Loading...
REVIEWED BLD2023-1587+MANUF SPECS+12.11.2023_9.30.49_AM+3944409BLD2023-1587 RECEIVED CITY OF EDMONDS • • • DEVELOPMENT SERVICES AMST SERIES DEPARTMENT Air Conditioning & Heating REVIEWED BY CITY OF EDMONDS Product Features • Internal factory -installed thermal expansion valves for cooling and heat pump applications • Direct drive, multi -speed ECM blower motor • All -aluminum evaporator coil • Coil mounting track for quick repositioning • Optimized for use with R-410A refrigerant • Cabinet air leakage less than 2.0% at 1.0 inch H2O when tested in accordance with ASHRAE standard 193 • Cabinet air leakage less than 1.4% at 0.5 inch H2O when tested in accordance with ASHRAE standard 193 • AHRI certified; ETL listed MULTI -POSITION, MULTI -SPEED, ECM -BASED AIR HANDLER WITH INTERNAL TXV 1'2 TO 5 TONS Contents Air Handler Nomenclature........ Heater Kit Nomenclature.......... Product Specifications ............... Dimensions................................ Airflow Data ............................... Heat Kit Data .............................. Wiring Diagram .......................... Accessories ................................ • Rigid SmartFrameT' cabinet • Horizontal or vertical configuration capabilities • 21" depth for easier attic access • DecaBDE-free thermoplastic drain pan with secondary drain connections • Screw -less sides and back helps to reduce con- densation when installed in humid locations • Foil -faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grain -embossed finish • Glue -less cabinet insulation retention • Tool -less filter access • Field Installed 3 kW — 25 kW electric heater kits available 10 PARTS * ETV t,s LIMITED COMITY'SY E COMPANY WITH GUALITV SYSTEM ENVIRONMENTAL SYSTEM YEAR WARRANTY' I CERTIFIED BY DNV OIL CERTIFIED BY DNV GL Intertek =ISO 9001==lso,aoo,= Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. 2 2 3 4 5 7 9 ....... 12 BBB SS-GAMST www.goodmanmfg.com 06/22 NOMENCLATURE A M S T 36 B U 1 4 05 A 1 2 3 4 5,6 7 8 9 10 11,12 13,14 Product A Corporate Air Handler D Daikin Air Handler Unit Application C Ceiling Mount M Multi -Positional W Wall Mount F Fit Compatible Multi -Positional H Horizontal Discharge Compatible Multi -Positional Motor S MS -ECM V VS -ECM Communicating Expansion Device E Electronic Expansion Valve F Flowrator T Thermal Expansion Valve Nominal Capacity Range Engineering * Major/Minor Revisions A -Initial Release B - 1st Revision Electric Heat KW 5=5kw 8=8kw 10 = 10kw Refrigerant 3 - R32 4 - R410A 6 - R410A or R22 Electrical 1 208/240 V, 1 Phase, 60 Hz Cabinet N - Uncased P - Painted U - Unpainted Cabinet Width 12 = 1 Ton 36 = 3.0 Tons AC* Series AM* Series AW* Series 18=1.5Tons 42=3.5Tons M=43.25" B=17.5" S=20.2" 24=2.0Tons 48=4.0Tons L=49.25" C =21.0" L=24.0" 30=2.5Tons 60=5.0Tons D =24.5" *DENOTES AHRI WILD CARDS HKS X 03 X A AA 1 2 Unit Type HKS Heat Kit for Air Handlers Circuit Breaker X No circuit breaker C Circuit Breaker Heating Capacity @ 240 Volts 3 4 03 3.0 kW 15 14.4 kW 05 4.5 kW 19 19.2 kW wth 150F limit 06 6.0 kW 20 19.2 kW with 170F limit 08 8.0 kW 25 25.0 kW 10 9.6 kW 5 6,7 Revisions Engineering Revisions Phase A Single Phase 208 V E Three Phase 240 V B Single Phase 240 V F Three Phase 208/240 V C Single Phase 208/240 V G Three Phase 460 V D Three Phase 208 V H Special case 208 V Cabinet Size (MAX) C C Cabinet D D Cabinet X All Cabinet Sizes 2 www.goodmanmfg.com SS-GAMST PRODUCT SPECIFICATIONS I: :D .0D NOMINAL RATINGS 760,000 Cooling (Btu/h) 24,000 36,000 36,000 36,000 42,000 48,000 48,000 BLOWER Diameter 10" 10" 10" 10" 10" 10" 10" 11" Width 6" 6" 6" 8" 8" 10" 10" 10" COIL CONNECTIONS Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction 3/4" 3/4" 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" Coil Drain Connect(FPT) 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" ELECTRICAL DATA Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity 5.8/5.8 5.6/5.6 5.6/5.6 7.1/7.1 5.9/5.9 7.1/7.1 8.6/8.6 8.6/8.6 Max. Overcurrent Device 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 (Amps) Minimum VAC 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 253 Blower Motor Full Load Amps (FLA) 4.6 4.5 4.5 5.7 4.7 6.9 6.9 6.9 Horsepower (HP) SHIP WEIGHT (LBS.) 112 129 129 153 153 153 155 167 *Airflow rate @.3 static Note: Assumes dry coil; SUM correction for wet coil = 4% (208V / 240V) SS-GAMST www.goodmanmfg.com DIMENSIONS 7 3/18" 5/8' (1.59 cm) —(1 B I— 5M' (1.59 cm) G — SEE HORIZONTAL DRAIN PORT DETAI� 10 3/16' (25.88 cm) SEE VERTICAL DRAIN PORT DETAIL 1 13116" (4.60 co) cm) n) 9 1/4' (23.50 cm) 7 1/2" (19.05 cm) 51/8" (13.02 cm) 31B" (7-94 cm) 1 3/8' (3.49 cm) - 1 1 3/4" (4.45 cm) 2 11/16" (6.83 cm) 1 3(4' (4.45 cm) SUCTION TUBE LIQUID LINE ° 1 INLET TUBE — INLET (FRONT VIEW) 1 13/16" (4.60 cm) 11 5116" (28.73 cm) 12' (1.27 cm) 1" (2.54 cm) —I I.— 19.5" (49.53 cm) I— 9/16 (1.43 cm) INLET (RIGHT SIDE VIEM 4 1/2" (11.43 cm) 1 50' (4.13 cm) 1 5/16" (3.33 cm) HORIZONTAL DRAIN PORT DETAIL 31/16" (7.78 cm) e 2 15/16' (7.46 cm) e 3 3/4" (9.53 cm) 1 5/8" (4.13 cm) VERTICAL DRAIN PORT DETAIL AMST24BU 445 16 5/16 17 9/16 15 1/4 12 12 1/2 9 12 9/16 2 13 5/8 AMST30BU* 53 7/16 16 5/16 17 9/16 23 11/16 20 1/16 12 1/2 9 12 3/4 2 13 5/8 AMST36BU* 53 7/16 16 5/16 17 9/16 23 11/16 20 1/16 12 1/2 9 12 3/4 2 13 5/8 AMST36CU* 49 19 13/16 21 1/8 21 12/16 17 3/4 16 1/16 9 12 3/4 2 17 1/8 AMST42CU* 53 7/16 19 13/16 21 1/8 21 12/16 18 1/2 16 1/16 9 12 3/4 2 17 1/8 AMST48CU* 58 1913/16 211/8 263/16 2215/16 1410/16 1013/16 613/16 2 171/8 AMST48DU* 53 7/16 23 1/14 24 5/8 21 1/16 18 1/4 17 11/16 12 9/16 615/16 2 20 5/8 AMST06DU* 58 23 1/14 24 5/8 26 22 3/4 17 11/16 12 9/16 13 3/16 2 20 5/8 4 www.goodmanmfg.com SS-GAMST AIRFLOW DATA ..STATIC PRESSURE (IN T1 720 690 625 605 525 W.C) 505 385 370 265 T2 850 825 770 750 675 665 590 575 470 T3 900 875 830 815 750 740 670 655 550 T4 11030 1,005 960 950 900 890 825 820 760 AMST 24BU1400AA T5 825 800 745 730 660 645 560 550 460 T6 935 910 865 850 790 780 715 705 620 T7 1,100 1,080 1,035 1,020 970 960 902 900 840 T8 1,045 1,025 985 970 920 910 820 845 785 T9 1,215 1,195 1,155 1,145 1,105 1,095 1,045 1,040 980 T1 750 725 670 655 585 570 465 455 360 T2 920 895 845 830 780 770 710 700 615 T3 985 960 915 900 850 40 785 775 710 T4 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960 AMST 30BU1400AA T5 1,070 1,050 1,005 995 945 935 890 885 830 T6 620 585 515 458 375 310 260 245 145 T7 840 815 760 745 685 670 590 580 480 T8 855 830 780 765 705 695 625 615 515 T9 995 970 925 910 860 850 800 790 730 T1 750 725 670 655 585 570 465 455 360 T2 920 895 845 830 780 770 710 700 615 T3 985 960 915 900 850 840 785 775 710 T4 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960 AMST 36BU1400AA T5 1,070 1,050 1,005 995 945 935 890 885 830 T6 620 585 515 485 375 310 260 245 145 T7 840 815 760 745 685 670 590 580 480 T8 855 830 780 765 705 695 625 615 515 T9 995 970 925 910 860 850 800 790 730 T 1 1,120 1,085 1,020 1,000 910 890 770 760 680 T2 1,285 1,255 1,190 1,170 1,100 1,085 990 980 885 T3 1,430 1,400 1,345 1,330 1,260 1,250 1,175 1,165 1,065 T4 1,735 1,410 1,660 1,645 1,580 1,570 1,510 1,500 1,440 AMST 36CU1400AA T5 1,830 1,805 1,755 1,740 1,685 1,675 1,605 1,595 1,525 T6 1,165 1,130 1,055 1,035 960 940 825 815 715 T7 1,450 1,425 1,370 1,355 1,285 1,275 1,200 1,190 1,095 T8 1,070 1,035 960 935 830 810 700 690 610 T9 1,560 1,530 1,470 1,455 1,390 1,380 1,310 1,300 1,235 T1 1,165 1,140 1,085 1,065 990 975 895 880 765 T2 1,210 1,185 1,130 1,110 1,040 1,025 950 935 830 T3 12,515 1,190 1,135 1,120 1,055 1,040 960 945 835 T4 1,495 1,470 1,425 1,415 1,365 1,355 1,305 1,295 1,220 AMST 42CU1400AA T5 1,435 1,410 1,360 1,345 1,295 1,285 1,220 1,210 1,140 T6 1,410 1,385 1,335 1,325 1,280 1,270 1,195 1,185 1,115 T7 1,440 1,415 1,362 1,355 1,305 1,295 1,235 1,225 1,155 T8 1,230 1,205 1,150 1,135 1,070 1,060 990 975 850 T9 1,495 1,470 1,425 1,415 1,365 1,355 1,305 1,295 1 1,220 SS-GAMST www.goodmanmfg.com AIRFLOW DATA (CONT.) MODEL T1 1,165 0,310 1,235 1,220 1,135 1,125 1,050 T2 1,210 7-7 0, 470 1,400 1,390 1,315 1, 305 1,230 T3 1,215 1,560,545 1,480 1,470 1,400 1,390 1,315 T4 1,495 1,640 1,560 1,550 1,485 1, 475 1,410 AMST 48CU1400AA T5 1,435 1,795 1,750 1,735 1,680 1,670 1,605 1,595 1,525 T6 1,410 1,435 1,375 1,355 1,280 1,265 1,165 1,155 1,065 T7 1,440 1,700 1,650 1,635 1,570 1,560 1,495 1,485 1,420 T8 1,230 1,730 1,680 1,665 1,595 1,585 1,515 1,505 1,425 T9 1,495 1,295 1,230 1,210 1,130 1,115 1,025 1,015 930 T1 1,425 1,395 1,335 1,320 1,250 1,240 1,165 1,155 1,070 T2 1,510 1,480 1,425 1,410 1,345 1,335 1,270 1,260 1,185 T3 1,605 1,580 1,525 1,510 1,450 1,440 1,375 1,365 1,300 T4 1,875 1,855 1,810 1,795 1,735 1,725 1,670 1,665 1,605 AMST 48DU1400AA T5 1,755 1,730 1,680 1,665 1,605 1,595 1,535 1,525 1,465 T6 1,350 1,320 1,260 1,245 1,175 1,160 1,085 1,075 980 T7 1,140 1,105 1,040 1,020 935 915 805 790 685 T8 1,605 1,580 1,525 1,510 1,450 1,440 1,375 1,365 1,300 T9 1,605 1,580 1,525 1,510 1,450 1,440 1,375 1,365 1,300 T1 1,215 1,175 1,095 1,070 975 950 790 780 700 T6 1,815 1,785 1,725 1,710 1,650 1,640 1,570 1,560 1,490 AMST 60DU1400AA T7 1,360 1,325 1,250 1,230 1,145 1,125 1,010 990 850 T8 2,070 2,045 1,995 1,980 1,930 1,920 1,855 1,845 1,785 T9 1,970 1,945 1,895 1,880 1,815 1,805 1,740 1,730 1,600 Noies 1. Airflow data indicated is at 230V without air filter in place. 2. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. 3. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations 4. When applying a humidistat (normally closed), refer to the installation and operating instructions. The humidistat can adjust the cooling airflow to 85%. Horizontal Left Factor 0.98 Horizontal Right Factor 0.95 Downflow Factor 0.96 See notes on page 7. www.goodmanmfg.com SS-GAMST HEAT KIT DATA 7AMST224BU1407OAA 0/0 5.8/5.8 15/15 10.8/12.5 19/21.4 20/25 HKS*05XC* 17.3/20 27/30.8 30/35 HKS*06XC* 21.7/25 32.8/37 35/40 HKS*08XC* 28.9/33.3 41.9/47 45/50 HKS*10XC* 34.7/40 49.1/56 50/60 HKSC15XA208 34.7 49.1 50 17.3 21.7 25 70.8 80 HKSC15XB 240 40 55.8 60 20 25 25 80.8 90 AMST30BU1400AA 0/0 5.6/5.6 15/15 HKS*03XC* 10.8/12.5 19/21.3 20/25 HKS*05XC* 17.3/20 27/30.6 30/35 HKS*06XC* 21.7/25 32.7/37 35/40 HKS*08XC* 28.9/33.3 42/47.3 45/50 HKS*10XC* 34.7/40 49/55.6 50/60 HKSC15XA208 34.7 49 50 17.3 21.7 25 70.8 80 HKSC15XB 240 40 55.6 60 20 25 25 80.8 90 AMST36BU1400AA 0/0 5.6/5.6 15/15 HKS*03XC* 10.8/12.5 19/21.3 20/25 HKS*05XC* 17.3/20 27/30.6 30/35 HKS*06XC* 21.7/25 32.7/37 35/40 HKS*08XC* 28.9/33.3 42/47.3 45/50 HKS*10XC* 34.7/40 49/55.6 50/60 HKSC15XA208 34.7 49 50 17.3 21.7 25 70.8 80 HKSC15XB 240 40 55.6 60 20 25 25 80.8 90 AMST36CU1400AA 0/0 7.1/7.1 15/15 HKS*03XC* 10.8/12.5 20.7/23 25/25 HKS*05XC* 17.3/20 29/32.1 30/35 HKS*06XC* 21.7/25 34/38.4 35/40 HKS*08XC* 28.9/33.3 43/48.8 45/50 HKS*10XC* 34.7/40 50.5/57 60/60 HKS*15XF* 0/0 7.1/7.1 15/15 30/34.6 30/34.6 40/45 HKSC15XA 208 34.7 50.5 60 17.3 17.3 25 72.1 80 HKSC15XB 240 40 57.1 60 20 20 25 82.1 90 HKSC19CH 208 34.7 50.5 60 34.7 34.7 45 93.9 100 HKSC19CB240 40 57.1 60 40 40 50 107 110 AMST42CU1400AA 0/0 5.9/5.9 15/15 HKS*03XC* 10.8/12.5 19/21.5 20/25 HKS*05XC* 17.3/20 28/30.9 30/35 HKS*06XC* 21.7/25 33/37.1 35/40 HKS*08XC* 28.9/33.3 42/47.5 45/50 HKS*10XC* 34.7/40 49/55.9 50/60 HKS*15XF* 0/0 5.9/5.9 15/15 30/34.6 38/43 40/45 HKSC15XA208 34.7 49.2 50 17.3 21.7 25 70.9 80 HKSC15XB 240 40 55.9 60 20 25 25 80.9 90 HKSC19CA 208 34.7 49.2 50 34.7 43.3 45 92.5 100 HKSC19CB 240 40 55.9 60 40 50 50 106 110 See notes on page 8. SS-GAMST www.goodmanmfg.com HEAT KIT DATA (CONT.) AMST48CU1400AA 0/0 7.1/7.1 15/15 HKS*03XC* 10.8/12.5 20.7/23 25/25 HKS*05XC* 17.3/20 29/32.1 30/35 HKS*06XC* 21.7/25 34/38.4 1 35/40 HKS*08XC* 28.9/33.3 43/48.8 45/50 HKS*10XC* 34.7/40 50.5/57 60/60 HKS*15XF* 0/0 7.1/7.1 15/15 30/34.6 38/43 40/45 HKSC15XA208 34.7 50.5 60 17.3 21.7 25 72.1 80 HKSC15XB 240 40 57.1 60 20 25 25 82.1 90 HKSC19CH 208 34.7 50.5 60 34.7 43.3 45 93.9 100 HKSC19CB240 40 57.1 60 40 50 50 107 110 AMST48DU1400 0/0 8.6/8.6 15/15 HKS*03XC* 10.8/12.5 22/24.3 25/25 HKS*05XC* 17.3/20 30.3/34 35/35 HKS*06XC* 21.7/25 36/39.9 40/40 HKS*08XC* 28.9/33.3 45/50.3 45/60 HKS*10XC* 34.7/40 52/58.6 60/60 HKS*15XF* 0/0 8.6/8.6 15/15 30/34.6 38/43 40/45 HKSC15XA208 34.7 52 60 17.3 21.7 25 73.6 80 HKSC15XB 240 40 58.6 60 20 25 25 83.6 90 HKS*20XF* 0/0 8.6/8.6 15/15 37.5/43.3 47/54 50/60 HKSC20DA208 34.7 52 60 34.7 43.3 45 95.3 100 HKSC20DB 240 40 58.6 60 40 50 50 109 110 AMST60DU1400 0/0 8.6/8.6 15/15 HKS*03XC* 10.8/12.5 22/24.3 25/25 HKS*05XC* 17.3/20 30.3/34 35/35 HKS*06XC* 21.7/25 36/39.9 40/40 HKS*08XC* 28.9/33.3 45/50.3 45/60 HKS*10XC* 34.7/40 52/58.6 60/60 HKS*15XF* 0/0 8.6/8.6 15/15 30/34.6 38/43 40/45 HKSC15XA208 34.7 52 60 17.3 21.7 25 73.6 80 HKSC15XB 240 40 58.6 60 20 25 25 83.6 90 HKS*20XF* 0/0 8.6/8.6 15/15 37.5/43.3 47/54 50/60 HKSC20DH 208 34.7 52 60 34.7 43.3 45 95.3 100 HKSC20DB 240 40 58.6 60 40 50 50 109 110 HKTSD25DA208 52 73.6 80 35 43.3 45 117 125 HKTSD25DB 240 60 83.6 90 40 50 50 134 150 'Minimum Circuit Ampacity (Heater Amps+ Motor Amps) X1.25 2Maximum Overcurrent Protection = 2.25 X Motor Amps+ Heater Amps ACircuit 1: Single-phase for Air Handlers Circuit 2: Three-phase for HKR3 Heater Kits ---indicates Not Required Note: The 208 or 240 in the heat kit part number field is for clarification of the nominal voltage for this model. HEATING KW CORRECTION FACTOR SUPPLY VOLTAGE CORRECTION FACTOR Multiply the 240-volt heating capacity by correction factors. www.goodmanmfg.com SS-GAMST CG CG G 0 0 0 Q 3 7 3 0 3 — BK GRD EOUIPMENTGROUND _ SEE NOTES 2 & 6 � USE COPPER WIRE TB R C I G I Wi I W2 I Y1 I Y2 101 CH 11121314 15 1 2 O qO O O 7O 8O O PLF RD PLM 1 2 O 4 5 6 7O BO O GR BK RD BL BR WH SEE NOTE BR WH RD or PU CR BK RD JRD K WH q C 1 2 3 A e5 4 B BL BL L RD or BK COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75' C FIELD WIRE IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. NOTES 1. RED W IRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3. "CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL7 OF CR(TERMINAL 4 OF ALTERNATE) RELAY TO APPROPRIATE TAP AT TB" 4. BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. 5. FUSE: 3A, 250V, 3AG ATO STYLE FUSE. OPTIONAL FUSE 3 AMP CARTRIDGE. 6. LOW VOLTAGE FIELD WIRING TO BE N.E.0 CLASS 2 WIRES. NOTE1 240 TR BL— FUSE RD I FU WH PU 5 OR BR YL 2 4 1 2345 CR EM C N BL ALTERNATE HEAT RELAY PU 4 WH RD GR BL BL ALTERNATE CONTROL RELAY COMPONENT CODE WIRING CODE COLOR CODE CR—CONTROL RELAY FACTORY WIRING BK—BLACK EM— EVAPORATOR MOTOR HIGH VOLTAGE RD —RED LOW VOLTAGE YL —YELLOW FL— FUSE LINK FIELD W IRING BL —BLUE PLF— FEMALE PLUG CONNECTOR HIGH VOLTAGE — GR —GREEN PLM— MALE PLUG CONNECTOR LOW VOLTAGE — PU —PURPLE R— RELAY SR —BROWN WH —WHITE TB— TERMINAL BOARD TR— TRANSFORMER YL TL— THERMAL LIMIT GRND— GROUND 0140A00761-A Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power refer to the wiring diagram on the Q WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. % unit for the most up-to-date wiring. 0 M O O IZ 3 Dl 7 3 dEr n O 3 GR SEE NOTES 2 & 6 GRID NE:h EQUIPMENT GROUND L17-7] ly USE COPPER WIRE WH Li _ BR PU YL 2 3 4 5 PLF 1 2 O qO O O O O O TB I R I C I G I W1 I W2 I Y1 I Y2 101 DH I1 PLM 1 2 O 4 5 6 O O O BK RD BL SR WH SEE NOTE BR I RD or BL COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. NOTES' 1. RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3. "CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL7 OF CR(TERMINAL 4 OF ALTERNATE) RELAY TO APPROPRIATE TAP AT TB" 4. BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY, 5. FUSE: 3A, 250V, 3AG ATO STYLE FUSE. OPTIONAL FUSE 3 AMP CARTRIDGE. 6. LOW VOLTAGE FIELD WIRING TO BE NEC CLASS 2 WIRES. 1 - BL RD BK L EM SEE NOTES 2 & 6 COMPONENT CODE WIRINGCODE COLOR CODE CR— CONTROL RELAY FACTORY WIRING BK —BLACK EM— EVAPORATOR MOTOR HIGH VOLTAGE RD —RED FL— FUSE LINK LOW VOLTAGE FIELDWIRING YL —YELLOW BL—BLUE PLF— FEMALE PLUG CONNECTOR HIGH VOLTAGE GR —GREEN PLM— MALE PLUG CONNECTOR LOW VOLTAGE — PU —PURPLE R— RELAY BR —BROWN WH —WHITE TB —TERMINAL BOARD TR— TRANSFORMER TL— THERMAL LIMIT GRND— GROUND Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram the unit for the most up-to-date wiring. Q WARNING sources maybe present. Failure to do so may cause property damage, personal injury, or death. 7 wiring. NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL CUIT1 H 208.240V THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT ftK COMBINATION ON THIS UNIT'S SERIAL PLATE. RDA AFTER INSTALLING OPTIONAL HEATER KIT, MARK AN "X" IN THE BOX ON THE SERIAL PLATE CORRESPONDING TO THE HEATER KIT USED. NO MARK INDICATES NO HEATER KIT INSTALLED. r K: I 3 IRCUIT 2 ` PH. 208-240V NOTE: - THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION FL HTRI 15K BK� BK BK I MI I BK PU I M7 In I BR 17 BL 40 VA TRAVSFORIIER, SEE ROTE L 230 VAC 3 208 VAC 24 vAC COMill CODE HIR—HEAT ELEMENT EM_EVAPORATORMOTOR ESTOR-ELEC BLOWER TIME DELAY RELAY ASRELAY.SEOGENCER _ RC RUN CAPACITOR TO. —THERMAL LIMIT TR _TRANSFORMER TO _TERMINAL BLOCK CC _CONTACTOR PC _941IN CONNECTOR SR STRAIN RELIEF FL _FUSE LNK CO _COFKVIT BREAKER WIRING CODE HIGH VOLTAGE LOW VOLTAGE Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram on the Q WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. % unit for the most up-to-date wiring. N N COLOR CODE SK BLACK Bk. BLLIE BR BROWN OR GREEN OR ORANGE PK PINK Pu PURP E RD RF D Vill 1W1IIt It YI IIUV! ACCESSORIES DOWNFLOW KITS D AMST24BU1400** i AMST48CU1400** AMST30BU1400** AMST48DU1400** AMST36BU1400** AMST60DU1400** AMST36CU1400** AMST42CU 1400* * HIGH HUMIDITY KIT 7AMST30B7U1400** 7A376CU1400**42CU1400** O00. AMST48DU1400** O00 AMST60DU1400** AMST36BU1400** AMST48CU1400** rfr•_JjjjMj�j'ArrV►Vr_AVj A -re ►�►�►�rrar 11 11 • AMST24BU1400** AMST30BU1400** LAI1011yi AMST48CU1400** AMST36CU1400** AMST36BU1400** AMST48DU1400** AMST42CU1400** AMST60DU1400** FILTERS 7D B ALFH16201E 16.0" x 20.0" C ALFH1912201E 19.5" x 20.0" ALFH2O231E 23.0" x 20.0" SINGLE POINT WIRING KIT (SPW-01) �•� HKSC15XB-240V •rr- AMST24BU1400** AMST30BU1400** AMST36BU1400** •rr AMST36CU1400** AMST42CU1400** AMST48CU1400** •rr- � AMST48DU1400** AMST60DU1400** HKSC15XA-208V HKSC19CA-208V H KSC19CB-240V HKSC20DA-208V AMST48DU1400** AMST60DU 1400* * H KSC20DB-240V HKSC25DA-240V AMST60DU1400** HKSC25DA-208V HKSC25DA Our continuing commitment to quality products may mean a change in specifications without notice. ©2022 OAIKINCOMFORT TECHNOLOGIES MANUFACTURING. L.P. • Houston, Texas • Printed in the USA 12 www.goodmanmfg.com SS-GAMST