APPROVED BLD PLN RESUB 1-BLD2024-0097+Architectural_Plan+2.14.2024_6.49.42_AM+4058333IZ rn 0 N O N r SITE PLAN 1 /8" = 1 '-0" 110' PROPOSED (N) HEAT PUMP CONDENSER \\\ NORTH CURB --\ 3RD AVE N 68' 5-0" SIDE YARD SB I I II \ I II 1= 1= I I PRIMARY ENTRANCE 1— PROPERTY LINE 1'-6" TYP. EAVE I I I I I 113' I I I I I HOME I I I II i I I Y I I w I I I 5'-0" SIDE YARD SB I L ---------- - m CD U-) }� T I I LU °C — IC— 68.07' Zone ' RS-6 Corner N Flag , N Setbacks: Required Actual Front------------ 20' 15'4" 5' 3'9"N Sides ____ 3'6"S ----- 15' -_251An Y Rear 5' shed 6'6" shed ------------ Other ----- 25' exist Height =-----------' ------ PROJECT SUMMARY LEGAL DESCRIPTION: SUNSET ADD TO CITY OF EDMONDS BLK 000 D-00 - LOT 14 PARCEL: 00592200001400 DESCRIPTION: INTERIOR REMODEL OF EXISTING SINGLE FAMILY RESIDENCE JURISDICTION: EDMONDS LOT SIZE: 7,583SF LOT COVERAGE: NO CHANGE TOTAL NEW AND REPLACED IMPREVIOUS AREA: NO CHANGE There is no mechanicall ,permits for a heat j ,pump associated with j ithis permit at time of i .review. Please obtain !separate Mechanical ,permit from the City of j iEdmonds.—•—.—.—•� .There are no Plumbing I !permits associated (with this permit at time i ,of review. Please iobtain a separate .plumbing permit from ! Ithe City of Edmonds. 0 _._._. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED BY PLANNING Feb 15 2024 Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. COVER SHEETS G1.0 COVER SHEET ARCHITECTURAL A1.1 EXISTING FIRST FLOOR PLAN A2.1 PROPOSED FIRST FLOOR PLAN A3.1 SCHEDULES A4.1 DETAILS S2.1 STRUCTURAL PLANS OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department ----------------------------................................. Work INTERIOR REMODEL .................................................................; Address 423 3RD AVE N Owner GZ EDMONDS LLC Approved Date 2/21 /2024 Building Official w. Permit Number BLD2024-0097 .................... VICINITY MAP PROJECT ils - ca Sater Ln ,Z I tT Jcy� y I Aloha Way r I I � I a� ,� I I O -_ I nq I o^� C Iwill ConstructioniQ - Community Temporarily closed Christian Fellowship �•� Q, 0 ? Q I I ,ca 2 I Q Z Edmonds Center Glen St For the Arts o: Jack and; A I Breakwater Conde: Z 19 Holy Coco's Shop & Drop _ = Soul Hair Design Q Daley St Daley St - I I Q303 Beac?i'v%lalk: Loughrin 8 Fdho Com any CPAs I - -- ---- ---- - --- ----- ------------- ------ ----- SITE LOCATION GZ EDMONDS LLC RESIDENCE 423 3RD AVE N EDMONDS, WA 98020 PERMIT SET JAN UARY 13, 2024 SYMBOLS LEGEND LETTERS HORIZONTAL GRID TAG A NUMBERS VERTICAL DOOR TAG AO - DOOR NUMBER WINDOW TAG 16 - WINDOW TYPE REVISION TAG 1\ REVISION NUMBER NORTH ARROWS - PROJECT NORTH PROJECT 1 - ELEVATION NUMBER ELEVATION TAG A101 SHEET NUMBER BUILDING SECTION TAG 1 SIM SECTION NUMBER A101 SHEET NUMBER SIM WALL SECTION TAG 1 - SECTION NUMBER A101 - SHEET NUMBER DETAIL TAG MEMEL-1 SIM DETAIL NUMBER A101 SHEET NUMBER CEILING TAG 10' 0' - CEILING HEIGHT TITLE LINE 01 SUMMARY OF WORK INTERIOR REMODEL OF EXISTING SINGLE FAMILY RESIDENCE VIEW NAME 1 /8" = V-0" \\ DRAWING SCALE DRAWING NUMBER BY SEPARATE PERMIT ELECTRICAL PLUMBING HVAC O N U (D co J JzQ C/) W zap O p z 0�0 LIJ CO N N 0 (Dqd- Lu REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT COVER SHEET DESIGN DATE REVISION 01 /13/24 PROJECT NUMBER SCALE As indicated a ci 04 N O N M F- J D m U) g m a� a :_ 0 0 Y x 0 n 0 L a� U m L Q N 0 0 Y E c 3 O w a) Cl) Al (E) EGRESS WINDOW OEXITING FIRST FLOOR 1/4 11-011 (E) EGRESS WINDOW 23'-2 1 /2" 2 ;� --------------------------------------------------------------------------------------------------------- ( DEMOLISH (E) DOOR. PREPARE AREA FOR (N) INFILL WALL. DEMOLISH (E) WINDOW. PREPARE AREA FOR (N) DOOR. - JJLJI KITCHEN 17-1 T-8" I I 1 u� --�-�- - - - - - - - - - _51/2" ' BATH I I �I 3'-51,� I 1 4'-3 1 /2" LAUNDRY T-8" j MUD I I T-11" LO II C� C 4'-10" O a U- 0 - zz LO �a wW DEMOLISH (E) DOOR. PREPARE AREA FOR (N) WINDOW. N DINING CO In i •J7 _ I� I� IIII I � BATH III L IIII � i r N • -J III��I to II i; �I BEDROOM 13'-51/2" ------ — — — — 2'-5"Ilk .y II W.I.C. II 12'-8" = in DEMOLISH (E) I 10'-3" M I I INTERIOR WALLS u PER PLAN �I I J BEDROOM LIVING i r I N 20'-7" ' I � ROOM " "I I En 1 (E) WALLS, TYP. DEMOLISH (E) WINDOW. PREPARE AREA FOR (N) WINDOW AND (N) INFILL WALL. (E) PRIMARY ENTRANCE CN DEMOLISH (E) WINDOW. PREPARE AREA FOR (N) WINDOW AND (N) INFILL WALL. 19 (E) WINDOW 1 2 (E) WINDOW DEMOLISH (E) DOOR. PREPARE AREA FOR (N) DOOR AND (N) INFILL WALL. OEXISTINGSECOND FLOOR 1/411 = 1 0, HOUSE VENTILATION 2018 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1505, INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FAN PER 1505.4.4 TABLE 1505.4.3(1) & TABLE 1505.4.3(2), PROVIDE CONTROLS PER 1505.4.2. COMPLY WITH WSEC R403.5. SYMBOL LOCATION MINIMUM FAN REQUIREMENTS op A Bath & Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1505.4.4) Powder B Kitchen Min. 100 cfm (INTERMITTENT)@ .025" WG (TABLE M1505.4.4) (Range hood or down draft exhaust fan rated at min. 100 cfm at 0.10" wg may be used for exhaust fan requirement.) op C Laundry Min. 180 cfm (INTERMITTENT) @ .025" WG - to function and be Room labeled as whole house fan (4-5 BEDROOMS 3001 < 4500 SF.) TO OPERATE 50% OF EVERY FOUR HOUR PERIOD DRYER VENT PER (TABLE Ml502.4.5.1) VENTED TO OUTSIDE *ALL FANS TO VENT TO OUTSIDE SYMBOL LEGEND SM SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR 1 WINDOWS A DOORS —=l EXISTING WALLS DEMO WALLS — NEW WALLS EXISTING FOUNDATION WALL — NEW FOUNDATION WALL NEW SLAB ON GRADE FLOOR PLAN NOTES 1. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. 2 PROVIDE SOLID BLOCKING OVER SUPPORTS. 3 PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. 4 WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES, NOT ROUGH OPENING DIMENSIONS. 5 DOOR JAMB 4.5" U.N.O. 6 ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 7 EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. 8 SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" 9 ALL DOORS STANDARD DIMENSION 4 112" FROM HINGE JAMB TO ADJACENT FRAMING UNLESS OTHERWISE NOTED. 0 N 0 zQ LU Q U) oo z 000-0 �O N W REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EXISTING FLOOR PLANS AS-BUILTS DATE REVISION 01 / 13/24 PROJECT NUMBER SCALE 1 /4" = 1'-0" O_ N N O N co LM a� CU ,_ 0 0 Y x 0 0- 0 L a� U L Q N 0 0 Y a� c 3 O a) Cl) 1 A - N CLOSET EGRESS WINDOW 3� 1 V-7 1 /2" BEDROOM EGRESS WINDOW EMERGENCY ESCAPE ROUTE SM CO —7 H 3X5 SHOWER BATH A - � N N � SEE DETAIL o0 UP 8/A4.1 `4 J EMERGENCY ESCAPE ROUTE N 1 V-2 1 /2" BEDROOM s o SM 5'-11 1 /2" CO W.I.C. �o DINING W LAUND D 7' GARAGE OPROPOSED FIRST FLOOR 1/411 11-011 20'-4" MI o 0 0 2 SEE SHEET A3.1 FOR WINDOW AND DOOR SCHEDULES (N) INFILL WALL CONVENTIONAL 7/16" OSB CONTINOUS SHEATHING NAIL PATTERN: 6" O.C. ON TOP AND BOTTOM STUD 12" O.C. AT EACH VERTICAL STUD THAT IS 16" O.C. (N) INFILL WALL CONVENTIONAL VERIFY (E) WINDOW 1 MEETS EGRESS REQUIREMENTS. �C�1 A/'C IC AI/lT SEE SHEET S2.1 FOR STRUCTURAL INFO 7/16" OSB CONTINOUS SHEATHING A NAIL PATTERN: (N) DOOR 6" O.C. ON TOP AND BOTTOM STUD 12" O.C. AT EACH VERTICAL STUD THAT IS 16" O.C. (N) WINDOW T-10" 3'-5" 3'-4" 3X5 SHOWER B 9'-6 1 /2" I KITCHEN co CO ®� A 3'-6" REF O 0 16'-4 1 /2" C4 7'-0" ISLAND SM CO M _ M (N) INTERIOR WALLS PER PLAN o JJ [L LL z z LIVING 19 N < ROOM W 16'-2" 7 W.I.C. SM CO 12'-8" N n 6-5 1/2" BEDROOM r n 2 (N) INFILL WALL CONVENTIONAL 7/16" OSB CONTINOUS SHEATHING NAIL PATTERN: 6" O.C. ON TOP AND BOTTOM STUD 12" O.C. AT EACH VERTICAL STUD THAT IS 16" O.C. OF'KUF'UJtU StUUIVU F-LUUK 1 /411 = 1'-0" EMERGENCY N ESCAPE ROUTE (N) INFILL WALL CONVENTIONAL 7/16" OSB CONTINOUS SHEATHING NAIL PATTERN: (E) PRIMARY ENTRANCE 6" O.C. ON TOP AND BOTTOM STUD 12" O.C. AT EACH VERTICAL STUD THAT IS 16" O.C. INSULATION NOTE: EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION FOUND UNINSULATED, OR WITH DAMAGED INSULATION (DISCOLORED OR DETERIORATED), SHALL BE FILLED WITH R15 INSULATION AT 2X4 FRAMING AND WITH R21 INSULATION AT 2X6 FRAMING. REF. SEC R503.1.1-EXCEPTION 2 THIS NOTE IS ONLY FOR EXISTING CEILING, WALL OR FLOORS. ANY NEW IN -FILL WALL PORTIONS OR NEW FRAMED WALL SECTIONS, OR NEW FLOORS/ROOFS MUST FOLLOW TABLE R402.1.1 INSULATION REQUIREMENTS. NEW 2636 CASEMENT EGRESS WINDOW THERMAL INSULATION: (Prescriptive Option III of the WSEC) Walls (below -grade, exterior): R-10 rigid insulation Walls (below -grade, interior): R-21 batt or rigid insulation Walls (above -grade): R-21 batt or rigid insulation Headers R-10 rigid insulation Ceilings (advanced framing): R-38 batt Ceilings (standard framing): R-49 batt Ceilings (vaulted): Icynene with R value of 3.6 per inch Floors: R-30 batt or rigid insulation Slab: R-10 water-resistant rigid insulation 24" @ Perimeter solid doors U-value of .20 or better Windows & doors with glazing U-value of .30 or better skylights U-value of .50 or better HOUSE VENTILATION 2018 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1505, INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FAN PER 1505.4.4 TABLE 1505.4.3(1) & TABLE 1505.4.3(2), PROVIDE CONTROLS PER 1505.4.2. COMPLY WITH WSEC R403.5. SYMBOL LOCATION MINIMUM FAN REQUIREMENTS A Bath & Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1505.4.4) Powder B Kitchen Min. 100 cfm (INTERMITTENT)@ .025" WG (TABLE M1505.4.4) (Range hood or down draft exhaust fan rated at min. 100 cfm at 0.10" wg may be used for exhaust fan requirement.) C Laundry Min. 180 cfm (INTERMITTENT) @ .025" WG - to function and be Room labeled as whole house fan (4-5 BEDROOMS 3001 < 4500 SF.) TO OPERATE 50% OF EVERY FOUR HOUR PERIOD DRYER VENT PER (TABLE M1502.4.5.1) VENTED TO OUTSIDE *ALL FANS TO VENT TO OUTSIDE SYMBOL LEGEND SM SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR 1 WINDOWS A DOORS EXISTING WALLS DEMO WALLS NEW WALLS EXISTING FOUNDATION WALL I� - NEW FOUNDATION WALL NEW SLAB ON GRADE FLOOR PLAN NOTES 1. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. 2 PROVIDE SOLID BLOCKING OVER SUPPORTS. 3 PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. 4 WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES, NOT ROUGH OPENING DIMENSIONS. 5 DOOR JAMB 4.5" U.N.O. 6 ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 7 EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. 8 SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" 9 ALL DOORS STANDARD DIMENSION 4 112" FROM HINGE JAMB TO ADJACENT FRAMING UNLESS OTHERWISE NOTED. N U M� W J J Z LLI Z Q U) O p �0Z p 0 Lu NNp V "Zi- W REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROPOSED FLOOR PLANS DESIGN DATE REVISION 01 /13/24 PROJECT NUMBER SCALE 1 /4" = 1'-0" rn 0 N O N A WINDOW TYPES WINDOW SCHEDULE NO. QTY WIDTH HEIGHT TYPE NEW/EXISTING NOTES U-V) 1 1 3'-4" 3'-0" SLIDER NEW 0.28 3'-4" 7'-8" 8'-0" 5'-6" 2 1 3-0" 7-8" SLIDER EXISTING EGRESS WINDOW 0.28 3 1 2'-6" 5'-6" SLIDER EXISTING EGRESS WINDOW 0.28 Q o 0 `r' M N Q 4 1 2'-0" 4'-0" SLIDER EXISTING EGRESS WINDOW 0.28 5 1 3-0" 5'-6" SLIDER EXISTING EGRESS WINDOW 0.28 o 6 1 4'-0" 2'-6" FIXED NEW 0.28 OP CP ih CP 7 1 3-3" 1'-91, FIXED NEW 0.28 1 7'-8" ao 0 T 5 EMERGENCY EGRESS K 4'-011 N CV _1 0 EXTERIOR DOOR TYPES 5'-6" 3 EMERGENCY EGRESS 7 3'-011 A B 4 EMERGENCY EGRESS AS NEEDED TO OPENABLE EQUAL E AREA 5.7 SQUARE 5.7 SQ. FT. FEET MINIMUM (5.0 for exception above) OPENABLE AREA 5.7 SO. FT. MINIMUM 20" NET I AS NEEDED TO I CLEAR EQUAL 5.7 SQUARE FEET OPENABLE (5.0 for exception above) WIDTH SILL HEIGHT 44" MAXIMUM TO CLEAR OPENING FLOOR 24" CLEAR MIN. EMERGENCY EGRESS REQUIREMENT IN NEW BEDROOMS WHERE EGRESS WINDOWS ARE NOT ADEQUATE, REPLACE WINDOW WITH EGRESS WINDOW WINDOW SCHEDULE NOTES 1. THIS WINDOW SCHEDULE IS FOR REFERENCE ONLY. GC TO VERIFY ALL OPENINGS, DOOR SIZES AND WINDOW SIZES AND QUANTITIES IN FIELD PRIOR TO ORDERING. EXTERIOR DOOR SCHEDULE NO. QTY WIDTH HEIGHT TYPE U-VALUE A 1 5'-6" 6'-8" GLASS SLIDER DOORS 0.28 B 1 3'-0" 6'-8" SWING DOOR W/GLASS 0.28 EXTERIOR DOOR SCHEDULE NOTES 1. THIS DOOR SCHEDULE IS FOR REFERENCE ONLY. GC TO VERIFY ALL OPENINGS, DOOR SIZES, SWING DIRECTIONS AND QUANTITIES IN FIELD PRIOR TO ORDERING. C) N U � Co m J �z< vJ W zap O p 20z 0CC0 wC� N N 0 C� t w REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEDULES DESIGN DATE REVISION 01 /13/24 PROJECT NUMBER SCALE As indicated U a N 0 0 Y i m 0 co D A a FASTEN ONLY @ JAMBS VERT. 1/2" MIN. 24 GA. GALV. SHEET METAL W/ ALL OPEN SEAMS TO BE SOLDERED FIG. WSP-1 TYPICAL WINDOW SILL PAN ISOMETRIC CDC APPROVED BACKER ROD & SEALANT 1/16" INTERMITTENT SHIM TO PROMOTE DRAINAGE. ATTACH TO LOWER NAIL FLANGE 2X TRIM PER ARCH. W/ CANTED TOP EDGE TO DRAIN & SAWED KERF @ BOTTOM & NOTCH TO RECEIVE SIDING 24 GA. GALV. METAL SILL PAN. SEE DETAIL WSP-1 ABOVE 1/2" PT FURRING STRIPS @ 16" O.C. VAPROSHIELD PENETRATION WRAP SIDING VAPROSHIELD BLACK WALSHIELD WRB WINDOW SILL FLASHING DETAIL 6" = 1'-0" BLOCKING AS REQ'I VENT OPENING FIXTURE PENETRATION SIDING INSULATIONS WOOD FRAMII PER STRUCTI 4X8 HEADER ER NEDGE PAN W kINAGE SIDING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) EXTERIOR SHEATHING PER STRUCTURE PLANS INSULATIONS AS REQ. WOOD FRAMING PER STRUCTURE PLAN; WINDOW SILL SIDING 3" = 1'-0" SIDING NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALATION WINDOW FRAME FLASH WINDOW PER MANUFACTURER RECOMMENDATION (IF TRIM IS PROTRUDING BEYOND WINDOW SILL IT MUST BE FLASHED.) HARDIE TRIM BOARD LEAVE APPROPRIATE GAP AND CAULK SIDING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) EXTERIOR SHEATHING PER STRUCTURE PLANS (METAL HEAD FLASHING BY OTHERS) SLOPE 15 z DEGREES C° z_ T G T G OPTIO SEAL W/VAP EXPAN VAPRC EXPAN-i- "r NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD. MEMBRANE AND FLASHING COMPONENTS ARE NOT SHOWN TO SCALE FOR CLARITY. WINDOW & DOOR HEADER FLASHING DETAIL 3" = 1'-0" 1/4" GAP MIN., DO NOT CAULK INTERIOR SHEATHING FLASHING TAPE Z - FLASHING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) TRIM AROUND OPENING WOOD FRAMING \ EXTERIOR SHEATHING ^Y DOOR/WINDOW WOOD RAINSCREEN FURRING AROUND FIXTURE LEAVE APPROPRIATE GAP AND CAULK SIDING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) EXTERIOR SHEATHING PER STRUCTURE PLANS S.A.F. MEMBRANE 1/4" GAP MIN., DO NOT CAULK Z - FLASHING HARDIE TRIM BOARD INSTALL BUG SCREEN AS NECESSARY WINDOW FRAME NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALATION WINDOW/ DOOR HEAD @a SIDING 3" = 1'-0" Q INSULATION WHEI TYP. LAP SIDING 1. HEADROOM MIN. b'-8', WIDTH MIN. 3'-O' PER I.RC. SECTION R311 1. 2. TREADS 10' MIN. DEPTH FROM LEADING EDGES OF NOSING TO N051NG AND R15ER5 134' MAX. HEIGHT PER I.R.G. SECTION R311.15. 3. HANDRAIL MIN. 34' TO MAX. 35' ABOVE TREAD N051%. HANDRAIL TYPE 1 CIRCULAR TO HAVE 1 1/4' MIN. TO 2' MAX. CROSS SECTION DIMENSION AND 11/2' MIN. CLEAR FROM WALL, RETURN RAIL ENDS. HANDRAILS SHALL BE STRONG ENOUGH TO RESIST A 200 POUND POINT LOAD IN ANY DIRECTION PER I.R.G. TABLE R3015 C JAMB u WALL STUDS BEYOND DBL JST, BLOCK AS NEEDED SEE PLAN BEE PLAN FOR TTP. RISE E RUN DIMEN51ON5 3/4' PLYWOOD RISER 1 1/8' HARDBOARD TREAD WITH EASED NOSING (3) 2x12 STRINGERS - TYP. (UXOJ, CENTER STRINGER WITH (2) 2x4 STRONG BACK TYP. ATTACH STRINGER5 W/ (1) A-35 EACH. 1/2' G.W.B. AS REQUIRED BEE NOTES BELOW 2x KICKER PLATE ATTACH 6TRIW_%ER5 W/ (1) A-35 EACH. 4. INSTALL FIRE BLOCKING BETWEEN 6TRINGERS AT THE TOP AND BOTTOM OF EACH RUN PER I.RC. SECTION R602b. 5. COVER USABLE SPACE UNDER STAIR WITH 1/2' G.W.B, PER I.R.C. SECTION R302.1. 6. INTERMEDIATE BALUSTERS SHALL BE SPACED W/ LESS THAN 4' BETWEEN BALUSTERS PER IF-C. SECTION R312.2. I. TREAD NOSING TO HAVE A MAX. R41DIU5 OF 9/16 PROJECT A MIN. 3/4' AND A MAX. OF 1 1/4' ON STAIRS W/ SOLID RISERS. BEVELING OF NOSING NOT TO EXCEED 1/2', PER I.RG. SECTION R311533 STAIR SECTION DETAIL LEAVE 4 DOOR / WINDOW JAMB SIDING �ninnn Connninir_ UPTURN METAL END DAM (BEYOND) WALLSHIELD/ WRAPSHIELD INSTALL WRAPSHIELD "U" BIB FLASHING TO NEXT JOINT IN WRAPSHIELD ASSEMBLY LAP 4" OVER METAL HEAD FLASHING AND SEAL WTIH NON -SKINNING BUTYL OR DOUBLE -SIDED VAPROTAPE SEAL BEHIND NAILING FLANGE MIN. 26 GA. PRE -FINISHED METAL HEAD FLASHING NAIL FLANGE WINDOW SET HEAD FLANGE IN A CONTINUOUS BEAD OF NON - SKINNING BUTYL SEALANT SECURE PER WINDOW MANUFACTURER'S INSTALLATION RECOMMENDATIONS WRAP OR EQUIVALENT) C) N U C) co Jz< 0 3: Z U) <p O 2 0 z pCC0 w Co 75 N N p (� 'qt w REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DETAILS DESIGN DATE REVISION 01 /13/24 PROJECT NUMBER SCALE • As indicated VERIFY (E) WINDOW MEETS EGRESS REQUIREMENTS. REPLACE IF NOT. c 2) ro 1 VERIFY (E) WINDOW 2 MEETS EGRESS REQUIREMENTS. REPLACE IF NOT. 0 o CLOSET N EMERGENCY ESCAPE ROUTE 11'-7 1/2" 1 V-2 1/2" N N BEDROOM r BEDROOM SM) EMERGENCY ESCAPE ROUTE sM) �5-11 1/2" CO SM) CO) W.I.C. /3XR SHOWE _V rN 7(0 1/2" A O L0 BATH A (N) DOOR 9' r N Lr) W F UP I I I I I I T-10" / 3'-5" 3'-4" I I I I I I C) O 13'-9" CO �B N KITCHEN iY M �DINING o o 00 3'-6" 1 /2" oe 916'-4 T-0" ISLAND 7'-10" WJ \ �/ LAUNDRY D �C M GARAGE LOW ROOF FRAMING PLAN 1 /4" = 1 '-0" 20'-4" MUD SEE NOTE #4 M ih B1 I NEW 3 1/2"x18" GLB FLUSH BOTTOM r PANTRY N) INTERIOR WALLS PER AN (N) WINDOW \ 3X5 SHOWER 9'-6 1/2" o FASTEN EA. CEILING JOIST TO NEW FLUSH BEAM w/ SIMPSON LUS26 OR LUS26-2 HANGERS AS REQ'D. IF ANY TRIPLE JOISTS OR FLUSH BEAMS EXIST, CONTACT M+K FOR FURTHER EVALUATION. (TYP.) C? N SEE NOTE #4 a 9'-2 1/2" T W.I.C. NEW 5 1/4"x11 7/8" LVL FLUSH BOTTOM PROVIDE SIMPSON CS16 STRAPS \ ACROSS UNDERSIDE F CEILING JOIST SPLICES (13" END LENGTH) @ EXISTING POST FROM ROOF FRAMING EVERY THIRD BAY (TYP.) FASTENED TO NEW BEAM w/ (3)3"x0.131" TOENAILS (TYP.), IF MORE THAN (2) POSTS FROM ABOVE EXIST, CONTACT M+K FORVG co CUT BACK EXISTING CEILING JOISTS AS OOM FURTHER EVALUATION. REQUIRED FOR INSTALLATION OF NEW r FLUSH TOP BEAM (TYP.) 4'-6" T BATH 16'-2" - OA a 7 f,2. (E) PRIMARY ENTRANCE BUILDER/OWNER NO POST FROM ROOF ABOVE TO BEAR ON NEW FLUSH BEAM WITHIN 48" FROM SUPPORT @ EXTERIOR WALL i THIS END OF LVL MAY BE N SLOPE CUT TO 4" MIN. r DEPTH @ INNER EDGE OF EXISTING EXTERIOR WALL & i2 CUT SHALL NOT EXTEND MORE 24" INTO THE SPAN. EXISTING POST FROM ROOF FRAMING FASTENED TO NEW BEAM w/ (3)3"x0.131" TOENAILS (TYP.), IF MORE THAN (1) POST FROM ABOVE EXIST, CONTACT M+K FOR FURTHER EVALUATION. EMERGENCY ESCAPE ROUTE 1 STRUCTURAL NOTES: NOTE #1: ALL EXISTING FRAMING SPECIFIED ON PLAN SHALL BE VERIFIED IN FIELD (V.I.F.) BY THE BUILDER OR NEW FRAMING SHALL BE PROVIDED NOTE #2: FASTEN NEW STUDS TO EXISTING w/ 0.131"x3" NAILS @ 6" O.C. VERTICALLY STAGGERED (TYP. @ NEW FRAMING) NOTE #3: DESIGNED TO BE STRUCTURALLY SOUND UPON COMPLETION OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE TEMPORARY SHORING/ BRACING OF EXISTING ELEMENTS INTENDED TO REMAIN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT M+K IF ACTUAL SITE CONDITIONS VARY FROM WHAT IS DEPICTED ON THE CONSTRUCTION DOCUMENTS. NOTE #4: PROVIDE BLOCKING IN MAIN FLOOR SYSTEM BELOW NEW POST DOWN TO EXISTING DROPPED CRAWL GIRDER. PROVIDE NEW 4x4 P.T. POST FROM EXISTING DROPPED CRAWL GIRDER TO TOP OF NEW 24"x24"x8" PLAIN CONC. PAD FTG. IN CRAWLSPACE. N SYMBOL LEGEND SM) SMOKE DETECTOR CCOO) CARBON MONOXIDE DETECTOR iO WINDOWS ODOORS EXISTING WALLS _ DEMO WALLS — NEW WALLS F— I EXISTING FOUNDATION WALL F NEW FOUNDATION WALL L- NEW SLAB ON GRADE G�,4 OF WAS11, tee- Ao) yd0�, �F �641 8 a ss JONAL FOR REMOVED BEARING ONLY O N U C)M co J V J J z Q W zQ � 0 p 2E p Z p12L0 W co N N p V 'qd- W REVISION DATE REASON FOR ISSUE RESUB Feb 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROPOSED FLOOR PLANS DESIGN DATE REVISION 01 /13/24 PROJECT NUMBER SCALE 1 /4" = 1'-0"