APPROVED BLD BLD2024-0657+ARCHITECTURAL PLANS+5.15.2024_1.16.40_PM+4259429MINIMUM DESIGN LOADS: 2021 WA STATE RES CODE / 2021 IRC W/ AMENDMENTS SUNROOM CATEGORY II (PER 2021 IRC R301.2.1.1.1 & AAMA / NPEA / NSA 2100) NOTE: COMPONENTS HAVE BEEN CHECKED AGAINST DESIGN LOADS SHOWN & FOUND TO BE ACCEPTABLE STRUCTURALLY DEAD LOADS: 1. ROOF: 15 PSF 2. WALLS: 6 PSF �[e7Z�1110111M� 9[11]=00 ULTIMATE DESIGN WIND SPEED: 115 MPH, 3 SEC. GUSTS LIVE LOADS: ROOF: 40 PSF DEFLECTION LIMITS: WALLS: L/175 THIS THERMALLY ISOLATED SUNROOM IS UNCONDITIONED AND NOT HABITABLE NOTE: THE P.E. STAMP ON THESE DRAWINGS ADDRESS ONLY THE GDI MANUFACTURED COMPONENTS & THE ANCHORAGE OF THESE COMPONENTS TO THE EXISTING STRUCTURE. NOTES: 1. ALLVIEW (CA5) SUNROOM; WHITE IN COLOR 2. CONSTRUCT SUNROOM ON EXISTING CONCRETE AND UNDER EXISTING ROOF 3. NO ELECTRICAL BY GDI 4. CONCRETE A) CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301 SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. B) ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. EXTERIOR FLOORS AND EXPOSED CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AND 5% TO 7% AIR ENTRAINMENT. 5. WOOD A) MATERIALS - FRAMING LUMBER i) WOOD POSTS: NO. 2 GRADE (OR BETTER) SOUTHERN PINE OR DOUGLAS FIR ii) 2x8, 2x10, 2x12 NO.2 GRADE (OR BETTER) SOUTHERN PINE OR DOUGLAS FIR B) WOOD MEMBERS SHALL BE PRESSURE -TREATED FOR THE FOLLOWING CONDITIONS: i) IN DIRECT CONTACT WITH THE GROUND ii) SILLS OR PLATES ON CONCRETE WITHIN 8" OF FINISHED GRADE iii) JOISTS AND SUBFLOORS WITHIN 18" OF FINISH GRADE AND BEAMS WITHIN 12" OF FINISH GRADE iv) EXPOSED EXTERIOR DECKS C) FASTENERS ALL FASTENERS AND HARDWARE USED TO CONNECT TO PRESSURE TREATED WOOD MEMBERS SHALL EITHER BE 304 OR 316 STAINLESS STEEL, OR HOT DIPPED GALVANIZED PER ASTM-A653 COATING DESIGNATION G-185 AND ASTM-Al53 6. STRUCTURAL ALUMINUM A) ALL EXTRUSIONS SHALL BE COMMERCIAL GRADE ALUMINUM SUPPLIED BY GREAT DAY IMPROVEMENTS, LLC. B) ROOF PANELS SHALL BE 3" OR 6" THICK SUPER FOAM ROOF PANELS FACED WITH A 0.024" ALUMINUM SKIN TOP AND BOTTOM. 7. THIS SUNROOM IS CONSIDERED AS NON -CONDITIONED SPACE, EXEMPT FROM ENERGY REQUIREMENTS (PER 2021 IRC SECTION N1102.1, NOTE 1.2) GREAT DAY IMPROVEMENTS PATIO ENCLOSURES, SEATTLE VOELKER RESIDENCE SHFFT it nFSCRIPTInN 1 COVER 2 ELEVATION "B" WALL 3 ELEVATION "A" & "C" WALL 4 FLOOR PLAN 5 SYSTEM DETAILS Digitally signed by James A Clancy Reason: I am the author of this document Date: 2024.05.15 13:50:15-04'00' w CC w O w CC U H O CC / / w H m 2 O a z w O z 0 U Z W H EXISTING ROOF w TEMPERED GLASS x x w o 17" TRANSOM(S) % r o TEMPERED GLASS DOOR(S) i� W/ SCREEN(S) z TEMPERED GLASS DEADLITE(S) 83" 0 z 0 U z :::�� 215 1/2" EXISTING CONCRETE ELEVATION - "B" WALL w w O 1 Og WAStn f' a OHO w c� C SS'ONAL G 0 � a 0 DATE 5/13/24 DRAWN MTS KURT VOELKER 7904 203rd STREET SW , A, SEATTLE Great Day JAMESA. CLANCY, P.E., L.S. PROFESSIONAL ENGINEER LIC. #43543) a CD � 3635 S LAWRENCE ST SUITE A � (WA. (W SCALE 1/4" - 1' 0 SHEET EDMONDS, WA 98026 JOB #22010 TACOMA, WA 98409 Improvements 206-274-8287 601 ASBURY AVENUE NATIONAL PARK, NJ. 08063 o 2 OF 5 PH. # 856-853-7306 w CC w O w CC U H O CC w H EXISTING ROOF EXISTING ROOF m 2 O a z w O z 0 U Z W H o W TEMPERED GLASS w x TRANSOM(S) TEMPERED GLASS TRANSOM(S) 0 17 TEMPERED GLASS WINDOW(S) 17" 0 W/SCREEN(S) TEMPERED GLASS / TEMPERED GLASS DOOR(S) j/ TEMPERED GLASS DEADLITE(S) W/ SCREEN(S) 63" DEADLITE(S) Q 0 83" / 83" TEMPERED GLASS KNEEWALL(S) / o o 37" IL/J J. 0 z 111 7/8" EXISTING CONCRETE EXISTING CONCRETE 112" ¢ ELEVATION - "A" WALL ELEVATION - "C" WALL w w O 1 Og WAStn f' a OHO w CD C SS�ONALG 0 � a 0 DATE 5/13/24 DRAWN MTS KURT VOELKER 7904 203rd STREET SW SEATTLE , A, Great Day JAMESA. CLANCY, P.E., L.S. PROFESSIONAL ENGINEER LIC. #43543) a CD � 3635 S LAWRENCE ST SUITE A (WA. (W SCALE 1/4" - 1' 0" SHEET EDMONDS, WA 98026 JOB #22010 TACOMA, WA 98409 206 274 8287 Improvements 601 ASBURY AVENUE NATIONAL PARK, NJ. 08063 o 3 OF 5 PH. # 856-853-7306 :XISTING W ROOF SUPPORT POST TOTAL OF 2) FLOOR PLAN 1/4" DIA. GALV. LAG SCREWS STAGGERED @ 16" C/C; PROVIDE MIN. 1 1/2" THREAD ENGAGEMENT INTO STRUCTURAL FRAMING DBL. WALL EXPANDER #8xl/2" TEK SCREWS @ TOP, BOTTOM, 1/3rd UP & 1/3rd DOWN (INSIDE & OUT) #8xl" TEK SCREWS @ TOP, BOTTOM, 1/3rd UP & 1/3rd DOWN FLOOR EXPANDERJY MASTER FRAME JAMB PLAN VIEW OF MASTER FRAME JAMB & DBL. EXPANDER CONNECTION @ EXISTING WALL #8xl/2" TEK SCREWS (2) @ EACH GANGING (INSIDE & OUT) FLOOR EXPANDER 1/4" DIA.xl 3/4" TAPCON ANCHORS STAGGERED @ 16" C/C ALONG FLOOR EXPANDER BETWEEN UNIT GANGINGS MASTER FRAME SILL CONCRETE FOUNDATION d a. d 'y SECTION THROUGH MASTER FRAME SILL CONNECTION @ CONCRETE FOUNDATION TEMPERED GLAZIN( #8xl/2" TEK S( 1-LITE MALE MASTER FRAME HEAD SECTION THROUGH MASTER FRAME HEAD CONNECTION @ GLASS TRANSOM (2) #8xl/2" TEK SCREWS ATTACHING GANGING POST, MASTER FRAME, & FLOOR EXPANDER (INSIDE & OUT) MASTER FRAME JAMB-\ ANCHORING NOTES: 3/8" DIA. ANCHOR BOLTS 31/2" LONG GALV. LAG SCREWS INTO WOOD; 3" LONG DEWALT SCREW - BOLT+ INTO CONCRETE, SET CENTER OF ANCHORS AT LEAST 2" FROM EDGE OF SUPPORTING MATERIAL #8xl/2" TEK SCREWS @ / �MASTER FRAME JAMB UP - TOP, BOTTOM, 1/3rtl & 1/3rd DOWN FLOOR EXPANDER GANGING POST PLAN VIEW OF MASTER FRAME JAMBS CONNECTION @ GANGING POST TEMPERED GLASS GLAZING STOP 1-LITE FEMALE #8xl/2" TEK SCREWS (2) @ EACH GANGING CONCRETE FOUNDATION (INSIDE & OUT) FLOOR EXPANDER 1/4" DIA.xl 3/4" TAPCON ANCHORS STAGGERED @ 16" C/C ALONG FLOOR EXPANDER BETWEEN UNIT GANGINGS SECTION THROUGH GLASS KNEEWALL CONNECTION @ CONCRETE FOUNDATION EXISTING WOOD FRMING A SILICONE SEALANT SILICONE SEALANT #10x2" PANEL-TITE TRISEAL WOOD 1-LITE MALE SCREWS @ 1& /CZ -- TEMPERED GLAZING STOP GLASS SECTION THROUGH GLASS TRANSOM CONNECTION @ EXISTING HEADER FLOOR EXPANDER MASTER FRAME JAMB WOOD POST OB #10x2" PANEL-TITE TRISEAL / / WOOD SCREWS @ TOP, BOTTOM, 1/3 UP & 1/3 DOWN FLOOR EXPANDER PLAN VIEW OF MASTER FRAME JAMBS CONNECTION @ WOOD POST MASTER FRAME SILL #8xl/2" TEK SCREWS @ 18" C/C TOP RAIL WILL WITHSTAND A SINGLE CONCENTRATED LOAD OF 200 LBS 1-LITE MALE TEMPERED GLASS GLAZING STOP SECTION THROUGH MASTER FRAME SILL CONNECTION @ GLASS KNEEWALL EXISTING WOOD FRAMING SILICONE SEALANT) SILICONE SEALANT MASTER FRAME #10x2" PAN EL-TITE HEAD TRISEAL WOOD SCREWS @ 18" C/C SECTION THROUGH MASTER FRAME HEAD CONNECTION @ EXISTING HEADER