REVIEWED BLD2023-1587+Manufacturer_Specifications_and_Installation_Instructions+12.11.2023_9.30.22_AM+3944407Or DA/K/N RECEIVED
Submittal Data Sheet Dec 11 2023
4 Ton HP, 14 SEER, 3 Phase 208/230V CITY OF EDMONDS
DEVELOPMENT SERVICES
DZ14SA0483 DEPARTMENT
STANDARD FEATURES
• R-410A chlorine -free refrigerant
• Energy -efficient scroll compressor
• Low-pressure switch
• Liquid refrigerant return protection
• Factory -installed, bi-flow Liquid -line filter drier
• Service valves with sweat connections and easy -access gauge ports
• Copper tube/enhanced aluminum fin coil
• Reliable time -initiated, temperature -terminated defrost control
• Contactor with lug connection
• Ground lug connection
• Units meet the performance outlined in Table 6.8.1-2 of ASHRAE Standard
90.1-2013
• AHRI Certified
• ETL Listed
• Innovative sound control top design
• Steel louver coil guard
• Heavy -gauge galvanized -steel cabinet
• Attractive Nickel Gray powder -paint finish
• Top and side maintenance access
• Service ports and controls are accessible while unit is operating
• When properly anchored, meets the 2010 Florida Building Code unit
integrity requirements for hurricane -type winds (Anchor bracket kits
available.)
REVIEWED
BY
CITY OF EDMONDS
" ERTFk
C(T S
�iSTED
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 9/28/2018 4:38:49 AM Page 1 of 3
r DA IKIN
Submittal Data Sheet
4 Ton HP, 14 SEER, 3 Phase 208/230V
DZ14SA0483
Outdoor Unit Model No.
Rated Cooling Conditions:
Max/Min Cooling Capacity (Btu/hr):
DZ14SA0483
Indoor ff DB/WB): 80 / 67
Ambient ff DB/WB): 95 / 75
* Rated Cooling Capacity (Btu/hr): 45,000
* EER: 11.50
* SEER:
Power Supply (V/Hz/Ph):
14.00
208/230 / 60 / 3
Min. Circuit Amps MCA (A): 18.7
Max Overcurrent Protection (MOP) (A): 30
Max Starting Current MSC(A): 15.40
Rated Load Amps RLA(A):
15.4
Refrigerant Type:
R-410A
Holding Refrigerant Charge (lbs):
133
Additional Charge (lb/ft):
0.05
Pre -charge Piping (Length) (ft):
15
Max. Pipe Length (Total) (ft):
200
Net Weight (lb):
Dimensions (HxWxD) (in):
235
34-1/4 x 29 x 29
Outdoor Unit Name: 4 Ton HP, 14 SEER, 3 Phase 208/230V
Rated Heating Conditions: Indoor ff DB/WB): 80 / 67
Ambient (*F DB/WB): 95 / 75
Max/Min Heating Capacity (Btu/hr): 44,500 / 28,000
* Rated Heating Capacity (Btu/hr):
* Heating COP: 3.9
* HSPF: 8.5
Compressor Type
Airflow Rate (High) (CFM):
1555
Suction Valve Connection Size (inch):
1-1/8
Liquid Valve Connection Size (inch):
3/8
Sound Pressure (High) (dBA):
76
Cooling Operation Range (*F DB):
65 - 115
Heating Operation Range (OF WB):
-10 - 65
Max. Pipe Length (Vertical) (ft):
200
Min. Cooling Range w/Baffle ff DB):
55
Min. Heating Range w/Baffle (°F DB): -5
Gross Weight (lb): 240
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 9/28/2018 4:38:49 AM Page 2 of 3
V
Submittal Data Sheet
4 Ton HP, 14 SEER, 3 Phase 208/230V
DZ14SA0483
DIMENSIONAL DRAWING
SA0363A* 29 29 32%
SA0364A*
29
29
32%
SA0483A*
29
29
34%
SA0484A*
29
29
34%
SA0603A*
35%
35%
34%
SA0604A*
35%
35%
34%
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinao.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 9/28/2018 4:38:49 AM Page 3 of 3