Loading...
APPROVED BLD-BLD2023-0029+Architectural_Plan+1.9.2023_6.38.25_AM+330351622014830 REGISTERED ARCH ITECT ELIZABETH LAY STATE OF WAS ILA I Im;z Ft IF= S I El IF= I C IF= NGTON KITCHEN REMODEL J 8714 TALBOT RD EDMONDS WA 98026�5049 J 7 7 0 L z(7) oO w Q m ,^ � v wo � w o � ~ w WHERE ADDITIONS OR ALTERATIONS REQUIRE A I o = v)LIJ PERMIT TO BE ISSUED INTERCONNECTED SMOKE zz � w w SEPARATE PLUMBING PERMIT ALARM AND CO DETECTORS THROUGHOUT THE I 2E � > DWELLING ARE REQUIRED. REFER TO 2018 IRC a uJ z o 1 REQUIRED FOR THIS PROJECT. 1 ' R314 AND R315 FOR MORE INFORMATION. I c; w o LU 2 w iD D-CD CD iD r CDCD ALL WORK SUBJECT V OBTAIN ELECTRICAL =o APPROVED �u- TO FIELD PERMIT FROM _ 0 PLANS MUST BE _� INSPECTION FOR STATE LABOR & ON JOB SITE cli CD o CODE COMPLIANCE INDUSTRIES 0c) F-w U to w w �ECEIVED _ ■ ' - 0 0 Jan 10 2023 n s to I I per manufacturers City Of Edmonds DE VECITY OPOF EDMONDS MENT SERVICES 1 � U DEPARTMENT Building Department � 0 specifications. Have all 1 ; Work INTERIOR REMODEL =) � manufacturer Address 8714 TALBOT RD LLI = o 1 • documentation on site. ; Owner LANTZ ZN 1 • ..............................................� Approved Date 02/02/2023 a o Z / 0¢ Building Official: �e(�%ft �OOfft /�(44 C t 0 Permit Number' BLD2023-0029 -------------------------------------- 0 O U � Q Z D_ 0 O � U w 0 ~0 PROJECT INFORMATION: GENERAL CONSTRUCTION NOTES m= SITE INTERIOR WORK ONLY - NO GROUND DISTURBANCE PROPOSED. OWNER: GENERAL CONSTRUCTION NOTES: of a_ LANTZ BRETT & KATHY 1. GENERAL: 0 0 A. ALL DIMENSIONS ARE TO BE FIELD VERIFIED. a � ADDRESS: 8714 TALBOT RD , EDMONDS, WA 98026-5049 B. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, CMU OR OTHER STRUCTURE UNLESS NOTED OTHERWISE. PROJECT SCOPE: C. IN WOOD CONSTRUCTION PROVIDE SOLID 2x BLOCKING BEHIND ALL WALL MOUNTED KITCHEN REMODEL - NO PROPOSED EXTERIOR WORK. ACCESSORIES AND FIXTURES. D. ALL CASEWORK TO BE DESIGNED BY CASEWORK MANUFACTURER. PARCEL: 00594400005502 E. CASEWORK MANUFACTURER/INSTALLER SHALL TAKE ON -SITE MEASUREMENTS PRIOR TO FABRICATION TO INSURE PROPER SIZE AND ACCURACY. LEGAL DESCRIPTION: 2. SITE CONSTRUCTION: TALBOT PARK BLK 000 D-02 - PTN TR 55 BEG AT MOST WLY COR A. SALVAGE, RECYCLE, REUSE MATERIALS DURING CONSTRUCTION IN ORDER TO SD TR THS 40*54E ALG SD S WLY LN THOF 140FT TH N 49*06E AT REDUCE WASTE. R/A 100.03FT TH N 39*38 48W PLT NELY LN SD TR 119.39 FT TAP ON B. DISPOSE OF ALL REMAINING WASTE MATERIALS INCLUDING TRASH, DEBRIS AND WLY LN TH S60*27 30W ALG SDWLY LN 104.68FT TPB EXC NWLY EXCESS TOPSOIL OFF OF THE OWNERS PROPERTY UNLESS DIRECTED OTHERWISE 5FT TO CITY OF EDMONDS C. WATER WILL BE PROVIDED BY CONNECTION TO EXISTING WATER LINE.. 3. WALL BOARD: ZONE: RS-20 A. ALL INTERIOR WALL AND CEILING FACES ARE TO BE SHEATHED WITH 1/2" (WALL) AND 5/8" (CLG.) GYPSUM BOARD EXCEPT WHERE NOTED TO USE 5/8" TYPE "X" GYPSUM BOARD (OR CODE: NOTED OTHERWISE). SCREW ALL GYPSUM BOARD TO WALL STUDS, PLATES, BLOCKING, ETC. WITH BUGLE HEAD DRY WALL SCREWS AT 7"o.c. TAPE, TEXTURE, AND PAINT GYPSUM BOARD ACCORDING TO FINISH SCHEDULE. USE "DUROCK" OR APPROVED EQUAL CEMENT BACKER BASED ON THE 2018 I.R.C., 2018 UPC, 2018 WA BOARD AT ALL WALLS TO RECEIVE TILE FINISH. STATE ENERGY CODE, AND 2018 WA STATE 4. FINISH NOTES: AMENDMENTS A. USE FIBERGLASS REINFORCED MESH JOINT TAPE AT ALL GYPSUM WALL BOARD OCCUPANCY GROUP R-3 CONSTRUCTION TYPE VB ALLOWABLE FLOOR AREA UNLIMITED FLOOR AREA (SF) TOTAL RENOVATED AREA >500 SF SHEET INDEX: JOINTS. B. ALL INTERIOR WALL AND CEILINGS SHALL RECEIVE SMOOTH PLASTER FINISH UNLESS NOTED OTHERWISE. ALL OTHER WALLS SHALL BE PAINTED WITH FLAT LATEX ENAMEL. VERIFY WITH OWNER. C. ALL INTERIOR FINISH MATERIAL SELECTIONS SHALL BE MADE BY OWNER. D. ALL APPLIANCES TO BE SUPPLIED BY OWNER. A0.1 TITLE SHEET A1.1 SITE PLAN A2.1 DEMO PLAN A2.2 FLOOR PLAN A3.1 ELEVATIONS A3.2 INTERIOR ELEVATIONS A4.1 SECTIONS A9.1 DETAILS 40 PDS Map Portal Snohomish County Planning 6 Development Services Map Title 7/27/2022 ' 8723 r• Legend Snohomish County Tax Parcels t •,�. i i ' 8712 x ass •��}..�: a • � �'' � f 8716 a 1: 600 t 75 t t nn 0 100.0 50.00 100.0 Feet 4u inapt m,.. Intl .,crm.,on ., a h h-hh rw.1. I. ro� .rrtmne wow., tlny Intl a. na o b. coniw.tl an pnhm cs,on a a egesenp,on d, Me Snahomhn County Catle. AmerMmen,s aM uptlaes a Ne We. egelhc wtn aher appscab! County c— paHlmni Notes m appys chat had, herein-Sndumish Caunry mesas no repiasena,on awargmy<oncernag meconcsrt accuracy,currency, d the L1a <onantl hemw IM e. tlhc�anta d inert Nnt,bil a Ihnesi tar an wnR°" wrwa M picn, xce„In9 a dherM. uun9 ,hh [n assume all m,pons,Mb br us ,hemd Intl a9ae a hob Snanomhh [aunt' This map was automatically generated using Projection: NAD_1983_StatePlane_Washington North FIPS_4601 Feet Geocortex Essentials. Planning and Development Services, Snohomish County YVashig, 50. II.c Ch. 4M K , pmhaaa, rtata aM local agency, hom pn✓dM zgss p Ns d iMV 1, inb 1e, br use 6w canmeic.lpuim ark,thu=wcomm 1usmaybm.a.dIirywawmp has dM,d,,hcrnolns]nwn. o0� = J LU U_r Q CU OU U w 11� = U LJJ Q Cn Q Z W _0 <� 0 0 Z LU _0 Cl) wz w ; �Q IN 0 I— -0 z `o Q J 00 z 0 E w z w U z o `� IEEEEEEE CO W w � Q J C)� co 0 00 N co J CNJ N co z 0 W CD N N C) U0 w E2.1 ELECTRICAL PLAN N ME�� °' Q g SOLID WALL DBL. 2x FRAMING SOLID WALL DBL. 2x FRAMING SHEATHING @ WINDOW SHEATHING @ WINDOW NEW SIDING O/HOUSE (SEE JAMB. (SEE JAMB. 22014830 REGISTERED WINDOW STRUCT.) CORNER BEAD STRUCT.) CORNER BEAD ARCHITECT HEADER WRAP TO MATCH EXIST. SHIM AS REQ'D. SHIM AS REQ'D. (SEE STRUCT.) 1/2" GYP. BD. 1/2" GYP. BD. Ar SOLID WALL R-10 RIGID SHEATHING ELIZABETH LAY INSUL., TYP. (SEE STRUCT.) SILL SILL STATE OF WAS INI BELOW BELOW BUTYL RUBBER FLASHING 2x DF STUD 2x DF STUD 1/2" GYP. BD. W/ SELF-ADHESIVE WALL W/ BATT WALL W/ BATT BACKING. APPLY OVER INSULATION. INSULATION. INFILTRATION BARRIER AS SHOWN. SEALANT AS REQ'D. 26 GA. GALV. HEAD FLASHING CORNER SHIM AS NECESSARY BEAD � DUAL GLAZED NEW SIDING O/HOUSE NEW SIDING O/HOUSE VINYL WRAP WRAP J WINDOW SYSTEM DUAL GLAZED DUAL GLAZED BUTYL RUBBER BUTYL RUBBER VINYL VINYL C:) FLASHING w nnnIA/ ¢YSTEM FLASHING WINDOW SYSTEM 6' No W/ SELF-ADHESIVE SEALANT W/ W/ SELF-ADHESIVE 700 BACKING. APPLY OVER BACKER BACKING. APPLY OVER SEALANT W/ � Z < w Q INFILTRATION BARRIER ROD INFILTRATION BARRIER BACKER � V AS SHOWN. AS SHOWN. ROD w o I� H w WIND W HEADER DETAIL WINDOWJAMB DETAIL WIND W ILL DETAIL o� w w z� 1 3" = 1'-OII 2 31' = 1'-0II 3" = 1'-01, 0 LLj Q 0 Q H z o U w 00 G7W (.o Lu � W t�D 1p �ILLI U C)C) 0 0 EXTERIOR DOOR THRESHOLD EXTERIOR Q N N DOOR 26 GAUGE GALVANIZED O BONDERIZED THRESHOLD SUBFLOOR NEW OR EXIST. u_ PAN FLASHING SHEATHING TJI'S OR 2X 0o 2x4 STUD WALL @ 16" O.C. p CAULK BETWEEN Y PER JOIST OR o 0 FLASHING STRUCT. RAFTER, TYP.Lu GYPSUM BOARD = 3: AND COMPRESS TOGETHER 2x4 FLAT @ 4'-0" NAILING AS REQUIRED o 0 O.0 C z 2x DECKING PER 2x4 BOTTOM PLATE z STRUCT. EEO Op 2x DECK JOISTS PER v STRUCT. � = ECEIVED SLOPE @ 1/4" PER FOOT TO DRAIN. 5/8" GYP. BD. CEIL., � ~ 3/4" SUB FLOOR o o Jan 10 2023 SELF-ADHESIVE FLASHING TYP. z z FLASHING FLOOR JOISTS " o CITY OF EDMONDS oa- PER STRUCT. 11 7/8 TJ I/25 s U DEVELOPMENTDEPARTMENT RVICES RIM JOIST SEE PLAN FOR o 0 R-38 INSUL. WALL TYPE O SHEATHING PER STRUCT. Q � PT MUD SILL, TYP. CONC. FDN. PER STRUCT. w o �w = cn Q w RESHOLDODECKWALL-FL. PARALIEL - Q13� 4'no 1 " = 1'-0" 5 1 " = 1'-0" 6 1 1/2" = 1'-0" z OQ P:z U =) LLI O F- O rn 0- LL �\ =0 0 Q \ - HEAD FLAP FOLDED DUPONTT" TYVEIOTAPE _O OVER HEAD FLASHING. O p OPTIONAL BACKDAM DETAIL PEEL LARGEST STRIP OF HEAD FLAP FOLDED U U 0 0 0 WHEN USING 9'WIDE RELEASE PAPER FIRST. UPWARD TO EXPOSE O W ft - HEAD DUPONT FLExWRAPT'NF 0 0 SHEATHING. 0 F_ 0 0 FLASHING �R"���F em u"ft ® EXPOSED C) 0 C O SHEATHING. W � H 0 0 0 0 .0 0 \ DUPONTT' TYVEK° TAPE DOAA = 0 Q 0 0 0 NO GAPS IN 0 0 pZ cn CORNERS Q 0 / 0 / Y C) 0 0 0 O Cl �. Nw� \ -_ 0 If SILL _ W - - - \ 0 0 Q 0 0 0 0 — — — N N. OU 7 " Uw L 0 0 0 ® ° f LL1 t=W o o o cn Q STEP 17 STEP 16 STEP 15 - STEP 14 STEP 8 o STEP 7 0 STEP 6 0 STEP 5 z Q _0 �z 0 N 0 A. INSTALL THE SILL FLASHING. REMOVE THE A. PREPARE THE SILL FLASHING BY CUTTING A A. FLIP THE CUT HEAD FLAP UPWARD TO 0 A. TAPEALL CUTS IN DUPONT TYVEeWRB AND TAPE A. TRIM THE A. FLIP DOWN UPPER FLAP OF A. FOLD SIDE FLAPS INTO ROUGH < � V J A. INSTALL DUPONTT" RESIDENTIAL SEALANT OR ACROSS HEAD OF THE WINDOW WITH DUPONTT" TYVEK® WRB 1"-2" ABOVE THE DUPONTT TYVEK®WRB SO IT LAYS FLAT LARGEST STRIP OF RELEASE PAPER, ALIGN PIECE OF DUPONTT^ FLEXWRAPT NF THAT IS EXPOSE THE SHEATHING AND OPENING AND SECURE TO INSIDE p O W E RECOMMENDED SEALANT (AND BACKER ROD AS DUPONT(TM) TYVEK(R) TAPE, 4" DUPONTT FLASHING WINDOW OPENING. ACROSS THE HEAD FLASHING. THE FLASHING WITH THE INTERIOR EDGE OF AT LEAST 12" LONGER THAN THE SILL LENGTH. TEMPORARILY SECURE WITH WALL. SECURETO INSIDEWALL WITH LLI z NECESSARY) AROUND THE WINDOW OPENING AT THE TAPE OR DUPONTTI STRAIGHTFLASHT1 B. WHEN TRIMMING THE SILL AND INSTALL INTO ROUGH OPENING B. USE 6" DUPONTT'" FLEXWRAPT" NF DUPONTT' TYVEK°TAPE. TYVEK® TAPE OR cn Y W DUPONTT- TYVEK�WRB, DO NOT CUT OR ACROSS SILL AND UP JAMBS (6"MIN.). FOR 2"x 4' FRAMING DUPONTT" TYVEK®WRAP CAP W p INTERIOR. IT IS ALSO ACCEPTABLE TO USE = z _0 DUPONT' WINDOW AND DOOR FOAM OR RECOMMENDED DAMAGE THE HEAD FLASHING THAT HAS B. APPLY WORKING FROM THE MIDDLE OF THE AND 9" DUPONTTN FLEXWRAPT' NF FASTENERS F- Q FOAM AT THE INTERIOR CAVITY OF THE JAMBS AND HEAD. BEEN INSTALLED BEHIND IT. SILL TOWARDS THE SIDES. SECURE FOR 2"x 6" FRAMING. IF FOAM IS USED AT THE SILL, RECOMMENDED SEALANT DUPONTT" FLEXWRAPTm NF TIGHTLY INTO C. INSPECT INSTALLATION SURFACE TO ENSURE N O THE CORNERS BY FIRST WORKING IN ALONG THE SURFACE IS FREE OF DIRT AND SHOULD BE USED AT THE SILL AREA BEHIND THE FOAM THE SILL BEFORE ADHERING UP THE JAMBS. SUBSTANCES THAT COULD INTERFERE WITH -0 TO ENSURE A PROPER WATER SEAL. C. DO NOT STRETCH MATERIAL ALONG THE SILL ADHESION AS WELL AS ANY SHARP (6 OR JAMBS. PROTRUSIONS. CORRECT DUFwT- FwsRNaTAPE wFRI SHEATHING INSTALLED I� DUFwT-FLEXv -rr OVER BARE STUDS J 00 0 0 0 0 0 DUPONTT. TYVEK®WRB SHEATHING FASTENERS BARE STUDS 0 I ® 0 0 ® 0 0 0® DUPONT- TYVEK® WRAP CAP FASTENERS OUTLINE OF ROUGH 0 ROUGH OPENING OPENING TO BE CUT INCORRECT �� WINDOW TO BE 0 0 0 EXTERIOR DUFwT- FLA1HNNaTAPEFwsR wTrR OUTLINE INSTALLED ° FOR WINDOW. 0 0 0 0 0 0 0 / 0 / 0 0 0 0 0 0 0 / ouF"cN1mF wRP-NFR E0.E I 0 0 i I DIRECTION AI Z / f � DUPONTT"^TYVEK°WRB �° POSITIVE DRAINAGE 0 0 0 FLOW. INTERIOR L 0 i 0 0 i 0 0 0 ° \ / J D ° ° TN STEP 13 STEP 12\ r4% STEP 11 � STEP 10 � STEP 9 � � � � � J 3:o STEP 4 0 STEP 3 0 STEP 2 STEP 1 Z p U) A. CUT A PIECE OF 0 A. CUT TWO PIECES OF 0 A. INSTALL WINDOW ACCORDING TO 0 A. 0 A. REMOVE NARROW PIECE OFTHE RELEASE 0 O DUPONTT' STRAIGHTFLASHTN, DUPONTT" FLASHING DUPONTTm FLASHING TAPE OR MANUFACTURER'S INSTALLATION APPLY (CONTINUOUSLY) DUPONTT" RESIDENTI PAPER. A. CUT AN'I-CUT' (STANDARD I -CUT) IN 0 A. DUPONTTm TYVEK® WRB TO BE 0 A. SHEATHING TO BE INSTALLED OVER BARE BARE STUDS PRIOR TO SHEATHING INSTALLATION. DUPONTT" STRAIGHTFLASHTN FOR JAMB INSTRUCTIONS. SEALANT OR RECOMMENDED SEALANT ON B. FAN DUPONTT" FLEXWRAPT' NFAT BOTTOM THE DUPONTT. TYVEK® WRB. MECHANICALLY FASTENED AND INSTALLED STUDS. W W TAPE FOR HEAD FLASHING, SLOPE SILL FRAMING TO EXTERIOR. FRAMING AND B. HEAD FLASHINGTO EXTEND BEYOND FLASHING EXTENDING 1"ABOVE WINDOW THE HEAD AND JAMBS OF ROUGH OPENING CORNERS AND ADHERE ONTO EXTERIOR B. CUT A HEAD FLAP AT A 45 ANGLE TO OVER SHEATHING. B. AFTER SHEATHING HAS BEEN INSTALLED, CUT " NON -WATERPROOFING COMPONENTS ARE ONLY OUTER EDGES OF JAMB FLASHING. HEAD FLANGEAND 4" TO 6" BELOW (ON TOP OF WRB). FACE OF WALL, COVERAGE SHOULD BE 2" EXPOSE 8" OF SHEATHING TO ALLOW B. DO NOT INSTALL FASTENERS WITHIN 6" OF AN OPENING IN THE SHEATHING ALONG THE SHOWN SCHEMATICALLY. SEE DRAWINGS BY 0 C. REMOVE RELEASE PAPER AND INSTALL BOTTOM EDGE OF SILL FLASHING. B. IF SEALANT IS APPLIED TOTHE SILL, TO 3" INCHES ONTOTHE FACE OF THE WALL FOR HEAD FLASHING INSTALLATION. THE SILLS AND JAMBS OFTHE OPENINGS PERIMETER OF THE ROUGH OPENING FOR OTHERS FOR DETAILED INFORMATION. COMPLETELY COVERING WINDOW B. REMOVE RELEASE PAPERAND PRESS ENSURE THAT THERE ARE AT LEASTTWO C. PRESS SILL FLASHING W1 FIRM HAND AND WITHIN 9" OF THE HEAD OPENINGS. WINDOW. Q Q MOUNTING FLANGE AND ADHERING TO THE TIGHTLY ALONG SIDES OF WINDOW (2) 2' INCH GAPS IN THE SEALANT BEAD FOR .PRESSURE ORJ-ROLLER TO ENSURE FULL C. ENSURE THE SHEATHING IS CUT FLUSH WITH J LO z EXPOSED SHEATHING. FRAME. EVERY 4' OF WINDOW TO ALLOW FOR ADHESION ON ALL SURFACES. OR SLIGHTLY BELOW THE SILL FRAMING TO 0 Nt O DRAINAGE. ALLOW FOR POSITIVE DRAINAGE. N U co co J CO Z TYPICAL WINDOW FLASHINGo o Lu 8 1 1/2" = 1'-0" � U