Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB 1 BLD2023-0084+POOL_CERTIFICATION+5.16.2023_1.16.55_PM+3548176
ICC-ES PMG Product Certificate PMG-1619 Effective Date: May 2021 This listing is subject to re-examination in one year. www.icc-es-pmq.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° CSI: DIVISION: 13 00 00—SPECIAL CONSTRUCTION Section: 13 11 13—Below-Grade Swimming Pools Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier's stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier's quality system. Products: Prefabricated One -Piece Swimming Pool Listee: Modpools Limited 5784 Glenmore Road Abbotsford, BC V4X1X7 Canada www.modpools.com Compliance with the following codes: 2021, 2018, 2015, 2012 and 2009 International Building Code° (IBC) 2021, 2018, 2015, 2012 and 2009 International Residential Code° (IRC) 2021, 2018, 2015 International Swimming Pool and Spa Code° (ISPSC) 2020 and 2017 City of Los Angeles Building Code° (LABC) 2020 and 2017 City of Los Angeles Residential Code° (LARC) 2020 and 2017 Florida Building Code° (FBC) 2020 and 2017 Florida Residential Code° (FRC) 2019, 2016, 2013 and 2010 California Building Code° (CMC) 2019, 2016, 2013 and 2010 California Residential Code° (CRC) 2021, 2018, 2015, 2012 and 2009 Uniform Swimming Pool, Spa and Hot Tub Code (USPSHC)* 'Copyrighted publication of the International Association of Plumbing and Mechanical Officials. Compliance with the following standards: ANSI/APSP/ICC 4-2012, Standard for Aboveground / Onground Residential Swimming Pools ANSI/APSP/ICC 5-2011, Standard for Residential Inground Swimming Pools Identification: The prefabricated one-piece swimming pools are identified by the manufacturer's name, a serial number and the ICC-ES PMG listing which will be located on a label inside the mechanical room. A permanent sign, bearing the following statement, must be attached to the pumping equipment: Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they, to be construed as an endorsement of the subject of the Listing or a recommendation for its use. There is no warranty by LCC Evaluation Service, LLC, express or implied, as to R ik any finding or other matter in this listing, or as to any product covered by the listing. ■�� uae�run 1;11 :rut :.oar,cir Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 3 PMG-1619 I Most Widely Accepted and Trusted Page 2 of 3 Installation: Models: Notice: The pool shell is designed to remain full of water at all times. The shell may be damaged if the water level is allowed to drop below the skimmer. When appreciable draw -down is noticed or if it becomes necessary to drain the pool, contact Modpools Limited or its dealers for instructions. A permanent label must be attached adjacent to the above sign indicating the manufacturer's name, distributer's name, address and telephone number and the ICC-ES PMG listing mark. The prefabricated one-piece swimming pools must be permanently installed aboveground/onground, in -ground or semi-inground in accordance with this report and the manufacturer's published installation instructions. All plumbing and electrical installations must comply with the applicable codes in effect at the construction site. Electrical components are outside the scope of this report. Electrical components have been evaluated by another agency, QPS Evaluation Services Inc. Subject to the code official's approval, the prefabricated one-piece swimming pools may be installed without a soil investigation by a registered design professional, unless any of the following conditions is encountered at the site: 1. The existence of groundwater within the excavation, where the pool floor will contact the soil at the time of installation. 2. The existence of an uncompacted fill in contact with any portion of the pool or spa shell. 3. The existence of any expansive -type soils, unless the pool manufacturer has provided specific instructions regarding expansive soils within their installation instructions. 4. The existence of any soil types with an angle of repose that will not support the walls of the excavation at desired slopes. 5. Danger to adjacent structures posed by the proposed pool location. If any of the above conditions is encountered, excavation must cease immediately. The site conditions must then be reviewed, and recommendations made, by a registered design professional. The code official must approve the registered design professional's report before work is resumed. Details specifically for installations in expansive, clay, or adobe soils apply only when supported by the registered design professional's recommendations and approved by the code official. The pool excavation profile must coincide with the contours of the pool. The overexcavation is approximately 6 to 12 inches (152 to 305 mm) on the sides and ends. The overexcavation at the pool bottom is approximately 4 inches (102 mm). The backfill for the pool is a layer of minimum 3-inch- thick (76 mm) bedding sand matching the pool or spa profile. This sand layer is compacted using a manual tamper and water. The pool shell must sit firmly on compact gravel or concrete and be within 1 inch (25.4 mm) of level. Simultaneous waterfill and sand backfill operations then commence. The sand is compacted with a tamper and water. The installer must ensure that the backfill level and water level are approximately the same throughout the filling procedure. After completion of the backfill, the bond beam and decking must be installed in accordance with the manufacturer's published installation instructions, and as approved by the code official. The prefabricated one-piece swimming pools are permanently installed aboveground/onground, in - ground or semi-inground and are intended for recreational use as swimming pools in residential applications with water circulated through a filter in a closed system. The pools comply with either ANSI/APSP/ANSI-4 or ANSI/APSP/ANSI-5, as applicable as Type O pools. The overall dimensions, depths and capacities of recognized models are shown in Table 1. The prefabricated one-piece swimming pools consist of one-piece steel shipping container meeting ISO 1 CC and ISO/TC-104 specifications for standard steel dry cargo containers. Inner walls are factory lined with Primer 251 Part A and Part B and Concrete Solutions HP Urethane Resin by Rhino Linings- When applicable, Plexiglas Windows are standard acrylic molding conforming to ASTM D790 with minimum flexural strength Fb=16,000 psi and tensile strength Ft=10,500 psi. PMG-1619 I Most Widely Accepted and Trusted Page 3 of 3 Notice: The aboveground/onground models are designed to be placed on a leveled concrete floor or compact gravel and shall will never be installed inside the ground Notice: The pool shells are designed to remain full of water at all times. The shell may be damaged if the water level is allowed to drop below the skimmer. When appreciable draw -down is noticed or if it becomes necessary to drain the pool, Modpools Limited or its dealers should be contacted for instructions. Conditions of Listing: 1. The pool shells must be constructed and installed in accordance with this report and the manufacturer's published installation instructions. In the event of conflict, this report governs. 2. Electrical and plumbing installations must comply with the applicable codes in effect at the construction site at the time of construction. 3. Electrical components are outside the scope of this report. Electrical components have been evaluated by another agency, QPS Evaluation Services Inc. 4. Clearances of the pools from slopes set forth in IBC Section 1808.7, CBC Section 1808.7, CRC Section R403.1.7 or IRC Section R403.1.7 must be observed. 5. A barrier must be installed in accordance with IBC Section 3109, ISPSC Section 305, CRC Section AG105 or IRC Section AG105, as applicable. 6. Slip resistance is outside the scope of this evaluation report. Reports of slip resistance tests that demonstrate compliance with Section 8.1 of ANSI/APSP/ANSI-4 or APSP/ANSI-5, as applicable and must be submitted for approval by the code official. 7. The pools are classified as Type O pools: and therefore, are not intended for use with diving boards or other diving equipment. 8. Pools located in flood hazard areas established in accordance with Table R301.2(1) of the IRC must comply with Sections AG101.2 and AG103.3 of the IRC, Section AG101.2 of the CRC or Section 304 of the ISPSC. 9. Suction outlets must be designed and installed in accordance with IBC Section 3109.5, CBC Section 3137B, CRC Section AG106, ISPSC Section 310 and IRC Section AG106.1. 10. The prefabricated one-piece swimming pools are under a quality control program with surveillance inspections annually by ICC-ES. TABLE 1 POOL SIZES LENGTH (feeUinches) WIDTH (feeUinches) MAX. DEPTH (feeUinches) CAPACITY (gallons) POOL TYPE 12' X 8'3" 12'-6" 8'-3" 4W 1 /4" 2500 O 16' X 8'3" 16-0" 8'-3" 4'-7 1/4" 3300 O 20' X 8'3" 20'-0" 8'-3" 5'-2 3/4" 4800 O 20' X 11'6" 20'-0" 11'-6" 5'-2 3/4" 6800 O 40' X 87" 40'-2" 8'-7" 64 3/4" 9600 O 40' X 11'8" 40'-2" 11'-8" 5'-4 3/4" 13600 O For SI: 1 foot = 304.8 mm, 1 inch = 25.4 mm, 1 gallon = 3.785 liters.