall be done by the applicant's agent/contractor and
observed by the Building Inspector on site. The agent/contractor shall set up
the equipment (transit/builders level), establish the datum point, and the
point of average grade. These items must be consistent with the approved
plans. If the proposed height of a building (as shown on the plans) is within
12 inches of the maximum height permitted for the zone, an elevation survey
is required. An elevation survey consists of three components to be
conducted by a licensed surveyor. 1) Prior to construction, the surveyor
shall, establish average grade as specified in ECDC 21.40.030, and shall
establish a reference datum point that -will be undisturbed and can be freely
accessed. 2) The surveyor shall locate the elevation of the first floor prior to
the City under -floor inspection. 3) A final letter of height confirmation shall
be provided upon completion of the structure.
A survey may be required prior to the foundation wall inspection if the
Building Inspector is unable to verify setbacks. Lot line stakes should be in
place at the time of the foundation inspection and established property pins
should be made visible.
RESUB
Aug 04 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
o
N
Z
06
CNN
�
4
�n
o
;
Q
U
C)rA
o
'rA
Q
♦'
';>
W
�
'~
Q"
w
�
aA
o
,
UAL
. C. J !S
CN
1�
�I
I
NAILING SCHEDULE
NAILS SHALL NOT BE DRIVEN CLOSER TOGETHER THAN Yz THEIR
LENGTH NOR CLOSER TO THE EDGE OF MEMBER THAN X THEIR
LENGTH. NAILING NOT NOTED BELOW OR ON PLANS SHALL BE A
MINIMUM OF 2 NAILS AT EACH CONTACT:
8d FOR 1 x MATERIAL and 16d FOR 2x MATERIAL.
JOIST / RAFTER AT ALL BEARING —TOE 1 3 —10d
JOIST / RAFTER TO SIDES of STUD ;
2 x 8 MEMBER OR SHALLOWER 3 -16d
FOR EACH ADDITIONAL FOUR (4)
INCHES OF DEPTH 1-16d
DOUBLE JOISTS, RAFTERS, HEADERS 2 —16 d @ 12 "o.c.
BLOCKING BETWEEN JOISTS/RAFTERS:
TO JOIST/RAFTERS TOE NAIL EA SIDE,EA END 2 -10d
TO JOIST/RAFTERS BEARINGS TOE NAIL, EA SIDE , " 2 —10d
BLOCKING BETWEEN STUDS, TOE NAILS, EACH END 2 —10d
BUILD-UP CORNER STUDS 16d @ 12" o.c.
2- SUBFLOOR TO JOIST/GIRDER, BLIND / FACE NAIL 16d @ 16" o.c.
TOP PLATE / SOLE PLAE TO STUD, END NAIL 2 —16d @ 2 x 4
3-16d@2x6
TOE NAIL 4-8d
DOUBLED STUDS, FACE NAIL 16d @ 12" o.c.
DOUBLED TOP PLATES, FACE NAIL 2 -16d @ 16" o.c.
TOP PLATES, LAPS (4'-0- MIN) FACE NAIL 12 -16d
TOP PLATES, INTERSECTIONS, FACE NAIL 2-16d
CONTINUOUS HEADER TO STUD, TOE NAIL 4 — 8d
CEILING JOISTS- LAPS OVER PARTITIONS, FACE NAIL ---16d
CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL 3 -16d
CEILING JOIST LEDGER -FACE NAIL TO STUDS
2x4 and 2x6 2-16d
2x8 andupto2x12 3-16d
y LEDGER TO STUDS
2 x 8 MEMBER or SHALLOWER 3-16d
FOR EACH ADDITIONAL 2 " 1-16d.
SMOKE DETECTORS IRC 314
ALL NEW CONSTUCTION / REMODELS REQUIRING A PERMIT
MUST INSTALL APPROVED UNITS.
LOCATIONS: IN EACH SLEEPING ROOM
OUTSIDE SLEEPING AREAS (HALL)
ON EACH FLOOR —INCLUDING HABITABLE
ATTICS/ BASEMENTS.
GARAGE OPTIONAL, BUT RECOMMENDED.
RANGE OF UNITS: ABOUT 15 FT.
ALARM DEVISES INTERCONNECTED SO ALL ACTIVATED TOGETHER
NEW CONSTRUCTION REQ. WIRED TOGETHER.
REMODELS, ALTERATIONS, ADDITIONS: CAN BE BATTERY
OPERATED.
CARBON MONOXIDE ALARMS IRC 315.1 / RCW 19.27.530
I
REQUIRED OUTSIDE SLEEPING AREAS IN HOMES WITH FUEL -FIRED
APPLIANCES or ATTACHED GARAGES. ON ALL FLOORS.
REQUIRED IN BEDROOMS WITH GAS FIRED APPLIANCES, LIKE
FIREPLACE
MUST BE HARD-WIRED/PLUG-IN NOT BATTERY.
COMBO WITH SMOKE ALARMS: OK
i
PERMIT = INSTALLATION
EXCEPTION: IF OWNER OCCUPIED BEFORE 7/26/2009.
MUST INSTALL BEFORE SALE OF HOME.
K-2.4
IZ• 15
E-10
'
DESIGN CRITERIA
------------
GENERAL CONSTRUCTION NOTES:
E
Q
TRUSS NOTES
WOOD CONSTRUCTION
-
;" ;
• -
N
RI
STUD: 2x4, 2x6, 3x4, 3x6 HEM -FIR
_
CONSTRUCTION TYPE:
VB
-
ALL WORK MUST COMPLY WITH ALL -CURRENTLY ACCEPTED CODES.
: " 00
�
• STRESS ANALYSIS/DRAWINGS/DETAILS SHALL BE STAMPED BY AN
SILL PLATE: 2x4, 2x6, 3x4, 3x6 HEM -FIR
OCCUPANCY:
R 3
2015 INTERNATIONAL BUILDING CODE (IBC)
°n
O
APRROVED STATE OF WASHINGTON REGISTERED ENGINEER.
POST/COLUMN 4 x DOUG FIR #1
SEISMIC DESIGN
D 1
2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
• PRE -MANUFACTURED TRUSSES SHALL BE IDENTIFIED BY
POST/COLUMN 6 x DOUG-FIR #1
WIND SPEED
85/110 MPH
and ALL OTHER APPLICABLE MECHANICAL/SAFETY CODES.
Z
,woo
MANUFACTURERS STAMP
JOISTS 2 x 8 to 2 x 12 HEM -FIR #2
EXPOSURE
B / C •
2
• USE APPROVED / APPLICABLE RUSS SUPPORT HANGERS
BEAMS/HEADERS 4 x6 to 4 x 12 HEM -FIR #1
SNOW LOAD
25 PSF
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO
p
. .
• ALL ROOF TRUSSES SHALL BE SO FRAMED AND INTO THE
FROST LINE DEPTH
18 INCHES
THE REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS AND
o
c
FRAMEWRK SO AS TO FORM AN NTEGRAL PART OF THE WHOLE
GLU-LAM BEAMS (GLB): top fiber bott fiber stress Fc
WINTER TEMP
17 degrees
NOTES.
w
.c
BUILDING. ROOF TRUSSES SHALL HAVE JOINTS WELL -FITTED AND
24F-V4 1200psi 2400 psi
ICE BARRIER REQ
No
2. DIMENSIONS ARE TO FACE -OF -FRAMING. DO NOT SCALE
z
-:
SHALL HAVE ALL TENSION MEMBERS WELL TIGHTENED BEFORE
24 F-V8 2400 psi 2400 psi
ANNUAL MEAN TEMP
49 degrees
DRAWINGS. FIELD VERIFY BEFORE CONSTRUCTION or
tA
C4.
ANY LOAD IS PLACED UPON THE TRUSS. DIAGONAL/ SWAY
PARALLAMS (PSL) 2900psi 2900 psi 2900 psi,
ASSUMED BEARING
ORDERING SPECIFIC MATERIALS.
0
f
BRACING SHALL BE USED.
SOIL
2000 PSF
3. VERIFY EXISTING CONDITIONS, GRADES AND DIMENSIONS AT
• ENGINEERING DATE /DETAILS SHALL BE APPROVED BY THE
��
ROOF SHEATHING: 15/32 DOC PS-1/PS-2 APA RATED
(AT NEW FOUNDATIONS)
r,
THE SITE. LOCATON OF BUILDING ON PROPERTY LIES WITH
Q
N
i,n
BUILDING OFFICIAL BEFORE ANY FIELD CUT OR TRUSS
32/16 SPAN RATING w/ EXPOSURE 1 GLUE.
THE OWNER/CONTRACTOR. BUILDING PERIMETER AND FLOOR
Ln
� ;
ALTERATION.
SUB -FLOOR SHEATHING: % " DOC PS-1/PS-2 APA RATED
GRAVITY LOADS
ELEVATIONS SHALL BE ESTABLISHED. BUILDING SET BACKS
• FIELD IDENTIFICATION OF LIGHT METAL PLATE -CONNECTED
STURD-I-FLOOR 24 IN O.C.
AND HEIGHT RESTRICTIONS COMPLIANCE SHALL BE VERIFIED
TRUSSES IS REQUIRED. INFORMATION BRANDED, MARKED OR
WITH EXP 1 GLUE.
ROOF DEAD LOAD 15 psf
BY CONTRACTOR.
OTHERWISE PERMANENTLY AFFIXED TO EACH TRUSS SHALL
WALL STURCURAL PANELS: SEE ENGINEERING FOR THICKNESS.
ROOF LIVE LOAD 25 psf
4. LICENSED SURVEYOR SHALL VERIFY EXCAVATIONS/HEIGHTS IF'.
CONTAIN THE FOLLOWING:
FLOOR DEAD LOAD 15 psf
REQUIRED/NEEDED.
IDENTIFICATION OF TRUSS COMPANY
• USE QUALITY WOOD MEMBERS WITH NO SPLITS, KNOTS -
-FLOOR LIVE LOAD 40 psf
-
-. - 5. COMPETENT EXPERIENCED MECHANICAL ENGINEER, LICENSED
_ THE DESIGN LOAD
• METAL CLIPS, ETC TO BE SIMPSON STRONG TIE. NAILING PER
BALCONY LIVE LOAD 60 psf
CONTRACTOR OR PLUMBER SHALL DESIGN THE PLUMBING,
W
THE TRUSS SPACING.
MANFACTURER.
PARTITION LOADS 10 psf
HEATING, VENTILATION, SPRINKLER AND AIR CONDITIONING
-
• SEE ENGINEERING NOTES FOR BOLTS.
SYSTEMS. PERMITS FOR ALL WORK BEFORE BEGINNING.
-- -, -
i
RETE SHALL BE PRESSURE
6. FURNACE & VWATERHEATERS: INSTALL PER WSEC IRC OR
,
.
WSEC 2015
WASHINGTON STAVE` ENERGY CODE
MARINE ZONE 4:
WINDOWS (VERICAL) U.30 MIN
SKYLIGHTS U. 50
CEILING R 49 (R 38 w/ RAISED HEEL/
Or STICK FRAMED)
WOOD FRAME WALL R 21
FLOOR 0 R •� 8
BELOW GRADE WALL 10/15/21 int +TB
SLAB ON GRADE R 10
R 10 CONTINUOUS UNDER HEATED SLAB.
R 10 CONTINUOUS AROUND EXTERIOR 24 IN
ATTIC DUCTS R 8
R-10 CONTNUOUS INSULATION ON EXTERIOR OF WALL or R-15
CONTINUOUS INSULATION ON THE INTERIOR OF WALL or R-21 CAVITY
INSULATION PLUS THERMAL BREAK BETWEEN SLAB and BASEMENT WAL
AT THE INTERIOR OF BASEMENT WALL.
• 10/15/21/+ TB :
R 10 CONT. INSUL ON THE EXTERIOR OF WALL
or R 15 ON THE CONTINUSOUS INSULATION OF THE INTERIOR OF WA
or R 21 CAVITY INSULATION +THERMAL BREAK BETWEEN SLAB -
BASEMENT WALL AT INTERIOR OF BASEMENT WALL
or R13 CAVITY INSULATION ON INTERIOR OF BASEMENT WALLS PLUS
R 5 CONTINUOUS INSULATION ON INTERIOR/EXTERIOR OF WALL
R 13 MEANS: R 10 CONT INSUL ON THE INTER/EXTER OF HOME
or R 13 CAVITY INSUL AT THE INTER. OF BASEMENT WALL.
• 10 / 13 MEANS R-10 CONTINUOUS INSULATION ON THE
INTERIOR/EXTERIOR OF THE HOME or R 13 INSULATION AT THE INTERIOR
OF THE BASEMENT WALL.
• TB MEANS THERMAL BREAK BETWEEN FLOOR SLAB /BASEMENT WALL.
BELOW GRADE INSULATION OPTIONS
WSEC 2015 R 402.2.8
r r
DRlPE 4jm_jTyr
EVu. ..
14AT IZS,
IZ 1 D'
• ALL WOOD IN CONTACT WITH CONC LOCAL CODES, WHEN GAS APPLIANCES LOCATED IN GARAGES
TREATED, PER AWPA STANDARDS FOR WESTERN SPECIES. BOLTS, - - ALL PILOTS, BURNERS, SWITCHES LOCATED A MIN, of 18 '
NUTS & SCREWS USED IN EXTERIOR APPLICATIONS/PRESSURE
TRETED MATERIAL SHALL BE HOT -DIPPED GALANlZED (ASTM 2015 IBC INCHES ABOVE FINISHED FLOOR. PROVIDE SYSTEM FOR7P
' A153)OR STAINLESS STEEL. HOLD DOWN DIVICES COATED WITH 2O15 IRC ADEQUATE COMBUSTION AIR. SUCH APPLIANCES IN GARAGES
TO BE PROTECTED FROM DAMAGE WITH BOLLARDS/BARRItRS.
CORROSION PROTECTON PER ASTM A123. 2012 IMC '
2012 IFC FIRE CODE 7. DUCT ALL FANS, VENTS, DRYER, RANGE HOODS TO OUT-5IDE.
:.CONCRETE 2016 WSEC INSULATE IN UN -HEATED SPACES. CHAP. 17
COMPRESSION IN 28 DAYS SACK MIX : 2011 NAT ELEC CODE 8• KITCHEN VENT FANS OVER 399 CFM TO BE PROVIDED WITH
MAKE-UP AIR AT APPROX. THE SAME EXHAUST AIR RATE. `
SLAB -ON -GRADE 3000 PSI WA STATE AMENDMENTS M 1503.4
(INTERIOR) 9. WHERE REQ ROOF/FOOTING DRAINS SHALL BE TIGHT -LINED
SEPARATELY TO APPROVED DISPOSAL. STORM DRAINAGE
SLAB -ON -GRADE 3000 PSI 5 Y CONTROL SHALL MEET THE REQ. OF THE ENGINEERING DEPT
(EXTERIOR) STANDARD PLAN FOR THE JURISDICTION GOVERNING THE
CONSTRUCTION SITE.
BASEMENT WALL 2500 5 Y
LL
10. PROVIDE FURRINGS, AS REQ TO CONCEAL MECHANICAL/
-
ELECTRICAL WORK IN ALL FINISHED AREAS. OBSERVE CODES
FOOTINGS 2500 5 %
FOR FIRE BLOCKING, INSULATION FOR SITE.
CONT, FOOTINGS 2500 5 Y
11. VERIFY TYPE, MANUFACTURER AND LOCATION OF ALL
PLUMBING FIXTURES, FAUCETS, DOORS, WINDOWS, CABINETS.,
REBAR:
HARDWARE, LIGHT
12. ING FIXTURES & APPLICANCES WITH OWNER PRIOR TO
#4 OR LESS GRADE A&O Y
PURCHASE / INSTALLATION.
;
#5 OR GREATER GRADE 60
13. IN SEATTLE PROVIDE DEAD BOLT CATCH/ APPROVED
LOCKING DEVICE PER SEATTLE BUILD. CODE.
'
14. OBSERVATION VISITS TO THE SITE BY DESIGNER/
DEFINITIONS
REPRESENTATIVES SHALL NOT BE CONSTRUED AS INSPECTION
- NOR APPROVAL OF CONSTRUCTION. -
15. ALL WORKERS ON -SITE SHALL BE KNOWN TO CONRACOR
FOOTING: FOUNDATIONAL SUPPORT, USUALLY MASONRY.
-
AND THEIR SAFETY A FIRST PRIORITY.
LIVE LOADS: LOADS PRODUCED BY USE/OCCUPANCY OF
STRUCTURE.
16. WHEN IN DOUBT ... ASK! ! !
DEAD LOADS: WEIGHT OF ALL MATERIALS OF CONSTRUCTION
INCORPORATED, INCLUDING FLOORS, ROOF, WALLS
--
ETC. NOT FURNITURE.
;
ROOF LIVE LOADS: DURING MAINTENTANCE THE LOAD PRODUCED
BY WORKERS, EQUIPMENT, MATERIALS.
FRAMING• SKELETON OF BUILDING INTERIOR & £XT
. - ERIOR WALLS,
FLOORS, ROOFS.
PLATE: HORIZONTAL FRAMING MEMBER AT TOP/BOTTOM OF
WALL STUDS.
STUD: VERTICAL MEMBER OF FRAME -WALL, AT ENDS AND
EVERY 16 OR 24 INCHES ON CENTER.
JOIST: ONE OF A SERIES OF PARALLEL FRAMING MEMBERS
THAT SUPPORT A FLOOR OR CEILING. -
IBLE USE
' WHENEVER PO
AMERICAN MADE
RODUCTS
IN YOUR CONSTRUCTI
N PROJECT.
KEEP OUR FELLOW
ENS WORKING.'/•
UST OF AMERICAN MA
UFACTURERS
AVAILABLE ON R
UESI:
RESU B
CALL
BEFORE YOUDIG: DIAL 811
~ www.calgiifiW&6�dig.com
OF EDMONDSo '
dig.com
lZI &